13. DISPLAY/SET/EDIT

 

 

B-64693EN-1/01

 

- 2402 - 

Parameters 

8940 

 

Initial screen title character code 1 

 

 

 

8941 

 

Initial screen title character code 2 

to 

 

to 

8949 

 

Initial screen title character code 10 

 

 

[Input type]  Parameter input 

 

[Data type]  Byte 

[Valid data range]  0,32,45,46,48 to

 

57,65 to

 

90 

This parameter sets the character codes of the character string to be displayed on the 
initial screen immediately after power-on. If the number of characters to be displayed is 
less than 10, the parameters corresponding to the space exceeding the character length are 
set to 0. 
The set character code is as follows. 

A

65 

 

N

78 

 

0

48 

 

B

66 

 

O

79 

 

1

49 

 

C

67   

P

80 

 

2

50 

 

D

68   

Q

81 

 

3

51 

 

E

69 

 

R

82 

 

4

52 

 

F

70 

 

S

83 

 

5

53 

 

G

71   

T

84 

 

6

54 

 

H

72   

U

85 

 

7

55 

 

I

73 

 

V

86 

 

8

56 

 

J

74 

 

W

87 

 

9

57 

 

K

75 

 

X

88 

 

32 

Space

 

L

76 

 

Y

89 

 

-

 

45 

Negative sign

 

M

77   

Z

90 

 

.

 

46 

Period

 

 

 

 

 

 

 

Null character

 

When the codes other than the character that can be used are set, space is displayed. 
When 10 parameters are all 0, this function is not executed. 
 

Use example 

For example, the parameter is set as follows when displaying as "FANUC_NC".    ("_" is space ) 
 

Parameter No. 

Input value 

8940 

70 

8941 

65 

8942 

78 

8943 

85 

8944 

67 

8945 

8946 

78 

8947 

67 

8948 

8949 

 
Character-code 0 is basically considered to be space, and it is treated as a null character when there is 
only character-code 0 since 0. 
The input value “0” of parameter No.8945 is treated as space because there are character-codes other than 
0 since No.8946. 
The input value “0” of parameter No.8948 is treated as a null character because there is only 
character-code 0 since No.8949. 
 

B-64693EN-1/01

 

 

13. DISPLAY/SET/EDIT

 

- 2403 - 

13.1.26 

One-touch menu 

Overview 

By using One-touch menu, you can allocate shortcut key of screen witch you use frequently. 
This function can be used with 10.4”, 15” and 19” display. 
 

Signal 

One-touch menu display signal WMDS <F0528.7> 

  [Classification]  Output signal 
 

[Function]  This signal indicates that one-touch menu is being displayed. 

 

[Output cond.]  The signal is set to “1” when: 

One-touch menu is displayed. 

The signal is set to “0” when: 

One-touch menu is not displayed. 

 

Signal address 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

F0528 

 

WMDS 

 

 

 

 

 

 

 

 

NOTE 

 

This signal is set to “1” only while the one-touch menu is displayed. 

 

If machine operation menu is displayed, this signal always 
becomes “0”. 

 

Following display unit that can display one-touch menu is 
necessary for this signal. 

 

10.4-inch, 15-inch, 19-inch 

 

Parameter 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

3208 

 

 

 

PSC 

OFY 

NOS 

 

 

SKY 

 

 

[Input type]  Setting input 

 

[Data type]  Bit 

 

 

#3  NOS

  The one-touch menu is 

0: 

Displayed. 

1: 

Not displayed. 

 

3321 

 

Screen number assigned to the 1st vertical soft key 

to 

 

to 

3336 

 

Screen number assigned to the 16th vertical soft key 

 

 

[Input type]  Parameter input 

 

[Data type]  Word 

[Valid data range]  1 to 10000 

Assign a screen number to be displayed as a shortcut to a vertical soft key. 
 
The 1st to 8th vertical soft keys are displayed on page 1, and the 9th to 16th vertical soft 
keys are displayed on page 2. 
When specifying page 2, be sure to specify "Display of next page" on each page. 
When not specifying page 2, set 0 for the 9th to 16th soft keys. 

13. DISPLAY/SET/EDIT

 

 

B-64693EN-1/01

 

- 2404 - 

In this case, page 2 is not used, so that "Display of next page" need not be specified on 
page 1. 
 
If all of these parameters are 0 when turning on the power supply, one-touch menu of the 
default table is displayed. 
 

NOTE 

1  When screen numbers are specified in at least one of CNC 

parameters Nos. 3321 to 3336, the setting is valid. In the case, 
nothing is displayed in the vertical soft-key where 0 is specified in 
the parameter. 

2  In order to display the default one-touch menu again, it is needed 

to turn off power after all of these parameters are set to 0. 

 

24300 

 

Time for One-touch menu to be closed (before switching screen) 

 

 

[Input type]  Parameter input 

 

[Data type]  Byte 

 

[Unit of data]  sec 

[Valid data range]  0 to 127 

The One-touch menu is automatically closed when the One-touch menu is not operated 
during the time set by this parameter before switching the screen with the One-touch 
menu.   
 

24301 

 

Time for One-touch menu to be closed (after switching screen) 

 

 

[Input type]  Parameter input 

 

[Data type]  Byte 

 

[Unit of data]  sec 

[Valid data range]  -1 to 127 

The One-touch menu is automatically closed when the One-touch menu is not operated 
during the time set by this parameter after switching the screen with the One-touch menu.   
If -1 is set, the one-touch menu closes at once after switching the screen.   
 
Ex1) 
 

In case that until switching the screen from One-touch menu is open, automatic 
close is invalid. 

 

One-touch menu is closed automatically 5 second later after switching the screen. 

 

No.24300 = 0, No.24301 = 5 

 
Ex2) 
 

In case that when One-touch menu is closed automatically with no operation of 
One-touch menu 10 second from open. 

 

One-touch menu is closed automatically just after switching the screen. 

 

No.24300 = 10, No.24301 = -1 

 

NOTE 

1  If 0 is set to parameter No.24300 and No.24301, One-touch menu 

is not closed automatically. 

2  When the One-touch menu switched to the screen being displayed 

now is pressed, parameter No.24301 is applied though the screen 
doesn't switch. 

 

B-64693EN-1/01

 

 

13. DISPLAY/SET/EDIT

 

- 2405 - 

13.2 

EDIT 

13.2.1 

Memory Protection Keys 

Overview 

Memory protection keys can be provided so as not to inadvertently store, change, or delete programs, 
offset values, parameters, settings, and so forth. 
For a multi-path system, protection keys are common to all paths. 
 

Signal 

Memory protection signals KEY1 to KEY4<G0046.3 to G0046.6> 

  [Classification]  Input signal 
 

[Function]  These signals allow MDI panel operations that change the memory contents.  There are 

the following four signals. The target memory contents depend on the setting of bit 7 
(KEY) of parameter No.3290. 
When the KEY is “0” : 

KEY1  :  Allows the input of tool offset values,  workpiece origin offsets, and 

workpiece coordinate system shift values. 

KEY2  :  Allows the setting of data input, macro variable input, and tool life 

management data input. 

KEY3  :  Allows program registration and editing. 
KEY4  :  Allows PMC data (counter data table). 

When the KEY is “1” : 

KEY1  :  Allows program registration, program editing, PMC data input. 
KEY2 to KEY4  :  Not used. 

 

[Operation]  If a memory protection signal is set to “0”, the corresponding operation is disabled. 

If a memory protection signal is “1”, the corresponding operation is enabled. 

 

Signal address 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

G0046 

 

 

KEY4 

KEY3 

KEY2 

KEY1 

 

 

 

 

NOTE 

 

For a multi-path system, signal addresses are common to all paths. 

 

Parameter 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

3290 

 

KEY 

 

 

 

 

 

 

 

 

 

[Input type]  Parameter input 

 

[Data type]  Bit path 

 

 

#7  KEY

  For memory protection keys: 

0: 

The KEY1, KEY2, KEY3, and KEY4 signals are used. 

1: 

Only the KEY1 signal is used. 

 

13. DISPLAY/SET/EDIT

 

 

B-64693EN-1/01

 

- 2406 - 

 
 

13.2.2 

Memory Protection Signal for CNC Parameter 

Overview 

It is possible to use a signal to enable and disable parameter writing. This function is enabled and disabled 
by setting bit 0 (PKY) of parameter  No. 3299, and the signal KEYP<G0046.0> is used to enable and 
disable parameter input. 
Conventionally, parameter writing was enabled and disabled on the setting screen. 
 

Signal 

Memory protection signal KEYP<G0046.0> 

  [Classification]  Input signal 
 

[Function]  Enables or disables operation on CNC parameters from the MDI panel. 

 

[Operation]  If this signal is set to “0”, input of CNC parameters is disabled. 

If this signal is set to “1”, input of CNC parameters is enabled. 
This signal is valid only when bit 0 (PKY) of parameter No. 3299 is set to 1. 
 

Signal address 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

G0046 

 

 

 

 

 

 

 

 

KEYP 

 

NOTE 

 

For a multi-path system, the signal address is common to all paths. 

 

Parameter 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

3299 

 

 

 

 

 

 

 

 

PKY 

 

 

[Input type]  Setting input 

 

[Data type]  Bit 

 

 

#0  PKY

  "PARAMETER WRITE" is: 

0: 

Set on the setting screen (bit 0 (PWE) of setting parameter No. 8900). 

1: 

Set by the memory protection signal KEYP<G0046.0>. 

 

NOTE 

1  The functions of the signals depend on whether KEY=”0” or 

KEY=”1”. 

 

When KEY = “0”: 

- KEY1: Enables a tool offset value, workpiece zero point offset 

value, and workpiece shift value to be input. 

- KEY2: Enables setting data, macro variables, and tool life 

management value to be input. 

- KEY3: Enables program registration and editing. 
- KEY4: Enables PMC data (counter and data table) to be input. 

 

When KEY = “1”: 

- KEY1: Enables program registration and editing, and enables 

PMC parameter input. 

- KEY2 to KEY4: Not used 

2  When a multi-path system is used, the setting for path 1 is followed. 

B-64693EN-1/01

 

 

13. DISPLAY/SET/EDIT

 

- 2407 - 

Notes 

 

When bit 0 (PKY) of parameter No. 3299 is set to 1, “PARAMETER WRITE” on the setting screen 
cannot be set. 

 

When bit 0 (PKY) of parameter No. 3299 has been set to 1 and bit 0 (PWE) of parameter No. 8900 
has been set to 0 at power-on, setting the signal KEYP<G0046.0> to “1”  in the operation mode 
causes alarm SW0100 and stops operation. 

 

13.2.3 

MDI Key Setting 

Overview 

Because the type of the MDI keys of the CNC  is  determined automatically, no additional setting is 
required for the MDI keys. When the machine tool builder's own MDI keys are connected, valid key input 
is made possible by parameter setting. 
 

Parameter 

3160 

 

Setting of MDI unit type 

 

 

[Input type]  Parameter input 

 

[Data type]  Byte 

[Valid data range]  0 to 4 

Set the type of an MDI unit when the type of an MDI unit is not automatically identified. 

Setting value 

Type 

Depends on the system type and display unit type. 

Standard MDI unit for the lathe system 

Standard MDI unit for the machining center system 

 
When 0 is set in this parameter, the type of a MDI unit is determined as follows: 

Type of path control 

Type of indicator 

Type 

When the type for the lathe 
system is used with path 1 

Type of 12 horizontal soft keys 

Standard MDI unit for the lathe 
system 

When the type for the 
machining center system is 
used with path 1 

Type of 12 horizontal soft keys 

Standard MDI unit for the 
machining center system 

 

13.3 

MULTI PATH DISPLAY AND EDIT 

13.3.1 

Multi Path Display 

Overview 

In a multi path  system,  operations such as program  creation  and  data  input  are  performed  with a 
display/operation  target path selected  by  switching. For path selection, the path select  signals are used. 
For a selected path, MDI key operation is performed. 
By parameter setting, a selection can be made to display only one path on the screen at a time or display 
multiple paths on the screen simultaneously. When multiple paths are displayed simultaneously, the order 
of path display can be specified according to the machine configuration and layout. 
Moreover, a selection can be made by a parameter to display the same screen at path switching or to store 
the last displayed screen of each path and display the last displayed screen of a selected path. 
 

13. DISPLAY/SET/EDIT

 

 

B-64693EN-1/01

 

- 2408 - 

Explanation 

  - 

Multi path simultaneous display 

Information about multiple paths can be displayed on one screen simultaneously. 
Multi path information can be displayed simultaneously on the following screens: 

 

Absolute position screen 

 

Relative position screen 

 

Overall position display 

 

Program screen 

 

Program check screen 

 

Tool path graphic screen 

 
MDI key operation is performed for a screen selected with the path select signals. 
The maximum number of paths that can be displayed simultaneously depends on the size of the display 
unit as indicated in the Table 13.3.1 (a). 
 

Table 13.3.1 (a) 

Size of display unit 

Maximum number of simultaneously displayable paths 

7.2, 8.4, or 10.4” 

3 paths 

15” 

4 paths 

 

Setting of multi path simultaneous display 
  - 

Simultaneous display group 

When paths more than the maximum number of simultaneously displayable paths are involved, the paths 
can be divided into several path groups for display. Those groups are referred to as multi  path 
simultaneous display groups. 

 
Example) 
 

When four paths are handled on a 10.4” display unit, all paths cannot be displayed simultaneously. 
So, the paths are divided into two simultaneous display groups: a group consisting of paths 1, 2, and 
3, and a group consisting of paths 4. 

 

Table 13.3.1 (b) 

Path number 

Simultaneous display group number 

1, 2, 3 

 
Use  parameter No.  13131 to set  a  multi path  simultaneous  group  number.  Parameter No.  13131 is a 
path-type parameter. In this parameter, specify a successive number not less than 1. 
In this example, specify 1 in parameter No. 13131 for paths 1, 2, and 3, and specify 2 in parameter No. 
13131 for paths 4. 
 

  - 

Display order number 

In a multi path simultaneous display group, the order of path display can be specified. 
Path information can be displayed in a desired order by specifying display order numbers. 

 
Example) 
 

When six paths are involved and divided into two groups and group 1 is displayed in the order from 
path 3 to path 2 to path 1 and group 2 is displayed in the order from path 4, specify display order 
numbers in each multi path simultaneous display group. 

 

B-64693EN-1/01

 

 

13. DISPLAY/SET/EDIT

 

- 2409 - 

Table 13.3.1 (c) 

Number of 

CNC paths 

Path 

Display group 

number 

(Parameter No. 

13131) 

Display order 

number 

(Parameter No. 

13132) 

Screen display 

(The numbers in the illustration 

below represent path numbers.) 

4 paths 

Path 1 

 

Path 2 

Path 3 

Path 4 

 

Path 5 
Path 6 

 
Use parameter No. 13132 to set a display order number. Parameter No. 13132 is a path-type parameter. In 
this parameter, specify a successive number not less than 1 for each of the paths belonging to a multi path 
simultaneous display group. 
In this example,  specify  1, 2, and 3 for paths 3, 2, and 1  in  display  group  number  1 respectively, and 
specify 1 for paths 4 in display group number 2 respectively. 
 

  - 

Example of setting simultaneous display groups and display order numbers 

Number of 

CNC paths 

Path 

Display group number 

(Parameter No. 13131) 

Display order number 

(Parameter No. 13132) 

Screen display 

(The numbers in the illustration 

below represent path numbers.) 

1 path (*) 

Path 1 

Group 1 

 

3 paths 

Path 1 

Group 1 

 

Path 2 

Path 3 

Path 1 

Group 1 

 

Path 2 

Group 2 

 

Path 3 

Group 3 

 

Path 1 

 

 

Path 2 

 

 

Path 3 

 

 

4 paths 

Path 1 

Group 1 

 

Path 2 

Path 3 

Group 2 

 

Path 4 

 

NOTE 

 

When the number of CNC paths is 1, multi path simultaneous display is disabled. 
In this case, parameters Nos. 13131 and 13132 need not be set. 

 

Switching of simultaneous display group 

When  multi  path  simultaneous  display  groups are set, the screen  display  can be switched  from the 
currently displayed path group to another by performing a group switching operation. 
Two  methods  described  below can be used to switch  from one group  to another in multi  path 
simultaneous display. 
 

2  1  4 

3  2  1 

Group 1

 

Group 2

 

1  2  3 

 

 

 

 

 

 

 

Content      ..     304      305      306      307     ..