SINAMICS parameters
3.2 SINAMICS parameters
p3900
Completion of quick commissioning / Compl quick_com
A_INF, B_INF, R_INF,
Can be changed: C2(1)
Calculated: -
Access level: 1
S_INF
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
p3901[0...n]
Power unit EEPROM Vdc offset calibration / PU EEPROM Vdc offs
A_INF, B_INF, R_INF,
Can be changed: C1, C2(1), T
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: All groups
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-40.0 [V]
40.0 [V]
0.0 [V]
p3902[0...n]
Power unit EEPROM Vdc calibration / PU EEPROM Vdc cal
A_INF, B_INF, R_INF,
Can be changed: C1, C2(1), T
Calculated: -
Access level: 8
S_INF, SERVO,
Data type: Unsigned32
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: All groups
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
0
p3909[0...n]
Fan control configuration / Fan ctrl config
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 8
S_INF, SERVO,
Data type: Unsigned16
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: -
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p3920
Power unit test case selection 2 / PU test case sel 2
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p3921
Power unit test value 3 / PU test value 3
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
65535
0
Machine data and parameters
1452
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r3925[0...n]
Identification final display / ID final_disp
SERVO, SERVO_AC
Can be changed: -
Calculated: CALC_MOD_ALL
Access level: 3
Data type: Unsigned32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3925[0...n]
Identification final display / ID final_disp
VECTOR, VECTOR_AC
Can be changed: -
Calculated: CALC_MOD_ALL
Access level: 3
Data type: Unsigned32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3926[0...n]
Voltage generation alternating base voltage amplitude / U_gen altern base
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r3927[0...n]
Motor data identification induction motor data determined / MotID ASM dat det
SERVO, SERVO_AC
Can be changed: -
Calculated: CALC_MOD_ALL
Access level: 3
Data type: Unsigned32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3927[0...n]
Motor data identification control word / MotID STW
VECTOR, VECTOR_AC
Can be changed: -
Calculated: CALC_MOD_ALL
Access level: 3
Data type: Unsigned32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3928[0...n]
Motor data identification synchronous motor data determined / MotId PMSM dat det
SERVO, SERVO_AC
Can be changed: -
Calculated: CALC_MOD_ALL
Access level: 3
Data type: Unsigned32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1453
SINAMICS parameters
3.2 SINAMICS parameters
r3928[0...n]
Rotating measurement configuration / Rot meas config
VECTOR (n/M),
Can be changed: -
Calculated: CALC_MOD_ALL
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned16
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3929[0...n]
Motor data identification modulated voltage generation / MotID U_gen mod
VECTOR, VECTOR_AC
Can be changed: -
Calculated: CALC_MOD_ALL
Access level: 8
Data type: Unsigned32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3938[0...255]
Production test supplementary functions / Prod_test supp_fct
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
4294967295
0
p3939[0...6]
Manufacturing test / Manufacturing test
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
15
0
p3940[0...n]
Motor/controller data calculation / Mot/ctrl_data calc
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
p3950
Service parameter / Serv par
CU_S_AC_DP,
Can be changed: C1, T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: All groups
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1454
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3951[0...9]
Memory address / Mem addr
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 8
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: -
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
r3952[0...7]
CO: Memory contents / Memory contents
A_INF, B_INF, HLA,
Can be changed: -
Calculated: -
Access level: 8
R_INF, S_INF, SERVO,
Data type: Integer32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: -
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3953[0...7]
CO: Memory contents float / Mem content float
A_INF, B_INF, HLA,
Can be changed: -
Calculated: -
Access level: 8
R_INF, S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: -
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3956[0...3]
Par_circuit power unit number / PU_no
A_INF (Parallel), B_INF
Can be changed: T, U
Calculated: -
Access level: 8
(Parallel), R_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
(Parallel), S_INF
P-Group: All groups
Unit group: -
Unit selection: -
(Parallel), VECTOR
(Parallel), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(Parallel)
Min:
Max:
Factory setting:
0
8
0
p3961
Fan operating hours counter / Fan op hr counter
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 3
CU_S_AC_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [h]
340.28235E36 [h]
0.000 [h]
p3961
Fan operating hours counter / Fan op hr counter
CU_S120_DP,
Can be changed: T
Calculated: -
Access level: 8
CU_S120_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.000 [h]
340.28235E36 [h]
0.000 [h]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1455
SINAMICS parameters
3.2 SINAMICS parameters
r3974
Drive unit status word / Drv_unit ZSW
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3977
BICO counter topology / BICO counter topo
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Commands
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3978
BICO CounterDevice / BICO CounterDevice
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Commands
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3979
BICO counter drive object / BICO counter DO
A_INF, B_INF, ENC,
Can be changed: -
Calculated: -
Access level: 4
HLA, HUB, R_INF,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
S_INF, SERVO,
P-Group: Commands
Unit group: -
Unit selection: -
SERVO_AC, TB30,
TM120, TM15, TM150,
Not for motor type: -
Scaling: -
Expert list: 1
TM15DI_DO, TM17,
Min:
Max:
Factory setting:
TM31, TM41,
-
-
-
TM54F_MA,
TM54F_SL, VECTOR,
VECTOR_AC
p3981
Acknowledge drive object faults / Ackn DO faults
All objects
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned8
Dynamic index: -
Function diagram: 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
1456
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3985
Master control mode selection / PcCtrl mode select
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Integer16
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Setpoints
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
r3986
Number of parameters / Par count
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3987
Parameter screen form status display / Par_scr stat_disp
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S_AC_PN,
P-Group: All groups
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, HUB,
Not for motor type: -
Scaling: -
Expert list: 1
R_INF, S_INF, TB30,
Min:
Max:
Factory setting:
TM120, TM15, TM150,
-
-
0000 0000 0000 0000 bin
TM15DI_DO, TM17,
TM31
p3987[0...n]
Parameter screen form status display / Par_scr stat_disp
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC, TM41,
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: -
VECTOR, VECTOR_AC
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p3987[0...n]
Parameter screen form status display / Par_scr stat_disp
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
r3988[0...1]
Boot state / Boot_state
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
10800
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1457
SINAMICS parameters
3.2 SINAMICS parameters
p3990
Sequentially resets drive parameters / Follow par p0970
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 8
S_INF
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
300
0
r3996[0...1]
Parameter write inhibit status / Par_write inhib st
All objects
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3998
First device commissioning / First dev_com
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
-
r3998[0...n]
First drive commissioning / First drv_com
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: DDS, p0180 Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
-
r3998
First infeed commissioning / First INF_com
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
-
r4020[0...4]
TM41 number of inputs and outputs / TM41 I/O count
TM41
Can be changed: -
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1458
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r4021
Digital inputs terminal actual value / DI actual value
SERVO (Dig IO)
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: 2201
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4021
TM15DI/DO digital inputs, terminal actual value / TM15D DI ActV
TM15DI_DO
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: 9400, 9401,
9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4021
TM31 digital inputs terminal actual value / TM31 DI ActV
TM31
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: 9549, 9550,
9552, 9560, 9562
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4021
TM41 digital inputs terminal actual value / TM41 DI ActV
TM41
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4021
TB30 digital inputs terminal actual value / TB30 DI ActV
TB30
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: 9100
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4022.0...1
CO/BO: Digital inputs status / DI status
SERVO (Dig IO)
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 2201
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1459
SINAMICS parameters
3.2 SINAMICS parameters
r4022.0...3
CO/BO: PM330 digital inputs status / PM330 DI status
VECTOR (PM330),
Can be changed: -
Calculated: -
Access level: 8
VECTOR_AC (PM330)
Data type: Unsigned32
Dynamic index: -
Function diagram: 2275
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r4022.0...23
CO/BO: TM15DI/DO digital inputs status / TM15D DI status
TM15DI_DO
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9399, 9400,
9401, 9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4022.0...11
CO/BO: TM31 digital inputs status / TM31 DI status
TM31
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9549, 9550,
9552, 9560, 9562
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4022.0...11
CO/BO: TM41 digital inputs status / TM41 DI status
TM41
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9659, 9660,
9661, 9662
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4022.0...3
CO/BO: TB30 digital inputs status / TB30 DI status
TB30
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9099, 9100
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1460
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r4023.0...1
BO: Digital inputs status inverted / DI status inv
SERVO (Dig IO)
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 2201
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4023.0...3
CO/BO: PM330 digital inputs status inverted / PM330 DI stat inv
VECTOR (PM330),
Can be changed: -
Calculated: -
Access level: 8
VECTOR_AC (PM330)
Data type: Unsigned32
Dynamic index: -
Function diagram: 2275
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r4023.0...23
CO/BO: TM15DI/DO digital inputs status inverted / TM15D DI stat inv
TM15DI_DO
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9399, 9400,
9401, 9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4023.0...11
CO/BO: TM31 digital inputs status inverted / TM31 DI status inv
TM31
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9549, 9550,
9552, 9560, 9562
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4023.0...11
BO: TM41 digital inputs status inverted / TM41 DI status inv
TM41
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9659, 9660,
9661, 9662
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1461
SINAMICS parameters
3.2 SINAMICS parameters
r4023.0...3
BO: TB30 digital inputs status inverted / TB30 DI status inv
TB30
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9099, 9100
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4024
CO: TM15DI/DO digital inputs 16 ... 23 status / TM15D DI 16-23 st
TM15DI_DO
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: 9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4025
CO: TM15DI/DO digital inputs 16 ... 23 status inverted / TM15D DI 16-23 inv
TM15DI_DO
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: 9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p4028
Set input or output / DI or DO
SERVO (Dig IO)
Can be changed: T
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 2201
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p4028
TM15 set input or output / TM15 DI or DO
TM15
Can be changed: T
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: 9389
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
Machine data and parameters
1462
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4028
TM15DI/DO set input or output / TM15D DI or DO
TM15DI_DO
Can be changed: T
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9399, 9400,
9401, 9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
p4028
TM17 set input or output / TM17 DI or DO
TM17
Can be changed: T
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: 9419
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p4028
TM31 set input or output / TM31 DI or DO
TM31
Can be changed: T
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9549, 9560,
9562
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p4028
TM41 set input or output / TM41 DI or DO
TM41
Can be changed: T
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9659, 9661,
9662
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p4030
BI: TM15DI/DO signal source for terminal DI/DO 0 / TM15D s_s DI/DO 0
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9399, 9400
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1463
SINAMICS parameters
3.2 SINAMICS parameters
p4030
BI: TM31 signal source for terminal DO 0 / TM31 s_s DO 0
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9549, 9556
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4030
BI: TB30 signal source for terminal DO 0 / TB30 s_s DO 0
TB30
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9099, 9102
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4031
BI: TM15DI/DO signal source for terminal DI/DO 1 / TM15D s_s DI/DO 1
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9400
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4031
BI: TM31 signal source for terminal DO 1 / TM31 s_s DO 1
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9549, 9556
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4031
BI: TB30 signal source for terminal DO 1 / TB30 s_s DO 1
TB30
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9102
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4032
BI: TM15DI/DO signal source for terminal DI/DO 2 / TM15D s_s DI/DO 2
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9400
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1464
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4032
BI: TB30 signal source for terminal DO 2 / TB30 s_s DO 2
TB30
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9102
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4033
BI: TM15DI/DO signal source for terminal DI/DO 3 / TM15D s_s DI/DO 3
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9400
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4033
BI: TB30 signal source for terminal DO 3 / TB30 s_s DO 3
TB30
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9099, 9102
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4034
BI: TM15DI/DO signal source for terminal DI/DO 4 / TM15D s_s DI/DO 4
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9400
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4035
BI: TM15DI/DO signal source for terminal DI/DO 5 / TM15D s_s DI/DO 5
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9400
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4036
BI: TM15DI/DO signal source for terminal DI/DO 6 / TM15D s_s DI/DO 6
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9400
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1465
SINAMICS parameters
3.2 SINAMICS parameters
p4037
BI: TM15DI/DO signal source for terminal DI/DO 7 / TM15D s_s DI/DO 7
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9400
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4038
BI: Signal source for terminal DI/DO 0 distributed / s_s DI/DO 0 dis
SERVO (Dig IO)
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2201
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4038
BI: TM15DI/DO signal source for terminal DI/DO 8 / TM15D s_s DI/DO 8
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9401
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4038
BI: TM31 signal source for terminal DI/DO 8 / TM31 s_s DI/DO8
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9549, 9560
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4038
BI: TM41 signal source for terminal DI/DO 0 / TM41 s_s DI/DO 0
TM41
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9661
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4039
BI: Signal source for terminal DI/DO 1 distributed / s_s DI/DO 1 dis
SERVO (Dig IO)
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2201
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1466
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4039
BI: TM15DI/DO signal source for terminal DI/DO 9 / TM15D s_s DI/DO 9
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9401
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4039
BI: TM31 signal source for terminal DI/DO 9 / TM31 s_s DI/DO9
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9560
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4039
BI: TM41 signal source for terminal DI/DO 1 / TM41 s_s DI/DO 1
TM41
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9661
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4040
BI: TM15DI/DO signal source for terminal DI/DO 10 / TM15D s_s DI/DO 10
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9401
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4040
BI: TM31 signal source for terminal DI/DO 10 / TM31 s_s DI/DO 10
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9562
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4040
BI: TM41 signal source for terminal DI/DO 2 / TM41 s_s DI/DO 2
TM41
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9662
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1467
SINAMICS parameters
3.2 SINAMICS parameters
p4041
BI: TM15DI/DO signal source for terminal DI/DO 11 / TM15D s_s DI/DO 11
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9401
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4041
BI: TM31 signal source for terminal DI/DO 11 / TM31 s_s DI/DO 11
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9549, 9562
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4041
BI: TM41 signal source for terminal DI/DO 3 / TM41 s_s DI/DO 3
TM41
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9662
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4042
BI: TM15DI/DO signal source for terminal DI/DO 12 / TM15D s_s DI/DO 12
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9401
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4043
BI: TM15DI/DO signal source for terminal DI/DO 13 / TM15D s_s DI/DO 13
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9401
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4044
BI: TM15DI/DO signal source for terminal DI/DO 14 / TM15D s_s DI/DO 14
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9401
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1468
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4045
BI: TM15DI/DO signal source for terminal DI/DO 15 / TM15D s_s DI/DO 15
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9401
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4046
TM31 digital outputs limit current / TM31 DO limit curr
TM31
Can be changed: T
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: 9560
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
r4047
Digital outputs status / DO status
SERVO (Dig IO)
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 2201
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4047
PM330 digital outputs status / PM330 DO status
VECTOR (PM330),
Can be changed: -
Calculated: -
Access level: 8
VECTOR_AC (PM330) Data type: Unsigned32
Dynamic index: -
Function diagram: 2275
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r4047
TM15DI/DO digital outputs status / TM15D DO status
TM15DI_DO
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9400, 9401,
9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4047
TM31 digital outputs status / TM31 DO status
TM31
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9556, 9560,
9562
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1469
SINAMICS parameters
3.2 SINAMICS parameters
r4047
TM41 digital outputs status / TM41 DO status
TM41
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4047
TB30 digital outputs status / TB30 DO status
TB30
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9102
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p4048
Invert digital outputs / DO inv
SERVO (Dig IO)
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 2201
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p4048
TM15 invert digital inputs/outputs / TM15 DI/DO inv
TM15
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
p4048
TM15DI/DO invert digital outputs / TM15D DO inv
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9400, 9401,
9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
Machine data and parameters
1470
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4048
TM17 invert digital inputs/outputs / TM17 DI/DO inv
TM17
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p4048
TM31 invert digital outputs / TM31 DO inv
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9556, 9560,
9562
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p4048
TM41 invert digital outputs / TM41 DO inv
TM41
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p4048
TB30 invert digital outputs / TB30 DO inv
TB30
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9102
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p4049
TM15 digital inputs/outputs set the mode / TM15 DI/DO mode
TM15
Can be changed: T
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
p4049
TM17 digital inputs/outputs set the mode / TM17 DI/DO mode
TM17
Can be changed: T
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1471
SINAMICS parameters
3.2 SINAMICS parameters
r4052[0...1]
CO: TM31 analog inputs current input voltage/current / TM31 AI U/I_inp
TM31
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4052[0]
CO: TM41 analog inputs actual input voltage / TM41 AI U_inp act
TM41
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9663
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r4052[0...1]
CO: TB30 analog inputs actual input voltage / TB30 AI U_inp act
TB30
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9104
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p4053[0...1]
TM31 analog inputs smoothing time constant / TM31 AI Tc_smth
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
1000.0 [ms]
0.0 [ms]
p4053[0]
TM41 analog inputs smoothing time constant / TM41 AI Tc_smth
TM41
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9663
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
1000.0 [ms]
0.0 [ms]
p4053[0...1]
TB30 analog inputs smoothing time constant / TB30 AI Tc_smth
TB30
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9104
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
1000.0 [ms]
0.0 [ms]
Machine data and parameters
1472
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r4055[0...1]
CO: TM31 analog inputs actual value in percent / TM31 AI value in %
TM31
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9549, 9566,
9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r4055[0]
CO: TM41 analog inputs actual value in percent / TM41 AI value in %
TM41
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9663
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r4055[0...1]
CO: TB30 analog inputs actual value in percent / TB30 AI value in %
TB30
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9099, 9104
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p4056[0...1]
TM31 analog inputs type / TM31 AI type
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
5
4
r4056
TM41 analog input type / TM41 AI type
TM41
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
4
4
-
r4056[0...1]
TB30 analog inputs type / TB30 AI type
TB30
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
4
4
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1473
SINAMICS parameters
3.2 SINAMICS parameters
p4057[0...1]
TM31 analog inputs characteristic value x1 / TM31 AI char x1
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000
20.000
0.000
p4057[0]
TM41 analog input characteristic value x1 / TM41 AI char x1
TM41
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9663
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000 [V]
20.000 [V]
0.000 [V]
p4057[0...1]
TB30 analog inputs characteristic value x1 / TB30 AI char x1
TB30
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9104
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-11.000 [V]
11.000 [V]
0.000 [V]
p4058[0...1]
TM31 analog inputs characteristic value y1 / TM31 AI char y1
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [%]
1000.00 [%]
0.00 [%]
p4058[0]
TM41 analog input characteristic value y1 / TM41 AI char y1
TM41
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9663
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [%]
1000.00 [%]
0.00 [%]
p4058[0...1]
TB30 analog inputs characteristic value y1 / TB30 AI char y1
TB30
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9104
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [%]
1000.00 [%]
0.00 [%]
Machine data and parameters
1474
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4059[0...1]
TM31 analog inputs characteristic value x2 / TM31 AI char x2
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000
20.000
10.000
p4059[0]
TM41 analog input characteristic value x2 / TM41 AI char x2
TM41
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9663
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000 [V]
20.000 [V]
10.000 [V]
p4059[0...1]
TB30 analog inputs characteristic value x2 / TB30 AI char x2
TB30
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9104
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-11.000 [V]
11.000 [V]
10.000 [V]
p4060[0...1]
TM31 analog inputs characteristic value y2 / TM31 AI char y2
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [%]
1000.00 [%]
100.00 [%]
p4060[0]
TM41 analog input characteristic value y2 / TM41 AI char y2
TM41
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9663
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [%]
1000.00 [%]
100.00 [%]
p4060[0...1]
TB30 analog inputs characteristic value y2 / TB30 AI char y2
TB30
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9104
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [%]
1000.00 [%]
100.00 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1475
SINAMICS parameters
3.2 SINAMICS parameters
p4061[0...1]
TM31 analog inputs wire breakage monitoring response threshold / TM31 wire brk thr
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [mA]
20.00 [mA]
2.00 [mA]
p4062[0...1]
TM31 analog inputs wire breakage monitoring delay time / TM31 wirebrk t_del
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
100 [ms]
p4063[0...1]
TM31 analog inputs offset / TM31 AI offset
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000
20.000
0.000
p4063[0]
TM41 analog input offset / TM41 AI offset
TM41
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9663
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000 [V]
20.000 [V]
0.000 [V]
p4063[0...1]
TB30 analog inputs offset / TB30 AI offset
TB30
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9104
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000 [V]
20.000 [V]
0.000 [V]
p4066[0...1]
TM31 analog inputs activate absolute value generation / TM31 AI AbsV act
TM31
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
1476
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4066[0]
TM41 analog input activate absolute value generation / TM41 AI AbsV act
TM41
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 9663
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p4066[0...1]
TB30 analog inputs activate absolute value generation / TB30 AI AbsV act
TB30
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 9104
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p4067[0...1]
BI: TM31 analog inputs invert signal source / TM31 AI inv s_s
TM31
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4067[0]
BI: TM41 analog input invert signal source / TM41 AI inv s_s
TM41
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9663
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4067[0...1]
BI: TB30 analog inputs invert signal source / TB30 AI inv s_s
TB30
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9104
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4068[0...1]
TM31 analog inputs window to suppress noise / TM31 AI window
TM31
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
20.00 [%]
0.00 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1477
SINAMICS parameters
3.2 SINAMICS parameters
p4068[0]
TM41 analog input window to suppress noise / TM41 AI window
TM41
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9663
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
20.00 [%]
0.00 [%]
p4068[0...1]
TB30 analog inputs noise suppression window / TB30 AI window
TB30
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9104
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
20.00 [%]
0.00 [%]
p4069[0...1]
BI: TM31 analog inputs signal source for enable / TM31 AI enable
TM31
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p4069[0]
BI: TM41 analog input signal source for enable / TM41 AI enable
TM41
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9663
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p4069[0...1]
BI: TB30 analog inputs signal source for enable / TB30 AI enable
TB30
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9104
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p4071[0...1]
CI: TM31 analog outputs signal source / TM31 AO s_s
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 9549, 9572
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1478
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4071[0...1]
CI: TB30 analog outputs signal source / TB30 AO s_s
TB30
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 9099, 9106
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r4072[0...1]
TM31 analog outputs output value currently referred / TM31 AO outp_val
TM31
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9572
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r4072[0...1]
TB30 analog outputs output value currently referred / TB30 AO outp_val
TB30
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9106
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p4073[0...1]
TM31 analog outputs smoothing time constant / TM31 AO Tc_smth
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9572
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
1000.0 [ms]
0.0 [ms]
p4073[0...1]
TB30 analog outputs smoothing time constant / TB30 AO Tc_smth
TB30
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9106
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
1000.0 [ms]
0.0 [ms]
r4074[0...1]
TM31 analog outputs current output voltage/current / TM31 AO U/I_outp
TM31
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9572
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1479
SINAMICS parameters
3.2 SINAMICS parameters
r4074[0...1]
TB30 analog outputs actual output voltage / TB30 AO U_outp
TB30
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9106
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p4075[0...1]
TM31 analog outputs activate absolute value generation / TM31 AO AbsV act
TM31
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 9572
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p4075[0...1]
TB30 analog outputs activate absolute value generation / TB30 AO AbsV act
TB30
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 9106
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p4076[0...1]
TM31 analog outputs type / TM31 AO type
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: 9572
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4
4
r4076[0...1]
TB30 analog outputs type / TB30 AO type
TB30
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
4
4
-
p4077[0...1]
TM31 analog outputs characteristic value x1 / TM31 AO char x1
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9572
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [%]
1000.00 [%]
0.00 [%]
Machine data and parameters
1480
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4077[0...1]
TB30 analog outputs characteristic value x1 / TB30 AO char x1
TB30
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9106
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [%]
1000.00 [%]
0.00 [%]
p4078[0...1]
TM31 analog outputs characteristic value y1 / TM31 AO char y1
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9572
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000
20.000
0.000
p4078[0...1]
TB30 analog outputs characteristic value y1 / TB30 AO char y1
TB30
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9106
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-11.000 [V]
11.000 [V]
0.000 [V]
p4079[0...1]
TM31 analog outputs characteristic value x2 / TM31 AO char x2
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9572
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [%]
1000.00 [%]
100.00 [%]
p4079[0...1]
TB30 analog outputs characteristic value x2 / TB30 AO char x2
TB30
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9106
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [%]
1000.00 [%]
100.00 [%]
p4080[0...1]
TM31 analog outputs characteristic value y2 / TM31 AO char y2
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9572
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000
20.000
10.000
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1481
SINAMICS parameters
3.2 SINAMICS parameters
p4080[0...1]
TB30 analog outputs characteristic value y2 / TB30 AO char y2
TB30
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9106
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-11.000 [V]
11.000 [V]
10.000 [V]
p4082[0...1]
BI: TM31 analog outputs invert signal source / TM31 AO inv s_s
TM31
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9572
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4082[0...1]
BI: TB30 analog outputs invert signal source / TB30 AO inv s_s
TB30
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9106
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4083[0...1]
TM31 analog outputs offset / TM31 AO offset
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9572
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000
20.000
0.000
p4083[0...1]
TB30 analog outputs offset / TB30 AO offset
TB30
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9106
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10.000
10.000
0.000
p4086
BI: TM15DI/DO signal source for terminal DI/DO 16 / TM15D s_s DI/DO 16
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1482
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4087
BI: TM15DI/DO signal source for terminal DI/DO 17 / TM15D s_s DI/DO 17
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4088
BI: TM15DI/DO signal source for terminal DI/DO 18 / TM15D s_s DI/DO 18
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4089
BI: TM15DI/DO signal source for terminal DI/DO 19 / TM15D s_s DI/DO 19
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4090
BI: TM15DI/DO signal source for terminal DI/DO 20 / TM15D s_s DI/DO 20
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4091
BI: TM15DI/DO signal source for terminal DI/DO 21 / TM15D s_s DI/DO 21
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4092
BI: TM15DI/DO signal source for terminal DI/DO 22 / TM15D s_s DI/DO 22
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1483
SINAMICS parameters
3.2 SINAMICS parameters
p4093
BI: TM15DI/DO signal source for terminal DI/DO 23 / TM15D s_s DI/DO 23
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9402
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r4094.0...23
BO: TM15 digital inputs status inverted raw data internal / TM15 DI st raw dat
TM15DI_DO
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p4095
S120M digital inputs simulation mode / S120M DI sim_mode
SERVO (Dig IO)
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p4095
PM330 digital inputs simulation mode / PM330 DI sim_mode
VECTOR (PM330),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (PM330)
Data type: Unsigned32
Dynamic index: -
Function diagram: 2275
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0000 bin
p4095
TM15DI/DO digital inputs simulation mode / TM15D DI sim_mode
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: 9400, 9401,
9402
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
Machine data and parameters
1484
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4095
TM31 digital inputs simulation mode / TM31 DI sim_mode
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: 9549, 9550,
9552, 9560, 9562
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p4095
TM41 digital inputs simulation mode / TM41 DI sim_mode
TM41
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p4095
TB30 digital inputs simulation mode / TB30 DI sim_mode
TB30
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: 9099, 9100
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p4096
S120M digital inputs simulation mode setpoint / S120M DI sim set
SERVO (Dig IO)
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p4096
PM330 digital inputs simulation mode setpoint / PM330 DI sim set
VECTOR (PM330),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (PM330) Data type: Unsigned32
Dynamic index: -
Function diagram: 2275
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1485
SINAMICS parameters
3.2 SINAMICS parameters
p4096
TM15DI/DO digital inputs simulation mode, setpoint / TM15D DI sim set
TM15DI_DO
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: 9400, 9401,
9402
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
p4096
TM31 digital inputs simulation mode setpoint / TM31 DI sim set
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: 9549, 9550,
9552, 9560, 9562
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p4096
TM41 digital inputs simulation mode setpoint / TM41 DI sim set
TM41
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p4096
TB30 digital inputs simulation mode setpoint / TB30 DI sim set
TB30
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: 9099, 9100
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p4097[0...1]
TM31 analog inputs simulation mode / TM31 AI sim_mode
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
1486
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4097[0]
TM41 analog input simulation mode / TM41 AI sim_mode
TM41
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: 9663
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p4097[0...1]
TB30 analog inputs simulation mode / TB30 AI sim_mode
TB30
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: 9104
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p4098[0...1]
TM31 analog inputs simulation mode setpoint / TM31 AI sim set
TM31
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566, 9568
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000
20.000
0.000
p4098[0]
TM41 analog input simulation mode setpoint / TM41 AI sim set
TM41
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9663
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000 [V]
20.000 [V]
0.000 [V]
p4098[0...1]
TB30 analog inputs simulation mode setpoint / TB30 AI sim set
TB30
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9104
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-11.000 [V]
11.000 [V]
0.000 [V]
p4099
Inputs/outputs sampling time / I/O t_samp
SERVO (Dig IO)
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
125.00 [µs]
5000.00 [µs]
4000.00 [µs]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1487
SINAMICS parameters
3.2 SINAMICS parameters
p4099
TM15 inputs/outputs sampling time / TM15 I/O t_samp
TM15
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9389
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
31.25 [µs]
500.00 [µs]
125.00 [µs]
p4099
TM15DI/DO inputs/outputs sampling time / TM15D I/O t_samp
TM15DI_DO
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9399, 9400
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
5000.00 [µs]
4000.00 [µs]
p4099
TM17 inputs/outputs sampling time / TM17 I/O t_samp
TM17
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9419
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
31.25 [µs]
500.00 [µs]
125.00 [µs]
p4099[0...2]
TM31 inputs/outputs sampling time / TM31 I/O t_samp
TM31
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9549, 9550
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
5000.00 [µs]
4000.00 [µs]
p4099[0...3]
TM41 inputs/outputs sampling time / TM41 I/O t_samp
TM41
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9659, 9660
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
5000.00 [µs]
[0] 4000.00 [µs]
[1] 4000.00 [µs]
[2] 0.00 [µs]
[3] 125.00 [µs]
Machine data and parameters
1488
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4099[0...2]
TB30 inputs/outputs sampling time / TB30 I/O t_samp
TB30
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9099, 9100
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
5000.00 [µs]
[0] 4000.00 [µs]
[1] 4000.00 [µs]
[2] 4000.00 [µs]
p4100
Spindle supplementary temperature sensor type / Sup_temp sens type
SERVO (Spin_diag),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Spin_diag)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
0
p4100[0...3]
TM120 temperature evaluation, sensor type / TM120 sensor type
TM120
Can be changed: T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: 9605, 9606
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
1
p4100[0...11]
TM150 sensor type / TM150 sensor type
TM150
Can be changed: T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: 9626, 9627
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
5
p4100
TM31 sensor type / TM31 sensor type
TM31
Can be changed: T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: 9576
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1489
SINAMICS parameters
3.2 SINAMICS parameters
r4101[0...3]
TM120 sensor resistance / TM120 R_sensor
TM120
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 9605, 9606
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
r4101[0...11]
TM150 sensor resistance / TM150 R_sensor
TM150
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9626, 9627
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
r4101
TM31 sensor resistance / TM31 R_sensor
TM31
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 9576
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
p4102[0...1]
Spindle supplementary temperature fault threshold/alarm thresh. / Suppl_temp F/A_thr
SERVO (Spin_diag),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Spin_diag)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-300.0 [°C]
9999.0 [°C]
[0] 120.0 [°C]
[1] 155.0 [°C]
p4102[0...7]
TM120 fault threshold/alarm threshold / TM120 F/A_thr
TM120
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: 9605, 9606
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-48 [°C]
251 [°C]
251 [°C]
p4102[0...23]
TM150 fault threshold/alarm threshold / TM150 F/A_thr
TM150
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: 9626, 9627
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-99 [°C]
251 [°C]
251 [°C]
Machine data and parameters
1490
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4102[0...1]
TM31 fault threshold/alarm threshold / TM31 F/A_thr
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: 9576
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-48 [°C]
251 [°C]
[0] 100 [°C]
[1] 120 [°C]
p4103
Spindle supplementary temperature delay time / Suppl_temp t_delay
SERVO (Spin_diag),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Spin_diag)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
600.000 [s]
0.000 [s]
p4103[0...3]
TM120 temperature evaluation delay time / TM120 temp t_delay
TM120
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9605, 9606
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [ms]
600000.000 [ms]
0.000 [ms]
p4103[0...11]
TM150 delay time / TM150 t_delay
TM150
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9626, 9627
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [s]
600.0 [s]
0.0 [s]
p4103
TM31 temperature evaluation delay time / TM31 temp t_delay
TM31
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9576
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [ms]
600000.000 [ms]
0.000 [ms]
r4104.0...2
BO: Spindle supplementary temperature status / Suppl_temp status
SERVO (Spin_diag),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Spin_diag)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1491
SINAMICS parameters
3.2 SINAMICS parameters
r4104.0...7
BO: TM120 temperature evaluation status / TM120 temp status
TM120
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: 9605, 9606
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4104.0...23
BO: TM150 temperature evaluation status / TM150 temp status
TM150
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 9626, 9627
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4104.0...1
BO: TM31 temperature evaluation status / TM31 temp status
TM31
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: 9549, 9576
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4105
CO: Spindle supplementary temperature actual value / Suppl_temp ActV
SERVO (Spin_diag),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Spin_diag)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r4105[0...3]
CO: TM120 temperature actual value / TM120 temp_ActV
TM120
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8016, 9605,
9606
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r4105[0...11]
CO: TM150 temperature actual value / TM150 temp_ActV
TM150
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9626, 9627
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
Machine data and parameters
1492
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r4105
CO: TM31 temperature actual value / TM31 temp_ActV
TM31
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9549, 9576
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r4107
Spindle supplementary temperature sensor use / Sup_temp_sens_use
SERVO (Spin_diag),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Spin_diag)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
-
p4108[0...5]
TM150 terminal block measuring method / TM150 meas method
TM150
Can be changed: T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: 9625, 9626,
9627
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
1
p4109[0...11]
TM150 wire resistance measurement / TM150 R_wire meas
TM150
Can be changed: T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: 9626, 9627
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p4110[0...11]
TM150 wire resistance value / TM150 R_wire value
TM150
Can be changed: T
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9626, 9627
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ohm]
3000.00 [ohm]
0.00 [ohm]
p4111[0...2]
TM150 group channel assignment / TM150 grp channel
TM150
Can be changed: T
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: 9625
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1493
SINAMICS parameters
3.2 SINAMICS parameters
r4112[0...2]
CO: TM150 group temperature actual value maximum value / TM150 grp temp max
TM150
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9625
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r4113[0...2]
CO: TM150 group temperature actual value minimum value / TM150 grp temp min
TM150
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9625
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r4114[0...2]
CO: TM150 group temperature average actual value / TM150 grp tempActV
TM150
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9625
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
p4117[0...2]
TM150 group sensor error effect / TM150 error effect
TM150
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: 9625
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p4118[0...11]
TM150 fault threshold/alarm threshold hysteresis / TM150 thr hyst
TM150
Can be changed: T
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: 9626, 9627
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [K]
50 [K]
5 [K]
p4119[0...11]
TM150 activate/deactivate smoothing / TM150 smth act
TM150
Can be changed: T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: 9626, 9627
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
1494
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r4120[0...11]
TM150 actual smoothing time in ms / TM150 ActV t ms
TM150
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: 9626, 9627
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
p4121
TM150 filter rated line frequency / TM150 filt f_line
TM150
Can be changed: T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: 9626, 9627
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p4122[0...11]
TM150 smoothing time constant / TM150 Tc
TM150
Can be changed: T
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: 9626, 9627
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
100 [ms]
10000 [ms]
100 [ms]
r4154
TM41 diagnostics speed setpoint non-filtered / Diag n_set nfilt
TM41
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r4155
TM41 diagnostics speed setpoint / TM41 diag n_set
TM41
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9674
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r4201
TM15 system time for synchronization / TM15 t_system sync
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1495
SINAMICS parameters
3.2 SINAMICS parameters
r4201
TM17 system time for synchronization / TM17 t_system sync
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4204
TM15 control digital output 0 ... 15 / TM15 ctrl DO 0-15
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4204
TM17 control digital output 0 ... 15 / TM17 ctrl DO 0-15
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4205
TM15 control digital output 16 ... 23 / TM15 ctrl DO 16-23
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4211
TM15 edge mode digital input 0 ... 7 / TM15 EdgMd DI0-7
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4211
TM17 edge mode digital input 0 ... 7 / TM17 EdgMd DI 0-7
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1496
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r4212
TM15 edge mode digital input 8 ... 15 / TM15 EdgMd DI8-15
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4212
TM17 edge mode digital input 8 ... 15 / TM17 EdgMd DI 8-15
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4213
TM15 edge mode digital input 16 ... 23 / TM15 EdgMd DI16-23
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p4220
TM17 enable DI/DO 0 ... 5 / TM17 enable 0-5
TM17
Can be changed: T
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p4221
TM17 smoothing time constant digital input 0 ... 15 / TM17 Tc_sm DI 0-15
TM17
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p4222
TM17 time absolute/relative digital output 0 ... 15 / TM17 abs/rel 0-15
TM17
Can be changed: T
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1497
SINAMICS parameters
3.2 SINAMICS parameters
r4250
TM15 set/reset time digital output 0 / TM15 t_set DO 0
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4250
TM17 set/reset time digital output 0 / TM17 t_set DO 0
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4251
TM15 set/reset time digital output 1 / TM15 t_set DO 1
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4251
TM17 set/reset time digital output 1 / TM17 t_set DO 1
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4252
TM15 set/reset time digital output 2 / TM15 t_set DO 2
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4252
TM17 set/reset time digital output 2 / TM17 t_set DO 2
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1498
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r4253
TM15 set/reset time digital output 3 / TM15 t_set DO 3
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4253
TM17 set/reset time digital output 3 / TM17 t_set DO 3
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4254
TM15 set/reset time digital output 4 / TM15 t_set DO 4
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4254
TM17 set/reset time digital output 4 / TM17 t_set DO 4
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4255
TM15 set/reset time digital output 5 / TM15 t_set DO 5
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4255
TM17 set/reset time digital output 5 / TM17 t_set DO 5
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1499
SINAMICS parameters
3.2 SINAMICS parameters
r4256
TM15 set/reset time digital output 6 / TM15 t_set DO 6
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4256
TM17 set/reset time digital output 6 / TM17 t_set DO 6
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4257
TM15 set/reset time digital output 7 / TM15 t_set DO 7
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4257
TM17 set/reset time digital output 7 / TM17 t_set DO 7
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4258
TM15 set/reset time digital output 8 / TM15 t_set DO 8
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4258
TM17 set/reset time digital output 8 / TM17 t_set DO 8
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1500
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r4259
TM15 set/reset time digital output 9 / TM15 t_set DO 9
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4259
TM17 set/reset time digital output 9 / TM17 t_set DO 9
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4260
TM15 set/reset time digital output 10 / TM15 t_set DO 10
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4260
TM17 set/reset time digital output 10 / TM17 t_set DO 10
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4261
TM15 set/reset time digital output 11 / TM15 t_set DO 11
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4261
TM17 set/reset time digital output 11 / TM17 t_set DO 11
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1501
SINAMICS parameters
3.2 SINAMICS parameters
r4262
TM15 set/reset time digital output 12 / TM15 t_set DO 12
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4262
TM17 set/reset time digital output 12 / TM17 t_set DO 12
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4263
TM15 set/reset time digital output 13 / TM15 t_set DO 13
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4263
TM17 set/reset time digital output 13 / TM17 t_set DO 13
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4264
TM15 set/reset time digital output 14 / TM15 t_set DO 14
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4264
TM17 set/reset time digital output 14 / TM17 t_set DO 14
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1502
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r4265
TM15 set/reset time digital output 15 / TM15 t_set DO 15
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4265
TM17 set/reset time digital output 15 / TM17 t_set DO 15
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4266
TM15 set/reset time digital output 16 / TM15 t_set DO 16
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4267
TM15 set/reset time digital output 17 / TM15 t_set DO 17
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4268
TM15 set/reset time digital output 18 / TM15 t_set DO 18
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4269
TM15 set/reset time digital output 19 / TM15 t_set DO 19
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1503
SINAMICS parameters
3.2 SINAMICS parameters
r4270
TM15 set/reset time digital output 20 / TM15 t_set DO 20
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4271
TM15 set/reset time digital output 21 / TM15 t_set DO 21
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4272
TM15 set/reset time digital output 22 / TM15 t_set DO 22
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4273
TM15 set/reset time digital output 23 / TM15 t_set DO 23
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4301
TM15 module synchronization / TM15 module sync
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4301
TM17 module synchronization / TM17 module sync
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1504
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r4304
TM15 status digital input 0 ... 15 / TM15 st DI 0-15
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4304
TM17 status digital input 0 ... 15 / TM17 st DI 0-15
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4305
TM15 status digital input 16 ... 23 / TM15 st DI 16-23
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4311
TM15 edge status digital input 0 ... 7 / TM15 edg st DI 0-7
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4311
TM17 edge status digital input 0 ... 7 / TM17 edg st DI 0-7
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4312
TM15 edge status digital input 8 ... 15 / TM15 edgSt DI 8-15
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1505
SINAMICS parameters
3.2 SINAMICS parameters
r4312
TM17 edge status digital input 8 ... 15 / TM17 edgSt DI 8-15
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4313
TM15 edge status digital input 16 ... 23 / TM15 edgSt DI16-23
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4350
TM15 edge times digital input 0 / TM15 edge_t DI 0
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4350
TM17 edge times digital input 0 / TM17 edge_t DI 0
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4351
TM15 edge times digital input 1 / TM15 edge_t DI 1
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4351
TM17 edge times digital input 1 / TM17 edge_t DI 1
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1506
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r4352
TM15 edge times digital input 2 / TM15 edge_t DI 2
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4352
TM17 edge times digital input 2 / TM17 edge_t DI 2
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4353
TM15 edge times digital input 3 / TM15 edge_t DI 3
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4353
TM17 edge times digital input 3 / TM17 edge_t DI 3
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4354
TM15 edge times digital input 4 / TM15 edge_t DI 4
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4354
TM17 edge times digital input 4 / TM17 edge_t DI 4
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1507
SINAMICS parameters
3.2 SINAMICS parameters
r4355
TM15 edge times digital input 5 / TM15 edge_t DI 5
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4355
TM17 edge times digital input 5 / TM17 edge_t DI 5
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4356
TM15 edge times digital input 6 / TM15 edge_t DI 6
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4356
TM17 edge times digital input 6 / TM17 edge_t DI 6
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4357
TM15 edge times digital input 7 / TM15 edge_t DI 7
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4357
TM17 edge times digital input 7 / TM17 edge_t DI 7
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1508
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r4358
TM15 edge times digital input 8 / TM15 edge_t DI 8
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4358
TM17 edge times digital input 8 / TM17 edge_t DI 8
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4359
TM15 edge times digital input 9 / TM15 edge_t DI 9
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4359
TM17 edge times digital input 9 / TM17 edge_t DI 9
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4360
TM15 edge times digital input 10 / TM15 edge_t DI 10
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4360
TM17 edge times digital input 10 / TM17 edge_t DI 10
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1509
SINAMICS parameters
3.2 SINAMICS parameters
r4361
TM15 edge times digital input 11 / TM15 edge_t DI 11
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4361
TM17 edge times digital input 11 / TM17 edge_t DI 11
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4362
TM15 edge times digital input 12 / TM15 edge_t DI 12
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4362
TM17 edge times digital input 12 / TM17 edge_t DI 12
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4363
TM15 edge times digital input 13 / TM15 edge_t DI 13
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4363
TM17 edge times digital input 13 / TM17 edge_t DI 13
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1510
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r4364
TM15 edge times digital input 14 / TM15 edge_t DI 14
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4364
TM17 edge times digital input 14 / TM17 edge_t DI 14
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4365
TM15 edge times digital input 15 / TM15 edge_t DI 15
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4365
TM17 edge times digital input 15 / TM17 edge_t DI 15
TM17
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4366
TM15 edge times digital input 16 / TM15 edge_t DI 16
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4367
TM15 edge times digital input 17 / TM15 edge_t DI 17
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1511
SINAMICS parameters
3.2 SINAMICS parameters
r4368
TM15 edge times digital input 18 / TM15 edge_t DI 18
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4369
TM15 edge times digital input 19 / TM15 edge_t DI 19
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4370
TM15 edge times digital input 20 / TM15 edge_t DI 20
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4371
TM15 edge times digital input 21 / TM15 edge_t DI 21
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4372
TM15 edge times digital input 22 / TM15 edge_t DI 22
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4373
TM15 edge times digital input 23 / TM15 edge_t DI 23
TM15
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1512
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4400
TM41 encoder emulation operating mode / Enc_emulat mode
TM41
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 9674, 9676
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p4401
TM41 encoder emulation mode / Enc_emulat mode
TM41
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 9674, 9676
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1111 0011 bin
r4402.0...2
CO/BO: TM41 encoder emulation status / Enc_emulat status
TM41
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 9674, 9676
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4403
TM41 encoder emulation operating mode active / Enc_emul mode act
TM41
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 9674, 9676
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p4404
TM41 encoder emulation controller options / Enc_emul ctrl_opt
TM41
Can be changed: C2(4)
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0001 bin
p4408
TM41 encoder emulation pulse number leading encoder / TM41 enc puls no.
TM41
Can be changed: C2(4)
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 9674, 9676
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
16384
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1513
SINAMICS parameters
3.2 SINAMICS parameters
p4418
TM41 encoder emulation fine resolution leading encoder / TM41 fine res
TM41
Can be changed: C2(4)
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: -
Function diagram: 9676
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
2
18
11
r4419
TM41 encoder emulation diagnostics position setpoint / TM41 diag s_set
TM41
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: -
Function diagram: 9676
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p4420
CI: TM41 encoder emulation position setpoint / Enc_emul s_set
TM41
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 9676
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p4421
TM41 encoder emulation deadtime compensation / Enc_emul t_dead
TM41
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9676
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10.00
10.00
0.00
p4422
TM41 encoder emulation position setpoint inversion / Enc_emul s_set inv
TM41
Can be changed: C2(4)
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 9676
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p4423
TM41 encoder emulation standstill adaptation / Enc standst_adpt
TM41
Can be changed: C2(4)
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 9676
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2000
4
Machine data and parameters
1514
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4426
TM41 encoder emulation pulses for zero mark / Enc_emul pulses ZM
TM41
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 9674, 9676
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
16384
0
r4427
TM41 encoder emulation zero mark position / TM41 NM_position
TM41
Can be changed: -
Calculated: -
Access level: 4
Data type: Integer32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p4600[0...n]
Motor temperature sensor 1 sensor type / Temp_sens 1 type
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
60
0
p4601[0...n]
Motor temperature sensor 2 sensor type / Temp_sens 2 type
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
60
0
p4602[0...n]
Motor temperature sensor 3 sensor type / Temp_sens 3 type
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
60
0
p4603[0...n]
Motor temperature sensor 4 sensor type / Temp_sens 4 type
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
60
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1515
SINAMICS parameters
3.2 SINAMICS parameters
p4610[0...n]
Motor temperature sensor 1 sensor type MDS / Temp sens1 typ MDS
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: MDS, p0130 Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
32
10
p4611[0...n]
Motor temperature sensor 2 sensor type MDS / Temp sens2 typ MDS
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: MDS, p0130 Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
32
10
p4612[0...n]
Motor temperature sensor 3 sensor type MDS / Temp sens3 typ MDS
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: MDS, p0130 Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
32
10
p4613[0...n]
Motor temperature sensor 4 sensor type MDS / Temp sens4 typ MDS
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: MDS, p0130 Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
32
10
p4618
Motor Module temperature sensor type / MM temp_sens type
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
0
r4619
CO: Motor Module temperature sensor actual value / MM temp_sens actV
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
Machine data and parameters
1516
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r4620[0...3]
Motor temperature measured / Mot_temp meas
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8016
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
p4622[0...n]
Temperature sensor error lower threshold / Temp_sens low thr
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8016
P-Group: -
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-140 [°C]
20 [°C]
-140 [°C]
p4630[0...n]
Absolute encoder linear measuring step factor / Abs_enc meas fact
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
4294967295
1
p4631[0...n]
Cylinder distance per encoder revolution / x_cyl per rev
HLA
Can be changed: C2(1, 4)
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [µm]
4294967295 [µm]
0 [µm]
p4635[0...n]
Encoder scaling factor acceleration / Scale factor accel
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: 39_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-340.28235E36 [rev/s²]
340.28235E36 [rev/s²]
0.000 [rev/s²]
r4636[0...2]
CO: Encoder acceleration value 1 / Acceleration 1
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: 39_1
Unit selection: p0505
Not for motor type: -
Scaling: p2007
Expert list: 1
Min:
Max:
Factory setting:
- [rev/s²]
- [rev/s²]
- [rev/s²]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1517
SINAMICS parameters
3.2 SINAMICS parameters
r4637[0...2]
CO: Encoder acceleration value 2 / Acceleration 2
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: 39_1
Unit selection: p0505
Not for motor type: -
Scaling: p2007
Expert list: 1
Min:
Max:
Factory setting:
- [rev/s²]
- [rev/s²]
- [rev/s²]
r4638[0...2]
CO: Encoder acceleration value 3 / Acceleration 3
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: 39_1
Unit selection: p0505
Not for motor type: -
Scaling: p2007
Expert list: 1
Min:
Max:
Factory setting:
- [rev/s²]
- [rev/s²]
- [rev/s²]
r4639[0...2]
CO: Encoder supplementary value / Suppl value
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r4640[0...95]
Encoder diagnostics state machine / Enc diag stat_ma
ENC, HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p4641[0...2]
OEM encoder diagnostic signal selection / OEM enc diag sel
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p4642
Encoder fault test function / Encoder fault test
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
0
Machine data and parameters
1518
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p4643[0...n]
DRIVE-CLiQ encoder repeat telegram / DQ enc repeat
SERVO, SERVO_AC
Can be changed: C1(3), C2(4)
Calculated: -
Access level: 4
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0001 0000 0001 bin
p4644
Simulated motor encoder configuration / Sim mot_enc config
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 4
VECTOR (n/M),
Data type: Unsigned16
Dynamic index: -
Function diagram: -
VECTOR_AC (n/M)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0010 bin
r4648.0
CO/BO: Encoder status word / Enc status word
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p4649[0...n]
Encoder function reserve amplitude limit incremental signals / Enc fct amp inc
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
500
0
p4650
Encoder functional reserve component number / Enc fct_res no
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
399
0
r4651[0...3]
Encoder functional reserve / Enc fct_reserve
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4