11302 

 

CPG 

 

 

 

 

 

 

 

 

 

[Input type]  Parameter input 

 

[Data type]  Bit 

 

 

#7  CPG

  PROG function screen selection is: 

0: 

Not changed according to the CNC mode. 

1: 

Changed according to the CNC mode. 

 

13.1.13 

Screen Switching at Path Switching 

Overview 

When switching from one path to another has been made, the same screen and soft keys as displayed for 
the previous path can be displayed. 
Since the same screen is displayed even after path switching, the user no longer has to change the screen 
display. 
It is also possible to change the screen display to the screen that was selected most recently for each path. 
 

Parameter 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

3208 

 

 

 

PSC 

 

 

 

 

 

 

 

[Input type]  Parameter input 

 

[Data type]  Bit 

 

 

#5  PSC

  When the path is switched based on the path switch signal: 

0: 

The screen display is switched to the last selected screen of the path. 

1: 

The same screen as for the path before switching is displayed. 

If this parameter is set to 0, the screen selected for each path is stored. 
Therefore, when path switching to a path is made, the screen selected last for that path is 
displayed.   
Even if the path is changed, FANUC PICTURE and manual guide 

i

  screen does not 

change to other screen because these screens are common to each path. 

Therefore, different behavior will exist together in case of PSC=0, like as some screen stay 
in the screen and other screen changed to another screen when the path is changed.   

Use with PSC=1 is recommended, so that the screen should not change by the path 
change on all screens. 

 

B-64693EN-1/01

 

 

13. DISPLAY/SET/EDIT

 

- 2339 - 

13.1.14 

Screen Erasure Function and Automatic Screen Erasure 
Function 

Overview 

Keeping the same characters displayed in the same positions on the screen for a long time will shorten the 
life of the LCD. 
To prevent this, the CNC screen can be erased. The screen erasure function allows the user to perform a 
key operation to erase the screen. The automatic screen erasure function erases the screen automatically 
when there has been no key operation for a parameter-set period of time. 
 

Screen erasure function 

When 0 is set in parameter No. 3123, the CNC screen can be erased by pressing the 

 

  key and any 

function key (such as 

 

  or 

 

) at the same time. The CNC screen can be displayed again by 

pressing any function key. 
 

Automatic screen erasure function 

When there has been no key operation for a time (in minutes) set in parameter No. 3123, the CNC screen 
is erased automatically. The CNC screen is displayed again by pressing a key. 
 

  - 

Screen erasure by the automatic screen erasure function 

If the following conditions are all satisfied for the time (in minutes) set in parameter No. 3123, the CNC 
screen is erased. 
Conditions for automatically erasing the CNC screen 

Parameter No. 3123 

 0 

None of the following key operations is performed. 

 

MDI keys 

 

Soft keys 

 

External key input 

No alarm is issued. 

 

  - 

Redisplay of the screen by the automatic screen erasure function 

If one of the following conditions is satisfied when the CNC screen is off, the CNC screen is displayed 
again: 
Conditions for redisplaying the CNC screen 

One of the following key operations is performed. 

 

MDI keys 

 

Soft keys 

 

External key input 

An alarm is issued. 

 

  - 

Screen erasure by using the 

 

  key + function key 

When a non-zero value is set in parameter No. 3123, the screen is not erased with the 

 

  key and a 

function key. 
 

  - 

Set time 

Only the time set in parameter No. 3123 for path 1 is valid. 
 

  - 

Alarm in another path 

When an alarm is issued in any of the paths, the screen is not erased. 

13. DISPLAY/SET/EDIT

 

 

B-64693EN-1/01

 

- 2340 - 

Signal 

Screen erasure disable signal *CRTOF<G0062.1> 

  [Classification]  Input signal 
 

[Function]  This signal enables or disables the screen erasure function/automatic screen erasure 

function. 

 

[Operation]  0: 

Enables the screen erasure function/automatic screen erasure function. 

1: 

Disables the screen erasure function/automatic screen erasure function. 

 

Automatic screen erasure status in-progress signal ERTVA<Fn006.2> 

  [Classification]  Output signal 
 

  [Function]  This signal indicates that the CNC screen is being erased by the automatic screen erasure 

function. 

 

  [Operation]  This signal is set to “1” when: 

The CNC screen is erased by the automatic screen erasure function. 

This signal is set to “0” when: 

One of the following key operations is performed: 

 

MDI key 

 

Soft key 

 

External key input 

An alarm is issued. 

The operation mode is changed. 

The automatic screen erasure disable signal *CRTOF <G0062.1> is set to “1”. 

 

NOTE 

 

This signal is not output when the screen is erased by pressing the 

key and any function key. 

 

Signal address 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

G0062 

 

 

 

 

 

 

 

*CRTOF 

 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

Fn006 

 

 

 

 

 

 

ERTVA 

 

 

 

Parameter 

3123 

 

Time required before a screen saver is activated 

 

 

[Input type]  Setting input 

 

[Data type]  Byte path 

 

[Unit of data]  min 

 

[Valid data range]  0 to 127 

After a time (in minutes) set in parameter No. 3123 passes without key operation, the NC 
screen is erased automatically. Pressing a key causes the NC screen to reappear. 
 

NOTE 

1  Setting 0 disables automatic screen erasure. 
2  This function cannot be used together with manual screen erasure. 

If 1 or a larger value is set in this parameter, manual screen 
erasure is disabled. 

 

 

B-64693EN-1/01

 

 

13. DISPLAY/SET/EDIT

 

- 2341 - 

13.1.15 

Screen Hard Copy Function 

Overview 

This function converts screen information displayed on the CNC into bit map format data and output it to 
a memory card or USB memory. Once output, bit map format data can be displayed and edited on a 
personal computer. 
 

Explanation 

  - 

Start/cancellation methods 

The screen hard copy function is started by pressing and holding down key 

 

  for five seconds or by 

changing the hard copy execution request signal HCREQ <G0067.7> from “0” to “1”. The function can 

be canceled by pressing key 

 

  or by changing the hard copy cancellation request signal HCABT 

<G0067.6> to “1”. 
While the screen hard copy function is in progress, the hard copy execution status signal HCEXE 
<F0061.3> is “1”, and upon completion, it is set to 0. When a screen hard copy cancellation request is 
received, the hard copy cancellation request reception signal HCAB2 <F0061.2> is set to “1” and remains 
in the 1 state until the hard copy function is started again or a reset is made. 
 

  - 

Acquisition and output of screen data 

When the screen hard copy function is started, the function acquires screen data and, immediately after 
the acquisition, outputs bitmap format data to, for example, a memory card inserted into the LCD unit. 
While screen data is being acquired, the screen remains stationary for a few seconds. Acquired screen 
data can be output from the memory card screen. Also, while screen data is being output, "OUTPUT" 
blinks in the status display. 
 

  - 

Screen data file names 

Bit map format screen data files created by this function are assigned the names below: 
 
In case of bit 4 (HCN) of parameter No. 3301 is 0, file name starts with “HDCPY000.BMP” and 
increments the number to 999 as following. 
"HDCPY000.BMP" (Name of a file to be first output to a memory card etc. after power-on) 
"HDCPY001.BMP" (Name of a file to be second output to a memory card etc. after power-on) 
       : 
       : 
"HDCPY999.BMP" (Name of a file to be 1000 output to a memory card etc. after power-on) 
If the screen hard copy function is executed after a file with "HDCPY999.BMP" is output, the file name 
returns to "HDCPY000.BMP". However, if a file with the same file name as the one to be output when 
the screen hard copy function is executed exists on the memory card, alarm SR1973 is issued. If the 
capacity of the memory card is exceeded, alarm SR1962 is issued.   
In either case, screen data is not output, so that either the existing file needs to be deleted or the memory 
card needs to be replaced with a new one. 
In case of using a USB memory, if the name of a file to be output during execution of screen hard copy 
already exists in the memory, the file is overwritten. If the capacity of the USB memory is exceeded, 
alarm SR1932 is issued. In this case, please delete unnecessary files or use a new USB memory.   
 
In case of parameter HCN is 1, file name id defined by the date and the execute number of screen hard 
copy function on that day as following. 
"YYMMDD00.BMP" (Name of a file to be first output to a memory card etc. on that day) 
"YYMMDD01.BMP" (Name of a file to be second output to a memory card etc. on that day) 
       : 
       : 
"YYMMDD99.BMP" (Name of a file to be 100 output to a memory card etc. on that day) 

13. DISPLAY/SET/EDIT

 

 

B-64693EN-1/01

 

- 2342 - 

(YY(00~99) means the year, MM(01~12) means the month and DD(01~31) means the day) 
  (Example) 

If screen hard copy is executed on 2013/04/17 in the first time, bit map format file is created with the 
name of “13041700.BMP”. 

If the screen hard copy function is executed after a file with “YYMMDD99.BMP” is output, the file name 
returns to "YYMMDD00.BMP". However, if a file with the same file name as the one to be output when 
the screen hard copy function is executed exists on the memory card, system searches number which does 
not exist and output the file with that number. If all number files (00~99) exist on the memory card, alarm 
SR1973 is issued. If the capacity of the memory card is exceeded, alarm SR1962 is issued.   
In either case, screen data is not output, so that either the existing file needs to be deleted or the memory 
card needs to be replaced with a new one. 
In case of using a USB memory, if the name of a file to be output during execution of screen hard copy 
already exists in the memory, system searches the file number which does not exist on the memory and 
output the file with that number, same as memory card. If all number files (00~99) exist in the memory, 
the file is overwritten. If the capacity of the USB memory is exceeded, alarm SR1932 is issued. In this 
case, please delete unnecessary files or use a new USB memory.   
 

Limitation 

  - 

Screens whose hard copies cannot be made 

Hard copies of the BOOT screen, the IPL screen, and the system alarm screen cannot be made.

 

 

  - 

Foreground I/O devices 

During DNC operation, for example, screen data cannot be output while a foreground I/O device is in use. 
 

  - 

Canceling the hard copy function 

If the hard copy function is canceled before a hard copy is completed, an incomplete bit map file of data 
that has been output is created. 

 

  - CNC screen display function 

If CNC screen display function is working, the screen hard copy function is disabled. In this case, bit map 
format data can be made by screen copy function of CNC screen display function. Please refer to the 
operator’s manual of CNC screen display function. 
 

  - Output folder 

The screen data is output to the root folder of the memory card or the USB memory.     
 

Signal 

Hard copy cancellation request signal HCABT <G0067.6> 

  [Classification]  Input signal 
 

[Function]  This signal requests the cancellation of the screen hard copy function. 

 

[Operation]  When the signal is set to “1”, the control unit operates as follows: 

Cancels the screen hard copy function if it is being executed. 

Does nothing if the screen hard copy function is not being executed. Note that 
changing HCREQ <G0067.7> from “0” to “1” when HCABT <G0067.6> is “1” 
does not cause the screen hard copy function to be executed. 

 

NOTE 

 

If changing this signal from “0” to “1”, set it to “0” on the PMC after 
the signal is maintained in the 1 state for at least 64 msec. 

 

B-64693EN-1/01

 

 

13. DISPLAY/SET/EDIT

 

- 2343 - 

Hard copy execution request signal HCREQ <G0067.7> 

  [Classification]  Input signal 
 

[Function]  This signal requests the execution of the screen hard copy function. 

 

[Operation]  When the signal is changed from “0” to “1”, the control unit operates as follows: 

Starts creating a hard copy. 

 

NOTE 

 

If changing this signal from “0” to “1”, set it to “0” on the PMC after 
the signal is maintained in the “1” state for at least 64 msec. If 
making another hard copy execution request, wait until the signal is 
maintained in the “0” state for at least 64 msec. 

 

Hard copy cancellation request reception signal HCAB2 <F0061.2> 

  [Classification]  Output signal 
 

[Function]  This signal notifies that a screen hard copy cancellation request is made. 

 

[Operation]  This signal is set to “1” in the following case: 

HCABT <G0067.6> is set to “1” or key 

 

  is pressed, so that the CNC receives 

this as a screen hard copy cancellation request. 

This signal is set to “0” in the following cases: 

A reset is made. 

The screen hard copy is started again. 

 

Hard copy execution status signal HCEXE <F0061.3> 

  [Classification]  Output signal 
 

[Function]  This signal notifies that the screen hard copy function is being executed. 

 

[Operation]  This signal is set to “1” in the following case: 

The screen hard copy function is started by changing HCREQ <G0067.7> from “0” 

to “1” or by pressing and holding down key 

 

  for five seconds. 

This signal is set to “0” in the following cases: 

The screen hard copy function is completed. 

The screen hard copy function is canceled. 

 

 

  Timing charts for input/output signals are shown below Fig. 13.1.15 (a) shows a timing 

chart of the screen hard copy function when it terminates normally, and Fig. 13.1.15 (b) 
shows a timing chart of the screen hard copy function when it is canceled and restarted. 

 

 

Hard copy execution request signal 
(HCREQ)

 

Hard copy execution status signal 
(HCEXE)

 

Least 64 msec

 

 

Fig. 13.1.15 (a) When the screen hard copy function terminates normally 

 

13. DISPLAY/SET/EDIT

 

 

B-64693EN-1/01

 

- 2344 - 

 

Hard copy execution request signal 
(HCREQ)

 

Hard copy execution status signal 
(HCEXE)

 

Hard copy cancellation request signal 
(HCABT)

 

Hard copy cancellation request 
reception signal (HCAB2)

 

Least 64msec 

Least 64msec 

Least 64msec 

Least 64msec 

 

Fig. 13.1.15 (b) When the screen hard copy function is canceled and restarted 

 

Signal address 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

G0067 

 

HCREQ 

HCABT 

 

 

 

 

 

 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

F0061 

 

 

 

 

 

HCEXE 

HCAB2 

 

 

 

Parameter 

0020 

 

I/O CHANNEL : Input/output device selection, or interface number for a foreground input device 

 

 

[Input type]  Setting input 

 

[Data type]  Byte 

 

[Valid data range]  0 to 35 

Set the interface number for a foreground I/O device. 

 

If enabling the screen hard copy function (by setting bit 7 (HDC) of parameter No. 3301 
to 1), set this parameter to 4 (memory card) or 17 (USB memory). 

 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

3301 

 

HDC 

 

 

HCN 

 

 

 

H16 

 

 

[Input type]  Parameter input 

 

[Data type]  Bit path 

 

 

#0  H16

  Bit map data of screen hard copies uses: 

0: 

256 colors. 

1: 

16 colors. 

 

 

#4  HCN

  Bit map file name of the screen hard copy is: 

0: 

“HDCPYxxx.BMP”   

 

(xxx(000~999) means the number of screen hard copy after power-on). 

1: 

“YYMMDDxx.BMP”   
(YY(00~99) means the year, MM(01~12) means the month, DD(01~31) means the 
day and xx(00~99) means the number of screen hard copy in that day) 

 

 

#7  HDC

  A screen hard copy function is: 

0: 

Disabled. 

1: 

Enabled. 

 

Only the value of this parameter that is set for path 1 is effective. 

B-64693EN-1/01

 

 

13. DISPLAY/SET/EDIT

 

- 2345 - 

13.1.16 

Actual Speed Display Axis Selection Signals 

Overview 

These signals specify whether the speed of each axis is added to the display of actual speed.   
The signals can be used when, for example, the movement speed of the slave axis is not added to the 
display of actual speed during synchronous operation. 
The signals are valid for reading of the actual speed of the control axis in the PMC window function 
(function code 26). 
 

NOTE 

 

The actual speed obtained by reading of the actual speed of the control axis in 
the PMC window function (function code 26) is a value used for screen display 
and cannot be used for control. 

 

Signal 

Actual speed display axis selection signals *ACTF1 to *ACTF8 <Gn580> 

  [Classification]  Input signal 
 

[Function]  These signals specify whether the movement speed of each axis is added to the display of 

actual speed. 

 

[Operation]  The movement speed of the axis for which 1 is set is not added to the display of actual 

speed.   
*ACTFx : x=1 . . . The speed of the first axis is not added.   
         x=2 . . . The speed of the second axis is not added. 
         x=3 . . . The speed of the third axis is not added. 
 

    :                : 

 

Signal address 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

Gn580 

 

*ACTF8 

*ACTF7 

*ACTF6 

*ACTF5 

*ACTF4 

*ACTF3 

*ACTF2 

*ACTF1 

 

NOTE 

 

These signals can be used together with bit 3 (NDF) of parameter 
No. 3115, which specifies whether the movement speed of a 
selected axis is considered during calculation of actual speed.   

 

13.1.17 

Custom Macro Variable Name Expansion 31 Characters 

Overview 

This function expands the names of custom macro common variables #500 to #549 to a maximum of 31 
characters in length.   
 

NOTE 

 

This function is an optional function. 

 

 

 

 

 

 

 

 

Content      ..     296      297      298      299     ..