Geely Emgrand X7. Manual part - 49

 

  Главная      Geely     Geely Emgrand X7 - Manual

 

поиск по сайту            

 

 

 

 

 

 

 

 

 

 

 

содержание   ..  40  41  42  43  44  45  46  47  48  49  50  ..

 

Geely Emgrand X7. Manual part - 49

 

 

2.2.7.23 DTC P0135 

1. DTC 

description: 

DTC  P0135 

Front oxygen sensor heater fails 

The pre-catalytic heated oxygen sensor (HO2S) is used for fuel control. The sensor compares the 
oxygen content in ambient air and oxygen content in the exhaust flow. Each heated oxygen sensor 
has an internal heating element for sensor heating. ECM controls the heated oxygen sensor heating 
control circuit. This makes the system enter into the closed-loop control mode earlier, so that ECM 
can calculate Air-fuel ratio earlier. ECM controls the heating control circuit switched on or off, so 
that heated type oxygen sensor working temperature maintains in the specified range. Engine 
control module detects the temperature by Measure the heater current. 

Front oxygen sensor heating coil voltage is provided by the main relay controlled by ECM, when 
the ignition switch is turned to ON, EM04 sensor harness connector terminal D will have battery 
voltage. ECM controls heater working hours through ECM harness connector EM01 terminal 
No.14. 

2.  Conditions For Setting DTC and The Fault Location: 

DTC 
Code 

DTC Detection 
Strategy 

Conditions For Setting The 
DTC (Control Strategy) 

Fault Locations 

P0135 

Hardware Circuit 
Inspection 

1. Engine Running Longer 

than 60 s. 

2.  At idle Running Condition.

3. Pre-Catalytic 

Oxygen 

Sensor Heating 

4. Pre-Catalytic 

Oxygen 

Sensor Heating Control 
Terminal Disconnected. 

5. Duration 

Less 

Than 

20s. 

1. Sensor 

Circuit 

2. Sensor 

3. ECM. 

3. Circuit 

sketch 

Refer to 2.2.7.22 DTC P0131 P0132 P0133 P0134. 

4. Diagnostic 

Steps: 

Note: Before carrying out this diagnosis step, observe the data list on fault diagnosis tester and 
analyze the accuracy of the data, as these will help with quick diagnosis. 

Step 1 

Initial Inspection 

Inspect the existence of following factors that will affect the heated type oxygen sensor working 
status: 

(a)  Exhaust system leakage or blockage. 

(b)  Water enters into the heated oxygen sensor connector. 

(c)  After engine working in high temperature, whether exhaust pipes are too hot or not. 

 

Step 2 

Inspect front oxygen sensor heater resistance. 

 

Next 

195

(a)  Rotated ignition switch to OFF 

position . 

(b)  Disconnect front oxygen sensor 

wiring harness connector. 

(c) 

Measure heater resistance 
between front oxygen sensor 
terminals C and D. 

Standard Resistance 

20 (68ºF) 8.1

-11.1Ω 

(d) Connect front oxygen sensor 

wiring harness connector. 

Is resistance the specified value? 

前氧传感器线束连接器

EM04

A

B

C

D

NL02-0040c

 

Step 3 

Inspect the terminal No. D to ground voltage. 

(a)  Rotated ignition switch to OFF position. 

(b)  Disconnect front oxygen sensor wiring harness connector. 

(c)  Rotated ignition switch to ON position. 

(d)  Measure voltage between front oxygen sensor wiring harness connector EM04 terminal D 

and a reliable ground. 

Standard Voltage: 11-14V 

(e)  Connect front oxygen sensor harness connector EM04. 

Is voltage the specified value? 

 

Step 4 

Inspect the front oxygen sensor terminal heating control signal continuity. 

 

No 

Front oxygen sensor heater power supply 
circuit fault 

Yes 

No 

Replace the front oxygen sensor. Go to 
step 11. 

Yes 

Front oxygen sensor harness 

connectorEM04 

196

(a)  Rotated ignition switch to OFF 

position . 

(b)  Disconnect front oxygen sensor 

harness connector EM04. 

(c) 

Disconnect ECM harness 
connector EM01. 

(d) Test Continuity between front 

oxygen sensor wiring harness 
connector EM04 terminal C and 
ECM harness connector EM01 
terminal No.24. 

ECM线束连接器

EM01

1

2

4

5

3

81

63

44

25

6

62

43

24 23 22 21 20 19 18 17 16 15 14 13 12 11 10

9

8

7

26

42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27

45

46

61 60 59 58 57 56 55 54 53 52 51 50 49 48 47

64

65

66

80 79 78 77 76 75 74 73 72 71 70 69 68 67

NL02-0033c

Standard Resistance: Less than 1 Ω 

(e)  Connect ECM harness connector EM01. 

(f)  Connect the front oxygen sensor wiring harness connector EM04. 

Is resistance the specified value? 

 

Step 5 

Inspect ECM working circuit. 

(a)  Inspect whether ECM power supply circuit is normal. 

(b)  Inspect whether ECM ground circuit is normal. 

 

Step 6 

Replace ECM. Refer to 2.2.8.1 Replacement of Engine Control Module. 

(a) Replace 

ECM. 

(b)  Carry out the crankshaft position sensor learning, refer to 2.2.7.11 “Crankshaft Position 

Sensor (CKP) Learning. 

 

Step 7 

Use fault diagnosis tester to confirm if DTC is stored again . 

(a)  Connect the fault diagnosis tester to the diagnostic interface. 

(b)  Turn ignition switch to ON position. 

(c)  Clear DTC code. 

(d)  Start and run the engine at idle speed to warm up the engine for at least 5 min. 

(e)  test the vehicle on the road for at least 5min. 

Yes 

No 

Repair the faulty part. 

Yes 

No 

ECM control circuit malfunction 

Yes 

ECMharness connectorEM01 

197

(f)  Read control system DTC code again to confirm that the system has no DTC code. 

 

Step 8 

Troubleshooting 

5. Maintenance 

guide 

Refer to 2.4.6.2 “Replacement of Front Oxygen Sensor” to replace the front oxygen sensor 

No 

Refer to 2.2.7.3 Intermittent Fault 
Inspection for intermittent fault. 

Yes 

198

 

 

 

 

 

 

 

 

 

содержание   ..  40  41  42  43  44  45  46  47  48  49  50  ..