SINUMERIK 840D sl. Service - Configuring Commissioning. Manual (2011-2020) - page 18

 

 

SINAMICS parameters
3.2 SINAMICS parameters
p1811
Pulse frequency wobbulation amplitude / Puls wobb ampl
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [%]
20 [%]
0 [%]
p1812
BI: Offset calibration output current measurement / Offs_cal I_outp
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 4
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1813[0...2]
Current limitation thresholds / I_limit thresh
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [%]
400 [%]
[0] 100 [%]
[1] 20 [%]
[2] 5 [%]
p1814[0...n]
Vdc filter dead band for modulation switchover / Vdc filt dead band
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
12.0 [%]
0.0 [%]
p1815
Phase for PWM generation subgroup / Ph for PWM subgr
A_INF, R_INF, S_INF,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO, SERVO_AC,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
VECTOR, VECTOR_AC
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0001 bin
Machine data and parameters
1176
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1816
Set phase for PWM generation manually / Set Ph for PWM
A_INF, R_INF, S_INF,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO, SERVO_AC,
Data type: Integer16
Dynamic index: -
Function diagram: -
VECTOR, VECTOR_AC
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1
16
-1
p1817
Pulse frequency to output frequency ratio minimum / f_pulse/f_outp min
SERVO, SERVO_AC
Can be changed: C2(2)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
8.3
15.0
12.0
p1817
Pulse frequency to output frequency ratio minimum / f_pulse/f_outp min
VECTOR, VECTOR_AC
Can be changed: C2(2)
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
8.3
15.0
12.0
p1818
Phase for PWM generation configuration / Ph for PWM config
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Modulation
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
1
p1819
Phase for PWM generation / Ph for PWM
S_INF, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1
16
-1
p1819
Phase for PWM generation / Ph for PWM
A_INF, R_INF
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1
16
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1177
SINAMICS parameters
3.2 SINAMICS parameters
p1820[0...n]
Invert output voltage / U_output inv
HLA
Can be changed: C2(3)
Calculated: CALC_MOD_CON
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 4966
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1820[0...n]
Reverse the output phase sequence / Outp_ph_seq rev
VECTOR, VECTOR_AC
Can be changed: C2(3)
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 6732
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1821[0...n]
Direction / Direction
HLA
Can be changed: C2(3)
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1821[0...n]
Direction of rotation / Dir of rot
SERVO, SERVO_AC
Can be changed: C2(3)
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 4704, 4710,
4711, 4715, 5730, 6730, 6731,
6732
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1821[0...n]
Direction / Direction
SERVO (Lin),
Can be changed: C2(3)
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 4704, 4710,
4711, 4715, 5730, 6730, 6731,
6732
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
1178
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1821[0...n]
Direction of rotation / Dir of rot
VECTOR, VECTOR_AC
Can be changed: C2(3)
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: 4704, 4710,
4711, 4715, 5730, 6730, 6731,
6732
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1821[0...n]
Direction of rotation / Dir of rot
VECTOR (n/M),
Can be changed: C2(3)
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: 4704, 4710,
4711, 4715, 5730, 6730, 6731,
6732
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1822
Power unit line phases monitoring tolerance time / PU ph mon t_tol
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 4
VECTOR, VECTOR_AC
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
500 [ms]
540000 [ms]
1000 [ms]
p1824[0...5]
Common mode compensation / Common mode comp
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-5.00 [µs]
5.00 [µs]
0.00 [µs]
p1824[0...5]
Common mode compensation / Common mode comp
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-5.00 [µs]
5.00 [µs]
0.00 [µs]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1179
SINAMICS parameters
3.2 SINAMICS parameters
p1825
Converter valve threshold voltage / Threshold voltage
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.0 [Vrms]
100.0 [Vrms]
1.0 [Vrms]
p1825
Converter valve threshold voltage / Threshold voltage
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Vrms]
100.0 [Vrms]
0.6 [Vrms]
p1827
Infeed compensation valve lockout time operating mode / INFcomp t_lockMode
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: -
Access level: 4
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1828
Compensation valve lockout time phase U / Comp t_lock ph U
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [µs]
1000000.00 [µs]
0.00 [µs]
p1828
Compensation valve lockout time phase U / Comp t_lock ph U
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
1000000.00 [µs]
0.00 [µs]
p1828
Compensation valve lockout time phase U / Comp t_lock ph U
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
1000000.00 [µs]
0.00 [µs]
Machine data and parameters
1180
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1829
Compensation valve lockout time phase V / Comp t_lock ph V
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [µs]
1000000.00 [µs]
0.00 [µs]
p1829
Compensation valve lockout time phase V / Comp t_lock ph V
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
1000000.00 [µs]
0.00 [µs]
p1829
Compensation valve lockout time phase V / Comp t_lock ph V
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
1000000.00 [µs]
0.00 [µs]
p1830[0...n]
Factor plane adaptation positive / Fact pl_adpt pos
HLA
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4965, 4970,
4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
200.0 [%]
100.0 [%]
p1830
Compensation valve lockout time phase W / Comp t_lock ph W
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [µs]
1000000.00 [µs]
0.00 [µs]
p1830
Compensation valve lockout time phase W / Comp t_lock ph W
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
1000000.00 [µs]
0.00 [µs]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1181
SINAMICS parameters
3.2 SINAMICS parameters
p1830
Compensation valve lockout time phase W / Comp t_lock ph W
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
1000000.00 [µs]
0.00 [µs]
p1831[0...n]
Factor plane adaptation negative / Fact pl_adpt neg
HLA
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965, 4970,
4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
200.0 [%]
100.0 [%]
p1831[0...n]
Dead time compensation changeover signal level to automatic mode / t_dead_comp level
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
3000.00 [Hz]
20.00 [Hz]
p1832[0...n]
Valve offset / Valve offset
HLA
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: 4966
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10.0000 [V]
10.0000 [V]
0.0000 [V]
p1832
Dead time compensation current level / t_dead_comp I_lev
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Arms]
10000.0 [Arms]
0.0 [Arms]
p1832
Dead time compensation current level / t_dead_comp I_lev
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Arms]
10000.0 [Arms]
0.0 [Arms]
Machine data and parameters
1182
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1833[0...n]
Transition point compensation Q1 positive zero range / Trans pt Q1 pos
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4966, 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.01 [%]
95.00 [%]
0.01 [%]
r1833[0...2]
Setpoints phase currents for HW current control / Set_I
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: 6_5
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
p1834[0...n]
Transition point compensation U1 positive zero range / Trans pt U1 pos
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4966, 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
95.00 [%]
0.00 [%]
p1835[0...n]
Transition point compensation rounding 1 positive zero range / Trans pt rnd 1 pos
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4966, 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
30.00 [%]
0.00 [%]
p1835[0...1]
Pulse frequency reduction switchover frequency shift / f_puls_red f_swov
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
800.00 [Hz]
0.00 [Hz]
p1836[0...n]
Transition point compensation Q1 negative zero range / Trans pt Q1 neg
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4966, 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.01 [%]
95.00 [%]
0.01 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1183
SINAMICS parameters
3.2 SINAMICS parameters
r1836[0...1]
Pulse frequency reduction, switchover frequency / f_puls_red f_swov
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
p1837[0...n]
Transition point compensation U1 negative zero range / Trans pt U1 neg
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4966, 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
95.00 [%]
0.00 [%]
r1837
Gating unit configuration / Gating unit config
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1838[0...n]
Transition point compensation rounding 1 negative zero range / Trans pt rnd 1 neg
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4966, 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
30.00 [%]
0.00 [%]
r1838.0...15
CO/BO: Gating unit status word 1 / Gating unit ZSW1
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1838.0...15
CO/BO: Gating unit status word 1 / Gating unit ZSW1
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1184
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1839[0...n]
Transition point compensation Q2 positive / Trans pt Q2 pos
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4966, 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.20 [%]
95.00 [%]
10.00 [%]
r1839.0...15
CO/BO: Gating unit control word 1 / Gating unit STW1
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1839
Gating unit control word 1 / Gating unit STW1
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1840[0...n]
Transition point compensation U2 positive / Trans pt U2 pos
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4966, 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
95.00 [%]
10.00 [%]
p1840[0...n]
Actual value correction configuration / ActV_corr config
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p1840[0...n]
Actual value correction configuration / ActV_corr config
VECTOR (F3E),
Can be changed: T
Calculated: -
Access level: 8
VECTOR_AC (F3E)
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1185
SINAMICS parameters
3.2 SINAMICS parameters
p1841[0...n]
Transition point compensation rounding 2 positive / Trans pt rnd 2 pos
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4966, 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
30.00 [%]
2.50 [%]
r1841
Actual value correction status word / ActV_corr status
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1842[0...n]
Transition point compensation Q2 negative / Trans pt Q2 neg
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4966, 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
95.00 [%]
10.00 [%]
p1843[0...n]
Transition point compensation U2 negative / Trans pt U2 neg
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4966, 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
95.00 [%]
10.00 [%]
p1844[0...n]
Transition point compensation rounding 2 negative / Trans pt rnd 2 neg
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4966, 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
30.00 [%]
2.50 [%]
p1845[0...n]
Transition point compensation Q3 positive saturation / TransPt Q3 pos sat
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.20 [%]
100.00 [%]
100.00 [%]
Machine data and parameters
1186
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1845[0...n]
Actual value correction evaluation factor Lsig / ActV_corr ev Lsig
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
10.00
1.00
p1846[0...n]
Transition point compensation U3 positive saturation / TransPt U3 pos sat
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.20 [%]
100.00 [%]
100.00 [%]
p1846[0...n]
Actual value correction damping factor / ActV_corr D_factor
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
10.00
1.00
p1847[0...n]
Transition point compensation Q3 negative saturation / TransPt Q3 neg sat
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.20 [%]
100.00 [%]
100.00 [%]
p1848[0...n]
Transition point compensation U3 negative saturation / TransPt U3 neg sat
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4975
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.20 [%]
100.00 [%]
100.00 [%]
r1848[0...5]
Actual value correction phase currents / ActV_corr I_ph
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1187
SINAMICS parameters
3.2 SINAMICS parameters
r1849[0...5]
Actual value correction phase voltages / ActV_corr U_ph
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1850[0...n]
Control voltage limiting positive / U_ctrl limit pos
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4966
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [V]
10.0 [V]
10.0 [V]
p1851[0...n]
Control voltage limiting negative / U_ctrl limit neg
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4966
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10.0 [V]
0.0 [V]
-10.0 [V]
r1858.0...15
CO/BO: Status word 1 / ZSW1
HLA
Can be changed: -
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1859.0...15
CO/BO: Gating unit control word 1 / Gating unit STW1
HLA
Can be changed: -
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1882
Gating unit Flattop modulation angle offset / Flattop angle
A_INF (SW_gating
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 4
unit), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(SW_gating unit)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
10000.0 [ms]
80.0 [ms]
Machine data and parameters
1188
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1883[0...4]
SW_sts test voltage input / SW_gu U_test_input
A_INF (SW_gating
Can be changed: T, U
Calculated: -
Access level: 8
unit), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: Displays, signals
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
0.00
16000.00
0.00
r1884
SW_gating unit pulse number for optimized pulse patterns / PulsNo OptPulsPat
A_INF (SW_gating
Can be changed: -
Calculated: -
Access level: 8
unit), R_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: -
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
-
-
-
r1885
SW_gating unit number of written pointers / Qty writ pointer
A_INF (SW_gating
Can be changed: -
Calculated: -
Access level: 8
unit), R_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: -
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
-
-
-
r1886
SW_gating unit angular difference for optimized pulse patterns / Ang_dif OptPulsPat
VECTOR (SW_gating
Can be changed: -
Calculated: -
Access level: 8
unit), VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(SW_gating unit)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1886[0...2]
Gating unit angle actual values / Gat_unit act ang
A_INF (SW_gating
Can be changed: -
Calculated: -
Access level: 8
unit), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(SW_gating unit)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1887
SW_gating unit pulse pattern time at modulation limit / PulsPat t mod_lim
A_INF (SW_gating
Can be changed: -
Calculated: -
Access level: 8
unit), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: -
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1189
SINAMICS parameters
3.2 SINAMICS parameters
r1888
SW_gating unit pulse pattern at the modulation limit / PulsPat mod_lim
A_INF (SW_gating
Can be changed: -
Calculated: -
Access level: 8
unit), R_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: -
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
-
-
-
r1889
SW_gating unit status / status
A_INF (SW_gating
Can be changed: -
Calculated: -
Access level: 8
unit), R_INF
Data type: Unsigned32
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: -
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
-
-
-
p1890
SW_gating unit frequency forced SVM / Frequency SVM
A_INF (SW_gating
Can be changed: T, U
Calculated: -
Access level: 8
unit), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: -
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
0 [Hz]
650 [Hz]
0 [Hz]
p1891
SW_gating unit modulation depth forced SVM / Mod_depth SVM
A_INF (SW_gating
Can be changed: T, U
Calculated: -
Access level: 8
unit), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: -
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
0.0 [%]
100.0 [%]
100.0 [%]
p1892
SW_gating unit hysteresis for frequency forced SVM / Hyst f SVM
A_INF (SW_gating
Can be changed: T, U
Calculated: -
Access level: 8
unit), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: -
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
0.5 [Hz]
20.0 [Hz]
4.0 [Hz]
p1893
SW_gating unit hysteresis for modulation depth forced SVM / Hyst mod_depth SVM
A_INF (SW_gating
Can be changed: T, U
Calculated: -
Access level: 8
unit), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: -
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
0.5 [%]
10.0 [%]
2.0 [%]
Machine data and parameters
1190
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1894
SW_gu control word / SW_gu STW
A_INF (SW_gating
Can be changed: T, U
Calculated: -
Access level: 8
unit), R_INF
Data type: Unsigned32
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: -
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p1895[0...1]
SW_gating unit dynamic limitation angle optimized pulse pattern / Dyn_lim OptPulsPat
A_INF (SW_gating
Can be changed: T, U
Calculated: -
Access level: 8
unit), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: -
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
0.1
1.0
0.5
r1896[0...13]
SW_gating unit U/f table status / Status Uf tab
A_INF (SW_gating
Can be changed: -
Calculated: -
Access level: 8
unit), R_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: Displays, signals
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
-
-
-
r1897
SW_gating unit fault status / Fault status
A_INF (SW_gating
Can be changed: -
Calculated: -
Access level: 8
unit), R_INF
Data type: Unsigned32
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: -
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
-
-
-
p1898
SW_gating unit U/f table number / SW_sts Uf tab No
A_INF (SW_gating
Can be changed: T
Calculated: -
Access level: 8
unit), R_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
(SW_gating unit),
P-Group: -
Unit group: -
Unit selection: -
VECTOR (SW_gating
unit), VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
(SW_gating unit)
Min:
Max:
Factory setting:
0
31
0
p1900
Motor data identification and rotating measurement / MotID and rot meas
SERVO, SERVO_AC
Can be changed: C2(1), T
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
3
2
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1191
SINAMICS parameters
3.2 SINAMICS parameters
p1900
Motor data identification and velocity controller optimization / MotID and rot meas
SERVO (Lin),
Can be changed: C2(1), T
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
3
2
p1900
Motor data identification and rotating measurement / MotID and rot meas
VECTOR, VECTOR_AC
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
2
p1900
Motor data identification and rotating measurement / MotID and rot meas
VECTOR (n/M),
Can be changed: C2(1), T
Calculated: -
Access level: 1
VECTOR_AC (n/M)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
2
p1901
Test pulse evaluation configuration / Test puls config
VECTOR, VECTOR_AC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
r1902
Test pulse evaluation status / Test puls ev stat
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1903
BI: Data identification control / Data ID ctrl
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
1192
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1905
Parameter tuning selection / Par tuning select
VECTOR (n/M),
Can be changed: C2(1), T
Calculated: -
Access level: 1
VECTOR_AC (n/M)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
90
0
p1908[0...n]
Motor data identification modulated voltage generation / MotID U_gen mod
VECTOR, VECTOR_AC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 8
Data type: Unsigned32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p1909
Data identification without enabling activation / Data ID w/o enab
HLA
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p1909[0...n]
Motor data identification control word / MotID STW
SERVO, SERVO_AC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0010 0111 0000 0000 bin
p1909[0...n]
Motor data identification control word / MotID STW
SERVO (Ext M_ctrl, Lin),
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Ext M_ctrl,
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
Lin)
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0110 0111 0000 0000 bin
p1909[0...n]
Motor data identification control word / MotID STW
SERVO (Ext M_ctrl),
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Ext M_ctrl) Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0110 0111 0000 0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1193
SINAMICS parameters
3.2 SINAMICS parameters
p1909[0...n]
Motor data identification control word / MotID STW
SERVO (Lin),
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0010 0111 0000 0000 bin
p1909[0...n]
Motor data identification control word / MotID STW
VECTOR, VECTOR_AC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
Data type: Unsigned32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
p1910
Valve offset calibration standstill activation / Valv_off_cal act
HLA
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1910
Motor data identification routine stationary (standstill) / MotID standstill
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-3
1
0
p1910
Motor data identification selection / MotID selection
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
28
1
p1911
Phases to be identified number / Ph to ident qty
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 4
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
3
1
Machine data and parameters
1194
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1912
Stator resistance identified / R_stator ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
r1912[0...2]
Stator resistance identified / R_stator ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
r1913
Rotor time constant identified / Tc_rotor ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: PMSM, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
r1913[0...2]
Rotor time constant identified / Tc_rotor ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: PMSM, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
r1914[0...2]
Total leakage inductance identified / L_total_leak ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r1915
Stator inductance identified / L_stator ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1195
SINAMICS parameters
3.2 SINAMICS parameters
r1915[0...2]
Nominal stator inductance identified / L_stator nom ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r1916[0...2]
Identified stator inductance 1 / L_stator 1 ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r1917[0...2]
Identified stator inductance 2 / L_stator 2 ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r1918[0...2]
Identified stator inductance 3 / L_stator 3 ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r1919[0...2]
Identified stator inductance 4 / L_stator 4 ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r1920[0...2]
Identified dynamic leakage inductance / L_leak dyn ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
Machine data and parameters
1196
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1921[0...2]
Identified dynamic leakage inductance 1 / L_leak 1 dyn ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r1922[0...2]
Identified dynamic leakage inductance 2 / L_leak 2 dyn ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r1923[0...2]
Identified dynamic leakage inductance 3 / L_leak 3 dyn ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r1924[0...2]
Identified dynamic leakage inductance 4 / L_leak 4 dyn ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r1925
Threshold voltage identified / U_threshold ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
r1925[0...2]
Identified threshold voltage / U_threshold ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1197
SINAMICS parameters
3.2 SINAMICS parameters
r1926[0...2]
Active valve interlock time identified / t_lock_valve ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [µs]
- [µs]
- [µs]
r1927
Rotor resistance identified / R_rotor ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
r1927[0...2]
Rotor resistance identified / R_rotor ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
r1929[0...2]
Identified cable resistance / R_cable ident
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
p1931
Test voltage phase / U_test phase
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
12
1
r1932[0...19]
d inductance identified / Ld ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
Machine data and parameters
1198
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1933[0...19]
d inductance identification current / Ld I_ID
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r1934[0...9]
q inductance identified / Lq ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r1934[0...9]
q inductance identified / Lq ident
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r1935[0...20]
Identification current / I_ID
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r1935[0...20]
Identification current / I_ID
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r1935[0...9]
q inductance identification current / Lq I_ID
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1199
SINAMICS parameters
3.2 SINAMICS parameters
r1936
Magnetizing inductance identified / L_H ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r1937[0...10]
Torque constant identified / kT ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: 28_1
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Nm/A]
- [Nm/A]
- [Nm/A]
r1937[0...10]
Force constant identified / kT ident
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: 29_1
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [N/Arms]
- [N/Arms]
- [N/Arms]
r1938
Voltage constant identified / kE ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
r1938
Voltage constant identified / kE ident
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms s/m]
- [Vrms s/m]
- [Vrms s/m]
r1939
Reluctance torque constant identified / kT_reluct ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
Machine data and parameters
1200
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1939
Reluctance force constant identified / kT_reluct ident
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r1947
Optimum load angle identified / phi_load ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
r1948
Magnetizing current identified / I_mag ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r1949.0...1
CO/BO: Status word data identification / ZSW data ID
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1950[0...39]
Voltage emulation error voltage values / U_error U_values
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r1951[0...19]
Voltage emulation error current values / U_error I_error
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1201
SINAMICS parameters
3.2 SINAMICS parameters
p1952[0...n]
Voltage emulation error final value / U_error final val
SERVO (Ext M_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext M_ctrl)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [V]
100.000 [V]
0.000 [V]
p1953[0...n]
Voltage emulation error current offset / U_error I_offset
SERVO (Ext M_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext M_ctrl)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [A]
100.000 [A]
0.000 [A]
p1954[0...n]
Voltage emulation error semiconductor voltage / U_error U_semi
SERVO (Ext M_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext M_ctrl)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10.000 [V]
10.000 [V]
0.000 [V]
p1955[0...3]
Valve identification voltage / Valve ID U
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [V]
10.00 [V]
[0] 0.00 [V]
[1] 10.00 [V]
[2] 2.00 [V]
[3] 2.00 [V]
p1955[0...n]
Voltage generation alternating base voltage amplitude / U_gen altern base
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1.00 [V]
100.00 [V]
0.00 [V]
Machine data and parameters
1202
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1956[0...1]
Valve identification measuring distance / Valve ID dist
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
100.0 [%]
[0] 10.0 [%]
[1] 90.0 [%]
p1957[0...1]
Valve identification measured value / Valve ID val
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1000
[0] 100
[1] 4
p1958[0...4]
Valve identification time / Valve ID t
HLA
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [s]
100.00 [s]
[0] 0.10 [s]
[1] 0.10 [s]
[2] 0.10 [s]
[3] 4.00 [s]
[4] 4.00 [s]
p1958[0...n]
Rotating measurement ramp-up/ramp-down time / Rot meas t_r up/dn
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1.00 [s]
999999.00 [s]
-1.00 [s]
p1958[0...n]
Moving measurement ramp-up/ramp-down time / Mov meas t_r up/dn
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1.00 [s]
999999.00 [s]
-1.00 [s]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1203
SINAMICS parameters
3.2 SINAMICS parameters
p1959[0...n]
Data identification moving configuration / Dat_ID mov config
HLA
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 2
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0001 0011 1111 bin
p1959[0...n]
Rotating measurement configuration / Rot meas config
SERVO, SERVO_AC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 1110 1110 0111 bin
p1959[0...n]
Moving measurement configuration / Mov meas config
SERVO (Lin),
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 1110 1110 0111 bin
p1959[0...n]
Rotating measurement configuration / Rot meas config
VECTOR (n/M),
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 2
VECTOR_AC (n/M)
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0001 1111 bin
p1960
Moving measurement selection / Mov meas sel
HLA
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-3
1
0
p1960
Rotating measurement selection / Rot meas sel
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-3
1
0
Machine data and parameters
1204
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1960
Moving measurement selection / Mov meas sel
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-3
1
0
p1960
Rotating measurement selection / Rot meas sel
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4
0
r1961[0...511]
Valve identification voltage characteristic / Valve ID char U
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p1961
Saturation characteristic speed to determine / Sat_char n determ
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
26 [%]
75 [%]
40 [%]
r1962[0...511]
Valve identification characteristic velocity / Valve ID char v
HLA
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1962[0...9]
Saturation characteristic magnetizing current identified / Sat_char I_mag
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1205
SINAMICS parameters
3.2 SINAMICS parameters
r1962[0...4]
Saturation characteristic magnetizing current / Sat_char I_mag
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r1963[0...511]
Valve identification system pressure characteristic / Valve ID char pp
HLA
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [bar]
- [bar]
- [bar]
r1963[0...9]
Saturation characteristic rotor flux identified / Sat_char flux
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mVs]
- [mVs]
- [mVs]
r1963[0...4]
Saturation characteristic magnetizing inductance / Sat_char L_main
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r1964[0...511]
Valve identification characteristic force / Valve ID char F
HLA
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: 8_1
Unit selection: p0505
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [N]
- [N]
- [N]
r1964[0...4]
Saturation characteristic rotor flux / Sat_char rot flux
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
Machine data and parameters
1206
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1965
Speed_ctrl_opt speed / n_opt speed
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10 [%]
75 [%]
40 [%]
p1967
Speed_ctrl_opt dynamic factor / n_opt dyn_factor
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [%]
400 [%]
100 [%]
r1968
Speed_ctrl_opt dynamic factor actual / n_opt dyn_fact act
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r1969
Moment of inertia identified / M_inert ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: 25_1
Unit selection: p0100
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kgm²]
- [kgm²]
- [kgm²]
r1969
High load inertia identified / High load inert id
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: 27_1
Unit selection: p0100
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kg]
- [kg]
- [kg]
r1969
Speed_ctrl_opt moment of inertia determined / n_opt m_inert det
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: 25_1
Unit selection: p0100
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kgm²]
- [kgm²]
- [kgm²]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1207
SINAMICS parameters
3.2 SINAMICS parameters
r1970[0...1]
Speed_ctrl_opt vibration test vibration frequency determined / n_opt f_vib det
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
r1971[0...1]
Speed_ctrl_opt vibration test standard deviation determined / n_opt std_dev det
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
r1972[0...1]
Speed_ctrl_opt vibration test number of periods determined / n_opt per_qty det
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1973[0...1]
Encoder pulse number identified / Pulse no ident
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1973
Rotating measurement encoder test pulse number determined / n_opt puls no det
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Integer32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1974
Speed_ctrl_opt saturation characteristic rotor flux maximum / n_opt rot_fl max
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
104 [%]
120 [%]
120 [%]
Machine data and parameters
1208
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1979.0...12
BO: Speed_ctrl_opt status / n_opt status
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1980[0...n]
PolID technique / PolID technique
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
99
99
p1980[0...n]
PolID technique / PolID technique
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 3
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
12
4
p1981[0...n]
PolID distance max / PolID distance max
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [°]
180 [°]
10 [°]
p1982[0...n]
PolID selection / PolID selection
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p1982[0...n]
PolID selection / PolID selection
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1209
SINAMICS parameters
3.2 SINAMICS parameters
p1983
PolID test / PolID test
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1983
PolID test / PolID test
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4
0
r1984
PolID angular difference / PolID ang diff
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
r1984
PolID angular difference / PolID ang diff
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
r1985
ChId v/U characteristic velocity measured / ChId v/U v meas
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1985
PolID saturation curve / PolID sat_char
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
Machine data and parameters
1210
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1985
PolID saturation curve / PolID sat_char
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r1986
ChId v/U characteristic velocity parameterized / ChId v/U v par
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1986
PolID saturation characteristic 2 / PoleID sat_curve 2
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1987
ChId v/U characteristic voltage / ChId v/U U
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r1987
PolID trigger characteristic / PolID trig_char
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r1987
PolID trigger characteristic / PolID trig_char
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1211
SINAMICS parameters
3.2 SINAMICS parameters
p1990
Encoder adjustment determine angular commutation offset / Enc_adj det ang
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1990
Encoder adjustment determine angular commutation offset / Enc_adj det ang
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
p1991[0...n]
Motor changeover angular commutation correction / Ang_com corr
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-180 [°]
180 [°]
0 [°]
p1991[0...n]
Motor changeover angular commutation correction / Ang_com corr
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: ASM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-180 [°]
180 [°]
0 [°]
r1992.0...15
CO/BO: PolID diagnostics / PolID diag
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1992.0...15
CO/BO: PolID diagnostics / PolID diag
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1212
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1992.0...15
CO/BO: PolID diagnostics / PolID diag
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 8
VECTOR_AC (n/M)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1993[0...n]
PolID motion-based current / PolID I mtn_bas
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
20000.00 [Arms]
0.00 [Arms]
p1994[0...n]
PolID motion-based rise time / PolID T mtn_bas
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
2500 [ms]
100 [ms]
p1995[0...n]
PolID motion-based gain / PolID kp mtn_bas
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: 17_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0000 [Nms/rad]
999999.0000 [Nms/rad]
0.3000 [Nms/rad]
p1995[0...n]
PolID motion-based gain / PolID kp mtn_bas
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: 24_2
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0000 [Ns/m]
999999.0000 [Ns/m]
10.0000 [Ns/m]
p1996[0...n]
PolID motion-based integral time / PolID Tn mtn_bas
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
500.0 [ms]
2.0 [ms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1213
SINAMICS parameters
3.2 SINAMICS parameters
p1997[0...n]
PolID motion-based smoothing time / PolID t_sm mtn_bas
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
50.0 [ms]
0.0 [ms]
p1998[0...n]
PolID circle center point / PolID circ center
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0000 [A]
10000.0000 [A]
0.0000 [A]
p1999[0...n]
Ang. commutation offset calibr. and PollD scaling / Com_ang_offs scal
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: ASM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10 [%]
5000 [%]
100 [%]
p2000
Reference velocity / v_ref
HLA
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.600 [m/min]
600.000 [m/min]
120.000 [m/min]
p2000
Reference speed reference frequency / n_ref f_ref
SERVO, SERVO_AC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
6.00 [rpm]
210000.00 [rpm]
3000.00 [rpm]
p2000
Reference velocity reference frequency / v_ref f_ref
SERVO (Lin),
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.60 [m/min]
700.00 [m/min]
120.00 [m/min]
Machine data and parameters
1214
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2000
Reference speed reference frequency / n_ref f_ref
VECTOR, VECTOR_AC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
6.00 [rpm]
210000.00 [rpm]
3000.00 [rpm]
p2000
Reference frequency / f_ref
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 2
S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.10 [Hz]
1000.00 [Hz]
50.00 [Hz]
p2000
Reference speed reference frequency / n_ref f_ref
TM41
Can be changed: T
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
6.00 [rpm]
210000.00 [rpm]
3000.00 [rpm]
p2000
Reference speed reference frequency / n_ref f_ref
ENC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
6.00 [rpm]
210000.00 [rpm]
3000.00 [rpm]
p2000
Reference velocity reference frequency / v_ref f_ref
ENC (Lin_enc)
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.60 [m/min]
600.00 [m/min]
120.00 [m/min]
p2001
Reference voltage / Reference voltage
HLA
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10 [V]
100000 [V]
1000 [V]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1215
SINAMICS parameters
3.2 SINAMICS parameters
p2001
Reference voltage / Reference voltage
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, TM41,
P-Group: Communications
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10 [Vrms]
100000 [Vrms]
1000 [Vrms]
p2002
Reference pressure / p_ref
HLA
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.10 [bar]
5000.00 [bar]
100.00 [bar]
p2002
Reference current / I_ref
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, TM41,
P-Group: Communications
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.10 [Arms]
100000.00 [Arms]
100.00 [Arms]
p2003
Reference force / F_ref
HLA
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: 8_2
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.01 [N]
20000000.00 [N]
100.00 [N]
p2003
Reference torque / M_ref
SERVO, SERVO_AC,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
TM41, VECTOR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Communications
Unit group: 7_2
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.01 [Nm]
20000000.00 [Nm]
1.00 [Nm]
p2003
Reference force / Reference force
SERVO (Lin),
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: 8_2
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.01 [N]
20000000.00 [N]
100.00 [N]
Machine data and parameters
1216
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2003
Reference torque / M_ref
A_INF, B_INF, R_INF
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.01 [Nm]
20000000.00 [Nm]
1.00 [Nm]
p2003
Reference torque / M_ref
S_INF
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.01 [Nm]
20000000.00 [Nm]
1.00 [Nm]
r2004
Reference power / P_ref
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: 14_10
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r2004
Reference power / P_ref
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, TM41,
P-Group: Communications
Unit group: 14_10
Unit selection: p0505
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
p2005
Reference angle / Reference angle
A_INF, B_INF, HLA,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
R_INF, S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, TM41,
P-Group: Communications
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
90.00 [°]
180.00 [°]
90.00 [°]
p2006
Reference temperature / Ref temp
TM120, TM150, TM31
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.00 [°C]
300.00 [°C]
100.00 [°C]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1217
SINAMICS parameters
3.2 SINAMICS parameters
p2006
Reference temperature / Ref temp
A_INF, B_INF, HLA,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
R_INF, S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, TM41,
P-Group: Communications
Unit group: 21_1
Unit selection: p0505
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.00 [°C]
300.00 [°C]
100.00 [°C]
p2007
Reference acceleration / a_ref
SERVO, SERVO_AC,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
TM41, VECTOR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.01 [rev/s²]
500000.00 [rev/s²]
0.01 [rev/s²]
p2007
Reference acceleration / a_ref
HLA, SERVO (Lin),
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: 22_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.01 [m/s²]
10000.00 [m/s²]
0.01 [m/s²]
r2019[0...7]
Comm IF error statistics / Comm err
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2020
Field bus interface baud rate / Field bus baud
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 2
CU_S120_DP
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
4
8
8
p2020
Field bus interface baud rate / Field bus baud
CU_S_AC_PN,
Can be changed: T
Calculated: -
Access level: 8
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
4
8
8
Machine data and parameters
1218
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2021
Field bus interface address / Field bus address
CU_S_AC_PN,
Can be changed: T
Calculated: -
Access level: 8
CU_S120_PN
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
31
0
p2021
Field bus interface address / Field bus address
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 2
CU_S120_DP
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
31
0
p2022
Field bus int USS PZD no. / Field bus USS PZD
CU_S_AC_PN,
Can be changed: T
Calculated: -
Access level: 8
CU_S120_PN
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
16
2
p2022
Field bus int USS PZD no. / Field bus USS PZD
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 2
CU_S120_DP
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
16
2
p2023
Field bus interface USS PKW count / Field bus USS PKW
CU_S_AC_PN,
Can be changed: T
Calculated: -
Access level: 8
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
127
127
p2023
Field bus interface USS PKW count / Field bus USS PKW
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 2
CU_S120_DP
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
127
127
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1219
SINAMICS parameters
3.2 SINAMICS parameters
p2024[0...2]
Fieldbus interface times / Fieldbus times
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
10000 [ms]
[0] 1000 [ms]
[1] 0 [ms]
[2] 0 [ms]
r2029[0...7]
Field bus interface error statistics / Field bus error
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 8
CU_S120_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2029[0...7]
Field bus interface error statistics / Field bus error
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_DP
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2030
Field bus interface protocol selection / Field bus protocol
CU_S_AC_PN,
Can be changed: T
Calculated: -
Access level: 1
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
7
13
7
p2030
Field bus interface protocol selection / Field bus protocol
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 1
CU_S120_DP
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
3
6
3
Machine data and parameters
1220
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2031
Fieldbus interface MODBUS parity / Modbus parity
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 9
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: 9310
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
2
2
r2032
Master control control word effective / PcCtrl STW eff
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2032
Master control control word effective / PcCtrl STW eff
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2032
Master control control word effective / PcCtrl STW eff
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 2
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2035
Fieldbus interface USS PIV drive object number / Fieldbus USS DO_no
CU_S_AC_PN,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
62
2
p2035
Fieldbus interface USS PIV drive object number / Fieldbus USS DO_no
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S120_DP
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
62
2
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1221
SINAMICS parameters
3.2 SINAMICS parameters
p2037
IF1 PROFIdrive STW1.10 = 0 mode / IF1 PD STW1.10=0
A_INF, B_INF, ENC,
Can be changed: T
Calculated: -
Access level: 3
HLA, R_INF, S_INF,
Data type: Integer16
Dynamic index: -
Function diagram: -
SERVO, SERVO_AC,
P-Group: Communications
Unit group: -
Unit selection: -
TM41, VECTOR,
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p2038
IF1 PROFIdrive STW/ZSW interface mode / PD STW/ZSW IF mode
HLA
Can be changed: T
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
1
1
p2038
IF1 PROFIdrive STW/ZSW interface mode / PD STW/ZSW IF mode
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p2038
IF1 PROFIdrive STW/ZSW interface mode / PD STW/ZSW IF mode
SERVO (EPOS, Pos ctrl,
Can be changed: T
Calculated: -
Access level: 3
Pos ctrl), SERVO_AC
Data type: Integer16
Dynamic index: -
Function diagram: -
(EPOS, Pos ctrl, Pos ctrl)
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
0
0
p2038
IF1 PROFIdrive STW/ZSW interface mode / PD STW/ZSW IF mode
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p2038
IF1 PROFIdrive STW/ZSW interface mode / PD STW/ZSW IF mode
VECTOR (EPOS, Pos ctrl,
Can be changed: T
Calculated: -
Access level: 3
Pos ctrl), VECTOR_AC
Data type: Integer16
Dynamic index: -
Function diagram: -
(EPOS, Pos ctrl, Pos ctrl)
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
0
0
Machine data and parameters
1222
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2039
Select debug monitor interface / Debug mon select
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
p2040
Fieldbus interface monitoring time / Fieldbus t_mon
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1999999 [ms]
100 [ms]
p2041[0...4]
PROFIBUS detail settings / PB detail
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p2042
PROFIBUS Ident Number / PB ident no
CU_S_AC_PN,
Can be changed: T
Calculated: -
Access level: 8
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p2042
PROFIBUS Ident Number / PB ident no
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 3
CU_S120_DP
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
r2043.0...2
BO: IF1 PROFIdrive PZD state / IF1 PD PZD state
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: 2410
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1223
SINAMICS parameters
3.2 SINAMICS parameters
p2044
IF1 PROFIdrive fault delay / IF1 PD fault delay
A_INF, B_INF, ENC,
Can be changed: T, U
Calculated: -
Access level: 3
HLA, R_INF, S_INF,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2410
SERVO, SERVO_AC,
P-Group: Communications
Unit group: -
Unit selection: -
TM41, VECTOR,
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [s]
100 [s]
0 [s]
p2045
CI: PB/PN clock synchronous controller sign-of-life signal source / PB/PN ctr SoL s_s
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 2410
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HLA, SERVO,
Not for motor type: -
Scaling: -
Expert list: 1
SERVO_AC, TM41,
Min:
Max:
Factory setting:
VECTOR (n/M),
-
-
0
VECTOR_AC (n/M)
p2047
PROFIBUS additional monitoring time / PB suppl t_mon
CU_S_AC_PN,
Can be changed: T, U
Calculated: -
Access level: 8
CU_S120_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
20000 [ms]
0 [ms]
p2047
PROFIBUS additional monitoring time / PB suppl t_mon
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S120_DP
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
20000 [ms]
0 [ms]
p2048
IF1 PROFIdrive PZD sampling time / IF1 PZD t_samp
CU_S_AC_DP,
Can be changed: C1(3)
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.00 [ms]
16.00 [ms]
4.00 [ms]
p2049
PROFIdrive isochronous operation asynchronous participation / Isochron async
SERVO, VECTOR
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
1224
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2050[0...19]
CO: IF1 PROFIdrive PZD receive word / IF1 PZD recv word
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2050[0...21]
CO: IF1 PROFIdrive PZD receive word / IF1 PZD recv word
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Integer16
Dynamic index: -
Function diagram: 2440, 2468
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2050[0...31]
CO: IF1 PROFIdrive PZD receive word / IF1 PZD recv word
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 2440, 2468
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2050[0...9]
CO: IF1 PROFIdrive PZD receive word / IF1 PZD recv word
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2050[0...4]
CO: IF1 PROFIdrive PZD receive word / IF1 PZD recv word
TB30, TM120, TM150,
Can be changed: -
Calculated: -
Access level: 3
TM15DI_DO, TM31
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2050[0...3]
CO: IF1 PROFIdrive PZD receive word / IF1 PZD recv word
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 2440, 2468
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1225
SINAMICS parameters
3.2 SINAMICS parameters
p2051[0...24]
CI: IF1 PROFIdrive PZD send word / IF1 PZD send word
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2051[0...27]
CI: IF1 PROFIdrive PZD send word / IF1 PZD send word
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 2470
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2051[0...31]
CI: IF1 PROFIdrive PZD send word / IF1 PZD send word
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 2470
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2051[0...9]
CI: IF1 PROFIdrive PZD send word / IF1 PZD send word
A_INF, B_INF, R_INF,
Can be changed: T, U
Calculated: -
Access level: 3
S_INF
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2051[0...4]
CI: IF1 PROFIdrive PZD send word / IF1 PZD send word
TB30, TM120, TM150,
Can be changed: T, U
Calculated: -
Access level: 3
TM15DI_DO, TM31
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2051[0...11]
CI: IF1 PROFIdrive PZD send word / IF1 PZD send word
ENC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 2470
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1226
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2053[0...24]
IF1 PROFIdrive diagnostics PZD send word / IF1 diag send word
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2053[0...27]
IF1 PROFIdrive diagnostics PZD send word / IF1 diag send word
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Unsigned16
Dynamic index: -
Function diagram: 2450, 2470
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2053[0...31]
IF1 PROFIdrive diagnostics PZD send word / IF1 diag send word
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2450, 2470
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2053[0...9]
IF1 PROFIdrive diagnostics PZD send word / IF1 diag send word
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2053[0...4]
IF1 PROFIdrive diagnostics PZD send word / IF1 diag send word
TB30, TM120, TM150,
Can be changed: -
Calculated: -
Access level: 3
TM15DI_DO, TM31
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2053[0...11]
IF1 PROFIdrive diagnostics PZD send word / IF1 diag send word
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2450, 2470
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1227
SINAMICS parameters
3.2 SINAMICS parameters
r2054
PROFIBUS status / PB status
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 8
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4
-
r2054
PROFIBUS status / PB status
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_DP
Data type: Integer16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4
-
r2055[0...2]
PROFIBUS diagnostics standard / PB diag standard
CU_S_AC_PN
Can be changed: -
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2055[0...2]
PROFIBUS diagnostics standard / PB diag standard
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
CU_S120_PN
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2056[0...19]
PROFIBUS diagnostics expert / PB diag experts
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2057
PROFIBUS address switch diagnostics / PB addr sw diag
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 8
CU_S120_PN
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1228
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2057
PROFIBUS address switch diagnostics / PB addr sw diag
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_DP
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2060[0...20]
CO: IF1 PROFIdrive PZD receive double word / IF1 PZD recv DW
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Integer32
Dynamic index: -
Function diagram: 2440, 2468
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2060[0...30]
CO: IF1 PROFIdrive PZD receive double word / IF1 PZD recv DW
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: -
Function diagram: 2440, 2468
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2060[0...2]
CO: IF1 PROFIdrive PZD receive double word / IF1 PZD recv DW
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: -
Function diagram: 2440, 2468
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2061[0...26]
CI: IF1 PROFIdrive PZD send double word / IF1 PZD send DW
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 2470
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2061[0...30]
CI: IF1 PROFIdrive PZD send double word / IF1 PZD send DW
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 2470
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1229
SINAMICS parameters
3.2 SINAMICS parameters
p2061[0...10]
CI: IF1 PROFIdrive PZD send double word / IF1 PZD send DW
ENC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 2470
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: 4000H
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r2063[0...26]
IF1 PROFIdrive diagnostics PZD send double word / IF1 diag send DW
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Unsigned32
Dynamic index: -
Function diagram: 2450, 2470
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2063[0...30]
IF1 PROFIdrive diagnostics PZD send double word / IF1 diag send DW
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 2450, 2470
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2063[0...10]
IF1 PROFIdrive diagnostics PZD send double word / IF1 diag send DW
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 2450, 2470
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2064[0...7]
PB/PN diagnostics clock cycle synchronism / PB/PN diag clock
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer32
Dynamic index: -
Function diagram: 2410
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2065
PB/PN controller sign of life diagnostics / PB/PN ctr SoL diag
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HLA, SERVO,
Not for motor type: -
Scaling: -
Expert list: 1
SERVO_AC, TM41,
Min:
Max:
Factory setting:
VECTOR (n/M),
-
-
-
VECTOR_AC (n/M)
Machine data and parameters
1230
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2067[0...1]
IF1 PZD maximum interconnected / IF1 PZDmaxIntercon
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
-
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
p2070
IF1 PROFIdrive supplementary telegram receive beginning / Suppl_tel recv beg
HLA, SERVO, SERVO_AC Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: -
Function diagram: 2423
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
20
0
p2070
IF1 PROFIdrive supplementary telegram receive beginning / Suppl_tel recv beg
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: -
Function diagram: 2423
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
30
0
p2071
IF1 PROFIdrive supplementary telegram send beginning / Suppl_tel send beg
HLA, SERVO, SERVO_AC Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: -
Function diagram: 2423
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
26
0
p2071
IF1 PROFIdrive supplementary telegram send beginning / Suppl_tel send beg
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: -
Function diagram: 2423
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
30
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1231
SINAMICS parameters
3.2 SINAMICS parameters
p2072
IF1 response receive value after PZD failure / Resp aft PZD fail
HLA, TM41
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0001 bin
p2072
IF1 response receive value after PZD failure / Resp aft PZD fail
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
r2074[0...19]
IF1 PROFIdrive diagnostics bus address PZD receive / IF1diag addr recv
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2074[0...21]
IF1 PROFIdrive diagnostics bus address PZD receive / IF1diag addr recv
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2074[0...31]
IF1 PROFIdrive diagnostics bus address PZD receive / IF1diag addr recv
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2074[0...9]
IF1 PROFIdrive diagnostics bus address PZD receive / IF1diag addr recv
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1232
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2074[0...4]
IF1 PROFIdrive diagnostics bus address PZD receive / IF1diag addr recv
TB30, TM120, TM150,
Can be changed: -
Calculated: -
Access level: 3
TM15DI_DO, TM31
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2074[0...3]
IF1 PROFIdrive diagnostics bus address PZD receive / IF1diag addr recv
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2075[0...19]
IF1 PROFIdrive diagnostics telegram offset PZD receive / IF1 diag offs recv
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2075[0...21]
IF1 PROFIdrive diagnostics telegram offset PZD receive / IF1 diag offs recv
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2075[0...31]
IF1 PROFIdrive diagnostics telegram offset PZD receive / IF1 diag offs recv
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2075[0...9]
IF1 PROFIdrive diagnostics telegram offset PZD receive / IF1 diag offs recv
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1233
SINAMICS parameters
3.2 SINAMICS parameters
r2075[0...4]
IF1 PROFIdrive diagnostics telegram offset PZD receive / IF1 diag offs recv
TB30, TM120, TM150,
Can be changed: -
Calculated: -
Access level: 3
TM15DI_DO, TM31
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2075[0...3]
IF1 PROFIdrive diagnostics telegram offset PZD receive / IF1 diag offs recv
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2076[0...24]
IF1 PROFIdrive diagnostics telegram offset PZD send / IF1 diag offs send
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2076[0...27]
IF1 PROFIdrive diagnostics telegram offset PZD send / IF1 diag offs send
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, TM41
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2076[0...31]
IF1 PROFIdrive diagnostics telegram offset PZD send / IF1 diag offs send
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2076[0...9]
IF1 PROFIdrive diagnostics telegram offset PZD send / IF1 diag offs send
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1234
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r2076[0...4]
IF1 PROFIdrive diagnostics telegram offset PZD send / IF1 diag offs send
TB30, TM120, TM150,
Can be changed: -
Calculated: -
Access level: 3
TM15DI_DO, TM31
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2076[0...11]
IF1 PROFIdrive diagnostics telegram offset PZD send / IF1 diag offs send
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2077[0...15]
PROFIBUS diagnostics peer-to-peer data transfer addresses / PB diag peer addr
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 8
CU_S120_PN
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r2077[0...15]
PROFIBUS diagnostics peer-to-peer data transfer addresses / PB diag peer addr
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_DP
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD tel ext
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
390
999
999
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD tel ext
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
166
999
999
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1235
SINAMICS parameters
3.2 SINAMICS parameters
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD tel ext
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
999
999
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD tel ext
SERVO (EPOS, EPOS,
Can be changed: T
Calculated: -
Access level: 3
Pos ctrl, Pos ctrl,
Data type: Integer16
Dynamic index: -
Function diagram: -
Spin_diag), SERVO_AC
P-Group: Communications
Unit group: -
Unit selection: -
(EPOS, EPOS, Pos ctrl,
Pos ctrl, Spin_diag),
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR (EPOS, EPOS,
Min:
Max:
Factory setting:
n/M, Pos ctrl, Pos ctrl),
7
999
999
VECTOR_AC (EPOS,
EPOS, n/M, Pos ctrl, Pos
ctrl)
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD tel ext
SERVO (Pos ctrl, Pos
Can be changed: T
Calculated: -
Access level: 3
ctrl, Spin_diag),
Data type: Integer16
Dynamic index: -
Function diagram: -
SERVO_AC (Pos ctrl, Pos
P-Group: Communications
Unit group: -
Unit selection: -
ctrl, Spin_diag),
VECTOR (n/M, Pos ctrl,
Not for motor type: -
Scaling: -
Expert list: 1
Pos ctrl), VECTOR_AC
Min:
Max:
Factory setting:
(n/M, Pos ctrl, Pos ctrl)
999
999
999
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD tel ext
SERVO (Spin_diag),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Spin_diag)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
999
999
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD tel ext
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
999
999
Machine data and parameters
1236
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD tel ext
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
999
999
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD tel ext
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 3
S_INF
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
370
999
999
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD tel ext
TM41
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
3
999
999
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD tel ext
ENC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
81
999
999
p2080[0...15]
BI: IF1 binector-connector converter status word 1 / IF1 bin/con ZSW1
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2472
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1237
SINAMICS parameters
3.2 SINAMICS parameters
p2081[0...15]
BI: IF1 binector-connector converter status word 2 / IF1 bin/con ZSW2
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2472
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
p2082[0...15]
BI: IF1 binector-connector converter status word 3 / IF1 bin/con ZSW3
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2472
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
p2083[0...15]
BI: IF1 binector-connector converter status word 4 / IF1 bin/con ZSW4
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2472
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
p2084[0...15]
BI: IF1 binector-connector converter status word 5 / IF1 bin/con ZSW5
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2472
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
Machine data and parameters
1238
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2088[0...4]
IF1 invert binector-connector converter status word / Bin/con ZSW inv
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2472
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0000 0000 0000 0000 bin
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
r2089[0...4]
CO: IF1 send binector-connector converter status word / Bin/con ZSW send
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2472
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
-
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
r2090.0...15
BO: IF1 PROFIdrive PZD1 receive bit-serial / PZD1 recv bitw
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2468
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
-
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
r2091.0...15
BO: IF1 PROFIdrive PZD2 receive bit-serial / PZD2 recv bitw
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2468
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
-
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1239
SINAMICS parameters
3.2 SINAMICS parameters
r2092.0...15
BO: IF1 PROFIdrive PZD3 receive bit-serial / PZD3 recv bitw
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2468
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HLA, SERVO,
Not for motor type: -
Scaling: -
Expert list: 1
SERVO_AC, TM41,
Min:
Max:
Factory setting:
VECTOR, VECTOR_AC
-
-
-
r2093.0...15
BO: IF1 PROFIdrive PZD4 receive bit-serial / PZD4 recv bitw
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2468
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HLA, SERVO,
Not for motor type: -
Scaling: -
Expert list: 1
SERVO_AC, TM41,
Min:
Max:
Factory setting:
VECTOR, VECTOR_AC
-
-
-
r2094.0...15
BO: IF1 connector-binector converter binector output / Con/bin outp
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2468
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
-
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
r2095.0...15
BO: IF1 connector-binector converter binector output / Con/bin outp
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2468
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
-
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
p2098[0...1]
IF1 invert connector-binector converter binector output / Con/bin outp inv
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2468
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0000 0000 0000 0000 bin
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
Machine data and parameters
1240
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2099[0...1]
CI: IF1 connector-binector converter signal source / Con/bin s_s
A_INF, B_INF,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 2468
CU_S_AC_PN,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, R_INF, S_INF,
Min:
Max:
Factory setting:
SERVO, SERVO_AC,
-
-
0
TB30, TM120, TM150,
TM15DI_DO, TM31,
TM41, VECTOR,
VECTOR_AC
p2100[0...19]
Change fault response fault number / Chg resp flt_no
All objects
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 8050, 8075
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p2101[0...19]
Change fault response response / Chg resp resp
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: 8050, 8075
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HUB, TB30, TM120,
Not for motor type: -
Scaling: -
Expert list: 1
TM15, TM150,
Min:
Max:
Factory setting:
TM15DI_DO, TM17,
0
0
0
TM31, TM54F_MA,
TM54F_SL
p2101[0...19]
Change fault response response / Chg resp resp
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, TM41,
Data type: Integer16
Dynamic index: -
Function diagram: 8050, 8075
VECTOR, VECTOR_AC
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
7
0
p2101[0...19]
Change fault response response / Chg resp resp
A_INF, B_INF, R_INF,
Can be changed: T, U
Calculated: -
Access level: 3
S_INF
Data type: Integer16
Dynamic index: -
Function diagram: 8050, 8075
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1241
SINAMICS parameters
3.2 SINAMICS parameters
p2102
BI: Acknowledge all faults / Ackn all faults
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2546, 8060
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2103
BI: 1st acknowledge faults / 1st acknowledge
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HUB, TB30, TM120,
Not for motor type: -
Scaling: -
Expert list: 1
TM15, TM150,
Min:
Max:
Factory setting:
TM15DI_DO, TM17,
-
-
0
TM31, TM54F_MA,
TM54F_SL
p2103[0...n]
BI: 1st acknowledge faults / 1st acknowledge
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2441, 2442,
SERVO_AC, TM41,
2443, 2447, 2475, 2546, 9220,
VECTOR, VECTOR_AC
9677, 9678
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2104
BI: 2nd acknowledge faults / 2nd acknowledge
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HUB, TB30, TM120,
Not for motor type: -
Scaling: -
Expert list: 1
TM15, TM150,
Min:
Max:
Factory setting:
TM15DI_DO, TM17,
-
-
0
TM31, TM54F_MA,
TM54F_SL
p2104[0...n]
BI: 2nd acknowledge faults / 2nd acknowledge
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2546, 8060
SERVO_AC, TM41,
P-Group: Messages
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1242
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p2105
BI: 3rd acknowledge faults / 3rd acknowledge
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HUB, TB30, TM120,
Not for motor type: -
Scaling: -
Expert list: 1
TM15, TM150,
Min:
Max:
Factory setting:
TM15DI_DO, TM17,
-
-
0
TM31, TM54F_MA,
TM54F_SL
p2105[0...n]
BI: 3rd acknowledge faults / 3rd acknowledge
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2546, 8060
SERVO_AC, TM41,
P-Group: Messages
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p2106
BI: External fault 1 / External fault 1
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HUB, TB30, TM120,
Not for motor type: -
Scaling: -
Expert list: 1
TM15, TM150,
Min:
Max:
Factory setting:
TM15DI_DO, TM17,
-
-
1
TM31, TM54F_MA,
TM54F_SL
p2106[0...n]
BI: External fault 1 / External fault 1
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2546
SERVO_AC, TM41,
P-Group: Messages
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p2107
BI: External fault 2 / External fault 2
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Messages
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HUB, TB30, TM120,
Not for motor type: -
Scaling: -
Expert list: 1
TM15, TM150,
Min:
Max:
Factory setting:
TM15DI_DO, TM17,
-
-
1
TM31, TM54F_MA,
TM54F_SL
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1243

 

 

 

 

 

 

 

Content      ..     16      17      18      19     ..