Fundamentals
4.5 Notes on "easyscreen.ini"
4.5
Notes on "easyscreen.ini"
As of SINUMERIK Operate V4.7, "easycreen.ini" has been extended by the entries described in
this chapter. The "easyscreen.ini" can be found in the [System siemens-directory]/cfg.
Help screen start position
Entry in "easyscreen.ini":
[GENERAL]
HlpPicFixPos=true
Note:
The start position of help displays is positioned at the configured pixel position independent of
the resolution (default=true).
Elongation behavior, default line height and line spacing
Entry in easyscreen.ini:
[GENERAL]
SymmetricalAspectRatio=false
DefaultLineHeight=18
DefaultLineSpacing=3
Notes:
• The "SymmetricalAspectRatio" entry determines whether the same aspect ratio is used in the
X and Y direction when adapting a configuration to a specific screen resolution.
- "false" (default): Fields and graphics are shortened in widescreen resolution in the Y
direction (asymmetrical elongation in relation to 640x480). For example, a square
configured in 640x480 is shortened vertically for a widescreen panel and becomes a
rectangle.
- "true": The same aspect ratio is used in the X and Y direction and fields and graphics retain
their originally configured proportions in relation to 640x480. For example, a square
configured in 640x480 remains a square in a widescreen panel.
• The entries "DefaultLineHeight" and "DefaultLineSpacing" can be used to specify the default
line height (default: 18 pixels) and the default line spacing (default: 3 pixels) in relation to
640x480. They only take effect when no Y position or height is specified in the configuration
for the position of the short text or the input/output field.
SINUMERIK Integrate Run MyScreens
44
Programming Manual, 10/2020, A5E40869575B AD
Fundamentals
4.5 Notes on "easyscreen.ini"
Cycles in the basic display Machine
• Entry to machine operating mode JOG via HS6 with the possibility to generate a cycle call into
the Machine main screen with section [JOBSHOPINTEGRATION]:
[JOBSHOPINTEGRATION]
Integration = true
or via the starting block in the configuration
LM("Screen1",,1)
PRESS(VS8)
GC("MOVE_RIDE") ; cycle call is being generated
EXIT
END_PRESS
• Retention of the operate menus with section [Integration]:
If the dialog only includes vertical softkeys, the horizontal standard softkey bar incl. the start
softkey is retained when the dialog is displayed. If the dialog contains horizontal and vertical
softkeys, the horizontal bar from the dialog replaces the horizontal bar with the start softkey.
[Integration]
OperateMenusEnabled = true
Resolution-dependent screen position: Form panels
Entry in "easyscreen.ini":
[640x480]
MyPanel = x:=0, y:=220, width:=340, height:=174
[800x480]
MyPanel = x:=0, y:=220, width:=420, height:=174
Notes:
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
45
Fundamentals
4.5 Notes on "easyscreen.ini"
The screen position can be defined as follows:
• The screen position can be specified in "Pixels in relation to 640x480".
Example:
//M(MyMask/"MyCaption"/"\\myhelp.png"/0,219,335,174)
• The screen position can be coupled to the resolution-dependent position of a form panel
from an Operate standard screen layout, e.g. "FormPanel4" ("auxiliary functions") from the
screen layout "slmastandardscreenlayout.SlMaStandardScreenLayout" of the "Machine" area
//M(MyMask/"MyCaption"/"\
\myhelp.png"/"slmastandardscreenlayout.SlMaStandardScreenLayout.FormPanel4"
)
It is therefore easy to superimpose standard forms from Operate or position Easyscreen
screens precisely at their position.
Example:
//M(Mask/"Mask"//"slstandardscreenlayout.SlStandardScreenLayout.LowerForm")
Any other screen layout can also be used.
• The screen position can be coupled to a self-defined, resolution-dependent definition of form
panels in the "easyscreen.ini" file.
Example:
//M(MyMask/"MyCaption"/"\\myhelp.png"/"MyPanel")
SINUMERIK Integrate Run MyScreens
46
Programming Manual, 10/2020, A5E40869575B AD
Fundamentals
4.6 Notes for personnel changing over to "Run MyScreens"
4.6
Notes for personnel changing over to "Run MyScreens"
Note
When using HMI Operate in the NCU, note that all file names are saved in lower case letters on
the CF card (com, png, txt).
Note
Make sure that the coding is set to UTF-8 in the editor that you are using when saving the
configuration and language files.
Image files
Always save image files in the PNG format "*.png".
The data must be saved, e.g. for OEM modifications, under
[System oem-directory]/ico/[resolution].
Further information can be found in Chapter Using display images/graphics (Page 67).
Adapting the configuration file
Check your configuration files regarding the following points:
• Compare the start softkeys with the currently permissible softkeys and adapt them, if
required.
• Rename the integrated image files corresponding to the "Image files" point above.
The data is stored, e.g. for OEM modifications, in the following directory:
[System oem-directory]/proj
[System user-directory]/proj A
[System addon-directory]/proj
Adapting the help files
All help files must be saved in UTF-8. Check your existing files, and resave them accordingly with
a suitable editor.
The HTML files are saved in the following directory, e.g. for English:
[System oem-directory]/hlp/eng
[System user-directory]/hlp/eng
[System addon-directory]/hlp/eng
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
47
Fundamentals
4.6 Notes for personnel changing over to "Run MyScreens"
You must create the directories for additional languages corresponding to the language codes.
Checking the "Run MyScreens" license
Check whether the number of dialogs that you have entered exceeds the basic scope of a
maximum of five dialogs.
To expand the number of dialogs, you require one of the following software options:
• SINUMERIK 828D/840D sl, SINUMERIK Integrate Run MyScreens
(6FC5800-0AP64-0YB0)
• SINUMERIK 840D sl, SINUMERIK Integrate Run MyScreens + Run MyHMI
(6FC5800-0AP65-0YB0)
• SINUMERIK 840D sl, SINUMERIK Integrate Run MyHMI / 3GL
(6FC5800-0AP60-0YB0)
• SINUMERIK 840D sl, SINUMERIK Integrate Run MyHMI / WinCC
(6FC5800-0AP61-0YB0)
SINUMERIK Integrate Run MyScreens
48
Programming Manual, 10/2020, A5E40869575B AD
Fundamentals
4.7 Extended configuration syntax
4.7
Extended configuration syntax
As of SINUMERIK Operate V4.7, a simplified syntax is available for the definition of screens,
variables, softkeys and for table columns. Reading and servicing are improved with this
alternative syntax. The properties and attributes can be specified in any order, empty entries are
omitted. Instead of with round brackets "(" and ")" as in the previous syntax, the listing of the
properties and attributes is now enclosed in curly brackets "{" and "}".
The properties and attributes are specified as follows:
{<Name> = <Value>, <Name> = <Value>, …}
The previous syntax remains compatible.
Extended syntax for the definition of screens
//M {<Mask name> [,HD=<Title>] [,HLP=<Graphic>] [,X=<X position>] [,Y=<Y position>]
[,W=<Width>] [,H=<Height>] [,VAR=<> System or user variable] [,HLP_X=<X position help
screen] [,HLP_Y=<Y position help screen>] [,CM=<Column alignment>] [,CB= Response when
opening the dialog] [,XG=<Interpret help screen as X3d graphic>] [,PANEL=<Name of the
linked FormPanel>][,MC=<Mask backg34round color:>][,HD_AL=<Alignment of the mask
header>] [,LANGFILELIST=<List of the mask-specific language files>]}
Example:
//M{VariantTest, HD="My Mask"}
Extended syntax for the definition of variables
DEF <Variable name> = {[TYPType] [,MIN=<Minimum value>] [,MAX=<Maximum value>]
[,TGL=<Toggle values>] [,VAL=<Preassignment>] [,LT=<Long text>] [,ST=<Short text>]
[,GT=<Graphic text>] [,UT=<Unit text>] [,TT=<ToolTip text>] [,TG=<Toggle option>]
[,WR=<Input mode>] [,AC=<Access level>] [,AL=<Text alignment>] [,FS=<Font size>]
[,LI=<Limit value handling>] [,UR=<Refresh rate>] [,CB=<Text align when opening the dialog>]
[,HLP=<Help screen>] [,VAR=<System or user variable>] >] [,TXT_X=<X position short text>]
[,TXT_Y=<Y position short text>] [,TXT_W=<Width short text>] [,TXT_H=<Height short text>]
[,X=<X position input/output field>] [,Y=<Y position input/output field>] [,W=<Width input
output field>] [,H=<Height input/output field>] [,UT_DX=<Distance between input field and
unit field>] [,UT_W=<Width unit field>] [,BC=<Background color input/output field>]
[,FC=<Foreground color input/output field>] [,BC_ST=<Background color short text>]
[,FC_ST=<Foreground color short text>] [,BC_GT=<Background color graphic text>]
[,FC_GT=<Foreground color graphic text>] [,BC_UT=<Background color unit text>]
[,FC_UT=<Foreground color unit text>] [,SC1=<Signal color 1 for progress bar>] [,SC2=<Signal
color 2 for progress bar>] [,SVAL1=<Threshold value 1 for progress bar>] [,SVAL2=<Threshold
value 2 for progress bar>] [,DT=<Display type>] [,DO=<Display alignment>] [,OHLP=<Online
help>][,LINK_TGL=<Name of the linked toggle v]}
Examples:
DEF MyVar5={TYP="R2", ST="MyVar5", VAL=123.4567, OHLP="myhelp.html", MIN=100.1,
MAX=200.9}
DEF MyVar2={TYP="I", TGL="*1,2,3", VAL=1}
DEF MyVar3={TYP="R2", TGL="*0=""Off"", 1=$80000", VAL=1}
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
49
Fundamentals
4.7 Extended configuration syntax
DEF MyVar4={TYP="R2", TGL="*MyArray",VAL=1}
DEF MyVar1={TYP="R2", TGL="%grid99", X = 0, W=300, H=200}
DEF MyVar6={TYP="R2", TGL="+$80000", VAR="$R[10]", ST="Text offset"}
Extended syntax for the definition of softkeys
SK = {[ST=<Label>] [,AC=<Access level>] [,SE=<Status>]}
Examples:
HS1={ST="""MySk""", AC=6, SE=1}
HS3={ST="SOFTKEY_CANCEL"}
HS5={ST="[$81251,""\\sk_ok.png""]"}
HS8={ST="[""Test"",""\\sk_ok.png""]"}
Extended syntax for the definition of table columns
{[TYP=<Type>] [,MIN=<Minimum value>] [,MAX=<Maximum value>] [,LT=<Long text>]
[,ST=<Short text>] [,WR=<Input mode>] [,AC=<Access level>] [,AL=<Text alignment>]
[,FS=<Font size>] [,LI=<Limit value handling>] [,UR=<Refresh rate>] [,HLP=<Help screen>]
[,VAR=<System or user variable>] >] [,W=<Column width>] [,OF1=<Offset1>]
[,OF2=<Offset2>] [,OF3=<Offset3>]}
Example:
DEF MyGridVar={TYP="R", TGL="%MyGrid1", X=10, W=550, H=100}
//G(MyGrid1/0/5)
{TYP="I", ST="Index", WR=1, VAR="1", W=80, OF1=1}
{TYP="S", LT="LongText2", ST="Text", WR=1, VAR="$80000", AL=2, W=330, OF1=1}
{TYP="R3", LT="LongText1", ST="R9,R11,R13,R15", WR=2, VAR="$R[1]", W=110, OF1=2}
//END
SINUMERIK Integrate Run MyScreens
50
Programming Manual, 10/2020, A5E40869575B AD
Fundamentals
4.8 SmartOperation and MultiTouch operation
4.8
SmartOperation and MultiTouch operation
You have the following setting options for specific adjustment to SmartOperation and for
MultiTouch operation:
• Automatic adjustment of the field height and field width to the so-called minimum usable
field size and the line spacing (mask attribute MA).
• Optimized and pixel-precise stretching of the fields for higher resolutions (mask attribute PA).
• Setting of the field height and line spacing proportional to the font (mask attribute FA).
• Allows free scrolling so that the input field is not covered by the virtual keyboard (mask
attribute KM).
Further details can be found in Chapter Defining dialog properties (Page 55), Section
"Programming".
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
51
Fundamentals
4.8 SmartOperation and MultiTouch operation
SINUMERIK Integrate Run MyScreens
52
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5
5.1
Structure and elements of a dialog
5.1.1
Defining a dialog
Definition
A dialog is part of a user interface consisting of a display line, dialog elements and/or graphics,
an output line for messages and 8 horizontal and 8 vertical softkeys.
Dialog elements are:
• Variables
- Limits/toggle field
- Default setting of variables
• Help display
• Texts
• Attributes
• System or user variable
• Position of short text
• Position of input/output field
• Colors
Dialog properties:
• Header
• Graphic
• Dimension
• System or user variable
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
53
Dialogs
5.1 Structure and elements of a dialog
• Graphic position
• Attributes
① Machine status display ("header")
② Dialog element
③ 8 vertical softkeys
④ 8 horizontal softkeys
⑤ Output of diagnostic messages
⑥ Graphic
⑦ Dialog
⑧ Header line of the dialog with header and long text
Figure 5-1
Structure of the dialog
Overview
The definition of a dialog (definition block) is basically structured as follows:
Definition block
Comment
Chapter reference
//M...
;Dialog start identifier
DEF Var1=...
;Variables
Variables (Page 87)
HS1=(...)
;Softkeys
Defining softkey menus (Page 68)
PRESS(HS1)
;Method start identifier
LM...
;Actions
Methods (Page 132)
END_PRESS
;Method end identifier
//END
;Dialog end identifier
SINUMERIK Integrate Run MyScreens
54
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.1 Structure and elements of a dialog
Within the dialog definition block, various variables that appear as dialog elements in the dialog,
as well as horizontal and vertical softkeys, are defined first. Different types of actions are then
configured in methods.
Note
In operating area "Machine", for a dialog change, the following sequence should be observed:
Under the precondition that the dimensions of the following mask are smaller than the previous
mask - or the position of the following mask is different than the previous mask, dialog change
only functions if the following mask is exited before returning to the first mask, and only then is
the first mask reloaded.
5.1.2
Defining dialog properties
Description
The properties of the dialog are defined in the start identifier line of the dialog.
① Machine status display ("header")
② Graphic
③ Dialog
④ Header line of the dialog with header and long text
Figure 5-2
Dialog properties
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
55
Dialogs
5.1 Structure and elements of a dialog
Programming
Syntax:
//M(Identifier/[Title]/[Graphic]/[Dimension]/[System or user variable]/[Position graphic]/[Attribute]/List of the
mask-specific language files)
See also Chapter Extended configuration syntax (Page 49).
Description:
Defines a dialog
SINUMERIK Integrate Run MyScreens
56
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.1 Structure and elements of a dialog
Parameter:
Identifier
Name of the dialog
Header
Dialog header as text or call for text (e.g. $85011) from a language-specific
text file.
Graphic
Graphics file with path in double quotation marks.
Dimension
Position and size of the dialog in pixels (distance from left-hand side, dis-
tance from top, width, height), in relation to the upper left-hand corner of
the screen. The entries are separated by a comma.
System or user variable
System or user variable to which the current cursor position is assigned. The
NC or PLC can be provided with the cursor position via the system or user
variable. The first variable has index 1. The order corresponds to the config-
uration order of the variables.
Graphic position
Position of the graphic in pixels (distance from left-hand side, distance from
top), in relation to the upper left-hand corner of the dialog. The entries are
separated by a comma.
Attributes
The specifications of the attributes are separated by a comma.
Possible attributes are:
CM
Column mode: Column alignment
CM0
Default setting: The column distribution is carried out separately for each
line.
CM1
The column distribution of the line with the most columns applies to all lines.
CB
CHANGE block: Response when dialog is opened: cb attributes specified for
a variable in a variables definition take priority over the default setting in the
dialog definition.
See also AUTOHOTSPOT.
CB0
Default setting: All CHANGE blocks associated with the dialog are processed
when it is opened.
CB1
CHANGE blocks are then only processed if the relevant value changes.
XG
Integration of an X3D animation as help display (only in the machining step
programming).
Example:
//M(Meas/
$85605/"myx3dhelpfile.hmi,,Z_Animation,,G17"///30,10/
XG1)
XG0
Default setting = 0
XG1
The mask attribute XG must already be set to 1 in the mask definition, a
change during runtime is not possible.
Note:
The specification in the mask property HLP must also be set accordingly.
AL
The alignment of the mask header can be influenced with the mask attribute
AL.
Example:
Central setting of the "Set password" window header:
//M(MY_PWD_SET/”Set password”//"EasyPwdModalLayout"//
AL2)
AL0
Left-justified, default
AL1
Right-justified
AL2
Centered
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
57
Dialogs
5.1 Structure and elements of a dialog
KM
Freely scrolling in the mask (SlGfwScrollArea), if the virtual keyboard is to be
displayed for MultiTouch, can be influenced as follows:
• In the mask definition line with mask attribute "KM" (KeyboardMode)
Example:
//M(MyMTMask/"MultiTouch Mask"/////KM1)
• As global setting for all Run MyScreens masks in the "easyscreen.ini"
Example:
[GENERAL]
DefaultVirtualKeyboardMode=1
Note:
If, when configuring the masks, the mask attribute KM is explicitly set, then
this has a higher priority than the global setting in "easyscreen.ini".
(See also Chapter SmartOperation and MultiTouch operation (Page 51))
KM1
Free scrolling active (default)
KM0
Free scrolling inactive
PG
Alignment and appearance of the window title in conjunction with PNG
images (only effective in the editor!)
Example:
//M(MyPg1SampleMask/"My PG1 Sample Mask"/////PG1)
PG0
(Default)
PG1
Alignment and appearance of the window title in conjunction with PNG
images
Path specification (on the far left), mask name (on the right)
The display of the long text is no longer possible in this mode. Alternatively,
you can work with tooltips.
MA
Automatic adjustment of the field height for MultiTouch operation (Mutli-
Touch Adjustment)
If required, the adjusment for a MultiTouch operator panel includes the nec-
essary enlargement to the so-called minimum usable size (width, height) of
the fields (exceptions: progress bar, animated GIF, CustomWidget) and the
line spacing.
The MultiTouch adjustment can be made
• globally for all Run MyScreens mask in "easyscreen.ini", e.g.
[GENERAL]
DefaultMultiTouchAdjustmentLevel=1
• or mask-specifically in the mask definition line with the mask property
"MA" in order to overwrite the global setting in "easyscreen.ini", e.g.
//M(MyMTMask/"MultiTouch Mask"/////MA1)
If the mask attribute MA is set explicitly in the mask configuration, then this
has a higher priority than the global setting in "easyscreen.ini".
(See also Chapter SmartOperation and MultiTouch operation (Page 51))
MA0
There is no adjustment
MA1
Only those fields are adjusted for which no spacing from the top and/or field
height/width has been configured - i.e. the fields that use default positions
and therefore for which Run MyScreens calculates the spacing from the top
and/or field height/width. (Default)
SINUMERIK Integrate Run MyScreens
58
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.1 Structure and elements of a dialog
MA2
All fields are adjusted irrespective of the configured field sizes.
PA
Optimized and pixel-precise stretching of the fields for higher resolutions
(Pixel Fine Adjustment)
Previously all field positions were calculated in relation to 640x480 and then
zoomed with the appropriate horizontal and vertical stretch factors. This
process has the disadvantage that rounding errors can occur with "unfavor-
able stretch factors". For example, the field height or line spacing can "jump"
by a pixel from line-to-line. The "Pixel Fine Adjustment" mode can be used to
prevent this as the field positions are determined directly in the current res-
olution.
//M(MyMask/"My Mask"/////PA1)
This setting can also be made globally for all Run MyScreens masks in "easy-
screen.ini", e.g.
[GENERAL]
DefaultPixelFineAdjustment=1
If the mask attribute PA is set explicitly in the mask configuration, it has a
higher priority than the global setting in "easyscreen.ini".
If a mask is displayed with Font Adjustment = FA1, then the Pixel Fine Ad-
justment mode is also automatically active for this mask.
(See also Chapter SmartOperation and MultiTouch operation (Page 51))
PA0
Stretching as previously, i.e. the positions are calculated in relation to
640x480 and then stretched.
(For compatibility reasons: Default)
PA1
Optimized and pixel-precise stretching of the fields for higher resolutions
FA
Field height and line spacing proportional to the font (Font Adjustment)
This setting can also be made globally for all Run MyScreens masks in "easy-
screen.ini", e.g.
[GENERAL]
DefaultFontAdjustment=1
If the mask attribute FA is set explicitly in the mask configuration, then this
has a higher priority than the global setting in "easyscreen.ini".
The settings for the DefaultLineHeight and DefaultLineSpacing have no sig-
nificance when Font Adjustment mode is active.
(See also Chapter SmartOperation and MultiTouch operation (Page 51))
FA0
Field height and line spacing are stretched as previously. (For compatibility
reasons: Default)
FA1
Field height and line spacing are set proportional to the font (automatically
sets mask attribute PA=1)
FA2
Same as FA1, but the X coordinate and the field width are also stretched
proportionally to the font
(Automatically sets mask attribute PA=1)
(Only possible in conjunction with attribute XG=1!)
NT
Navigation Type
NT0
NT0 = standard mode
The navigation is analogous to the masks of the operating area in which Run
MyScreens mask is integrated. This means in the cycle masks in the editor,
navigation is line-oriented (see NT2), in all other "normal" masks, it is a geo-
metrical (see NT1).
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
59
Dialogs
5.1 Structure and elements of a dialog
NT1
Geometrical navigation (top, bottom, left, right), until the borders of the
mask are reached (standard in a normal Run MyScreens environment, e.g.
area "Custom")
NT2
Line-oriented, i.e. within the line to the right until the end of the line is
reached (standard, in the cycle masks of the editor)
NR
Navigation direction when pressing the Enter key (Return Navigate Direction)
NR0
NR0 = off (default), i.e. when pressing the Enter key, navigation is realized
within the mask in a tabular sequence (standard in the normal Run
MyScreens environment)
NR1
When pressing the Enter key, navigation is the same as when pressing the up
arrow key
NR2
As for NR1, however, downward
NR3
As for NR1, however, to the left
NR4
As for NR1, however, to the right
TA
Tooltip alignment
TA0
Automatic (default)
TA1
Left
TA2
Right
TA3
Top
TA4
Bottom
TA5
Top left
TA6
Bottom left
TA7
Top right
TA8
Bottom right
MC
Mask backg34round color (mask color)
Example:
Set mask backg34round color blue (= 6)
//M(MyMask/"MyMask"//////6)
or
PRESS(HS1)
MC=6
END_PRESS
List of the mask-specific lan-
separated by a comma
guage files
Accessing the dialog properties
Read and write access to the following dialog properties is permitted within methods (e.g. PRESS
block).
• HD = Header
• HLP = Help display
• VAR = System or user variable
• MC = Mask backg34round color
• CM = Column alignment (read-only)
SINUMERIK Integrate Run MyScreens
60
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.1 Structure and elements of a dialog
• CB = Behavior when opening (read-only)
• XG = Integration of X3d (read-only)
• AL = Mask header alignment (read-only)
Example
Figure 5-3 "Example 2: showing graphic"
//S(Start)
HS7=("Example", se1, ac7)
PRESS(HS7)
LM("Mask2")
END_PRESS
//END
//M(Mask2/"Example 2 : showing graphic"/"example.png")
HS1=("new%nHeader")
HS2=("")
HS3=("")
HS4=("")
HS5=("")
HS6=("")
HS7=("")
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
61
Dialogs
5.1 Structure and elements of a dialog
HS8=("")
VS1=("")
VS2=("")
VS3=("")
VS4=("")
VS5=("")
VS6=("")
VS7=("")
VS8=("")
PRESS(HS1)
Hd= "new Header"
END_PRESS
//END
See also
Programming example for the "Custom" area (Page 284)
5.1.3
Defining dialog elements
Dialog element
The term "dialog element" refers to the visible part of a variable, i.e. short text, graphics text,
input/output field, unit text and tooltip. Dialog elements fill lines in the main body of the dialog.
One or more dialog elements can be defined for each line.
SINUMERIK Integrate Run MyScreens
62
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.1 Structure and elements of a dialog
Variable properties
All variables are valid in the active dialog only. Properties are assigned to a variable when it is
defined. The values of dialog properties can be accessed within methods (e.g. a PRESS method).
① Header line of the dialog with header and long text
② Dialog element
③ Short text
④ Input/output field
⑤ Graphic text
⑥ Unit text
⑦ Main body of the dialog
Figure 5-4
Elements of a dialog
Programming - Overview
The single parameters to be separated by commas are enclosed in round brackets:
DEF [identifier] =
Identifier = Name of variable
Variable type
/[Limit values or toggle field]
/[Default]
/[Texts (Long text, Short text|Image, Graphic text, Unit text)]
/[Attributes]
/[Help display]
/[System or user variable]
/[Position of short text]
/[Position of I/O field(Left, Top, Width, Height)]
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
63
Dialogs
5.1 Structure and elements of a dialog
/[Colors]
/[online help] (Page 77)
See also
Variable parameters (Page 98)
5.1.4
Defining dialogs with multiple columns
Overview
Multiple variables can also be represented in a dialog on one line. In this case, the variables are all
defined in the configuration file on a single definition line.
DEF VAR11 = (S///"Var11"), VAR12 = (I///"Var12")
To make individual variables in the configuration file more legible, the definition lines can be
wrapped after every variables definition and following comma.
The key word "DEF" always indicates the beginning of a new line:
DEF Tnr1=(I//1/"","T ",""/wr1///,,10/20,,50),
TOP1=(I///,"Type="/WR2//"$TC_DP1[1,1]"/80,,30/120,,50),
TOP2=(R3///,"L1="/WR2//"$TC_DP3[1,1]"/170,,30/210,,70),
TOP3=(R3///,"L2="/WR2//"$TC_DP4[1,1]"/280,,30/320,,70),
TOP4=(R3///,"L3="/WR2//"$TC_DP5[1,1]"/390,,30/420,,70)
DEF Tnr2=(I//2/"","T ",""/wr1///,,10/20,,50),
TOP21=(I///,"Typ="/WR2//"$TC_DP1[2,1]"/80,,30/120,,50),
TOP22=(R3///,"L1="/WR2//"$TC_DP3[2,1]"/170,,30/210,,70),
TOP23=(R3///,"L2="/WR2//"$TC_DP4[2,1]"/280,,30/320,,70),
TOP24=(R3///,"L3="/WR2//"$TC_DP5[2,1]"/390,,30/420,,70)
Note
When configuring multi-column dialogs, please observe that a large number of columns might
slow down the system!
SINUMERIK Integrate Run MyScreens
64
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.1 Structure and elements of a dialog
5.1.5
Password dialogs
Using the standard password dialogs
You can integrate the following predefined password dialogs in the screen configuration:
• Set password
Figure 5-5
Set password dialog
• Change password
Figure 5-6
Change password dialog
• Delete password
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
65
Dialogs
5.1 Structure and elements of a dialog
Figure 5-7
Delete password dialog
Note
Password functionality is provided with these dialogs. The dialogs do not correspond to the
dialogs of SINUMERIK Operate.
The dialogs can be called either via the Load softkey (LS) function or the Load mask (LM)
function:
1. Call via the Load softkey (LS) function:
LS("Passwd","slespasswd.com",1)
Extension of the vertical softkeys:
- Softkey 1: Set password
- Softkey 2: Change password
- Softkey 3: Delete password
2. Alternatively, the three masks can be directly jumped to by calling the (LM) function:
- Set password: LM("PWD_SET", "slespasswd.com",1)
- Change password: LM("PWD_CHG", "slespasswd.com",1)
- Delete password: LM("PWD_CLEAR", "slespasswd.com",1)
SINUMERIK Integrate Run MyScreens
66
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.1 Structure and elements of a dialog
5.1.6
Using display images/graphics
Use of graphics
A distinction is made between:
• Figures/graphics in the graphic area
• Help displays illustrating, for example, individual variables, which are superimposed in the
graphic area.
• More help displays can be configured instead of short text or an input/output field, which you
position where you like.
Storage locations
The image matching the resolution of the connected monitor is searched for in the associated
resolution directories in the following sequence:
[System user-directory]/ico/ico<Resolution>
[System oem-directory]/ico/ico<Resolution>
[System addon-directory]/ico/ico<Resolution>
If the image is not displayed or not found, copy it into one of the following directories for a
resolution of 640 x 480 pixels:
[System user-directory]/ico/ico640
[System oem-directory]/ico/ico640
[System addon-directory]/ico/ico640
Note
The images are positioned proportionally for the different panel resolutions
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
67
Dialogs
5.2 Defining softkey menus
5.2
Defining softkey menus
Definition
The term softkey menu is used to refer to all the horizontal and vertical softkeys displayed on a
mask. In addition to the existing softkey menus, it is possible to define other menus, which
partially or completely overwrite the existing menus.
The names of the softkeys are predefined. Not all softkeys need to be assigned.
HSx x 1 - 8, Horizontal softkeys 1 to 8
VSy y 1 - 8, Vertical softkeys 1 to 8
The definition of a softkey menu (softkey menu definition block) is basically structured as
follows:
Definition block
Comment
Section reference
//S...
;Start identifier of softkey menu
HSx=...
;Define softkeys
PRESS(HSx)
;Method start identifier
See Chapter Methods (Page 132)
LM...
;Actions
END_PRESS
;Method end identifier
//END
;End identifier of softkey menu
Description
Properties are assigned to softkeys during definition of the softkey menu.
Programming
Syntax:
//S(Identifier)
;Start identifier of softkey menu
//END
;End identifier of softkey menu
See also Section Extended configuration syntax (Page 49).
Description:
Defines the softkey menu
Parameters:
Identifier
Name of the softkey menu
Text or image file name
Syntax:
SK = (Text[, access level][, Status][, Alignment of the softkey image][, text align-
ment referred to the softkey image])
Description:
Define softkey
Parameters:
SK
Softkey, e.g. HS1 to HS8, VS1 to VS8
SINUMERIK Integrate Run MyScreens
68
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.2 Defining softkey menus
Text
Enter text
Image file name
"\\my_pic.png"
or via separate text file $85199, e.g. with the following
text in the (language-specific) text file: 85100 0 0 "\
\my_pic.png".
The image size which can be displayed on a softkey de-
pends on the OP used:
OP 08:
640 x 480 mm → 25 x 25 pixels
OP 010:
640 x 480 mm → 25 x 25 pixels
OP 012:
800 x 600 mm → 30 x 30 pixels
OP 015:
1024 x 768 mm → 40 x 40 pixels
OP 019:
1280 x 1024 mm → 72 x 72 pixels
Access level
ac0 to ac7 (ac7: default)
Status
se1: visible (default)
se2: disabled (gray text)
se3: displayed (last softkey used)
Alignment of the soft-
PA (PictureAlignment)
key image
Valid values:
0: Left
1: Right
2: Centered
3: Top (default)
4: Bottom
Text alignment in re-
TP (TextAlignedToPicture)
lation to the softkey
Valid values:
image
0: Text is not aligned to the image
1: Text is aligned to the image (default)
Note
Enter %n in the softkey text to create a line break.
A maximum of 2 lines with 9 characters each are available.
Assigning access level
Operators can only access information on this access level and lower access levels (see also
AUTOHOTSPOT).
Example
//S(Menu1)
; Start identifier of softkey menu
HS1=("NEW", ac6, se2)
; Define softkey HS1, assign the label "NEW", protec-
tion level 6, and the status "disabled"
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
69
Dialogs
5.2 Defining softkey menus
HS2=("\\image1.png")
; Assign a softkey to the graphic
HS3=("Exit")
HS4=(["Confirm","\\sk_ok.png"],PA0,TP1)
; Softkey with text and graphic, Text="Confirm", Im-
age="sk_ok.png", Alignment of the softkey image: Left,
text is aligned to the image
VS1=("sub mask")
VS2=($85011, ac7, se2)
; Define softkey VS2, assign the text from the lan-
guage file, protection level 1, and the status "disa-
bled"
VS3=("Cancel", ac1, se3)
; Define softkey VS3, assign the label "Cancel", pro-
tection level 1 and the status "highlighted"
VS4=("OK", ac6, se1)
; Define softkey VS4, assign the label "OK", protec-
tion level 6 and the status "visible"
VS5=(SOFTKEY_CANCEL,,se1)
; Define cancel standard softkey VS5 and assign the
status "visible"
VS6=(SOFTKEY_OK,,se1)
; Define OK standard softkey VS6 and assign the status
"visible"
VS7=(["\\image1.png","OEM text"],,se1)
; Define softkey VS7, assign an image, assign the la-
bel "OEM Text" and the status "visible"
VS8=(["\\image1.png",$83533],,se1)
; Define softkey VS8, assign an image, assign text
from language file and the status "visible"
PRESS(HS1)
; Method start identifier
HS1.st=" Calculate"
; Assign a label text to the softkey
END_PRESS
; Method end identifier
PRESS(RECALL)
; Method start identifier
LM("Screen21")
; Load dialog
END_PRESS
; Method end identifier
//END
; End identifier of softkey menu
5.2.1
Changing softkey properties during runtime
Description
The softkey properties Text, Access Level and Status can be changed in the methods during
runtime.
SINUMERIK Integrate Run MyScreens
70
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.2 Defining softkey menus
Programming
Syntax:
SK.st = "Text"
;Softkey with label
SK.ac = Access level
;Softkey with protection level
SK.se = Status
; Softkey with status
SK.pa = "Alignment of the softkey image"
;Softkey with image
SK.tp = "Text alignment in relation to the soft-
;Softkey with image and label
key image"
Description:
Assign properties
Parameter:
Text
Label text in inverted commas
Access level
Range of values: 0 ... 7
Status
1:
Visible and operator-controllable
2:
Disabled (gray text)
3:
Highlighted (last softkey used)
Alignment of the
0:
Left
softkey image
1:
Right
2:
Centered
3:
Top (default)
4:
Bottom
Text alignment in
0:
Text is not aligned to the image
relation to the
1:
Text is aligned to the image (default)
softkey image
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
71
Dialogs
5.2 Defining softkey menus
Example
Figure 5-8
Example 3: Graphics and softkeys
//S(Start)
HS7=("Example", ac7, se1)
PRESS(HS7)
LM("Maske3")
END_PRESS
//END
//M(Maske3/"Example 2: showing graphic"/"example.png")
HS1=("")
HS2=("")
HS3=("")
HS4=("")
HS5=("")
HS6=("")
HS7=("")
HS8=("")
VS1=("")
VS2=("")
SINUMERIK Integrate Run MyScreens
72
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.2 Defining softkey menus
VS3=("")
VS4=("\\sp_ok.png",,SE1)
VS5=(["\\sp_ok_small.png","OEM Text"],,SE1)
VS6=("")
VS7=(SOFTKEY_OK,,SE1)
VS8=(SOFTKEY_CANCEL,,SE1)
PRESS(VS4)
EXIT
END_PRESS
PRESS(VS5)
EXIT
END_PRESS
PRESS(VS7)
EXIT
END_PRESS
PRESS(VS8)
EXIT
END_PRESS
//END
5.2.2
Language-dependent text
Overview
Language-dependent texts are used for:
• Softkey labels
• Headings
• Help texts
• Any other texts
The language-dependent texts for dialogs are stored in text files.
The text files are stored in the following directories:
• [System user-directory]/lng
• [System oem-directory]/lng
• [System addon-directory]//lng
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
73
Dialogs
5.2 Defining softkey menus
Note
The text files must be saved in the same way as the project files.
For example:
[System user-directory]/lng/[Text file]
[System user-directory]/proj/[Configuration file]
alsc.txt
Language-dependent texts for the Siemens standard cycles
almc.txt
Language-dependent texts for the Siemens measuring cycles
The text files used during program runtime are specified in the "easyscreen.ini" file:
[LANGUAGEFILES]
LngFile03 = user.txt
;->user<_xxx>.txt (e.g.: user_eng.txt)
In this instance, the "user.txt" file has been chosen as an example of a text file. The name can
always be freely selected. Depending on the language of the texts within the file, the relevant
language code must be added according to the following syntax. An underscore followed by the
relevant language identifier is added after the name e.g. "user_eng.txt".
Note
You must not use LngFile01 and LngFile02 for user texts because they are already assigned in the
standard "easyscreen.ini".
See also
AUTOHOTSPOT
Mask-specific language files
In order to avoid overlaps for the number ranges used in the language files, only certain
language files can be used in a specific mask.
This is the reason that the language files to be used are listed in the mask definition line,
separated by a comma. The file listed at the last location has the highest priority (analogous to
the logic in "easyscreen.ini").
All of the language-dependent texts used in the mask are predominantly searched for in these
language files. If the text is not found in these, then a search is made in text files configured in
"easyscreen.ini".
SINUMERIK Integrate Run MyScreens
74
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.2 Defining softkey menus
If no language files have been defined in the mask, then a search is only made in the language
files specified in "easyscreen.ini".
Note
The English language file is used (default) if a language file is not available in the currently
selected language.
Examples:
//M(MyMask/$85597///// //"mytexts.txt, general.txt, mask.txt")
DEF ….
You can also use this procedure for the start softkeys:
//S(Start, "mytexts.txt, general.txt, mask.txt")
VS1=($85597)
PRESS(VS1)
LM("MyMask","masks.com")
END_PRESS
Format of text files
The text files must be saved in UTF-8 format.
Note
Make sure that the coding is set to UTF-8 in the editor that you are using when saving the
configuration and language files.
Format of a text entry
Syntax:
8xxxx 0 0 "Text"
Description:
Assignment between text number and text in the file
Parameters:
xxxx
85,000 to 89,999
Text identification number range reserved for
users. You must assign unique numbers.
900,000 to 999,999
"Text"
Text that appears in the dialog
%n
Control characters in the text for creating a line
break
Parameters 2 and 3 are separated by blanks and act as control characters for alarm text output.
To ensure that the text format is identical to that of the alarm texts, you must set zero.
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
75
Dialogs
5.2 Defining softkey menus
Examples of language-dependent texts:
85000 0 0 "Retraction plane"
85001 0 0 "Drilling depth"
85002 0 0 "Pitch"
85003 0 0 "Pocket radius"
SINUMERIK Integrate Run MyScreens
76
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.3 Configuring the online help
5.3
Configuring the online help
5.3.1
Overview
In addition to the existing extensive online help, you also have the option of generating a
manufacturer-specific online help and then linking this into SINUMERIK Operate.
This online help is generated in the HTML format, i.e. it comprises HTML documents that are
linked with one another. The subject being searched for is called in a separate window from a
contents or index directory. Similar to a document browser (e.g. Windows Explorer), a list of
possible selections is displayed in the left-hand half of the window and when you click on the
required subject, the explanation is displayed in the right hand half of the window.
Context sensitive selection of online help pages is not possible.
Procedure
1. Generating HTML files
2. Generating a help book
3. Integrating the online help in SINUMERIK Operate
4. Saving help files
Other application cases
Online help for the following OEM-specific expansions can be created and used to supplement
the SINUMERIK Operate online help system:
• Online help for cycles and/or M functions of the machine manufacturer which extend the
programming options for SINUMERIK control systems. This online help is called in just the
same way as the SINUMERIK Operate online help "Programming".
• Online help for OEM-specific variables of the machine manufacturer. This online help is
called from the variable view of SINUMERIK Operate.
Programming online help
You can use the "SINUMERIK HMI programming package sl" for additional options for
configuring the online help. Using this programming package, it is possible to develop high-level
language applications in the C++ programming language for SINUMERIK Operate on the NCU
7x0.
Note
The "SINUMERIK HMI programming package sl" must be ordered separately as a software option.
The associated documentation is provided together with the programming package.
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
77
Dialogs
5.3 Configuring the online help
5.3.2
Generating HTML files
Generating help files in the HTML format. It is possible to save all information in a single HTML
file or to distribute the information over several HTML files.
You can assign the file names yourself, however, you must observe the following:
• References within HTML files should always be specified with relative paths. Only then can it
be ensured that the references function in precisely the same way on both the development
computer as well as on the target system.
• If jumps are to be made to certain points within an HTML file per link, then so-called anchors
must be defined for this purpose.
Example of an HTML anchor:
<a name="myAnchor">This is an anchor</a>
• The contents of HTML documents must be saved with the UTF-8 coding. Only then is it
guaranteed that the HTML documents are correctly displayed in all of the country languages
supported by SINUMERIK Operate.
• The following sub-sets of the HTML functional scope are supported:
HTML tags
Tag
Description
Comment
a
Anchor or link
Supported attributes: href and name
address
Address
big
Larger font
block quote
Indented paragraph
body
Document body
Supported attributes: bgcolor (#RRGGBB)
br
Line break
center
Centered paragraph
cite
Inline citation
Same effect as tag i
code
Code
Same effect as tag tt
dd
Definition data
dfn
Definition
Same effect as tag i
div
Document division
The standard block attributes are supported
dl
Definition list
The standard block attributes are supported
dt
Definition term
The standard block attributes are supported
em
Emphasized
Same effect as tag i
font
Font size, family, color
Supported attributes: size, face, and color (#RRGGBB)
h1
Level 1 heading
The standard block attributes are supported
h2
Level 2 heading
The standard block attributes are supported
h3
Level 3 heading
The standard block attributes are supported
h4
Level 4 heading
The standard block attributes are supported
h5
Level 5 heading
The standard block attributes are supported
h6
Level 6 heading
The standard block attributes are supported
head
Document header
SINUMERIK Integrate Run MyScreens
78
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.3 Configuring the online help
Tag
Description
Comment
hr
Horizontal line
Supported attributes: width (can be specified as absolute or
relative value)
html
HTML document
i
Italic
img
Image
Supported attributes: src, width, height
kbd
User-entered text
meta
Meta information
li
List item
nobr
Non-breakable text
ol
Ordered list
The standard attributes for lists are supported
p
Paragraph
The standard block attributes are supported (default setting:
left-aligned)
pre
Preformatted text
s
Strikethrough
samp
Sample code
Same effect as tag tt
small
Small font
span
Grouped elements
strong
Strong
Continuous text is heavily emphasized, replaces tag b
sub
Subscript
sup
Superscript
table
Table
Supported attributes: border, bgcolor (#RRGGBB), cellspac-
ing, cellpadding, width (absolute or relative), height
tbody
Table body
No effect
td
Table data cell
The standard attributes for table cells are supported
tfoot
Table footer
No effect
th
Table header cell
The standard attributes for table cells are supported
thead
Table header
This is used to print tables that extend over several pages
title
Document title
tr
Table row
Supported attributes: bgcolor (#RRGGBB)
tt
Typewrite font
u
Underlined
ul
Unordered list
The standard attributes for lists are supported
var
Variable
Same effect as tag tt
Block attributes
The following attributes are supported by the tags div, dl, dt, h1, h2, h3, h4, h5, h6, p:
• align (left, right, center, justify)
• dir (ltr, rtl)
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
79
Dialogs
5.3 Configuring the online help
Standard attributes for lists
The following attributes are supported by tags ol and ul:
• type (1, a, A, square, disc, circle)
Standard attributes for tables
The following attributes are supported by tags td and th:
• width (absolute, relative, no-value)
• bgcolor (#RRGGBB)
• colspan
• rowspan
• align (left, right, center, justify)
• valign (top, middle, bottom)
CSS properties
The following table includes the supported CSS functional scope:
Property
Values
Description
backg34round color
<color>
Background color for elements
backg34round-image
<uri>
Background image for elements
color
<color>
Foreground color for text
text-indent
<length>px
Indent the first line of a paragraph in pixels
white-space
normal | pre | nowrap | pre-
Defines how whitespace characters are handled
wrap
in HTML documents
margin-top
<length>px
Width of the upper edge of the paragraph in pixels
margin-bottom
<length>px
Width of the lower edge of the paragraph in pixels
margin-left
<length>px
Length of the left hand edge of the paragraph in
pixels
margin-right
<length>px
Width of the right-hand edge of the paragraph in
pixels
vertical-align
baseline | sub | super | middle
Vertical alignment for text (in tables, only the val-
| top | bottom
ues middle, top and bottom are supported)
border-color
<color>
Border color for text tables
border-style
none | dotted | dashed | dot-
Border style for text tables
dash | dot-dot-dash | solid |
double | groove | ridge | inset
| outset
backg34round
[ <'backg34round-color'> ||
Short notation for backg34round property
<'backg34round-image'> ]
page-break-before
[ auto | always ]
Page break before a paragraph/table
page-break-after
[ auto | always ]
Page break after a paragraph/table
backg34round-image
<uri>
Background image for elements
SINUMERIK Integrate Run MyScreens
80
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.3 Configuring the online help
Supported CSS selectors
All of the CSS 2.1 selector classes are supported, with the exception of so-called pseudo-selector
classes, such as :first-child, :visited and :hover.
5.3.3
Generating the help book
The help book is an XML file in which the structure of the online help is defined. In this file, you
define:
• HTML documents
• Contents and subject index
Syntax for the help book
Tag
Number
Meaning
HMI_SL_HELP
1
Root element of the XML document
I-BOOK
Identifies a help book. The name can be freely selected under the con-
I
straint that no name predefined by the system is used (such as sinu-
I
merik_alarm_plc_pmc).
I
In the example, the name of the help book is "hmi_myhelp"
I
Attributes:
I
+
I
ref
Identifies the HTML document that is displayed as the entry
I
page for the help book.
I
title
Title of the help book that is displayed in the table of con-
I
tents.
helpdir
Directory that contains the online help of the help book.
I-ENTRY
Section of the online help
II
Attributes:
II
ref
Identifies the HTML document that is displayed as entry
II
page for the section.
II
*
II
title
Title of the section that is displayed in the table of contents.
II
II
II-INDEX_ENTRY
Subject (keyword) to be displayed
II
Attributes:
II
ref
Identifies the HTML document that is jumped to for this
II
subject index entry.
II
*
II
title
Title of the subject that is displayed in the subject index.
II
II
The following applies for the "Number" column:
* means 0 or more
+ means 1 or more
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
81
Dialogs
5.3 Configuring the online help
Example for a help book
In the following example, the structure of a help book with the "My Help" name is described.
Further, it forms the basis for the table of contents and subject index.
<?xml version="1.0" encoding="utf-8"?>
<HMI_SL_HELP language="en-US">
<BOOK ref="index.html" title="My Help" helpdir="hmi_myhelp">
<ENTRY ref="section_1.html" title="Section 1">
<INDEX_ENTRY ref="section_1html#Keyword_1" title="Keyword_1"/>
<INDEX_ENTRY ref="section_1.html#Keyword_2" title="Keyword_2"/>
</ENTRY>
<ENTRY ref="section_2.html" title="Section 2">
<INDEX_ENTRY ref="section_2.html#Keyword_3" title="Keyword_3"/>
</ENTRY>
<ENTRY ref="section_3.html" title="Section 3">
<ENTRY ref="section_31.html" title="Section 31">
INDEX_ENTRY ref="section_31.html#test" title="test;section31"/>
</ENTRY>
<ENTRY ref="section_32.html" title="Section 32">
INDEX_ENTRY ref="section_32.html#test" title="test;section32"/>
</ENTRY>
</ENTRY>
</BOOK>
</HMI_SL_HELP>
The book comprises three sections, whereby the third section has two subsections. The various
subject words (keywords) are defined within the section.
SINUMERIK Integrate Run MyScreens
82
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.3 Configuring the online help
You have the following three options to format the subject index:
1. Single entry:
<INDEX_ENTRY ...title="index"/>
2. Two two-stage entry, whereby each title has a main and a subentry. Separate the entries from
one another using a comma.
<INDEX_ENTRY ...title="mainIndex_1,subIndex_1 with mainIndex_1"/>
3. Two-stage entry, whereby the first title is the main entry and the second title is the subentry.
Separate the entries from one another using a semicolon.
<INDEX_ENTRY ...title="mainIndex_2;subIndex_2 without
mainIndex_1"/>
5.3.4
Integrating the online help in SINUMERIK Operate
If you wish to integrate the generated help book into the online help system of
SINUMERIK Operate, then you require the "slhlp.xml" file.
Format description of the "slhlp.xml"
Tag
Num-
Meaning
ber
CONFIGURATION
1
Root element of the XML document. Designates that this in-
volves a configuration file.
I-OnlineHelpFiles
1
Introduces the section about the online help books.
II-<help_book>
*
Introduces the section of a help book.
III-EntriesFile
File name of the help book with the list of contents and subject
III
(keyword) entries.
III
Attributes:
1
III
value
Name of the XML file
III
type
Data type of the value (QString)
III
III-Technology
Specifies the technology that applies to the help book.
III
"All" applies to all technologies.
III
If the help book applies to several technologies, then the tech-
III
nologies are listed separated by comma.
III
0, 1
Possible values:
III
All, Universal, Milling, Turning, Grinding, Stroking, Punching
III
III
Attributes:
III
value
Technology data
III
type
Data type of the value (QString)
IIII
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
83
Dialogs
5.3 Configuring the online help
Tag
Num-
Meaning
ber
III -DisableSearch
Disable the subject (keyword) search for the help book.
III
Attributes:
III
0, 1
value
true, false
III
III
type
type, data type of the value (bool)
III
III-DisableFullTextSearch
Disable the full text search for the help book.
III
Attributes:
III
0, 1
value
true, false
III
type
type, data type of the value (bool)
III
III-DisableIndex
Disable the subject index for the help book.
III
Attributes:
III
0, 1
value
true, false
III
III
type
type, data type of the value (bool)
III-DisableContent
Disable the table of contents for the help book.
III
Attributes:
0, 1
III
value
true, false
III
type
type, data type of the value (bool)
III
III-DefaultLanguage
Abbreviation for the language that should be displayed if the
III
actual country language is available for the help book.
III
Attributes:
0, 1
III
value
chs, deu, eng, esp, fra, ita, ...
III
type
Data type of the value (QString)
III
The following applies for the "Number" column:
* means 0 or more
Example of a file "slhlp.xml"
The help book "hmi_myhelp.xml" is made known to SINUMERIK Operate in the following
example.
The subject index has not been activated for the help book.
<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<!DOCTYPE CONFIGURATION>
<CONFIGURATION>
<OnlineHelpFiles>
<hmi_myHelp>
<EntriesFile value="hmi_myhelp.xml" type="QString"/>
<DisableIndex value="frue" type="bool"/>
</hmi_myHelp>
</OnlineHelpFiles>
</CONFIGURATION>
SINUMERIK Integrate Run MyScreens
84
Programming Manual, 10/2020, A5E40869575B AD
Dialogs
5.3 Configuring the online help
5.3.5
Saving help files
Saving help files in the target system
1. Open the /oem/sinumerik/hmi/hlp directory and create a new folder for the required
language. For this purpose, use the specified language code.
It is mandatory that the folder names are written in lower-case letters.
For instance, if you are integrating a help function for German and English, then create the
"deu" and "eng" folders.
2. Place the help book, e.g. "hmi_myhelp.xml" in the "deu" and "eng" folders.
3. Copy the help files into the directories, e.g. /oem/sinumerik/hmi/hlp/deu/hmi_myhelp for
German and /oem/sinumerik/hmi/hlp/eng/hmi_myhelp for English help files.
4. Place the configuration file "slhlp.xml" into the directory /oem/sinumerik/hmi/cfg.
5. Restart the HMI.
Note
When displaying the list of contents and subject index of a help book, the help files are saved
in the binary format (slhlp_<Hilfe-Buch_*.hmi) under the directory /siemens/sinumerik/
sys_cache/hmi/hlp for faster use. If you change the help book, you must always delete these
files.
5.3.6
Help files in PDF format
In addition to help files in HTML format, you can also include PDF-format information in the
operating software. Individual PDF helps can be opened with links from the table of contents or
index, or directly from HTML files.
Storing PDF helps
Copy the PDF helps to one of the following directories:
/oem/sinumerik/hmi/hlp/<lng>/<hmi_myhelp>
/user/sinumerik/hmi/hlp/<lng>/<hmi_myhelp>
Including PDF helps
Bind in dialog configurations or configurations of table of contents and indexes with the
extension "pdf" in the same manner as for the "html" extension:
<ENTRY ref="myFile.pdf" title="Help 1">
Create a link from HTML files to the PDF help:
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
85
Dialogs
5.3 Configuring the online help
<a href="myFile.pdf">My Help File</a>
Note
It is not possible to select context-sensitive jump labels in the PDF help, select jump labels or
make jumps to other HTML or PDF files.
The search function is possible only within a PDF file. A higher-level search over multiple PDF
helps is not supported.
SINUMERIK Integrate Run MyScreens
86
Programming Manual, 10/2020, A5E40869575B AD
Variables
6
6.1
Defining variables
Variable value
The major property of a variable is its value.
The value of variables can be assigned by means of:
• Default settings when defining variables
• Assignment to a system or user variable
• A method
Programming
Syntax:
Identifier.val = Variable value
Identifier = Variable value
Description:
Variable value val (value)
Parameter:
Identifier:
Name of the variable
Variable value:
Value of the variable
Example:
VAR3 = VAR4 + SIN(VAR5)
VAR3.VAL = VAR4 + SIN(VAR5)
Variable status
The "Variable status" property scans a variable for valid content during runtime. This property
can be read and written with the value FALSE = 0.
Programming
Syntax:
Identifier.vld
Description:
Variable status vld (validation)
Parameter:
Identifier:
Name of the variable
The result of the scan can be:
FALSE =
invalid value
TRUE =
valid value
Example:
IF VAR1.VLD == FALSE
VAR1 = 84
ENDIF
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
87
Variables
6.2 Application examples
6.2
Application examples
Help variables
Help variables are internal arithmetic variables. Arithmetic variables are defined like other
variables, but have no other properties apart from variable value and status, i.e. help variables
are not visible in the dialog. Help variables are of the VARIANT type.
Programming
Syntax:
DEF [identifier]
Description:
Internal arithmetic variables of the VARIANT type
Parameters:
Identifier:
Name of the help variable
Example:
DEF OTTO ;Definition of a help variable
Syntax:
Identifier.val = Help variable value
Identifier = Help variable value
Description:
A value is assigned to a help variable in a method.
Parameters:
Identifier:
Name of the help variable
Help variable value:
Content of the help variables
Example:
LOAD
OTTO = "Test"
; Assign the value "Test" to the help variable Otto
END_LOAD
LOAD
OTTO = REG[9].VAL
; Assign the value of the register to the help variable
Otto
END_LOAD
Calculation with variables
Variables are calculated every time you exit an I/O field (by pressing the ENTER or toggle key). The
calculation is configured in a CHANGE method that is processed every time the value changes.
Whether a variable has a valid value can be queried via the variable status, e.g.:
IF VAR1.VLD == FALSE
VAR1 = 84
ENDIF
SINUMERIK Integrate Run MyScreens
88
Programming Manual, 10/2020, A5E40869575B AD
Variables
6.2 Application examples
Addressing system variables indirectly
A system variable can also be addressed indirectly, i.e. as a function of another variable:
PRESS(HS1)
ACHSE=ACHSE+1
WEG.VAR="$AA_DTBW["<<ACHSE<<"]"
;Address axis address via variable
END_PRESS
Changing a softkey label
Example:
HS3.st = "New text"
;Change softkey label
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
89
Variables
6.3 Example 1: Assigning the variable type, texts, help display, colors, tooltips
6.3
Example 1: Assigning the variable type, texts, help display, colors,
tooltips
Example 1a
The following example defines a variable for which the properties variable type, texts, help
display and colors are set.
DEF Var1 = (R///,"Actual value",,"mm"//"Var1.png"////8,2)
Variable type:
REAL
Texts:
Short text:
Actual value
Unit text:
mm
Help screen:
Var1.png
Colors:
Foreground color:
8 (brown)
Background color:
2 (orange)
Example 1b
The following example defines a variable for which the properties variable type, default setting,
texts, tooltip, input mode and position of short text are set.
DEF Var2 = (I//5/"","Value","",""," Tooltip text"/wr2///20,250,50)
Variable type:
INTEGER
Default setting:
5
Texts:
Short text:
Value (possible language text ID)
Tooltip:
ToolTipText
Attributes:
Input mode:
Reading and writing
Position of short text:
Distance from left:
20
Distance from top:
250
Width:
50
See also
Variable parameters (Page 98)
SINUMERIK Integrate Run MyScreens
90
Programming Manual, 10/2020, A5E40869575B AD
Variables
6.4 Example 2: Assigning the Variable Type, Limits, Attributes, Short Text Position properties
6.4
Example 2: Assigning the Variable Type, Limits, Attributes, Short
Text Position properties
Example 2
The following example defines a variable for which the properties variable type, limits, input
mode, alignment and position are set.
DEF Var2 = (I/0,10///wr1,al1///,,300)
Variable type:
INTEGER
Limits or toggle field entries:
MIN: 0
MAX: 10
Attributes:
Input mode:
Read-only
Alignment of short text:
Right-justified
Position of short text:
Width:
300
See also
Variable parameters (Page 98)
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
91
Variables
6.5 Example 3: Assigning the Variable Type, Default, System or User Variable, Input/Output Field Position properties
6.5
Example 3: Assigning the Variable Type, Default, System or User
Variable, Input/Output Field Position properties
Example 3
The following example defines a variable for which the properties variable type, default setting,
system or user variable and position are set.
DEF Var3 = (R//10////"$R[1]"//300,10,200//)
Variable type:
REAL
Default setting:
10
System or user variable:
$R[1] (R-Parameter 1)
Position of short text:
Default position in relation to input/output field
Position of input/output field:
Distance from left:
300
Distance from top:
10
Width:
200
See also
Variable parameters (Page 98)
SINUMERIK Integrate Run MyScreens
92
Programming Manual, 10/2020, A5E40869575B AD
Variables
6.6 Example 4: Toggle field and list field
6.6
Example 4: Toggle field and list field
Example 4a
Various entries in the toggle field:
DEF Var1 = (I/* 0,1,2,3)
;Simple toggle field to toggle numeric values
DEF Var2 = (S/* "On", "Off")
;Simple toggle field to toggle strings
DEF Var3 = (B/* 1="On", 0="Off")
;Extended toggle field to toggle numeric values whereby a
display text is assigned to each numeric value
DEF Var4 = (R/* ARR1)
;Toggle field, which obtains its values to be toggled from an
array
Example 4b
The list field corresponds to the configuration of a toggle field, but the display type for the list
field (variable attribute DT = 4) must also be set.
DEF VAR_LISTBOX_Text = (S/*$80000,$80001,$80002,$80003,$80004/$80001//DT4////200,,340,60)
Variable type:
STRING
Limits / toggle field:
*$80000,$80001,$80002,$80003,$80004
(list of the language-dependent texts to be dis-
played)
Default setting:
$80001
Attributes:
Display type:
4 (list field)
Position of input/output field:
Distance from left:
200
Width:
340
Height:
60
Colors:
Foreground color:
6 (blue)
Background color:
10 (white)
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
93
Variables
6.7 Example 5: Image display
6.7
Example 5: Image display
Example 5
Displaying an image instead of a short text: The size and position of the image is defined under
"Position of input/output field (left, top, width, height)".
DEF VAR6= (V///,"\\image1.png" ////160,40,50,50)
Variable type:
VARIANT
Texts:
Short text:
image1.png
Position of input/output field:
Distance from left:
160
Distance from the top:
40
Width:
50
Height:
50
SINUMERIK Integrate Run MyScreens
94
Programming Manual, 10/2020, A5E40869575B AD
Variables
6.8 Example 6: Progress bar
6.8
Example 6: Progress bar
The progress bar is a special display type of the input/output field and is designed for display
without input.
Basically there are two progress bar types:
1. Progress bars with up to two color changes, e.g. for temperature or utilization display (see
example 6a)
2. Progress bars to display progress (no color change) in the Operate style (see example 6b)
Example 6a
Progress bar with two color changes:
Figure 6-1
Progress bar with two color changes
DEF PROGGY0 = (R/0,150,50,100///DT1,DO0//"$R[10]"//,,150/3,4,,,,,,,9,7)
Variable type:
REAL
Limits / toggle field:
MIN:
0
MAX:
150
Signal value SVAL1:
50
Signal value SVAL2:
100
Attributes:
Display mode DT:
1 (progress bar)
Display option DO:
0 (from left to right (default))
System or user variable:
$R[10]
Position of input/output field:
Width:
150
Colors:
Foreground color:
3 (dark green)
Background color:
4 (light gray)
Signal color SC1:
9 (yellow)
Signal color SC2:
7 (red)
To use a progress bar with color change, the display mode DT (DisplayType) must be set to 1.
The orientation of the progress bar is determined via the attribute display option DO
(DisplayOption):
0: From left to right (default)
1: From right to left
2: From bottom to top
3: From top to bottom
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
95
Variables
6.8 Example 6: Progress bar
A MIN and a MAX value must be specified for the display of the progress bar (in the example MIN:
0, MAX: 150).
Depending on the current value of the variable PROGGY0, this setting already displays a progress
bar with the foreground color 3 (= dark green) and the backg34round color 4 (= light gray).
Optionally, one or two signal values SVAL1 and SVAL2 (limit parameters) can be defined (in the
example SVAL1: 50 and SVAL2: 100). With these signal values, the foreground color of the
progress bar changes. The appropriate signal colors are specified via parameters SC1 and SC2 (in
the above example SC1: 9 (= yellow) and SC2: 7 (=red)).
The following rule applies when specifying limit values for the progress display:
MIN < SVAL1 < SVAL2 < MAX.
Example 6b
Progress bar without color change:
Figure 6-2
Progress bar
DEF PROGGY0 = (R/0,150///DT2,DO0//"$R[10]"//,,150/6,10)
Variable type:
REAL
Limits / toggle field:
MIN:
0
MAX:
150
Attributes:
Display type DT:
2 (progress bar)
Display option DO:
0 (from left to right (default))
System or user variable:
$R[10]
Position of input/output field:
Width:
150
Colors:
Foreground color:
6 (blue)
Background color:
10 (white)
To use a progress bar without color change, the display mode DT (DisplayType) must be set to 2.
The orientation of the progress bar is determined via the attribute display option DO
(DisplayOption) (see description for example 6a).
A MIN and a MAX value must be specified for the display of the progress bar (in the example MIN:
0, MAX: 150).
Depending on the current value of the variable PROGGY0, this setting displays a progress bar
with the foreground color 6 (= blue) and the backg34round color 10 (= white).
SINUMERIK Integrate Run MyScreens
96
Programming Manual, 10/2020, A5E40869575B AD
Variables
6.9 Example 7: Password input mode (asterisk)
6.9
Example 7: Password input mode (asterisk)
Example 7
To implement a field with hidden input, e.g. to enter a password, then display mode DT must be
set to 5. Asterisks are then displayed instead of the entered characters.
Figure 6-3
Password input mode (asterisk)
DEF VAR_SET_PWD=(S//""//DT5)
Variable type:
STRING
Default setting:
Empty string
Attributes:
Display mode DT:
5 (password input mode)
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
97
Variables
6.10 Variable parameters
6.10
Variable parameters
Parameters - overview
The following overview provides a brief explanation of the variable parameters. Subsequent
chapters contain a more detailed description.
Parameter
Description
Variable type (Page 104)
The variable type must be specified.
R[x]:
REAL (+ digit for the decimal place)
I:
INTEGER
S[x]:
STRING (+ digit for string length)
C:
CHARACTER (individual character)
B:
BOOL
V:
VARIANT
Limits (Page 91)
Limit value MIN, limit value MAX
Default setting: Empty
The limit values are separated by a comma. Limits can be specified for types I, C and R in
decimal formats or as characters in the form "A", "F".
Optionally, two signal colors SC1 and SC2 can be configured for the display of a progress bar
with color change (variable attribute DT = 1) which are displayed as the respective fore-
ground color of the bar when the signal value SVAL1 or SVAL2 is exceeded. The signal values
are specified as integer values.
See application example for Progress bar (Page 95).
Pre-assignment (Page 109)
If no default setting has been configured and no system or user variable has been assigned
to the variable, the first element of the toggle field is assigned. If no toggle field has been
defined, there is no default setting, which means the status of the variable is "not calcula-
ted".
Default setting: No default
Toggle field (Page 107)
List with predetermined entries in the IO field: The list is initiated by a *; the entries are
separated by a comma. The entries can be assigned a value.
For the toggle field, the entry for the limit is interpreted as a list. If only one * is entered, a
variable toggle field is created.
Default setting: None
Texts (Page 90)
The sequence is specified. Instead of a short text, an image can also be displayed.
Default setting: Empty
Long text:
Text in the display line
Short text:
Name of the dialog element
Graphic text:
Text refers to the terms in the graphics
Unit text:
Unit of the dialog element
Tooltip
Serves as brief information in a screen configuration for the
display and toggle fields. The information is configured via plain
text and language text ID.
SINUMERIK Integrate Run MyScreens
98
Programming Manual, 10/2020, A5E40869575B AD
Variables
6.10 Variable parameters
Parameter
Description
Attributes (Page 91)
The attributes influence the following properties:
• Display mode
• Display option
• Update rate
• Toggle symbol
• Tooltip
• Input mode
• Access level
• Alignment of short text
• Font size
• Limits
The attributes are separated by commas and appear in any order. A definition can be made
for each component.
Display mode
dt0: Standard (input/output field or toggle field) (default)
dt1: Progress bar with color change
dt2: Progress bar without color change in the Operate style
dt4: List field
dt5: Password input mode (asterisk)
Display option
Particularly, e.g. for the display modes dt1 and dt2 (progress bars), a
display option may also have to be configured in combination.
do0: From left to right (default)
do1: From right to left
do2: From bottom to top
do3: From top to bottom
Update rate
The attribute UR (update rate) controls the update of the display and
therefore the processing of the associated, configured CHANGE block of
variables or grid columns. Depending on the configuration, the CPU
load can be drastically reduced and therefore shorter response times
achieved on the user interface.
ur0: SlCap::standardUpdateRate() (currently = 200 ms, default value)
ur1: 50 ms
ur2: 100 ms
ur3: 200 ms
ur4: 500 ms
ur5: 1000 ms
ur6: 2000 ms
ur7: 5000 ms
ur8: 10000 ms
Toggle symbol
tg0: Toggle symbol off (default)
tg1: Toggle symbol on
If the attribute TG is set to 1, the toggle symbol also appears in the
tooltip of the input field.
Example:
DEF OFFS = (R//123.456/,,,,"My ToolTip"/TG1)
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
99
Variables
6.10 Variable parameters
Parameter
Description
Tooltip
The tooltip text can also be changed during runtime via the variable
property "TT".
Example:
PRESS(VS1)
MyVar.TT = "My new ToolTip"
END_PRESS
or
DEF MyVar=(R///,,,,"My ToolTip-text")
Input mode
wr0: IO field invisible, short text visible
wr1: Read (no focus possible for input)
wr2: Read and write (line appears in white)
wr3: wr1 with focus
wr4: All variable elements invisible, no focus possible
wr5: The value entered is saved immediately on every keystroke (in
contrast to wr2, where it is only saved when the field is exited or RETURN
is pressed).
Default setting: wr2
Access level
Empty: Can always be written
ac0...ac7: Protection levels
If the access level is not adequate, then the first line is displayed in gray,
default setting: ac7
Alignment of
al0: Left-justified
short text
al1: Right-justified
al2: Centered
Default setting: al0
Font size
fs1: Default font size (8 pt.)
fs2: Double font size
Default setting: fs1
The clearances between the lines is defined. With the default font size,
16 lines will fit into the dialog. Graphics and unit text can only be con-
figured in the default font size.
Limits
Consequently, it is possible to check whether the values of the variable
are within the MIN and MAX limits specified.
Default setting: Determined by specified limits
li0: No check
li1: Check with respect to min.
li2: Check with respect to max.
li3: Check with respect to min. and max.
Behavior when
cb attributes specified for a variable in a variables definition take priority
opening
over the cb default setting in the dialog definition. Multiple attributes
are separated by commas (see also AUTOHOTSPOT).
Calling the
CB0: The CHANGE method is triggered when the screen is displayed if
CHANGE method
the variable has a valid value at this time (e.g. through default setting
or NC/PLC variable).
SINUMERIK Integrate Run MyScreens
100
Programming Manual, 10/2020, A5E40869575B AD
Variables
6.10 Variable parameters
Parameter
Description
CB1: The CHANGE method is not explicitly triggered when the screen is
displayed. If the variable has a configured NC/PLC variable, then the
CHANGE method is of course still called.
Empty Input (EI)
The variable attribute "EI" (= Empty Input) can be used to specify how
the input field is to respond if an empty string is entered.
EI0: Standard, i.e. empty inputs into the input field are accepted.
EI1: Empty inputs lead to an error status for the input field, and the
previous value is set again (Undo).
Help display (Page 90)
Help display file:
Name of the png file
Default setting: Empty
The name of the Help display file appears in double quotation marks. The display appears
automatically (instead of the previous graphic) if the cursor is positioned on this variable.
System or user variable
System or user data from the NC/PLC can be assigned to the variable. The system or user
(Page 92)
variable appears in double quotation marks.
Reference: List Manual System Variables, /PGAsl/
Position of short text (Page 110)
Position of short text (distance from left, distance from top, width)
The positions are entered in pixels and relate to the upper left-hand corner of the main body
of the dialog. The entries are separated by commas.
Position of input/output field
Position of input/output field (distance from left, distance from top, width, height)
(Page 110)
The positions are entered in pixels and relate to the upper left-hand corner of the main body
of the dialog. The entries are separated by commas. If this position changes, the positions
of the short text, graphic text and unit text also change.
Colors (Page 90)
Foreground and backg34round colors for input/output fields, short texts, graphic texts, unit
texts and signal colors for progress bars:
The colors are separated by a comma.
For specification of the color, see Chapter AUTOHOTSPOT.
Default setting for input/output field: Foreground color: Black, backg34round color: White
The default colors of the input/output field depend on the "wr" write mode:
Default setting for short text, graphic text, unit text: Foreground color: Black, backg34round
color: Transparent.
Optionally, two signal colors SC1 and SC2 can be configured for the display of a progress bar
with color change (variable attribute DT = 1) which are displayed as the respective fore-
ground color of the bar when the signal value SVAL1 or SVAL2 is exceeded.
See application example for Progress bar (Page 95).
The colors are expected in the following order in the variables definition:
1. Foreground color of the input/output field: FC
2. Background color of the input/output field: BC
3. Foreground color of the short text: FC_ST
4. Background color of the short text: BC_ST
5. Foreground color of the graphic text: FC_GT
6. Background color of the graphic text: BC_GT
7. Foreground color of the unit text: FC_UT
8. Background color of the unit text: BC_UT
9. Signal color 1
10. Signal color 2
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
101
Variables
6.10 Variable parameters
Parameter
Description
Online help file
The name of the online help file appears in double quotation marks.
I/O field with integrated unit se-
You can use the input/output fields with integrated unit selection to toggle between dif-
lection
ferent units. If the cursor is moved to the input field, the integrated unit selection is high-
lighted (focus does not have to be explicitly placed on it). A tooltip with a toggle symbol is
also displayed with the appropriate reference to this functionality.
Examples:
DEF VarEdit=(R////////200,,100///"VarTgl")
VarTgl=(S/*0="mm",1="inch"/0//WR2////302,,40)
or
DEF VarEdit_2={TYP="R", VAL=1.234, X=200, W=100,
LINK_TGL="vartgl_2"},
VARTgl_2={TYP="S", TGL="* 0=""mm"", 1=""inch""",WR=2, X=302,
W=40}
Variable: Changing properties
A new value is assigned to the variables in the notation Identifier.Property = Value when
changing. The expression to the right of the equality sign is evaluated and assigned to the
variable or variable property.
Identifier.ac = Access level
(ac: access level)
Identifier.al = Text alignment
(al: alignment)
Identifier.bc = Background color of the input/output field
(bc: back color)
Identifier.bc_gt = Background color of the graphic text
(bc: back color)
(gt: graphic text)
Identifier.bc_st = Background color of the short text
(bc: back color)
(st: short text)
Identifier.bc_ut = Background color of the unit text
(bc: back color)
(ut: unit text)
Identifier.do = Display option
(do: display option)
Identifier.dt = Display mode
(dt: display type)
Identifier.fc = Foreground color of the input/output field
(fc: front color)
Identifier.fc_gt = Foreground color of the graphic text
(fc: front color)
(gt: graphic text)
Identifier.fc_st = Foreground color of the short text
(fc: front color)
(st: short text)
Identifier.fc_ut = Foreground color of the unit text
(fc: front color)
(ut: unit text)
Identifier.fs = Font size
(fs: font size)
Identifier.gt = Graphic text
(gt: graphic text)
Identifier.hlp = Help display
(hlp: help)
Identifier.li = Limit
(li: limit)
Identifier.lt = Long text
(lt: long text)
Identifier.max = MAX limits
(max: maximum)
Identifier.min = MIN limits
(min: minimum)
SINUMERIK Integrate Run MyScreens
102
Programming Manual, 10/2020, A5E40869575B AD
Variables
6.10 Variable parameters
Identifier.sc = Signal color
(sc: signal color)
Identifier.st = Short text
(st: short text)
Identifier.tg = Toggle symbol
(tg: toggle)
Identifier.tt = Tooltip
(tt: tooltip
Identifier.typ = Variable type
(typ: type)
Identifier.ur = Update rate
(ur: update rate)
Identifier.ut = Unit text
(ut: unit text)
Identifier.val = Variable value
(val: value)
Identifier.var = System or user variable
(var: variable)
Identifier.vld = Variable status
(vld: validation)
Identifier.wr = Input mode
(wr: write)
See also
Extended configuration syntax (Page 49)
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
103
Variables
6.11 Details on the variable type
6.11
Details on the variable type
Variable type INTEGER
The following extensions for determining the display in the input/output field and the memory
utilization are possible for the "INTEGER" type:
2nd character in the extension data type
Representation format
B
Binary
D
Decimal signed
H
Hexadecimal
Not specified
Decimal signed
3rd and/or 4th character in the extension data type
Memory utilization
B
Byte
W
Word
D
Doubleword
BU
Byte, unsigned
WU
Word, unsigned
DU
Double word, unsigned
Sequence of characters for the INTEGER data type
1. "I" Basic INTEGER designation
2. Representation format
3. Memory utilization
4. "U" Unsigned
Valid INTEGER type specifications:
IB
Integer variable 32 bits in binary notation
IBD
Integer variable 32 bits in binary notation
IBW
Integer variable 16 bits in binary notation
IBB
Integer variable 8 bits in binary notation
I
Integer variable 32 bits in decimal notation signed
IDD
Integer variable 32 bits in decimal notation signed
IDW
Integer variable 16 bits in decimal notation signed
IDB
Integer variable 8 bits in decimal notation signed
IDDU
Integer variable 32 bits in decimal notation unsigned
IDWU
Integer variable 16 bits in decimal notation unsigned
IDBU
Integer variable 8 bits in decimal notation unsigned
SINUMERIK Integrate Run MyScreens
104
Programming Manual, 10/2020, A5E40869575B AD
Variables
6.11 Details on the variable type
Valid INTEGER type specifications:
IH
Integer variable 32 bits in hexadecimal notation
IHDU
Integer variable 32 bits in hexadecimal notation
IHWU
Integer variable 16 bits in hexadecimal notation
IHBU
Integer variable 8 bits in hexadecimal notation
Variable type VARIANT
The VARIANT variable type is determined by the data type of the last value assignment. If the
assigned or entered value starts with '-', '+', '.' or a number ('0'-'9'), then the value is interpreted
as numeric. In all other cases as a string.
It can be scanned using the ISNUM or ISSTR function. The VARIANT type is mainly suited to the
purpose of writing either variable names or numerical values to the NC code.
Programming
The data type of variables can be checked:
Syntax:
ISNUM (VAR)
Parameters:
VAR
Name of the variable whose data type is to be checked.
The result of the scan can be:
FALSE =
not a numerical variable (data type = STRING)
TRUE =
numerical variable (data type = REAL)
Syntax:
ISSTR (VAR)
Parameters:
VAR
Name of the variable whose data type is to be
checked.
The result of the scan can be:
FALSE =
numerical variable (data type = REAL)
TRUE =
not a numerical variable (data type = STRING)
Example:
IF ISNUM(VAR1) == TRUE
IF ISSTR(REG[4]+2) == TRUE
The display mode of variables can be changed:
• For INTEGER, the display type can be changed.
B
Binary
D
Decimal signed
H
Hexadecimal
unsigned
With the addition of U for Unsigned
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
105
Variables
6.11 Details on the variable type
• For REAL data types, only the number of places after the decimal point can be changed.
Changing the type is illegal and generates an error message in the "easyscreen_log.txt" file.
Example:
Var1.typ = "IBW"
Var2.typ = "R3"
Number formats
Numbers can be represented in either binary, decimal, hexadecimal or exponential notation:
Binary
B01110110
Decimal
123.45
Hexadecimal
HF1A9
Exponential
-1.23EX-3
Examples:
VAR1 = HF1A9
REG[0]= B01110110
DEF VAR7 = (R//-1.23EX-3)
Note
When codes are generated with the "GC" function, only numerical values in decimal or
exponential notation are evaluated, but not those in binary or hexadecimal notation.
See also
Variable parameters (Page 98)
SINUMERIK Integrate Run MyScreens
106
Programming Manual, 10/2020, A5E40869575B AD
Variables
6.12 Details on the toggle field
6.12
Details on the toggle field
Description
The toggle field extension function displays texts (entries in toggle field) as a function of NC/PLC
variables. A variable, which makes use of a toggle field extension, is read-only. The list of the
toggle field is opened by pressing the ENTER key.
Programming
Syntax:
DEF VAR1=(IB/+ $85000/15////"DB90.DBB5") or
DEF VAR_TGL = (S/* "Hello", "Run", "MyScreens"/"Run")
Description:
When the dialog is opened, the content of text number $85015 is displayed in the IO
field. Default value 15 is entered in system variable DB90.DBB5. If the value saved in
system variable DB90.DBB5 changes, the displayed text number $(85000 +
<DB90.DBB5>) is recalculated in response to every change.
Parameter:
Variable type
Type of variables specified in the system or user variable.
Text number
Number (basis) of the language-specific text valid as the
basis number.
System or user variable
System or user variable (offset) via which the final text
number (basis + offset) is displayed.
Toggle-field-dependent displays
The toggle field is overlaid with graphics, which change depending on the value of the memory
byte. If the value of the memory byte is 1, "image1.png" will appear. If it is 2, "image2.png" will
appear.
DEF VAR1=(IDB/*1="\\image1.png", 2="\\image2.png"//,$85000/wr1//"MB[130]"//160,40,50,50)
The size and position of the image is defined under "Position of IO field (left, top, width, height)".
Virtual toggle key
There is no list for toggle fields without configured list, e.g. DEF NoTglList=(R/*). The next
element is not generated until the toggle key is actuated or the associated CHANGE() method of
the corresponding variable run through.
For this case, a small virtual keyboard (comprising only a toggle key) is displayed on the right
next to the variable toggle field for operation with a touch panel.
The display of the virtual toggle key can also be forced via the following entry in the
configuration file "slguiconfig.ini" irrespective of a touch panel.
[VirtualKeyboard]
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
107
Variables
6.12 Details on the toggle field
; Forces easyscreen virtual toggle keyboard function
ForceEasyscreenVirtualToggleKey = true
See also
Variable parameters (Page 98)
SINUMERIK Integrate Run MyScreens
108
Programming Manual, 10/2020, A5E40869575B AD
Variables
6.13 Details on the default setting
6.13
Details on the default setting
Overview
A variable can assume various states depending on whether a default value, or a system or user
variable, or both, is assigned to the variable field (input/output field or toggle field), (not
calculated: toggling is only possible if a valid value has been assigned to the variable).
Scope of the default settings
Condition
Reaction of field type
Field type
Default setting
System or user variable
I/O field
Yes
Yes
Write default value to system or user variable
No
Yes
Use system or user variable as default value
Fault
Yes
Not calculated, system or user variable is not written/
used.
Yes
No
Default setting
No
No
Not calculated
Fault
No
Not calculated
Yes
Fault
Not calculated
No
Fault
Not calculated
Fault
Fault
Not calculated
Toggle
Yes
Yes
Write default value to system or user variable
No
Yes
Use system or user variable as default value
Fault
Yes
Not calculated,
system or user variable not written/used
Yes
No
Default setting
No
No
Default = first toggle field element
Fault
No
Not calculated
Yes
Fault
Not calculated
No
Fault
Not calculated
Fault
Fault
Not calculated
See also
Variable parameters (Page 98)
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
109
Variables
6.14 Details on the position of the short text, position of the input/output field
6.14
Details on the position of the short text, position of the input/
output field
Overview
The short text and graphic text, as well as the input/output field and unit text, are each treated
like a unit, i.e., position settings for short text apply to the graphic text and data for the input/
output field and to unit text.
Programming
The configured position entry overwrites the default value, i.e., only one value can be changed.
If no position settings have been configured for subsequent screen form elements, then the
position settings for the preceding screen form element are applied.
The default setting is used if positions are not specified for any of the dialog elements. The
column width for the short text and input-output field is calculated as standard for each line from
the number of columns and maximum line width, i.e. column width = maximum line width/
number of columns.
The width of the graphics and unit text is predefined and optimized to suit the requirements of
programming support. If graphics or unit text has been configured, the width of the short text
or I/O field is reduced accordingly.
The order of short text and I/O field can be reversed by position settings.
Distance between the input/output field and unit field and width of the unit field
You can configure the distance between an input/output field and a unit field as well as the width
of the unit field.
In the definition line, in the section for the input/output position, enter the distance from the
input/output field to the unit field, separated by a comma (e.g. 7 pixels) and/or the width of the
unit field (e.g. 60 pixels):
DEF VarDT=(R3//0.000/,"DT",,"s"////0,,24/39,,71,,7,60)
Or:
DEF VarDT={TYP="R3", VAL="0.000", ST="DT", UT="s", TXT_X=0,
TXT_W=24, X=39, W=71, UT_DX=7, UT_W=60}
In this case, the distance between the input/output field/unit field and/or the width of the unit
field have/has been configured and the following points should be taken into account:
• The configured width of the input/output field does not include the fixed width of the unit
field (this is fixed at 50 pixels). This means that you directly configure the width of the input/
output field.
• A 50 pixel width applies as default if a width is not configured for the unit field.
•
0 pixels applies as default if a distance is not configured between the input/output field / unit
field.
SINUMERIK Integrate Run MyScreens
110
Programming Manual, 10/2020, A5E40869575B AD
Variables
6.14 Details on the position of the short text, position of the input/output field
Special feature regarding the associated toggle field
Requirements:
• An associated toggle field is configured for a variable,
• For the variable, a distance is configured between the input/output field and unit field and/or
a width for the unit field, and
• The variable has no unit text.
In this particular case, the associated toggle field is positioned at the configured position of the
unit field of the variable.
A position possibly configured for the input/output component of the associated toggle field is
ignored.
Example
In the following example, the associated toggle field F_Unit is automatically set with a distance
of 7 pixels to the input/output field of variable VarF , and with a width of 59 pixels .
DEF VarF=(R//0.0/,"F",,,////0,,24/39,,85,,7,59///"F_Unit"), F_Unit =
(I/*3="mm/min", 1="mm/U"/3// ////181,,155)
See also
Variable parameters (Page 98)
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2020, A5E40869575B AD
111
Variables
6.15 Use of strings
6.15
Use of strings
Strings
Strings can be used as part of the configuration. These allow text to be displayed dynamically or
different texts to be chained for the purpose of code generation.
Rules
The following rules must be observed with regard to string variables:
• Logic operations are processed from left to right.
• Nested expressions are solved from the inside outwards.
• No distinction is made between uppercase and lowercase type.
• String variables are generally displayed left justified.
Strings can be deleted simply by assigning a blank string.
Strings can be appended after the equality sign using the operator "<<". Quotation marks (") in
the string are represented by two successive quotation mark symbols. Strings can be checked for
equality in IF instructions.
Example
Default settings for the following examples:
VAR1.VAL = "This is an"
VAR8.VAL = 4
VAR14.VAL = 15
VAR2.VAL = "Error"
$85001 = "This is an"
$85002 = "Alarm text"
Editing strings:
• Chaining of strings:
VAR12.VAL = VAR1 << " Error."
;Result: "This is an error"
• Deleting a variable:
VAR10.VAL = ""
;Result: Blank string
• Setting a variable with a text variable:
VAR11.VAL = VAR1.VAL
;Result: "This is an"
• Data type matching:
VAR13.VAL ="This is the " << (VAR14 - VAR8) << ". error"
;Result: "This is the 11th error"
SINUMERIK Integrate Run MyScreens
112
Programming Manual, 10/2020, A5E40869575B AD
|