SINAMICS parameters
3.2 SINAMICS parameters
r5321
Moment of inertia determination status word / J_determ ZSW
SERVO (J_estimator /
Can be changed: -
Calculated: -
Access level: 3
OBT), SERVO_AC
Data type: Unsigned32
Dynamic index: -
Function diagram: -
(J_estimator / OBT)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p5322[0...n]
Moment of inertia determination configuration / J_determ config
SERVO (J_estimator /
Can be changed: T, U
Calculated: -
Access level: 3
OBT), SERVO_AC
Data type: Unsigned32
Dynamic index: DDS, p0180 Function diagram: -
(J_estimator / OBT)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0001 bin
p5323[0...n]
Moment of inertia determination lower frequency limit / J_determ f_lim low
SERVO (J_estimator /
Can be changed: T, U
Calculated: -
Access level: 3
OBT), SERVO_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
(J_estimator / OBT)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Hz]
1000.0 [Hz]
0.0 [Hz]
p5324[0...n]
Moment of inertia determination upper frequency limit / J_determ f_lim up
SERVO (J_estimator /
Can be changed: T, U
Calculated: -
Access level: 3
OBT), SERVO_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
(J_estimator / OBT)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Hz]
1000.0 [Hz]
0.0 [Hz]
r5325
High load inertia identified / High load inert id
SERVO (J_estimator /
Can be changed: -
Calculated: -
Access level: 3
OBT, Lin), SERVO_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(J_estimator / OBT, Lin)
P-Group: Motor identification
Unit group: 27_1
Unit selection: p0100
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kg]
- [kg]
- [kg]
r5325
Moment of inertia identified / J_ident
SERVO (J_estimator /
Can be changed: -
Calculated: -
Access level: 3
OBT), SERVO_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(J_estimator / OBT)
P-Group: Motor identification
Unit group: 25_1
Unit selection: p0100
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kgm²]
- [kgm²]
- [kgm²]
Machine data and parameters
1590
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p5340[0...n]
Cogging torque compensation load-dependent amplitude linear / CTC loadDep amp x
SERVO
Can be changed: T, U
Calculated: -
Access level: 4
(Cog_M_comp),
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
SERVO_AC
P-Group: -
Unit group: -
Unit selection: -
(Cog_M_comp)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20000.000
20000.000
0.000
p5341[0...n]
Cogging torque compensation load-dependent amplitude quadratic / CTC loadDep amp x2
SERVO
Can be changed: T, U
Calculated: -
Access level: 4
(Cog_M_comp),
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
SERVO_AC
P-Group: -
Unit group: -
Unit selection: -
(Cog_M_comp)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
20000.000
0.000
p5342[0...n]
Cogging torque compensation load-dependent phase positive / CTC loadDep ph pos
SERVO
Can be changed: T, U
Calculated: -
Access level: 4
(Cog_M_comp),
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
SERVO_AC
P-Group: -
Unit group: -
Unit selection: -
(Cog_M_comp)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-180.000 [°]
180.000 [°]
0.000 [°]
p5343[0...n]
Cogging torque compensation load-dependent phase negative / CTC loadDep ph neg
SERVO
Can be changed: T, U
Calculated: -
Access level: 4
(Cog_M_comp),
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
SERVO_AC
P-Group: -
Unit group: -
Unit selection: -
(Cog_M_comp)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-180.000 [°]
180.000 [°]
0.000 [°]
p5344[0...n]
Cogging torque compensation load-dependent phase linear / CTC loadDep ph lin
SERVO
Can be changed: T, U
Calculated: -
Access level: 4
(Cog_M_comp),
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
SERVO_AC
P-Group: -
Unit group: -
Unit selection: -
(Cog_M_comp)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-360.000 [°]
360.000 [°]
0.000 [°]
p5345[0...n]
Cogging torque compensation load-dependent shutdown velocity / CTC loadDep shutd
SERVO (Cog_M_comp,
Can be changed: T, U
Calculated: -
Access level: 4
Lin), SERVO_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
(Cog_M_comp, Lin)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [m/min]
2000.0 [m/min]
200.0 [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1591
SINAMICS parameters
3.2 SINAMICS parameters
p5345[0...n]
Cogging torque compensation load-dependent shutdown speed / CTC loadDep shutd
SERVO
Can be changed: T, U
Calculated: -
Access level: 4
(Cog_M_comp),
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
SERVO_AC
P-Group: -
Unit group: -
Unit selection: -
(Cog_M_comp)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [rpm]
210000.0 [rpm]
1500.0 [rpm]
p5346[0...6]
Cogging torque compensation serial numbers after learning / CTC ser_noAftLearn
SERVO
Can be changed: T, U
Calculated: -
Access level: 4
(Cog_M_comp),
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC
P-Group: -
Unit group: -
Unit selection: -
(Cog_M_comp)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p5350[0...n]
Mot_temp_mod 1/3 boost factor at standstill / Standst boost_fact
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8017
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.0000
2.0000
2.0000
p5350[0...n]
Mot_temp_mod 1/3 boost factor at standstill / Standst boost_fact
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8017
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.0000
2.0000
2.0000
p5351[0...n]
Mot_temp_mod 3 stator power loss offset / Stat P_loss_offs
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 14_2
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [W]
100000 [W]
10000 [W]
p5352[0...n]
Mot_temp_mod 3 stator power loss linear n-dependent / Stat P_loss lin n
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 14_14
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100000.0000 [W min/1000]
100000.0000 [W min/1000]
10000.0000 [W min/1000]
Machine data and parameters
1592
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p5353[0...n]
Mot_temp_mod 3 stator power loss square law n-dependent / Stat P_loss sq n
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 14_16
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100000.0000 [W min²/1000²]
100000.0000 [W min²/1000²]
10000.0000 [W min²/1000²]
p5354[0...n]
Mot_temp_mod 3 stator power loss stator linear n-dependent / Stat P_loss lin l
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 14_13
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100000.0000 [W/A]
100000.0000 [W/A]
10000.0000 [W/A]
p5355[0...n]
Mot_temp_mod 3 stator power loss stator square law n-dependent / Stat P_loss sq l
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 14_15
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100000.0000 [W/A²]
100000.0000 [W/A²]
10000.0000 [W/A²]
p5370[0...n]
Mot_temp_mod 3 stator thermal capacity / Stat therm cap
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 47_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [kW sec/K]
10000.000 [kW sec/K]
0.001 [kW sec/K]
p5371[0...n]
Mot_temp_mod 3 stator winding thermal capacity / Stat_windTherm cap
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 47_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [kW sec/K]
10000.000 [kW sec/K]
0.001 [kW sec/K]
p5372[0...n]
Mot_temp_mod 3 rotor thermal capacity / Rot therm capacity
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 47_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [kW sec/K]
10000.000 [kW sec/K]
0.001 [kW sec/K]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1593
SINAMICS parameters
3.2 SINAMICS parameters
p5380[0...n]
Mot_temp_mod 3 stator/ambient thermal conductivity (standstill) / Stat/amb ThermCond
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 48_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [W/K]
10000.00000 [W/K]
0.00100 [W/K]
p5381[0...n]
Mot_temp_mod 3 stator/stator winding therm. conduct. coefficient / StatWind thm cond
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 48_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001 [W/K]
10000.000 [W/K]
1000.000 [W/K]
p5382[0...n]
Mot_temp_mod 3 stator/rotor coefficient of thermal conductivity / StatRot therm cond
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 48_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001 [W/K]
10000.000 [W/K]
1000.000 [W/K]
p5383[0...n]
Mot_temp_mod 3 stator/surrounding therm. cond. coeff. lin. n-dep / StatSurr lin n
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 48_2
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10000.0000 [W min/(1000 K)]
10000.0000 [W min/(1000 K)] 0.0000 [W min/(1000 K)]
p5384[0...n]
Mot_temp_mod 3 stator/surrounding therm cond. coeff sq-law n-dep / StatSurr sq n
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 48_3
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10000.0000 [W min²/(1000² K)]
10000.0000 [W min²/(1000²
0.0000 [W min²/(1000² K)]
K)]
r5386[0...4]
CO: Mot_temp remaining time until fault / t_remain to fault
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [s]
- [s]
- [s]
Machine data and parameters
1594
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r5387[0...n]
Mot_temp_mod 3 timer / Mod 3 timer
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8019
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [s]
- [s]
- [s]
p5388
BI: Mot_temp current reduction inhibit signal source / I_red inhib s_s
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 8016
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r5389.0...8
CO/BO: Mot_temp status word faults/alarms / Mot_temp ZSW F/A
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: 8015
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p5390[0...n]
Mot_temp_mod 1/3 alarm threshold / A thr
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8017
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [°C]
200.0 [°C]
110.0 [°C]
p5391[0...n]
Mot_temp_mod 1/3 fault threshold / F thr
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8017
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [°C]
200.0 [°C]
120.0 [°C]
r5392[0...2]
Mot_temp_mod 2 thermal resistance adaptation / Temp_mod 2 R adpt
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 50_1
Unit selection: p0100
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [K/W]
- [K/W]
- [K/W]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1595
SINAMICS parameters
3.2 SINAMICS parameters
r5393[0...2]
Mot_temp_mod 3 thermal conductivity adaptation / Temp_mod 3 L adpt
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 48_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [W/K]
- [W/K]
- [W/K]
p5394[0...n]
Mot_temp sensor configuration / Sensor config
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF hex
0000 hex
r5395[0...7]
Mot_temp_mod 2/3 power losses calculated / Temp_mod 2/3 Pcalc
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 14_6
Unit selection: p0100
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r5396[0...n]
CO: Encoder temperature / Encoder temp
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r5397
Mot_temp_mod 1/3 ambient temperature image p0613 / AmbTmp image p613
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8019
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r5398[0...n]
Mot_temp_mod 1/3 alarm threshold image p5390 / A thr image p5390
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8019
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
Machine data and parameters
1596
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r5399[0...n]
Mot_temp_mod 1/3 fault threshold image p5391 / F thr image p5391
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8019
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
p5400
Grid droop control configuration / Grid drp ctrl cfg
A_INF (Line droop ctrl),
Can be changed: T
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p5401[0...1]
BI: Line droop control activation / Ldrp act
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 7982, 7986,
7988
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 0
[1] 1
r5402.0...6
CO/BO: Line droop control status word / Ldrp ZSW
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p5403[0...1]
CI: Line droop control current signal source / Ldrp I s_s
A_INF (Line droop ctrl),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 3467[0]
[1] 3467[1]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1597
SINAMICS parameters
3.2 SINAMICS parameters
p5404[0...1]
CI: Line droop control voltage signal source / Ldrp U s_s
A_INF (Line droop ctrl),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 3468[0]
[1] 3468[1]
p5405
Line droop control frequency droop no-load frequency / Ldrp f_no-ld
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
30.00 [%]
300.00 [%]
100.00 [%]
p5406[0...1]
CI: Line droop control frequency droop supplementary setpoint / Ldrp f_suppl_set
A_INF (Line droop ctrl,
Can be changed: T, U
Calculated: -
Access level: 3
Line transf), R_INF
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7982
(Line droop ctrl, Line
P-Group: Closed-loop control
Unit group: -
Unit selection: -
transf)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 0
[1] 5582[0]
p5407
Line droop control frequency droop gradient / Ldrp f grad
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
100.00 [%]
5.00 [%]
p5408
CI: Line droop control frequency droop gradient dynamic / Ldrp f grad dy
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1598
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p5409
Line droop control frequency droop smoothing time / Ldrp f t_smth
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
10000.00 [ms]
150.00 [ms]
r5410
CO: Line droop control frequency droop output / Ldrp f outp
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
r5411[0...1]
CO: Line droop control frequency droop active power / Ldrp f P_act
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r5412
CO: Line droop control line angle / Ldrp angle
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2005
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
p5413
Line droop control additional frequency droop gradient / Ldrp add-f
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
10000.0 [%]
0.0 [%]
p5414
Line droop control additional frequency droop smoothing time / Ldrp add-t
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
100.0 [%]
10.0 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1599
SINAMICS parameters
3.2 SINAMICS parameters
p5415
Line droop control voltage droop no-load voltage / Ldrp U_no-ld
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
30.00 [%]
300.00 [%]
100.00 [%]
p5416[0...1]
CI: Line droop control voltage droop supplementary setpoint / Ldrp U_suppl_set
A_INF (Line droop ctrl,
Can be changed: T, U
Calculated: -
Access level: 3
Line transf), R_INF
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7982
(Line droop ctrl, Line
P-Group: Closed-loop control
Unit group: -
Unit selection: -
transf)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 0
[1] 5582[1]
p5417
Line droop control voltage droop gradient / Ldrp U grad
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
100.00 [%]
5.00 [%]
p5418
CI: Line droop control voltage droop gradient dynamic / Ldrp U grad dy
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p5419
Line droop control voltage droop smoothing time / Ldrp U t_smth
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
10000.00 [ms]
150.00 [ms]
r5420
CO: Line droop control voltage droop output / Ldrp U outp
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
Machine data and parameters
1600
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r5421[0...1]
CO: Line droop control voltage droop reactive current / Ldrp U I_react
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r5422[0...1]
CO: Line droop control voltage droop reactive power / Ldrp U Q_react
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 14_12
Unit selection: p0505
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kvar]
- [kvar]
- [kvar]
p5423
Line droop control supplementary inductance / Ldrp L_suppl
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7983
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10.000 [mH]
10.000 [mH]
0.000 [mH]
p5424
Line droop control supplementary inductance smoothing time / Ldrp L_suppl t_sm
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7983
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
100.00 [ms]
0.00 [ms]
p5425[0...1]
CI: Line droop control voltage control signal source / Ldrp U_ctrl s_s
A_INF (Line droop ctrl),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 3468[0]
[1] 3468[1]
p5426
Line droop control voltage control P gain / Ldrp U_ctrl Kp
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
100.0 [%]
0.0 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1601
SINAMICS parameters
3.2 SINAMICS parameters
p5427
Line droop control voltage control integration time / Ldrp U_ctrl Ti
A_INF (Line droop ctrl,
Can be changed: T, U
Calculated: -
Access level: 3
Line transf, Line
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
transf), R_INF (Line
P-Group: Closed-loop control
Unit group: -
Unit selection: -
droop ctrl, Line transf,
Line transf)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
10000.0 [ms]
500.0 [ms]
p5428[0...3]
Line droop control voltage control short circuit / Ldrp U_ctrl sh
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
100.00 [%]
[0] 20.00 [%]
[1] 0.00 [%]
[2] 90.00 [%]
[3] 2.00 [%]
r5429
CO: Line droop control voltage control output / Ldrp U_ctrl outp
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
p5430[0...1]
Modulation depth controller setting / ModDpth_ctrl set
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7983, 7984
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.0 [%]
110.0 [%]
[0] 94.0 [%]
[1] 110.0 [%]
p5431
Modulation depth controller dynamic response / Mod_ctrl dyn
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
10000.0 [ms]
10.0 [ms]
Machine data and parameters
1602
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p5432[0...1]
Modulation depth controller output voltage limits / Mod_ctrl lim U
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7984
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-200.0 [V]
200.0 [V]
[0] 100.0 [V]
[1] -100.0 [V]
r5433
CO: Modulation depth controller output / Mod_ctrl outp
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p5434
Direct component controller low pass limit frequency / I_dc_reg PT2 f
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7983
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [Hz]
1.000 [Hz]
0.500 [Hz]
p5435
Direct component controller low pass damping / I_dc_reg PT2 D
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7983
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001
10.000
1.000
p5436
Direct component controller P gain / I_dc_reg Kp
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7983
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0000 [ohm]
10.0000 [ohm]
0.0200 [ohm]
p5437
Direct component controller integration time / I_dc_reg Ti
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7983
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
100.000 [s]
3.500 [s]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1603
SINAMICS parameters
3.2 SINAMICS parameters
p5438
Direct component controller limiting / I_dc_ctrl limit
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7983
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
10.0 [%]
2.0 [%]
p5440
Harmonics controller bandpass filter activation / Harmonic bandp act
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: Unsigned16
Dynamic index: -
Function diagram: 7983
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p5441[0...3]
Harmonics controller bandpass filter gain / Bandpass gain
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7983
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
10000.00
120.00
p5442[0...3]
Harmonics controller bandpass filter mid-frequency / Bandpass f_mid
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7983
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
1000.00 [Hz]
300.00 [Hz]
p5443
Harmonics controller bandpass filter gain total / Bandpass gain tot
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7983
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
1.00
r5444[0...1]
CO: Line droop control line voltage absolute value / U_line AbsV
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
Machine data and parameters
1604
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r5445[0...11]
Line droop control voltage alpha/beta component / U A/B comp
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982, 7983
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r5446[0...1]
CO: Line droop control line voltage active/reactive component / U_line P/Q comp
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r5447
CO: Line droop control line voltage absolute value / I_line AbsV
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r5448[0...3]
Line droop control line current alpha/beta component / I_line A/B comp
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982, 7983
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r5449[0...1]
CO: Line droop control line current active/reactive component / I_line P/Q comp
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r5450[0...5]
CO: Line droop control setpoint active / Ldrp set act
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1605
SINAMICS parameters
3.2 SINAMICS parameters
p5451
BI: Current hysteresis controller operating mode / I_hyst_ctrl mode
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r5452.0...3
CO/BO: Current hysteresis controller sequence control status word / I_hyst_ctrl seqZSW
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p5453[0...5]
Current hysteresis controller overcurrent limit / I_hyst_ctrl I lim
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
45.0 [%]
130.0 [%]
[0...4] 85.0 [%]
[5] 115.0 [%]
p5454[0...5]
Current hysteresis controller overcurrent hysteresis width / I_hyst_ctrl I hyst
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
15.0 [%]
50.0 [%]
20.0 [%]
p5455[0...5]
Current hysteresis controller overcurrent tolerance range / I_hyst_ctrl I tol
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
100.0 [%]
20.0 [%]
Machine data and parameters
1606
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p5456[0...2]
Current hysteresis controller configuration / I_hyst_ctrl config
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 1000 0000 0010 0000 bin
[1] 1000 0000 0010 0000 bin
[2] 1000 0000 0011 0000 bin
p5457[0...2]
Current hysteresis controller pulse frequency changeover / I_hyst_ctrl f_puls
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.0 [%]
200.0 [%]
100.0 [%]
p5458[0...1]
Current hysteresis controller minimum time operating state / I_hyst_ctrl t mode
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
3.000 [s]
[0] 1.000 [s]
[1] 1.000 [s]
p5459[0...3]
Current hysteresis controller sequence control state change / I_hyst_ctrl seq
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7986
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
200.0 [%]
[0] 10.0 [%]
[1] 5.0 [%]
[2] 70.0 [%]
[3] 75.0 [%]
p5460[0...n]
VSM2/3 input line supply voltage, voltage divider / VSM2/3 inp U_divid
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
100000.00 [%]
0.00 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1607
SINAMICS parameters
3.2 SINAMICS parameters
r5461[0...n]
CO: VSM2 input line supply voltage u1 - u2 / VSM2 inp u1-u2
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: 5_3
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r5462[0...n]
CO: VSM2 input line supply voltage u2 - u3 / VSM2 inp u2-u3
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: 5_3
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r5464[0...n]
CO: VSM2 temperature evaluation status / VSM2 temp status
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: Unsigned16
Dynamic index: p0150
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p5465[0...n]
VSM2 temperature evaluation sensor type / VSM2 temp sens_typ
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: Integer16
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
0
r5466[0...n]
CO: VSM2 temperature actual value / VSM2 temp_ActV
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
p5467[0...n]
VSM2 overtemperature alarm threshold / VSM2 temp A_thr
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: -
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
-100.00 [°C]
301.00 [°C]
150.00 [°C]
Machine data and parameters
1608
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p5468[0...n]
VSM2 overtemperature shutdown threshold / VSM2 temp F_thr
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: -
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
-100.00 [°C]
301.00 [°C]
180.00 [°C]
p5469[0...n]
VSM2 overtemperature hysteresis / VSM2 temp hyst
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: -
Unit group: 21_2
Unit selection: p0505
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
1.00 [K]
50.00 [K]
3.00 [K]
p5470[0...n]
VSM2 10 V input CT gain / VSM2 CT_gain
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
0.000 [A]
1000.000 [A]
1.000 [A]
r5471[0...n]
CO: VSM2 10 V input CT 1 actual value / VSM2 CT1 I_ActV
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r5472[0...n]
CO: VSM2 10 V input CT 2 actual value / VSM2 CT2 I_ActV
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r5473[0...n]
CO: VSM2 10 V input 1 actual value / VSM2 inp 1 U_ActV
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1609
SINAMICS parameters
3.2 SINAMICS parameters
r5474[0...n]
CO: VSM2 10 V input 2 actual value / VSM2 inp 2 U_ActV
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p5476
Line droop control damping gain / Line droop damp k
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
1000.0 [%]
0.0 [%]
p5477
Line droop control damping smoothing time / Line droop damp T
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7982
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
5.0 [%]
2000.0 [%]
200.0 [%]
p5478[0...1]
Line droop control current limits / Line droop I_lim
A_INF (Line droop ctrl)
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.0 [%]
123.0 [%]
[0] 90.0 [%]
[1] 123.0 [%]
p5478[0...1]
Line droop control current limits / Line droop I_lim
R_INF (Line droop ctrl)
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.0 [%]
123.0 [%]
[0] 67.0 [%]
[1] 67.0 [%]
Machine data and parameters
1610
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r5479[0...5]
Line droop control current permissible / Line droop I perm
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
p5480
Transformer magnetization mode / Tr mag mode
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: Integer16
Dynamic index: -
Function diagram: 7990
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
102
0
p5481[0...2]
Transformer magnetization times / Tr mag t
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7988, 7993,
7994
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.04 [s]
100.00 [s]
[0] 2.00 [s]
[1] 1.00 [s]
[2] 1.00 [s]
r5482
CO: Line synchronization status / Line sync status
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: Integer16
Dynamic index: -
Function diagram: 7988, 7989,
7994
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
207
-
p5483
BI: Line circuit breaker enable / Line LSS enab
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 7988, 7990,
7994
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1611
SINAMICS parameters
3.2 SINAMICS parameters
p5484[0...2]
Magnetization transformer controller dynamics / Mag tr ctrl_dyn
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7993
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
1000.00 [ms]
[0] 50.00 [ms]
[1] 50.00 [ms]
[2] 100.00 [ms]
p5485[0...1]
Transformer magnetization voltage thresholds / Tr mag U_thr
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7993
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [V]
300.0 [V]
[0] 35.0 [V]
[1] 3.5 [V]
p5486[0...1]
Transformer rated voltage primary / Tr U_rated pri
A_INF (Line transf),
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7990
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Vrms]
63000.00 [Vrms]
400.00 [Vrms]
p5487[0...3]
CI: Transformer primary voltage signal source / Transf U_pri s_s
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7990
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 5461[0]
[1] 5462[0]
[2] 0
[3] 0
r5488[0...5]
CO: Transformer secondary voltage transformed / Tr U_sec trans
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7990
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
Machine data and parameters
1612
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r5489
Transformer leakage inductance identified / Tr L_leak ident
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
p5490
Transformer leakage inductance / Tr L_leak
A_INF (Line transf),
Can be changed: C2(1), T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7990
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001 [mH]
1000.000 [mH]
0.100 [mH]
r5491
Transformer magnetizing inductance identified / Tr L_H ident
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
p5492
Transformer magnetizing inductance / Tr L_H
A_INF (Line transf),
Can be changed: C2(1), T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7990
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.10 [mH]
10000.00 [mH]
250.00 [mH]
r5493.0...1
CO/BO: Line circuit breaker control signals / LSS control sig
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: Unsigned16
Dynamic index: -
Function diagram: 7990
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p5494[0...1]
Transformer magnetization scaling values / Tr mag scal
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7993
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
150.0 [%]
[0] 100.0 [%]
[1] 40.0 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1613
SINAMICS parameters
3.2 SINAMICS parameters
p5495
Transformer operating mode configuration / Tr op config
A_INF (Line transf),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line transf)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
r5497[0...1]
CO: Transformer secondary current / Tr I_second
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r5498[0...2]
CO: Transformer secondary voltage / Tr U_second
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7990
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r5499.0...6
CO/BO: Line synchronization status word / Sync status word
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p5500
Dynamic grid support configuration / Dyn grid config
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: Unsigned16
Dynamic index: -
Function diagram: 7996, 7997,
grid support)
7998
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 1000 1000 bin
p5501
BI: Dynamic grid support activation / Dyn grid act
A_INF (Dyn. grid
Can be changed: T, U
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
grid support)
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1614
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r5502.0...4
CO/BO: Dynamic grid support status word / Dyn grid ZSW
A_INF (Dyn. grid
Can be changed: -
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: Unsigned16
Dynamic index: -
Function diagram: 7998
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p5503[0...1]
CI: Dynamic grid support current signal source / Dyn grid I s_s
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 3467[0]
[1] 3467[1]
p5504[0...1]
CI: Dynamic grid control voltage signal source / Dyn grid U s_s
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7996, 7999
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 3468[0]
[1] 3468[1]
p5505[0...3]
Dynamic grid support characteristic voltage values / Dyn grid char U
A_INF (Dyn. grid
Can be changed: T, U
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7996, 7998
grid support)
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
100.0 [%]
[0] 10.0 [%]
[1] 50.0 [%]
[2] 10.0 [%]
[3] 50.0 [%]
p5506[0...3]
Dynamic grid support characteristic reactive current setpoint / Dyn grid char I
A_INF (Dyn. grid
Can be changed: T, U
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7996, 7997
grid support)
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
500.0 [%]
[0] 20.0 [%]
[1] 100.0 [%]
[2] 20.0 [%]
[3] 100.0 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1615
SINAMICS parameters
3.2 SINAMICS parameters
p5507[0...4]
Dynamic grid support times / Dyn grid times
A_INF (Dyn. grid
Can be changed: T, U
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7996, 7998,
grid support)
7999
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
10000.00 [ms]
[0] 500.00 [ms]
[1] 2.00 [ms]
[2] 20.00 [ms]
[3] 4.00 [ms]
[4] 8.00 [ms]
p5508[0...1]
Dynamic grid support Vdc thresholds / Dyn grid Vdc thr
A_INF (Dyn. grid
Can be changed: T, U
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7997
grid support)
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-200 [V]
0 [V]
[0] -50 [V]
[1] 0 [V]
p5509[0...14]
Dynamic grid support scaling values / Dyn grid scal
A_INF (Dyn. grid
Can be changed: T, U
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7996, 7997,
grid support)
7998
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.10 [%]
200.00 [%]
[0] 40.00 [%]
[1] 40.00 [%]
[2] 4.00 [%]
[3] 1.00 [%]
[4] 100.00 [%]
[5] 100.00 [%]
[6] 1.00 [%]
[7] 0.10 [%]
[8] 0.10 [%]
[9] 10.00 [%]
[10] 5.00 [%]
[11] 100.00 [%]
[12] 100.00 [%]
[13] 3.00 [%]
[14] 105.00 [%]
Machine data and parameters
1616
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r5510[0...8]
CO: Dynamic grid support output / Dyn grid outp
A_INF (Dyn. grid
Can be changed: -
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7987, 7997
grid support)
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r5511[0...1]
CO: Dynamic grid support line voltage amplitude / Dyn grid U ampl
A_INF (Dyn. grid
Can be changed: -
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7996
grid support)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r5512[0...1]
CO: Dynamic grid support line voltage absolute value / Dyn grid U AbsV
A_INF (Dyn. grid
Can be changed: -
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7996, 7999
grid support)
P-Group: -
Unit group: 5_1
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
r5513[0...3]
CO: Dynamic grid support line voltage pos/neg phase-sequence system / Dyn grid U
pos/neg
A_INF (Dyn. grid
Can be changed: -
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7996
grid support)
P-Group: -
Unit group: 5_1
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
r5514[0...1]
CO: Dynamic grid support current setpoint alpha/beta / Dyn grid I a/b
A_INF (Dyn. grid
Can be changed: -
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7997
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r5515[0...1]
CO: Dynamic grid support active power display / Dyn grid P disp
A_INF (Dyn. grid
Can be changed: -
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
grid support)
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1617
SINAMICS parameters
3.2 SINAMICS parameters
r5516[0...1]
CO: Dynamic grid support reactive power display / Dyn grid Q disp
A_INF (Dyn. grid
Can be changed: -
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
grid support)
P-Group: Displays, signals
Unit group: 14_12
Unit selection: p0505
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kvar]
- [kvar]
- [kvar]
p5518
CI: Dynamic grid support line phase angle signal source / Dyn grid ang s_s
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2005
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p5519
CI: Dynamic grid support line frequency signal source / Line freq s_s
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p5520
CI: Dynamic grid support FRT current limit signal source / FRT curr lim s_s
A_INF (Dyn. grid
Can be changed: T, U
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7997
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
r5522.0...3
CO/BO: Dynamic grid support sequence control status word / Dyn grid seq ZSW
A_INF (Dyn. grid
Can be changed: -
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: Unsigned16
Dynamic index: -
Function diagram: -
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1618
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p5523[0...2]
Dynamic grid support overcurrent limit / Dyn grid I lim
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
grid support)
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.0 [%]
130.0 [%]
[0] 120.0 [%]
[1] 120.0 [%]
[2] 120.0 [%]
p5524[0...2]
Dynamic grid support hysteresis width / Dyn grid hyst
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
grid support)
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
15.0 [%]
50.0 [%]
20.0 [%]
p5525[0...2]
Dynamic grid support overcurrent tolerance range / Dyn grid I tol
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
grid support)
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
100.0 [%]
20.0 [%]
p5526[0...2]
Dynamic grid support overcurrent modulator configuration / Dyn grid I config
A_INF (Dyn. grid
Can be changed: T, U
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: Unsigned16
Dynamic index: -
Function diagram: -
grid support)
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 1000 0000 1010 0000 bin
[1] 1000 0000 1010 0000 bin
[2] 1000 0000 1011 0000 bin
p5527[0...2]
Dynamic grid support changeover pulse frequency / Dyn grid chg f_pul
A_INF (Dyn. grid
Can be changed: T, U
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.0 [%]
200.0 [%]
[0] 100.0 [%]
[1] 100.0 [%]
[2] 100.0 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1619
SINAMICS parameters
3.2 SINAMICS parameters
p5528[0...4]
Dynamic grid control operating state times / Dyn grid t state
A_INF (Dyn. grid
Can be changed: T, U
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7998
grid support)
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
10.000 [s]
[0] 1.000 [s]
[1] 2.000 [s]
[2] 0.300 [s]
[3] 0.050 [s]
[4] 0.050 [s]
p5529[0...7]
Dynamic grid support sequence control scaling values / Dyn grid seq scal
A_INF (Dyn. grid
Can be changed: T, U
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7998
grid support)
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
200.0 [%]
[0] 10.0 [%]
[1] 5.0 [%]
[2] 65.0 [%]
[3] 70.0 [%]
[4] 15.0 [%]
[5] 15.0 [%]
[6] 100.0 [%]
[7] 105.0 [%]
p5540
Line monitoring configuration / Line mon config
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: Unsigned16
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0110 0000 0011 bin
p5541
BI: Line monitoring activation / Line mon act
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1620
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r5542.0...14
CO/BO: Line monitoring status word / Line mon ZSW
A_INF (Dyn. grid
Can be changed: -
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: Unsigned16
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p5543[0...3]
Line monitoring voltage threshold / Line mon U_thr
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.0 [%]
150.0 [%]
[0] 110.0 [%]
[1] 88.0 [%]
[2] 100.0 [%]
[3] 100.0 [%]
p5544[0...3]
Line monitoring frequency threshold / Line mon_f thr
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Hz]
5.0 [Hz]
[0] 0.5 [Hz]
[1] 0.7 [Hz]
[2] 0.0 [Hz]
[3] 0.0 [Hz]
p5545[0...7]
Line monitoring times / Line mon times
A_INF (Dyn. grid
Can be changed: T, U
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
300000.00 [ms]
[0] 150.00 [ms]
[1] 50.00 [ms]
[2] 3000.00 [ms]
[3] 0.00 [ms]
[4] 0.00 [ms]
[5] 2000.00 [ms]
[6] 100.00 [ms]
[7] 60000.00 [ms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1621
SINAMICS parameters
3.2 SINAMICS parameters
p5547[0]
Line monitoring frequencies / Line mon f
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.01 [Hz]
1.00 [Hz]
0.10 [Hz]
p5548[0]
Line monitoring gains / Line mon gains
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 4
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10.00
10.00
0.10
p5550[0...2]
Line monitoring line fault thresholds voltage characteristic / Line mon U_thr
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
150.0 [%]
[0] 120.0 [%]
[1] 80.0 [%]
[2] 5.0 [%]
p5551[0...9]
Line monitoring HVRT time values / Line mon HVRT t
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [s]
1000.00 [s]
[0] 0.00 [s]
[1] 0.15 [s]
[2] 0.70 [s]
[3] 1.50 [s]
[4] 3.00 [s]
[5] 25.00 [s]
[6] 50.00 [s]
[7] 100.00 [s]
[8] 200.00 [s]
[9] 300.00 [s]
Machine data and parameters
1622
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p5552[0...9]
Line monitoring HVRT voltage values / Line mon HVRT U
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
101.0 [%]
150.0 [%]
110.0 [%]
p5553[0...9]
Line monitoring LVRT time values / Line mon LVRT t
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [s]
300.00 [s]
[0] 0.00 [s]
[1] 0.15 [s]
[2] 0.70 [s]
[3] 1.50 [s]
[4] 3.00 [s]
[5] 25.00 [s]
[6] 50.00 [s]
[7] 100.00 [s]
[8] 200.00 [s]
[9] 300.00 [s]
p5554[0...9]
Line monitoring LVRT voltage values / Line mon LVRT U
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
99.0 [%]
90.0 [%]
p5555[0...2]
Line monitoring line fault thresholds frequency characteristic / Line mon thr f
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.0 [Hz]
20.0 [Hz]
[0] 0.5 [Hz]
[1] -0.7 [Hz]
[2] 0.2 [Hz]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1623
SINAMICS parameters
3.2 SINAMICS parameters
p5556[0...9]
Line monitoring HFRT time values / Line mon HFRT t
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [s]
1000.00 [s]
[0] 0.00 [s]
[1] 0.15 [s]
[2] 0.70 [s]
[3] 1.50 [s]
[4] 3.00 [s]
[5] 25.00 [s]
[6] 50.00 [s]
[7] 100.00 [s]
[8] 200.00 [s]
[9] 300.00 [s]
p5557[0...9]
Line monitoring HFRT frequency values / Line mon HFRT f
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Hz]
20.0 [Hz]
1.5 [Hz]
p5558[0...9]
Line monitoring LFRT time values / Line mon LFRT t
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [s]
300.00 [s]
[0] 0.00 [s]
[1] 0.15 [s]
[2] 0.70 [s]
[3] 1.50 [s]
[4] 3.00 [s]
[5] 25.00 [s]
[6] 50.00 [s]
[7] 100.00 [s]
[8] 200.00 [s]
[9] 300.00 [s]
p5559[0...9]
Line monitoring LFRT frequency values / Line mon LFRT f
A_INF (Dyn. grid
Can be changed: T
Calculated: -
Access level: 3
support), R_INF (Dyn.
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7999
grid support)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.0 [Hz]
0.0 [Hz]
-2.5 [Hz]
Machine data and parameters
1624
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p5571
BI: Line PLL2 activation signal source / Line PLL2 act s_s
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 7992
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
5499.5
r5572.0...3
CO/BO: Line PLL2 status word / Line PLL2 status
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p5574[0...1]
CI: Line PLL2 voltage signal source / Line PLL2 U s_s
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7992
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 0
[1] 0
p5580
Island grid black start mode / Black start mode
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: Integer16
Dynamic index: -
Function diagram: 7988
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
p5581[0...8]
Island grid times / Island grid t
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7988, 7989
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.10 [s]
100.00 [s]
[0] 2.00 [s]
[1] 1.00 [s]
[2] 60.00 [s]
[3] 1.00 [s]
[4] 0.10 [s]
[5] 1.00 [s]
[6] 60.00 [s]
[7] 1.00 [s]
[8] 0.10 [s]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1625
SINAMICS parameters
3.2 SINAMICS parameters
r5582[0...1]
CO: Island grid synchronization setpoint control / Island sync set
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7995
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p5583[0...2]
BI: Island grid synchronization signal sources / Island sync s_s
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 7989, 7990
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 0
[1] 0
[2] 0
p5584[0...2]
Island grid synchronization controller dynamics / Island sync dyn
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7995
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
1000.00 [ms]
[0] 100.00 [ms]
[1] 100.00 [ms]
[2] 100.00 [ms]
p5585[0...1]
Island grid synchronization voltage thresholds / Island sync U_thr
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7995
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [V]
300.0 [V]
[0] 35.0 [V]
[1] 3.5 [V]
Machine data and parameters
1626
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p5586[0...6]
Island grid scaling values / Island scal_val
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7988, 7989,
7995
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.1 [%]
200.0 [%]
[0] 3.0 [%]
[1] 0.5 [%]
[2] 1.0 [%]
[3] 1.0 [%]
[4] 4.0 [%]
[5] 0.4 [%]
[6] 2.0 [%]
p5588[0...2]
Grid droop control asymmetry times / Grid drp asym t
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
1000000.0 [ms]
0.0 [ms]
p5589
Grid droop control asymmetry angle / Grid drp asym a
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1.0 [°]
360.0 [°]
-1.0 [°]
p5590[0...8]
CI: Grid droop control asymmetry setpoint signal sources / Ldrp asym s_s
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 5594[0]
[1] 5594[1]
[2] 5594[2]
[3] 5594[3]
[4] 5594[4]
[5] 5594[5]
[6] 5594[6]
[7] 5594[7]
[8] 5594[8]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1627
SINAMICS parameters
3.2 SINAMICS parameters
p5591
BI: Grid droop control asymmetry activation / Grid_drp asym act
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r5592.0...5
CO/BO: Grid droop control asymmetry status word / Grid_drp asym ZSW
A_INF (Line droop ctrl),
Can be changed: -
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p5594[0...8]
CO: Grid droop control asymmetry fixed setpoints / Line drp asym fix
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
300.00 [%]
100.00 [%]
r5600
Pe energy-saving mode ID / Pe mode ID
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: 2381, 2382
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
-
p5601
Pe energy-saving mode properties / Pe mode properties
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p5602[0...1]
Pe energy-saving mode pause time minimal / Pe mod t_pause min
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: 2381
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
300000 [ms]
4294967295 [ms]
[0] 300000 [ms]
[1] 480000 [ms]
Machine data and parameters
1628
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r5603[0...1]
Pe energy-saving mode transition time / Pe mode t_trans
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
r5604[0...1]
Pe operating state transition time regular / Pe st t_trans reg
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
r5605[0...1]
Pe energy-saving mode time of minimum stay / Pe t_min stay
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
p5606[0...1]
Pe energy-saving mode time of maximum stay / Pe t_max_stay
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: 2381
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
4294967295 [ms]
4294967295 [ms]
r5607
Pe power usage / Pe P_use
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r5608
Pe energy usage energy-saving mode transition / Pe en mod trans
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kWh]
- [kWh]
- [kWh]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1629
SINAMICS parameters
3.2 SINAMICS parameters
r5609
Pe energy usage operating state transition / Pe en op trans
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kWh]
- [kWh]
- [kWh]
r5610
Pe energy usage during the transition / Pe en_use trans
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kWh]
- [kWh]
- [kWh]
p5611
Pe energy-saving properties general / Pe properties gen
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: 2381, 2382
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p5612[0...1]
Pe energy-saving properties mode-dependent / Pe properties mod
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 9
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
[0] 0110 bin
[1] 0000 bin
r5613.0...1
CO/BO: Pe energy-saving active/inactive / Pe save act/inact
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: 2382
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p5614
BI: Pe set switching on inhibited signal source / Pe sw-on_inh s_s
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 9
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2382
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1630
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r5615[0...1]
Pe operating state transition time actual / Pe st t_trans act
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
p6277[0...n]
Reverse field excitation speed setpoint rotat field inversion / RFE n_set revers
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: ASM, PMSM, REL, RESM
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-20000.00 [rpm]
20000.00 [rpm]
0.00 [rpm]
p6278[0...n]
Reverse field excit speed setp rotat field inversion hysteresis / n_inverse IE hyst
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-20000.00 [rpm]
20000.00 [rpm]
10.00 [rpm]
r6311[0...1]
CO: Line PLL2 frequency / Line PLL2 f
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p0514
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
r6313
CO: PLL VSM output voltage / PLL VSM U_outp
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 2
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 5_1
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
r6313
CO: Line PLL2 smoothed voltage / Line PLL2 U smth
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 2
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6799, 8026
P-Group: Displays, signals
Unit group: 5_1
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1631
SINAMICS parameters
3.2 SINAMICS parameters
r6314
CO: Line PLL2 phase angle / Line PLL2 ph_angle
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2005
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
r6316
CO: Line PLL2 line supply angle measured / Line PLL2 ang meas
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2005
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
p6397
Motor Module phase shift second system / MM ph_sh 2nd sys
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
8
0
p6420[0...1]
Phase shift input voltage VSM to the drive converter / INF U VSM/conv
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-180.00 [°]
179.90 [°]
0.00 [°]
p6421[0...1]
Line supply voltage sensing gain adaptation / U_line gain
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7990
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.000 [%]
200.000 [%]
100.000 [%]
p6422
Line supply voltage rotating field direction / U_line field dir
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
1632
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p6423
PLL dynamic / PLL dynamic
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 4
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
2.000 [%]
500.000 [%]
20.000 [%]
p6425
Line voltage active/react. power comp. smoothing time constant / U_line p/q Tc_smth
A_INF (Line transf),
Can be changed: T
Calculated: -
Access level: 4
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.000 [ms]
5000.000 [ms]
100.000 [ms]
r6440
Transf phase offset identified / Tr ph_shift ident
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 3
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
r6441
Transformer gain adaptation identified / Tr gain ident
A_INF (Line transf),
Can be changed: -
Calculated: -
Access level: 2
R_INF (Line transf)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p6700[0...n]
Voltage model angle smoothing / U_mod ang smth
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
100 [ms]
0 [ms]
p6870[0...n]
VSM offset voltage u1 - u2 / VSM offset u1 - u2
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100.000 [V]
100.000 [V]
0.000 [V]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1633
SINAMICS parameters
3.2 SINAMICS parameters
p6870[0...n]
VSM offset voltage u1 - u2 / VSM offset u1 - u2
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100.000 [V]
100.000 [V]
0.000 [V]
p6871[0...n]
VSM offset voltage u2 - u3 / VSM offset u2 - u3
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100.000 [V]
100.000 [V]
0.000 [V]
p6871[0...n]
VSM offset voltage u2 - u3 / VSM offset u2 - u3
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100.000 [V]
100.000 [V]
0.000 [V]
p6903[0...n]
Voltage actual values offset mode / U_ActV offs mode
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
1
p6903[0...n]
Voltage actual values offset mode / U_ActV offs mode
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Integer16
Dynamic index: p0150
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
1
r6991[0...4]
Recorder settings display / Rec setting disp
A_INF (Rec), B_INF
Can be changed: -
Calculated: -
Access level: 4
(Rec), R_INF (Rec),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8144
S_INF (Rec), SERVO
P-Group: -
Unit group: -
Unit selection: -
(Rec), SERVO_AC (Rec),
VECTOR (Rec),
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC (Rec)
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1634
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r6992.0...15
CO/BO: Recorder status word / Rec ZSW
A_INF (Rec), B_INF
Can be changed: -
Calculated: -
Access level: 4
(Rec), R_INF (Rec),
Data type: Unsigned16
Dynamic index: -
Function diagram: 8144, 8145
S_INF (Rec), SERVO
P-Group: Displays, signals
Unit group: -
Unit selection: -
(Rec), SERVO_AC (Rec),
VECTOR (Rec),
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC (Rec)
Min:
Max:
Factory setting:
-
-
-
p6993[0...2]
Recorder trigger 2 bit mask / Rec trig 2 mask
A_INF (Rec), B_INF
Can be changed: T, U
Calculated: -
Access level: 4
(Rec), R_INF (Rec),
Data type: Unsigned32
Dynamic index: -
Function diagram: 8144
S_INF (Rec), SERVO
P-Group: -
Unit group: -
Unit selection: -
(Rec), SERVO_AC (Rec),
VECTOR (Rec),
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC (Rec)
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0001 hex
p6994[0...2]
CI: Recorder trigger 2 signal source / Rec trig 2 s_s
A_INF (Rec), B_INF
Can be changed: T, U
Calculated: -
Access level: 4
(Rec), R_INF (Rec),
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 8144
S_INF (Rec), SERVO
P-Group: -
Unit group: -
Unit selection: -
(Rec), SERVO_AC (Rec),
VECTOR (Rec),
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC (Rec)
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1635
SINAMICS parameters
3.2 SINAMICS parameters
p6996[0...63]
Recorder signals / Rec sig
SERVO (Rec),
Can be changed: T, U
Calculated: -
Access level: 4
SERVO_AC (Rec),
Data type: Unsigned32
Dynamic index: -
Function diagram: 8144
VECTOR (Rec),
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR_AC (Rec)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
996553699
[0] 3600
[1] 3700
[2] 3701
[3] 3703
[4] 3705
[5] 3706
[6] 3707
[7] 3708
[8] 3709
[9] 3710
[10] 3711
[11] 3712
[12] 3713
[13] 3714
[14] 3715
[15] 3716
[16] 3717
[17] 3718
[18] 5600
[19] 6000
[20] 6100
[21] 6300
[22] 6600
[23] 6800
[24] 6900
[25] 6901
[26] 6902
[27] 6906
[28] 7000
[29] 7200
[30] 7300
[31] 7400
[32] 7500
[33] 7600
[34] 7700
[35] 7800
[36] 8000
[37] 8200
[38] 8300
[39] 8400
[…] …
Machine data and parameters
1636
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p6996[0...63]
Recorder signals / Rec sig
A_INF (Rec), R_INF
Can be changed: T, U
Calculated: -
Access level: 4
(Rec)
Data type: Unsigned32
Dynamic index: -
Function diagram: 8144
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
996553699
[0] 3600
[1] 3700
[2] 3701
[3] 3703
[4] 3705
[5] 3706
[6] 3707
[7] 3708
[8] 3709
[9] 3710
[10] 3713
[11] 3714
[12] 3715
[13] 3716
[14] 3717
[15] 3718
[16] 6600
[17] 6900
[18] 6901
[19] 6902
[20] 6906
[21] 6800
[22] 7000
[23] 7400
[24] 7500
[25] 7600
[26] 7700
[27] 7800
[28] 8200
[29] 8800
[30] 9400
[31] 89800
[32] 89900
[33] 7201
[34] 340200
[35] 355400
[36] 366100
[37] 366200
[38] 183800
[39] 183900
[…] …
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1637
SINAMICS parameters
3.2 SINAMICS parameters
p6996[0...63]
Recorder signals / Rec sig
B_INF (Rec)
Can be changed: T, U
Calculated: -
Access level: 4
Data type: Unsigned32
Dynamic index: -
Function diagram: 8144
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
996553699
[0] 3600
[1] 3700
[2] 3701
[3] 3703
[4] 3711
[5] 3712
[6] 6600
[7] 6800
[8] 7000
[9] 8200
[10] 9400
[11] 89800
[12] 89900
[13] 7200
[14] 183800
[15] 183900
[16] 723000
[17] 723001
[18] 703100
[19...63] 0
Machine data and parameters
1638
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p6996[0...63]
Recorder signals / Rec sig
S_INF (Rec)
Can be changed: T, U
Calculated: -
Access level: 4
Data type: Unsigned32
Dynamic index: -
Function diagram: 8144
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
996553699
[0] 3600
[1] 3700
[2] 3701
[3] 3703
[4] 3705
[5] 3706
[6] 3707
[7] 3708
[8] 3709
[9] 3710
[10] 3711
[11] 3712
[12] 3713
[13] 3714
[14] 3715
[15] 3716
[16] 3717
[17] 3718
[18] 6600
[19] 6900
[20] 6901
[21] 6902
[22] 6906
[23] 6800
[24] 7000
[25] 7600
[26] 7700
[27] 7800
[28] 9400
[29] 89800
[30] 89900
[31] 7200
[32] 183800
[33] 183900
[34] 340500
[35] 345200
[36] 344501
[37] 344602
[38] 344700
[39] 366100
[…] …
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1639
SINAMICS parameters
3.2 SINAMICS parameters
r6997
CO: Recorder sequencer state / Rec state
A_INF (Rec), B_INF
Can be changed: -
Calculated: -
Access level: 4
(Rec), R_INF (Rec),
Data type: Integer16
Dynamic index: -
Function diagram: 8145
S_INF (Rec), SERVO
P-Group: Closed-loop control
Unit group: -
Unit selection: -
(Rec), SERVO_AC (Rec),
VECTOR (Rec),
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC (Rec)
Min:
Max:
Factory setting:
0
60
-
p6998[0...4]
BI: Recorder trigger 1 signal sources / Rec trig 1 s_s
A_INF (Rec), B_INF
Can be changed: T, U
Calculated: -
Access level: 4
(Rec), R_INF (Rec),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 8144
S_INF (Rec), SERVO
P-Group: -
Unit group: -
Unit selection: -
(Rec), SERVO_AC (Rec),
VECTOR (Rec),
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC (Rec)
Min:
Max:
Factory setting:
-
-
[0] 1
[1...4] 0
p6999[0...4]
Recorder parameterization / Rec par
A_INF (Rec), B_INF
Can be changed: T, U
Calculated: -
Access level: 4
(Rec), R_INF (Rec),
Data type: Integer16
Dynamic index: -
Function diagram: 8144, 8145
S_INF (Rec), SERVO
P-Group: -
Unit group: -
Unit selection: -
(Rec), SERVO_AC (Rec),
VECTOR (Rec),
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC (Rec)
Min:
Max:
Factory setting:
0
2000
[0] 1
[1] 1000
[2] 900
[3] 0
[4] 0
r7000
CO: Par_circuit No. of active power units / Qty active PU
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
(Parallel), S_INF
P-Group: Modulation
Unit group: -
Unit selection: -
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
-
-
-
p7001[0...n]
Par_circuit power units enable / PU enable
A_INF (Parallel), B_INF
Can be changed: T
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: Integer16
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Modulation
Unit group: -
Unit selection: -
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
0
1
1
Machine data and parameters
1640
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r7002[0...n]
CO: Par_circuit status power units / Status PU
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: Integer16
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Modulation
Unit group: -
Unit selection: -
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
0
1
-
p7003
Par_circuit winding system / Wind_sys
VECTOR (Parallel),
Can be changed: C2(2)
Calculated: -
Access level: 3
VECTOR_AC (Parallel)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p7010
Par_circuit current asymmetry alarm threshold / i_asym A thr
A_INF (Parallel), R_INF
Can be changed: T, U
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel), VECTOR
P-Group: Modulation
Unit group: -
Unit selection: -
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
2 [%]
100 [%]
20 [%]
p7011
Par_circuit DC link voltage asymmetry alarm threshold / Vdc_dissym A thr
A_INF (Parallel), B_INF
Can be changed: T, U
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel), S_INF
P-Group: Modulation
Unit group: -
Unit selection: -
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: PERCENT
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
2 [%]
100 [%]
10 [%]
p7015
Par_circuit holding brake power unit data set / Brake PDS
VECTOR (Parallel),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (Parallel)
Data type: Integer16
Dynamic index: -
Function diagram: 2701, 2814
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
99
99
r7020[0...n]
CO: Par_circuit deviation current in phase U / Phase U curr dev
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1641
SINAMICS parameters
3.2 SINAMICS parameters
r7021[0...n]
CO: Par_circuit deviation current in phase V / Phase V curr dev
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r7022[0...n]
CO: Par_circuit deviation current in phase W / Phase W curr dev
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r7025
CO: Par_circuit max. deviation currents phase U / Phase U Max i_dev
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r7026
CO: Par_circuit max. deviation currents phase V / Phase V Max i_dev
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r7027
CO: Par_circuit max. deviation currents phase W / Phase W Max i_dev
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r7030[0...n]
CO: Par_circuit DC link voltage deviation / Vdc deviation
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: -
Unit selection: -
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2001
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
Machine data and parameters
1642
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r7031
CO: Par_circuit DC link voltage maximum deviation / Vdc deviation max
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: -
Unit selection: -
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2001
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p7035[0...n]
Par_circuit circulating current control operating mode / I_cct_ctrl mode
VECTOR (Parallel),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (Parallel)
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
1
p7035
Infeed par_circuit circulating current control operating mode / I_cct_ctrl mode
A_INF (Parallel), R_INF
Can be changed: T, U
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: Integer16
Dynamic index: -
Function diagram: -
(Parallel)
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
1
p7036[0...n]
Par_circuit circulating current control proportional gain / Circ_I Kp
VECTOR (Parallel),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
VECTOR_AC (Parallel)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [ohm]
200.00000 [ohm]
0.00000 [ohm]
p7036
Infeed par_cct circulating current controller proportional gain / Circ_I Kp
A_INF (Parallel), R_INF
Can be changed: T, U
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel)
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [%]
1000.00000 [%]
100.00000 [%]
p7037[0...n]
Par_circuit circulating current control integral time / I_cct Tn
VECTOR (Parallel),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
VECTOR_AC (Parallel)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
2.0
1000.0
4.0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1643
SINAMICS parameters
3.2 SINAMICS parameters
p7037
Infeed par_cct circulating current control integral time / I_cct Tn
A_INF (Parallel), R_INF
Can be changed: T, U
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel)
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
100000.0 [%]
100.0 [%]
p7038[0...n]
Par_circuit circulating current control limit / I_cct limit
VECTOR (Parallel),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
VECTOR_AC (Parallel)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [%]
100 [%]
50 [%]
p7038
Infeed par_circuit circulating current control limit / I_cct limit
A_INF (Parallel), R_INF
Can be changed: T, U
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel)
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [%]
100 [%]
100 [%]
p7040[0...n]
Par_circuit correction valve lockout time phase U / Comp t_lockout U
A_INF (Parallel), R_INF
Can be changed: T, U
Calculated: -
Access level: 4
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Modulation
Unit group: -
Unit selection: -
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000000.00 [µs]
1000000.00 [µs]
0.00 [µs]
p7041[0...n]
Par_circuit correction valve lockout time phase U negative / Comp t_lock U neg
VECTOR (Parallel),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (Parallel)
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000000.00 [µs]
1000000.00 [µs]
0.00 [µs]
p7042[0...n]
Par_circuit correction valve lockout time phase V / Comp t_lockout V
A_INF (Parallel), R_INF
Can be changed: T, U
Calculated: -
Access level: 4
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Modulation
Unit group: -
Unit selection: -
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000000.00 [µs]
1000000.00 [µs]
0.00 [µs]
Machine data and parameters
1644
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p7043[0...n]
Par_circuit correction valve lockout time phase V negative / Comp t_lock V neg
VECTOR (Parallel),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (Parallel)
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000000.00 [µs]
1000000.00 [µs]
0.00 [µs]
p7044[0...n]
Par_circuit correction valve lockout time phase W / Comp t_lockout W
A_INF (Parallel), R_INF
Can be changed: T, U
Calculated: -
Access level: 4
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Modulation
Unit group: -
Unit selection: -
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000000.00 [µs]
1000000.00 [µs]
0.00 [µs]
p7045[0...n]
Par_circuit correction valve lockout time phase W negative / Comp t_lock W neg
VECTOR (Parallel),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (Parallel)
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000000.00 [µs]
1000000.00 [µs]
0.00 [µs]
r7050[0...n]
Par_circuit circulating current phase U / Circ_I_phase U
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r7051[0...n]
Par_circuit circulating current phase V / Circ_I_phase V
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r7052[0...n]
Par_circuit circulating current phase W / Circ_I_phase W
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1645
SINAMICS parameters
3.2 SINAMICS parameters
r7100[0...99]
Par_circuit ring buffer fault/alarm code / Fault/alarm code
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: Unsigned32
Dynamic index: -
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: -
Unit selection: -
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
-
-
-
r7101[0...99]
Par_circuit ring buffer data set number / Ring buffer Ds_no
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: Unsigned32
Dynamic index: -
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: -
Unit selection: -
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
-
-
-
r7102[0...99]
Par_circuit ring buffer fault/alarm received / F/A received
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: Unsigned32
Dynamic index: -
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: -
Unit selection: -
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
-
-
-
r7103[0...99]
Par_circuit ring buffer fault/alarm gone / F/A gone
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: Unsigned32
Dynamic index: -
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: -
Unit selection: -
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
-
-
-
r7198[0...n]
Par_connection power unit temperatures cooling unit intake / PU temp RKA intake
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7199[0...n]
Par_circuit power unit temperatures capacitor air discharge / PU temp capacitor
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
Machine data and parameters
1646
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r7200[0...n]
Par_circuit power unit overload I2t / PU overload I2t
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: -
Unit selection: -
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r7201[0...n]
CO: Par_circuit power unit temperatures max. inverter / PU temp max inv
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7202[0...n]
Par_circuit power unit temperatures max. depletion layer / PU TempMaxDepLayer
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7203[0...n]
CO: Par_circuit power unit temperatures max. rectifier / PU temp max rect
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7204[0...n]
CO: Par_circuit power unit temperatures air intake / PU temp air intake
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7205[0...n]
Par_circuit power unit temperatures electronics / PU temp electr
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1647
SINAMICS parameters
3.2 SINAMICS parameters
r7206[0...n]
Par_circuit power unit temperatures inverter 1 / PU temp inv 1
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7207[0...n]
Par_circuit power unit temperatures inverter 2 / PU temp inv 2
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7208[0...n]
Par_circuit power unit temperatures inverter 3 / PU temp inv 3
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7209[0...n]
Par_circuit power unit temperatures inverter 4 / PU temp inv 4
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7210[0...n]
Par_circuit power unit temperatures inverter 5 / PU temp inv 5
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7211[0...n]
Par_circuit power unit temperatures inverter 6 / PU temp inv 6
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
Machine data and parameters
1648
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r7212[0...n]
Par_circuit power unit temperatures inverter 1 / PU temp rect 1
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7213[0...n]
Par_circuit power unit temperatures inverter 2 / PU temp rect 2
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7214[0...n]
Par_circuit power unit temperatures depletion layer 1 / PU temp DepLayer 1
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7215[0...n]
Par_circuit power unit temperatures depletion layer 2 / PU temp DepLayer 2
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7216[0...n]
Par_circuit power unit temperatures depletion layer 3 / PU temp DepLayer 3
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7217[0...n]
Par_circuit power unit temperatures depletion layer 4 / PU temp DepLayer 4
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1649
SINAMICS parameters
3.2 SINAMICS parameters
r7218[0...n]
Par_circuit power unit temperatures depletion layer 5 / PU temp DepLayer 5
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7219[0...n]
Par_circuit power unit temperatures depletion layer 6 / PU temp DepLayer 6
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7220[0...n]
CO: Par_circuit drive output current maximum / Drv I_outp max
VECTOR (Parallel),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (Parallel)
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r7220[0...n]
Infeed par_circuit absolute current value motoring permissible / INF I_abs mot perm
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel)
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r7221[0...n]
Infeed par_circuit absolute current regenerating permissible / INF I_absRegenPerm
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel)
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r7222[0...n]
CO: Par_circuit absolute current actual value / I_act AbsV
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
Machine data and parameters
1650
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r7223[0...n]
CO: Par_circuit phase current actual value phase U / I_phase U ActV
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r7224[0...n]
CO: Par_circuit phase current actual value phase V / I_phase V ActV
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r7225[0...n]
CO: Par_circuit phase current actual value phase W / I_phase W ActV
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r7226[0...n]
CO: Par_circuit phase current actual value phase U offset / I_phase U offset
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r7227[0...n]
CO: Par_circuit phase current actual value phase V offset / I_phase V offset
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r7228[0...n]
CO: Par_circuit phase current actual value phase W offset / I_phase W offset
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1651
SINAMICS parameters
3.2 SINAMICS parameters
r7229[0...n]
CO: Par_circuit phase current actual value sum U, V, W / I_phase sum UVW
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), VECTOR
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
(Parallel), VECTOR_AC
(Parallel)
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r7230[0...n]
CO: Par_circuit DC link voltage actual value / Vdc_ActV
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
(Parallel), S_INF
P-Group: Displays, signals
Unit group: 5_2
Unit selection: p0505
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: p2001
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r7231[0...n]
CO: Par_circuit phase voltage actual value phase U / U_phase U ActV
S_INF (Parallel),
Can be changed: -
Calculated: -
Access level: 3
VECTOR (Parallel),
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
VECTOR_AC (Parallel)
P-Group: Displays, signals
Unit group: 5_3
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r7231[0...n]
CO: Par_circuit phase voltage actual value phase U / U_phase U ActV
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel)
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Displays, signals
Unit group: 5_3
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r7232[0...n]
CO: Par_circuit phase voltage actual value phase V / U_phase V ActV
S_INF (Parallel),
Can be changed: -
Calculated: -
Access level: 3
VECTOR (Parallel),
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
VECTOR_AC (Parallel)
P-Group: Displays, signals
Unit group: 5_3
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r7232[0...n]
CO: Par_circuit phase voltage actual value phase V / U_phase V ActV
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel)
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Displays, signals
Unit group: 5_3
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
Machine data and parameters
1652
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r7233[0...n]
CO: Par_circuit phase voltage actual value phase W / U_phase W ActV
S_INF (Parallel),
Can be changed: -
Calculated: -
Access level: 3
VECTOR (Parallel),
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
VECTOR_AC (Parallel)
P-Group: Displays, signals
Unit group: 5_3
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r7233[0...n]
CO: Par_circuit phase voltage actual value phase W / U_phase W ActV
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel)
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Displays, signals
Unit group: 5_3
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r7240[0...n]
Par_circuit gating unit status word 1 / Gating unit ZSW1
VECTOR (Parallel),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (Parallel)
Data type: Unsigned16
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7240[0...n]
Par_circuit gating unit status word 1 / Gating unit ZSW1
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 4
(Parallel), S_INF
Data type: Unsigned16
Dynamic index: PDS, p0120
Function diagram: -
(Parallel)
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7250[0...4]
Par_circuit power unit rated power / PU P_rated
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 2
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel), S_INF
P-Group: Converter
Unit group: 14_6
Unit selection: p0100
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r7251[0...4]
Par_circuit power unit rated current / PU PI_rated
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 2
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel), S_INF
P-Group: Converter
Unit group: -
Unit selection: -
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1653
SINAMICS parameters
3.2 SINAMICS parameters
r7252[0...4]
Par_circuit maximum power unit current / PU I_max
A_INF (Parallel), B_INF
Can be changed: -
Calculated: -
Access level: 2
(Parallel), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel), S_INF
P-Group: Converter
Unit group: -
Unit selection: -
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r7300[0...n]
CO: Par_circuit VSM input line voltage u1 - u2 / VSM inp u1-u2
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: p0140
Function diagram: -
(Parallel)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r7301[0...n]
CO: Par_circuit VSM input line voltage u2 - u3 / VSM inp u2-u3
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: p0140
Function diagram: -
(Parallel)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r7305[0...n]
Par_circuit VSM temperature evaluation status / VSM temp status
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: Unsigned16
Dynamic index: p0140
Function diagram: -
(Parallel)
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r7306[0...n]
CO: Par_connect VSM temperature actual value / VSM Temp_ActV
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: p0140
Function diagram: -
(Parallel)
P-Group: Closed-loop control
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r7310[0...n]
CO: Par_circuit VSM 10 V input CT1 actual value / VSM CT 1 I_ActV
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: p0140
Function diagram: -
(Parallel)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
Machine data and parameters
1654
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r7311[0...n]
CO: Par_circuit VSM 10 V input CT2 actual value / VSM CT 2 I_ActV
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: p0140
Function diagram: -
(Parallel)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r7315[0...n]
CO: Par_circuit VSM 10 V input 1 actual value / VSM inp 1 U_ActV
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: p0140
Function diagram: -
(Parallel)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r7316[0...n]
CO: Par_circuit VSM 10 V input 2 actual value / VSM inp 2 U_ActV
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: p0140
Function diagram: -
(Parallel)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r7320[0...n]
Par_circuit VSM line filter capacitance phase U / VSM filt C phase U
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 4
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: p0140
Function diagram: -
(Parallel)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [µF]
- [µF]
- [µF]
r7321[0...n]
Par_circuit VSM line filter capacitance phase V / VSM filt C phase V
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 4
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: p0140
Function diagram: -
(Parallel)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [µF]
- [µF]
- [µF]
r7322[0...n]
Par_circuit VSM line filter capacitance phase W / VSM filt C phase W
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 4
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: p0140
Function diagram: -
(Parallel)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [µF]
- [µF]
- [µF]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1655
SINAMICS parameters
3.2 SINAMICS parameters
p7324
Par_connection VSM voltage asymmetry alarm threshold / VSM volt asym thr
A_INF (Parallel), R_INF
Can be changed: T, U
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel)
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
2 [%]
100 [%]
10 [%]
r7325
CO: Par_connection VSM maximum deviation voltage u1 - u2 / VSM max dev U 12
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel)
P-Group: Displays, signals
Unit group: 5_3
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r7326
CO: Par_connection VSM maximum deviation voltage u2 - u3 / VSM max dev U 23
A_INF (Parallel), R_INF
Can be changed: -
Calculated: -
Access level: 3
(Parallel), S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Parallel)
P-Group: Displays, signals
Unit group: 5_3
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p7601
Creation-Ydb quantity / Creation-Ydb qty
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
65535
1
p7602[0...n]
Creation-Ydb / Creation-Ydb
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: p7601
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p7603
SaTopo-Ydb quantity / SaTopo-Ydb qty
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
65535
1
Machine data and parameters
1656
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p7604[0...n]
SaTopo-Ydb / SaTopo-Ydb
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: p7603
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p7605
Connection-Ydb quantity / Conn-Ydb qty
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
65535
1
p7606[0...n]
Connection-Ydb / Conn-Ydb
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: p7605
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p7607
Timestamp-Txt quantity / Timestamp-Txt qty
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
65535
1
p7608[0...n]
Timestamp-Txt / Timestamp-Txt
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: p7607
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p7620
Header-Ydb SubDO quantity / Head-Ydb SubDO qty
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
65535
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1657
|