SINAMICS parameters
3.2 SINAMICS parameters
p1262[0...n]
Bypass dead time / Bypass t_dead
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 8
SERVO_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.000 [s]
20.000 [s]
1.000 [s]
p1262[0...n]
Bypass dead time / Bypass t_dead
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 2
VECTOR_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
20.000 [s]
1.000 [s]
p1263
Debypass delay time / Debypass t_del
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.000 [s]
300.000 [s]
1.000 [s]
p1263
Debypass delay time / Debypass t_del
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
300.000 [s]
1.000 [s]
p1264
Bypass delay time / Bypass t_del
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.000 [s]
300.000 [s]
1.000 [s]
p1264
Bypass delay time / Bypass t_del
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
300.000 [s]
1.000 [s]
Machine data and parameters
1038
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1265
Bypass velocity threshold / Bypass v_thr
SERVO (Lin, Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Lin,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
Tech_ctrl)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: REL, RESM
Scaling: p2000
Expert list: 0
Min:
Max:
Factory setting:
0.00 [m/min]
1300.00 [m/min]
60.00 [m/min]
p1265
Bypass speed threshold / Bypass n_thr
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: REL, RESM
Scaling: p2000
Expert list: 0
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
1480.00 [rpm]
p1265
Bypass speed threshold / Bypass n_thr
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL, RESM
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
1480.00 [rpm]
p1266
BI: Bypass control command / Bypass command
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
p1266
BI: Bypass control command / Bypass command
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (Tech_ctrl)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1267
Bypass changeover source configuration / Chgov_src config
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl)
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1039
SINAMICS parameters
3.2 SINAMICS parameters
p1267
Bypass changeover source configuration / Chgov_src config
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR_AC (Tech_ctrl)
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p1268
BI: Bypass feedback synchronization completed / FS sync compl
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
p1268
BI: Bypass feedback synchronization completed / FS sync compl
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (Tech_ctrl)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
3819.2
p1269[0...1]
BI: Bypass switch feedback signal / Bypass FS
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
p1269[0...1]
BI: Bypass switch feedback signal / Bypass FS
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (Tech_ctrl)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1270[0...n]
Flying restart configuration / FlyRest config
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 4
Data type: Unsigned16
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
Machine data and parameters
1040
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1271[0...n]
Flying restart maximum frequency for the inhibited direction / FlyRest f_max dir
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [Hz]
650 [Hz]
0 [Hz]
p1272
Simulation mode / Simulation mode
HLA, SERVO, SERVO_AC Can be changed: T
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
1
0
p1272
Simulation mode / Simulation mode
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1274[0...1]
Bypass switch monitoring time / Switch t_mon
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0 [ms]
5000 [ms]
1000 [ms]
p1274[0...1]
Bypass switch monitoring time / Switch t_mon
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
5000 [ms]
1000 [ms]
p1275
Motor holding brake control word / Brake STW
SERVO (Ext brake),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext brake),
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR (Ext brake),
P-Group: Functions
Unit group: -
Unit selection: -
VECTOR_AC (Ext brake)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1041
SINAMICS parameters
3.2 SINAMICS parameters
p1276
Motor holding brake standstill detection bypass / Brk standst bypass
SERVO (Ext brake),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext brake),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2704
VECTOR (Ext brake),
P-Group: Functions
Unit group: -
Unit selection: -
VECTOR_AC (Ext brake)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
300.000 [s]
300.000 [s]
p1277
Motor holding brake braking threshold delay exceeded / Del thr exc
SERVO (Ext brake),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext brake),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2707
VECTOR (Ext brake),
P-Group: Functions
Unit group: -
Unit selection: -
VECTOR_AC (Ext brake)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
300.000 [s]
0.000 [s]
p1278
Brake control diagnostics evaluation / Brake diagnostics
HLA
Can be changed: T, U
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
1
0
p1278
Brake control diagnostics evaluation / Brake diagnostics
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1279[0...3]
BI: Motor holding brake OR/AND logic operation / Brake OR AND
SERVO (Ext brake),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Ext brake),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2707
VECTOR (Ext brake),
P-Group: Functions
Unit group: -
Unit selection: -
VECTOR_AC (Ext brake)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1280[0...n]
Vdc controller or Vdc monitoring configuration (U/f) / Vdc_ctr config U/f
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: 6300, 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
1
Machine data and parameters
1042
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1280[0...n]
Vdc controller or Vdc monitoring configuration (U/f) / Vdc_ctr config U/f
VECTOR (F3E),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E)
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 6300, 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
0
0
p1281[0...n]
Vdc controller configuration / Vdc ctrl config
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
r1282
Vdc_max controller switch-in level (U/f) / Vdc_max on_level
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r1282
Vdc_max controller switch-in level (U/f) / Vdc_max on_level
VECTOR (F3E),
Can be changed: -
Calculated: -
Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p1283[0...n]
Vdc_max controller dynamic factor (U/f) / Vdc_max dyn_factor
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [%]
10000 [%]
100 [%]
p1283[0...n]
Vdc_max controller dynamic factor (U/f) / Vdc_max dyn_factor
VECTOR (F3E),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [%]
10000 [%]
100 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1043
SINAMICS parameters
3.2 SINAMICS parameters
p1284[0...n]
Vdc_max controller time threshold (U/f) / Vdc_max t_thr
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
300.000 [s]
4.000 [s]
p1284[0...n]
Vdc_max controller time threshold (U/f) / Vdc_max t_thr
VECTOR (F3E),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
300.000 [s]
4.000 [s]
p1285[0...n]
Vdc_min controller switch-in level (kinetic buffering) (U/f) / Vdc_min on_level
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
65 [%]
150 [%]
76 [%]
p1285[0...n]
Vdc_min controller switch-in level (kinetic buffering) (U/f) / Vdc_min on_level
VECTOR (F3E),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
65 [%]
150 [%]
76 [%]
r1286
Vdc_min controller switch-in level (kinetic buffering) (U/f) / Vdc_min on_level
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r1286
Vdc_min controller switch-in level (kinetic buffering) (U/f) / Vdc_min on_level
VECTOR (F3E),
Can be changed: -
Calculated: -
Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
Machine data and parameters
1044
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1287[0...n]
Vdc_min controller dynamic factor (kinetic buffering) (U/f) / Vdc_min dyn_factor
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [%]
10000 [%]
100 [%]
p1287[0...n]
Vdc_min controller dynamic factor (kinetic buffering) (U/f) / Vdc_min dyn_factor
VECTOR (F3E),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [%]
10000 [%]
100 [%]
p1288[0...n]
Vdc_max controller feedback coupling factor ramp-fct. gen. (U/f) / Vdc_max factor RFG
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
100.000
0.500
p1288[0...n]
Vdc_max controller feedback coupling factor ramp-fct. gen. (U/f) / Vdc_max factor RFG
VECTOR (F3E),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
100.000
0.500
p1289[0...n]
Vdc_max controller speed threshold (U/f) / Vdc_max n_thr
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
10.00 [rpm]
p1289[0...n]
Vdc_max controller speed threshold (U/f) / Vdc_max n_thr
VECTOR (F3E),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
10.00 [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1045
SINAMICS parameters
3.2 SINAMICS parameters
p1290[0...n]
Vdc controller proportional gain (U/f) / Vdc_ctrl Kp
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
1.00
p1290[0...n]
Vdc controller proportional gain (U/f) / Vdc_ctrl Kp
VECTOR (F3E),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
1.00
p1291[0...n]
Vdc controller integral time (U/f) / Vdc_ctrl Tn
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
10000 [ms]
40 [ms]
p1291[0...n]
Vdc controller integral time (U/f) / Vdc_ctrl Tn
VECTOR (F3E),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
10000 [ms]
40 [ms]
p1292[0...n]
Vdc controller rate time (U/f) / Vdc_ctrl Tv
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
10 [ms]
p1292[0...n]
Vdc controller rate time (U/f) / Vdc_ctrl Tv
VECTOR (F3E),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
10 [ms]
Machine data and parameters
1046
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1293[0...n]
Vdc min controller output limit (U/f) / Vdc_min outp_lim
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
600.00 [Hz]
10.00 [Hz]
p1293[0...n]
Vdc min controller output limit (U/f) / Vdc_min outp_lim
VECTOR (F3E),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6320
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
600.00 [Hz]
10.00 [Hz]
p1294
Vdc_max controller automatic detection ON signal level (U/f) / Vdc_max SenseOnLev
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1294
Vdc_max controller automatic detection ON signal level (U/f) / Vdc_max SenseOnLev
VECTOR (F3E),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1295[0...n]
Vdc_min controller time threshold (U/f) / Vdc_min t_thr
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
10000.000 [s]
0.000 [s]
p1295[0...n]
Vdc_min controller time threshold (U/f) / Vdc_min t_thr
VECTOR (F3E),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
10000.000 [s]
0.000 [s]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1047
SINAMICS parameters
3.2 SINAMICS parameters
p1296[0...n]
Vdc_min controller response (kinetic buffering) (U/f) / Vdc_min response
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1296[0...n]
Vdc_min controller response (kinetic buffering) (U/f) / Vdc_min response
VECTOR (F3E),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E)
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1297[0...n]
Vdc_min controller speed threshold (U/f) / Vdc_min n_thr
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Functions
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
50.00 [rpm]
p1297[0...n]
Vdc_min controller speed threshold (U/f) / Vdc_min n_thr
VECTOR (F3E),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Functions
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
50.00 [rpm]
r1298
CO: Vdc controller output (U/f) / Vdc_ctrl output
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6320
P-Group: Functions
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1298
CO: Vdc controller output (U/f) / Vdc_ctrl output
VECTOR (F3E),
Can be changed: -
Calculated: -
Access level: 8
VECTOR_AC (F3E)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6320
P-Group: Functions
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
Machine data and parameters
1048
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1300[0...n]
Open-loop/closed-loop control operating mode / Op/cl-lp ctrl_mode
SERVO, SERVO_AC
Can be changed: C2(1), T
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: 5060, 8012
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
20
23
21
p1300[0...n]
Open-loop/closed-loop control operating mode / Op/cl-lp ctrl_mode
SERVO (Lin),
Can be changed: C2(1), T
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: 5060, 8012
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
20
23
21
p1300[0...n]
Open-loop/closed-loop control operating mode / Op/cl-lp ctrl_mode
VECTOR, VECTOR_AC
Can be changed: C2(1), T
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: 6300, 6301,
8012
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
19
0
p1300[0...n]
Open-loop/closed-loop control operating mode / Op/cl-lp ctrl_mode
VECTOR (n/M),
Can be changed: C2(1), T
Calculated: -
Access level: 2
VECTOR_AC (n/M)
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: 6300, 6301,
8012
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
23
20
p1302[0...n]
U/f control configuration / U/f config
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: DDS, p0180 Function diagram: -
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 bin
r1305.0...15
CO/BO: U/f control status word 1 / U/f control ZSW1
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1049
SINAMICS parameters
3.2 SINAMICS parameters
p1310[0...n]
Starting current (voltage boost) permanent / I_start (Ua) perm
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6300, 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
250.0 [%]
50.0 [%]
p1311[0...n]
Starting current (voltage boost) when accelerating / I_start accel
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6300, 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
250.0 [%]
0.0 [%]
p1312[0...n]
Starting current (voltage boost) when starting / I_start start
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6300, 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
250.0 [%]
0.0 [%]
r1315
Voltage boost total / U_boost total
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
p1317[0...n]
U/f control activation / Uf act
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 5019, 5730
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1317[0...n]
U/f control activation / Uf act
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 5019, 5730
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
1050
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1318[0...n]
U/f control ramp-up/ramp-down time / Uf t_rmp-up_rmp-dn
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5300
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
999999.000 [s]
10.000 [s]
p1319[0...n]
U/f control voltage at zero frequency / Uf U at f=0 Hz
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5300
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Vrms]
100.0 [Vrms]
0.0 [Vrms]
p1320[0...n]
U/f control programmable characteristic frequency 1 / Uf char f1
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
3000.00 [Hz]
0.00 [Hz]
p1321[0...n]
U/f control programmable characteristic voltage 1 / Uf char U1
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Vrms]
10000.0 [Vrms]
0.0 [Vrms]
p1322[0...n]
U/f control programmable characteristic frequency 2 / Uf char f2
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
3000.00 [Hz]
0.00 [Hz]
p1323[0...n]
U/f control programmable characteristic voltage 2 / Uf char U2
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Vrms]
10000.0 [Vrms]
0.0 [Vrms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1051
SINAMICS parameters
3.2 SINAMICS parameters
p1324[0...n]
U/f control programmable characteristic frequency 3 / Uf char f3
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
3000.00 [Hz]
0.00 [Hz]
p1325[0...n]
U/f control programmable characteristic voltage 3 / Uf char U3
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Vrms]
10000.0 [Vrms]
0.0 [Vrms]
p1326[0...n]
U/f control characteristic frequency / Uf char f
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5300
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
10000.00 [Hz]
0.00 [Hz]
p1326[0...n]
U/f control programmable characteristic frequency 4 / Uf char f4
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
10000.00 [Hz]
0.00 [Hz]
p1327[0...n]
U/f control characteristic voltage / Uf char U
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5300
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Vrms]
10000.0 [Vrms]
0.0 [Vrms]
p1327[0...n]
U/f control programmable characteristic voltage 4 / Uf char U4
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Vrms]
10000.0 [Vrms]
0.0 [Vrms]
Machine data and parameters
1052
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1330[0...n]
CI: U/f control independent voltage setpoint / Uf U_set independ.
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1331[0...n]
Voltage limiting / U_lim
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6300
P-Group: -
Unit group: 5_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.00 [Vrms]
2000.00 [Vrms]
1000.00 [Vrms]
p1333[0...n]
U/f control FCC starting frequency / U/f FCC f_start
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
3000.00 [Hz]
0.00 [Hz]
p1334[0...n]
U/f control slip compensation starting frequency / Slip comp start
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6310
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
3000.00 [Hz]
0.00 [Hz]
p1335[0...n]
Slip compensation scaling / Slip comp scal
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6300, 6310
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
600.0 [%]
0.0 [%]
p1336[0...n]
Slip compensation limit value / Slip comp lim val
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6310
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
600.00 [%]
250.00 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1053
SINAMICS parameters
3.2 SINAMICS parameters
r1337
CO: Actual slip compensation / Slip comp act val
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6310
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL, RESM
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p1338[0...n]
U/f mode resonance damping gain / Uf Res_damp gain
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5300
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
1.00
p1338[0...n]
U/f mode resonance damping gain / Uf Res_damp gain
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6300, 6310
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
0.00
p1339[0...n]
U/f mode resonance damping filter time constant / Uf Res_damp Tc
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5300
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.00 [ms]
1000.00 [ms]
20.00 [ms]
p1339[0...n]
U/f mode resonance damping filter time constant / Uf Res_damp Tc
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6310
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.00 [ms]
1000.00 [ms]
20.00 [ms]
p1340[0...n]
I_max frequency controller proportional gain / I_max_ctrl Kp
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6300
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
0.500
0.000
Machine data and parameters
1054
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1341[0...n]
I_max frequency controller integral time / I_max_ctrl Tn
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6300
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
50.000 [s]
0.300 [s]
r1343
CO: I_max controller frequency output / I_max_ctrl f_outp
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6300
P-Group: V/f open-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1344
I_max controller voltage output / I_max_ctrl U_outp
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6300
P-Group: V/f open-loop control
Unit group: 5_1
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
p1345[0...n]
DC braking proportional gain / DCBRK Kp
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6300, 7017
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
100000.000
0.000
p1345[0...n]
I_max voltage controller proportional gain / I_max_U_ctrl Kp
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6300, 7017
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
100000.000
0.000
p1346[0...n]
DC braking integral time / DCBRK Tn
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6300, 7017
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [ms]
50.000 [ms]
0.030 [ms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1055
SINAMICS parameters
3.2 SINAMICS parameters
p1346[0...n]
I_max voltage controller integral time / I_max_U_ctrl Tn
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6300, 7017
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
50.000 [s]
0.030 [s]
r1348
CO: U/f control Eco factor actual value / Uf Eco fac ActV
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6300, 6301
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p1349[0...n]
U/f mode resonance damping maximum frequency / Uf res_damp f_max
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
3000.00 [Hz]
3000.00 [Hz]
p1349[0...n]
U/f mode resonance damping maximum frequency / Uf res_damp f_max
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6310
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
3000.00 [Hz]
0.00 [Hz]
p1350[0...n]
U/f control soft start / U/f soft start
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: 6300
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1351[0...n]
CO: Motor holding brake starting frequency / Brake f_start
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6310
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-300.00 [%]
300.00 [%]
0.00 [%]
Machine data and parameters
1056
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1356[0...n]
CI: U/f control angular setpoint / Uf ang setpoint
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: -
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2005
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1358[0...n]
Angular difference symmetrizing actual angle / Sym act angle
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
r1359
CO: Angular difference / Angular difference
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2005
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
p1360
Braking chopper braking resistor cold / Brk_chop R cold
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [ohm]
10.000 [ohm]
0.000 [ohm]
p1362[0...1]
Braking chopper activation threshold / Brk_chop thr
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [V]
1158 [V]
[0] 0 [V]
[1] 60 [V]
r1363
CO: Braking chopper output voltage / Brk_chop U_output
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 5_1
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1057
SINAMICS parameters
3.2 SINAMICS parameters
p1364
Braking chopper resistor asymmetry / Brk_chop R asym
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: V/f open-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
100.00 [%]
25.00 [%]
r1369[0]
CO: Phase current actual value filtered / I_ph ActV filt
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6300
P-Group: V/f open-loop control
Unit group: 6_5
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
p1380[0...n]
Operation without load voltage reduction factor / Op w/o load U_red
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
70 [%]
100 [%]
100 [%]
p1381[0...n]
U/f control modulation limit reduction / U/f mod_lim red
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated:
Access level: 3
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6723
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
40.0 [%]
0.0 [%]
p1382[0...n]
Flux setpoint saturation limit / Flux set sat_lim
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6723
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
100.0 [%]
130.0 [%]
100.0 [%]
p1400[0...n]
Closed-loop control configuration / Ctrl config
HLA
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 2
Data type: Unsigned32
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
Machine data and parameters
1058
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1400[0...n]
Speed control configuration / n_ctrl config
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: DDS, p0180
Function diagram: 5019, 5490
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0011 1010 0000 bin
p1400[0...n]
Velocity control configuration / v_ctrl config
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: Unsigned32
Dynamic index: DDS, p0180
Function diagram: 5019, 5490
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0011 1010 0000 bin
p1400[0...n]
Speed control configuration / n_ctrl config
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR_AC (n/M)
Data type: Unsigned32
Dynamic index: DDS, p0180
Function diagram: 6490
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 1000
0000 0010 0001 bin
p1401[0...n]
Flux control configuration / Flux ctrl config
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: 6491
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 1110 bin
p1402[0...n]
Closed-loop current control and motor model configuration / I_ctrl config
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0100 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1059
SINAMICS parameters
3.2 SINAMICS parameters
p1402[0...n]
Closed-loop current control and motor model configuration / I_ctrl config
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0100 bin
p1402[0...n]
Closed-loop current control and motor model configuration / I_ctrl config
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned16
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0001 bin
p1404[0...n]
Encoderless operation changeover velocity / Encoderl op v_chg
HLA
Can be changed: T
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5019, 5060
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
210000.00 [m/min]
210000.00 [m/min]
p1404[0...n]
Encoderless operation changeover speed / Encoderl op n_chg
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5019, 5060
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
210000.00 [rpm]
p1404[0...n]
Encoderless operation changeover velocity / Encoderl op v_chg
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5019, 5060
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
1000.00 [m/min]
p1404[0...n]
Encoderless operation changeover speed / Encoderl op n_chg
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5019, 5060
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
40000.00 [rpm]
Machine data and parameters
1060
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1405.0...15
CO/BO: Closed-loop control status word 1 / Control ZSW1
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 8
VECTOR_AC (n/M)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1406.8...12
CO/BO: Control word speed controller / STW n_ctrl
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2520
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1406.8...12
CO/BO: Control word velocity controller / STW v_ctrl
HLA, SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: -
Function diagram: 2520
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1406.4...15
CO/BO: Control word speed controller / STW n_ctrl
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned16
Dynamic index: -
Function diagram: 2520
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1407.0...20
CO/BO: Status word controller / ZSW ctrl
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1407.0...26
CO/BO: Status word speed controller / ZSW n_ctrl
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 2522
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1061
SINAMICS parameters
3.2 SINAMICS parameters
r1407.0...26
CO/BO: Status word velocity controller / ZSW v_ctrl
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32
Dynamic index: -
Function diagram: 2522
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1407.0...27
CO/BO: Status word speed controller / ZSW n_ctrl
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32
Dynamic index: -
Function diagram: 2522
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1408.0...9
CO/BO: Status word current controller / ZSW I_ctrl
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2530, 5040
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1408.0...15
CO/BO: Status word current controller / ZSW I_ctrl
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned16
Dynamic index: -
Function diagram: 2530
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1409[0...n]
Speed control extended configuration / n_ctrl ext config
SERVO, SERVO_AC
Can be changed: C1(3)
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p1409[0...n]
Velocity control extended configuration / v_ctrl ext config
SERVO (Lin),
Can be changed: C1(3)
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: Unsigned32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
Machine data and parameters
1062
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1409[0...n]
Speed control extended configuration / n_ctrl ext config
VECTOR (n/M),
Can be changed: C1(3), T
Calculated: -
Access level: 8
VECTOR_AC (n/M)
Data type: Unsigned32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0000 bin
p1412[0...n]
TM41 increm. encoder emulation, speed setpoint filter deadtime / n_set dead time
TM41
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 9674
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [ms]
1.000 [ms]
0.000 [ms]
p1413[0...n]
Velocity actual value filter activation / v_act_filt act
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p1413[0...n]
Speed actual value filter activation / n_act_filt act
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: 5040, 5042,
5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p1413[0...n]
Velocity actual value filter activation / v_act_filt act
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: 5040, 5042,
5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p1414[0...n]
Velocity setpoint filter activation / v_set_filt act
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1063
SINAMICS parameters
3.2 SINAMICS parameters
p1414[0...n]
Speed setpoint filter activation / n_set_filt act
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p1414[0...n]
Velocity setpoint filter activation / v_set_filt act
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p1414[0...n]
TM41 incr. encoder emulation speed setpoint filter activation / n_set_filt act
TM41
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: 9674
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p1415[0...n]
Velocity setpoint filter 1 type / v_set_filt 1 type
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p1415[0...n]
Speed setpoint filter 1 type / n_set_filt 1 type
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p1415[0...n]
Velocity setpoint filter 1 type / v_set_filt 1 type
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
Machine data and parameters
1064
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1416[0...n]
Velocity setpoint filter 1 time constant / v_set_filt 1 Tc
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
5000.00 [ms]
0.00 [ms]
p1416[0...n]
Speed setpoint filter 1 time constant / n_set_filt 1 Tc
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
5000.00 [ms]
0.00 [ms]
p1416[0...n]
Velocity setpoint filter 1 time constant / v_set_filt 1 Tc
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
5000.00 [ms]
0.00 [ms]
p1416[0...n]
Speed setpoint filter 1 time constant / n_set_filt 1 Tc
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6020, 6030
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
5000.00 [ms]
0.00 [ms]
p1417[0...n]
Velocity setpoint filter 1 denominator natural frequency / v_set_filt1 fn_den
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1417[0...n]
Speed setpoint filter 1 denominator natural frequency / n_set_filt1 fn_den
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1065
SINAMICS parameters
3.2 SINAMICS parameters
p1417[0...n]
Velocity setpoint filter 1 denominator natural frequency / v_set_filt1 fn_den
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1417[0...n]
Speed setpoint filter 1 denominator natural frequency / n_set_filt1 fn_den
VECTOR (J_estimator /
Can be changed: T, U
Calculated: -
Access level: 8
OBT), VECTOR_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
(J_estimator / OBT)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1417[0...n]
TM41 Speed setpoint filter 1 denominator natural frequency / n_set_filt1 fn_den
TM41
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 9674
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1418[0...n]
Velocity setpoint filter 1 denominator damping / v_set_filt 1 D_den
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001
10.000
0.700
p1418[0...n]
Speed setpoint filter 1 denominator damping / n_set_filt 1 D_den
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001
10.000
0.700
p1418[0...n]
Velocity setpoint filter 1 denominator damping / v_set_filt 1 D_den
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001
10.000
0.700
Machine data and parameters
1066
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1418[0...n]
TM41 Speed setpoint filter 1 denominator damping / n_set_filt 1 D_den
TM41
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 9674
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001
1.000
0.700
p1419[0...n]
Velocity setpoint filter 1 numerator natural frequency / v_set_filt1 fn_num
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1419[0...n]
Speed setpoint filter 1 numerator natural frequency / n_set_filt1 fn_num
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1419[0...n]
Velocity setpoint filter 1 numerator natural frequency / v_set_filt1 fn_num
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1419[0...n]
Speed setpoint filter 1 numerator natural frequency / n_set_filt1 fn_num
VECTOR (J_estimator /
Can be changed: T, U
Calculated: -
Access level: 8
OBT), VECTOR_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
(J_estimator / OBT)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1420[0...n]
Velocity setpoint filter 1 numerator damping / v_set_filt 1 D_num
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
10.000
0.700
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1067
SINAMICS parameters
3.2 SINAMICS parameters
p1420[0...n]
Speed setpoint filter 1 numerator damping / n_set_filt 1 D_num
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
10.000
0.700
p1420[0...n]
Velocity setpoint filter 1 numerator damping / v_set_filt 1 D_num
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
10.000
0.700
p1421[0...n]
Velocity setpoint filter 2 type / v_set_filt 2 type
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p1421[0...n]
Speed setpoint filter 2 type / n_set_filt 2 type
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p1421[0...n]
Velocity setpoint filter 2 type / v_set_filt 2 type
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p1422[0...n]
Velocity setpoint filter 2 time constant / v_set_filt 2 Tc
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
5000.00 [ms]
0.00 [ms]
Machine data and parameters
1068
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1422[0...n]
Speed setpoint filter 2 time constant / n_set_filt 2 Tc
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
5000.00 [ms]
0.00 [ms]
p1422[0...n]
Velocity setpoint filter 2 time constant / v_set_filt 2 Tc
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
5000.00 [ms]
0.00 [ms]
p1423[0...n]
Velocity setpoint filter 2 denominator natural frequency / v_set_filt2 fn_den
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1423[0...n]
Speed setpoint filter 2 denominator natural frequency / n_set_filt2 fn_den
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1423[0...n]
Velocity setpoint filter 2 denominator natural frequency / v_set_filt2 fn_den
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1424[0...n]
Velocity setpoint filter 2 denominator damping / v_set_filt 2 D_den
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001
10.000
0.700
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1069
SINAMICS parameters
3.2 SINAMICS parameters
p1424[0...n]
Speed setpoint filter 2 denominator damping / n_set_filt 2 D_den
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001
10.000
0.700
p1424[0...n]
Velocity setpoint filter 2 denominator damping / v_set_filt 2 D_den
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001
10.000
0.700
p1425[0...n]
Velocity setpoint filter 2 numerator natural frequency / v_set_filt2 fn_num
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1425[0...n]
Speed setpoint filter 2 numerator natural frequency / n_set_filt2 fn_num
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1425[0...n]
Velocity setpoint filter 2 numerator natural frequency / v_set_filt2 fn_num
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1426[0...n]
Velocity setpoint filter 2 numerator damping / v_set_filt 2 D_num
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
10.000
0.700
Machine data and parameters
1070
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1426[0...n]
Speed setpoint filter 2 numerator damping / n_set_filt 2 D_num
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
10.000
0.700
p1426[0...n]
Velocity setpoint filter 2 numerator damping / v_set_filt 2 D_num
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
10.000
0.700
p1427[0...n]
DSC symmetrizing time constant additive T_SYMM_ADD / DSC Tc_SYMM_ADD
SERVO (DSC spline,
Can be changed: T, U
Calculated: -
Access level: 3
Lin), SERVO_AC (DSC
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 3090
spline, Lin)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
1000.00 [ms]
0.00 [ms]
p1427[0...n]
DSC symmetrizing time constant additive T_SYMM_ADD / DSC Tc_SYMM_ADD
SERVO (DSC spline),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (DSC spline)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 3090
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
1000.00 [ms]
0.00 [ms]
p1428[0...n]
Velocity precontrol symmetrizing dead time / v_prectrSym t_dead
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5030, 5042,
5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0
3.0
0.0
p1428[0...n]
Speed precontrol symmetrizing dead time / n_prectrSym t_dead
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5030, 5042,
5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0
2.0
0.0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1071
SINAMICS parameters
3.2 SINAMICS parameters
p1428[0...n]
Velocity precontrol symmetrizing dead time / v_prectrSym t_dead
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5030, 5042,
5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0
2.0
0.0
p1428[0...n]
Speed precontrol symmetrizing dead time / n_prectrSym t_dead
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6031
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0
3.0
0.0
p1429[0...n]
Speed precontrol symmetrizing time constant / n_prectrl sym Tc
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, VECTOR (n/
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5030, 5042,
M), VECTOR_AC (n/M)
5210, 6031
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
10000.00 [ms]
0.00 [ms]
p1429[0...n]
Velocity precontrol symmetrizing time constant / v_prectrl sym Tc
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5030, 5042,
5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
10000.00 [ms]
0.00 [ms]
p1430[0...n]
CI: Velocity precontrol / v_prectrl
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 3001, 5019,
5030
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1072
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1430[0...n]
CI: Speed precontrol / n_prectrl
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3001, 5019,
5030
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1430[0...n]
CI: Velocity precontrol / v_prectrl
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3001, 5019,
5030
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1430[0...n]
CI: Speed precontrol / n_prectrl
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 6020, 6031
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r1431
CO: Speed precontrol to motor model / n_prectrl MotMod
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6030
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1432[0...1]
CO: Speed precontrol / n_prectrl
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5020, 5030
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1432[0...1]
CO: Velocity precontrol / v_precontrol
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5020, 5030
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1073
SINAMICS parameters
3.2 SINAMICS parameters
r1432[0...1]
CO: Speed precontrol / n_prectrl
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6031
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1433[0...n]
Velocity controller reference model natural frequency / v_ctrl RefMod fn
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Hz]
8000.0 [Hz]
0.0 [Hz]
p1433[0...n]
Speed controller reference model natural frequency / n_ctrl RefMod fn
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5030
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Hz]
8000.0 [Hz]
0.0 [Hz]
p1433[0...n]
Velocity controller reference model natural frequency / v_ctrl RefMod fn
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5030
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Hz]
8000.0 [Hz]
0.0 [Hz]
p1433[0...n]
Speed controller reference model natural frequency / n_ctrl RefMod fn
VECTOR (J_estimator /
Can be changed: T, U
Calculated: -
Access level: 3
OBT, J_estimator / OBT,
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6031
n/M, n/M), VECTOR_AC
P-Group: Closed-loop control
Unit group: -
Unit selection: -
(J_estimator / OBT,
J_estimator / OBT, n/M,
Not for motor type: REL
Scaling: -
Expert list: 1
n/M)
Min:
Max:
Factory setting:
0.0 [Hz]
8000.0 [Hz]
0.0 [Hz]
p1434[0...n]
Velocity controller reference model damping / v_ctrl RefMod D
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
5.000
1.000
Machine data and parameters
1074
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1434[0...n]
Speed controller reference model damping / n_ctrl RefMod D
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5030, 6031
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
5.000
1.000
p1434[0...n]
Velocity controller reference model damping / v_ctrl RefMod D
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5030, 6031
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
5.000
1.000
p1434[0...n]
Speed controller reference model damping / n_ctrl RefMod D
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5030, 6031
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
5.000
1.000
p1435[0...n]
Speed controller reference model dead time / n_ctrRefMod t_dead
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5030, 6031
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
2.00
0.00
p1435[0...n]
Velocity controller reference model dead time / v_ctrRefMod t_dead
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5030, 6031
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
2.00
0.00
p1435[0...n]
Speed controller reference model dead time / n_ctrRefMod t_dead
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5030, 6031
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
3.00
0.00
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1075
SINAMICS parameters
3.2 SINAMICS parameters
r1436
CO: Velocity controller reference model velocity_setpoint output / RefMod v_set outp
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4965
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1436
CO: Speed controller reference model speed setpoint output / RefMod n_set outp
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5030, 6031
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1436
CO: Velocity controller reference model velocity_setpoint output / RefMod v_set outp
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5030, 6031
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1436
CO: Speed controller reference model speed setpoint output / RefMod n_set outp
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5030, 6031
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1437[0...n]
CI: Speed controller reference model I component input / n_ctrRefMod I_comp
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 6031
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
1436[0]
r1438
CO: Velocity controller velocity setpoint / v_ctrl v_set
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4965
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
Machine data and parameters
1076
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1438
CO: Speed controller speed setpoint / n_ctrl n_set
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 5019,
5030, 5042, 5210
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1438
CO: Velocity controller velocity setpoint / v_ctrl v_set
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 5019,
5030, 5042, 5210
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1438
CO: Speed controller speed setpoint / n_ctrl n_set
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 5019,
5030, 5042, 5210, 6020, 6031
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1439
Speed setpoint I component / n_set I_comp
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR (n/M),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5030, 5040,
VECTOR_AC (n/M)
6031
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1439
Velocity setpoint I component / v_set I_comp
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5030, 5040,
6031
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1077
SINAMICS parameters
3.2 SINAMICS parameters
p1440[0...n]
CI: Speed controller speed actual value input / n_ctrl n_act
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 6040
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
63[0]
p1441[0...n]
Actual velocity smoothing time / v_act t_smth
HLA
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
50.00 [ms]
0.00 [ms]
p1441[0...n]
Actual speed smoothing time / n_act t_smth
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4710, 4715
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
50.00 [ms]
0.00 [ms]
p1441[0...n]
Actual velocity smoothing time / v_act t_smth
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4710, 4715
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
50.00 [ms]
0.00 [ms]
p1441[0...n]
Actual speed smoothing time / n_act t_smth
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4710, 4715
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
1000.00 [ms]
0.00 [ms]
p1442[0...n]
Speed controller speed actual value smoothing time / n_ctr n_act t_smth
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 2
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6020, 6040
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
32000.00 [ms]
4.00 [ms]
Machine data and parameters
1078
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1443
CO: Speed controller speed actual value at actual value input / n_ctrl n_act inp
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6040
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1444
Velocity controller velocity setpoint static / v_ctrl v_set stat
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1444
Speed controller speed setpoint steady-state (static) / n_ctrl n_set stat
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR (n/M),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5030
VECTOR_AC (n/M)
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1444
Velocity controller velocity setpoint total / v_ctrl v_set stat
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5030
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1445
CO: Actual velocity smoothed / v_act smth
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4965
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1445
CO: Actual speed smoothed / n_act smth
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040, 5210
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1079
SINAMICS parameters
3.2 SINAMICS parameters
r1445
CO: Actual velocity smoothed / v_act smth
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040, 5210
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1445
CO: Actual speed smoothed / n_act smth
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6040
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1446[0...n]
Velocity actual value filter type / v_act_filt type
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
2
2
p1446[0...n]
Speed actual value filter type / n_act_filt type
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 5040, 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
2
2
p1446[0...n]
Velocity actual value filter type / v_act_filt type
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 5040, 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
2
2
p1447[0...n]
Velocity actual value filter denominator natural frequency / v_act_filt fn_den
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
Machine data and parameters
1080
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1447[0...n]
Speed actual value filter denominator natural frequency / n_act_filt fn_den
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5040, 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1447[0...n]
Velocity actual value filter denominator natural frequency / v_act_filt fn_den
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5040, 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1448[0...n]
Velocity actual value filter denominator damping / v_act_filt D_den
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001
10.000
0.700
p1448[0...n]
Speed actual value filter denominator damping / n_act_filt D_den
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5040, 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001
10.000
0.700
p1448[0...n]
Velocity actual value filter denominator damping / v_act_filt D_den
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5040, 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001
10.000
0.700
p1449[0...n]
Velocity actual value filter numerator natural frequency / v_act_filt fn_num
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1081
SINAMICS parameters
3.2 SINAMICS parameters
p1449[0...n]
Speed actual value filter numerator natural frequency / n_act_filt fn_num
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5040, 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1449[0...n]
Velocity actual value filter numerator natural frequency / v_act_filt fn_num
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5040, 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p1450[0...n]
Velocity actual value filter numerator damping / v_act_filt D_num
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
10.000
0.700
p1450[0...n]
Speed actual value filter numerator damping / n_act_filt D_num
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5040, 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
10.000
0.700
p1450[0...n]
Velocity actual value filter numerator damping / v_act_filt D_num
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5040, 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
10.000
0.700
p1451[0...n]
Speed actual value smoothing time sensorless / n_ActV t_smth sl
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
0 [ms]
Machine data and parameters
1082
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1451[0...n]
Velocity actual value smoothing time sensorless / v_ActV t_smth sl
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
0 [ms]
p1451[0...n]
Motor model speed actual value smoothing time sensorless / MotMod n_act t_sm
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
4 [ms]
p1452[0...n]
Speed controller speed actual value smoothing time (sensorless) / n_C n_ActV t_s sl
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6020, 6040
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
32000.00 [ms]
10.00 [ms]
r1454
CO: Velocity controller system deviation I component / v_ctrl SysDev Tn
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1454
CO: Speed controller system deviation I component / n_ctrl SysDev Tn
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1454
CO: Velocity controller system deviation I component / v_ctrl SysDev Tn
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1083
SINAMICS parameters
3.2 SINAMICS parameters
r1454
CO: Speed controller system deviation I component / n_ctrl SysDev Tn
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6040
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1455[0...n]
CI: Speed controller P gain adaptation signal / n_ctrl adpt_sig Kp
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 5050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1455[0...n]
CI: Velocity controller P gain adaptation signal / v_ctrl adpt_sig Kp
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 5050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1455[0...n]
CI: Speed controller P gain adaptation signal / n_ctrl adpt_sig Kp
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 6050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1456[0...n]
Speed controller P gain adaptation lower starting point / n_ctrl adpt Kp low
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
400.00 [%]
0.00 [%]
p1456[0...n]
Velocity controller P gain adaptation lower starting point / v_ctrl adpt Kp low
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
400.00 [%]
0.00 [%]
Machine data and parameters
1084
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1456[0...n]
Speed controller P gain adaptation lower starting point / n_ctrl adpt Kp low
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
400.00 [%]
0.00 [%]
p1457[0...n]
Speed controller P gain adaptation upper starting point / n_ctrl adpt Kp up
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
400.00 [%]
0.00 [%]
p1457[0...n]
Velocity controller P gain adaptation upper starting point / v_ctrl adpt KpUp
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
400.00 [%]
0.00 [%]
p1457[0...n]
Speed controller P gain adaptation upper starting point / n_ctrl adpt Kp up
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
400.00 [%]
0.00 [%]
p1458[0...n]
Adaptation factor lower / Adapt_factor lower
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
200000.0 [%]
100.0 [%]
p1458[0...n]
Adaptation factor lower / Adapt_factor lower
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
200000.0 [%]
100.0 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1085
SINAMICS parameters
3.2 SINAMICS parameters
p1459[0...n]
Adaptation factor upper / Adapt_factor upper
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
200000.0 [%]
100.0 [%]
p1459[0...n]
Adaptation factor upper / Adapt_factor upper
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
200000.0 [%]
100.0 [%]
p1460[0...n]
Velocity controller P gain A / v_ctrl Kp A
HLA
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100.000 [%]
1000.000 [%]
0.000 [%]
p1460[0...n]
Speed controller P gain adaptation speed lower / n_ctrl Kp n lower
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5040, 5042
P-Group: Closed-loop control
Unit group: 17_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0000 [Nms/rad]
500000000.0000 [Nms/rad]
0.3000 [Nms/rad]
p1460[0...n]
Velocity controller P gain adaptation velocity lower / v_ctrl Kp n lower
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5040, 5042
P-Group: Closed-loop control
Unit group: 24_2
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0000 [Ns/m]
500000000.0000 [Ns/m]
10.0000 [Ns/m]
p1460[0...n]
Speed controller P gain adaptation speed lower / n_ctrl Kp n lower
VECTOR (J_estimator /
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
OBT, J_estimator / OBT,
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6020, 6040
n/M, n/M), VECTOR_AC
P-Group: Closed-loop control
Unit group: -
Unit selection: -
(J_estimator / OBT,
J_estimator / OBT, n/M,
Not for motor type: REL
Scaling: -
Expert list: 1
n/M)
Min:
Max:
Factory setting:
0.0000
999999.0000
0.3000
Machine data and parameters
1086
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1461[0...n]
Velocity controller P gain / v_ctrl Kp
HLA
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100.0 [%]
1000.0 [%]
0.0 [%]
p1461[0...n]
Speed controller Kp adaptation speed upper scaling / n_ctr Kp n up scal
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
200000.0 [%]
100.0 [%]
p1461[0...n]
Velocity controller Kp adaptation velocity upper scaling / v_ctr Kp n up scal
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
200000.0 [%]
100.0 [%]
p1461[0...n]
Speed controller Kp adaptation speed upper scaling / n_ctr Kp n up scal
VECTOR (J_estimator /
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
OBT, J_estimator / OBT,
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6050
n/M, n/M), VECTOR_AC
P-Group: Closed-loop control
Unit group: -
Unit selection: -
(J_estimator / OBT,
J_estimator / OBT, n/M,
Not for motor type: REL
Scaling: -
Expert list: 1
n/M)
Min:
Max:
Factory setting:
0.0 [%]
200000.0 [%]
100.0 [%]
p1462[0...n]
Velocity controller P gain B / v_ctrl Kp B
HLA
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100.00 [%]
1000.00 [%]
0.00 [%]
p1462[0...n]
Speed controller integral time adaptation speed lower / n_ctrl Tn n lower
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5040, 5042,
6020, 6040
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
100000.00 [ms]
20.00 [ms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1087
SINAMICS parameters
3.2 SINAMICS parameters
p1462[0...n]
Velocity contr. integral act. time adaptation velocity lower / v_ctrl Tn n lower
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5040, 5042
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
100000.00 [ms]
20.00 [ms]
p1462[0...n]
Speed controller integral time adaptation speed lower / n_ctrl Tn n lower
VECTOR (J_estimator /
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
OBT, J_estimator / OBT,
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5040, 5042,
n/M, n/M), VECTOR_AC
6020, 6040
(J_estimator / OBT,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
J_estimator / OBT, n/M,
n/M)
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
100000.00 [ms]
20.00 [ms]
p1463[0...n]
Velocity controller integral time / v_ctrl Tn
HLA
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
2000.0 [ms]
0.0 [ms]
p1463[0...n]
Speed controller Tn adaptation speed upper scaling / n_ctr Tn n up scal
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
200000.0 [%]
100.0 [%]
p1463[0...n]
Velocity controller Tn adaptation velocity upper scaling / v_ctr Tn n up scal
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
200000.0 [%]
100.0 [%]
p1463[0...n]
Speed controller Tn adaptation speed upper scaling / n_ctr Tn n up scal
VECTOR (J_estimator /
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
OBT, J_estimator / OBT,
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6050
n/M, n/M), VECTOR_AC
P-Group: Closed-loop control
Unit group: -
Unit selection: -
(J_estimator / OBT,
J_estimator / OBT, n/M,
Not for motor type: REL
Scaling: -
Expert list: 1
n/M)
Min:
Max:
Factory setting:
0.0 [%]
200000.0 [%]
100.0 [%]
Machine data and parameters
1088
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1464[0...n]
Velocity controller D component smoothing time constant / v_ctrl D comp Tc
HLA
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.25 [ms]
100.00 [ms]
0.25 [ms]
p1464[0...n]
Speed controller adaptation speed lower / n_ctrl n lower
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 5050
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
0.00 [rpm]
p1464[0...n]
Velocity controller adaptation velocity lower / v_ctrl n lower
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 5050
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
0.00 [m/min]
p1464[0...n]
Speed controller adaptation speed lower / n_ctrl n lower
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6050
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
0.00 [rpm]
p1465[0...n]
Velocity controller derivative-action time A / v_ctrl Tv A
HLA
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [ms]
1000.00 [ms]
0.00 [ms]
p1465[0...n]
Speed controller adaptation speed upper / n_ctrl n upper
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 5050
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
210000.00 [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1089
SINAMICS parameters
3.2 SINAMICS parameters
p1465[0...n]
Velocity controller adaptation velocity upper / v_ctrl n upper
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 5050
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
1000.00 [m/min]
p1465[0...n]
Speed controller adaptation speed upper / n_ctrl n upper
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6050
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
210000.00 [rpm]
p1466[0...n]
Velocity controller derivative-action time / v_ctrl Tv
HLA
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [ms]
1000.00 [ms]
0.00 [ms]
p1466[0...n]
CI: Speed controller P gain scaling / n_ctrl Kp scal
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 5050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1466[0...n]
CI: Velocity controller P gain scaling / v_ctrl Kp scal
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 5050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1466[0...n]
CI: Speed controller P gain scaling / n_ctrl Kp scal
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 6050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
1090
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1467[0...n]
Velocity controller derivative-action time B / v_ctrl Tv B
HLA
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [ms]
1000.00 [ms]
0.00 [ms]
r1468
Velocity controller P gain effective / v_ctrl Kp eff
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r1468
Speed controller P gain effective / n_ctrl Kp eff
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040, 5042,
5210
P-Group: Closed-loop control
Unit group: 17_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Nms/rad]
- [Nms/rad]
- [Nms/rad]
r1468
Velocity controller P gain effective / v_ctrl Kp eff
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040, 5042,
5210
P-Group: Closed-loop control
Unit group: 24_2
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Ns/m]
- [Ns/m]
- [Ns/m]
r1468
CO: Speed controller P gain effective / n_ctrl Kp eff
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6040
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1469
Velocity controller derivative-action time active / v_ctrl Tv act
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1091
SINAMICS parameters
3.2 SINAMICS parameters
r1469
Speed controller integral time effective / n_ctrl Tn eff
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR (n/M),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040, 5042,
VECTOR_AC (n/M)
6040
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
r1469
Velocity controller integral time effective / v_ctrl Tn eff
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040, 5042
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
p1470[0...n]
Speed controller encoderless operation P gain / n_ctrl SL Kp
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5210
P-Group: Closed-loop control
Unit group: 17_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [Nms/rad]
999999.00000 [Nms/rad]
0.30000 [Nms/rad]
p1470[0...n]
Velocity controller encoderless operation P gain / v_ctrl SLVC Kp
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5210
P-Group: Closed-loop control
Unit group: 24_2
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [Ns/m]
999999.00000 [Ns/m]
10.00000 [Ns/m]
p1470[0...n]
Speed controller encoderless operation P gain / n_ctrl SL Kp
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6040, 6050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000
999999.00000
0.30000
p1472[0...n]
Speed controller encoderless operation integral time / n_ctrl SL Tn
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
100000.0 [ms]
20.0 [ms]
Machine data and parameters
1092
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1472[0...n]
Velocity controller encoderless operation integral time / v_ctrl SLVC Tn
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
100000.0 [ms]
20.0 [ms]
p1472[0...n]
Speed controller encoderless operation integral time / n_ctrl SL Tn
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 2
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6040, 6050
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
100000.0 [ms]
20.0 [ms]
p1475[0...n]
Velocity controller loop gain / v_ctrl loop_gain
HLA
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [mm/Vmin]
20000.0 [mm/Vmin]
0.0 [mm/Vmin]
p1475[0...n]
CI: Speed controller torque setting value for motor holding brake / n_ctrl M_sv MHB
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 6040
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1476[0...n]
BI: Velocity controller hold integrator / v_ctrl integ stop
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1476[0...n]
BI: Speed controller hold integrator / n_ctrl integ stop
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 3
VECTOR (n/M),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2520, 5040,
VECTOR_AC (n/M)
5042, 5210, 6040
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1093
SINAMICS parameters
3.2 SINAMICS parameters
p1476[0...n]
BI: Velocity controller hold integrator / v_ctrl integ stop
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2520, 5040,
5042, 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1477[0...n]
BI: Velocity controller set integrator value / v_ctrl integ set
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1477[0...n]
BI: Speed controller set integrator value / n_ctrl integ set
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 3
VECTOR (n/M),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2520, 5040,
VECTOR_AC (n/M)
5042, 5210, 6040
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1477[0...n]
BI: Velocity controller set integrator value / v_ctrl integ set
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2520, 5040,
5042, 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1478[0...n]
CI: Velocity controller integrator value / v_ctr integ_setVal
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1094
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1478[0...n]
CI: Speed controller integrator setting value / n_ctr integ_setVal
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 5040, 5042,
5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1478[0...n]
CI: Velocity controller integrator value / v_ctr integ_setVal
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 5040, 5042,
5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1478[0...n]
CI: Speed controller integrator setting value / n_ctr integ_setVal
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 6040
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1479[0...n]
CI: Speed controller integrator setting value scaling / n_ctrl I_val scal
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 6040
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
r1480
CO: Velocity controller PID output / v_ctrl PID outp
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1095
SINAMICS parameters
3.2 SINAMICS parameters
r1480
CO: Speed controller PI torque output / n_ctrl PI-M_outp
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR (n/M),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5019, 5040,
VECTOR_AC (n/M)
5042, 5060, 5210, 6060
P-Group: Closed-loop control
Unit group: 7_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [Nm]
- [Nm]
- [Nm]
r1480
CO: Velocity controller PI force output / v_ctrl PI-F_outp
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5019, 5040,
5042, 5060, 5210
P-Group: Closed-loop control
Unit group: 8_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [N]
- [N]
- [N]
r1481
CO: Velocity controller P component output / v_ctrl P outp
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r1481
CO: Speed controller P torque output / n_ctrl P-M_outp
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR (n/M),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040, 5042,
VECTOR_AC (n/M)
5210, 6040
P-Group: Closed-loop control
Unit group: 7_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [Nm]
- [Nm]
- [Nm]
r1481
CO: Velocity controller P force output / v_ctrl P-F_outp
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040, 5042,
5210
P-Group: Closed-loop control
Unit group: 8_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [N]
- [N]
- [N]
Machine data and parameters
1096
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1482
CO: Velocity controller I component output / v_ctrl I outp
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r1482
CO: Speed controller I torque output / n_ctrl I-M_outp
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR (n/M),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040, 5042,
VECTOR_AC (n/M)
5210, 6030, 6040
P-Group: Closed-loop control
Unit group: 7_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [Nm]
- [Nm]
- [Nm]
r1482
CO: Velocity controller I force output / v_ctrl I-F_outp
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040, 5042,
5210
P-Group: Closed-loop control
Unit group: 8_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [N]
- [N]
- [N]
r1483
CO: Velocity controller D component output / v_ctrl D outp
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r1484
CO: Speed controller Kp adaptation as percentage / n_ctrl Kp adpt %
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040, 5042,
5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1097
SINAMICS parameters
3.2 SINAMICS parameters
r1484
CO: Velocity controller Kp adaptation as percentage / v_ctrl Kp adpt %
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040, 5042,
5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p1486[0...n]
CI: Droop compensation torque / Droop M_comp
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 6030
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1487[0...n]
Droop compensation torque scaling / Droop M_comp scal
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6030
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-2000.0 [%]
2000.0 [%]
100.0 [%]
p1488[0...n]
Droop input source / Droop input source
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 6030
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
p1489[0...n]
Droop feedback scaling / Droop scal
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6030
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
0.500
0.050
r1490
CO: Droop feedback speed reduction / Droop n_reduction
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6030
P-Group: Closed-loop control
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
Machine data and parameters
1098
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1492[0...n]
BI: Droop feedback enable / Droop enable
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2520, 6030
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r1493
CO: Moment of inertia total / M_inert total
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5042, 5210
P-Group: Closed-loop control
Unit group: 25_1
Unit selection: p0100
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kgm²]
- [kgm²]
- [kgm²]
r1493
CO: Total mass / Total mass
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5042, 5210
P-Group: Closed-loop control
Unit group: 27_1
Unit selection: p0100
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kg]
- [kg]
- [kg]
r1493
CO: Moment of inertia total, scaled / M_inert tot scal
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6031
P-Group: Closed-loop control
Unit group: 25_1
Unit selection: p0100
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kgm²]
- [kgm²]
- [kgm²]
p1494[0...n]
Velocity controller integrator feedback time constant / v_ctr integ_fdbkTc
HLA
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 4965
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
1000.00 [ms]
0.00 [ms]
p1494[0...n]
Speed controller integrator feedback time constant / n_ctr integ_fdbkTc
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5040, 5042,
5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
1000.00 [ms]
0.00 [ms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1099
SINAMICS parameters
3.2 SINAMICS parameters
p1494[0...n]
Velocity controller integrator feedback time constant / v_ctr integ_fdbkTc
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 5040, 5042,
5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
1000.00 [ms]
0.00 [ms]
p1495[0...n]
Integrator feedback velocity threshold / Integ_fdbk v_thr
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Closed-loop control
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [m/min]
120000.000 [m/min]
0.010 [m/min]
p1495[0...n]
CI: Acceleration precontrol / a_prectrl
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 6031
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2007
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1496[0...n]
Acceleration precontrol scaling / a_prectrl scal
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6020, 6031
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
10000.0 [%]
0.0 [%]
p1497[0...n]
CI: Moment of inertia scaling signal source / M_inert scal s_s
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 5042, 5210,
6030, 6031
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1497[0...n]
CI: Mass scaling signal source / Mass scal s_s
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 5042, 5210
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
1100
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1497[0...n]
CI: Moment of inertia scaling signal source / M_inert scal s_s
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 5042, 5210,
6030, 6031
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1498[0...n]
Load mass / Load mass
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Closed-loop control
Unit group: 27_1
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [kg]
100000.00000 [kg]
0.00000 [kg]
p1498[0...n]
Load moment of inertia / Load m_inert
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 5042, 5210
P-Group: Closed-loop control
Unit group: 25_1
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kgm²]
- [kgm²]
- [kgm²]
p1498[0...n]
Load mass / Load mass
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 5042, 5210
P-Group: Closed-loop control
Unit group: 27_1
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kg]
- [kg]
- [kg]
p1498[0...n]
Load moment of inertia / Load m_inert
VECTOR (J_estimator /
Can be changed: T, U
Calculated: -
Access level: 3
OBT, J_estimator / OBT,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6031
n/M, n/M), VECTOR_AC
P-Group: Closed-loop control
Unit group: 25_1
Unit selection: p0100
(J_estimator / OBT,
J_estimator / OBT, n/M,
Not for motor type: -
Scaling: -
Expert list: 1
n/M)
Min:
Max:
Factory setting:
0.00000 [kgm²]
100000.00000 [kgm²]
0.00000 [kgm²]
p1499[0...n]
Accelerating for torque control scaling / a for M_ctrl scal
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6030
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
400.0 [%]
100.0 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1101
SINAMICS parameters
3.2 SINAMICS parameters
p1500[0...n]
Macro Connector Inputs (CI) for torque setpoints / Macro CI M_set
SERVO, SERVO_AC,
Can be changed: C2(1), T
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: Unsigned32
Dynamic index: CDS, p0170 Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
999999
0
p1500[0...n]
Macro Connector Inputs (CI) for force setpoints / Macro CI F_set
HLA, SERVO (Lin),
Can be changed: C2(1), T
Calculated: -
Access level: 1
SERVO_AC (Lin)
Data type: Unsigned32
Dynamic index: CDS, p0170 Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
999999
0
p1500[0...n]
Macro Connector Inputs (CI) for torque setpoints / Macro CI M_set
A_INF, B_INF, R_INF,
Can be changed: C2(1), T
Calculated: -
Access level: 8
S_INF
Data type: Unsigned32
Dynamic index: CDS, p0170 Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
999999
0
p1501[0...n]
BI: Change over between closed-loop speed/torque control / Chgov n/M_ctrl
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR (n/M),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2520, 6020
VECTOR_AC (n/M)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1501[0...n]
BI: Change over velocity/force control / Chgov n/F_ctrl
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2520, 6020
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1502[0...n]
BI: Freeze moment of inertia estimator / J_estimator freeze
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1102
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1502[0...n]
BI: Freeze moment of inertia estimator / J_estimator freeze
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1503[0...n]
CI: Torque setpoint / M_set
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 6020, 6060
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1505
CI: Force actual value signal source / F_act s_s
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1506
Force actual value reference value for 100% for p1505 / F_act ref 100%
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Nm]
20000000.0 [Nm]
0.0 [Nm]
r1508
CO: Torque setpoint before supplementary torque / M_set bef M_suppl
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 2
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6030, 6060,
6722
P-Group: Closed-loop control
Unit group: 7_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [Nm]
- [Nm]
- [Nm]
r1509
CO: Torque setpoint before torque limiting / M_set before M_lim
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5019, 5060,
5610
P-Group: Closed-loop control
Unit group: 7_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [Nm]
- [Nm]
- [Nm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1103
SINAMICS parameters
3.2 SINAMICS parameters
r1509
CO: Force setpoint before force limiting / F_set before F_lim
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5019, 5060,
5610
P-Group: Closed-loop control
Unit group: 8_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [N]
- [N]
- [N]
p1511[0...n]
CI: Force setpoint / F_set
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 4970
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1511[0...n]
CI: Supplementary torque 1 / M_suppl 1
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 5060
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1511[0...n]
CI: Supplementary force 1 / F_suppl 1
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 5060
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1511[0...n]
CI: Supplementary torque 1 / M_suppl 1
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 6020, 6060
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1512[0...n]
CI: Force setpoint scaling / F_set scal
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 4970
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1104
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1512[0...n]
CI: Supplementary torque 1 scaling / M_suppl 1 scal
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 3
VECTOR (n/M),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 5060, 6060
VECTOR_AC (n/M)
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1512[0...n]
CI: Supplementary force 1 scaling / F_suppl 1 scal
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 5060, 6060
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1513[0...n]
CI: Supplementary torque 2 / M_suppl 2
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 5060
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1513[0...n]
CI: Supplementary force 2 / F_suppl 2
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 5060
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1513[0...n]
CI: Supplementary torque 2 / M_suppl 2
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 6020, 6060
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1514[0...n]
Supplementary torque 2 scaling / M_suppl 2 scal
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6020, 6060
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-2000.0 [%]
2000.0 [%]
100.0 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1105
|