8A-346 ELECTRICAL-BODY AND CHASSIS TEMPERATURE GAUGE AND THERMO UNIT (4JA1T(L), 4JH1-TC, C24SE) 1. No temperature indicates at all Checkpoint Trouble Cause
Countermeasure
NG
Gauge function connector then connect 2. Check indicating point when starter SW. is ON
Continuity between 1
E19
(C24SE : 1
E65 ) and 16
B23 (C24SE : 13
B24 )
NG NG OK OK Thermo unit continuity
E19
(C24SE : 1
E65 ) and the ground
Replace the thermo unit
Thermo unit malfunction
NG Thermo unit resistance between connector 1 E19
(C24SE: 1 E65 ) and the ground when disconnecting
|