SINAMICS parameters
3.2 SINAMICS parameters
r2673
CO: EPOS actual acceleration override / a_over act
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3610, 3612,
VECTOR (EPOS),
3616, 3620
VECTOR_AC (EPOS)
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r2674
CO: EPOS actual deceleration override / -a_over act
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3610, 3612,
VECTOR (EPOS),
3616, 3620
VECTOR_AC (EPOS)
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r2675
CO: EPOS actual task / Task act
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer16
Dynamic index: -
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
9
-
r2676
CO: EPOS actual task parameter / Task par act
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2677
CO: EPOS actual task mode / Task mode act
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned16
Dynamic index: -
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1314
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2678
CO: EPOS external block change actual position / Ext blk chg s_act
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3615, 3616,
VECTOR (EPOS),
3620
VECTOR_AC (EPOS)
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
r2680
CO: EPOS clearance reference cam and zero mark / Clear ref_cams/NM
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
r2681
CO: EPOS velocity override effective / v_over effective
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r2682
CO: EPOS residual distance to go / Residual distance
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3635
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
r2683.0...14
CO/BO: EPOS status word 1 / POS_ZSW1
SERVO (Lin, Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Lin, Pos
Data type: Unsigned16
Dynamic index: -
Function diagram: 3645
ctrl)
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2683.0...14
CO/BO: EPOS status word 1 / POS_ZSW1
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned16
Dynamic index: -
Function diagram: 3645
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1315
SINAMICS parameters
3.2 SINAMICS parameters
r2684.0...15
CO/BO: EPOS status word 2 / POS_ZSW2
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned16
Dynamic index: -
Function diagram: 3646
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2685
CO: EPOS corrective value / Correction value
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3635
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
r2686[0...1]
CO: EPOS force limit effective / F_limit eff
SERVO (EPOS, Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (EPOS, Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3616, 3617
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r2686[0...1]
CO: EPOS torque limiting effective / M_limit eff
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3616, 3617
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r2687
CO: EPOS force setpoint / F_set
SERVO (EPOS, Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (EPOS, Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3616, 3617
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [N]
- [N]
- [N]
r2687
CO: EPOS torque setpoint / M_set
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3616, 3617
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Nm]
- [Nm]
- [Nm]
Machine data and parameters
1316
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2688
EPOS position feedback signal tolerance window / Pos_FS tol
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [LU]
2147482647 [LU]
40 [LU]
r2689[0...1]
CO: EPOS position feedback signal display / Pos_FS display
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2690
CO: EPOS position fixed setpoint / Pos fixed val
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3618
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-2147482648 [LU]
2147482647 [LU]
0 [LU]
p2691
CO: EPOS velocity fixed setpoint / v fixed value
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3618
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [1000 LU/min]
40000000 [1000 LU/min]
600 [1000 LU/min]
p2692
CO: EPOS acceleration override, fixed setpoint / a_over fixed val
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3618
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.100 [%]
100.000 [%]
100.000 [%]
p2693
CO: EPOS deceleration override, fixed setpoint / -a_over fixed val
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3618
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.100 [%]
100.000 [%]
100.000 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1317
SINAMICS parameters
3.2 SINAMICS parameters
p2694
CI: LR supplementary setpoint position / Suppl set pos
SERVO (EPOS, Pos ctrl,
Can be changed: T
Calculated: -
Access level: 1
Pos ctrl), SERVO_AC
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
(EPOS, Pos ctrl, Pos
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
ctrl), VECTOR (EPOS,
Pos ctrl, Pos ctrl),
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC (EPOS, Pos
Min:
Max:
Factory setting:
ctrl, Pos ctrl)
-
-
0
p2695
CI: LR supplementary setpoint velocity / Suppl set v
SERVO (EPOS, Pos ctrl,
Can be changed: T
Calculated: -
Access level: 1
Pos ctrl), SERVO_AC
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
(EPOS, Pos ctrl, Pos
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
ctrl), VECTOR (EPOS,
Pos ctrl, Pos ctrl),
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC (EPOS, Pos
Min:
Max:
Factory setting:
ctrl, Pos ctrl)
-
-
0
r2696
CO: EPOS position setpoint fine resolution / s_set fine res
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
r2697
CO: EPOS velocity setpoint fine resolution / v_set fine res
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [1000 LU/min]
- [1000 LU/min]
- [1000 LU/min]
r2700
CO: Reference speed/reference frequency / n_ref/f_ref
ENC, HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC, TM41,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR, VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2700
CO: Reference velocity/reference frequency actual / v_ref/f_ref act
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1318
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2700
CO: Reference frequency / f_ref
A_INF, B_INF, R_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2700
CO: Reference frequency actual / f_ref act
S_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2700
CO: Reference velocity/reference frequency actual / v_ref/f_ref act
ENC (Lin_enc)
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2701
CO: Reference voltage / Reference voltage
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2701
CO: Reference voltage / Reference voltage
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, TM41,
P-Group: -
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2702
CO: Reference current / Reference current
A_INF, B_INF, HLA,
Can be changed: -
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, TM41,
P-Group: -
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1319
SINAMICS parameters
3.2 SINAMICS parameters
r2703
CO: Reference torque / Reference torque
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
TM41, VECTOR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2703
CO: Reference force actual / Ref force cur
HLA, SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2704
CO: Reference power / Reference power
A_INF, B_INF, HLA,
Can be changed: -
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, TM41,
P-Group: -
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2705
CO: Reference angle / Reference angle
A_INF, B_INF, HLA,
Can be changed: -
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, TM41,
P-Group: -
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2706
CO: Reference temperature / Reference temp
A_INF, B_INF, HLA,
Can be changed: -
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, TM120,
P-Group: -
Unit group: -
Unit selection: -
TM150, TM31, TM41,
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2707
CO: Reference acceleration / Ref a
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR, VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1320
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2720[0...n]
Load gear configuration / Load gear config
HLA, SERVO,
Can be changed: C2(1, 4)
Calculated: -
Access level: 1
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: DDS, p0180 Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p2721[0...n]
Load gear rotary absolute encoder revolutions virtual / Abs rot rev
HLA, SERVO,
Can be changed: C2(1, 4)
Calculated: -
Access level: 1
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: DDS, p0180
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4194303
0
p2722[0...n]
Load gear position tracking tolerance window / Pos track tol
HLA, SERVO,
Can be changed: C2(1, 4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
4294967300.00
0.00
r2723[0...n]
CO: Load gear absolute value / Load gear AbsV
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: DDS, p0180
Function diagram: 4010, 4704
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2724[0...n]
CO: Load gear position difference / Load gear pos diff
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC, VECTOR,
Data type: Integer32
Dynamic index: DDS, p0180
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2730[0...3]
BI: LR pos. actual value preprocessing activate neg. corr. (edge) / ActV_prep neg corr
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 4010, 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1321
SINAMICS parameters
3.2 SINAMICS parameters
p2733[0...n]
CO: LR encoder adjustment DDS / Enc_adj DDS
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 4
SERVO_AC (Pos ctrl),
Data type: Unsigned8
Dynamic index: EDS, p0140
Function diagram: 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
0
p2740
Position controller preassignment torque precontrol / Preassgn M_prectrl
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Pos ctrl),
Data type: Integer16
Dynamic index: -
Function diagram: -
VECTOR (Pos ctrl),
P-Group: -
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
r2741
CO: LR acceleration precontrol value / a_prectrl value
SERVO (Lin, Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Lin, Pos
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
ctrl)
P-Group: Closed-loop position control
Unit group: 22_2
Unit selection: p0505
Not for motor type: -
Scaling: p2007
Expert list: 1
Min:
Max:
Factory setting:
- [m/s²]
- [m/s²]
- [m/s²]
r2741
CO: LR acceleration precontrol value / a_prectrl value
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: 39_1
Unit selection: p0505
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: p2007
Expert list: 1
Min:
Max:
Factory setting:
- [rev/s²]
- [rev/s²]
- [rev/s²]
p2780[0...5]
Activate adaptation block / Act adpt block
SERVO (Ctrl_par
Can be changed: T
Calculated: -
Access level: 3
adapt), SERVO_AC
Data type: Unsigned32
Dynamic index: -
Function diagram: 5055
(Ctrl_par adapt)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
p2782[0...5]
Adaptation mode / Adpt mode
SERVO (Ctrl_par
Can be changed: T
Calculated: -
Access level: 3
adapt), SERVO_AC
Data type: Integer16
Dynamic index: -
Function diagram: 5055
(Ctrl_par adapt)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
8
0
Machine data and parameters
1322
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2783[0...5]
Adaptation lower limit value / Adpt lower lim val
SERVO (Ctrl_par
Can be changed: T, U
Calculated: -
Access level: 3
adapt), SERVO_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: 5055
(Ctrl_par adapt)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
500
p2784[0...5]
Adaptation upper limit value / Adpt upper lim val
SERVO (Ctrl_par
Can be changed: T, U
Calculated: -
Access level: 3
adapt), SERVO_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: 5055
(Ctrl_par adapt)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
2000
p2788[0...5]
CI: Adaptation factor signal source / Adpt fact s_s
SERVO (Ctrl_par
Can be changed: T
Calculated: -
Access level: 3
adapt), SERVO_AC
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 5055
(Ctrl_par adapt)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r2789[0...5]
Active adaptation factor / Act adpt fact
SERVO (Ctrl_par
Can be changed: -
Calculated: -
Access level: 3
adapt), SERVO_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5055
(Ctrl_par adapt)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r2790[0...5]
Adaptation denominator natural frequency active / Adapt fn_den act
SERVO (Ctrl_par
Can be changed: -
Calculated: -
Access level: 3
adapt), SERVO_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5055
(Ctrl_par adapt)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
r2791[0...5]
Adaptation numerator natural frequency active / Adapt fn_num act
SERVO (Ctrl_par
Can be changed: -
Calculated: -
Access level: 3
adapt), SERVO_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5055
(Ctrl_par adapt)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1323
SINAMICS parameters
3.2 SINAMICS parameters
p2810[0...1]
BI: AND logic operation inputs / AND inputs
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2634
VECTOR_AC
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r2811.0
CO/BO: AND logic operation result / AND result
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: 2634
VECTOR_AC
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2816[0...1]
BI: OR logic operation inputs / OR inputs
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2634
VECTOR_AC
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r2817.0
CO/BO: OR logic operation result / OR result
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: 2634
VECTOR_AC
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2822[0...3]
BI: NOT logic operation input / NOT input
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2634
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r2823.0...3
CO/BO: NOT logic operation result / NOT result
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned32
Dynamic index: -
Function diagram: 2634
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1324
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2900[0...n]
CO: Fixed value 1 [%] / Fixed value 1 [%]
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 1021
VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-10000.00 [%]
10000.00 [%]
0.00 [%]
p2900
CO: Fixed value 1 [%] / Fixed value 1 [%]
A_INF (Dyn. grid
Can be changed: T, U
Calculated: -
Access level: 3
support, Dyn. grid
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 1021
support, Line transf,
P-Group: Setpoints
Unit group: -
Unit selection: -
Line transf, Line transf,
Line transf, Suppl cl-
Not for motor type: -
Scaling: PERCENT
Expert list: 1
loop ctrl, Suppl cl-loop
Min:
Max:
Factory setting:
ctrl, Suppl cl-loop ctrl),
-10000.00 [%]
10000.00 [%]
0.00 [%]
R_INF (Dyn. grid
support, Dyn. grid
support, Line transf,
Line transf, Line transf,
Line transf, Suppl cl-
loop ctrl, Suppl cl-loop
ctrl, Suppl cl-loop ctrl)
p2901[0...n]
CO: Fixed value 2 [%] / Fixed value 2 [%]
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 1021
VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-10000.00 [%]
10000.00 [%]
0.00 [%]
p2901
CO: Fixed value 2 [%] / Fixed value 2 [%]
A_INF (Dyn. grid
Can be changed: T, U
Calculated: -
Access level: 3
support, Dyn. grid
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 1021
support, Line transf,
P-Group: Setpoints
Unit group: -
Unit selection: -
Line transf, Line transf,
Line transf, Suppl cl-
Not for motor type: -
Scaling: PERCENT
Expert list: 1
loop ctrl, Suppl cl-loop
Min:
Max:
Factory setting:
ctrl, Suppl cl-loop ctrl),
-10000.00 [%]
10000.00 [%]
0.00 [%]
R_INF (Dyn. grid
support, Dyn. grid
support, Line transf,
Line transf, Line transf,
Line transf, Suppl cl-
loop ctrl, Suppl cl-loop
ctrl, Suppl cl-loop ctrl)
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1325
SINAMICS parameters
3.2 SINAMICS parameters
r2902[0...14]
CO: Fixed values [%] / Fixed values [%]
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 1021
VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p2909
Characteristic measurement control word / Char meas STW
VECTOR, VECTOR_AC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p2911
Activating characteristic measurement / Char meas act
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4
0
p2913[0...9]
Characteristic measurement comparison value / Char comp_value
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-500.00 [%]
500.00 [%]
100.00 [%]
r2914.0...18
BO: Characteristic measurement status / Char meas status
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2920[0...1]
Characteristic measurement lower limit / Lower char limit
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-500.00 [%]
500.00 [%]
-100.00 [%]
Machine data and parameters
1326
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2921[0...1]
Characteristic measurement upper limit / Upper char limit
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-500.00 [%]
500.00 [%]
100.00 [%]
p2922[0...1]
Characteristic measurement number of measurement points / Char meas pts qty
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
21
p2923[0...1]
Characteristic measurement ramp time / Char t_ramp
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000000 [ms]
100 [ms]
p2924[0...1]
Characteristic measurement wait time / Char t_wait
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000000 [ms]
10 [ms]
p2925[0...1]
Characteristic measurement cool-down time / Char t_cool
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000000 [ms]
10 [ms]
p2926[0...1]
CO: Characteristic measurement setpoint / Char meas set
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-10000.00 [%]
10000.00 [%]
0.00 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1327
SINAMICS parameters
3.2 SINAMICS parameters
p2927[0...1]
Characteristic measurement speed / Char n
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [%]
150 [%]
[0] 60 [%]
[1] 5 [%]
r2928
Characteristic measurement progress display / Char progress
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p2930[0...n]
CO: Fixed value F [N] / Fixed value F [N]
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Setpoints
Unit group: 8_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-100000.00 [N]
100000.00 [N]
0.00 [N]
p2930[0...n]
CO: Fixed value M [Nm] / Fixed value M [Nm]
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 1021
P-Group: Setpoints
Unit group: 7_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-100000.00 [Nm]
100000.00 [Nm]
0.00 [Nm]
p2930[0...n]
CO: Fixed value F [N] / Fixed value F [N]
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 1021
P-Group: Setpoints
Unit group: 8_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-100000.00 [N]
100000.00 [N]
0.00 [N]
p2952[0...n]
Flux characteristic coefficient K01 / Psid_mod K01
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1328
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2953[0...n]
Flux characteristic coefficient K02 / Psid_mod K02
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2954[0...n]
Flux characteristic coefficient K03 / Psid_mod K03
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2955[0...n]
Flux characteristic coefficient K04 / Psid_mod K04
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2969[0...6]
Flux model value display / Psi_mod val disp
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2970[0...n]
Optimum flux characteristic torque scaling value / Opt_char M scal
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0000 [Nm]
10000.0000 [Nm]
0.0000 [Nm]
p2970[0...n]
Optimum flux characteristic torque scaling value / Opt_char M scal
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0000 [N]
10000.0000 [N]
0.0000 [N]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1329
SINAMICS parameters
3.2 SINAMICS parameters
p2971[0...n]
Optimum flux characteristic coefficient K1 / Opt_char K1
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2971[0...n]
Optimum flux characteristic coefficient K1 / Opt_char K1
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2972[0...n]
Optimum flux characteristic coefficient K2 / Opt_char K2
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2972[0...n]
Optimum flux characteristic coefficient K2 / Opt_char K2
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2973[0...n]
Optimum flux characteristic coefficient K3 / Opt_char K3
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2973[0...n]
Optimum flux characteristic coefficient K3 / Opt_char K3
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1330
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2974[0...n]
Optimum flux characteristic rotor losses weighting / Opt_char rot wt
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2974[0...n]
Optimum flux characteristic coefficient K4 / Opt_char K4
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, SESM, REL
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
p2975[0...n]
Optimum flux characteristic coefficient K5 / Opt_char K5
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, SESM, REL
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
p2980[0...n]
Quadrature axis flux model coefficient K01 / Psiq_mod K01
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2981[0...n]
Quadrature axis flux model coefficient K02 / Psiq_mod K02
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2982[0...n]
Quadrature axis flux model coefficient K03 / Psiq_mod K03
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1331
SINAMICS parameters
3.2 SINAMICS parameters
p2983[0...n]
Quadrature axis flux model coefficient K04 / Psiq_mod K04
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3011[0...n]
MotID current control adaptation lower starting point identified / I_adapt low ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
6000.00 [Arms]
0.00 [Arms]
p3012[0...n]
MotID current control adaptation upper starting point identified / I_adapt up ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
6000.00 [Arms]
0.00 [Arms]
p3013[0...n]
MotId current controller adaptation P gain identified / I_adapt Kp ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
1000.00 [%]
0.00 [%]
p3016
MotId torque constant identified / kT ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: 28_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm/A]
100.00 [Nm/A]
0.00 [Nm/A]
p3016
MotId force constant identified / kT ident
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: 29_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [N/Arms]
1000.00 [N/Arms]
0.00 [N/Arms]
Machine data and parameters
1332
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3017
MotId voltage constant identified / kE ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Vrms]
10000.0 [Vrms]
0.0 [Vrms]
p3017
MotId voltage constant identified / kE ident
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Vrms s/m]
1000.0 [Vrms s/m]
0.0 [Vrms s/m]
p3020
MotId magnetizing current identified / I_mag ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [Arms]
5000.000 [Arms]
0.000 [Arms]
p3027
MotId optimum load angle identified / phi_load opt ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [°]
135.0 [°]
0.0 [°]
p3028
MotId reluctance torque constant identified / kT_reluct ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [mH]
1000.00 [mH]
0.00 [mH]
p3028
MotId reluctance force constant identified / kT_reluct ident
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [mH]
1000.00 [mH]
0.00 [mH]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1333
SINAMICS parameters
3.2 SINAMICS parameters
p3030
ChId factor plane adaptation positive / ChId pl_adpt pos
HLA
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.00 [%]
200.00 [%]
100.00 [%]
p3030
MotId angular commutation offset identified / Ang_com offset
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-180.00 [°]
180.00 [°]
0.00 [°]
p3031
ChId factor plane adaptation negative / ChId pl_adpt neg
HLA
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10 [%]
200 [%]
100 [%]
p3031
MotId encoder inversion actual value identified / EncInvActV ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p3031
MotId encoder inversion actual value identified / EncInvActV ident
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p3032
MotId: flux characteristic coefficient K01 identified / Psid_mod K01 ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1334
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3033
ChId transition point compensation Q1 positive zero range / ChId tr pt Q1 pos
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.01 [%]
95.00 [%]
0.01 [%]
p3033
MotId: flux characteristic coefficient K02 identified / Psid_mod K02 ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100000.0000
100000.0000
0.0000
p3034
ChID transition point compensation U1 positive zero range / ChId tr pt U1 pos
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
95.00 [%]
0.00 [%]
p3034
MotId: flux characteristic coefficient K03 identified / Psid_mod K03 ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100000.0000
100000.0000
0.0000
p3035
ChID transition point compensation rounding 1 pos. zero range / ChId TrPtRnd 1 pos
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
30.00 [%]
0.00 [%]
p3035
MotId: quadrature flux model coefficient K01 identified / Psiq_mod K01 ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0000
5.0000
0.0000
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1335
SINAMICS parameters
3.2 SINAMICS parameters
p3036
ChId transition point compensation Q1 negative zero range / ChId tr pt Q1 neg
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.01 [%]
95.00 [%]
0.01 [%]
p3036
MotId: quadrature flux model coefficient K02 identified / Psiq_mod K02 ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3037
ChId transition point compensation U1 negative zero range / ChId tr pt U1 neg
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
95.00 [%]
0.00 [%]
p3037
MotId: quadrature flux model coefficient K03 identified / Psiq_mod K03 ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3038
ChId transition point compensation rounding 1 neg. zero range / ChId TrPtRnd 1 neg
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
30.00 [%]
0.00 [%]
p3038
MotId: quadrature flux model coefficient K04 identified / Psiq_mod K04 ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1336
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3039
ChId transition point compensation Q2 positive / ChId tr pt Q2 pos
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.02 [%]
95.00 [%]
10.00 [%]
p3040
ChId transition point compensation U2 positive / ChId tr pt U2 pos
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
95.00 [%]
10.00 [%]
p3041
ChId transition point compensation rounding 2 positive / ChId TrPtRnd 2 pos
HLA
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
30.00 [%]
0.00 [%]
p3041
MotId moment of inertia identified / M_inertia ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: 25_1
Unit selection: p0100
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000000 [kgm²]
100000.000000 [kgm²]
0.000000 [kgm²]
p3041
MotId motor mass identified / Mot mass ident
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: 27_1
Unit selection: p0100
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000000 [kg]
10000.000000 [kg]
0.000000 [kg]
p3042
ChId transition point compensation Q2 negative / ChId tr pt Q2 neg
HLA
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
95.00 [%]
0.00 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1337
SINAMICS parameters
3.2 SINAMICS parameters
p3042
MotId load moment of inertia identified / Load m_inert ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: 25_1
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kgm²]
- [kgm²]
- [kgm²]
p3042
MotId load mass identified / Load mass ident
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: 27_1
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kg]
- [kg]
- [kg]
p3043
ChId transition point compensation U2 negative / ChId tr pt U2 neg
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
95.00 [%]
0.00 [%]
p3044
ChId transition point compensation rounding 2 negative / ChId TrPtRnd 2 neg
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
30.00 [%]
0.00 [%]
p3045
ChId transition point compensation Q3 positive saturation / ChId TrPt Q3 pos S
HLA
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.20 [%]
100.00 [%]
100.00 [%]
p3045
MotId force characteristic kT1 identified / kT1 ident
SERVO (Ext M_ctrl, Lin),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Ext M_ctrl,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
Lin)
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-340.28235E36 [N/Arms]
340.28235E36 [N/Arms]
0.00 [N/Arms]
Machine data and parameters
1338
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3045
MotId torque characteristic kT1 identified / kT1 ident
SERVO (Ext M_ctrl),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Ext M_ctrl) Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-340.28235E36 [Nm/A]
340.28235E36 [Nm/A]
0.00 [Nm/A]
p3046
ChId transition point compensation U3 positive saturation / ChId TrPt U3 pos S
HLA
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.20 [%]
100.00 [%]
100.00 [%]
p3046
MotId force characteristic kT3 identified / kT3 ident
SERVO (Ext M_ctrl, Lin),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Ext M_ctrl,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
Lin)
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3046
MotId torque characteristic kT3 identified / kT3 ident
SERVO (Ext M_ctrl),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Ext M_ctrl) Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3047
ChId transition point compensation Q3 negative saturation / ChId TrPt Q3 neg S
HLA
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.20 [%]
100.00 [%]
100.00 [%]
p3047
MotId force characteristic kT5 identified / kT5 ident
SERVO (Ext M_ctrl, Lin),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Ext M_ctrl,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
Lin)
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1339
SINAMICS parameters
3.2 SINAMICS parameters
p3047
MotId torque characteristic kT5 identified / kT5 ident
SERVO (Ext M_ctrl),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Ext M_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3048
ChId transition point compensation U3 negative saturation / ChId TrPt U3 neg S
HLA
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.20 [%]
100.00 [%]
100.00 [%]
p3048
MotId force characteristic kT7 identified / kT7 ident
SERVO (Ext M_ctrl, Lin),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Ext M_ctrl,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
Lin)
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3048
MotId torque characteristic kT7 identified / kT7 ident
SERVO (Ext M_ctrl),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Ext M_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3049[0...n]
MotId Speed at start of field weakening identified / ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [rpm]
210000.00000 [rpm]
0.00000 [rpm]
p3049[0...n]
MotId Speed at start of field weakening identified / v_Fieldweak ident
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [m/min]
1300.00000 [m/min]
0.00000 [m/min]
Machine data and parameters
1340
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3050[0...n]
MotorId stator resistance identified / R_stator ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: 16_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [ohm]
2000.00000 [ohm]
0.00000 [ohm]
p3054[0...n]
MotId rotor resistance identified / R_rotor ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: 16_1
Unit selection: p0349
Not for motor type: PMSM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [ohm]
300.00000 [ohm]
0.00000 [ohm]
p3056[0...n]
MotId stator leakage inductance identified / L_stator leak
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: 15_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [mH]
1000.00000 [mH]
0.00000 [mH]
p3058[0...n]
MotId rotor leakage inductance identified / L_rotor leak
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: 15_1
Unit selection: p0349
Not for motor type: PMSM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [mH]
1000.00000 [mH]
0.00000 [mH]
p3060[0...n]
MotId magnetizing inductance identified / MotId Lh ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: 15_1
Unit selection: p0349
Not for motor type: PMSM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [mH]
10000.00000 [mH]
0.00000 [mH]
p3065
MotID periodic position error amplitude 1 / MotID pos err amp1
SERVO
Can be changed: T, U
Calculated: -
Access level: 3
(Cog_M_comp),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC
P-Group: Motor identification
Unit group: -
Unit selection: -
(Cog_M_comp)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0
20000.0
0.0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1341
SINAMICS parameters
3.2 SINAMICS parameters
p3066
MotID periodic position error angle 1 / MotID pos err ang1
SERVO
Can be changed: T, U
Calculated: -
Access level: 3
(Cog_M_comp),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC
P-Group: Motor identification
Unit group: -
Unit selection: -
(Cog_M_comp)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-180.00 [°]
180.00 [°]
0.00 [°]
p3067
MotID periodic position error amplitude 2 / MotID pos err amp2
SERVO
Can be changed: T, U
Calculated: -
Access level: 3
(Cog_M_comp),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC
P-Group: -
Unit group: -
Unit selection: -
(Cog_M_comp)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0
20000.0
0.0
p3068
MotID periodic position error angle 2 / MotID pos err ang2
SERVO
Can be changed: T, U
Calculated: -
Access level: 3
(Cog_M_comp),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC
P-Group: Motor identification
Unit group: -
Unit selection: -
(Cog_M_comp)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-180.00 [°]
180.00 [°]
0.00 [°]
p3070
MotId voltage emulation error final value identified / U_err final ident
SERVO (Ext M_ctrl),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Ext M_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [V]
100.000 [V]
0.000 [V]
p3071
MotId voltage emulation error current offset identified / U_error I_offset
SERVO (Ext M_ctrl),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Ext M_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [A]
100.000 [A]
0.000 [A]
p3072
MotId voltage emulation error semiconductor voltage identified / U_error_semi ident
SERVO (Ext M_ctrl),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Ext M_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10.000 [V]
10.000 [V]
0.000 [V]
Machine data and parameters
1342
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3075
ChId velocity controller loop gain / ChId v loop_gain
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [mm/Vmin]
20000.0 [mm/Vmin]
0.0 [mm/Vmin]
p3080
MotId flux controller P gain identified / Flux ctrl Kp ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [A/Vs]
999999.0 [A/Vs]
0.0 [A/Vs]
p3081
MotId flux controller integral time identified / Flux ctrl Tn ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
10000 [ms]
0 [ms]
p3082
MotId current controller P gain identified / I_ctrl Kp ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: 18_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [V/A]
100000.000 [V/A]
0.000 [V/A]
p3083
ChId maximum positive velocity / ChId v_max pos
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [m/min]
1300.000 [m/min]
0.000 [m/min]
p3083
MotId current controller integral time identified / I_ctrl Tn ident
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
1000.00 [ms]
0.00 [ms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1343
SINAMICS parameters
3.2 SINAMICS parameters
p3086
ChId maximum negative velocity / ChId v_max neg
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1300.000 [m/min]
0.000 [m/min]
0.000 [m/min]
p3088
MotId Motor model changeover speed operation with encoder ident. / MotMod
n_chgSnsorl
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [rpm]
210000.00000 [rpm]
0.00000 [rpm]
p3088
MotId Motor model changeover vel. operat. with encod. ident. / v_chg Ident encod
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [m/min]
1300.00000 [m/min]
0.00000 [m/min]
p3089[0...n]
MotId voltage-time area identified for flying restart / FlyRest vT ident
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [mVs]
5000 [mVs]
0 [mVs]
p3090[0...n]
PolID elasticity-based configuration / PolID el config
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: Unsigned16
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p3091[0...n]
PolID elasticity-based ramp time / PolID el t_ramp
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
1000.0 [ms]
250.0 [ms]
Machine data and parameters
1344
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3092[0...n]
PolID elasticity-based wait time / PolID el t_wait
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
1000.0 [ms]
100.0 [ms]
p3093[0...n]
PolID elasticity-based measurement number / PolID el meas
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
6
56
12
p3094[0...n]
PolID elasticity-based deflection expected / PolID el defl exp
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0000 [°]
90.0000 [°]
0.0030 [°]
p3094[0...n]
PolID elasticity-based deflection expected / PolID el defl exp
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0000 [mm]
90.0000 [mm]
0.0030 [mm]
p3095[0...n]
PolID elasticity-based deflection permissible / PolID el defl exp
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0000 [°]
90.0000 [°]
1.0000 [°]
p3095[0...n]
PolID elasticity-based deflection permissible / PolID el defl exp
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0000 [mm]
90.0000 [mm]
1.0000 [mm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1345
SINAMICS parameters
3.2 SINAMICS parameters
p3096[0...n]
PolID elasticity-based current / PolID el curr
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [Arms]
20000.000 [Arms]
0.000 [Arms]
r3097.0...31
BO: PolID elasticity-based status / PolID el status
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3100
RTC time stamp mode / RTC t_stamp mode
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
2
p3101[0...1]
Setting UTC time / Set UTC time
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
0
r3102[0...1]
Displaying UTC time / Display UTC time
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3103
UTC synchronization process / UTC sync_process
CU_S_AC_PN,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
99
0
Machine data and parameters
1346
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3103
UTC synchronization process / UTC sync_process
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_DP
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
p3104
BI: UTC PING synchronization / UTC PING sync
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p3105[0...3]
NTP server IP address / NTP IP addr
CU_S_AC_PN,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
0
p3105[0...3]
NTP server IP address / NTP IP addr
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_DP
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
0
p3106
NTP time zone / Time zone
CU_S_AC_PN,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
38
14
p3106
NTP time zone / Time zone
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_DP
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
38
14
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1347
SINAMICS parameters
3.2 SINAMICS parameters
r3107[0...3]
UTC synchronization time out of tolerance / UTC t_sync out tol
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3108[0...1]
UTC synchronization deviation / UTC sync_dev
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3109
UTC synchronization tolerance / UTC sync tol
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
10000 [ms]
100 [ms]
p3110
External fault 3 switch-on delay / Ext fault 3 t_on
All objects
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2546
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
0 [ms]
p3111
BI: External fault 3 enable / Ext fault 3 enab
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2546
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HUB, TB30, TM120,
Not for motor type: -
Scaling: -
Expert list: 1
TM15, TM150,
Min:
Max:
Factory setting:
TM15DI_DO, TM17,
-
-
1
TM31, TM54F_MA,
TM54F_SL
p3111[0...n]
BI: External fault 3 enable / Ext fault 3 enab
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: -
SERVO_AC, TM41,
P-Group: Messages
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
1348
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3112
BI: External fault 3 enable negated / Ext flt 3 enab neg
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2546
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HUB, TB30, TM120,
Not for motor type: -
Scaling: -
Expert list: 1
TM15, TM150,
Min:
Max:
Factory setting:
TM15DI_DO, TM17,
-
-
0
TM31, TM54F_MA,
TM54F_SL
p3112[0...n]
BI: External fault 3 enable negated / Ext flt 3 enab neg
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: -
SERVO_AC, TM41,
P-Group: Messages
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r3113.0...15
CO/BO: NAMUR message bit bar / NAMUR bit bar
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3114.9...11
CO/BO: Messages status word global / Msg ZSW global
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3115[0...63]
Fault drive object initiating / Flt DO initiating
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: -
Function diagram: 8050, 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3116
BI: Suppress automatic acknowledgment / Ackn suppress
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1349
SINAMICS parameters
3.2 SINAMICS parameters
p3117
Change safety message type / Chg SI msg type
CU_S_AC_DP,
Can be changed: C1(1)
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p3118[0...1]
Issue messages / Issue messages
All objects
Can be changed: T, U
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
r3120[0...63]
Component fault / Comp fault
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3121[0...63]
Component alarm / Comp alarm
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 8065
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3122[0...63]
Diagnostic attribute fault / Diag_attr fault
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3123[0...63]
Diagnostic attribute alarm / Diag_attr alarm
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 8065
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1350
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r3131
CO: Actual fault value / Act fault val
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: -
Function diagram: 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3132
CO: Actual component number / Comp_no act
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: -
Function diagram: 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3135
Suppress active fault / Supp act flt
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 4
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: 8060
SERVO_AC, TM41,
P-Group: Messages
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p3201[0...n]
Excitation current outside the tolerance threshold value / I_exc n Tol thr
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.1 [%]
100.0 [%]
10.0 [%]
p3201[0...n]
Excitation current outside the tolerance threshold value / I_exc n Tol thr
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.1 [%]
1000.0 [%]
9.0 [%]
p3201[0...n]
Excitation current outside the tolerance threshold value / I_exc n Tol thr
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.1 [%]
100.0 [%]
10.0 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1351
SINAMICS parameters
3.2 SINAMICS parameters
p3202[0...n]
Excitation current outside the tolerance hysteresis / I_exc n Tol hyst
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.1 [%]
100.0 [%]
10.0 [%]
p3202[0...n]
Excitation current outside the tolerance hysteresis / I_exc n Tol hyst
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.1 [%]
1000.0 [%]
9.0 [%]
p3202[0...n]
Excitation current outside the tolerance hysteresis / I_exc n Tol hyst
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.1 [%]
100.0 [%]
10.0 [%]
p3203[0...n]
Excitation current outside the tolerance delay time / I_exc n Tol t_del
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.0 [s]
10.0 [s]
1.0 [s]
p3203[0...n]
Excitation current outside the tolerance delay time / I_exc n Tol t_del
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [s]
10.0 [s]
1.0 [s]
p3204[0...n]
Flux outside the tolerance threshold value / Flux n tol thr
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.1 [%]
100.0 [%]
10.0 [%]
Machine data and parameters
1352
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3204[0...n]
Flux outside the tolerance threshold value / Flux n tol thr
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.1 [%]
1000.0 [%]
9.0 [%]
p3204[0...n]
Flux outside the tolerance threshold value / Flux n tol thr
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.1 [%]
100.0 [%]
10.0 [%]
p3205[0...n]
Flux outside the tolerance hysteresis / Flux n tol hyst
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.1 [%]
50.0 [%]
10.0 [%]
p3205[0...n]
Flux outside the tolerance hysteresis / Flux n tol hyst
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.1 [%]
1000.0 [%]
9.0 [%]
p3205[0...n]
Flux outside the tolerance hysteresis / Flux n tol hyst
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.1 [%]
50.0 [%]
10.0 [%]
p3206[0...n]
Flux outside tolerance delay time / Flux n tol t_del
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.0 [s]
10.0 [s]
5.0 [s]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1353
SINAMICS parameters
3.2 SINAMICS parameters
p3206[0...n]
Flux outside tolerance delay time / Flux n tol t_del
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [s]
10.0 [s]
5.0 [s]
p3207[0...n]
Zero current signal threshold value / I_0_sig thr
SERVO, SERVO_AC
Can be changed: T, U
Calculated:
Access level: 8
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.01 [Arms]
10000.00 [Arms]
1.00 [Arms]
p3207[0...n]
Zero current signal threshold value / I_0_sig thr
SERVO (Lin),
Can be changed: T, U
Calculated:
Access level: 8
SERVO_AC (Lin)
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.01 [Arms]
1000.00 [Arms]
9.00 [Arms]
p3207[0...n]
Zero current signal threshold value / I_0_sig thr
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated:
Access level: 3
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: 6_2
Unit selection: p0505
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.01 [Arms]
10000.00 [Arms]
1.00 [Arms]
p3208[0...n]
Zero current signal hysteresis / I_0_sig hyst
SERVO, SERVO_AC
Can be changed: T, U
Calculated:
Access level: 8
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.01 [Arms]
10000.00 [Arms]
1.00 [Arms]
Machine data and parameters
1354
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3208[0...n]
Zero current signal hysteresis / I_0_sig hyst
SERVO (Lin),
Can be changed: T, U
Calculated:
Access level: 8
SERVO_AC (Lin)
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.01 [Arms]
1000.00 [Arms]
9.00 [Arms]
p3208[0...n]
Zero current signal hysteresis / I_0_sig hyst
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated:
Access level: 3
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: 6_2
Unit selection: p0505
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.01 [Arms]
10000.00 [Arms]
1.00 [Arms]
p3209[0...n]
Zero current signal delay time / I_0_sig t_del
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [s]
10.00 [s]
0.02 [s]
p3209[0...n]
Zero current signal delay time / I_0_sig t_del
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [s]
10.00 [s]
0.02 [s]
p3233[0...n]
Torque actual value filter time constant / M_act_filt Tc
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: -
Unit selection: -
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000000 [ms]
0 [ms]
p3235
Phase failure signal motor monitoring time / Ph_fail t_mon
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 4
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
2000 [ms]
320 [ms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1355
SINAMICS parameters
3.2 SINAMICS parameters
p3236[0...n]
Speed threshold value 7 / n_thr val 7
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated:
Access level: 3
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 8012
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
3000.00 [rpm]
100.00 [rpm]
p3237[0...n]
Hysteresis speed 7 / n_hysteresis 7
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated:
Access level: 3
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 8012
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
200.00 [rpm]
2.00 [rpm]
p3238[0...n]
OFF-delay n_act_motor model = n_act external / t_del n_a = n_ext
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [s]
100.0 [s]
3.0 [s]
p3240[0...n]
CI: I2t input value signal source / I2t inp_val s_s
SERVO (Ext msg),
Can be changed: T
Calculated: -
Access level: 8
SERVO_AC (Ext msg)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 8022
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p3240[0...n]
CI: I2t input value signal source / I2t inp_val s_s
VECTOR (Ext msg),
Can be changed: T
Calculated: -
Access level: 4
VECTOR_AC (Ext msg)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 8022
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p3241[0...n]
Permissible I2t continuous value / Perm I2t cont val
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Ext msg)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8022
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.00 [%]
200.00 [%]
100.00 [%]
Machine data and parameters
1356
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3241[0...n]
Permissible I2t continuous value / Perm I2t cont val
VECTOR (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 4
VECTOR_AC (Ext msg)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8022
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.00 [%]
200.00 [%]
100.00 [%]
p3242[0...n]
I2t maximum duration / I2t max_dur
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Ext msg)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8022
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [s]
3600.00 [s]
0.00 [s]
p3242[0...n]
I2t maximum duration / I2t max_dur
VECTOR (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 4
VECTOR_AC (Ext msg)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8022
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [s]
3600.00 [s]
0.00 [s]
p3243[0...n]
I2t alarm threshold / I2t alarm thr
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Ext msg)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8022
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
99.90 [%]
50.00 [%]
p3243[0...n]
I2t alarm threshold / I2t alarm thr
VECTOR (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 4
VECTOR_AC (Ext msg)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8022
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
99.90 [%]
50.00 [%]
r3244
CO: Actual I2t integrator value / Act I2t integ_val
SERVO (Ext msg),
Can be changed: -
Calculated: -
Access level: 8
SERVO_AC (Ext msg)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8022
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1357
SINAMICS parameters
3.2 SINAMICS parameters
r3244
CO: Actual I2t integrator value / Act I2t integ_val
VECTOR (Ext msg),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (Ext msg)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8022
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p3290
Variable signaling function start / Var sig start
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: -
Function diagram: 5301
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0010 bin
p3291[0...2]
CI: Variable signaling function input signal signal source / Var sig inp s_s
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 5301
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p3292[0...2]
Variable signaling function signal source address / Var sig s_s addr
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 4
Data type: Unsigned32
Dynamic index: -
Function diagram: 5301
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p3293[0...2]
Variable signaling function signal source data type / Var sig s_s type
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 4
Data type: Integer16
Dynamic index: -
Function diagram: 5301
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
7
0
r3294.0...2
BO: Variable signaling function output signal / Var sig outp_sig
HLA, SERVO, SERVO_AC Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: -
Function diagram: 5301
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1358
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3295[0...2]
Variable signaling function threshold value / Var sig thr_val
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5301
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-340.28235E36
340.28235E36
0.000
p3296[0...2]
Variable signaling function hysteresis / Var sig hyst
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5301
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
340.28235E36
0.000
p3297[0...2]
Variable signaling function pickup delay / Var sig t_pickup
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 5301
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
10000 [ms]
0 [ms]
p3298[0...2]
Variable signaling function dropout delay / Var sig t_dropout
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 5301
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
10000 [ms]
0 [ms]
p3299[0...2]
Variable signaling function sampling time / Var sig t_samp
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5301
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.000 [ms]
4.000 [ms]
4.000 [ms]
p3310[0...n]
Efficiency optimization 2 flux setpoint weighting / Flux set weight
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
100.0 [%]
100.0 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1359
SINAMICS parameters
3.2 SINAMICS parameters
r3311[0...4]
Efficiency optimization 2 power losses flux-dependent / P_loss flux-depend
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 8
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 14_6
Unit selection: p0100
Not for motor type: PMSM, SESM, REL, RESM
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r3312[0...7]
Efficiency optimization 2 power losses according to loss types / P_loss acc to type
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 14_6
Unit selection: p0100
Not for motor type: PMSM, SESM, REL, RESM
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r3313
Efficiency optimization 2 optimum flux / Optimum flux
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6722, 6837
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p3314[0...n]
Efficiency optimization 2 flux calculation clearance / Flux calc clear
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
2.0 [%]
100.0 [%]
5.0 [%]
p3315[0...n]
Efficiency optimization 2 minimum flux limit value / Min flux lim val
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6722, 6837
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
200.0 [%]
50.0 [%]
p3316[0...n]
Efficiency optimization 2 maximum flux limit value / Max flux lim val
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6722, 6837
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
200.0 [%]
110.0 [%]
Machine data and parameters
1360
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3317[0...n]
Efficiency optimization 2 input values smoothing time constant / Input_values Tc
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
16 [ms]
10000 [ms]
100 [ms]
p3320[0...n]
Fluid flow machine power point 1 / Fluid_mach P1
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
25.00
p3321[0...n]
Fluid flow machine speed point 1 / Fluid_mach n1
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
0.00
p3322[0...n]
Fluid flow machine power point 2 / Fluid_mach P2
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
50.00
p3323[0...n]
Fluid flow machine speed point 2 / Fluid_mach n2
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
25.00
p3324[0...n]
Fluid flow machine power point 3 / Fluid_mach P3
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
77.00
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1361
SINAMICS parameters
3.2 SINAMICS parameters
p3325[0...n]
Fluid flow machine speed point 3 / Fluid_mach n3
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
50.00
p3326[0...n]
Fluid flow machine power point 4 / Fluid_mach P4
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
92.00
p3327[0...n]
Fluid flow machine speed point 4 / Fluid_mach n4
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
75.00
p3328[0...n]
Fluid flow machine power point 5 / Fluid_mach P5
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
100.00
p3329[0...n]
Fluid flow machine speed point 5 / Fluid_mach n5
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
100.00
p3370[0...n]
Pulse technique configuration / Pulse config
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 4
VECTOR_AC (n/M)
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
Machine data and parameters
1362
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3371[0...n]
Pulse technique excitation starting point 1 / Pulse excit pt 1
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
20000.00 [Arms]
0.00 [Arms]
p3372[0...n]
Pulse technique excitation starting point 2 / Pulse excit pt 2
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
20000.00 [Arms]
0.00 [Arms]
p3373[0...n]
Pulse technique excitation adaptation / Pulse excit scale
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [%]
1000 [%]
100 [%]
r3374
CO: Pulse technique excitation actual / Pulse excit actual
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mVs]
- [mVs]
- [mVs]
r3375[0...5]
CO: Pulse technique response raw values / PulsTecRespRawVal
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
Not for motor type: ASM, SESM, REL
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r3376[0...2]
Pulse technique model parameters / Pulse model
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1363
SINAMICS parameters
3.2 SINAMICS parameters
r3377[0...2]
Pulse technique signals / Pulse signals
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3400
Infeed configuration word / INF config_word
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 1010 bin
r3402
Infeed internal state / INF status int
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: 8732, 8832,
8932
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
12
-
r3402
Infeed status internal BIC / INF status int
B_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: 8932
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
-
r3404.1...6
CO/BO: Infeed control word / INF STW
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3405.0...7
CO/BO: Infeed status word / Inf ZSW
A_INF, R_INF, S_INF,
Can be changed: -
Calculated: -
Access level: 2
SERVO (Tech_ctrl),
Data type: Unsigned16
Dynamic index: -
Function diagram: 8828, 8928
SERVO_AC (Tech_ctrl)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1364
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r3405.1...8
CO/BO: Status word DC link control / ZSW Vdc_ctrl
VECTOR (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 2
VECTOR_AC (Tech_ctrl)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3405.7
CO/BO: Infeed status word / Inf ZSW
B_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3408
Infeed line voltage setting / INF U_line_mode
A_INF, R_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p3408
Infeed line voltage setting / INF U_line_mode
S_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p3409
Infeed line frequency setting / INF f_line_mode
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
1
p3410
Infeed identification method / INF ID_type
A_INF, R_INF, S_INF
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
5
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1365
SINAMICS parameters
3.2 SINAMICS parameters
r3411[0...1]
Infeed identified inductance / INF L ident
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r3412[0...1]
Infeed DC link capacitance identified / INF C_DClink ident
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mF]
- [mF]
- [mF]
r3413
Infeed control dead time identified / INF t_dead ident
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3414[0...1]
Infeed line supply inductance identified / INF L_line ident
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
p3415[0...1]
Infeed excitation current L identification / INF I_exc L-ID
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.00 [%]
75.00 [%]
20.00 [%]
p3416
Infeed excitation amplitude C identification / INF exc_amp C_ID
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.10 [%]
20.00 [%]
2.00 [%]
Machine data and parameters
1366
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3417
Infeed excitation frequency C identification / INF f_exc C_ID
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.00 [Hz]
200.00 [Hz]
50.00 [Hz]
p3418
Infeed excitation frequency dead time identification / INF f_exc t_ID
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.00 [Hz]
2000.00 [Hz]
1900.00 [Hz]
p3421
Infeed inductance / INF L
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001 [mH]
2000.000 [mH]
1.000 [mH]
p3422
Infeed DC link capacitance / INF C_DCL
A_INF, R_INF, S_INF,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC (Tech_ctrl)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.20 [mF]
2000.00 [mF]
2.00 [mF]
p3422
DC link capacitance total / C_DC tot
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.20 [mF]
2000.00 [mF]
2.00 [mF]
p3424
Infeed line supply inductance / INF L_line
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001 [mH]
1000.000 [mH]
0.001 [mH]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1367
SINAMICS parameters
3.2 SINAMICS parameters
p3425[0...5]
Infeed control loop parameter scaling / INF par scal
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.00 [%]
1000.00 [%]
100.00 [%]
r3435[0...9]
Smart Mode end of sector PWM on times / SLM end PWM t_on
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [µs]
- [µs]
- [µs]
r3436[0...9]
Smart Mode end of sector PWM off times / SLM end PWM t_off
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [µs]
- [µs]
- [µs]
p3440
Smart Mode configuration / Smart Mode config
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0001 bin
p3441[0...1]
Smart Mode Vdc ctrl Kp/Tn / SLM Vdc_ctrl Kp/Tn
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
1000.00 [%]
100.00 [%]
p3442[0...1]
Smart Mode smoothing times / SLM t_smth
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
20.00 [ms]
[0] 0.25 [ms]
[1] 1.00 [ms]
Machine data and parameters
1368
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3443[0...1]
Smart Mode line commutation current threshold values / SLM line com I_thr
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
1000.00 [%]
[0] 100.00 [%]
[1] 200.00 [%]
p3444[0...3]
Smart Mode voltages / SLM voltages
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
105.00 [%]
[0] 90.00 [%]
[1] 100.50 [%]
[2] 70.00 [%]
[3] 70.00 [%]
r3445[0...1]
Smart Mode voltages display / SLM voltages disp
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 5_2
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r3446[0...2]
Smart Mode currents / SLM currents
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 6_4
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r3447
Smart Mode OFF angle / SLM phi_OFF
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2005
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1369
SINAMICS parameters
3.2 SINAMICS parameters
p3448[0...1]
Smart Mode inductance/DC link capacitance / SLM L/C
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.00 [%]
10000.00 [%]
[0] 110.00 [%]
[1] 100.00 [%]
r3452
Infeed PLL status / INF PLL status
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 4
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
7
-
p3457[0...2]
Infeed PLL supplementary settings / INF PLL suppl_set
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
300.00 [%]
0.00 [%]
p3458[0...1]
Infeed PLL smoothing time / INF PLL t_smth
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.0 [ms]
1000.0 [ms]
[0] 23.1 [ms]
[1] 9.1 [ms]
r3460
Infeed PLL system deviation / INF PLL SysDev
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
Machine data and parameters
1370
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r3461
Infeed PLL system deviation after filtering / INF PLL SysDev sm
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
p3462[0...2]
Infeed phase failure detection times / INF ph_fail_det t
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [s]
10000.00 [s]
[0] 0.00 [s]
[1] 3.00 [s]
[2] 60.00 [s]
p3463
Infeed phase failure detection line supply angle change / INF ph_fail phi
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-180.0 [°]
180.0 [°]
15.0 [°]
p3465[0...5]
Infeed current symmetry monitoring thresholds / INF I_sym thr
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
200.0 [%]
[0] 60.0 [%]
[1] 100.0 [%]
[2] 25.0 [%]
[3] 90.0 [%]
[4] 100.0 [%]
[5] 12.5 [%]
r3466[0...2]
CO: Infeed phase current rms value smoothed / INF I_ph rms smth
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1371
SINAMICS parameters
3.2 SINAMICS parameters
r3467[0...3]
CO: Infeed current alpha/beta / INF I a/b
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r3468[0...5]
CO: Infeed voltage alpha/beta / INF U a/b
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p3469[0...n]
Latch delay time correction, zero crossover detection / t_latch corr PLL
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10000.0 [µs]
10000.0 [µs]
0.0 [µs]
r3470
CO: Infeed active current filter / INF I_act filter
A_INF, R_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r3470
CO: Infeed active current filter / INF I_act filter
S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 0
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r3471
CO: Infeed reactive current filter / INF I_react filt
A_INF, R_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
Machine data and parameters
1372
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r3471
CO: Infeed reactive current filter / INF I_react filt
S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 0
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
p3472[0...4]
Line supply PLL line supply voltage smoothing time / Line PLL U_l t_sm
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.0 [ms]
30000.0 [ms]
[0] 200.0 [ms]
[1] 100.0 [ms]
[2] 5000.0 [ms]
[3] 8.0 [ms]
[4] 8.0 [ms]
p3473[0...3]
CI: cos phi display current signal source / cos phi I s_s
A_INF (cos phi), R_INF
Can be changed: T
Calculated: -
Access level: 3
(cos phi)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 8951
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 3467[0]
[1] 3467[1]
[2] 3467[2]
[3] 3467[3]
p3474[0...3]
CI: cos phi display voltage signal source / cos phi U s_s
A_INF (cos phi), R_INF
Can be changed: T
Calculated: -
Access level: 3
(cos phi)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 8951
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 3468[0]
[1] 3468[1]
[2] 3468[2]
[3] 3468[3]
p3475[0...1]
cos phi display configuration / cos phi config
A_INF (cos phi), R_INF
Can be changed: T
Calculated: -
Access level: 2
(cos phi)
Data type: Unsigned16
Dynamic index: -
Function diagram: 8951
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1373
SINAMICS parameters
3.2 SINAMICS parameters
p3476[0...1]
cos phi display smoothing time / cos phi t_smth
A_INF (cos phi), R_INF
Can be changed: T, U
Calculated: -
Access level: 3
(cos phi)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8951
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
2000.00 [ms]
200.00 [ms]
r3477[0...1]
CO: cos phi display actual value sign / cos phi ActV sign
A_INF (cos phi), R_INF
Can be changed: -
Calculated: -
Access level: 3
(cos phi)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8951
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r3478[0...1]
CO: cos phi display absolute actual value / cos phi ActV abs
A_INF (cos phi), R_INF
Can be changed: -
Calculated: -
Access level: 3
(cos phi)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8951
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3479[0...1]
cos phi display current measurement dead time / cos phi I_m t_dead
A_INF (cos phi), R_INF
Can be changed: T, U
Calculated: -
Access level: 3
(cos phi)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10000.000 [µs]
10000.000 [µs]
620.000 [µs]
p3480
Infeed modulation depth limit / INF mod_depth lim
A_INF, R_INF
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.0 [%]
110.0 [%]
97.0 [%]
p3480
Infeed modulation depth limit / INF mod_depth lim
S_INF
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
50.0 [%]
110.0 [%]
97.0 [%]
Machine data and parameters
1374
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3481
Infeed standby controller dynamic response / INF resp_ctrl dyn
A_INF, R_INF
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
1000.0 [ms]
7.5 [ms]
p3481
Infeed standby controller dynamic response / INF resp_ctrl dyn
S_INF
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.0 [ms]
1000.0 [ms]
7.5 [ms]
r3485
Infeed standby controller output / INF res_ctrl outp
A_INF, R_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r3485
Infeed standby controller output / INF res_ctrl outp
S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 0
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p3490
Infeed delay time OFF1 command / INF t_del OFF1
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 2
S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8732, 8832,
8932
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
1000000.0 [ms]
0.0 [ms]
p3491
Infeed I-offset measurement monitoring time / INF I_offs t_mon
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8832, 8932
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
65000 [ms]
2000 [ms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1375
SINAMICS parameters
3.2 SINAMICS parameters
p3492
Infeed, line supply undervoltage delay time / INF U_line t_del
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [s]
300 [s]
0 [s]
r3496[0...1]
CO: cos phi display actual value / cos phi disp ActV
A_INF (cos phi), R_INF
Can be changed: -
Calculated: -
Access level: 3
(cos phi)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8951
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p3508
Infeed step-up factor maximum / Step-up factor max
A_INF, R_INF
Can be changed: T
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.60
3.00
1.60
p3508
Infeed step-up factor maximum / Step-up factor max
S_INF
Can be changed: T
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1.60
3.00
1.60
p3510
Infeed DC link voltage setpoint / INF Vdc set
A_INF, R_INF, SERVO
Can be changed: T, U
Calculated: -
Access level: 2
(Tech_ctrl), SERVO_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8910, 8940
(Tech_ctrl)
P-Group: Closed-loop control
Unit group: 5_2
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
100.00 [V]
1600.00 [V]
600.00 [V]
p3510
DC link voltage setpoint / Vdc set
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7960
P-Group: Closed-loop control
Unit group: 5_2
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
100.00 [V]
1600.00 [V]
600.00 [V]
Machine data and parameters
1376
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3510
Infeed DC link voltage setpoint / INF Vdc set
S_INF
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8910, 8940
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
100.00 [V]
1600.00 [V]
600.00 [V]
p3511
CI: Infeed DC link voltage supplementary setpoint / INF Vdc Z_set
A_INF, R_INF, SERVO
Can be changed: T
Calculated: -
Access level: 3
(Tech_ctrl), SERVO_AC
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 8940
(Tech_ctrl)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p3511
CI: DC link voltage supplementary setpoint / Vdc Z_set
VECTOR (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (Tech_ctrl)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7960
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p3511
CI: Infeed DC link voltage supplementary setpoint / INF Vdc Z_set
S_INF
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
p3513
BI: Voltage-controlled operation inhibit / U_ctrl op inhib
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 8940
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p3513
BI: Voltage-controlled operation inhibit / U_ctrl op inhib
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (Tech_ctrl)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 7960
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1377
SINAMICS parameters
3.2 SINAMICS parameters
p3513
BI: Voltage-controlled operation inhibit / U_ctrl op inhib
A_INF, R_INF
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 8940
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p3513
BI: Voltage-controlled operation inhibit / U_ctrl op inhib
S_INF
Can be changed: T, U
Calculated: -
Access level: 8
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 8940
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
p3514
Infeed supplementary active current steady-state / INF I_sup_eff stat
A_INF, R_INF
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-2000.00 [Arms]
2000.00 [Arms]
0.00 [Arms]
p3514
Infeed supplementary active current steady-state / INF I_sup_eff stat
S_INF
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-2000.00 [Arms]
2000.00 [Arms]
0.00 [Arms]
p3515
CI: Infeed supplementary active current / INF I_suppl act
A_INF, R_INF
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p3515
CI: Infeed supplementary active current / INF I_suppl act
S_INF
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1378
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3516
Infeed current distribution factor / INF I_dist_factor
A_INF, R_INF
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
100.00 [%]
100.00 [%]
p3516
Infeed current distribution factor / INF I_dist_factor
S_INF
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [%]
100.00 [%]
100.00 [%]
r3517
CO: Infeed active current controller unlimited setpoint / INF I_act ctrl set
A_INF, R_INF, SERVO
Can be changed: -
Calculated: -
Access level: 3
(Tech_ctrl), SERVO_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940
(Tech_ctrl)
P-Group: Closed-loop control
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r3517
CO: DC link controller active current setpoint / Vdc I_act set
VECTOR (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6220, 7960
P-Group: Closed-loop control
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r3517
CO: Infeed active current controller unlimited setpoint / INF I_act ctrl set
S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940
P-Group: Closed-loop control
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 0
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
p3519[0...3]
CI: Infeed precontrol power (scaled) / INF prectrl P scal
A_INF, R_INF, SERVO
Can be changed: T
Calculated: -
Access level: 2
(Tech_ctrl), SERVO_AC
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
(Tech_ctrl)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1379
SINAMICS parameters
3.2 SINAMICS parameters
p3519[0...3]
CI: DC link precontrol power (scaled) / Vdc prectrl P scal
VECTOR (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 2
VECTOR_AC (Tech_ctrl)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p3519[0...3]
CI: Infeed precontrol power (scaled) / INF prectrl P scal
S_INF
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: r2004
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
p3520[0...3]
CI: Infeed precontrol power (not scaled) / INF prctr P n Scal
A_INF, R_INF, SERVO
Can be changed: T
Calculated: -
Access level: 2
(Tech_ctrl), SERVO_AC
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
(Tech_ctrl)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p3520[0...3]
CI: DC link precontrol power (not scaled) / Vdc prectrl P
VECTOR (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 2
VECTOR_AC (Tech_ctrl)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7960
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p3520[0...3]
CI: Infeed precontrol power (not scaled) / INF prctr P n Scal
S_INF
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
p3521[0...3]
Infeed precontrol power scaling / INF prectrl P scal
A_INF, R_INF, SERVO
Can be changed: T, U
Calculated: -
Access level: 2
(Tech_ctrl), SERVO_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(Tech_ctrl)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-100000.00000 [%]
100000.00000 [%]
100.00000 [%]
Machine data and parameters
1380
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p3521[0...3]
DC link precontrol power scaling / Vdc prectrl P scal
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7960
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-100000.00000 [%]
100000.00000 [%]
100.00000 [%]
p3521[0...3]
Infeed precontrol power scaling / INF prectrl P scal
S_INF
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 0
Min:
Max:
Factory setting:
-100000.00000 [%]
100000.00000 [%]
100.00000 [%]
r3522[0...4]
CO: DC link voltage control precontrol display / Vdc_ctr prectr dis
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 4
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7960
VECTOR (Tech_ctrl),
P-Group: Closed-loop control
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r3522
CO: Infeed precontrol power display / INF prectrl P_disp
A_INF, R_INF
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r3522
CO: Infeed precontrol power display / INF prectrl P_disp
S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
p3523[0...3]
Infeed precontrol power smoothing / INF prectrl P smth
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
0 [ms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1381
|