List of system variables
3.2 Channel-specific system variables
$AC_TOOL_R_CORR_ANGLE
Active override of the rotation of the orientation
DOUBLE
Description:
$AC_TOOL_R_CORR_ANGLE
Active override of the rotation of the tool orientation
This system variable returns the angle in degrees between the two vectors $AC_TOOL_R_CORR and $AC_TOOL_R_ACT. This angle does not
depend on the coordinate system in which the direction vector $AC_TOOL_R_CORR_DIR[] is read. If no override of the orientation is active in
the interpolator, this angle is 0.0
Unit
Init value
Min
Max
deg.
0.0
0.0
180.0
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
runin stp
X
7
X
7
X
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_ISRG0
Reduced rapid traverse active
BOOL
Description:
$P_ISRG0
Returns TRUE (1) when reduced rapid traverse active
Unit
Init value
Min
Max
-
FALSE
FALSE
TRUE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
-
0
-
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
Not classified
$P_ISPROGSTOP
Programmed stop 1 active
BOOL
Description:
$P_ISPROGSTOP
Returns TRUE (1) when programmed stop 1 is active.
Unit
Init value
Min
Max
-
FALSE
FALSE
TRUE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
-
0
-
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
Not classified
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
265
List of system variables
3.2 Channel-specific system variables
$P_ISDRF
Handwheel offset active
BOOL
Description:
$P_ISDRF
Returns TRUE (1) when handwheel offset is active
Unit
Init value
Min
Max
-
FALSE
FALSE
TRUE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
-
0
-
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
Not classified
$P_ISSKIP
Skip block active
BOOL
Description:
$P_ISSKIP
Returns TRUE (1) when skip block active
Unit
Init value
Min
Max
-
FALSE
FALSE
TRUE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
-
0
-
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
Not classified
System variables
266
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.2 Channel-specific system variables
$AC_PROGINF
Program controls active
INT
Description:
$AC_PROGINF
Active program controls
This system variable returns the active program controls as bit information.
Bit 0: Skip level 0 active
Bit 1: Skip level 1 active
Bit 2: Skip level 2 active
Bit 3: Skip level 3 active
Bit 4: Skip level 4 active
Bit 5: Skip level 5 active
Bit 6: Skip level 6 active
Bit 7: Skip level 7 active
Bit 8: Skip level 8 active
Bit 9: Skip level 9 active
Bit 10: Dry run feedrate active
Bit 11: M01 selected
Bit 12: DRF (handwheel offset) active
Bit 13: Single block active
Bit 14: Reduced rapid traverse active
Bit 15: Feedrate stop active
Bit 16: Program test active
Bit 17: Associated M01 selected
Bit 18: Configurable stop is selected
Unit
Init value
Min
Max
-
0
0
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
X
7
-
0
X
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_TOFFCR
Programmed tool corner radius offset
DOUBLE
Description:
$P_TOFFCR
Programmed tool corner radius offset.
The variable returns the tool corner radius offset programmed with TOFFLR.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
-
0
-
Write:
-
-
0
-
0
-
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
267
List of system variables
3.2 Channel-specific system variables
$P_TOFFCR
Programmed tool corner radius offset
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
Not classified
$AC_TOFFCR
Programmed tool corner radius offset
DOUBLE
Description:
$AC_TOFFCR
Programmed tool corner radius offset.
The variable returns the tool corner radius offset programmed with TOFFLR.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
runin stp
X
7
X
7
-
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
Not classified
$P_MAGNA1
Number of defined type 1 adapters
INT
Description:
$P_MAGNA1
Number of defined type 1 adapters in the TO unit of the channel.
>0 Successful write access
0 No type 1 adapter defined
-1 'Adapter' function or TOOLMAN is not active
OPI module = T/TMV
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_MAGNA2
Number of defined type 2 adapters
INT
Description:
$P_MAGNA2
Number of defined type 2 adapters in the TO unit of the channel.
>0 Successful write access
0 No type 2 adapter defined
-1 'Adapter' function or TOOLMAN is not active
OPI module = T/TMV
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
System variables
268
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.2 Channel-specific system variables
$P_MAGNA2
Number of defined type 2 adapters
INT
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$A_TOOLADAPT [32000]
Adapter number of the magazine location of the tool
INT
Description:
$A_TOOLADAPT[t]
Number of the adapter assigned to the magazine location,
where the tool or multitool with T no. t is currently located.
Result value = 0 = No adapter at the magazine location or tool is not loaded.
Result value = -1 = 'Adapter' function or tool management is not active.
Result value = -2 = A tool or multitool with T no. t does not exist.
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
X
7
X
7
X
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$A_TOOLMTADAPT [32000]
Adapter number of the multitool location of the tool
INT
Description:
$A_TOOLMTADAPT[t]
Number of the adapter assigned to the multitool location,
where the tool with T no. t is currently located.
Result value = 0 No adapter at the multitool location or tool is not assigned to a multitool location.
Result value = -1 'Adapter' function or TOOLMAN function is not active.
Result value = -2 = A tool with T no. t does not exist.
Result value = -3 Multitool function not active
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
X
7
X
7
X
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
269
List of system variables
3.2 Channel-specific system variables
$AC_IS_ADD_CHAN
Identifier whether the current channel is a handling
BOOL
channel.
Description:
$AC_IS_ADD_CHAN
Identifier whether the channel is a handling channel
Result value = FALSE: current channel is a machining channel
Result value = TRUE: current channel is a handling channel
Unit
Init value
Min
Max
-
FALSE
FALSE
TRUE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
X
7
X
7
X
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
Not classified
$AC_CAEXT_OVR
Override of the external collision avoidance
DOUBLE
Description:
The variable returns the override set by the external collision avoidance. Only valid with active external collision avoidance.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
-
X
0
X
7
-
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
Not classified
$AC_ACT_POLE_TOL
Current end angle tolerance with pole interpolation
DOUBLE
Description:
$AC_ACT_POLE_TOL defines the end angle tolerance with pole interpolation for the current main run block.
This system variable is (currently) only applicable when an orientation transformation defined by kinematic chains is active. If this condition
is not met, the return value is -1.
Unit
Init value
Min
Max
deg.
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
X
7
X
7
X
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
Not classified
System variables
270
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.2 Channel-specific system variables
$P_SEARCH_S_TYPE [1]
Block search: type of spindle programming
INT
Description:
The last type of spindle programming collected during active block search.
Variable $P_SEARCH_S_TYPE corresponds to $P_S_TYPE.
0 Spindle not programmed
1 Spindle speed, S in rpm
2 Cutting speed, SVC in m/min or ft/min
3 Constant cutting speed S in m/min or ft/min
4 Constant grinding wheel peripheral speed S in m/s bzw. ft/s
Index 1:
n: Spindle number (0 ... max. spindle number)
Unit
Init value
Min
Max
-
0
0
31
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
-
0
-
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
Not classified
$P_TRAINT_SPOS_ANGLE
Spindle position to be selected for interpolation turning
DOUBLE
Description:
The variable $P_TRAINT_SPOS_ANGLE reads the correct spindle position for selecting interpolation turning.
Unit
Init value
Min
Max
deg.
0.0
-360
360
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_TRAINT_ROT_ANGLE
Spindle position to be selected for interpolation turning
DOUBLE
Description:
The variable $P_TRAINT_ROT_ANGLE reads the correct frame rotation for selecting interpolation turning.
Unit
Init value
Min
Max
deg.
0.0
-360
360
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
-
-
0
-
0
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
271
List of system variables
3.3 Frames
3.3
Frames
$P_UIFR [n]
Settable data management frames
FRAME
Description:
Array variable $P_UIFR[n] is used to program settable data management frames. G500, G54 .. G599 can be used to activate the corresponding
data management frame. The data management frames are stored in SRAM and can be read in and out using the data backup feature.
The number of settable frames in configured with $MC_MM_NUM_USER_FRAMES.
0: G500
1: G54
2: G55
3: G56
4: G57
5: G505
6: G506
99: G599
Index 1:
The number of settable frames is configured via $MC_MM_NUM_USER_FRAMES.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_CHBFR [n]
Channel-specific basic frames in the data management
FRAME
system
Description:
Array variable $P_CHBFR[n] is used to program channel-specific basic frames in the data management system. G500, G54 .. G599 can be used
to activate the data management frames. All active basic frames are chained together to produce the overall basic frame $P_ACTBFRAME. The
data management frames are stored in SRAM and can be read in and out using the data backup feature.
Index 1:
The number of channel basic frames is configured via $MC_MM_NUM_BASE_FRAMES.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
272
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.3 Frames
$P_SETFR
Data management frame for preset actual value mem-
FRAME
ory
Description:
Variable $P_SETFR is used to program the system frame in the data management system for preset actual value memory and scratching. This
frame should only be manipulated and activated by the system function. The data management frames are stored in SRAM and can be read
in and out using the data backup feature.
On a Reset, the system frame can be cleared by configuring Bit 0 in $MC_CHSFRAME_RESET_CLEAR_MASK.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_EXTFR
Data management frame for external frame
FRAME
Description:
Variable $P_EXTFR is used to program the system frame in the data management system for the external work offset. This frame is activated
by the PLC. The data management frames are stored in SRAM and can be read in and out using the data backup feature.
On a Reset, the system frame can be cleared by configuring Bit 1 in $MC_CHSFRAME_RESET_CLEAR_MASK.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_PARTFR
Data management frame for TCARR and PAROT
FRAME
Description:
Variable $P_PARTFR is used to program the system frame in the data management system for TCARR and PAROT. This frame should only be
manipulated and activated by the system function. The data management frames are stored in SRAM and can be read in and out using the data
backup feature.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
273
List of system variables
3.3 Frames
$P_TOOLFR
Data management frame for TOROT and TOFRAME
FRAME
Description:
Variable $P_TOOLFR is used to program the system frame in the data management system for TOROT and TOFRAME. This frame should only
be manipulated and activated by the system function. The data management frames are stored in SRAM and can be read in and out using the
data backup feature.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_WPFR
Data management frame for workpiece
FRAME
Description:
Variable $P_WPFR is used to program the system frame in the data management system for workpiece reference points. The data management
frames are stored in SRAM and can be read in and out using the data backup feature.
On a Reset, the system frame can be cleared by configuring Bit 4 in $MC_CHSFRAME_RESET_CLEAR_MASK.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_CYCFR
Data management frame for cycles
FRAME
Description:
Variable $P_CYCFR is used to program the system frame in the data management system for cycles. This frame should only be manipulated and
activated by cycles. The data management frames are stored in SRAM and can be read in and out using the data backup feature.
On a Reset, the system frame can be cleared by configuring Bit 5 in $MC_CHSFRAME_RESET_CLEAR_MASK.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
274
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.3 Frames
$P_TRAFR
Data management frame for transformations
FRAME
Description:
Variable $P_TRAFR is used to program the system frame in the data management system for transformations. This frame should only be
manipulated and activated by the system function. The data management frames are stored in SRAM and can be read in and out using the data
backup feature.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_ISO1FR
Data management frame for ISO G51.1 mirroring
FRAME
Description:
Variable $P_ISO1FR is used to program the system frame in the data management for the ISO G code G51.1 mirroring.This frame should only
be manipulated and activated via the system function. The data management frames are stored in SRAM and can be read in and out using the
data backup feature.
On reset, the system frame can be deleted via the configuration of bit 0 in $MC_CHSFRAME_RESET_CLEAR_MASK.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_ISO2FR
Data management frame for ISO G68 2DROT
FRAME
Description:
Variable $P_ISO2FR is used to program the system frame in the data management for the ISO G68 2DROT.This frame should only be manip-
ulated and activated via the system function. The data management frames are stored in SRAM and can be read in and out using the data
backup feature.
On reset, the system frame can be deleted via the configuration of bit 0 in $MC_CHSFRAME_RESET_CLEAR_MASK.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
275
List of system variables
3.3 Frames
$P_ISO3FR
Data management frame for ISO G68 3DROT
FRAME
Description:
Variable $P_ISO3FR is used to program the system frame in the data management for the ISO G68 3DROT.This frame should only be manip-
ulated and activated via the system function. The data management frames are stored in SRAM and can be read in and out using the data
backup feature.
On reset, the system frame can be deleted via the configuration of bit 0 in $MC_CHSFRAME_RESET_CLEAR_MASK.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_ISO4FR
Data management frame for ISO G51 Scale
FRAME
Description:
Variable $P_ISO4FR is used to program the system frame in the data management for the ISO G code G51 Scale.This frame should only be
manipulated and activated via the system function. The data management frames are stored in SRAM and can be read in and out using the data
backup feature.
On reset, the system frame can be deleted via the configuration of bit 0 in $MC_CHSFRAME_RESET_CLEAR_MASK.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_RELFR
Data management frame for relative coordinate sys-
FRAME
tems
Description:
The variable $P_RELFR is used for programming the system frame in the data management for relative coordinate systems. This frame should
only be activated and manipulated via the system function. The data managment frames are stored in the SRAM, and can be read in and out
via the data backup.
The system frame is configured in the following machine data:
Bit 11 in $MC_MM_SYSTEM_FRAME_MASK
Bit 11 in $MC_MM_SYSTEM_DATAFRAME_MASK
Bit 11 in $MC_CHSFRAME_RESET_MASK
Bit 11 in $MC_CHSFRAME_RESET_CLEAR_MASK
Bit 11 in $MC_CHSFRAME_POWERON_MASK
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
System variables
276
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.3 Frames
$P_RELFR
Data management frame for relative coordinate sys-
FRAME
tems
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_NCBFR [n]
Global basic frames in the data management system
FRAME
Description:
Array variable $P_NCBFR[n] is used to program global basic frames in the data management system. G500, G54 .. G599 can be used to activate
the data management frames. All active basic frames are chained together to produce the overall basic frame $P_ACTBFRAME. The data
management frames are stored in SRAM and can be read in and out using the data backup feature.
Index 1:
The number of NCU basic frames is configured via $MN_MM_NUM_GLOBAL_BASE_FRAMES.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$P_GFR [n]
Data management frames for grinding applications
FRAME
Description:
The field variable $P_GFR[n] is used to program data management frames for grinding applications. The appropriate data management frame
can be activated via GFRAME1 to GFRAME100. The data management frames are stored in SRAM, and can be read in and out via the data
backup .
The number of grinding frames is configured via $MC_MM_NUM_G_FRAMES.
0: GFRAME0 no grinding frame active
1: GFRAME1
100: GFRAME100
Index 1:
The number of grinding frames is configured via $MC_MM_NUM_G_FRAMES.
Unit
Init value
Min
Max
-
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
GEO
CHAN
MACH
SPIN
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
277
List of system variables
3.4 Channel-specific protection zones
3.4
Channel-specific protection zones
$SC_PA_ACTIV_IMMED [n]
Protection zone immediately active
BOOL
Description:
$SC_PA_ACTIV_IMMED[n]
n: Number of the protection area
Protection area immediately active after boot
TRUE: The protection area is activated immediately after
the control has booted and the axes have been referenced
FALSE: The protection area is not immediately active
Note: This variable can only be written as a system variable and is not affected by
the NC commands between NPROTDEF(..) and EXECUTE(n).
Note: This variable is not restored during REORG.
Note: This variable is saved during data backup.
Blocks: _N_NCK_PRO, _N_COMPLETE_PRO and _N_INITIAL_INI
Index 1:
The maximum dimension is defined via the MD $MC_MM_NUM_PROTECT_AREA_CHAN.
Unit
Init value
Min
Max
-
FALSE
FALSE
TRUE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$SC_PA_T_W [n]
Protection zone specific to workpiece/tool
CHAR
Description:
$SC_PA_T_W[n]
n: Number of the protection area
Protection area specific to workpiece/tool
0: Workpiece-specific protection area
3: Tool-specific protection area
Note: This variable is not restored during REORG.
Note: This variable is saved during data backup.
Blocks: _N_CHAx_PRO, _N_COMPLETE_PRO and _N_INITIAL_INI
CHAx: x=channel no.
Index 1:
The maximum dimension is defined via the MD $MC_MM_NUM_PROTECT_AREA_CHAN.
Unit
Init value
Min
Max
-
0
0
3
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
278
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.4 Channel-specific protection zones
$SC_PA_ORI [n]
Orientation of protection zone
INT
Description:
$SC_PA_ORI[n]
n: Number of the protection area
Orientation of protection area
0: Polygon curve in the plane formed by the 1st and 2nd geo axes (G17)
1: Polygon curve in the plane formed by the 3rd and 1st geo axes (G18)
2: Polygon curve in the plane formed by the 2nd and 3rd geo axes (G19)
Note: This variable is not restored during REORG.
Note: This variable is saved during data backup.
Blocks: _N_CHAx_PRO, _N_COMPLETE_PRO and _N_INITIAL_INI
CHAx: x=channel no.
Index 1:
The maximum dimension is defined via the MD $MC_MM_NUM_PROTECT_AREA_CHAN.
Unit
Init value
Min
Max
-
0
0
2
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$SC_PA_LIM_3DIM [n]
Scope of application-limiting protection zone
INT
Description:
$SC_PA_LIM_3DIM[n]
n: Number of the protection area
Identifier for limitation of protection area in the axis
perpendicular to the polygon curve
0: No limitation
1: Limitation in the positive direction
2: Limitation in the negative direction
3: Limitation in both directions
Note: This variable is not restored during REORG.
Note: This variable is saved during data backup.
Blocks: _N_CHAx_PRO, _N_COMPLETE_PRO and _N_INITIAL_INI
CHAx: x=channel no.
Index 1:
The maximum dimension is defined via the MD $MC_MM_NUM_PROTECT_AREA_CHAN.
Unit
Init value
Min
Max
-
0
0
3
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
279
List of system variables
3.4 Channel-specific protection zones
$SC_PA_PLUS_LIM [n]
Limitation of protection zone applicate plus
DOUBLE
Description:
$SC_PA_PLUS_LIM[n]
n: Number of the protection area
Positive limitation of protection areas in the axis
perpendicular to the polygon curve.
Effective only if $SC_PA_LIM_3DIM[n]=1 or = 3.
Note: This variable is not restored during REORG.
Note: This variable is saved during data backup.
Blocks: _N_CHAx_PRO, _N_COMPLETE_PRO and _N_INITIAL_INI
CHAx: x=channel no.
Index 1:
The maximum dimension is defined via the MD $MC_MM_NUM_PROTECT_AREA_CHAN.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$SC_PA_MINUS_LIM [n]
Limitation of protection zone applicate minus
DOUBLE
Description:
$SC_PA_MINUS_LIM[n]
n: Number of the protection area
Negative limitation of protection area in minus direction in the axis
perpendicular to the polygon curve
Effective only if $SC_PA_LIM_3DIM[n]=2 or = 3.
Note: This variable is not restored during REORG.
Note: This variable is saved during data backup.
Blocks: _N_CHAx_PRO, _N_COMPLETE_PRO and _N_INITIAL_INI
CHAx: x=channel no.
Index 1:
The maximum dimension is defined via the MD $MC_MM_NUM_PROTECT_AREA_CHAN.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
280
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.4 Channel-specific protection zones
$SC_PA_CONT_NUM [n]
Number of valid contour elements
INT
Description:
$SC_PA_CONT_NUM[n]
n: Number of the protection area
Number of valid contour elements
Protection areas need at least 2 contour elements for a complete description.
Note: This variable is not restored during REORG.
Note: This variable is saved during data backup.
Blocks: _N_CHAx_PRO, _N_COMPLETE_PRO and _N_INITIAL_INI
CHAx: x=channel no.
Index 1:
The maximum dimension is defined via the MD $MC_MM_NUM_PROTECT_AREA_CHAN.
Unit
Init value
Min
Max
-
0
0
10
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$SC_PA_CONT_TYP [n,m]
Type of the contour element
INT
Description:
$SC_PA_CONT_TYP"[n,m]
n: Number of the protection area
m: Number of the contour element (0 - MAXNUM_CONTOURNO_PROTECTAREA)
Type (G1, G2, G3) of contour element
=0: Contour not defined
=1: Straight
=2: Circle element (clockwise)
=3: Circle element (counterclockwise)
The end point is determined by $SC_PA_CONT_ORD or $SC_PA_CONT_ABS. With contour types G2 and G3, $SC_PA_CENT_ORD or
$SC_PA_CENT_ABS determines the center point of the circle element.
Note: This variable is not restored during REORG.
Note: This variable is saved during data backup.
Blocks: _N_CHAx_PRO, _N_COMPLETE_PRO and _N_INITIAL_INI
CHAx: x=channel no.
Index 1:
The maximum dimension is defined via the MD $MC_MM_NUM_PROTECT_AREA_CHAN.
Index 2:
m: Number of the contour element (0 - MAXNUM_CONTOURNO_PROTECTAREA)
Unit
Init value
Min
Max
-
0
0
3
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
281
List of system variables
3.4 Channel-specific protection zones
$SC_PA_CONT_TYP [n,m]
Type of the contour element
INT
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$SC_PA_CONT_ORD [n,m]
End point of contour element (ordinate)
DOUBLE
Description:
$SC_PA_CONT_ORD[n,m]
n: Number of the protection area
m: Number of the contour element (0 - MAXNUM_CONTOURNO_PROTECTAREA)
End point of contour element (ordinate)
See also description of $SC_PA_CONT_TYP
Note: This variable is not restored during REORG.
Note: This variable is saved during data backup.
Blocks: _N_CHAx_PRO, _N_COMPLETE_PRO and _N_INITIAL_INI
CHAx: x=channel no.
Index 1:
The maximum dimension is defined via the MD $MC_MM_NUM_PROTECT_AREA_CHAN.
Index 2:
m: Number of the contour element (0 - MAXNUM_CONTOURNO_PROTECTAREA)
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$SC_PA_CONT_ABS [n,m]
End point of contour element (abscissa)
DOUBLE
Description:
$SC_PA_CONT_ABS[n,m]
n: Number of the protection area
m: Number of the contour element (0 - MAXNUM_CONTOURNO_PROTECTAREA)
End point of contour element (abscissa)
See also description of $SC_PA_CONT_TYP
Note: This variable is not restored during REORG.
Note: This variable is saved during data backup.
Blocks: _N_CHAx_PRO, _N_COMPLETE_PRO and _N_INITIAL_INI
CHAx: x=channel no.
Index 1:
The maximum dimension is defined via the MD $MC_MM_NUM_PROTECT_AREA_CHAN.
Index 2:
m: Number of the contour element (0 - MAXNUM_CONTOURNO_PROTECTAREA)
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
282
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.4 Channel-specific protection zones
$SC_PA_CONT_ABS [n,m]
End point of contour element (abscissa)
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$SC_PA_CENT_ORD [n,m]
Center point of contour element (ordinate)
DOUBLE
Description:
$SC_PA_CENT_ORD[n,m]
n: Number of the protection area
m: Number of the contour element (0 - MAXNUM_CONTOURNO_PROTECTAREA)
Center point of contour element (ordinate)
Relevant only if $SC_PA_CONT_TYP[n,m] = 2 or = 3.
Note: This variable is not restored during REORG.
Note: This variable is saved during data backup.
Blocks: _N_CHAx_PRO, _N_COMPLETE_PRO and _N_INITIAL_INI
CHAx: x=channel no.
Index 1:
The maximum dimension is defined via the MD $MC_MM_NUM_PROTECT_AREA_CHAN.
Index 2:
m: Number of the contour element (0 - MAXNUM_CONTOURNO_PROTECTAREA)
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$SC_PA_CENT_ABS [n,m]
Center point of contour element (abscissa)
DOUBLE
Description:
$SC_PA_CENT_ABS[n,m]
n: Number of the protection area
m: Number of the contour element (0 - MAXNUM_CONTOURNO_PROTECTAREA)
Center point of contour element (abscissa)
Relevant only if $SC_PA_CONT_TYP[n,m] = 2 or = 3.
Note: This variable is not restored during REORG.
Note: This variable is saved during data backup.
Blocks: _N_CHAx_PRO, _N_COMPLETE_PRO and _N_INITIAL_INI
CHAx: x=channel no.
Index 1:
The maximum dimension is defined via the MD $MC_MM_NUM_PROTECT_AREA_CHAN.
Index 2:
m: Number of the contour element (0 - MAXNUM_CONTOURNO_PROTECTAREA)
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
283
List of system variables
3.5 Tool holder data
$SC_PA_CENT_ABS [n,m]
Center point of contour element (abscissa)
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
3.5
Tool holder data
$TC_CARR1 [n]
X component of offset vector l1
DOUBLE
Description:
$TC_CARR1[n]
x component of offset vector l1
Attention! All system parameters beginning with '$TC_' are parameters belonging to the TOA area.
The special characteristic of this area is that machine data 28085 = MM_LINK_TOA_UNIT can be set to allow
different NCK channels to access these parameters.
If this type of parameter setting has been selected by the NCK, you must be aware that changing these data can have
a negative impact on other channels. Before you change any data settings, make sure that the changes will have
only a local effect on the channel in which they are made.
Index 1:
The max. number of tool carriers can be set via the machine data $MN_MM_NUM_TOOL_CARRIER. Default value
= 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR2 [n]
Y component of offset vector l1
DOUBLE
Description:
$TC_CARR2[n]
Y component of offset vector l1
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
284
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.5 Tool holder data
$TC_CARR3 [n]
Z component of offset vector l1
DOUBLE
Description:
$TC_CARR3[n]
Z component of offset vector l1
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR4 [n]
X component of offset vector l2
DOUBLE
Description:
$TC_CARR4[n]
X component of offset vector l2
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR5 [n]
Y component of offset vector l2
DOUBLE
Description:
$TC_CARR5[n]
Y component of offset vector l2
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
285
List of system variables
3.5 Tool holder data
$TC_CARR6 [n]
Z component of offset vector l2
DOUBLE
Description:
$TC_CARR6[n]
Z component of offset vector l2
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR7 [n]
X component of rotary axis v1
DOUBLE
Description:
$TC_CARR7[n]
X component of rotary axis v1
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR8 [n]
Y component of rotary axis v1
DOUBLE
Description:
$TC_CARR8[n]
Y component of rotary axis v1
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
286
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.5 Tool holder data
$TC_CARR9 [n]
Z component of rotary axis v1
DOUBLE
Description:
$TC_CARR9[n]
Z component of rotary axis v1
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR10 [n]
X component of rotary axis V2
DOUBLE
Description:
$TC_CARR10[n]
X component of rotary axis v2
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR11 [n]
Y component of rotary axis v2
DOUBLE
Description:
$TC_CARR11[n]
Y component of rotary axis v2
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
287
List of system variables
3.5 Tool holder data
$TC_CARR12 [n]
Z component of rotary axis v2
DOUBLE
Description:
$TC_CARR12[n]
Z component of rotary axis v2
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR13 [n]
Angle of rotation alpha1 (in degrees)
DOUBLE
Description:
$TC_CARR13[n]
Angle of rotation alpha1 (in degrees)
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR14 [n]
Angle of rotation alpha2 (in degrees)
DOUBLE
Description:
$TC_CARR14[n]
Angle of rotation alpha2 (in degrees)
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
288
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.5 Tool holder data
$TC_CARR15 [n]
X component of offset vector l3
DOUBLE
Description:
$TC_CARR15[n]
X component of offset vector l3
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR16 [n]
Y component of offset vector l3
DOUBLE
Description:
$TC_CARR16[n]
Y component of offset vector l3
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR17 [n]
Z component of offset vector l3
DOUBLE
Description:
$TC_CARR17[n]
Z component of offset vector l3
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
289
List of system variables
3.5 Tool holder data
$TC_CARR18 [n]
X component of offset vector l4
DOUBLE
Description:
$TC_CARR18[n]
X component of offset vector l4
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR19 [n]
Y component of offset vector l4
DOUBLE
Description:
$TC_CARR19[n]
Y component of offset vector l4
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR20 [n]
Z component of offset vector l4
DOUBLE
Description:
$TC_CARR20[n]
Z component of offset vector l4
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
290
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.5 Tool holder data
$TC_CARR21 [n]
Axis identifier of 1st rotary axis
AXIS
Description:
$TC_CARR21[n]
Axis identifier of 1st rotary axis
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
GEOAXISNUM
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR22 [n]
Axis identifier of 2nd rotary axis
AXIS
Description:
$TC_CARR22[n]
Axis identifier of 2nd rotary axis
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
GEOAXISNUM
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR23 [n]
Kinematic type
CHAR
Description:
$TC_CARR23[n]
Type of kinematics: P: Rotatable workpiece (Part)
M: Rotatable tool and rotatable workpiece (Mixed)
T or any other character apart from P and M: Rotatable tool
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
'T'
0
CHAR_MAX
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
291
List of system variables
3.5 Tool holder data
$TC_CARR24 [n]
Offset of 1st rotary axis in degrees
DOUBLE
Description:
$TC_CARR24[n]
Offset of 1st rotary axis in degrees
Specifies the angle in degrees of the 1st rotary axis at which the axis assumes its initial position.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR25 [n]
Offset of 2nd rotary axis in degrees
DOUBLE
Description:
$TC_CARR25[n]
Offset of 2nd rotary axis in degrees
Specifies the angle in degrees of the 2nd rotary axis at which the axis assumes its initial position.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR26 [n]
Offset of 1st rotary axis with Hirth teeth
DOUBLE
Description:
$TC_CARR26[n]
Specifies the offset of the 1st rotary axis if its position is not continuously variable (Hirth tooth system).
This variable is evaluated only if $TC_CARR28 is set to a value other than zero.
For exact meanings, please refer to the description of $TC_CARR28
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
292
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.5 Tool holder data
$TC_CARR26 [n]
Offset of 1st rotary axis with Hirth teeth
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR27 [n]
Offset of 2nd rotary axis with Hirth teeth
DOUBLE
Description:
$TC_CARR27[n]
Specifies the offset of the 2nd rotary axis if its position is not continuously variable (Hirth tooth system).
This variable is evaluated only if $TC_CARR29 is set to a value other than zero.
For exact meanings, please refer to the description of $TC_CARR29
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR28 [n]
Minimum incremental step of 1st rotary axis
DOUBLE
Description:
$TC_CARR28[n]
Specifies the size of the minimum increment (in degrees) by which the 1st rotary axis can change position (e.g. with Hirth tooth systems).
A programmed or calculated angle is rounded to the nearest value
calculated from phi = s + n * d
when n is an integer.
In this equation
s = $TC_CARR28
d = $TC_CARR26
If $TC_CARR28 equals zero, $TC_CARR26 and $TC_CARR28 are not used.
The settings in machine data
$MC_TOCARR_ROT_ANGLE_INCR[i] and $MC_TOCARR_ROT_ANGLE_OFFSET[i]
are applied instead.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
293
List of system variables
3.5 Tool holder data
$TC_CARR29 [n]
Minimum incremental step of 2nd rotary axis
DOUBLE
Description:
$TC_CARR29[n]
Specifies the size of the minimum increment (in degrees) by which the 2nd rotary axis can change position (e.g. with Hirth tooth systems).
A programmed or calculated angle is rounded to the nearest value
calculated from phi = s + n * d when n
is an integer.
In this equation
s = $TC_CARR29
d = $TC_CARR27
If $TC_CARR29 equals zero, $TC_CARR27 and $TC_CARR29 are not used.
The settings in machine data
$MC_TOCARR_ROT_ANGLE_INCR[i] and $MC_TOCARR_ROT_ANGLE_OFFSET[i]
are applied instead.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR30 [n]
Minimum position of 1st rotary axis
DOUBLE
Description:
$TC_CARR30[n]
Specifies the minimum position of the 1st rotary axis. For full description, see $TC_CARR32
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR31 [n]
Minimum position of 2nd rotary axis
DOUBLE
Description:
$TC_CARR31[n]
Specifies the minimum position of the 2nd rotary axis. For full description, see $TC_CARR33
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
System variables
294
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.5 Tool holder data
$TC_CARR31 [n]
Minimum position of 2nd rotary axis
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR32 [n]
Maximum position of 1st rotary axis
DOUBLE
Description:
$TC_CARR32[n]
Specifies the maximum position of the 1st rotary axis.
When the angle of the 1st rotary axis of an orientable tool carrier aligned according to a frame (TCOFR) is calculated, the only acceptable
solutions are those which lie within the $TC_CARR30 to $TC_CARR32 range.
The same applies when the rotary angle is programmed absolutely (TCOABS).
The limits are not evaluated if both $TC_CARR30 and $TC_CARR32 equal zero.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR33 [n]
Maximum position of 2nd rotary axis
DOUBLE
Description:
$TC_CARR33[n]
Specifies the maximum position of the 2nd rotary axis.
When the angle of the 2nd rotary axis of an orientable tool carrier aligned according to a frame (TCOFR) is calculated, the only acceptable
solutions are those which lie within the $TC_CARR31 to $TC_CARR33 range.
The same applies when the rotary angle is programmed absolutely (TCOABS).
The limits are not evaluated if both $TC_CARR31 and $TC_CARR33 equal zero.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
295
List of system variables
3.5 Tool holder data
$TC_CARR34 [n]
Freely usable string (tool carrier name)
STRING
Description:
$TC_CARR34[n]
Contains a freely definable string. This is provided as a free identifier for the orientable tool carrier.
However, it currently has no significance within the NCK, and is therefore not evaluated.
This identifier should not be used for other purposes as it may be used in a future upgrade to allow the activation of an orientable tool carrier
via a name rather than a number.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Index 3:
Max. string length
Unit
Init value
Min
Max
-
""
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR35 [n]
Freely available string (1st rotary axis name)
STRING
Description:
$TC_CARR35[n]
Contains a freely definable string. This is provided as a free identifier for the first rotary axis.
Within the NCK, however, it has no significance at all and is therefore not evaluated.
It can also be used for any other purpose.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Index 3:
Max. string length
Unit
Init value
Min
Max
-
""
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR36 [n]
Freely available string (2nd rotary axis name)
STRING
Description:
$TC_CARR36[n]
Contains a freely definable string. This is provided as a free identifier for the second rotary axis.
Within the NCK, however, it has no significance at all and is therefore not evaluated.
It can also be used for any other purpose.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Index 3:
Max. string length
Unit
Init value
Min
Max
-
""
System variables
296
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.5 Tool holder data
$TC_CARR36 [n]
Freely available string (2nd rotary axis name)
STRING
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR37 [n]
Freely available numeric identifier (tool carrier number)
INT
Description:
$TC_CARR37[n]
Contains an integer number for identifying the toolholder.
Within the NCK, however, it has no significance at all and is therefore not evaluated.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR38 [n]
Freely available position value (X position)
DOUBLE
Description:
$TC_CARR38[n]
Contains a position (X component of retraction position)
Within the NCK, however, it has no significance at all and is therefore not evaluated.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR39 [n]
Freely available position value (Y position)
DOUBLE
Description:
$TC_CARR39[n]
Contains a position (Y component of retraction position)
Within the NCK, however, it has no significance at all and is therefore not evaluated.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
297
List of system variables
3.5 Tool holder data
$TC_CARR39 [n]
Freely available position value (Y position)
DOUBLE
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR40 [n]
Freely available position value (Z position)
DOUBLE
Description:
$TC_CARR40[n]
Contains a position (Z component of retraction position)
Within the NCK, however, it has no significance at all and is therefore not evaluated.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR41 [n]
Fine offset X of the offset vector l1
DOUBLE
Description:
$TC_CARR41[n]
X component of fine offset of offset vector l1
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR42 [n]
Fine offset Y of the offset vector l1
DOUBLE
Description:
$TC_CARR42[n]
Y component of fine offset of offset vector l1
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
System variables
298
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.5 Tool holder data
$TC_CARR42 [n]
Fine offset Y of the offset vector l1
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR43 [n]
Fine offset Z of the offset vector l1
DOUBLE
Description:
$TC_CARR43[n]
Z component of fine offset of offset vector l1
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR44 [n]
Fine offset X of the offset vector l2
DOUBLE
Description:
$TC_CARR44[n]
X component of fine offset of offset vector l2
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR45 [n]
Fine offset Y of the offset vector l2
DOUBLE
Description:
$TC_CARR45[n]
Y component of fine offset of offset vector l2
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
299
List of system variables
3.5 Tool holder data
$TC_CARR45 [n]
Fine offset Y of the offset vector l2
DOUBLE
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR46 [n]
Fine offset Z of the offset vector l2
DOUBLE
Description:
$TC_CARR46[n]
Z component of fine offset of offset vector l2
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR55 [n]
Fine offset X of the offset vector l3
DOUBLE
Description:
$TC_CARR55[n]
X component of fine offset of offset vector l3
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR56 [n]
Fine offset Y of the offset vector l3
DOUBLE
Description:
$TC_CARR56[n]
Y component of fine offset of offset vector l3
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
300
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.5 Tool holder data
$TC_CARR56 [n]
Fine offset Y of the offset vector l3
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR57 [n]
Fine offset Z of the offset vector l3
DOUBLE
Description:
$TC_CARR57[n]
Z component of fine offset of offset vector l3
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR58 [n]
Fine offset X of the offset vector l4
DOUBLE
Description:
$TC_CARR58[n]
X component of fine offset of offset vector l4
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR59 [n]
Fine offset Y of the offset vector l4
DOUBLE
Description:
$TC_CARR59[n]
Y component of fine offset of offset vector l4
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
301
List of system variables
3.5 Tool holder data
$TC_CARR59 [n]
Fine offset Y of the offset vector l4
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR60 [n]
Fine offset Z of the offset vector l4
DOUBLE
Description:
$TC_CARR60[n]
Z component of fine offset of offset vector l4
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR64 [n]
Fine offset of 1st rotary axis v1
DOUBLE
Description:
$TC_CARR64[n]
Fine offset of offset ($TC_CARR24) of 1st rotary axis in degrees
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR65 [n]
Fine offset of 2nd rotary axis v2
DOUBLE
Description:
$TC_CARR65[n]
Fine offset of offset ($TC_CARR25) of 2nd rotary axis in degrees
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
302
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.5 Tool holder data
$TC_CARR65 [n]
Fine offset of 2nd rotary axis v2
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR_KIN_TOOL_START [n]
Start element of the TOOL chain for parameterization
STRING
from kinematic chains
Description:
$TC_CARR_KIN_TOOL_START[n]
If this system variable is empty, the transfer of data from a machine model defined by kinematic chains to the tool carrier takes into account
the entire chain from the root element to the end of the chain defined by $TC_CARR_KIN_TOOL_END.
If the variable contains a name, the chain taken into account starts with the starting point of the named element.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Index 3:
Max. string length
Unit
Init value
Min
Max
-
""
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR_KIN_TOOL_END [n]
End element of the tool chain for parameterization from
STRING
kinematic chains
Description:
$TC_CARR_KIN_TOOL_START[n]
Contains the name of the last element of the kinematic chain used to parameterize the tool chain of a tool carrier.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Index 3:
Max. string length
Unit
Init value
Min
Max
-
""
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR_KIN_PART_START [n]
Start element of the PART chain for parameterization
STRING
from kinematic chains
Description:
$TC_CARR_KIN_PART_START[n]
If this system variable is empty, the transfer of data from a machine model defined by kinematic chains to the tool carrier takes into account
the entire chain from the root element to the end of the chain defined by $TC_CARR_KIN_PART_END.
If the variable contains a name, the chain taken into account starts with the starting point of the named element.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
303
List of system variables
3.5 Tool holder data
$TC_CARR_KIN_PART_START [n]
Start element of the PART chain for parameterization
STRING
from kinematic chains
Index 3:
Max. string length
Unit
Init value
Min
Max
-
""
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR_KIN_PART_END [n]
End element of the part chain for parameterization
STRING
from kinematic chains
Description:
$TC_CARR_KIN_TOOL_START[n]
Contains the name of the last element of the kinematic chain used to parameterize the part chain of a tool carrier.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Index 3:
Max. string length
Unit
Init value
Min
Max
-
""
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
304
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.5 Tool holder data
$TC_CARR_KIN_CNTRL [n]
Controls the transfer of geometry data from kinematic
INT
chain elements.
Description:
$TC_CARR_KIN_CNTRL[n]
This system data controls the transfer of geometry data from a machine model defined by kinematic chains to parameterize a tool carrier.
Currently, only bits 0-2 are assigned All other bits are reserved.
The individual bits have the following meanings:
Bit 0 :
If this bit is set, the following geometry data - as far as they are required - are read from kinematic chain elements. The content of the
corresponding tool carrier data from ($TC_CARRxx) is then ignored.
Offset vector l1
($TC_CARR1 - $TC_CARR3)
Offset vector l2
($TC_CARR4 - $TC_CARR6)
Rotary axis direction v1 ($TC_CARR7 - $TC_CARR9)
Rotary axis direction v2 ($TC_CARR10 - $TC_CARR12)
Offset vector l3
($TC_CARR15 - $TC_CARR17)
Offset vector l4
($TC_CARR18 - $TC_CARR20)
Rotary axis offsets
($TC_CARR24 - $TC_CARR25)
Bit 1 - 2 (H2 - H4):
If these bits are set (bit 1: part chain; bit 2: tool chain), the contents of the offset vectors I1 (tool chain) and I4 (part chain) are changed so that
the end point of the chain coincides with the machine zero point ("Close chain").
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Unit
Init value
Min
Max
-
0
0
7
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_CARR_CORR_ELEM [n,4,32]
Name of the offset vector l[m] of a tool carrier.
STRING
Description:
Name of the offset vector l[m] of the tool carrier[n]. A maximum of 4 offset vectors (l1 to l4) are defined for a tool carrier. The first index
designates the index of the tool carrier, the second index the index of the offset vector (1...4).
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Index 2:
Field index m refers to the offset vector [m] (with m = 1...4) of the active tool carrier.
Index 3:
Max. string length
Unit
Init value
Min
Max
-
""
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
305
List of system variables
3.6 Tool parameters
$TC_CARR_KIN_ROTAX_NAME
Rotary axis with index m for parameterization from kin-
STRING
[n,2,32]
ematic chains
Description:
$TC_CARR_KIN_ROTAX_NAME[n,m]
Contains the name of the rotary element of the kinematic chain used to parameterize the mth rotary axis of the nth tool carrier.
Index 1:
The max. number of tool carriers can be set via the machine data. Default value = 0; i.e. NCK has no such data.
Index 2:
The field index m refers to rotary axis [m] (with m = 0...1) of the active tool carrier.
Index 3:
Max. string length
Unit
Init value
Min
Max
-
""
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
3.6
Tool parameters
$TC_DP1 [32000,32000]
Tool type
INT
Description:
$TC_DP1[t,d]
Tool type
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP1[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP2 [32000,32000]
Cutting edge position
DOUBLE
Description:
$TC_DP2[t,d]
Tool point direction
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP2[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
System variables
306
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.6 Tool parameters
$TC_DP2 [32000,32000]
Cutting edge position
DOUBLE
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
0.
10.
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP3 [32000,32000]
Geometry - length 1
DOUBLE
Description:
$TC_DP3[t,d]
Geometry - length 1
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP3[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP4 [32000,32000]
Geometry - length 2
DOUBLE
Description:
$TC_DP4[t,d]
Geometry - length 2
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP4[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
307
List of system variables
3.6 Tool parameters
$TC_DP5 [32000,32000]
Geometry - length 3
DOUBLE
Description:
$TC_DP5[t,d]
Geometry - length 3
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP5[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP6 [32000,32000]
Geometry - radius
DOUBLE
Description:
$TC_DP6[t,d]
Geometry - radius
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP6[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP7 [32000,32000]
Slotting saw: corner radius
DOUBLE
Description:
$TC_DP7[t,d]
Slotting saw: Corner radius
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP7[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
308
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.6 Tool parameters
$TC_DP7 [32000,32000]
Slotting saw: corner radius
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP8 [32000,32000]
Slotting saw: length
DOUBLE
Description:
$TC_DP8[t,d]
Slotting saw: Length
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP8[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP9 [32000,32000]
Reserved
DOUBLE
Description:
$TC_DP9[t,d]
Reserved
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP9[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
309
List of system variables
3.6 Tool parameters
$TC_DP10 [32000,32000]
Angle between the end face of the tool and the toroidal
DOUBLE
surface
Description:
$TC_DP10[t,d]
Angle between tool face and toroidal surface
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP10[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP11 [32000,32000]
Angle between long. axis of the tool and the upper end
DOUBLE
of the toroidal surface
Description:
$TC_DP11[t,d]
Angle between tool longitudinal axis and upper end of toroidal surface
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP11[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP12 [32000,32000]
Wear - length 1 - $TC_DP3
DOUBLE
Description:
$TC_DP12[t,d]
Wear - length 1 - $TC_DP3
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP12[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
System variables
310
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.6 Tool parameters
$TC_DP12 [32000,32000]
Wear - length 1 - $TC_DP3
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP13 [32000,32000]
Wear - length 2 - $TC_DP4
DOUBLE
Description:
$TC_DP13[t,d]
Wear - length 2 - $TC_DP4
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP13[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP14 [32000,32000]
Wear - length 3 - $TC_DP5
DOUBLE
Description:
$TC_DP14[t,d]
Wear - length 3 - $TC_DP5
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP14[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
311
List of system variables
3.6 Tool parameters
$TC_DP15 [32000,32000]
Wear - radius - $TC_DP6
DOUBLE
Description:
$TC_DP15[t,d]
Wear - radius - $TC_DP6
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP15[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP16 [32000,32000]
Slotting saw: wear on corner radius - $TC_DP7
DOUBLE
Description:
$TC_DP16[t,d]
Slotting saw: Wear - corner radius - $TC_DP7
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP16[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP17 [32000,32000]
Slotting saw: wear on length - $TC_DP8
DOUBLE
Description:
$TC_DP17[t,d]
Slotting saw: Wear length - $TC_DP8
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP17[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
312
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.6 Tool parameters
$TC_DP17 [32000,32000]
Slotting saw: wear on length - $TC_DP8
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP18 [32000,32000]
Wear - reserved - $TC_DP9
DOUBLE
Description:
$TC_DP18[t,d]
Wear - reserved - $TC_DP9
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP18[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP19 [32000,32000]
Wear - angle between the end face of tool and the tor-
DOUBLE
oidal surface - $TC_DP10
Description:
$TC_DP19[t,d]
Wear - angle between tool face and toroidal surface - $TC_DP10
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP19[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
313
List of system variables
3.6 Tool parameters
$TC_DP20 [32000,32000]
Wear - angle between long. axis of tool and upper end of
DOUBLE
the toroidal surface
Description:
$TC_DP20[t,d]
Wear - angle between tool longitudinal axis and upper end of toroidal surface - $TC_DP11
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP20[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP21 [32000,32000]
Basis - length 1
DOUBLE
Description:
$TC_DP21[t,d]
Basis - length 1
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP21[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP22 [32000,32000]
Basis - length 2
DOUBLE
Description:
$TC_DP22[t,d]
Basis - length 2
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP22[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
System variables
314
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.6 Tool parameters
$TC_DP22 [32000,32000]
Basis - length 2
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP23 [32000,32000]
Basis - length 3
DOUBLE
Description:
$TC_DP23[t,d]
Basis - length 3
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP23[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DP24 [32000,32000]
Clear angle
DOUBLE
Description:
$TC_DP24[t,d]
Clearance angle
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP24[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
315
List of system variables
3.6 Tool parameters
$TC_DP25 [32000,32000]
Reserved
DOUBLE
Description:
$TC_DP25[t,d]
Reserved
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DP25[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPCE [32000,32000]
Cutting edge number
INT
Description:
$TC_DPCE[t,d] = 'cutting edge number' of compensation data block t,d
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPCE[d]
CE stands for <C>utting<E>dge
Value range of legal 'cutting edge numbers':
1 up to value of machine data $MN_MM_MAX_CUTTING_EDGE_PERTOOL.
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPH [32000,32000]
H number of the correction data block with ISO2.1 mode
INT
Description:
$TC_DPH[t,d] = 'H cutting edge number' of compensation data block t,d for Fanuc0 M
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPH[d]
An alarm is issued if this variable is used with the function "ISO2.1 mode" or "ISO3.1 mode" inactive.
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
System variables
316
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.6 Tool parameters
$TC_DPH [32000,32000]
H number of the correction data block with ISO2.1 mode
INT
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPV [32000,32000]
Tool edge orientation
INT
Description:
$TC_DPV[t,d] = tool cutting edge orientation
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPV[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPV3 [32000,32000]
L1 component of the tool edge orientation
DOUBLE
Description:
$TC_DPV3[t,d] = L1 component of tool cutting edge orientation
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPV3[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
317
List of system variables
3.6 Tool parameters
$TC_DPV4 [32000,32000]
L2 component of the tool edge orientation
DOUBLE
Description:
$TC_DPV4[t,d] = L2 component of tool cutting edge orientation
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPV4[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPV5 [32000,32000]
L3 component of the tool edge orientation
DOUBLE
Description:
$TC_DPV5[t,d] = L3 component of tool cutting edge orientation
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPV5[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPVN3 [32000,32000]
L1 component of the orientation normal
DOUBLE
Description:
$TC_DPVN3[t,d] = L1 component of the orientation normal of the tool cutting edge.
If the function 'flat D-number management' is active, the syntax is as follows:
$TC_DPVN3[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
318
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.6 Tool parameters
$TC_DPVN3 [32000,32000]
L1 component of the orientation normal
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPVN4 [32000,32000]
L2 component of the orientation normal
DOUBLE
Description:
$TC_DPVN4[t,d] = L2 component of the orientation normal of the tool cutting edge.
If the function 'flat D-number management' is active, the syntax is as follows:
$TC_DPVN4[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPVN5 [32000,32000]
L3 component of the orientation normal
DOUBLE
Description:
$TC_DPVN5[t,d] = L3 component of the orientation normal of the tool cutting edge.
If the function 'flat D-number management' is active, the syntax is as follows:
$TC_DPVN5[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPNT [32000,32000]
Number of teeth on this cutting edge
INT
Description:
$TC_DPNT[t,d]
Number of teeth in the cutting edge
with active function 'flat D number management' the syntax is as follows:
$TC_DPNT[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
319
List of system variables
3.7 OEM user cutting edge data
$TC_DPNT [32000,32000]
Number of teeth on this cutting edge
INT
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPROT [32000,32000]
Base angle of rotation of cutting edge
DOUBLE
Description:
$TC_DPROT[t,d]
Base angle of rotation of this cutting edge
If the function 'flat D number management' is active, the syntax is as follows:
$TC_DPROT[d]
This angle describes the rotation of the cutting edge along the tool offset length L1 from a zero position of the tool holder, e.g. in the spindle.
The angle can be used for aligning the cutting edge of non-axially symmetrical tools.
Application example: A turning tool is chucked in a spindle. The angle is then the difference between the perpendicular onto the cutting tip and
the neutral position of the spindle. This parameter is relevant only for tools that are not rotationally symmetrical.
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
deg.
0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
3.7
OEM user cutting edge data
$TC_DPC1 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC1[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC1[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
System variables
320
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_DPC1 [32000,32000]
-
DOUBLE
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC2 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC2[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC2[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC3 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC3[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC3[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
321
List of system variables
3.7 OEM user cutting edge data
$TC_DPC4 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC4[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC4[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC5 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC5[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC5[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC6 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC6[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC6[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
322
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_DPC6 [32000,32000]
-
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC7 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC7[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC7[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC8 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC8[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC8[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
323
List of system variables
3.7 OEM user cutting edge data
$TC_DPC9 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC9[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC9[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC10 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC10[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC10[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC11 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC11[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC11[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
324
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_DPC11 [32000,32000]
-
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC12 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC12[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC12[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC13 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC13[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC13[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
325
List of system variables
3.7 OEM user cutting edge data
$TC_DPC14 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC14[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC14[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC15 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC15[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC15[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC16 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC16[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC16[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
326
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_DPC16 [32000,32000]
-
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC17 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC17[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC17[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC18 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC18[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC18[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
327
List of system variables
3.7 OEM user cutting edge data
$TC_DPC19 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC19[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC19[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC20 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC20[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC20[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC21 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC21[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC21[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
328
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_DPC21 [32000,32000]
-
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC22 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC22[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC22[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC23 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC23[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC23[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
329
List of system variables
3.7 OEM user cutting edge data
$TC_DPC24 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC24[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC24[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC25 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC25[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC25[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC26 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC26[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC26[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
330
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_DPC26 [32000,32000]
-
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC27 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC27[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC27[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC28 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC28[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC28[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
331
List of system variables
3.7 OEM user cutting edge data
$TC_DPC29 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC29[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC29[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC30 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC30[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC30[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC31 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC31[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC31[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
332
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_DPC31 [32000,32000]
-
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC32 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC32[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC32[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC33 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC33[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC33[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
333
List of system variables
3.7 OEM user cutting edge data
$TC_DPC34 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC34[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC34[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC35 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC35[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC35[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC36 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC36[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC36[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
334
List Manual, 10/2020, 6FC5397-6AP40-6BA4
|
||
|
|
|