Geely Emgrand X7. Manual part - 426

 

  Главная      Geely     Geely Emgrand X7 - Manual

 

поиск по сайту            

 

 

 

 

 

 

 

 

 

 

 

 

содержание   ..   421  422  423  424  425  426  427  ..

 

 

Geely Emgrand X7. Manual part - 426

 

 

 

12 

Lamplet (+) 

0.3L 

Input 

+12v DC signal 

13 Ground 

0.3B 

Output GND 

DC 

signal 

14 Ground 

0.3B 

Output GND 

DC 

signal 

15 - 

16 - 

17 - 

18 - 

19 - 

20 - 

21 

Speed signal 

0.3Y/G 

Input 

Pulse signal 

22 

Rear defrost signal 

0.3O 

Input 

A627 A628 DC signal 

23 

Ignition switch 2 

0.3R/G 

Input 

A627 A628 DC signal 

8.2.7.4 Data flow table 

Serial 
Number 

Description 

Range of data 

1 Inside 

Temperature 

Sensor 

-40℃- 80℃ 

Outside Temperature Sensor 

-40℃- 80℃ 

3 Evaporator 

temperature 

sensor 

-40℃- 80℃ 

Heater temperature sensor 

-40℃- 80℃ 

5 Sunlight 

sensor 

0W-W 

Temperature regulating motor 

0%-100% 

Air Direction Adjusting Motor 

0%-100% 

Inside and outside circulation motors 

Inside/outside 

Backlight adjustment 

PWM signal.0%-100% 

10 Compressor 

control 

On/Off 

11 Rear 

defrost 

control 

On/Off 

12 Vehicle 

speed 

signal 

0-255Km/h 

13 Blower 

voltage 

0-16.5V 

14 Battery 

voltage 

0-18.5V 

 

1703

 

 

8.2.7.5 Controller self-inspection testing 

The ignition switch is turned from the gear OFF to the gear ON. 

 

 

Continuously press the "Circulated Air" switch 4 times within 2 seconds when the "OFF" switch is 
pressed. 

 

 

Start self-inspection testing after the LCD backlight flickers 3 times. 

 

 

Self-inspection item, 

 

 

 

 

Self-inspection item, 

A. For replacement of the A/C control module, see "8.2.8.1 replacement of A/C control module". 

Does the blower operate normally? 

 

 

Control A/C , 

1.  During self-inspection function running, data display area is the position to set teperature displaying, while 

other positions are "OFF" status. 

2.  During running of self-inspection function, A/C is controlled to be "OFF" status. 

3.  During self-inspection function running, the set temperature display position will be shown at every 0.5s and 

then fault code will be shown. 

4.  In the self-inspection test, keep the MODE characters in the previous state but do not run them. 

5.  When the vehicle is in the IGN2 OFF ON mode during the self-inspection testing, the vehicle will return to 

the OFF mode. 

6.  The display in the continuous operation mode is as follows: 

– 

Normal condition or fault condition last for 1h: 

Next 

Next 

Press the A/C 

switch. 

Press the "OFF" 
switch. 

Go to step 6 

Press the "OFF" 

switch. 

Next 

1704

 

NL08-2034b

显示

灯亮

0.5s

灯亮

熄灯

0.5s

 

– 

When it have many faults 

NL08-2035b

显示

故障1

故障2

故障N

故障1

......

 

8.2.7.6 DTC List 

Serial Number  Fault content 

Remarks: 

00 Normal 

 

11 

Open circuit of indoor temperature sensor 

 

12 

Short circuit of indoor temperature sensor 

 

13 

Ambient air temperature is short circuit 

 

14 

Ambient air temperature short circuit 

 

17 Evaporator 

sensor 

open 

 

18 

Evaporator sensor shorted 

 

19 

Short circuit or open circuit of driver-side temperature 
throttle motor 

20 

Driver-side temperature throttle motor is blocked. 

21 

Model air motor shorted or open 

In case the motor is unable to reach 
the specific location within 40s, it is 
judged as blocked. 

Display 

Light is 

“on” 

Light is 

“on” 

Lights out

Display 

Fault 1 

Fault 2 

Fault N 

Fault 1

1705

 

22 

Model air motor locked 

25 

In case the motor is unable to reach the specific 
location within 40s, it is judged as blocked. 

26 

Air inlet motor locked 

32 

Passenger side temperature motor shorted or open 

33 

Passenger side temperature motor locked 

8.2.7.7 Electrical Device Failure Relevance 

Serial 
Number 

Items Status 

Fault 

protection 

Inside Temperature 
Sensor 

Short circuit or open 
circuit 

Default temperature 25℃ 

2 Ambient 

air 

temperature 

Short circuit or open 
circuit 

Default temperature 20℃ 

Evaporator temperature 
sensor 

Short circuit or open 
circuit 

Default temperature -2℃ 

When the set temperature is 17℃-24.5℃, 
fix in the MAX COOL position. 

Temperature throttle 
motor 

Short circuit or open 
circuit 

When the set temperature is 25℃-32℃, fix 
in the MAX HOT position. 

Position surface-blowing mode: fixing in the 
surface-blowing mode 

Mode throttle motor 

Short circuit or open 
circuit 

Kept in the defrosting mode. 

Fresh air mode: fixed in the fresh air mode. 

Air intake valve motor 

Short circuit or open 
circuit 

Air returning mode: fixed in the air 
returning mode 

7 Sunlight 

sensor 

Short circuit or open 
circuit 

Default illumination 0 W/m2 

 