SINAMICS parameters
3.2 SINAMICS parameters
p7621[0...n]
Header-Ydb SubDO / Head-Ydb SubDO
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: p7620
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p7622
Unit-Ydb SubDO quantity / Unit-Ydb SubDO qty
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
65535
1
p7623[0...n]
Unit-Ydb SubDO / Unit-Ydb SubDO
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: p7622
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p7624
Default-Ydb SubDO quantity / Def-Ydb SubDO qty
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
65535
1
p7625[0...n]
Default-Ydb SubDO / Def-Ydb SubDO
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: p7624
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p7640
Header-Ydb quantity / Head-Ydb qty
All objects
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
65535
1
Machine data and parameters
1658
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p7641[0...n]
Header-Ydb / Head-Ydb
All objects
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned8
Dynamic index: p7640
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p7642
Unit-Ydb quantity / Unit-Ydb quantity
All objects
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
65535
1
p7643[0...n]
Unit-Ydb / Unit-Ydb
All objects
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned8
Dynamic index: p7642
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p7644
Default-Ydb quantity / Def-Ydb qty
All objects
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
65535
1
p7645[0...n]
Default-Ydb / Def-Ydb
All objects
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned8
Dynamic index: p7644
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p7646
Chart-Ydb quantity / Chart-Ydb quantity
All objects
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
65535
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1659
SINAMICS parameters
3.2 SINAMICS parameters
p7647[0...n]
Chart-Ydb / Chart-Ydb
All objects
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned8
Dynamic index: p7646
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
r7699
Ydb backup available / Ydb backup avail
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
1
-
r7740[0...n]
IGBT power cycling counter valve 1 / IGBT load count 1
A_INF, B_INF, S_INF,
Can be changed: -
Calculated: -
Access level: 4
SERVO, SERVO_AC,
Data type: Unsigned16
Dynamic index: PDS, p0120
Function diagram: -
VECTOR, VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7741[0...n]
IGBT power cycling counter valve 2 / IGBT load count 2
A_INF, B_INF, S_INF,
Can be changed: -
Calculated: -
Access level: 4
SERVO, SERVO_AC,
Data type: Unsigned16
Dynamic index: PDS, p0120
Function diagram: -
VECTOR, VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7742[0...n]
IGBT power cycling counter valve 3 / IGBT load count 3
A_INF, B_INF, S_INF,
Can be changed: -
Calculated: -
Access level: 4
SERVO, SERVO_AC,
Data type: Unsigned16
Dynamic index: PDS, p0120
Function diagram: -
VECTOR, VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7743[0...n]
IGBT power cycling counter valve 4 / IGBT load count 4
A_INF, B_INF, S_INF,
Can be changed: -
Calculated: -
Access level: 4
SERVO, SERVO_AC,
Data type: Unsigned16
Dynamic index: PDS, p0120
Function diagram: -
VECTOR, VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1660
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r7744[0...n]
IGBT power cycling counter valve 5 / IGBT load count 5
A_INF, B_INF, S_INF,
Can be changed: -
Calculated: -
Access level: 4
SERVO, SERVO_AC,
Data type: Unsigned16
Dynamic index: PDS, p0120
Function diagram: -
VECTOR, VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7745[0...n]
IGBT power cycling counter valve 6 / IGBT load count 6
A_INF, B_INF, S_INF,
Can be changed: -
Calculated: -
Access level: 4
SERVO, SERVO_AC,
Data type: Unsigned16
Dynamic index: PDS, p0120
Function diagram: -
VECTOR, VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7746
IGBT load counter dynamic / IGBT load dyn
A_INF, B_INF, S_INF,
Can be changed: -
Calculated: -
Access level: 3
SERVO, SERVO_AC,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR, VECTOR_AC
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r7758[0...19]
KHP Control Unit serial number / KHP CU ser_no
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p7759[0...19]
KHP Control Unit reference serial number / KHP CU ref ser_no
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7760.0...12
CO/BO: Write protection/know-how protection status / Wr_prot/KHP stat
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1661
SINAMICS parameters
3.2 SINAMICS parameters
r7760
Write protection/know-how protection status / Wr_prot/KHP stat
A_INF, B_INF, ENC,
Can be changed: -
Calculated: -
Access level: 3
HLA, HUB, R_INF,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
S_INF, SERVO,
P-Group: -
Unit group: -
Unit selection: -
SERVO_AC, TB30,
TM120, TM15, TM150,
Not for motor type: -
Scaling: -
Expert list: 1
TM15DI_DO, TM17,
Min:
Max:
Factory setting:
TM31, TM41,
-
-
-
TM54F_MA,
TM54F_SL, VECTOR,
VECTOR_AC
p7761
Write protection / Write protection
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p7762
Write protection multi-master fieldbus system access behavior / Fieldbus acc_behav
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p7763
KHP OEM exception list number of indices for p7764 / KHP OEM qty p7764
All objects
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
500
1
p7764[0...n]
KHP OEM exception list / KHP OEM excep list
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: p7763
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
[0] 7766
[1...499] 0
Machine data and parameters
1662
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p7764[0...n]
KHP OEM exception list / KHP OEM excep list
A_INF, B_INF, ENC,
Can be changed: T, U
Calculated: -
Access level: 3
HLA, HUB, R_INF,
Data type: Unsigned16
Dynamic index: p7763
Function diagram: -
S_INF, SERVO,
P-Group: -
Unit group: -
Unit selection: -
SERVO_AC, TB30,
TM120, TM15, TM150,
Not for motor type: -
Scaling: -
Expert list: 1
TM15DI_DO, TM17,
Min:
Max:
Factory setting:
TM31, TM41,
0
65535
0
TM54F_MA,
TM54F_SL, VECTOR,
VECTOR_AC
p7765
KHP configuration / KHP config
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p7766[0...29]
KHP password input / KHP pw input
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
p7767[0...29]
KHP password new / KHP pw new
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
p7768[0...29]
KHP password confirmation / KHP pw confirm
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1663
SINAMICS parameters
3.2 SINAMICS parameters
p7769[0...20]
KHP memory card reference serial number / KHP mem ref ser_no
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p7770
NVRAM action / NVRAM action
A_INF, B_INF, ENC,
Can be changed: T
Calculated: -
Access level: 3
HLA, HUB, R_INF,
Data type: Integer16
Dynamic index: -
Function diagram: -
S_INF, SERVO,
P-Group: -
Unit group: -
Unit selection: -
SERVO_AC, TB30,
TM120, TM15, TM150,
Not for motor type: -
Scaling: -
Expert list: 1
TM15DI_DO, TM17,
Min:
Max:
Factory setting:
TM31, TM41,
0
3
0
TM54F_MA,
TM54F_SL, VECTOR,
VECTOR_AC
p7775
NVRAM data backup/import/delete / NVRAM backup
CU_S_AC_DP,
Can be changed: C1, T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: All groups
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
17
0
p7786[0...n]
Service report / Service report
A_INF, B_INF, S_INF,
Can be changed: T, U
Calculated: -
Access level: 4
SERVO, SERVO_AC,
Data type: Unsigned16
Dynamic index: PDS, p0120
Function diagram: -
VECTOR, VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p7787
Deactivating component status / Comp_stat deact
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
1
1
Machine data and parameters
1664
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p7788
Power unit sign-of-life monitoring tolerance window / PU SoL mon tol
A_INF, B_INF, R_INF,
Can be changed: T, U
Calculated: -
Access level: 4
S_INF, SERVO,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Converter
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
1000
10
p7789
Power unit sign-of-life monitoring fault threshold / PU SoL mon F_thr
A_INF, B_INF, R_INF,
Can be changed: T, U
Calculated: -
Access level: 4
S_INF, SERVO,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Converter
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1000
1
p7790[0...15]
Component trace signal / Comp trace sig
A_INF, R_INF (Parallel),
Can be changed: T, U
Calculated: -
Access level: 4
SERVO, VECTOR
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
11
[0] 2
[1] 3
[2] 4
[3] 7
[4] 8
[5] 9
[6] 5
[7] 0
[8] 6
[9] 1
[10...15] 0
p7790[0...15]
Component trace signal / Comp trace sig
B_INF
Can be changed: T, U
Calculated: -
Access level: 4
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
11
[0] 7
[1] 5
[2...7] 0
[8] 6
[9] 1
[10...15] 0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1665
SINAMICS parameters
3.2 SINAMICS parameters
p7790[0...15]
Component trace signal / Comp trace sig
S_INF
Can be changed: T, U
Calculated: -
Access level: 4
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
11
[0] 2
[1] 3
[2] 4
[3] 7
[4] 8
[5] 9
[6] 10
[7] 11
[8] 6
[9] 1
[10...15] 0
p7791
Component trace trigger / Comp trace trigger
B_INF, R_INF (Parallel),
Can be changed: T, U
Calculated: -
Access level: 4
SERVO
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p7791
Component trace trigger / Comp trace trigger
A_INF, S_INF, VECTOR
Can be changed: T, U
Calculated: -
Access level: 4
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
1
p7792
Upload component trace data / Upload comp trace
A_INF, B_INF, R_INF
Can be changed: T, U
Calculated: -
Access level: 4
(Parallel), S_INF,
Data type: Integer16
Dynamic index: -
Function diagram: -
SERVO, VECTOR
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p7800[0...2]
EEPROM logical address for reading and writing / Logical addr
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
Machine data and parameters
1666
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r7801[0...254]
EEPROM read value for logical access / Read value
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p7809[0...59]
EEPROM download device / file name / Downl Device/File
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p7810[0...1]
EEPROM physical address for reading and writing / Physical addr
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF hex
0000 hex
r7811
EEPROM read value for physical access / Read value
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7817
EEPROM download block length / Downl block length
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p7818[0...2]
EEPROM download address information block / Downl addr_info
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1667
SINAMICS parameters
3.2 SINAMICS parameters
p7819[0...31]
EEPROM download data / Downl data
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p7820
DRIVE-CLiQ component component number / DQ comp_no
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p7821
DRIVE-CLiQ component parameter number / DQ par_no
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p7822[0...1]
DRIVE-CLiQ component parameter index/number / DQ par_index/qty
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
[0] 0
[1] 1
r7823[0...254]
DRIVE-CLiQ component read parameter value / Read DQ value
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7825[0...6]
DRIVE-CLiQ component versions / DQ comp version
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1668
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p7826
Firmware update automatic / FW update auto
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
1
r7827
Firmware update progress display / FW update progress
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p7828[0...1]
Firmware download component number / FW downl comp_no
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
399
0
p7829
Activate firmware download / FW download act
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1
999
0
p7830
Telegram diagnostics selection / Tel diag sel
ENC, HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
r7831[0...23]
Telegram diagnostics signals / Tel diag sig
ENC, HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
15157
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1669
SINAMICS parameters
3.2 SINAMICS parameters
r7832[0...23]
Telegram diagnostics numerical format / Tel diag format
ENC, HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1
14
-
r7833[0...23]
Telegram diagnostics unsigned / Tel diag unsign
ENC, HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7834[0...23]
Telegram diagnostics signed / Tel diag sign
ENC, HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Integer32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7835[0...23]
Telegram diagnostics real / Tel diag real
ENC, HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7836[0...23]
Telegram diagnostics unit / Tel diag unit
ENC, HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1
147
-
r7843[0...20]
Memory card serial number / Mem_card ser_no
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1670
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r7844[0...3]
Memory card/device memory firmware version / Mem_crd/dev_mem FW
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7850[0...n]
Drive object operational/not operational / DO ready for op
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Integer16
Dynamic index: r0095
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-32786
32767
-
p7852
Number of indices for r7853 / Qty indices r7853
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
200
1
r7853[0...n]
Component available/not available / Comp present
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: p7852
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF hex
-
p7857
Sub-boot mode / Sub-boot mode
A_INF, B_INF, ENC,
Can be changed: T, U
Calculated: -
Access level: 4
HLA, HUB, R_INF,
Data type: Integer16
Dynamic index: -
Function diagram: -
S_INF, SERVO,
P-Group: -
Unit group: -
Unit selection: -
SERVO_AC, TB30,
TM120, TM15, TM150,
Not for motor type: -
Scaling: -
Expert list: 1
TM15DI_DO, TM17,
Min:
Max:
Factory setting:
TM31, TM41,
0
1
1
TM54F_MA,
TM54F_SL, VECTOR,
VECTOR_AC
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1671
SINAMICS parameters
3.2 SINAMICS parameters
p7859[0...199]
Component number global / Comp_no global
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-32786
32767
0
r7867
Status/configuration changes global / Changes global
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7868[0...24]
Configuration changes drive object reference / Config_chg DO ref
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7869[0...24]
Status changes drive object reference / Status_chg DO ref
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7870[0...8]
Configuration changes global / Config_chg global
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7871[0...15]
Configuration changes drive object / Config_chg DO
HUB, TB30, TM120,
Can be changed: -
Calculated: -
Access level: 4
TM15, TM150,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
TM15DI_DO, TM17,
P-Group: -
Unit group: -
Unit selection: -
TM31, TM41
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1672
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r7871[0...15]
Configuration changes drive object / Config_chg DO
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7871[0...15]
Configuration changes drive object / Config_chg DO
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7871[0...15]
Configuration changes drive object / Config_chg DO
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 4
S_INF
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7871[0...15]
Configuration changes drive object / Config_chg DO
TM54F_MA, TM54F_SL Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7871[0...15]
Configuration changes drive object / Config_chg DO
ENC
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7872[0...3]
Drive object status changes / DO stat_chg
All objects
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1673
SINAMICS parameters
3.2 SINAMICS parameters
r7873[0...15]
GUID drive unit / GUID Drv_unit
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p7880[0...254]
Setpoint overlap-capable component (t_deriv action overlapping) / t_deriv_overlap
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1.00000 [µs]
1000.00000 [µs]
-1.00000 [µs]
p7881[0...254]
Actual value provision minimum (t_provmin) / t_provmin
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1.00000 [µs]
1000.00000 [µs]
-1.00000 [µs]
p7882[0...510]
Unique component identification / SAC-ID
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
FFFF FFFF hex
p7883[0...254]
Scaling factor for t_ready / t_derivative / Scal t_rdy/t_deriv
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Integer32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1 [Hz]
2147483647 [Hz]
-1 [Hz]
p7884[0...254]
Feature bits / Feature bits
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Integer32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1
2147483647
-1
Machine data and parameters
1674
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p7885[0...254]
Actual value provision earliest (t_ready) / t_ready
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1.00000 [µs]
1000.00000 [µs]
-1.00000 [µs]
p7886[0...254]
Setpoint acceptance latest (t_derivative) / t_derivative
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1.00000 [ms]
1000.00000 [ms]
-1.00000 [ms]
p7887[0...254]
Signal run time to the component (t_signal) / t_signal
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1.00000 [µs]
1000.00000 [µs]
-1.00000 [µs]
p7900[0...23]
Drive objects priority / DO priority
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
r7901[0...81]
Sampling times / t_samp
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [µs]
- [µs]
- [µs]
r7903
Hardware sampling times still assignable / HW t_samp free
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1675
SINAMICS parameters
3.2 SINAMICS parameters
p8500[0...7]
BI: Input signal bit-serially 0 / Input_sig bit 0
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2195
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p8501[0...21]
BI: Input signal bit-serially 1 / Input_sig bit 1
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2195
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p8502
CI: Input signal word-serially 0 / Input_sig word 0
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 2195
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p8503
CI: Input signal word-serially 1 / Input_sig word 1
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 2195
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p8504
CI: Input signal word-serially 2 / Input_sig word 2
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 2195
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p8505
CI: Input signal word-serially 3 / Input_sig word 3
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 2195
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1676
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r8510.0...7
BO: Output signal bit-serially 0 / Outp_sig bit 0
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: 2195
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8511.0...21
BO: Output signal bit-serially 1 / Outp_sig bit 1
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: 2195
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8512
CO: Output signal word-serially 0 / Outp_sig word 0
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2195
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r8513
CO: Output signal word-serially 1 / Outp_sig word 1
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2195
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r8514
CO: Output signal word-serially 2 / Outp_sig word 2
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2195
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r8515
CO: Output signal word-serially 3 / Outp_sig word 3
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2195
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1677
SINAMICS parameters
3.2 SINAMICS parameters
p8550
AOP LOCAL/REMOTE / AOP LOCAL/REMOTE
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 1001 bin
r8570[0...39]
Macro drive object / Macro DO
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_DP,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S_AC_PN,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, HLA,
Not for motor type: -
Scaling: -
Expert list: 0
R_INF, S_INF, SERVO,
Min:
Max:
Factory setting:
SERVO_AC, TM120,
-
-
-
TM150, TM15DI_DO,
TM31, VECTOR,
VECTOR_AC
r8571[0...39]
Macro Binector Input (BI) / Macro BI
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_DP,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S_AC_PN,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, HLA,
Not for motor type: -
Scaling: -
Expert list: 0
R_INF, S_INF, SERVO,
Min:
Max:
Factory setting:
SERVO_AC, TB30,
-
-
-
TM15DI_DO, TM31,
VECTOR, VECTOR_AC
r8572[0...39]
Macro Connector Inputs (CI) for speed setpoints / Macro CI n_set
A_INF, B_INF, HLA,
Can be changed: -
Calculated: -
Access level: 1
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: -
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r8573[0...39]
Macro Connector Inputs (CI) for torque setpoints / Macro CI M_set
A_INF, B_INF, HLA,
Can be changed: -
Calculated: -
Access level: 1
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: -
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1678
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r8585
Macro execution actual / Macro executed
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S_AC_PN,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, HLA,
Not for motor type: -
Scaling: -
Expert list: 0
R_INF, S_INF, SERVO,
Min:
Max:
Factory setting:
SERVO_AC, TB30,
-
-
-
TM120, TM150,
TM15DI_DO, TM31,
VECTOR, VECTOR_AC
r8600
CAN device type / Device type
CU_S120_DP (CAN),
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8601
CAN error register / Error register
CU_S120_DP (CAN),
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8602
CAN SYNC object / SYNC object
CU_S120_DP (CAN),
Can be changed: T
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0080 hex
p8603
CAN COB-ID Emergency Message / COB-ID emerg msg
CU_S120_DP (CAN),
Can be changed: T
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1679
SINAMICS parameters
3.2 SINAMICS parameters
p8604[0...1]
CAN life guarding / Life guarding
CU_S120_DP (CAN),
Can be changed: T
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p8606
CAN Producer Heartbeat Time / Prod Heartb Time
CU_S120_DP (CAN),
Can be changed: T
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
65535 [ms]
0 [ms]
r8607[0...3]
CAN Identity Object / Identity object
CU_S120_DP (CAN),
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8608[0...1]
CAN Clear Bus Off Error / Clear bus off err
CU_S120_DP (CAN),
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p8609[0...1]
CAN Error Behavior / Error behavior
CU_S120_DP (CAN),
Can be changed: T
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
1
r8610[0...1]
CAN First Server SDO / First server SDO
CU_S120_DP (CAN),
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1680
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8611[0...82]
CAN Pre-defined Error Field / Pre_def err field
CU_S120_DP (CAN),
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF 1000 hex
0000 hex
p8612[0...1]
CAN drive object server SDO / DO server SDO
CU_S120_DP (CAN),
Can be changed: T
Calculated: -
Access level: 3
CU_S120_PN (CAN),
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO (CAN), VECTOR
P-Group: Communications
Unit group: -
Unit selection: -
(CAN)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0581 hex
8000 067F hex
8000 0000 hex
p8620
CAN Node-ID / Node ID
CU_S120_DP (CAN),
Can be changed: T
Calculated: -
Access level: 2
CU_S120_PN (CAN)
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
127
126
r8621
CAN Node-ID active / Node ID act
CU_S120_DP (CAN),
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8622
CAN bit rate / Bit rate
CU_S120_DP (CAN),
Can be changed: T
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
7
6
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1681
SINAMICS parameters
3.2 SINAMICS parameters
p8623[0...7]
CAN Bit Timing selection / Bit timing sel
CU_S120_DP (CAN),
Can be changed: T
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
000F 7FFF hex
[0] 1405 hex
[1] 1605 hex
[2] 1C05 hex
[3] 1C0B hex
[4] 1C17 hex
[5] 1C3B hex
[6] 0002 1C15 hex
[7] 0004 1C2B hex
p8630[0...2]
CAN virtual objects / Virtual objects
CU_S120_DP (CAN),
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p8641
CAN Abort Connection Option Code / Abort con opt code
SERVO (CAN), VECTOR
Can be changed: T
Calculated: -
Access level: 3
(CAN)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
3
r8680[0...36]
CAN Diagnosis Hardware / Diagnostics HW
CU_S120_DP (CAN),
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8684
CAN NMT state after booting / NMT state aft boot
CU_S120_DP (CAN),
Can be changed: T
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
4
127
127
Machine data and parameters
1682
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8685
CAN NMT states / NMT states
CU_S120_DP (CAN),
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
129
127
p8699
CAN: RPDO monitoring time / RPDO t_mon
CU_S120_DP (CAN),
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
65535000 [ms]
0 [ms]
p8700[0...1]
CAN Receive PDO 1 / Receive PDO 1
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204, 9206
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
8000 06DF hex
[0] 8000 06DF hex
[1] 00FE hex
p8701[0...1]
CAN Receive PDO 2 / Receive PDO 2
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204, 9206
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
8000 06DF hex
[0] 8000 06DF hex
[1] 00FE hex
p8702[0...1]
CAN Receive PDO 3 / Receive PDO 3
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204, 9206
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
8000 06DF hex
[0] 8000 06DF hex
[1] 00FE hex
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1683
SINAMICS parameters
3.2 SINAMICS parameters
p8703[0...1]
CAN Receive PDO 4 / Receive PDO 4
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204, 9206
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
8000 06DF hex
[0] 8000 06DF hex
[1] 00FE hex
p8704[0...1]
CAN Receive PDO 5 / Receive PDO 5
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
8000 06DF hex
[0] 8000 06DF hex
[1] 00FE hex
p8705[0...1]
CAN Receive PDO 6 / Receive PDO 6
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
8000 06DF hex
[0] 8000 06DF hex
[1] 00FE hex
p8706[0...1]
CAN Receive PDO 7 / Receive PDO 7
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
8000 06DF hex
[0] 8000 06DF hex
[1] 00FE hex
p8707[0...1]
CAN Receive PDO 8 / Receive PDO 8
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
8000 06DF hex
[0] 8000 06DF hex
[1] 00FE hex
Machine data and parameters
1684
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8710[0...3]
CAN Receive Mapping for RPDO 1 / Mapping RPDO 1
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204, 9206
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p8711[0...3]
CAN Receive Mapping for RPDO 2 / Mapping RPDO 2
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204, 9206
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p8712[0...3]
CAN Receive Mapping for RPDO 3 / Mapping RPDO 3
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204, 9206
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p8713[0...3]
CAN Receive Mapping for RPDO 4 / Mapping RPDO 4
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204, 9206
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p8714[0...3]
CAN Receive Mapping for RPDO 5 / Mapping RPDO 5
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p8715[0...3]
CAN Receive Mapping for RPDO 6 / Mapping RPDO 6
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1685
SINAMICS parameters
3.2 SINAMICS parameters
p8716[0...3]
CAN Receive Mapping for RPDO 7 / Mapping RPDO 7
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p8717[0...3]
CAN Receive Mapping for RPDO 8 / Mapping RPDO 8
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9204
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p8720[0...4]
CAN Transmit PDO 1 / Transmit PDO 1
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208, 9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
C000 06DF hex
[0] C000 06DF hex
[1] 00FE hex
[2] 0000 hex
[3] 0000 hex
[4] 0000 hex
p8721[0...4]
CAN Transmit PDO 2 / Transmit PDO 2
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208, 9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
C000 06DF hex
[0] C000 06DF hex
[1] 00FE hex
[2] 0000 hex
[3] 0000 hex
[4] 0000 hex
Machine data and parameters
1686
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8722[0...4]
CAN Transmit PDO 3 / Transmit PDO 3
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208, 9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
C000 06DF hex
[0] C000 06DF hex
[1] 00FE hex
[2] 0000 hex
[3] 0000 hex
[4] 0000 hex
p8723[0...4]
CAN Transmit PDO 4 / Transmit PDO 4
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208, 9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
C000 06DF hex
[0] C000 06DF hex
[1] 00FE hex
[2] 0000 hex
[3] 0000 hex
[4] 0000 hex
p8724[0...4]
CAN Transmit PDO 5 / Transmit PDO 5
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
C000 06DF hex
[0] C000 06DF hex
[1] 00FE hex
[2] 0000 hex
[3] 0000 hex
[4] 0000 hex
p8725[0...4]
CAN Transmit PDO 6 / Transmit PDO 6
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
C000 06DF hex
[0] C000 06DF hex
[1] 00FE hex
[2] 0000 hex
[3] 0000 hex
[4] 0000 hex
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1687
SINAMICS parameters
3.2 SINAMICS parameters
p8726[0...4]
CAN Transmit PDO 7 / Transmit PDO 7
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
C000 06DF hex
[0] C000 06DF hex
[1] 00FE hex
[2] 0000 hex
[3] 0000 hex
[4] 0000 hex
p8727[0...4]
CAN Transmit PDO 8 / Transmit PDO 8
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
C000 06DF hex
[0] C000 06DF hex
[1] 00FE hex
[2] 0000 hex
[3] 0000 hex
[4] 0000 hex
p8730[0...3]
CAN Transmit Mapping for TPDO 1 / Mapping TPDO 1
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208, 9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p8731[0...3]
CAN Transmit Mapping for TPDO 2 / Mapping TPDO 2
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208, 9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p8732[0...3]
CAN Transmit Mapping for TPDO 3 / Mapping TPDO 3
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208, 9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
Machine data and parameters
1688
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8733[0...3]
CAN Transmit Mapping for TPDO 4 / Mapping TPDO 4
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208, 9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p8734[0...3]
CAN Transmit Mapping for TPDO 5 / Mapping TPDO 5
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p8735[0...3]
CAN Transmit Mapping for TPDO 6 / Mapping TPDO 6
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p8736[0...3]
CAN Transmit Mapping for TPDO 7 / Mapping TPDO 7
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p8737[0...3]
CAN Transmit Mapping for TPDO 8 / Mapping TPDO 8
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: 9208
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
r8739
Minimum CAN processing time / t_processing min
CU_S120_DP (CAN),
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [µs]
- [µs]
- [µs]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1689
SINAMICS parameters
3.2 SINAMICS parameters
r8742[0...1]
CAN PDO available number / PDO available no.
CU_S120_DP (CAN),
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8743[0...7]
CAN device module assignment / Device mod assign
CU_S120_DP (CAN),
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN (CAN)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8744
CAN PDO mapping configuration / PDO Mapping config
SERVO (CAN), VECTOR
Can be changed: T
Calculated: -
Access level: 2
(CAN)
Data type: Integer16
Dynamic index: -
Function diagram: 9204, 9206,
9208, 9210
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
2
2
r8745[0...15]
CO: CAN free PZD receive objects 16 bit / Free PZD recv 16
SERVO (CAN), VECTOR
Can be changed: -
Calculated: -
Access level: 3
(CAN)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8746[0...15]
CI: CAN free PZD send objects 16 bit / Free PZD send 16
SERVO (CAN), VECTOR
Can be changed: T, U
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r8747[0...7]
CO: CAN free PZD receive objects 32 bit / Free PZD recv 32
SERVO (CAN), VECTOR
Can be changed: -
Calculated: -
Access level: 3
(CAN)
Data type: Integer32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1690
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8748[0...7]
CI: CAN free PZD send objects 32 bit / Free PZD send 32
SERVO (CAN), VECTOR
Can be changed: T, U
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r8750[0...15]
CAN mapped 16-bit receive objects / RPDO 16 mapped
SERVO (CAN), VECTOR
Can be changed: -
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8751[0...15]
CAN mapped 16-bit transmit objects / TPDO 16 mapped
SERVO (CAN), VECTOR
Can be changed: -
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8760[0...14]
CAN mapped 32-bit receive objects / RPDO 32 mapped
SERVO (CAN), VECTOR
Can be changed: -
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8761[0...14]
CAN mapped 32-bit transmit objects / TPDO 32 mapped
SERVO (CAN), VECTOR
Can be changed: -
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8762
CO: CAN operating mode display / Op mode display
SERVO (CAN), VECTOR
Can be changed: -
Calculated: -
Access level: 3
(CAN)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1691
SINAMICS parameters
3.2 SINAMICS parameters
r8784
CO: CAN status word / Status word
SERVO (CAN), VECTOR
Can be changed: -
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned16
Dynamic index: -
Function diagram: 9226
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8785
BI: CAN status word bit 8 / Status word bit 8
SERVO (CAN), VECTOR
Can be changed: T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9226
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p8786
BI: CAN status word bit 14 / Status word bit 14
SERVO (CAN), VECTOR
Can be changed: T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9226
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p8787
BI: CAN status word bit 15 / Status word bit 15
SERVO (CAN), VECTOR
Can be changed: T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9226
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p8790
CAN control word - auto interconnection / STW interc auto
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p8791
CAN stop option code / Stop opt_code
SERVO (CAN), VECTOR
Can be changed: C1(3), T
Calculated: -
Access level: 3
(CAN)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1
3
-1
Machine data and parameters
1692
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r8792[0]
CO: CAN velocity mode I16 setpoint / Vel mod I16 set
SERVO (CAN), VECTOR
Can be changed: -
Calculated: -
Access level: 3
(CAN)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8795.0...15
CO/BO: CAN control word / Control word
SERVO (CAN), VECTOR
Can be changed: -
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8796[0]
CO: CAN profile velocity mode I32 setpoints / Pr vel mo I32 set
SERVO (CAN), VECTOR
Can be changed: -
Calculated: -
Access level: 3
(CAN)
Data type: Integer32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8797[0]
CO: CAN profile torque mode I16 setpoints / Pr Tq mod I16 set
SERVO (CAN), VECTOR
Can be changed: -
Calculated: -
Access level: 3
(CAN)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8798[0...1]
CAN speed conversion factor / n_conv_factor
SERVO (CAN), VECTOR
Can be changed: T
Calculated: -
Access level: 3
(CAN)
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
4294967295
1
p8806[0...53]
Identification and Maintenance 1 / I&M 1
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1693
SINAMICS parameters
3.2 SINAMICS parameters
p8807[0...15]
Identification and Maintenance 2 / I&M 2
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
p8808[0...53]
Identification and Maintenance 3 / I&M 3
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
r8809[0...53]
Identification and Maintenance 4 / I&M 4
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8811
SINAMICS Link project selection / Project sel
CU_S120_DP (PN
Can be changed: C1(1)
Calculated: -
Access level: 3
CBE20), CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: 2197, 2198
(PN CBE20)
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
8
64
64
p8812[0...1]
SINAMICS Link clock cycle settings / Clock cyc set
CU_S120_DP (PN
Can be changed: C1(1)
Calculated: -
Access level: 3
CBE20), CU_S120_PN
Data type: Unsigned16
Dynamic index: -
Function diagram: 2197, 2198
(PN CBE20)
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2000
[0] 1
[1] 2000
p8815[0...1]
IF1/IF2 PZD functionality selection / IF1/IF2 PZD fct
CU_S120_DP,
Can be changed: C1(1)
Calculated: -
Access level: 3
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
2
1
Machine data and parameters
1694
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8815[0...1]
IF1/IF2 PZD functionality selection / IF1/IF2 PZD fct
CU_S_AC_DP,
Can be changed: C1(1)
Calculated: -
Access level: 9
CU_S_AC_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
2
1
r8828[0...1]
CBE41 temperature / CBE41 temp
CU_S_AC_DP (CBE41
Can be changed: -
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN), CU_S120_PN
Not for motor type: -
Scaling: p2006
Expert list: 1
(CBE41 TSN)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
p8835
CBE20 firmware selection / CBE20 FW sel
CU_S120_DP (PN
Can be changed: C1(1)
Calculated: -
Access level: 3
CBE20), CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: 2197, 2198
(PN CBE20)
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
99
1
p8836
SINAMICS link node address / Node address
CU_S120_DP (PN
Can be changed: C1(1)
Calculated: -
Access level: 3
CBE20), CU_S120_PN
Data type: Unsigned16
Dynamic index: -
Function diagram: 2198
(PN CBE20)
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
64
0
p8837
IF2 STW1.10 = 0 mode / IF2 STW1.10=0
A_INF, B_INF, ENC,
Can be changed: T
Calculated: -
Access level: 3
HLA, R_INF, S_INF,
Data type: Integer16
Dynamic index: -
Function diagram: -
SERVO, SERVO_AC,
P-Group: Communications
Unit group: -
Unit selection: -
TM41, VECTOR,
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
2
p8839[0...1]
PZD interface hardware assignment / PZD intf HW assign
CU_S120_DP,
Can be changed: C1(1)
Calculated: -
Access level: 3
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: 2197, 2198
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
99
99
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1695
SINAMICS parameters
3.2 SINAMICS parameters
p8839[0...1]
PZD interface hardware assignment / PZD intf HW assign
CU_S_AC_DP,
Can be changed: C1(1)
Calculated: -
Access level: 9
CU_S_AC_PN
Data type: Integer16
Dynamic index: -
Function diagram: 2197, 2198
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
99
99
p8840
COMM BOARD monitoring time / CB t_mon
CU_S120_DP (COMM
Can be changed: T, U
Calculated: -
Access level: 3
BOARD, COMM BOARD,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
PN CBE20, PN CBE20),
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN (COMM
BOARD, COMM BOARD,
Not for motor type: -
Scaling: -
Expert list: 1
PN CBE20, PN CBE20)
Min:
Max:
Factory setting:
0 [ms]
65535000 [ms]
20 [ms]
p8841[0...239]
COMM BOARD send configuration data / CB s config_dat
CU_S120_DP (COMM
Can be changed: T, U
Calculated: -
Access level: 3
BOARD, COMM BOARD,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
PN CBE20, PN CBE20),
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN (COMM
BOARD, COMM BOARD,
Not for motor type: -
Scaling: -
Expert list: 1
PN CBE20, PN CBE20)
Min:
Max:
Factory setting:
0
65535
0
p8842
Activate COMM BOARD send configuration / CB s config act
CU_S120_DP (COMM
Can be changed: T, U
Calculated: -
Access level: 3
BOARD, COMM BOARD,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2199, 2200
PN CBE20, PN CBE20),
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN (COMM
BOARD, COMM BOARD,
Not for motor type: -
Scaling: -
Expert list: 1
PN CBE20, PN CBE20)
Min:
Max:
Factory setting:
0
1
0
r8843.0...2
BO: IF2 PZD state / IF2 PZD state
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: 2410
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8844
IF2 fault delay / IF2 flt delay
A_INF, B_INF, ENC,
Can be changed: T, U
Calculated: -
Access level: 3
HLA, R_INF, S_INF,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2410
SERVO, SERVO_AC,
P-Group: Communications
Unit group: -
Unit selection: -
TM41, VECTOR,
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [s]
100 [s]
0 [s]
Machine data and parameters
1696
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8848
IF2 PZD sampling time / IF2 PZD t_sample
CU_S_AC_DP,
Can be changed: C1(3)
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.00 [ms]
16.00 [ms]
4.00 [ms]
r8849[0...139]
COMM BOARD receive configuration data / CB r config_dat
CU_S120_DP (COMM
Can be changed: -
Calculated: -
Access level: 3
BOARD, COMM BOARD,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
PN CBE20, PN CBE20),
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN (COMM
BOARD, COMM BOARD,
Not for motor type: -
Scaling: -
Expert list: 1
PN CBE20, PN CBE20)
Min:
Max:
Factory setting:
-
-
-
r8850[0...19]
CO: IF2 PZD receive word / IF2 PZD recv word
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: 2491
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8850[0...21]
CO: IF2 PZD receive word / IF2 PZD recv word
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Integer16
Dynamic index: -
Function diagram: 2485, 2491,
9204, 9206
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8850[0...31]
CO: IF2 PZD receive word / IF2 PZD recv word
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 2485, 2491,
9204, 9206
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8850[0...9]
CO: IF2 PZD receive word / IF2 PZD recv word
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF
Data type: Integer16
Dynamic index: -
Function diagram: 2491
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1697
SINAMICS parameters
3.2 SINAMICS parameters
r8850[0...4]
CO: IF2 PZD receive word / IF2 PZD recv word
TB30, TM120, TM150,
Can be changed: -
Calculated: -
Access level: 3
TM15DI_DO, TM31
Data type: Integer16
Dynamic index: -
Function diagram: 2491
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8850[0...3]
CO: IF2 PZD receive word / IF2 PZD recv word
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 2485, 2491,
9204, 9206
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8851[0...24]
CI: IF2 PZD send word / IF2 PZD send word
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 2493, 9210
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p8851[0...27]
CI: IF2 PZD send word / IF2 PZD send word
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 2487, 9208
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p8851[0...31]
CI: IF2 PZD send word / IF2 PZD send word
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 2487, 9208
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p8851[0...9]
CI: IF2 PZD send word / IF2 PZD send word
A_INF, B_INF, R_INF,
Can be changed: T, U
Calculated: -
Access level: 3
S_INF
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 2493, 9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1698
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8851[0...4]
CI: IF2 PZD send word / IF2 PZD send word
TB30, TM120, TM150,
Can be changed: T, U
Calculated: -
Access level: 3
TM15DI_DO, TM31
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 2493, 9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p8851[0...11]
CI: IF2 PZD send word / IF2 PZD send word
ENC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 2487, 9208
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r8853[0...24]
IF2 diagnostics PZD send / IF2 diag PZD send
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2493
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8853[0...27]
IF2 diagnostics PZD send / IF2 diag PZD send
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Unsigned16
Dynamic index: -
Function diagram: 2487, 9208,
9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8853[0...31]
IF2 diagnostics PZD send / IF2 diag PZD send
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2487, 9208,
9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8853[0...9]
IF2 diagnostics PZD send / IF2 diag PZD send
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: 2493
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1699
SINAMICS parameters
3.2 SINAMICS parameters
r8853[0...4]
IF2 diagnostics PZD send / IF2 diag PZD send
TB30, TM120, TM150,
Can be changed: -
Calculated: -
Access level: 3
TM15DI_DO, TM31
Data type: Unsigned16
Dynamic index: -
Function diagram: 2493
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8853[0...11]
IF2 diagnostics PZD send / IF2 diag PZD send
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2487, 9208,
9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8854
COMM BOARD state / CB state
CU_S120_DP (COMM
Can be changed: -
Calculated: -
Access level: 3
BOARD, COMM BOARD,
Data type: Integer16
Dynamic index: -
Function diagram: -
PN CBE20, PN CBE20),
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN (COMM
BOARD, COMM BOARD,
Not for motor type: -
Scaling: -
Expert list: 1
PN CBE20, PN CBE20)
Min:
Max:
Factory setting:
0
255
-
p8856[0...29]
COMM BOARD write test channel / CB test chan write
CU_S120_DP (COMM
Can be changed: T, U
Calculated: -
Access level: 8
BOARD, COMM BOARD,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
PN CBE20, PN CBE20),
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN (COMM
BOARD, COMM BOARD,
Not for motor type: -
Scaling: -
Expert list: 0
PN CBE20, PN CBE20)
Min:
Max:
Factory setting:
0
65535
0
r8857[0...29]
COMM BOARD read test channel / CB test chan read
CU_S120_DP (COMM
Can be changed: -
Calculated: -
Access level: 8
BOARD, COMM BOARD,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
PN CBE20, PN CBE20),
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN (COMM
BOARD, COMM BOARD,
Not for motor type: -
Scaling: -
Expert list: 0
PN CBE20, PN CBE20)
Min:
Max:
Factory setting:
-
-
-
r8858[0...39]
COMM BOARD read diagnostics channel / CB diag_chan read
CU_S120_DP (COMM
Can be changed: -
Calculated: -
Access level: 3
BOARD, COMM BOARD,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
PN CBE20, PN CBE20),
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN (COMM
BOARD, COMM BOARD,
Not for motor type: -
Scaling: -
Expert list: 1
PN CBE20, PN CBE20)
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1700
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r8859[0...7]
COMM BOARD identification data / CB ID_data
CU_S120_DP (COMM
Can be changed: -
Calculated: -
Access level: 3
BOARD, COMM BOARD,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
PN CBE20, PN CBE20),
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN (COMM
BOARD, COMM BOARD,
Not for motor type: -
Scaling: -
Expert list: 1
PN CBE20, PN CBE20)
Min:
Max:
Factory setting:
0
65535
-
r8860[0...20]
CO: IF2 PZD receive double word / IF2 PZD recv DW
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Integer32
Dynamic index: -
Function diagram: 2485, 9204,
9206
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8860[0...30]
CO: IF2 PZD receive double word / IF2 PZD recv DW
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: -
Function diagram: 2485, 9204,
9206
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8860[0...2]
CO: IF2 PZD receive double word / IF2 PZD recv DW
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: -
Function diagram: 2485, 9204,
9206
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8861[0...26]
CI: IF2 PZD send double word / IF2 PZD send DW
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 2487, 9208,
9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1701
SINAMICS parameters
3.2 SINAMICS parameters
p8861[0...30]
CI: IF2 PZD send double word / IF2 PZD send DW
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 2487, 9208,
9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p8861[0...10]
CI: IF2 PZD send double word / IF2 PZD send DW
ENC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 2487, 9208,
9210
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r8863[0...26]
IF2 diagnostics PZD send double word / IF2 diag send DW
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Unsigned32
Dynamic index: -
Function diagram: 2487
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8863[0...30]
IF2 diagnostics PZD send double word / IF2 diag send DW
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 2487
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8863[0...10]
IF2 diagnostics PZD send double word / IF2 diag send DW
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 2487
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8864
IF1 PROFIdrive first supplementary telegram selection / IF1 Pd 1. sup_tel
HLA, SERVO,
Can be changed: C2(1), T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2423
VECTOR_AC
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
700
999
999
Machine data and parameters
1702
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8865
IF1 PROFIdrive second supplementary telegram selection / IF1 Pd 2. sup_tel
HLA, SERVO,
Can be changed: C2(1), T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2423
VECTOR_AC
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
700
999
999
r8867[0...1]
IF2 PZD maximum interconnected / IF2 PZDmaxIntercon
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
-
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
p8870[0...15]
SINAMICS Link PZD receive word / PZD recv word
A_INF (PN CBE20),
Can be changed: T
Calculated: -
Access level: 3
B_INF (PN CBE20),
Data type: Unsigned16
Dynamic index: -
Function diagram: 2198, 2199
CU_S120_DP (PN
P-Group: Communications
Unit group: -
Unit selection: -
CBE20), CU_S120_PN
(PN CBE20), ENC (PN
Not for motor type: -
Scaling: -
Expert list: 1
CBE20), HLA (PN
Min:
Max:
Factory setting:
CBE20), R_INF (PN
0
32
0
CBE20), S_INF (PN
CBE20), SERVO (PN
CBE20), TB30 (PN
CBE20), TM120 (PN
CBE20), TM15 (PN
CBE20), TM150 (PN
CBE20), TM15DI_DO
(PN CBE20), TM17 (PN
CBE20), TM31 (PN
CBE20), TM41 (PN
CBE20)
p8870[0...15]
SINAMICS Link PZD receive word / PZD recv word
SERVO_AC (PN CBE20)
Can be changed: T
Calculated: -
Access level: 9
Data type: Unsigned16
Dynamic index: -
Function diagram: 2198, 2199
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
32
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1703
SINAMICS parameters
3.2 SINAMICS parameters
p8870[0...31]
SINAMICS Link PZD receive word / PZD recv word
VECTOR_AC (PN CBE20) Can be changed: T
Calculated: -
Access level: 9
Data type: Unsigned16
Dynamic index: -
Function diagram: 2198, 2199
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
32
0
p8870[0...31]
SINAMICS Link PZD receive word / PZD recv word
VECTOR (PN CBE20)
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2198, 2199
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
32
0
p8871[0...15]
SINAMICS Link PZD send word / PZD send word
A_INF (PN CBE20),
Can be changed: T
Calculated: -
Access level: 3
B_INF (PN CBE20),
Data type: Unsigned16
Dynamic index: -
Function diagram: 2198, 2199
CU_S120_DP (PN
P-Group: Communications
Unit group: -
Unit selection: -
CBE20), CU_S120_PN
(PN CBE20), ENC (PN
Not for motor type: -
Scaling: -
Expert list: 1
CBE20), HLA (PN
Min:
Max:
Factory setting:
CBE20), R_INF (PN
0
32
0
CBE20), S_INF (PN
CBE20), SERVO (PN
CBE20), TB30 (PN
CBE20), TM120 (PN
CBE20), TM15 (PN
CBE20), TM150 (PN
CBE20), TM15DI_DO
(PN CBE20), TM17 (PN
CBE20), TM31 (PN
CBE20), TM41 (PN
CBE20)
p8871[0...15]
SINAMICS Link PZD send word / PZD send word
SERVO_AC (PN CBE20)
Can be changed: T
Calculated: -
Access level: 9
Data type: Unsigned16
Dynamic index: -
Function diagram: 2198, 2199
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
32
0
p8871[0...31]
SINAMICS Link PZD send word / PZD send word
VECTOR_AC (PN CBE20) Can be changed: T
Calculated: -
Access level: 9
Data type: Unsigned16
Dynamic index: -
Function diagram: 2198, 2199
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
32
0
Machine data and parameters
1704
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8871[0...31]
SINAMICS Link PZD send word / PZD send word
VECTOR (PN CBE20)
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2198, 2199
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
32
0
p8872[0...15]
SINAMICS Link PZD receive address / PZD recv addr
A_INF (PN CBE20),
Can be changed: T
Calculated: -
Access level: 3
B_INF (PN CBE20),
Data type: Unsigned16
Dynamic index: -
Function diagram: 2198, 2199
CU_S120_DP (PN
P-Group: Communications
Unit group: -
Unit selection: -
CBE20), CU_S120_PN
(PN CBE20), ENC (PN
Not for motor type: -
Scaling: -
Expert list: 1
CBE20), HLA (PN
Min:
Max:
Factory setting:
CBE20), R_INF (PN
0
64
0
CBE20), S_INF (PN
CBE20), SERVO (PN
CBE20), TB30 (PN
CBE20), TM120 (PN
CBE20), TM15 (PN
CBE20), TM150 (PN
CBE20), TM15DI_DO
(PN CBE20), TM17 (PN
CBE20), TM31 (PN
CBE20), TM41 (PN
CBE20)
p8872[0...15]
SINAMICS Link PZD receive address / PZD recv addr
SERVO_AC (PN CBE20)
Can be changed: T
Calculated: -
Access level: 9
Data type: Unsigned16
Dynamic index: -
Function diagram: 2198, 2199
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
64
0
p8872[0...31]
SINAMICS Link PZD receive address / PZD recv addr
VECTOR_AC (PN CBE20) Can be changed: T
Calculated: -
Access level: 9
Data type: Unsigned16
Dynamic index: -
Function diagram: 2198, 2199
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
64
0
p8872[0...31]
SINAMICS Link PZD receive address / PZD recv addr
VECTOR (PN CBE20)
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2198, 2199
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
64
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1705
SINAMICS parameters
3.2 SINAMICS parameters
r8874[0...19]
IF2 diagnostics bus address PZD receive / IF2 diag addr recv
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8874[0...21]
IF2 diagnostics bus address PZD receive / IF2 diag addr recv
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8874[0...31]
IF2 diagnostics bus address PZD receive / IF2 diag addr recv
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8874[0...9]
IF2 diagnostics bus address PZD receive / IF2 diag addr recv
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8874[0...4]
IF2 diagnostics bus address PZD receive / IF2 diag addr recv
TB30, TM120, TM150,
Can be changed: -
Calculated: -
Access level: 3
TM15DI_DO, TM31
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8874[0...3]
IF2 diagnostics bus address PZD receive / IF2 diag addr recv
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1706
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r8875[0...19]
IF2 diagnostics telegram offset PZD receive / IF diag offs recv
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8875[0...21]
IF2 diagnostics telegram offset PZD receive / IF diag offs recv
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8875[0...31]
IF2 diagnostics telegram offset PZD receive / IF diag offs recv
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8875[0...9]
IF2 diagnostics telegram offset PZD receive / IF diag offs recv
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8875[0...4]
IF2 diagnostics telegram offset PZD receive / IF diag offs recv
TB30, TM120, TM150,
Can be changed: -
Calculated: -
Access level: 3
TM15DI_DO, TM31
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8875[0...3]
IF2 diagnostics telegram offset PZD receive / IF diag offs recv
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1707
SINAMICS parameters
3.2 SINAMICS parameters
r8876[0...24]
IF2 diagnostics telegram offset PZD send / IF2 diag offs send
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8876[0...27]
IF2 diagnostics telegram offset PZD send / IF2 diag offs send
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8876[0...31]
IF2 diagnostics telegram offset PZD send / IF2 diag offs send
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8876[0...9]
IF2 diagnostics telegram offset PZD send / IF2 diag offs send
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8876[0...4]
IF2 diagnostics telegram offset PZD send / IF2 diag offs send
TB30, TM120, TM150,
Can be changed: -
Calculated: -
Access level: 3
TM15DI_DO, TM31
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8876[0...11]
IF2 diagnostics telegram offset PZD send / IF2 diag offs send
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1708
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8880[0...15]
BI: IF2 binector-connector converter status word 1 / Bin/con ZSW1
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2489
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0
TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
p8881[0...15]
BI: IF2 binector-connector converter status word 2 / Bin/con ZSW2
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2489
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0
TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
p8882[0...15]
BI: IF2 binector-connector converter status word 3 / Bin/con ZSW3
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2489
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0
TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
p8883[0...15]
BI: IF2 binector-connector converter status word 4 / Bin/con ZSW4
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2489
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0
TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1709
SINAMICS parameters
3.2 SINAMICS parameters
p8884[0...15]
BI: IF2 binector-connector converter status word 5 / Bin/con ZSW5
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2489
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0
TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
p8888[0...4]
IF2 invert binector-connector converter status word / Bin/con ZSW inv
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2489
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0000 0000 0000 0000 bin
TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
r8889[0...4]
CO: IF2 send binector-connector converter status word / Bin/con ZSW send
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
-
TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
r8890.0...15
BO: IF2 PZD1 receive bit-serial / IF2 PZD1 recv bitw
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2485, 2491,
CU_S_AC_PN,
9204, 9206
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HLA, R_INF, S_INF,
Not for motor type: -
Scaling: -
Expert list: 1
SERVO, SERVO_AC,
Min:
Max:
Factory setting:
TB30, TM120, TM150,
-
-
-
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
Machine data and parameters
1710
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r8891.0...15
BO: IF2 PZD2 receive bit-serial / IF2 PZD2 recv bitw
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2485, 2491,
CU_S_AC_PN,
9204, 9206
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HLA, R_INF, S_INF,
Not for motor type: -
Scaling: -
Expert list: 1
SERVO, SERVO_AC,
Min:
Max:
Factory setting:
TB30, TM120, TM150,
-
-
-
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
r8892.0...15
BO: IF2 PZD3 receive bit-serial / IF2 PZD3 recv bitw
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2485, 9204,
CU_S120_DP,
9206
CU_S120_PN, ENC,
P-Group: Communications
Unit group: -
Unit selection: -
HLA, SERVO,
SERVO_AC, TM41,
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR, VECTOR_AC
Min:
Max:
Factory setting:
-
-
-
r8893.0...15
BO: IF2 PZD4 receive bit-serial / IF2 PZD4 recv bitw
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2485, 9204,
CU_S120_DP,
9206
CU_S120_PN, ENC,
P-Group: Communications
Unit group: -
Unit selection: -
HLA, SERVO,
SERVO_AC, TM41,
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR, VECTOR_AC
Min:
Max:
Factory setting:
-
-
-
r8894.0...15
BO: IF2 connector-binector converter binector output / Con/bin outp
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2485, 2491
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
-
TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1711
SINAMICS parameters
3.2 SINAMICS parameters
r8895.0...15
BO: IF2 connector-binector converter binector output / Con/bin outp
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2485, 2491
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
-
TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
p8898[0...1]
IF2 invert connector-binector converter binector output / Con/bin outp inv
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2485, 2491
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0000 0000 0000 0000 bin
TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
p8899[0...1]
CI: IF2 connector-binector converter signal source / Con/bin s_s
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 2485, 2491
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0
TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
p8900[0...239]
IE Name of Station / IE name stn
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8901[0...3]
IE IP address / IE IP addr
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
0
Machine data and parameters
1712
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8902[0...3]
IE default gateway / IE Def Gateway
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
0
p8903[0...3]
IE Subnet Mask / IE Subnet Mask
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
0
p8904
IE DHCP mode / IE DHCP mode
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
p8905
Activate IE interface configuration / IE IF config act
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
p8906
Commissioning tool maximum telegram length / Com tel max
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
2
p8908
Activate FTP / Act FTP
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1713
SINAMICS parameters
3.2 SINAMICS parameters
r8909
PN device ID / PN device ID
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8910[0...239]
IE Name of Station actual / IE name stn act
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8911[0...3]
IE IP address actual / IE IP addr act
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
-
r8912[0...3]
IE default gateway actual / IE Def Gateway act
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
-
r8913[0...3]
IE Subnet Mask actual / IE Subnet Mask act
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
-
r8914
IE DHCP mode actual / IE DHCP mode act
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
-
Machine data and parameters
1714
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r8915[0...5]
IE MAC address / IE MAC addr
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
00FF hex
-
p8920[0...239]
PN name of station / PN name stn
CU_S_AC_PN,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p8920[0...239]
PN name of station / PN name stn
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_DP
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
p8921[0...3]
PN IP address / PN IP addr
CU_S_AC_PN,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
0
p8921[0...3]
PN IP address / PN IP addr
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_DP
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p8922[0...3]
PN Default Gateway / PN Def Gateway
CU_S_AC_PN,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1715
SINAMICS parameters
3.2 SINAMICS parameters
p8922[0...3]
PN Default Gateway / PN Def Gateway
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_DP
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p8923[0...3]
PN Subnet Mask / PN Subnet Mask
CU_S_AC_PN,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
0
p8923[0...3]
PN Subnet Mask / PN Subnet Mask
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_DP
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p8924
PN DHCP Mode / PN DHCP Mode
CU_S_AC_PN,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
p8924
PN DHCP Mode / PN DHCP Mode
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_DP
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
3
0
p8925
Activate PN interface configuration / PN IF config
CU_S_AC_PN,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
Machine data and parameters
1716
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8925
Activate PN interface configuration / PN IF config
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_DP
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
3
0
r8930[0...239]
PN Name of Station actual / PN name stn act
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8930[0...239]
PN Name of Station actual / PN name stn act
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 9
CU_S120_DP
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r8931[0...3]
PN IP address actual / PN IP addr act
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
-
r8931[0...3]
PN IP address actual / PN IP addr act
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 9
CU_S120_DP
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
-
r8932[0...3]
PN Default Gateway actual / PN Def Gateway act
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1717
SINAMICS parameters
3.2 SINAMICS parameters
r8932[0...3]
PN Default Gateway actual / PN Def Gateway act
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 9
CU_S120_DP
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
-
r8933[0...3]
PN Subnet Mask actual / PN Subnet Mask act
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
-
r8933[0...3]
PN Subnet Mask actual / PN Subnet Mask act
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 9
CU_S120_DP
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
-
r8934
PN DHCP Mode actual / PN DHCP Mode act
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
-
r8934
PN DHCP Mode actual / PN DHCP Mode act
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 9
CU_S120_DP
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
3
-
r8935[0...5]
PN MAC address / PN MAC addr
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
00FF hex
-
Machine data and parameters
1718
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r8935[0...5]
PN MAC address / PN MAC addr
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 9
CU_S120_DP
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0000 hex
00FF hex
-
r8936[0...1]
Cyclic connection status / Cyc conn status
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
13
-
r8936[0...1]
Cyclic connection status / Cyc conn status
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 9
CU_S120_DP
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
13
-
r8937[0...5]
Cyclic connection diagnostics / Cycl conn diag
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r8937[0...5]
Cyclic connection diagnostics / Cycl conn diag
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 9
CU_S120_DP
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r8939
PN DAP ID / PN DAP ID
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1719
SINAMICS parameters
3.2 SINAMICS parameters
r8939
PN DAP ID / PN DAP ID
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 9
CU_S120_DP
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
p8940[0...239]
CBExx name of station / CBExx name stat
CU_S_AC_DP (CBE41
Can be changed: T, U
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
-
-
-
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
p8941[0...3]
CBExx IP address / CBExx IP addr
CU_S_AC_DP (CBE41
Can be changed: T, U
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
0
255
0
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
Machine data and parameters
1720
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p8942[0...3]
CBExx default gateway / CBExx def gateway
CU_S_AC_DP (CBE41
Can be changed: T, U
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
0
255
0
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
p8943[0...3]
CBExx subnet mask / CBExx subnet mask
CU_S_AC_DP (CBE41
Can be changed: T, U
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
0
255
0
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
p8944
CBExx DHCP mode / CBExx DHCP mode
CU_S_AC_DP (CBE41
Can be changed: T, U
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
0
3
0
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1721
SINAMICS parameters
3.2 SINAMICS parameters
p8945
CBExx activate configuration of interfaces / CBExx intf config
CU_S_AC_DP (CBE41
Can be changed: T, U
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
0
3
0
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
r8950[0...239]
CBExx name of station actual / CBExx name act
CU_S_AC_DP (CBE41
Can be changed: -
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
-
-
-
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
r8951[0...3]
CBExx IP address actual / CBExx IP addr act
CU_S_AC_DP (CBE41
Can be changed: -
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
0
255
-
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
Machine data and parameters
1722
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r8952[0...3]
CBExx default gateway actual / CBExx def GW act
CU_S_AC_DP (CBE41
Can be changed: -
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
0
255
-
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
r8953[0...3]
CBExx subnet mask actual / CBExx sub mask act
CU_S_AC_DP (CBE41
Can be changed: -
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
0
255
-
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
r8954
CBExx DHCP mode actual / CBExx DHCP act
CU_S_AC_DP (CBE41
Can be changed: -
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
0
3
-
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1723
SINAMICS parameters
3.2 SINAMICS parameters
r8955[0...5]
CBExx MAC address / CBExx MAC addr
CU_S_AC_DP (CBE41
Can be changed: -
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
0000 hex
00FF hex
-
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
r8956[0...1]
CBExx cyclic connection state / CBExx cyc con stat
CU_S_AC_DP (CBE41
Can be changed: -
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
0
13
-
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
r8957[0...5]
CBExx cyclic connection diagnostics / CBExx cyc con diag
CU_S_AC_DP (CBE41
Can be changed: -
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
-
-
-
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
Machine data and parameters
1724
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r8959
CBExx DAP ID / CBExx DAP ID
CU_S_AC_DP (CBE41
Can be changed: -
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
0000 hex
FFFF FFFF hex
-
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
r8960[0...3]
PN subslot controller assignment / PN subslot assign
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S_AC_PN,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
0
8
-
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
r8961[0...3]
PN IP Address Remote Controller 1 / IP addr rem ctrl1
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
-
r8961[0...3]
PN IP Address Remote Controller 1 / IP addr rem ctrl1
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S120_DP
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1725
SINAMICS parameters
3.2 SINAMICS parameters
r8962[0...3]
IP address remote controller 2 / IP addr rem ctrl2
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
-
r8962[0...3]
IP address remote controller 2 / IP addr rem ctrl2
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S120_DP
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
-
p8966[0...31]
CI: IF1 PZD extension PZD send word / PZD ext send word
CU_S_AC_DP (PZD ext),
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN (PZD ext),
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP (PZD ext),
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN (PZD ext)
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p8967[0...30]
CI: IF1 PZD extension PZD send double word / PZD ext send DW
CU_S_AC_DP (PZD ext),
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN (PZD ext),
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP (PZD ext),
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN (PZD ext)
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r8968
IF1 PZD extension PZD maximum interconnected / PZDext maxIntercon
CU_S_AC_DP (PZD ext),
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN (PZD ext),
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP (PZD ext),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN (PZD ext)
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
p8969
PROFIsafe wait for clock synchronization / PS wait sync
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
1726
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r8970[0...3]
CBExx subslot controller assignment / CBExx subslot
A_INF (PN CBE20),
Can be changed: -
Calculated: -
Access level: 3
B_INF (PN CBE20),
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S_AC_DP (CBE41
P-Group: -
Unit group: -
Unit selection: -
TSN), CU_S_AC_PN
(CBE41 TSN),
Not for motor type: -
Scaling: -
Expert list: 1
CU_S120_DP (CBE41
Min:
Max:
Factory setting:
TSN, CBE41 TSN,
0
8
-
CBE41 TSN, CBE41
TSN, PN CBE20, PN
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25), ENC (PN
CBE20), HLA (PN
CBE20), R_INF (PN
CBE20), S_INF (PN
CBE20), SERVO (PN
CBE20), SERVO_AC (PN
CBE20), TB30 (PN
CBE20), TM120 (PN
CBE20), TM15 (PN
CBE20), TM150 (PN
CBE20), TM15DI_DO
(PN CBE20), TM17 (PN
CBE20), TM31 (PN
CBE20), TM41 (PN
CBE20), VECTOR (PN
CBE20), VECTOR_AC
(PN CBE20)
r8971[0...3]
CBExx IP address remote controller 1 / CBExx IP rem ctrl1
CU_S_AC_DP (CBE41
Can be changed: -
Calculated: -
Access level: 3
TSN), CU_S_AC_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
(CBE41 TSN),
P-Group: -
Unit group: -
Unit selection: -
CU_S120_DP (CBE41
TSN, CBE41 TSN,
Not for motor type: -
Scaling: -
Expert list: 1
CBE41 TSN, CBE41
Min:
Max:
Factory setting:
TSN, PN CBE20, PN
0
255
-
CBE20, PN CBE20, PN
CBE20, PN CBE25, PN
CBE25, PN CBE25, PN
CBE25), CU_S120_PN
(CBE41 TSN, CBE41
TSN, CBE41 TSN,
CBE41 TSN, PN CBE20,
PN CBE20, PN CBE20,
PN CBE20, PN CBE25,
PN CBE25, PN CBE25,
PN CBE25)
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1727
|
||
|
|
|