Symptom: DECKLID RELEASE OUTPUT SHORT TO GROUND When Monitored and Set Condition: DECKLID RELEASE OUTPUT SHORT TO GROUND When Monitored: Whenever the BCM is awake. Set Condition: When the BCM turns on the Decklid Release Driver circuit and detects a voltage of less than 0.5 volts for over 125 milliseconds, this code will set. POSSIBLE CAUSES DTC PRESENT DECKLID RELEASE SOLENOID DECKLID RELEASE DRIVER WIRE SHORT TO GROUND BODY CONTROL MODULE - DECKLID RELEASE DRIVER SHORTED TEST ACTION APPLICABILITY 1 Turn the ignition on. t, erase DTCs. Cycle the ignition switch from Off to Run. t, read DTCs. Does the DRBIII t display DECKLID RELEASE OUTPUT SHORT TO GROUND? All Yes → Go To 2 No → The condition that caused the code to set is not present at this time. Using the wiring diagram/schematic as a guide, inspect the 2 Disconnect the Decklid Release Solenoid. t, erase DTCs. Cycle the ignition switch from Off to Run. t, read DTCs. Does the DRBIII t display DECKLID RELEASE OUTPUT SHORT TO GROUND? All Yes → Go To 3 No → Replace the Decklid Release Solenoid. Perform BODY VERIFICATION TEST - VER 1. 293 POWER DOOR LOCKS/RKE |