the ground point G8 

The resistor between the 
terminals 86 and 85 of the 
blower relay does not accord 
with the standard. 

The blower relay faults. 

Replace blower relay 

B. Confirm fault repair was completed 

Does the blower operate normally? 

 

 

 

 

Inspect the voltage of the A/C control module terminal IP40-7. 

 

(a)  Turn the ignition switch to OFF position. 

(b)  Disconnect blower harness connector IP11. 

(c) Inspect connection situation between blower 

relay terminal 87 and blower  harnesses 
connector IP11 terminal 1. 

Standard resistance: less than 1 Ω 

(d)  Confirm circuit of blower relay terminal87 and 

blow harness connector IP11 terminal is normal. 

Does the blower operate normally? 

1

2 3

6 5 4

鼓风机线束连接器

IP11

NL08-2011b

 

 

 

 

Inspect the voltage of the A/C control module terminal B-18. 

(a) Start 

the 

engine. 

(b)  Pressed volume button on the A/C control panel 

(c)  Use multimeter to measure voltage of A/C control module terminal B-18. 

(d)  Standard voltage of each air volume gear is shown in table. 

Air quantity bar shows 

Blower gear 

Auto-mode blower end voltage (V) 

1 1  4.5 

(Auto 

Min.) 

4.6 - 5.5 

5.6 - 6.7 

6.8 - 7.7 

No 

Yes 

The system is normal. 

No 

Yes 

The system is normal. 

IP11 blower harness connector

 

1715

 

7.8 - 8.9 

9.0 - 10.1 

7 7  10.2-11.2 

(Auto 

Max.) 

Is voltage the standard value? 

 

 

 

 

Repair the circuit of the A/C control module and the blower. 

(a)  Turn the ignition switch to OFF position. 

(b)  Inspect connection situation between A/C control module    harnesses connector terminal B-18, B-19, B-20 

and blower    harnesses connector terminal B-18, B-19, B-20. 

Standard resistance: less than 1 Ω 

(c)  Make sure that circuit between A/C control module    harnesses connector t erminal B-18,B-19,B-20 and 

blower  harnesses connector terminal B-18,B-19,B-20 is normal. 

Does the blower operate normally? 

 

 

 

 

Inspect the A/C control module circuit. 

(a)  Inspect power supply and grounding circuit of A/C control module. 

(b)  Make sure A/C control module power supply and grounding are connected normally. 

Does the blower operate normally? 

 

 

 

Replace A/C control module. 

(a)  Replace A/C control module, refer to 8.2.8.1 A/C control panel replacement. 

Does the blower operate normally? 

 

 

 

 

No 

Yes 

The system is normal. 

Yes 

The system is normal. 

No 

Yes 

The system is normal. 

No 

Yes 

The system is normal. 

No 

1716

 

Repair the blower. 

A. Repair according to the following list of symptoms 

Symptoms Suspected 

fault 

part 

Maintenance 

scheme 

Blower jamming 

The blower wheel has foreign 
matter. 
The blower wheel is damaged. 
The blower motor has foreign 
matter and is blocked. 

Clean up the blower wheel foreign body. 
Clean up the blower motor foreign body. 
Replace blower motor assembly, included 
fan impeller 

The blower motor does not 
work. 

The blower motor is damaged. 

Replace blower motor assembly, included 
fan impeller 

B. Confirm that the blower works normally. 

Confirm the completion of repair. 

 

 

The system is normal. 

 

Next 

1717

 

 

8.2.7.10 Insufficient A/C system refrigeration capacity 

Fault symptom table 

Symptoms 

Suspected fault part 

Maintenance scheme 

The engine 
coolant 
temperature is 
too high. 

1.  The engine at idle speed runs too 

long. 

2.  The engine runs with high load 

for a long time. 

3.  Lack of engine coolant 
4.  Coolant performance do not meet 

requirement 

5.  Thermostat Malfunction 
6.  Poor engine working conditions. 
7.  The cooling fan runs abnormally. 
8.  The cooling fan does not work. 
9.  Poor heat dissipation of water 

tank 

10.  The cooling fan air gathering 

hood is damaged. 

1.  Shorten the running time of the engine at the idle 

speed. 

2.  Shorten the running time of the engine with large 

load. 

3.  Repair the cooling fluid leakage condition; and 

add the cooling fluid to the standard value. 

4.  Replace the refrigerant according with the 

requirement of Geely manufacturer. 

5.  Replace the thermostat. 
6.  Overhaul engine cooling system 
7.  Overhaul engine work condition 
8.  Repair the cooling fan motor and circuit thereof; 

and replace if necessary. 

9.  Clean the cooling water tank. 
10.  Repair the cooling water tank and replace if 

necessary. 

11.  Repair the cooling fan wind gathering cover and 

replace if necessary. 

Condenser 
temperature is 
too high 

1.  Poor condenser radiation 
2.  The water temperature of the 

engine is too high. 

1.  Clean the condenser. 
2.  Repair the condenser and replace if necessary. 
3.  Perform the maintenance procedures according 

to the "engine coolant temperature too high" 
symptom. 

The 
compressor 
runs 
abnormally. 

1.  Compressor belt slipping 
2.  Compressor clutch slipping 
3.  Compressor abnormal sound 
4.  Frequent compressor start 
5.  Compressor Inoperation 

1.  Adjust compressor belt, and replace when 

necessary 

2.  Repair the compressor clutch and replace if 

necessary. 

3.  Inspect the amount of the refrigerant and the 

lubrication oil. Refer to the symptom of 
"abnormal A/C system pressure" in the table. 

4.  Repair the compressor clutch circuit. 
5.  Repair the compressor and replace if necessary. 
6.  Repair the A/C pressure switch, and replace if 

necessary. 

7.  Repair the A/C control module, and replace if 

necessary.  

8.  Overhaul engine control module.if 

necessary.replace it 

Air volume of 
the instrument 
panel air outlet 
is too small. 

1.  Instrument air duct blocked 
2.  Instrument air duct leakage 
3.  Air direction control mechanism 

abnormal 

4.  Air direction control motor 

abnormal 

5.  Blower speed is too low. 

1.  Clean up the air outlet of the instrument panel 

and replace if necessary. 

2.  Repair the air outlet passage of the instrument 

panel  and replace if necessary. 

3.  Overhaul wind control mechanism 
4.  Overhaul wind control motor 
5.  Repair circuit. 

1718

 

 

 

 

 

 

 

 

 