SINUMERIK 840D sl. Service - Configuring Commissioning. Manual (2011-2020) - page 97

 

  Index      Manuals     SINUMERIK 840D sl. Service - Configuring Commissioning. Manual (2011-2020)

 

Search            copyright infringement  

 

   

 

   

 

Content      ..     95      96      97      98     ..

 

 

 

SINUMERIK 840D sl. Service - Configuring Commissioning. Manual (2011-2020) - page 97

 

 

List of system variables
3.7 OEM user cutting edge data
$TC_DPC36 [32000,32000]
-
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC37 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC37[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC37[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC38 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC38[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC38[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
335
List of system variables
3.7 OEM user cutting edge data
$TC_DPC39 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC39[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC39[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC40 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC40[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC40[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC41 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC41[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC41[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
336
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_DPC41 [32000,32000]
-
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC42 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC42[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC42[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC43 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC43[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC43[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
337
List of system variables
3.7 OEM user cutting edge data
$TC_DPC44 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC44[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC44[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC45 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC45[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC45[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC46 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC46[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC46[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
338
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_DPC46 [32000,32000]
-
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC47 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC47[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC47[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC48 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC48[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC48[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
339
List of system variables
3.7 OEM user cutting edge data
$TC_DPC49 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC49[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC49[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC50 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC50[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC50[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC51 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC51[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC51[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
340
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_DPC51 [32000,32000]
-
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC52 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC52[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC52[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC53 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC53[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC53[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
341
List of system variables
3.7 OEM user cutting edge data
$TC_DPC54 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC54[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC54[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC55 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC55[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC55[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC56 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC56[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC56[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
342
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_DPC56 [32000,32000]
-
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC57 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC57[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC57[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC58 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC58[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC58[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
343
List of system variables
3.7 OEM user cutting edge data
$TC_DPC59 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC59[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC59[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC60 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC60[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC60[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC61 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC61[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC61[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
344
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_DPC61 [32000,32000]
-
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC62 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC62[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC62[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPC63 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC63[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC63[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
345
List of system variables
3.7 OEM user cutting edge data
$TC_DPC64 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPC64[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPC64[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPCS1 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPCS1[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPCS1[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPCS2 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPCS2[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPCS2[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
346
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_DPCS2 [32000,32000]
-
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPCS3 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPCS3[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPCS3[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPCS4 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPCS4[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPCS4[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
347
List of system variables
3.7 OEM user cutting edge data
$TC_DPCS5 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPCS5[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPCS5[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPCS6 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPCS6[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPCS6[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPCS7 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPCS7[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPCS7[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
System variables
348
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_DPCS7 [32000,32000]
-
DOUBLE
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPCS8 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPCS8[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPCS8[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_DPCS9 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPCS9[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPCS9[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
349
List of system variables
3.7 OEM user cutting edge data
$TC_DPCS10 [32000,32000]
-
DOUBLE
Description:
The type can be specified by machine data. DOUBLE is the default setting
$TC_DPCS10[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_DPCS10[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP13 [32000,32000]
Location-dependent wear correction to $TC_DP3
DOUBLE
Description:
Offset for $TC_DP3: $TC_SCP13[t,d] comparable to $TC_DP12[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP13[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP14 [32000,32000]
Location-dependent wear correction to $TC_DP4
DOUBLE
Description:
Offset for $TC_DP4: $TC_SCP14[t,d] comparable to $TC_DP13[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP14[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
System variables
350
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_SCP14 [32000,32000]
Location-dependent wear correction to $TC_DP4
DOUBLE
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP15 [32000,32000]
Location-dependent wear correction to $TC_DP5
DOUBLE
Description:
Offset for $TC_DP5: $TC_SCP15[t,d] comparable to $TC_DP14[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP15[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP16 [32000,32000]
Location-dependent wear correction to $TC_DP6
DOUBLE
Description:
Offset for $TC_DP6: $TC_SCP16[t,d] comparable to $TC_DP15[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP16[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP17 [32000,32000]
Location-dependent wear correction to $TC_DP7
DOUBLE
Description:
Offset for $TC_DP7: $TC_SCP17[t,d] comparable to $TC_DP16[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP17[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
351
List of system variables
3.7 OEM user cutting edge data
$TC_SCP17 [32000,32000]
Location-dependent wear correction to $TC_DP7
DOUBLE
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP18 [32000,32000]
Location-dependent wear correction to $TC_DP8
DOUBLE
Description:
Offset for $TC_DP8: $TC_SCP18[t,d] comparable to $TC_DP17[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP18[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP19 [32000,32000]
Location-dependent wear correction to $TC_DP9
DOUBLE
Description:
Offset for $TC_DP9: $TC_SCP19[t,d] comparable to $TC_DP18[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP19[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
352
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_SCP20 [32000,32000]
Location-dependent wear correction to $TC_DP10
DOUBLE
Description:
Offset for $TC_DP10: $TC_SCP20[t,d] comparable to $TC_DP19[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP20[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP21 [32000,32000]
Location-dependent wear correction to $TC_DP11
DOUBLE
Description:
Offset for $TC_DP11: $TC_SCP21[t,d] comparable to $TC_DP20[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP21[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP23 [32000,32000]
Location-dependent wear correction to $TC_DP3
DOUBLE
Description:
Offset for $TC_DP3: $TC_SCP23[t,d] comparable to $TC_DP12[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP23[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
353
List of system variables
3.7 OEM user cutting edge data
$TC_SCP23 [32000,32000]
Location-dependent wear correction to $TC_DP3
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP24 [32000,32000]
Location-dependent wear correction to $TC_DP4
DOUBLE
Description:
Offset for $TC_DP4: $TC_SCP24[t,d] comparable to $TC_DP13[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP24[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP25 [32000,32000]
Location-dependent wear correction to $TC_DP5
DOUBLE
Description:
Offset for $TC_DP5: $TC_SCP25[t,d] comparable to $TC_DP14[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP25[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP26 [32000,32000]
Location-dependent wear correction to $TC_DP6
DOUBLE
Description:
Offset for $TC_DP6: $TC_SCP26[t,d] comparable to $TC_DP15[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP26[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
System variables
354
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_SCP26 [32000,32000]
Location-dependent wear correction to $TC_DP6
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP27 [32000,32000]
Location-dependent wear correction to $TC_DP7
DOUBLE
Description:
Offset for $TC_DP7: $TC_SCP27[t,d] comparable to $TC_DP16[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP27[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP28 [32000,32000]
Location-dependent wear correction to $TC_DP8
DOUBLE
Description:
Offset for $TC_DP8: $TC_SCP28[t,d] comparable to $TC_DP17[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP28[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
355
List of system variables
3.7 OEM user cutting edge data
$TC_SCP29 [32000,32000]
Location-dependent wear correction to $TC_DP9
DOUBLE
Description:
Offset for $TC_DP9: $TC_SCP29[t,d] comparable to $TC_DP18[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP29[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP30 [32000,32000]
Location-dependent wear correction to $TC_DP10
DOUBLE
Description:
Offset for $TC_DP10: $TC_SCP30[t,d] comparable to $TC_DP19[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP30[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP31 [32000,32000]
Location-dependent wear correction to $TC_DP11
DOUBLE
Description:
Offset for $TC_DP11: $TC_SCP31[t,d] comparable to $TC_DP20[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP31[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
356
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_SCP31 [32000,32000]
Location-dependent wear correction to $TC_DP11
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP33 [32000,32000]
Location-dependent wear correction to $TC_DP3
DOUBLE
Description:
Offset for $TC_DP3: $TC_SCP33[t,d] comparable to $TC_DP12[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP33[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP34 [32000,32000]
Location-dependent wear correction to $TC_DP4
DOUBLE
Description:
Offset for $TC_DP4: $TC_SCP34[t,d] comparable to $TC_DP13[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP34[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP35 [32000,32000]
Location-dependent wear correction to $TC_DP5
DOUBLE
Description:
Offset for $TC_DP5: $TC_SCP35[t,d] comparable to $TC_DP14[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP35[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
357
List of system variables
3.7 OEM user cutting edge data
$TC_SCP35 [32000,32000]
Location-dependent wear correction to $TC_DP5
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP36 [32000,32000]
Location-dependent wear correction to $TC_DP6
DOUBLE
Description:
Offset for $TC_DP6: $TC_SCP36[t,d] comparable to $TC_DP15[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP36[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP37 [32000,32000]
Location-dependent wear correction to $TC_DP7
DOUBLE
Description:
Offset for $TC_DP7: $TC_SCP37[t,d] comparable to $TC_DP16[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP37[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
358
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_SCP38 [32000,32000]
Location-dependent wear correction to $TC_DP8
DOUBLE
Description:
Offset for $TC_DP8: $TC_SCP38[t,d] comparable to $TC_DP17[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP38[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP39 [32000,32000]
Location-dependent wear correction to $TC_DP9
DOUBLE
Description:
Offset for $TC_DP9: $TC_SCP39[t,d] comparable to $TC_DP18[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP39[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP40 [32000,32000]
Location-dependent wear correction to $TC_DP10
DOUBLE
Description:
Offset for $TC_DP10: $TC_SCP40[t,d] comparable to $TC_DP19[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP40[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
359
List of system variables
3.7 OEM user cutting edge data
$TC_SCP40 [32000,32000]
Location-dependent wear correction to $TC_DP10
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP41 [32000,32000]
Location-dependent wear correction to $TC_DP11
DOUBLE
Description:
Offset for $TC_DP11: $TC_SCP41[t,d] comparable to $TC_DP20[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP41[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP43 [32000,32000]
Location-dependent wear correction to $TC_DP3
DOUBLE
Description:
Offset for $TC_DP3: $TC_SCP43[t,d] comparable to $TC_DP12[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP43[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP44 [32000,32000]
Location-dependent wear correction to $TC_DP4
DOUBLE
Description:
Offset for $TC_DP4: $TC_SCP44[t,d] comparable to $TC_DP13[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP44[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
System variables
360
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_SCP44 [32000,32000]
Location-dependent wear correction to $TC_DP4
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP45 [32000,32000]
Location-dependent wear correction to $TC_DP5
DOUBLE
Description:
Offset for $TC_DP5: $TC_SCP45[t,d] comparable to $TC_DP14[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP45[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP46 [32000,32000]
Location-dependent wear correction to $TC_DP6
DOUBLE
Description:
Offset for $TC_DP6: $TC_SCP46[t,d] comparable to $TC_DP15[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP46[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
361
List of system variables
3.7 OEM user cutting edge data
$TC_SCP47 [32000,32000]
Location-dependent wear correction to $TC_DP7
DOUBLE
Description:
Offset for $TC_DP7: $TC_SCP47[t,d] comparable to $TC_DP16[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP47[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP48 [32000,32000]
Location-dependent wear correction to $TC_DP8
DOUBLE
Description:
Offset for $TC_DP8: $TC_SCP48[t,d] comparable to $TC_DP17[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP48[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP49 [32000,32000]
Location-dependent wear correction to $TC_DP9
DOUBLE
Description:
Offset for $TC_DP9: $TC_SCP49[t,d] comparable to $TC_DP18[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP49[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
362
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_SCP49 [32000,32000]
Location-dependent wear correction to $TC_DP9
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP50 [32000,32000]
Location-dependent wear correction to $TC_DP10
DOUBLE
Description:
Offset for $TC_DP10: $TC_SCP50[t,d] comparable to $TC_DP19[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP50[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP51 [32000,32000]
Location-dependent wear correction to $TC_DP11
DOUBLE
Description:
Offset for $TC_DP11: $TC_SCP51[t,d] comparable to $TC_DP20[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP51[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP53 [32000,32000]
Location-dependent wear correction to $TC_DP3
DOUBLE
Description:
Offset for $TC_DP3: $TC_SCP53[t,d] comparable to $TC_DP12[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP53[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
363
List of system variables
3.7 OEM user cutting edge data
$TC_SCP53 [32000,32000]
Location-dependent wear correction to $TC_DP3
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP54 [32000,32000]
Location-dependent wear correction to $TC_DP4
DOUBLE
Description:
Offset for $TC_DP4: $TC_SCP54[t,d] comparable to $TC_DP13[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP54[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP55 [32000,32000]
Location-dependent wear correction to $TC_DP5
DOUBLE
Description:
Offset for $TC_DP5: $TC_SCP55[t,d] comparable to $TC_DP14[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP55[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
364
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_SCP56 [32000,32000]
Location-dependent wear correction to $TC_DP6
DOUBLE
Description:
Offset for $TC_DP6: $TC_SCP56[t,d] comparable to $TC_DP15[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP56[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP57 [32000,32000]
Location-dependent wear correction to $TC_DP7
DOUBLE
Description:
Offset for $TC_DP7: $TC_SCP57[t,d] comparable to $TC_DP16[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP57[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP58 [32000,32000]
Location-dependent wear correction to $TC_DP8
DOUBLE
Description:
Offset for $TC_DP8: $TC_SCP58[t,d] comparable to $TC_DP17[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP58[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
365
List of system variables
3.7 OEM user cutting edge data
$TC_SCP58 [32000,32000]
Location-dependent wear correction to $TC_DP8
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP59 [32000,32000]
Location-dependent wear correction to $TC_DP9
DOUBLE
Description:
Offset for $TC_DP9: $TC_SCP59[t,d] comparable to $TC_DP18[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP59[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP60 [32000,32000]
Location-dependent wear correction to $TC_DP10
DOUBLE
Description:
Offset for $TC_DP10: $TC_SCP60[t,d] comparable to $TC_DP19[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP60[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP61 [32000,32000]
Location-dependent wear correction to $TC_DP11
DOUBLE
Description:
Offset for $TC_DP11: $TC_SCP61[t,d] comparable to $TC_DP20[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP61[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
System variables
366
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_SCP61 [32000,32000]
Location-dependent wear correction to $TC_DP11
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP63 [32000,32000]
Location-dependent wear correction to $TC_DP3
DOUBLE
Description:
Offset for $TC_DP3: $TC_SCP63[t,d] comparable to $TC_DP12[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP63[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP64 [32000,32000]
Location-dependent wear correction to $TC_DP4
DOUBLE
Description:
Offset for $TC_DP4: $TC_SCP64[t,d] comparable to $TC_DP13[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP64[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
367
List of system variables
3.7 OEM user cutting edge data
$TC_SCP65 [32000,32000]
Location-dependent wear correction to $TC_DP5
DOUBLE
Description:
Offset for $TC_DP5: $TC_SCP65[t,d] comparable to $TC_DP14[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP65[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP66 [32000,32000]
Location-dependent wear correction to $TC_DP6
DOUBLE
Description:
Offset for $TC_DP6: $TC_SCP66[t,d] comparable to $TC_DP15[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP66[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP67 [32000,32000]
Location-dependent wear correction to $TC_DP7
DOUBLE
Description:
Offset for $TC_DP7: $TC_SCP67[t,d] comparable to $TC_DP16[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP67[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
368
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_SCP67 [32000,32000]
Location-dependent wear correction to $TC_DP7
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP68 [32000,32000]
Location-dependent wear correction to $TC_DP8
DOUBLE
Description:
Offset for $TC_DP8: $TC_SCP68[t,d] comparable to $TC_DP17[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP68[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP69 [32000,32000]
Location-dependent wear correction to $TC_DP9
DOUBLE
Description:
Offset for $TC_DP9: $TC_SCP69[t,d] comparable to $TC_DP18[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP69[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP70 [32000,32000]
Location-dependent wear correction to $TC_DP10
DOUBLE
Description:
Offset for $TC_DP10: $TC_SCP70[t,d] comparable to $TC_DP19[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP70[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
369
List of system variables
3.7 OEM user cutting edge data
$TC_SCP70 [32000,32000]
Location-dependent wear correction to $TC_DP10
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_SCP71 [32000,32000]
Location-dependent wear correction to $TC_DP11
DOUBLE
Description:
Offset for $TC_DP11: $TC_SCP71[t,d] comparable to $TC_DP20[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_SCP71[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP13 [32000,32000]
Location-dependent setting correction to $TC_DP3
DOUBLE
Description:
Offset for $TC_DP3: $TC_ECP13[t,d] comparable to $TC_DP12[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP13[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
370
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_ECP14 [32000,32000]
Location-dependent setting correction to $TC_DP4
DOUBLE
Description:
Offset for $TC_DP4: $TC_ECP14[t,d] comparable to $TC_DP13[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP14[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP15 [32000,32000]
Location-dependent setting correction to $TC_DP5
DOUBLE
Description:
Offset for $TC_DP5: $TC_ECP15[t,d] comparable to $TC_DP14[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP15[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP16 [32000,32000]
Location-dependent setting correction to $TC_DP6
DOUBLE
Description:
Offset for $TC_DP6: $TC_ECP16[t,d] comparable to $TC_DP15[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP16[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
371
List of system variables
3.7 OEM user cutting edge data
$TC_ECP16 [32000,32000]
Location-dependent setting correction to $TC_DP6
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP17 [32000,32000]
Location-dependent setting correction to $TC_DP7
DOUBLE
Description:
Offset for $TC_DP7: $TC_ECP17[t,d] comparable to $TC_DP16[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP17[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP18 [32000,32000]
Location-dependent setting correction to $TC_DP8
DOUBLE
Description:
Offset for $TC_DP8: $TC_ECP18[t,d] comparable to $TC_DP17[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP18[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP19 [32000,32000]
Location-dependent setting correction to $TC_DP9
DOUBLE
Description:
Offset for $TC_DP9: $TC_ECP19[t,d] comparable to $TC_DP18[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP19[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
System variables
372
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_ECP19 [32000,32000]
Location-dependent setting correction to $TC_DP9
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP20 [32000,32000]
Location-dependent setting correction to $TC_DP10
DOUBLE
Description:
Offset for $TC_DP10: $TC_ECP20[t,d] comparable to $TC_DP19[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP20[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP21 [32000,32000]
Location-dependent setting correction to $TC_DP11
DOUBLE
Description:
Offset for $TC_DP11: $TC_ECP21[t,d] comparable to $TC_DP20[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP21[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
373
List of system variables
3.7 OEM user cutting edge data
$TC_ECP23 [32000,32000]
Location-dependent setting correction to $TC_DP3
DOUBLE
Description:
Offset for $TC_DP3: $TC_ECP23[t,d] comparable to $TC_DP12[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP23[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP24 [32000,32000]
Location-dependent setting correction to $TC_DP4
DOUBLE
Description:
Offset for $TC_DP4: $TC_ECP24[t,d] comparable to $TC_DP13[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP24[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP25 [32000,32000]
Location-dependent setting correction to $TC_DP5
DOUBLE
Description:
Offset for $TC_DP5: $TC_ECP25[t,d] comparable to $TC_DP14[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP25[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
374
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_ECP25 [32000,32000]
Location-dependent setting correction to $TC_DP5
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP26 [32000,32000]
Location-dependent setting correction to $TC_DP6
DOUBLE
Description:
Offset for $TC_DP6: $TC_ECP26[t,d] comparable to $TC_DP15[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP26[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP27 [32000,32000]
Location-dependent setting correction to $TC_DP7
DOUBLE
Description:
Offset for $TC_DP7: $TC_ECP27[t,d] comparable to $TC_DP16[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP27[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP28 [32000,32000]
Location-dependent setting correction to $TC_DP8
DOUBLE
Description:
Offset for $TC_DP8: $TC_ECP28[t,d] comparable to $TC_DP17[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP28[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
375
List of system variables
3.7 OEM user cutting edge data
$TC_ECP28 [32000,32000]
Location-dependent setting correction to $TC_DP8
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP29 [32000,32000]
Location-dependent setting correction to $TC_DP9
DOUBLE
Description:
Offset for $TC_DP9: $TC_ECP29[t,d] comparable to $TC_DP18[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP29[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP30 [32000,32000]
Location-dependent setting correction to $TC_DP10
DOUBLE
Description:
Offset for $TC_DP10: $TC_ECP30[t,d] comparable to $TC_DP19[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP30[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
376
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_ECP31 [32000,32000]
Location-dependent setting correction to $TC_DP11
DOUBLE
Description:
Offset for $TC_DP11: $TC_ECP31[t,d] comparable to $TC_DP20[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP31[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP33 [32000,32000]
Location-dependent setting correction to $TC_DP3
DOUBLE
Description:
Offset for $TC_DP3: $TC_ECP33[t,d] comparable to $TC_DP12[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP33[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP34 [32000,32000]
Location-dependent setting correction to $TC_DP4
DOUBLE
Description:
Offset for $TC_DP4: $TC_ECP34[t,d] comparable to $TC_DP13[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP34[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
377
List of system variables
3.7 OEM user cutting edge data
$TC_ECP34 [32000,32000]
Location-dependent setting correction to $TC_DP4
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP35 [32000,32000]
Location-dependent setting correction to $TC_DP5
DOUBLE
Description:
Offset for $TC_DP5: $TC_ECP35[t,d] comparable to $TC_DP14[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP35[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP36 [32000,32000]
Location-dependent setting correction to $TC_DP6
DOUBLE
Description:
Offset for $TC_DP6: $TC_ECP36[t,d] comparable to $TC_DP15[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP36[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP37 [32000,32000]
Location-dependent setting correction to $TC_DP7
DOUBLE
Description:
Offset for $TC_DP7: $TC_ECP37[t,d] comparable to $TC_DP16[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP37[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
System variables
378
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_ECP37 [32000,32000]
Location-dependent setting correction to $TC_DP7
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP38 [32000,32000]
Location-dependent setting correction to $TC_DP8
DOUBLE
Description:
Offset for $TC_DP8: $TC_ECP38[t,d] comparable to $TC_DP17[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP38[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP39 [32000,32000]
Location-dependent setting correction to $TC_DP9
DOUBLE
Description:
Offset for $TC_DP9: $TC_ECP39[t,d] comparable to $TC_DP18[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP39[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
379
List of system variables
3.7 OEM user cutting edge data
$TC_ECP40 [32000,32000]
Location-dependent setting correction to $TC_DP10
DOUBLE
Description:
Offset for $TC_DP10: $TC_ECP40[t,d] comparable to $TC_DP19[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP40[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP41 [32000,32000]
Location-dependent setting correction to $TC_DP11
DOUBLE
Description:
Offset for $TC_DP11: $TC_ECP41[t,d] comparable to $TC_DP20[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP41[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP43 [32000,32000]
Location-dependent setting correction to $TC_DP3
DOUBLE
Description:
Offset for $TC_DP3: $TC_ECP43[t,d] comparable to $TC_DP12[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP43[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
380
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_ECP43 [32000,32000]
Location-dependent setting correction to $TC_DP3
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP44 [32000,32000]
Location-dependent setting correction to $TC_DP4
DOUBLE
Description:
Offset for $TC_DP4: $TC_ECP44[t,d] comparable to $TC_DP13[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP44[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP45 [32000,32000]
Location-dependent setting correction to $TC_DP5
DOUBLE
Description:
Offset for $TC_DP5: $TC_ECP45[t,d] comparable to $TC_DP14[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP45[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP46 [32000,32000]
Location-dependent setting correction to $TC_DP6
DOUBLE
Description:
Offset for $TC_DP6: $TC_ECP46[t,d] comparable to $TC_DP15[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP46[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
381
List of system variables
3.7 OEM user cutting edge data
$TC_ECP46 [32000,32000]
Location-dependent setting correction to $TC_DP6
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP47 [32000,32000]
Location-dependent setting correction to $TC_DP7
DOUBLE
Description:
Offset for $TC_DP7: $TC_ECP47[t,d] comparable to $TC_DP16[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP47[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP48 [32000,32000]
Location-dependent setting correction to $TC_DP8
DOUBLE
Description:
Offset for $TC_DP8: $TC_ECP48[t,d] comparable to $TC_DP17[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP48[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
382
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_ECP49 [32000,32000]
Location-dependent setting correction to $TC_DP9
DOUBLE
Description:
Offset for $TC_DP9: $TC_ECP49[t,d] comparable to $TC_DP18[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP49[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP50 [32000,32000]
Location-dependent setting correction to $TC_DP10
DOUBLE
Description:
Offset for $TC_DP10: $TC_ECP50[t,d] comparable to $TC_DP19[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP50[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP51 [32000,32000]
Location-dependent setting correction to $TC_DP11
DOUBLE
Description:
Offset for $TC_DP11: $TC_ECP51[t,d] comparable to $TC_DP20[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP51[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
383
List of system variables
3.7 OEM user cutting edge data
$TC_ECP51 [32000,32000]
Location-dependent setting correction to $TC_DP11
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP53 [32000,32000]
Location-dependent setting correction to $TC_DP3
DOUBLE
Description:
Offset for $TC_DP3: $TC_ECP53[t,d] comparable to $TC_DP12[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP53[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP54 [32000,32000]
Location-dependent setting correction to $TC_DP4
DOUBLE
Description:
Offset for $TC_DP4: $TC_ECP54[t,d] comparable to $TC_DP13[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP54[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP55 [32000,32000]
Location-dependent setting correction to $TC_DP5
DOUBLE
Description:
Offset for $TC_DP5: $TC_ECP55[t,d] comparable to $TC_DP14[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP55[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
System variables
384
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_ECP55 [32000,32000]
Location-dependent setting correction to $TC_DP5
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP56 [32000,32000]
Location-dependent setting correction to $TC_DP6
DOUBLE
Description:
Offset for $TC_DP6: $TC_ECP56[t,d] comparable to $TC_DP15[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP56[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP57 [32000,32000]
Location-dependent setting correction to $TC_DP7
DOUBLE
Description:
Offset for $TC_DP7: $TC_ECP57[t,d] comparable to $TC_DP16[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP57[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
385
List of system variables
3.7 OEM user cutting edge data
$TC_ECP58 [32000,32000]
Location-dependent setting correction to $TC_DP8
DOUBLE
Description:
Offset for $TC_DP8: $TC_ECP58[t,d] comparable to $TC_DP17[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP58[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP59 [32000,32000]
Location-dependent setting correction to $TC_DP9
DOUBLE
Description:
Offset for $TC_DP9: $TC_ECP59[t,d] comparable to $TC_DP18[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP59[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP60 [32000,32000]
Location-dependent setting correction to $TC_DP10
DOUBLE
Description:
Offset for $TC_DP10: $TC_ECP60[t,d] comparable to $TC_DP19[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP60[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
386
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_ECP60 [32000,32000]
Location-dependent setting correction to $TC_DP10
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP61 [32000,32000]
Location-dependent setting correction to $TC_DP11
DOUBLE
Description:
Offset for $TC_DP11: $TC_ECP61[t,d] comparable to $TC_DP20[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP61[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP63 [32000,32000]
Location-dependent setting correction to $TC_DP3
DOUBLE
Description:
Offset for $TC_DP3: $TC_ECP63[t,d] comparable to $TC_DP12[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP63[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP64 [32000,32000]
Location-dependent setting correction to $TC_DP4
DOUBLE
Description:
Offset for $TC_DP4: $TC_ECP64[t,d] comparable to $TC_DP13[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP64[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
387
List of system variables
3.7 OEM user cutting edge data
$TC_ECP64 [32000,32000]
Location-dependent setting correction to $TC_DP4
DOUBLE
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP65 [32000,32000]
Location-dependent setting correction to $TC_DP5
DOUBLE
Description:
Offset for $TC_DP5: $TC_ECP65[t,d] comparable to $TC_DP14[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP65[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP66 [32000,32000]
Location-dependent setting correction to $TC_DP6
DOUBLE
Description:
Offset for $TC_DP6: $TC_ECP66[t,d] comparable to $TC_DP15[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP66[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
388
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.7 OEM user cutting edge data
$TC_ECP67 [32000,32000]
Location-dependent setting correction to $TC_DP7
DOUBLE
Description:
Offset for $TC_DP7: $TC_ECP67[t,d] comparable to $TC_DP16[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP67[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP68 [32000,32000]
Location-dependent setting correction to $TC_DP8
DOUBLE
Description:
Offset for $TC_DP8: $TC_ECP68[t,d] comparable to $TC_DP17[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP68[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP69 [32000,32000]
Location-dependent setting correction to $TC_DP9
DOUBLE
Description:
Offset for $TC_DP9: $TC_ECP69[t,d] comparable to $TC_DP18[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP69[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
389
List of system variables
3.8 Tool management monitoring data
$TC_ECP69 [32000,32000]
Location-dependent setting correction to $TC_DP9
DOUBLE
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP70 [32000,32000]
Location-dependent setting correction to $TC_DP10
DOUBLE
Description:
Offset for $TC_DP10: $TC_ECP70[t,d] comparable to $TC_DP19[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP70[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_ECP71 [32000,32000]
Location-dependent setting correction to $TC_DP11
DOUBLE
Description:
Offset for $TC_DP11: $TC_ECP71[t,d] comparable to $TC_DP20[t,d]
When the 'flat D number management' function is active, the syntax is as follows:
$TC_ECP71[d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
3.8
Tool management monitoring data
$TC_MOP1 [32000,32000]
Prewarning limit of tool life
DOUBLE
Description:
$TC_MOP1[t,d]
Prewarning limit for downtime
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
System variables
390
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.8 Tool management monitoring data
$TC_MOP1 [32000,32000]
Prewarning limit of tool life
DOUBLE
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOP2 [32000,32000]
Residual tool life
DOUBLE
Description:
$TC_MOP2[t,d]
Residual tool life
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOP3 [32000,32000]
Prewarning limit quantity
INT
Description:
$TC_MOP3[t,d]
Prewarning limit for workpiece count
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
391
List of system variables
3.8 Tool management monitoring data
$TC_MOP4 [32000,32000]
Residual workpieces
INT
Description:
$TC_MOP4[t,d]
Residual workpieces
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOP5 [32000,32000]
Prewarning limit for wear
DOUBLE
Description:
$TC_MOP5[t,d]
Prewarning limit for wear
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOP6 [32000,32000]
Residual wear
DOUBLE
Description:
$TC_MOP6[t,d]
Residual wear
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
392
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.8 Tool management monitoring data
$TC_MOP11 [32000,32000]
Specified tool life
DOUBLE
Description:
$TC_MOP11[t,d]
Specified tool life
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOP13 [32000,32000]
Specified workpiece count
INT
Description:
$TC_MOP13[t,d]
Specified workpiece count
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOP15 [32000,32000]
Specified wear
DOUBLE
Description:
$TC_MOP15[t,d]
Specified wear
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
mm
0.0
-1.8E+308
1.8E+308
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
393
List of system variables
3.9 OEM user monitoring data
3.9
OEM user monitoring data
$TC_MOPC1 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC1[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC2 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC2[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC3 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC3[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
System variables
394
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.9 OEM user monitoring data
$TC_MOPC3 [32000,32000]
-
INT
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC4 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC4[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC5 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC5[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC6 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC6[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
395
List of system variables
3.9 OEM user monitoring data
$TC_MOPC6 [32000,32000]
-
INT
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC7 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC7[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC8 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC8[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC9 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC9[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
System variables
396
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.9 OEM user monitoring data
$TC_MOPC9 [32000,32000]
-
INT
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC10 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC10[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC11 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC11[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC12 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC12[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
397
List of system variables
3.9 OEM user monitoring data
$TC_MOPC12 [32000,32000]
-
INT
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC13 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC13[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC14 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC14[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC15 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC15[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
System variables
398
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.9 OEM user monitoring data
$TC_MOPC15 [32000,32000]
-
INT
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC16 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC16[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC17 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC17[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC18 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC18[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
399
List of system variables
3.9 OEM user monitoring data
$TC_MOPC18 [32000,32000]
-
INT
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC19 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC19[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC20 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC20[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC21 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC21[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
System variables
400
List Manual, 10/2020, 6FC5397-6AP40-6BA4
List of system variables
3.9 OEM user monitoring data
$TC_MOPC21 [32000,32000]
-
INT
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC22 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC22[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC23 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC23[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC24 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC24[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
System variables
List Manual, 10/2020, 6FC5397-6AP40-6BA4
401
List of system variables
3.9 OEM user monitoring data
$TC_MOPC24 [32000,32000]
-
INT
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC25 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC25[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
$TC_MOPC26 [32000,32000]
-
INT
Description:
The type can be specified by machine data. INT is the default setting
$TC_MOPC26[t,d]
Index 1:
t: T number 1 - SLMAXTOOLNUMBER
Index 2:
d: Cutting edge number / D number 1 - SLMAXCUTTINGEDGENUMBER
Unit
Init value
Min
Max
-
0
-2147483648
2147483647
Read/Write properties:
TP
SA
TP/SA safety
NC-Variable
Safety
OEM-CC
Read:
X
-
7
X
7
-
Write:
X
-
7
X
7
-
Axis entry:
Overlap chan-
channel-specific
nel:
Scan mode:
Not classified
Link:
No restrictions
System variables
402
List Manual, 10/2020, 6FC5397-6AP40-6BA4

 

 

 

 

 

 

 