SINAMICS parameters
3.2 SINAMICS parameters
p2107[0...n]
BI: External fault 2 / External fault 2
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2546
SERVO_AC, TM41,
P-Group: Messages
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p2108
BI: External fault 3 / External fault 3
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HUB, TB30, TM120,
Not for motor type: -
Scaling: -
Expert list: 1
TM15, TM150,
Min:
Max:
Factory setting:
TM15DI_DO, TM17,
-
-
1
TM31, TM54F_MA,
TM54F_SL
p2108[0...n]
BI: External fault 3 / External fault 3
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2546
SERVO_AC, TM41,
P-Group: Messages
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
r2109[0...63]
Fault time removed in milliseconds / t_flt rem ms
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 8050, 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
r2110[0...63]
Alarm number / Alarm number
All objects
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 8065
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2111
Alarm counter / Alarm counter
All objects
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 8050, 8065
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
Machine data and parameters
1244
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2112
BI: External alarm 1 / External alarm 1
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HUB, TB30, TM120,
Not for motor type: -
Scaling: -
Expert list: 1
TM15, TM150,
Min:
Max:
Factory setting:
TM15DI_DO, TM17,
-
-
1
TM31, TM54F_MA,
TM54F_SL
p2112[0...n]
BI: External alarm 1 / External alarm 1
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2546
SERVO_AC, TM41,
P-Group: Messages
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
r2114[0...1]
System runtime total / Sys runtime tot
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2116
BI: External alarm 2 / External alarm 2
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HUB, TB30, TM120,
Not for motor type: -
Scaling: -
Expert list: 1
TM15, TM150,
Min:
Max:
Factory setting:
TM15DI_DO, TM17,
-
-
1
TM31, TM54F_MA,
TM54F_SL
p2116[0...n]
BI: External alarm 2 / External alarm 2
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2546
SERVO_AC, TM41,
P-Group: Messages
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1245
SINAMICS parameters
3.2 SINAMICS parameters
p2117
BI: External alarm 3 / External alarm 3
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HUB, TB30, TM120,
Not for motor type: -
Scaling: -
Expert list: 1
TM15, TM150,
Min:
Max:
Factory setting:
TM15DI_DO, TM17,
-
-
1
TM31, TM54F_MA,
TM54F_SL
p2117[0...n]
BI: External alarm 3 / External alarm 3
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2546
SERVO_AC, TM41,
P-Group: Messages
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p2118[0...19]
Change message type message number / Chg type msg_no
All objects
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 8050, 8075
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p2119[0...19]
Change message type type / Change type type
All objects
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 8050, 8075
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
3
1
r2120
CO: Sum of fault and alarm buffer changes / Sum buffer changed
All objects
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned16
Dynamic index: -
Function diagram: 8065
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2121
CO: Counter alarm buffer changes / A buff changed
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 8065
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1246
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2122[0...63]
Alarm code / Alarm code
All objects
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 8050, 8065
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2123[0...63]
Alarm time received in milliseconds / t_alarm recv ms
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 8050, 8065
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
r2124[0...63]
Alarm value / Alarm value
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: -
Function diagram: 8050, 8065
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2125[0...63]
Alarm time removed in milliseconds / t_alarm rem ms
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 8050, 8065
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
p2126[0...19]
Change acknowledge mode fault number / Chg ackn flt_no
All objects
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 8050, 8075
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p2127[0...19]
Change acknowledge mode mode / Chg ackn mode
All objects
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 8050, 8075
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
3
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1247
SINAMICS parameters
3.2 SINAMICS parameters
p2128[0...15]
Faults/alarms trigger selection / F/A trigger sel
All objects
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 8050, 8070
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
r2129.0...15
CO/BO: Faults/alarms trigger word / F/A trigger word
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 8070
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2130[0...63]
Fault time received in days / t_fault recv days
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2131
CO: Actual fault code / Act fault code
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2132
CO: Actual alarm code / Alarm code act
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 8065
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2133[0...63]
Fault value for float values / Fault val float
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1248
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2134[0...63]
Alarm value for float values / Alarm value float
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8065
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2135.0...15
CO/BO: Status word faults/alarms 2 / ZSW fault/alarm 2
All objects
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 2548
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2136[0...63]
Fault time removed in days / t_flt rem days
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2138.7...15
CO/BO: Control word faults/alarms / STW fault/alarm
All objects
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 2546
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2139.0...15
CO/BO: Status word faults/alarms 1 / ZSW fault/alarm 1
All objects
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 2548
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2140[0...n]
Hysteresis speed 2 / n_hysteresis 2
SERVO, SERVO_AC,
Can be changed: T, U
Calculated:
Access level: 3
VECTOR, VECTOR_AC
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 8010
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
300.00 [rpm]
90.00 [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1249
SINAMICS parameters
3.2 SINAMICS parameters
p2140[0...n]
Hysteresis velocity 2 / v_hysteresis 2
SERVO (Lin),
Can be changed: T, U
Calculated:
Access level: 3
SERVO_AC (Lin)
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
10.00 [m/min]
0.90 [m/min]
p2141[0...n]
Speed threshold 1 / n_thr val 1
SERVO, SERVO_AC,
Can be changed: T, U
Calculated:
Access level: 3
VECTOR, VECTOR_AC
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
5.00 [rpm]
p2141[0...n]
Velocity threshold value 1 / v_thr val 1
SERVO (Lin),
Can be changed: T, U
Calculated:
Access level: 3
SERVO_AC (Lin)
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
0.05 [m/min]
p2142[0...n]
Hysteresis speed 1 / n_hysteresis 1
SERVO, SERVO_AC,
Can be changed: T, U
Calculated:
Access level: 3
VECTOR, VECTOR_AC
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
300.00 [rpm]
2.00 [rpm]
p2142[0...n]
Hysteresis speed 1 / n_hysteresis 1
SERVO (Lin),
Can be changed: T, U
Calculated:
Access level: 3
SERVO_AC (Lin)
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
10.00 [m/min]
0.02 [m/min]
Machine data and parameters
1250
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2144[0...n]
BI: Motor stall monitoring enable (negated) / Mot stall enab neg
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 8012
VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r2145[0...63]
Alarm time received in days / t_alarm recv days
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 8065
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2146[0...63]
Alarm time removed in days / t_alarm rem days
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 8065
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2147
Delete fault buffer of all drive objects / Del fault buffer
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: 8060
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p2148[0...n]
BI: RFG active / RFG active
SERVO, SERVO_AC,
Can be changed: T, U
Calculated:
Access level: 3
VECTOR, VECTOR_AC
CALC_MOD_LIM_REF
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 8011
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2149[0...n]
Monitoring configuration / Mon config
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1251
SINAMICS parameters
3.2 SINAMICS parameters
p2149[0...n]
Monitoring configuration / Mon config
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0001 bin
p2150[0...n]
Hysteresis speed 3 / n_hysteresis 3
SERVO, SERVO_AC,
Can be changed: T, U
Calculated:
Access level: 3
VECTOR, VECTOR_AC
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010, 8011
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
300.00 [rpm]
2.00 [rpm]
p2150[0...n]
Hysteresis velocity 3 / v_hysteresis 3
SERVO (Lin),
Can be changed: T, U
Calculated:
Access level: 3
SERVO_AC (Lin)
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010, 8011
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
3.00 [m/min]
0.02 [m/min]
p2151[0...n]
CI: Speed setpoint for messages/signals / n_set for msg
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 8011
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
1438[0]
p2151[0...n]
CI: Velocity setpoint for messages/signals / v_set for msg
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 8011
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
1438[0]
p2151[0...n]
CI: Speed setpoint for messages/signals / n_set for msg
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 8011
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
1170[0]
Machine data and parameters
1252
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2153[0...n]
Velocity actual value filter time constant / v_ActV filt Tc
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000000 [ms]
0 [ms]
p2153[0...n]
Speed actual value filter time constant / n_ActV filt Tc
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000000 [ms]
0 [ms]
p2153[0...n]
Velocity actual value filter time constant / v_ActV filt Tc
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000000 [ms]
0 [ms]
p2154[0...n]
CI: Speed setpoint 2 / n_set 2
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 8010
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2154[0...n]
CI: Velocity setpoint 2 / v_set 2
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 8010
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2155[0...n]
Speed threshold 2 / n_thr val 2
SERVO, SERVO_AC
Can be changed: T, U
Calculated:
Access level: 3
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
900.00 [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1253
SINAMICS parameters
3.2 SINAMICS parameters
p2155[0...n]
Velocity threshold value 2 / v_thr val 2
SERVO (Lin),
Can be changed: T, U
Calculated:
Access level: 3
SERVO_AC (Lin)
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
9.00 [m/min]
p2155[0...n]
Speed threshold 2 / n_thr val 2
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated:
Access level: 3
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
900.00 [rpm]
p2156[0...n]
On-delay comparison value reached / t_on cmpr val rchd
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
10000.0 [ms]
0.0 [ms]
p2161[0...n]
Speed threshold 3 / n_thr val 3
SERVO, SERVO_AC
Can be changed: T, U
Calculated:
Access level: 3
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010, 8011
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
5.00 [rpm]
p2161[0...n]
Velocity threshold value 3 / v_thr val 3
SERVO (Lin),
Can be changed: T, U
Calculated:
Access level: 3
SERVO_AC (Lin)
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010, 8011
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
0.05 [m/min]
Machine data and parameters
1254
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2161[0...n]
Speed threshold 3 / n_thr val 3
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated:
Access level: 3
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010, 8011
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
5.00 [rpm]
p2162[0...n]
Hysteresis speed n_act > n_max / Hyst n_act>n_max
SERVO, SERVO_AC,
Can be changed: T, U
Calculated:
Access level: 2
VECTOR, VECTOR_AC
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
60000.00 [rpm]
0.00 [rpm]
p2162[0...n]
Hysteresis velocity v_act > v_max / Hyst v_act>v_max
HLA, SERVO (Lin),
Can be changed: T, U
Calculated:
Access level: 2
SERVO_AC (Lin)
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8010
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
6.00 [m/min]
p2163[0...n]
Velocity threshold value 4 / v_thr val 4
HLA
Can be changed: T, U
Calculated:
Access level: 2
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
0.90 [m/min]
p2163[0...n]
Speed threshold 4 / n_thr val 4
SERVO, SERVO_AC,
Can be changed: T, U
Calculated:
Access level: 2
VECTOR, VECTOR_AC
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8011
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
90.00 [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1255
SINAMICS parameters
3.2 SINAMICS parameters
p2163[0...n]
Velocity threshold value 4 / v_thr val 4
SERVO (Lin),
Can be changed: T, U
Calculated:
Access level: 2
SERVO_AC (Lin)
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8011
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
0.90 [m/min]
p2164[0...n]
Hysteresis velocity 4 / v_hysteresis 4
HLA
Can be changed: T, U
Calculated:
Access level: 2
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
10.00 [m/min]
0.02 [m/min]
p2164[0...n]
Hysteresis speed 4 / n_hysteresis 4
SERVO, SERVO_AC,
Can be changed: T, U
Calculated:
Access level: 2
VECTOR, VECTOR_AC
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8011
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
200.00 [rpm]
2.00 [rpm]
p2164[0...n]
Hysteresis velocity 4 / v_hysteresis 4
SERVO (Lin),
Can be changed: T, U
Calculated:
Access level: 2
SERVO_AC (Lin)
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8011
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
10.00 [m/min]
0.02 [m/min]
p2165[0...n]
Load monitoring stall monitoring upper threshold / Stall_mon up thr
SERVO (Ext msg, Lin),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Ext msg,
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 8013
Lin)
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
0.00 [m/min]
Machine data and parameters
1256
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2165[0...n]
Load monitoring stall monitoring upper threshold / Stall_mon up thr
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Ext msg),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
0.00 [rpm]
p2166[0...n]
Off-delay v_act = v_set / t_del_off n_i=n_so
HLA
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
10000.0 [ms]
200.0 [ms]
p2166[0...n]
Off-delay n_act = n_set / t_del_off n_i=n_so
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8011
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
10000.0 [ms]
200.0 [ms]
p2166[0...n]
Off-delay v_act = v_set / t_del_off n_i=n_so
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8011
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
10000.0 [ms]
200.0 [ms]
p2167[0...n]
Switch-on delay n_act = n_set / t_on n_act=n_set
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8011
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
10000.0 [ms]
200.0 [ms]
p2167[0...n]
On-delay v_act = v_set / t_on n_act=n_set
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8011
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
10000.0 [ms]
200.0 [ms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1257
SINAMICS parameters
3.2 SINAMICS parameters
p2168[0...n]
Load monitoring stall monitoring torque threshold / Stall_mon M_thr
SERVO (Ext msg, Lin),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Ext msg,
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 8013
Lin)
P-Group: Messages
Unit group: 8_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [N]
100000.00 [N]
100000.00 [N]
p2168[0...n]
Load monitoring stall monitoring torque threshold / Stall_mon M_thr
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Ext msg),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: 7_1
Unit selection: p0505
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
20000000.00 [Nm]
10000000.00 [Nm]
r2169
CO: Actual velocity smoothed signals / v_act smth message
HLA
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r2169
CO: Actual speed smoothed signals / n_act smth message
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8010
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r2169
CO: Actual velocity smoothed signals / v_act smth message
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8010
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
p2174[0...n]
Torque threshold value 1 / M_thr val 1
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: 7_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
20000000.00 [Nm]
5.13 [Nm]
Machine data and parameters
1258
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2174[0...n]
Force threshold value 1 / F_thr val 1
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: 8_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [N]
20000000.00 [N]
1000.00 [N]
p2174[0...n]
Torque threshold value 1 / M_thr val 1
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: 7_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
20000000.00 [Nm]
5.13 [Nm]
p2175[0...n]
Motor blocked velocity threshold / Mot blk v_thr
HLA
Can be changed: T, U
Calculated:
Access level: 3
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
1.20 [m/min]
p2175[0...n]
Motor blocked speed threshold / Mot blk n_thr
SERVO, SERVO_AC
Can be changed: T, U
Calculated:
Access level: 3
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
120.00 [rpm]
p2175[0...n]
Motor blocked velocity threshold / Mot blk v_thr
SERVO (Lin),
Can be changed: T, U
Calculated:
Access level: 3
SERVO_AC (Lin)
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
1.20 [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1259
SINAMICS parameters
3.2 SINAMICS parameters
p2175[0...n]
Motor blocked speed threshold / Mot blk n_thr
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated:
Access level: 3
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
120.00 [rpm]
p2177[0...n]
Motor blocked delay time / Mot blk t_del
HLA
Can be changed: T, U
Calculated:
Access level: 2
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
65.000 [s]
1.000 [s]
p2177[0...n]
Motor blocked delay time / Mot blk t_del
SERVO, SERVO_AC
Can be changed: T, U
Calculated:
Access level: 2
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
65.000 [s]
1.000 [s]
p2177[0...n]
Motor blocked delay time / Mot blk t_del
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated:
Access level: 2
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
65.000 [s]
1.000 [s]
p2178[0...n]
Motor stalled delay time / Mot stall t_del
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 8
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.000 [s]
10.000 [s]
0.010 [s]
Machine data and parameters
1260
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2178[0...n]
Motor stalled delay time / Mot stall t_del
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
10.000 [s]
0.010 [s]
p2181[0...n]
Load monitoring response / Load mon resp
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg),
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: -
Unit selection: -
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
0
p2182[0...n]
Load monitoring velocity threshold 1 / v_thr 1
SERVO (Ext msg, Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
Lin)
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
0.05 [m/min]
p2182[0...n]
Load monitoring speed threshold value 1 / n_thr 1
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
150.00 [rpm]
p2183[0...n]
Load monitoring velocity threshold 2 / v_thr 2
SERVO (Ext msg, Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
Lin)
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
0.05 [m/min]
p2183[0...n]
Load monitoring speed threshold value 2 / n_thr 2
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
900.00 [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1261
SINAMICS parameters
3.2 SINAMICS parameters
p2184[0...n]
Load monitoring velocity threshold 3 / v_thr 3
SERVO (Ext msg, Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
Lin)
P-Group: Messages
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
0.05 [m/min]
p2184[0...n]
Load monitoring speed threshold value 3 / n_thr 3
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: 3_1
Unit selection: p0505
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
1500.00 [rpm]
p2185[0...n]
Load monitoring force threshold 1 upper / F_thr 1 upper
SERVO (Ext msg, Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
Lin)
P-Group: Messages
Unit group: 8_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [N]
100000.00 [N]
100000.00 [N]
p2185[0...n]
Load monitoring torque threshold 1 upper / M_thr 1 upper
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: 7_1
Unit selection: p0505
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
20000000.00 [Nm]
10000000.00 [Nm]
p2186[0...n]
Load monitoring force threshold 1 lower / F_thr 1 lower
SERVO (Ext msg, Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
Lin)
P-Group: Messages
Unit group: 8_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [N]
100000.00 [N]
0.00 [N]
p2186[0...n]
Load monitoring torque threshold 1 lower / M_thr 1 lower
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: 7_1
Unit selection: p0505
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
20000000.00 [Nm]
0.00 [Nm]
Machine data and parameters
1262
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2187[0...n]
Load monitoring force threshold 2 upper / F_thr 2 upper
SERVO (Ext msg, Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
Lin)
P-Group: Messages
Unit group: 8_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [N]
100000.00 [N]
100000.00 [N]
p2187[0...n]
Load monitoring torque threshold 2 upper / M_thr 2 upper
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: 7_1
Unit selection: p0505
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
20000000.00 [Nm]
10000000.00 [Nm]
p2188[0...n]
Load monitoring force threshold 2 lower / F_thr 2 lower
SERVO (Ext msg, Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
Lin)
P-Group: Messages
Unit group: 8_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [N]
100000.00 [N]
0.00 [N]
p2188[0...n]
Load monitoring torque threshold 2 lower / M_thr 2 lower
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: 7_1
Unit selection: p0505
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
20000000.00 [Nm]
0.00 [Nm]
p2189[0...n]
Load monitoring force threshold 3 upper / F_thr 3 upper
SERVO (Ext msg, Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
Lin)
P-Group: Messages
Unit group: 8_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [N]
100000.00 [N]
100000.00 [N]
p2189[0...n]
Load monitoring torque threshold 3 upper / M_thr 3 upper
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: 7_1
Unit selection: p0505
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
20000000.00 [Nm]
10000000.00 [Nm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1263
SINAMICS parameters
3.2 SINAMICS parameters
p2190[0...n]
Load monitoring force threshold 3 lower / F_thr 3 lower
SERVO (Ext msg, Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
Lin)
P-Group: Messages
Unit group: 8_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [N]
100000.00 [N]
0.00 [N]
p2190[0...n]
Load monitoring torque threshold 3 lower / M_thr 3 lower
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: 7_1
Unit selection: p0505
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
20000000.00 [Nm]
0.00 [Nm]
p2191[0...n]
Load monitoring torque threshold no load / M_thr no load
SERVO (Ext msg, Lin),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Ext msg,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
Lin)
P-Group: Messages
Unit group: 8_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [N]
100000.00 [N]
0.00 [N]
p2191[0...n]
Load monitoring torque threshold no load / M_thr no load
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Ext msg),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: 7_1
Unit selection: p0505
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
20000000.00 [Nm]
0.00 [Nm]
p2192[0...n]
Load monitoring delay time / Load mon t_del
SERVO (Ext msg),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext msg),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
VECTOR (Ext msg),
P-Group: Messages
Unit group: -
Unit selection: -
VECTOR_AC (Ext msg)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [s]
65.00 [s]
10.00 [s]
p2194[0...n]
Torque threshold value 2 / M_thr val 2
SERVO, SERVO_AC,
Can be changed: T, U
Calculated:
Access level: 2
VECTOR, VECTOR_AC
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
100.00 [%]
90.00 [%]
Machine data and parameters
1264
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2194[0...n]
Force threshold value 2 / F_thr val 2
SERVO (Lin),
Can be changed: T, U
Calculated:
Access level: 2
SERVO_AC (Lin)
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
100.00 [%]
90.00 [%]
p2195[0...n]
Torque utilization switch-off delay / M_util t_off
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
1000.0 [ms]
800.0 [ms]
p2195[0...n]
Force utilization switch-off delay / F_util t_off
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8012
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
1000.0 [ms]
800.0 [ms]
p2196[0...n]
Torque utilization scaling / M_util scal
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
1000.00 [%]
100.00 [%]
r2197.1...13
CO/BO: Status word monitoring 1 / ZSW mon 1
HLA
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2197.1...13
CO/BO: Status word monitoring 1 / ZSW mon 1
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: 2534
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1265
SINAMICS parameters
3.2 SINAMICS parameters
r2197.1...13
CO/BO: Status word monitoring 1 / ZSW mon 1
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: -
Function diagram: 2534
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2198.4...12
CO/BO: Status word monitoring 2 / ZSW monitor 2
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 2536
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2198.4...12
CO/BO: Status word monitoring 2 / ZSW monitor 2
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: -
Function diagram: 2536
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2198.4...12
CO/BO: Status word monitoring 2 / ZSW monitor 2
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 2536
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2199.0...11
CO/BO: Status word monitoring 3 / ZSW monitor 3
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 2537
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2199.0...11
CO/BO: Status word monitoring 3 / ZSW monitor 3
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: -
Function diagram: 2537
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1266
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2199.0...14
CO/BO: Status word monitoring 3 / ZSW monitor 3
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 2537
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2200[0...n]
BI: Technology controller enable / Tec_ctrl enable
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2201[0...n]
CO: Technology controller fixed value 1 / Tec_ctrl FixVal 1
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950, 7951
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
10.00 [%]
p2202[0...n]
CO: Technology controller fixed value 2 / Tec_ctrl FixVal 2
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950, 7951
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
20.00 [%]
p2203[0...n]
CO: Technology controller fixed value 3 / Tec_ctrl FixVal 3
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950, 7951
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
30.00 [%]
p2204[0...n]
CO: Technology controller fixed value 4 / Tec_ctrl FixVal 4
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950, 7951
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
40.00 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1267
SINAMICS parameters
3.2 SINAMICS parameters
p2205[0...n]
CO: Technology controller fixed value 5 / Tec_ctrl FixVal 5
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
50.00 [%]
p2206[0...n]
CO: Technology controller fixed value 6 / Tec_ctrl FixVal 6
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
60.00 [%]
p2207[0...n]
CO: Technology controller fixed value 7 / Tec_ctrl FixVal 7
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
70.00 [%]
p2208[0...n]
CO: Technology controller fixed value 8 / Tec_ctrl FixVal 8
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
80.00 [%]
p2209[0...n]
CO: Technology controller fixed value 9 / Tec_ctrl FixVal 9
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
90.00 [%]
p2210[0...n]
CO: Technology controller fixed value 10 / Tec_ctrl FixVal 10
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
100.00 [%]
Machine data and parameters
1268
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2211[0...n]
CO: Technology controller fixed value 11 / Tec_ctrl FixVal 11
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
110.00 [%]
p2212[0...n]
CO: Technology controller fixed value 12 / Tec_ctrl FixVal 12
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
120.00 [%]
p2213[0...n]
CO: Technology controller fixed value 13 / Tec_ctrl FixVal 13
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
130.00 [%]
p2214[0...n]
CO: Technology controller fixed value 14 / Tec_ctrl FixVal 14
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
140.00 [%]
p2215[0...n]
CO: Technology controller fixed value 15 / Tec_ctrl FixVal 15
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
150.00 [%]
p2216[0...n]
Technology controller fixed value selection method / Tec_ctr FixVal sel
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: 7950, 7951
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
2
2
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1269
SINAMICS parameters
3.2 SINAMICS parameters
p2220[0...n]
BI: Technology controller fixed value selection bit 0 / Tec_ctrl sel bit 0
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 7950, 7951
VECTOR (Tech_ctrl),
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2221[0...n]
BI: Technology controller fixed value selection bit 1 / Tec_ctrl sel bit 1
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 7950, 7951
VECTOR (Tech_ctrl),
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2222[0...n]
BI: Technology controller fixed value selection bit 2 / Tec_ctrl sel bit 2
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 7950, 7951
VECTOR (Tech_ctrl),
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2223[0...n]
BI: Technology controller fixed value selection bit 3 / Tec_ctrl sel bit 3
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 7950, 7951
VECTOR (Tech_ctrl),
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r2224
CO: Technology controller fixed value effective / Tec_ctr FixVal eff
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7950, 7951
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r2225.0
CO/BO: Technology controller fixed value selection status word / Tec_ctr FixVal ZSW
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Unsigned16
Dynamic index: -
Function diagram: -
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1270
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2229
Technology controller number actual / Tec_ctrl no act
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: Unsigned32
Dynamic index: -
Function diagram: 7950
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2230[0...n]
Technology controller motorized potentiometer configuration / Tec_ctr moP config
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Unsigned32
Dynamic index: DDS, p0180 Function diagram: 7954
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0100 bin
r2231
Technology controller motorized potentiometer setpoint memory / Tec_ctrl moP mem
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7954
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p2235[0...n]
BI: Technology controller motorized potentiometer raise setpoint / Tec_ctrl moP raise
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 7954
VECTOR (Tech_ctrl),
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2236[0...n]
BI: Technology controller motorized potentiometer lower setpoint / Tec_ctrl moP lower
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 7954
VECTOR (Tech_ctrl),
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2237[0...n]
Technology controller motorized potentiometer maximum value / Tec_ctrl moP max
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 7954
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
100.00 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1271
SINAMICS parameters
3.2 SINAMICS parameters
p2238[0...n]
Technology controller motorized potentiometer minimum value / Tec_ctrl moP min
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 7954
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
-100.00 [%]
p2240[0...n]
Technology controller motorized potentiometer starting value / Tec_ctrl moP start
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 7954
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
0.00 [%]
r2245
CO: Technology controller mot. potentiometer setpoint before RFG / Tec_ctr mop befRFG
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7954
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p2247[0...n]
Technology controller motorized potentiometer ramp-up time / Tec_ctr moP t_r-up
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 7954
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [s]
1000.0 [s]
10.0 [s]
p2248[0...n]
Technology controller motorized potentiometer ramp-down time / Tec_ctrMoP t_rdown
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 7954
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [s]
1000.0 [s]
10.0 [s]
r2250
CO: Technology controller motorized potentiometer setpoint after RFG / Tec_ctr moP
aftRFG
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7954
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
Machine data and parameters
1272
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2251
Technology controller mode / Tec_ctrl mode
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl)
Data type: Integer16
Dynamic index: -
Function diagram: 7958
P-Group: Technology
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
2
2
2
p2252
Technology controller configuration / Tec_ctrl config
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Unsigned16
Dynamic index: -
Function diagram: -
VECTOR (Tech_ctrl),
P-Group: Modulation
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0111 bin
p2253[0...n]
CI: Technology controller setpoint 1 / Tec_ctrl set 1
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2254[0...n]
CI: Technology controller setpoint 2 / Tec_ctrl set 2
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2255
Technology controller setpoint 1 scaling / Tec_ctrl set1 scal
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
100.00 [%]
100.00 [%]
p2256
Technology controller setpoint 2 scaling / Tec_ctrl set2 scal
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
100.00 [%]
100.00 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1273
SINAMICS parameters
3.2 SINAMICS parameters
p2257
Technology controller ramp-up time / Tec_ctrl t_ramp-up
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [s]
650.00 [s]
1.00 [s]
p2258
Technology controller ramp-down time / Tec_ctrl t_ramp-dn
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [s]
650.00 [s]
1.00 [s]
r2260
CO: Technology controller setpoint after ramp-function generator / Tec_ctr set aftRFG
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p2261
Technology controller setpoint filter time constant / Tec_ctrl set Tc
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
60.000 [s]
0.000 [s]
r2262
CO: Technology controller setpoint after filter / Tec_ctr set aftFil
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p2263
Technology controller type / Tec_ctrl type
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Integer16
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
1274
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2264[0...n]
CI: Technology controller actual value / Tec_ctrl ActV
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2265
Technology controller actual value filter time constant / Tec_ctrl act Tc
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
60.000 [s]
0.000 [s]
r2266
CO: Technology controller actual value after filter / Tec_ctr act aftFil
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p2267
Technology controller upper limit actual value / Tec_ctrl u_lim act
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-10000.00 [%]
10000.00 [%]
200.00 [%]
p2268
Technology controller lower limit actual value / Tec_ctrl l_lim act
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-10000.00 [%]
10000.00 [%]
-200.00 [%]
p2269
Technology controller gain actual value / Tec_ctrl gain ActV
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
500.00 [%]
100.00 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1275
SINAMICS parameters
3.2 SINAMICS parameters
p2270
Technology controller actual value function / Tec_ctr ActV fct
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Integer16
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
p2271
Technology controller actual value inversion (sensor type) / Tec_ctrl ActV inv
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Integer16
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
r2272
CO: Technology controller actual value scaled / Tec_ctrl ActV scal
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r2273
CO: Technology controller system deviation / Tec_ctrl SysDev
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p2274
Technology controller differentiation time constant / Tec_ctrl D comp Tc
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
60.000 [s]
0.000 [s]
p2280
Technology controller proportional gain / Tec_ctrl Kp
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
1000.000
1.000
Machine data and parameters
1276
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2285
Technology controller integral time / Tec_ctrl Tn
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
60.000 [s]
0.000 [s]
p2286[0...n]
BI: Hold technology controller integrator / Tec_ctr integ hold
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2289[0...n]
CI: Technology controller precontrol signal / Tec_ctr prectr_sig
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2291
CO: Technology controller maximum limiting / Tec_ctrl max_lim
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
100.00 [%]
p2292
CO: Technology controller minimum limiting / Tec_ctrl min_lim
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-200.00 [%]
200.00 [%]
0.00 [%]
p2293
Technology controller ramp-up/ramp-down time / Tec_ctr t_RU/RD
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [s]
100.00 [s]
1.00 [s]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1277
SINAMICS parameters
3.2 SINAMICS parameters
r2294
CO: Technology controller output signal / Tec_ctrl outp_sig
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p2295
CO: Technology controller output scaling / Tec_ctrl outp scal
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-100.00 [%]
100.00 [%]
100.00 [%]
p2296[0...n]
CI: Technology controller output scaling / Tec_ctrl outp scal
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
2295[0]
p2297[0...n]
CI: Technology controller maximum limit signal source / Tec_ctrl max_l s_s
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
2291[0]
p2298[0...n]
CI: Technology controller minimum limit signal source / Tec_ctrl min_l s_s
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
2292[0]
p2299[0...n]
CI: Technology controller limit offset / Tec_ctrl lim offs
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1278
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2306
Technology controller system deviation inversion / Tec_ctr SysDev inv
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Integer16
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p2310
CI: Technology controller Kp adaptation input value signal source / Kp adpt inp s_s
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7959
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2311
Technology controller Kp adaptation lower value / Kp adpt lower val
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7959
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
1000.000
1.000
p2312
Technology controller Kp adaptation upper value / Kp adpt upper val
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7959
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
1000.000
10.000
p2313
Technology controller Kp adaptation lower starting point / Kp adpt lower pt
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7959
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
400.00 [%]
0.00 [%]
p2314
Technology controller Kp adaptation upper starting point / Kp adpt upper pt
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7959
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
400.00 [%]
100.00 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1279
SINAMICS parameters
3.2 SINAMICS parameters
p2315
CI: Technology controller Kp adaptation scaling signal source / Kp adpt scal s_s
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7959
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
r2316
CO: Technology controller, Kp adaptation output / Kp adpt outp
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7959
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2317
CI: Technology controller Tn adaptation input value signal source / Tn adpt inp s_s
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7959
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2318
Technology controller Tn adaptation upper value / Tn adpt upper val
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7959
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
60.000 [s]
3.000 [s]
p2319
Technology controller Tn adaptation lower value / Tn adpt lower val
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7959
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
60.000 [s]
10.000 [s]
p2320
Technology controller Tn adaptation lower starting point / Tn adpt lower pt
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7959
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
400.00 [%]
0.00 [%]
Machine data and parameters
1280
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2321
Technology controller Tn adaptation upper starting point / Tn adpt upper pt
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7959
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
400.00 [%]
100.00 [%]
r2322
CO: Technology controller Tn adaptation output / Tn adapt outp
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7959
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [s]
- [s]
- [s]
r2323
CO: Technology controller adaptive Tn scaled output / TecCtr ad Tn ScOut
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [s]
- [s]
- [s]
p2339
Hold techn. controller I component for n_skip threshold value / Hold I comp thr
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: 9_1
Unit selection: p0595
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
200.00 [%]
2.00 [%]
r2349.0...13
CO/BO: Technology controller status word / Tec_ctrl ZSW
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Tech_ctrl),
Data type: Unsigned32
Dynamic index: -
Function diagram: 7958
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2369
BI: Closed-loop cascade control, control word / Csc_ctrl STW
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1281
SINAMICS parameters
3.2 SINAMICS parameters
p2369
BI: Closed-loop cascade control, control word / Csc_ctrl STW
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (Tech_ctrl)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2398
Hibernation mode operating type / Hib mode op_type
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl),
Data type: Integer16
Dynamic index: -
Function diagram: 7038
VECTOR (Tech_ctrl),
P-Group: Technology
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p2502[0...n]
LR encoder assignment / Encoder assignment
SERVO (Pos ctrl),
Can be changed: C2(25)
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
1
p2503[0...n]
LR length unit LU per 10 mm / LU per 10 mm
SERVO (APC, APC, AVS/
Can be changed: C2(25)
Calculated: -
Access level: 1
APC-ECO, AVS/APC-
Data type: Unsigned32
Dynamic index: DDS, p0180
Function diagram: 4010
ECO, Pos ctrl, Pos ctrl,
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
Pos ctrl), SERVO_AC
(APC, APC, AVS/APC-
Not for motor type: -
Scaling: -
Expert list: 1
ECO, AVS/APC-ECO, Pos
Min:
Max:
Factory setting:
ctrl, Pos ctrl, Pos ctrl),
1 [LU]
2147483647 [LU]
10000 [LU]
VECTOR (Pos ctrl),
VECTOR_AC (Pos ctrl)
p2504[0...n]
LR motor/load motor distance / Mot/load mot dis
SERVO (APC, APC, AVS/
Can be changed: C2(25)
Calculated: -
Access level: 1
APC-ECO, AVS/APC-
Data type: Unsigned32
Dynamic index: DDS, p0180
Function diagram: 4010, 4704,
ECO, Lin, Lin, Lin, Lin,
4711
Lin, Pos ctrl, Pos ctrl,
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
Pos ctrl), SERVO_AC
(APC, APC, AVS/APC-
Not for motor type: -
Scaling: -
Expert list: 1
ECO, AVS/APC-ECO,
Min:
Max:
Factory setting:
Lin, Lin, Lin, Lin, Lin,
1
1048576
1
Pos ctrl, Pos ctrl, Pos
ctrl)
Machine data and parameters
1282
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2504[0...n]
LR motor/load motor revolutions / Mot/load mot rev
SERVO (APC, APC, AVS/
Can be changed: C2(25)
Calculated: -
Access level: 1
APC-ECO, AVS/APC-
Data type: Unsigned32
Dynamic index: DDS, p0180
Function diagram: 4010, 4704,
ECO, Pos ctrl, Pos ctrl,
4711
Pos ctrl), SERVO_AC
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
(APC, APC, AVS/APC-
ECO, AVS/APC-ECO, Pos
Not for motor type: -
Scaling: -
Expert list: 1
ctrl, Pos ctrl, Pos ctrl),
Min:
Max:
Factory setting:
VECTOR (Pos ctrl),
1
1048576
1
VECTOR_AC (Pos ctrl)
p2505[0...n]
LR motor/load load revolutions / Mot/load load rev
SERVO (APC, APC, AVS/
Can be changed: C2(25)
Calculated: -
Access level: 1
APC-ECO, AVS/APC-
Data type: Integer32
Dynamic index: DDS, p0180
Function diagram: 4010, 4704,
ECO, Pos ctrl, Pos ctrl,
4711
Pos ctrl), SERVO_AC
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
(APC, APC, AVS/APC-
ECO, AVS/APC-ECO, Pos
Not for motor type: -
Scaling: -
Expert list: 1
ctrl, Pos ctrl, Pos ctrl),
Min:
Max:
Factory setting:
VECTOR (Pos ctrl),
-1048576
1048576
1
VECTOR_AC (Pos ctrl)
p2506[0...n]
LR length unit LU per load path / LU per load path
SERVO (APC, APC, AVS/
Can be changed: C2(25)
Calculated: -
Access level: 1
APC-ECO, AVS/APC-
Data type: Unsigned32
Dynamic index: DDS, p0180
Function diagram: 4010
ECO, Lin, Lin, Lin, Lin,
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
Lin, Pos ctrl, Pos ctrl,
Pos ctrl), SERVO_AC
Not for motor type: -
Scaling: -
Expert list: 1
(APC, APC, AVS/APC-
Min:
Max:
Factory setting:
ECO, AVS/APC-ECO,
1 [LU]
2147483647 [LU]
10000 [LU]
Lin, Lin, Lin, Lin, Lin,
Pos ctrl, Pos ctrl, Pos
ctrl)
p2506[0...n]
LR length unit LU per load revolution / LU per load rev
SERVO (APC, APC, AVS/
Can be changed: C2(25)
Calculated: -
Access level: 1
APC-ECO, AVS/APC-
Data type: Unsigned32
Dynamic index: DDS, p0180
Function diagram: 4010
ECO, Pos ctrl, Pos ctrl,
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
Pos ctrl), SERVO_AC
(APC, APC, AVS/APC-
Not for motor type: -
Scaling: -
Expert list: 1
ECO, AVS/APC-ECO, Pos
Min:
Max:
Factory setting:
ctrl, Pos ctrl, Pos ctrl),
1 [LU]
2147483647 [LU]
10000 [LU]
VECTOR (Pos ctrl),
VECTOR_AC (Pos ctrl)
p2507[0...n]
LR absolute encoder adjustment status / Abs_enc_adj stat
SERVO (EPOS, Pos ctrl,
Can be changed: T, U
Calculated: -
Access level: 1
Pos ctrl), SERVO_AC
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: 4010
(EPOS, Pos ctrl, Pos
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
ctrl), VECTOR (EPOS,
Pos ctrl, Pos ctrl),
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC (EPOS, Pos
Min:
Max:
Factory setting:
ctrl, Pos ctrl)
0
4
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1283
SINAMICS parameters
3.2 SINAMICS parameters
p2508[0...3]
BI: LR activate reference mark search / Ref_mark act
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2509[0...3]
BI: LR activate measuring probe evaluation / MT_eval act
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2510[0...3]
BI: LR selecting measuring probe evaluation / MT_eval select
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3615, 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2511[0...3]
BI: LR measuring probe evaluation edge / MT_eval edge
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3615, 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2512[0...3]
BI: LR pos. actual value preprocessing activate corr. value (edge) / ActV_prepCorrAct
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 4010, 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2513[0...3]
CI: LR Position actual value preprocessing corrective value / ActV_prep corr
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 4010, 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1284
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2514[0...3]
BI: LR activate position actual value setting / s_act setting act
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2515[0...3]
CI: LR position actual setting setting value / s_act set setVal
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2516[0...3]
CI: LR position offset / Position offset
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2517[0...2]
LR direct measuring probe 1 / Direct MT 1
SERVO (Dig IO, Pos ctrl) Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 4010
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
51
0
p2517[0...2]
LR direct measuring probe 1 / Direct MT 1
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Pos ctrl),
Data type: Integer16
Dynamic index: -
Function diagram: 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
18
0
p2518[0...2]
LR direct measuring probe 2 / Direct MT 2
SERVO (Dig IO, Pos ctrl) Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 4010
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
51
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1285
SINAMICS parameters
3.2 SINAMICS parameters
p2518[0...2]
LR direct measuring probe 2 / Direct MT 2
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Pos ctrl),
Data type: Integer16
Dynamic index: -
Function diagram: 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
18
0
p2519[0...n]
LR position actual value preprocessing config. DDS changeover / s_act config DDS
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
SERVO_AC (Pos ctrl),
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: -
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
5
1
r2520[0...2]
CO: LR Position actual value preprocessing encoder control word / ActV_prep STW
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned16
Dynamic index: -
Function diagram: 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2521[0...3]
CO: LR position actual value / s_act
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Integer32
Dynamic index: -
Function diagram: 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
r2522[0...3]
CO: LR velocity actual value / v_act
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Integer32
Dynamic index: -
Function diagram: 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [1000 LU/min]
- [1000 LU/min]
- [1000 LU/min]
r2523[0...3]
CO: LR measured value / Measured value
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Integer32
Dynamic index: -
Function diagram: 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
Machine data and parameters
1286
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2524
CO: LR LU/mm / LU/mm
SERVO (Lin, Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Lin, Pos
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3630, 4010
ctrl)
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
r2524
CO: LR LU/revolution / LU/revolution
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3630, 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
p2525[0...n]
CO: LR encoder adjustment offset / Enc_adj offset
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 4
SERVO_AC (Pos ctrl),
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: 4010
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [LU]
4294967295 [LU]
0 [LU]
r2526.0...9
CO/BO: LR status word / ZSW
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned16
Dynamic index: -
Function diagram: -
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2527.0...2
CO/BO: LR actual value sensing status word encoder 1 / ActV SensZSW enc 1
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned16
Dynamic index: -
Function diagram: -
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2528.0...2
CO/BO: LR actual value sensing status word encoder 2 / ActV SensZSW enc 2
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned16
Dynamic index: -
Function diagram: -
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1287
SINAMICS parameters
3.2 SINAMICS parameters
r2529.0...2
CO/BO: LR actual value sensing status word encoder 3 / ActV SensZSW enc 3
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned16
Dynamic index: -
Function diagram: -
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2530
CI: LR position setpoint / s_set
SERVO (EPOS, Pos ctrl,
Can be changed: T
Calculated: -
Access level: 1
Pos ctrl), SERVO_AC
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 4015, 4020
(EPOS, Pos ctrl, Pos
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
ctrl), VECTOR (EPOS,
Pos ctrl, Pos ctrl),
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC (EPOS, Pos
Min:
Max:
Factory setting:
ctrl, Pos ctrl)
-
-
0
p2531
CI: LR velocity setpoint / v_set
SERVO (EPOS, Pos ctrl,
Can be changed: T
Calculated: -
Access level: 1
Pos ctrl), SERVO_AC
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 4015
(EPOS, Pos ctrl, Pos
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
ctrl), VECTOR (EPOS,
Pos ctrl, Pos ctrl),
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC (EPOS, Pos
Min:
Max:
Factory setting:
ctrl, Pos ctrl)
-
-
0
p2532
CI: LR position actual value / s_act
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 4015, 4020,
VECTOR (Pos ctrl),
4025
VECTOR_AC (Pos ctrl)
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2521[0]
p2533[0...n]
LR position setpoint filter time constant / s_set_filt Tc
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
1000.00 [ms]
0.00 [ms]
p2534[0...n]
LR velocity precontrol factor / v_prectrl fact
SERVO (Lin, Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Lin, Pos
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4015, 4025
ctrl)
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
200.00 [%]
0.00 [%]
Machine data and parameters
1288
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2534[0...n]
LR speed precontrol factor / n_prectrl fact
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4015, 4025
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
200.00 [%]
0.00 [%]
p2535[0...n]
LR velocity precontrol symmetrizing filter dead time / v_prectrFil t_dead
SERVO (Lin, Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Lin, Pos
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4015
ctrl)
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
2.00
0.00
p2535[0...n]
LR speed precontrol symmetrizing filter dead time / n_prectrFil t_dead
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
2.00
0.00
p2536[0...n]
LR velocity precontrol symmetrizing filter PT1 / v_prectrl filt PT1
SERVO (Lin, Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Lin, Pos
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4015
ctrl)
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
100.00 [ms]
0.00 [ms]
p2536[0...n]
LR speed precontrol symmetrizing filter PT1 / n_prectrl filt PT1
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
100.00 [ms]
0.00 [ms]
p2537
CI: LR position controller adaptation / Adaptation
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1289
SINAMICS parameters
3.2 SINAMICS parameters
p2538[0...n]
LR proportional gain / Kp
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [1000 rpm]
300.000 [1000 rpm]
1.000 [1000 rpm]
p2539[0...n]
LR integral time / Tn
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
100000.00 [ms]
0.00 [ms]
p2540
CO: LR position controller output velocity limit / LR_outp v_lim
SERVO (Lin, Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin, Pos
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
ctrl)
P-Group: Closed-loop position control
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [m/min]
1000.000 [m/min]
1000.000 [m/min]
p2540
CO: LR position controller output speed limit / LR_outp n_lim
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: 3_1
Unit selection: p0505
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [rpm]
210000.000 [rpm]
210000.000 [rpm]
p2541
CI: LR position controller output velocity limit signal source / LR_outp v_lim s_s
SERVO (Lin, Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Lin, Pos
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 4015
ctrl)
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
2540[0]
p2541
CI: LR position controller output speed limit signal source / LR_outp n_lim s_s
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
2540[0]
Machine data and parameters
1290
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2542
LR standstill window / Standstill window
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32
Dynamic index: -
Function diagram: 4020
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [LU]
2147483647 [LU]
200 [LU]
p2543
LR standstill monitoring time / t_standstill mon
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4020
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
100000.00 [ms]
200.00 [ms]
p2544
LR positioning window / Pos_window
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32
Dynamic index: -
Function diagram: 4020
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [LU]
2147483647 [LU]
40 [LU]
p2545
LR positioning monitoring time / t_pos_mon
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4020
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
100000.00 [ms]
1000.00 [ms]
p2546[0...n]
LR dynamic following error monitoring tolerance / s_delta_mon tol
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32
Dynamic index: DDS, p0180 Function diagram: 4025
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [LU]
2147483647 [LU]
1000 [LU]
p2547
LR cam switching position 1 / Cam position 1
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Integer32
Dynamic index: -
Function diagram: 4025
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-2147483648 [LU]
2147483647 [LU]
0 [LU]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1291
SINAMICS parameters
3.2 SINAMICS parameters
p2548
LR cam switching position 2 / Cam position 2
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Integer32
Dynamic index: -
Function diagram: 4025
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-2147483648 [LU]
2147483647 [LU]
0 [LU]
p2549
BI: LR enable 1 / Enable 1
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
899.2
p2550[0...n]
BI: LR enable 2 / Enable 2
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2551
BI: LR setpoint signal fixed / Mess set fixed
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 4020
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2552
BI: LR signal travel to fixed stop active / Signal TfS act
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 4025
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2553
BI: LR signal fixed stop reached / Signal fixed stop
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 4025
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1292
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2554
BI: LR signal traversing command active / Sig trav_cmnd act
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 4020
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2555
CI: LR LU/revolution LU/mm / LU/rev LU/mm
SERVO (Pos ctrl),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Pos ctrl),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2524[0]
r2556
CO: LR position setpoint after setpoint smoothing / s_set after interp
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Integer32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
r2557
CO: LR position controller input system deviation / LR_inp SysDev
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Integer32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
r2558
CO: LR position controller output P component / LR_outp P comp
SERVO (Lin, Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Lin, Pos
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
ctrl)
P-Group: Closed-loop position control
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r2558
CO: LR position controller output P component / LR_outp P comp
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: 3_1
Unit selection: p0505
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1293
SINAMICS parameters
3.2 SINAMICS parameters
r2559
CO: LR position controller output I component / LR_outp I comp
SERVO (Lin, Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Lin, Pos
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
ctrl)
P-Group: Closed-loop position control
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r2559
CO: LR position controller output I component / LR_outp I comp
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: 3_1
Unit selection: p0505
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r2560
CO: LR velocity setpoint / v_set
SERVO (Lin, Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Lin, Pos
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
ctrl)
P-Group: Closed-loop position control
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r2560
CO: LR speed setpoint / n_set
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: 3_1
Unit selection: p0505
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r2561
CO: LR velocity precontrol value / v_prectrl val
SERVO (Lin, Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Lin, Pos
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
ctrl)
P-Group: Closed-loop position control
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r2561
CO: LR speed precontrol value / n_prectrl val
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: 3_1
Unit selection: p0505
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
Machine data and parameters
1294
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2562
CO: LR velocity setpoint total / v_set total
SERVO (Lin, Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Lin, Pos
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
ctrl)
P-Group: Closed-loop position control
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r2562
CO: LR total speed setpoint / n_set total
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: 3_1
Unit selection: p0505
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r2563
CO: LR following error dynamic model / Follow error dyn
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Integer32
Dynamic index: -
Function diagram: 4025
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
r2564
CO: LR force precontrol value / F_prectrl val
SERVO (Lin, Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Lin, Pos
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
ctrl)
P-Group: Closed-loop position control
Unit group: 8_1
Unit selection: p0505
Not for motor type: -
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [N]
- [N]
- [N]
r2564
CO: LR torque precontrol value / M_prectrl val
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: 7_1
Unit selection: p0505
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [Nm]
- [Nm]
- [Nm]
r2565
CO: LR following error actual / Following err act
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Integer32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1295
SINAMICS parameters
3.2 SINAMICS parameters
r2566
LR velocity input precontrol / v inp prectrl
SERVO (Lin, Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Lin, Pos
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
ctrl)
P-Group: Closed-loop position control
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r2566
LR speed input precontrol / n inp prectrl
SERVO (Pos ctrl),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: 3_1
Unit selection: p0505
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p2567[0...n]
LR force precontrol mass / F_prectrl mass
SERVO (Lin, Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin, Pos
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4015
ctrl)
P-Group: Closed-loop position control
Unit group: 27_1
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000000 [kg]
100000.000000 [kg]
1.000000 [kg]
p2567[0...n]
LR torque precontrol moment of inertia / M_prectrl M_inert
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Pos ctrl),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4015
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: 25_1
Unit selection: p0100
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000000 [kgm²]
100000.000000 [kgm²]
0.159155 [kgm²]
p2568
BI: EPOS STOP cam activation / STOP cam act
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2569
BI: EPOS STOP cam minus / STOP cam minus
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
1296
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2570
BI: EPOS STOP cam plus / STOP cam plus
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p2571
EPOS maximum velocity / v_max
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [1000 LU/min]
40000000 [1000 LU/min]
30000 [1000 LU/min]
p2572
EPOS maximum acceleration / a_max
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [1000 LU/s²]
2000000 [1000 LU/s²]
100 [1000 LU/s²]
p2573
EPOS maximum deceleration / -a_max
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [1000 LU/s²]
2000000 [1000 LU/s²]
100 [1000 LU/s²]
p2574
EPOS jerk limiting / Jerk lim
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3635
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [1000 LU/s³]
100000000 [1000 LU/s³]
10000 [1000 LU/s³]
p2575
BI: EPOS jerk limiting activation / Jerk limit act
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3635
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1297
SINAMICS parameters
3.2 SINAMICS parameters
p2576
EPOS modulo correction modulo range / Modulo corr range
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3635
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [LU]
2147482647 [LU]
360000 [LU]
p2577
BI: EPOS modulo correction activation / Modulo corr act
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3630, 3635
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2578
CI: EPOS software limit switch minus signal source / SW lim sw min s_s
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2580[0]
p2579
CI: EPOS software limit switch plus signal source / SW lim sw plus s_s
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2581[0]
p2580
CO: EPOS software limit switch minus / SW lim sw minus
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-2147482648 [LU]
2147482647 [LU]
-2147482648 [LU]
p2581
CO: EPOS software limit switch plus / SW lim sw plus
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-2147482648 [LU]
2147482647 [LU]
2147482647 [LU]
Machine data and parameters
1298
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2582
BI: EPOS software limit switch activation / SW lim sw act
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2583
EPOS backlash compensation / Backlash comp
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3635
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-200000 [LU]
200000 [LU]
0 [LU]
p2584
EPOS functions configuration / EPOS fct config
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p2585
EPOS jog 1 setpoint velocity / Jog 1 v_set
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3610
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-40000000 [1000 LU/min]
40000000 [1000 LU/min]
-300 [1000 LU/min]
p2586
EPOS jog 2 setpoint velocity / Jog 2 v_set
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3610
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-40000000 [1000 LU/min]
40000000 [1000 LU/min]
300 [1000 LU/min]
p2587
EPOS jog 1 traversing distance / Jog 1 distance
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3610
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [LU]
2147482647 [LU]
1000 [LU]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1299
SINAMICS parameters
3.2 SINAMICS parameters
p2588
EPOS jog 2 traversing distance / Jog 2 distance
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3610
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [LU]
2147482647 [LU]
1000 [LU]
p2589
BI: EPOS jog 1 signal source / Jog 1 s_s
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3610, 3625
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2590
BI: EPOS jog 2 signal source / Jog 2 s_s
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3610, 3625
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2591
BI: EPOS jogging incremental / Jog incr
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3610
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2593
CI: EPOS LU/revolution LU/mm / LU/rev LU/mm
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2524[0]
p2594[0...2]
CI: EPOS Maximum velocity externally limited / v_max ext lim
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1300
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2595
BI: EPOS referencing start / Ref start
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3612, 3625,
VECTOR (EPOS),
3614
VECTOR_AC (EPOS)
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2596
BI: EPOS set reference point / Set ref_pt
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2597
BI: EPOS referencing type selection / Ref_typ sel
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3612, 3614,
VECTOR (EPOS),
3625
VECTOR_AC (EPOS)
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2598[0...3]
CI: EPOS reference point coordinate signal source / Ref_pt coord s_s
SERVO (EPOS, Pos ctrl,
Can be changed: T
Calculated: -
Access level: 1
Pos ctrl), SERVO_AC
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 3612, 3614
(EPOS, Pos ctrl, Pos
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
ctrl), VECTOR (EPOS,
Pos ctrl, Pos ctrl),
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC (EPOS, Pos
Min:
Max:
Factory setting:
ctrl, Pos ctrl)
-
-
[0] 2599[0]
[1] 0
[2] 0
[3] 0
p2599
CO: EPOS reference point coordinate value / Ref_pt coord val
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Integer32
Dynamic index: -
Function diagram: 3612
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-2147482648 [LU]
2147482647 [LU]
0 [LU]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1301
SINAMICS parameters
3.2 SINAMICS parameters
p2600
EPOS search for reference reference point offset / Ref_pt offset
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-2147482648 [LU]
2147482647 [LU]
0 [LU]
p2601
EPOS flying referencing inner window / Inner window
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3614
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [LU]
2147482647 [LU]
0 [LU]
p2602
EPOS flying referencing outer window / Outer window
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3614
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [LU]
2147482647 [LU]
0 [LU]
p2603
EPOS flying referencing, positioning mode relative / Pos_mode relative
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3635
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
1
p2604
BI: EPOS search for reference start direction / Srch for ref dir
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2605
EPOS search for reference approach velocity reference cam / v_appr ref_cam
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [1000 LU/min]
40000000 [1000 LU/min]
5000 [1000 LU/min]
Machine data and parameters
1302
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2606
EPOS search for reference reference cam maximum distance / Ref_cam max s
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [LU]
2147482647 [LU]
2147482647 [LU]
p2607
EPOS search for reference reference cam present / Ref_cam pres
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned8
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
1
p2608
EPOS search for reference approach velocity zero mark / v_appr ref_ZM
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [1000 LU/min]
40000000 [1000 LU/min]
300 [1000 LU/min]
p2609
EPOS search for reference max distance ref cam and zero mark / Max s ref_cam ZM
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [LU]
2147482647 [LU]
20000 [LU]
p2610
EPOS search for ref. tol. bandwidth for distance to zero mark / Tol_band to ZM
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [LU]
2147482647 [LU]
2147482647 [LU]
p2611
EPOS search for reference approach velocity reference point / v_appr ref_pt
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [1000 LU/min]
40000000 [1000 LU/min]
300 [1000 LU/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1303
SINAMICS parameters
3.2 SINAMICS parameters
p2612
BI: EPOS search for reference reference cam / Ref_cam
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2613
BI: EPOS search for reference reversing cam minus / Rev minus
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p2614
BI: EPOS search for reference reversing cam plus / Rev cam plus
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p2615
EPOS maximum number of traversing blocks / Trav_block qty max
SERVO (EPOS),
Can be changed: C2(17)
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned8
Dynamic index: -
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
64
64
p2616[0...n]
EPOS traversing block block number / Trav_blk, blk no
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer16
Dynamic index: p2615
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1
63
-1
p2617[0...n]
EPOS traversing block position / Trav_block pos
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: p2615
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-2147482648 [LU]
2147482647 [LU]
0 [LU]
Machine data and parameters
1304
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2618[0...n]
EPOS traversing block velocity / Trav_block v
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: p2615
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [1000 LU/min]
40000000 [1000 LU/min]
600 [1000 LU/min]
p2619[0...n]
EPOS traversing block acceleration override / Trav_block a_over
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: FloatingPoint32
Dynamic index: p2615
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.0 [%]
100.0 [%]
100.0 [%]
p2620[0...n]
EPOS traversing deceleration override / Trav_block -a_over
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: FloatingPoint32
Dynamic index: p2615
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.0 [%]
100.0 [%]
100.0 [%]
p2621[0...n]
EPOS traversing block task / Trav_block task
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer16
Dynamic index: p2615
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
9
1
p2622[0...n]
EPOS traversing block task parameter / Trav_blck task_par
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: p2615
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-2147483648
2147483647
0
p2623[0...n]
EPOS traversing block task mode / Trav_block mode
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned16
Dynamic index: p2615
Function diagram: 3515, 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1305
SINAMICS parameters
3.2 SINAMICS parameters
p2624
EPOS traversing block sorting / Trav_block sort
SERVO (EPOS),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned16
Dynamic index: -
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p2625
BI: EPOS traversing block selection bit 0 / Trav_blk sel bit 0
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3616, 3640
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2626
BI: EPOS traversing block selection bit 1 / Trav_blk sel bit 1
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3616, 3640
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2627
BI: EPOS traversing block selection bit 2 / Trav_blk sel bit 2
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3616, 3640
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2628
BI: EPOS traversing block selection bit 3 / Trav_blk sel bit 3
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3616, 3640
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2629
BI: EPOS traversing block selection bit 4 / Trav_blk sel bit 4
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3616, 3640
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1306
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2630
BI: EPOS traversing block selection bit 5 / Trav_blk sel bit 5
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3616, 3640
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2631
BI: EPOS activate traversing task (0 -> 1) / Trav_task act
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3616, 3625
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2632
EPOS external block change evaluation / Ext blk chg eval
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer16
Dynamic index: -
Function diagram: 3615, 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p2633
BI: EPOS external block change (0 -> 1) / Ext blk chg (0->1)
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3615
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2634[0...n]
EPOS fixed stop maximum following error / Following err max
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32
Dynamic index: DDS, p0180 Function diagram: 3617, 4025
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [LU]
2147482647 [LU]
1000 [LU]
p2635
EPOS fixed stop monitoring window / Fixed stop mon
SERVO (Pos ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Pos ctrl),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3617, 4025
VECTOR (Pos ctrl),
P-Group: Closed-loop position control
Unit group: -
Unit selection: -
VECTOR_AC (Pos ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [LU]
2147482647 [LU]
100 [LU]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1307
SINAMICS parameters
3.2 SINAMICS parameters
p2637
BI: EPOS fixed stop reached / Fixed stop reached
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3616, 3617
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2526.4
p2638
BI: EPOS fixed stop outside the monitoring window / Fixed stop outside
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3616, 3617
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2526.5
p2639
BI: EPOS force limit reached / F_limit reached
SERVO (EPOS, Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (EPOS, Lin) Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3616
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1407.7
p2639
BI: EPOS torque limit reached / M_limit reached
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1407.7
p2640
BI: EPOS intermediate stop (0 signal) / Intermediate stop
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3616, 3620,
VECTOR (EPOS),
3625
VECTOR_AC (EPOS)
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2641
BI: EPOS reject traversing task (0 signal) / Trav_task reject
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3616, 3620,
VECTOR (EPOS),
3625
VECTOR_AC (EPOS)
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1308
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2642
CI: EPOS direct setpoint input/MDI position setpoint / MDI s_set
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 3618
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2690[0]
p2643
CI: EPOS direct setpoint input/MDI velocity setpoint / MDI v_set
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 3618
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2691[0]
p2644
CI: EPOS direct setpoint input/MDI acceleration override / MDI a_over
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 3618
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
2692[0]
p2645
CI: EPOS direct setpoint input/MDI deceleration override / MDI -a_over
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 3618
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
2693[0]
p2646
CI: EPOS velocity override / v_over
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p2647
BI: EPOS direct setpoint input/MDI selection / MDI selection
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3620, 3625,
VECTOR (EPOS),
3640
VECTOR_AC (EPOS)
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1309
SINAMICS parameters
3.2 SINAMICS parameters
p2648
BI: EPOS direct setpoint input/MDI positioning type / MDI pos_type
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3620
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2649
BI: EPOS direct setpoint input/MDI transfer type selection / MDI trans_type sel
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3620
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2650
BI: EPOS direct setpoint input/MDI setpoint acceptance edge / MDI set_accept
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3620
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2651
BI: EPOS direct setpoint input/MDI direction selection, positive / MDI dir_sel pos
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3620
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2652
BI: EPOS direct setpoint input/MDI direction selection negative / MDI dir_sel neg
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3620
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2653
BI: EPOS direct setpoint input/MDI setting-up selection / MDI setting-up sel
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3620
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1310
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2654
CI: EPOS direct setpoint input/MDI mode adaptation / MDI mode adapt
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 3620
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2655[0...1]
BI: EPOS select tracking mode / Sel tracking mode
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3635
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 1
[1] 2526.7
p2656
BI: EPOS enable basic positioner / EPOS enable
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3635
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2526.3
p2657
CI: EPOS position actual value/position setting value / Pos act/set value
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 3610, 3616,
VECTOR (EPOS),
3620, 3635
VECTOR_AC (EPOS)
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2521[0]
p2658
BI: EPOS position actual value valid feedback signal / Pos valid feedback
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3635
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2526.0
p2659
BI: EPOS referencing active feedback signal / Ref act fdbk
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3612
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2526.1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1311
SINAMICS parameters
3.2 SINAMICS parameters
p2660
CI: EPOS measured value referencing / Meas val ref
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 3612, 3614
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2523[0]
p2661
BI: EPOS measured value valid feedback signal / MeasVal valid fdbk
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3612, 3614,
VECTOR (EPOS),
3615
VECTOR_AC (EPOS)
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2526.2
p2662
BI: EPOS adjustment value valid feedback signal / Adj val valid FS
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2526.9
p2663
BI: EPOS clamping active feedback signal / Clamping act FS
SERVO (EPOS),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (EPOS),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3616
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2526.8
r2665
CO: EPOS position setpoint / s_set
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3635
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
r2666
CO: EPOS velocity setpoint / v_set
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3635
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [1000 LU/min]
- [1000 LU/min]
- [1000 LU/min]
Machine data and parameters
1312
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2667
CO: EPOS backlash compensation value / Backlash value
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3635
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
r2669
CO/BO: EPOS actual operating mode / Op mode act
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3625, 3630
VECTOR (EPOS),
P-Group: Basic positioner
Unit group: -
Unit selection: -
VECTOR_AC (EPOS)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2670.0...15
CO/BO: EPOS status word active traversing block / ZSW act trav_blk
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3615, 3625,
VECTOR (EPOS),
3650
VECTOR_AC (EPOS)
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2671
CO: EPOS actual position setpoint / s_set act
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3610, 3616,
VECTOR (EPOS),
3620
VECTOR_AC (EPOS)
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [LU]
- [LU]
- [LU]
r2672
CO: EPOS actual velocity setpoint / v_set act
SERVO (EPOS),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (EPOS),
Data type: Integer32
Dynamic index: -
Function diagram: 3610, 3612,
VECTOR (EPOS),
3616, 3620
VECTOR_AC (EPOS)
P-Group: Basic positioner
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [1000 LU/min]
- [1000 LU/min]
- [1000 LU/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1313
|
||
|
|
|