SINUMERIK 840D sl. Service - Configuring Commissioning. Manual (2011-2020) - page 15

 

  Index      Manuals     SINUMERIK 840D sl. Service - Configuring Commissioning. Manual (2011-2020)

 

Search            copyright infringement  

 

   

 

   

 

Content      ..     13      14      15      16     ..

 

 

 

SINUMERIK 840D sl. Service - Configuring Commissioning. Manual (2011-2020) - page 15

 

 

SINAMICS parameters
3.2 SINAMICS parameters
p0874
BI: Smart/ Basic Line Module operation / SLM/BLM operation
A_INF, R_INF
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 8732, 8832
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
p0874
BI: Smart/ Basic Line Module operation / SLM/BLM operation
B_INF, S_INF
Can be changed: T
Calculated: -
Access level: 2
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 8732, 8832
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r0887.0...13
BO: ESR status word / ESR ZSW
HLA (ESR), SERVO
Can be changed: -
Calculated: -
Access level: 2
(ESR), SERVO_AC (ESR)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0888
ESR configuration / ESR configuration
HLA (ESR), SERVO
Can be changed: T, U
Calculated: -
Access level: 2
(ESR), SERVO_AC (ESR)
Data type: Integer16
Dynamic index: -
Function diagram: 3082
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4
0
p0889
BI: ESR response enable / Response enab
HLA (ESR), SERVO
Can be changed: T, U
Calculated: -
Access level: 2
(ESR), SERVO_AC (ESR)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3082
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
2090.9
Machine data and parameters
968
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0890[0...4]
BI: ESR trigger / ESR trigger
HLA (ESR), SERVO
Can be changed: T, U
Calculated: -
Access level: 2
(ESR), SERVO_AC (ESR)
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 3082
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 2090.2
[1] 9721.15
[2] 9723.1
[3] 9723.2
[4] 0
p0891
ESR OFF ramp / ESR OFF ramp
HLA (ESR), SERVO
Can be changed: T, U
Calculated: -
Access level: 2
(ESR), SERVO_AC (ESR)
Data type: Integer16
Dynamic index: -
Function diagram: 3082
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0892
ESR timer / ESR timer
HLA (ESR), SERVO
Can be changed: T, U
Calculated: -
Access level: 2
(ESR), SERVO_AC (ESR)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [s]
20.00 [s]
0.50 [s]
p0893
ESR velocity / ESR velocity
HLA (ESR), SERVO (ESR,
Can be changed: T, U
Calculated: -
Access level: 2
Lin), SERVO_AC (ESR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3082
Lin)
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-340.28235E36 [m/min]
340.28235E36 [m/min]
0 [m/min]
p0893
ESR speed / ESR speed
SERVO (ESR),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (ESR)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3082
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-340.28235E36 [rpm]
340.28235E36 [rpm]
0 [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
969
SINAMICS parameters
3.2 SINAMICS parameters
p0894
Parking pre-setting / Parking pre-set
ENC, HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p0895[0...n]
BI: Activate/deactivate power unit components / PU_comp act/deact
A_INF, B_INF, HLA,
Can be changed: T
Calculated: -
Access level: 1
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Displays, signals
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
r0896.0
BO: Parking axis, status word / Parking axis, ZSW
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0897
BI: Parking axis selection / Parking axis sel
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r0898.0...15
CO/BO: Control word drive object 1 / STW DO1
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0898.0...14
CO/BO: Control word sequence control / STW seq_ctrl
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2501
VECTOR_AC
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
970
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0898.0...14
CO/BO: Control word sequence control / STW seq_ctrl
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: -
Function diagram: 2501
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0898.0...10
CO/BO: Control word sequence control infeed / STW seq_ctrl INF
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 8820, 8920
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0898.0...10
CO/BO: Control word sequence control infeed / STW seq_ctrl INF
B_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 8720
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0898.0...13
CO/BO: Control word sequence control / STW seq_ctrl
TM41
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 9678
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0898.10
CO/BO: Control word sequence control encoder DO / STW seq_ctrl encDO
ENC
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0899.0...15
CO/BO: Status word drive object 1 / ZSW DO1
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
971
SINAMICS parameters
3.2 SINAMICS parameters
r0899.0...13
CO/BO: Status word sequence control / ZSW seq_ctrl
HLA
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0899.0...15
CO/BO: Status word sequence control / ZSW seq_ctrl
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: 2503
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0899.0...12
CO/BO: Status word sequence control infeed / ZSW seq_ctrl INF
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 8826, 8926
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0899.0...12
CO/BO: Status word sequence control infeed / ZSW seq_ctrl INF
B_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 8726
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0899.0...15
CO/BO: Status word sequence control / ZSW seq_ctrl
TM41
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 9680
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0899.7...9
CO/BO: Status word sequence control encoder DO / ZSW seq_ctrl encDO
ENC
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
972
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0915[0...29]
TM15 PROFIdrive PZD setpoint assignment / TM15 PD PZD set
TM15
Can be changed: T
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4273
[0] 4201
[1] 4204
[2] 4205
[3] 4211
[4] 4212
[5] 4213
[6...29] 0
p0915[0...35]
TM17 PROFIdrive PZD setpoint assignment / TM17 PD PZD set
TM17
Can be changed: T
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4265
[0] 4201
[1] 4204
[2] 4211
[3] 4212
[4...35] 0
p0916[0...29]
TM15 PROFIdrive PZD actual value assignment / TM15 PD PZD ActV
TM15
Can be changed: T
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4373
[0] 4301
[1] 4304
[2] 4305
[3] 4311
[4] 4312
[5] 4313
[6...29] 0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
973
SINAMICS parameters
3.2 SINAMICS parameters
p0916[0...35]
TM17 PROFIdrive PZD actual value assignment / TM17 PD PZD ActV
TM17
Can be changed: T
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4365
[0] 4301
[1] 4304
[2] 4311
[3] 4312
[4...35] 0
p0918
PROFIBUS address / PB address
CU_S_AC_PN,
Can be changed: T
Calculated: -
Access level: 9
CU_S120_PN
Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
126
126
p0918
PROFIBUS address / PB address
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 2
CU_S120_DP
Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 2410
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
126
126
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD tel
CU_S_AC_DP,
Can be changed: C2(1), T
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 2420,
CU_S120_DP,
2423, 2481, 2483
CU_S120_PN
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
390
999
999
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD tel
HLA
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 2415,
2416, 2419, 2420, 2421, 2422,
2423
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
166
999
999
Machine data and parameters
974
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD tel
SERVO, SERVO_AC
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 2415,
2416, 2419, 2420, 2421, 2422,
2423
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
999
999
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD tel
SERVO (EPOS, EPOS,
Can be changed: C2(1), T
Calculated: -
Access level: 1
Pos ctrl, Pos ctrl,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 2415,
Spin_diag), SERVO_AC
2416, 2419, 2420, 2421, 2422,
(EPOS, EPOS, Pos ctrl,
2423
Pos ctrl, Spin_diag)
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
7
999
999
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD tel
SERVO (Pos ctrl, Pos
Can be changed: C2(1), T
Calculated: -
Access level: 1
ctrl, Spin_diag),
Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 2415,
SERVO_AC (Pos ctrl, Pos
2416, 2419, 2420, 2421, 2422,
ctrl, Spin_diag)
2423
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
999
999
999
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD tel
SERVO (Spin_diag),
Can be changed: C2(1), T
Calculated: -
Access level: 1
SERVO_AC (Spin_diag) Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 2415,
2416, 2419, 2420, 2421, 2422,
2423
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
999
999
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD tel
VECTOR, VECTOR_AC
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 2415,
2416, 2419, 2420, 2421, 2422,
2423
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
999
999
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
975
SINAMICS parameters
3.2 SINAMICS parameters
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD tel
VECTOR (EPOS, EPOS,
Can be changed: C2(1), T
Calculated: -
Access level: 1
n/M, Pos ctrl, Pos ctrl),
Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 2415,
VECTOR_AC (EPOS,
2416, 2419, 2420, 2421, 2422,
EPOS, n/M, Pos ctrl, Pos
2423
ctrl)
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
7
999
999
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD tel
VECTOR (n/M, Pos ctrl,
Can be changed: C2(1), T
Calculated: -
Access level: 1
Pos ctrl), VECTOR_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 2415,
(n/M, Pos ctrl, Pos ctrl)
2416, 2419, 2420, 2421, 2422,
2423
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
999
999
999
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD tel
VECTOR (n/M),
Can be changed: C2(1), T
Calculated: -
Access level: 1
VECTOR_AC (n/M)
Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 2415,
2416, 2419, 2420, 2421, 2422,
2423
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
999
999
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD tel
A_INF, B_INF, R_INF,
Can be changed: C2(1), T
Calculated: -
Access level: 1
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 2420,
2423, 2447, 2457, 2481, 2483
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
370
999
999
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD tel
TM15, TM17
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: 2481, 2483
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
0
0
Machine data and parameters
976
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD tel
TM41
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 9677,
9679, 9681, 9683
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
3
999
999
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD tel
ENC
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: 2401, 2415,
2416, 2419, 2420, 2421, 2422,
2423
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
81
999
999
r0924[0...1]
ZSW bit pulses enabled / ZSW pulse enab
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2454, 2456
VECTOR_AC
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0925
PROFIdrive clock synchronous sign-of-life tolerance / PD SoL_tol
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: 2410
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HLA, SERVO,
Not for motor type: -
Scaling: -
Expert list: 1
SERVO_AC, TM41,
Min:
Max:
Factory setting:
VECTOR (n/M),
0
65535
1
VECTOR_AC (n/M)
r0930
PROFIdrive operating mode / PD operating mode
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
977
SINAMICS parameters
3.2 SINAMICS parameters
r0944
CO: Counter for fault buffer changes / Fault buff change
All objects
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0945[0...63]
Fault code / Fault code
All objects
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 8050, 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0946[0...65534]
Fault code list / Fault code list
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r0947[0...63]
Fault number / Fault number
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 8050, 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0948[0...63]
Fault time received in milliseconds / t_fault recv ms
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 8050, 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
r0949[0...63]
Fault value / Fault value
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: -
Function diagram: 8050, 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
978
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0952
Fault cases counter / Fault cases qty
All objects
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 6700, 8060
P-Group: Messages
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
r0963
PROFIBUS baud rate / PB baud rate
CU_S_AC_PN,
Can be changed: -
Calculated: -
Access level: 9
CU_S120_PN
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
255
-
r0963
PROFIBUS baud rate / PB baud rate
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S120_DP
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
-
r0964[0...6]
Device identification / Device ID
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0965
PROFIdrive profile number profile version / PD profile nr vers
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Communications
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0969
System runtime relative / t_system relative
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: 8050, 8060
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
4294967295 [ms]
0 [ms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
979
SINAMICS parameters
3.2 SINAMICS parameters
p0970
Reset drive parameters / Drive par reset
HLA
Can be changed: C2(30)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
0
p0970
Reset drive parameters / Drive par reset
SERVO, SERVO_AC,
Can be changed: C2(30)
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
0
p0970
Reset infeed parameter / INF par reset
A_INF, B_INF, R_INF,
Can be changed: C2(30)
Calculated: -
Access level: 2
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
0
p0970
TM120 reset parameters / TM120 par reset
TM120
Can be changed: C2(30)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
0
p0970
TM15 reset parameter / TM15 par reset
TM15
Can be changed: C2(30)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
0
p0970
TM150 reset parameters / TM150 par reset
TM150
Can be changed: C2(30)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
0
Machine data and parameters
980
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0970
TM15DI/DO reset parameter / TM15D par reset
TM15DI_DO
Can be changed: C2(30)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
0
p0970
TM17 reset parameter / TM17 par reset
TM17
Can be changed: C2(30)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
0
p0970
TM31 reset parameters / TM31 par reset
TM31
Can be changed: C2(30)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
0
p0970
TM41 reset parameters / TM41 par reset
TM41
Can be changed: C2(30)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
0
p0970
TB30 reset parameters / TB30 par reset
TB30
Can be changed: C2(30)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
0
p0970
TM54F reset parameters / TM54F par reset
TM54F_MA
Can be changed: C2(30)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
981
SINAMICS parameters
3.2 SINAMICS parameters
p0970
TM54F reset parameters / TM54F par reset
TM54F_SL
Can be changed: C2(30)
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
0
p0970
ENCODER reset parameters / ENC par reset
ENC
Can be changed: C2(30)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
100
0
p0971
Save drive object parameters / DO par save
All objects
Can be changed: T, U
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Factory settings
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0972
Drive unit reset / Drv_unit reset
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: All groups
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
r0975[0...10]
Drive object identification / DO identification
All objects
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0976
Reset and load all parameters / Reset load all par
CU_S_AC_DP,
Can be changed: C1(30), C2(30)
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Factory settings
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1013
0
Machine data and parameters
982
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0977
Save all parameters / Save all par
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Factory settings
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1013
0
p0978[0...n]
List of drive objects / List of the DO
CU_S_AC_DP,
Can be changed: C1(1)
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: r0579
Function diagram: -
CU_S120_DP,
P-Group: Topology
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
[0] 1
[1...24] 0
r0979[0...30]
PROFIdrive encoder format / PD encoder format
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: 4704
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0979[0...30]
PROFIdrive encoder format / PD encoder format
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32
Dynamic index: -
Function diagram: 4704
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0979[0...10]
PROFIdrive encoder format / PD encoder format
ENC, TM41
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 4704
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0979[0...10]
PROFIdrive encoder format / PD encoder format
ENC (Lin_enc)
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 4704
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
983
SINAMICS parameters
3.2 SINAMICS parameters
r0980[0...299]
List of existing parameters 1 / List avail par 1
All objects
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r0981[0...299]
List of existing parameters 2 / List avail par 2
All objects
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r0989[0...299]
List of existing parameters 10 / List avail par 10
All objects
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r0990[0...99]
List of modified parameters 1 / List chang par 1
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r0991[0...99]
List of modified parameters 2 / List chang par 2
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r0999[0...99]
List of modified parameters 10 / List chang par 10
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
984
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1000[0...n]
Macro Connector Inputs (CI) for speed setpoints / Macro CI n_set
HLA, SERVO,
Can be changed: C2(1), T
Calculated: -
Access level: 1
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: CDS, p0170 Function diagram: -
VECTOR_AC
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
999999
0
p1000[0...n]
Macro Connector Inputs (CI) for velocity setpoints / Macro CI v_set
SERVO (Lin),
Can be changed: C2(1), T
Calculated: -
Access level: 1
SERVO_AC (Lin)
Data type: Unsigned32
Dynamic index: CDS, p0170 Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
999999
0
p1000[0...n]
Macro Connector Inputs (CI) for speed setpoints / Macro CI n_set
A_INF, B_INF, R_INF,
Can be changed: C2(1), T
Calculated: -
Access level: 8
S_INF
Data type: Unsigned32
Dynamic index: CDS, p0170
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
999999
0
p1001[0...n]
CO: Fixed velocity setpoint 1 / v_set_fix 1
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1001[0...n]
CO: Fixed speed setpoint 1 / n_set_fix 1
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1002[0...n]
CO: Fixed velocity setpoint 2 / v_set_fix 2
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
985
SINAMICS parameters
3.2 SINAMICS parameters
p1002[0...n]
CO: Fixed speed setpoint 2 / n_set_fix 2
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1003[0...n]
CO: Fixed velocity setpoint 3 / v_set_fix 3
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1003[0...n]
CO: Fixed speed setpoint 3 / n_set_fix 3
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1004[0...n]
CO: Fixed velocity setpoint 4 / v_set_fix 4
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1004[0...n]
CO: Fixed speed setpoint 4 / n_set_fix 4
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1005[0...n]
CO: Fixed velocity setpoint 5 / v_set_fix 5
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
Machine data and parameters
986
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1005[0...n]
CO: Fixed speed setpoint 5 / n_set_fix 5
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1006[0...n]
CO: Fixed velocity setpoint 6 / v_set_fix 6
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1006[0...n]
CO: Fixed speed setpoint 6 / n_set_fix 6
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1007[0...n]
CO: Fixed velocity setpoint 7 / v_set_fix 7
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1007[0...n]
CO: Fixed speed setpoint 7 / n_set_fix 7
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1008[0...n]
CO: Fixed velocity setpoint 8 / v_set_fix 8
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
987
SINAMICS parameters
3.2 SINAMICS parameters
p1008[0...n]
CO: Fixed speed setpoint 8 / n_set_fix 8
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1009[0...n]
CO: Fixed velocity setpoint 9 / v_set_fix 9
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1009[0...n]
CO: Fixed speed setpoint 9 / n_set_fix 9
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1010[0...n]
CO: Fixed velocity setpoint 10 / v_set_fix 10
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1010[0...n]
CO: Fixed speed setpoint 10 / n_set_fix 10
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1011[0...n]
CO: Fixed velocity setpoint 11 / v_set_fix 11
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
Machine data and parameters
988
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1011[0...n]
CO: Fixed speed setpoint 11 / n_set_fix 11
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1012[0...n]
CO: Fixed velocity setpoint 12 / v_set_fix 12
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1012[0...n]
CO: Fixed speed setpoint 12 / n_set_fix 12
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1013[0...n]
CO: Fixed velocity setpoint 13 / v_set_fix 13
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1013[0...n]
CO: Fixed speed setpoint 13 / n_set_fix 13
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1014[0...n]
CO: Fixed velocity setpoint 14 / v_set_fix 14
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
989
SINAMICS parameters
3.2 SINAMICS parameters
p1014[0...n]
CO: Fixed speed setpoint 14 / n_set_fix 14
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1015[0...n]
CO: Fixed velocity setpoint 15 / v_set_fix 15
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1015[0...n]
CO: Fixed speed setpoint 15 / n_set_fix 15
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1020[0...n]
BI: Fixed velocity setpoint selection Bit 0 / v_set_fixed bit 0
SERVO (Ext setp, Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3010
Lin)
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1020[0...n]
BI: Fixed speed setpoint selection bit 0 / n_set_fixed bit 0
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp)
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3010
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1020[0...n]
BI: Fixed speed setpoint selection bit 0 / n_set_fixed bit 0
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3010,
3011
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
990
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1021[0...n]
BI: Fixed velocity setpoint selection Bit 1 / v_set_fixed bit 1
SERVO (Ext setp, Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3010
Lin)
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1021[0...n]
BI: Fixed speed setpoint selection bit 1 / n_set_fixed bit 1
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp)
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3010
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1021[0...n]
BI: Fixed speed setpoint selection bit 1 / n_set_fixed bit 1
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3010,
3011
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1022[0...n]
BI: Fixed velocity setpoint selection Bit 2 / v_set_fixed bit 2
SERVO (Ext setp, Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3010
Lin)
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1022[0...n]
BI: Fixed speed setpoint selection bit 2 / n_set_fixed bit 2
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp)
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3010
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1022[0...n]
BI: Fixed speed setpoint selection bit 2 / n_set_fixed bit 2
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3010,
3011
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
991
SINAMICS parameters
3.2 SINAMICS parameters
p1023[0...n]
BI: Fixed velocity setpoint selection Bit 3 / v_set_fixed bit 3
SERVO (Ext setp, Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3010
Lin)
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1023[0...n]
BI: Fixed speed setpoint selection bit 3 / n_set_fixed bit 3
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp)
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3010
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1023[0...n]
BI: Fixed speed setpoint selection bit 3 / n_set_fixed bit 3
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3010,
3011
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r1024
CO: Fixed velocity setpoint effective / v_set_fix eff
SERVO (Ext setp, Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3010
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1024
CO: Fixed speed setpoint effective / n_set_fix eff
SERVO (Ext setp),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3010
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1024
CO: Fixed speed setpoint effective / n_set_fix eff
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3010,
3011
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
Machine data and parameters
992
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1030[0...n]
Motorized potentiometer configuration / MoP configuration
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: 3020
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0110 bin
p1035[0...n]
BI: Motorized potentiometer setpoint raise / MoP raise
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3020
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1035
BI: Zero marks enable / ZM enable
TM41
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9677
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1036[0...n]
BI: Motorized potentiometer lower setpoint / MoP lower
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3020
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1037[0...n]
Motorized potentiometer maximum velocity / MoP n_max
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated:
Access level: 2
SERVO_AC (Ext setp,
CALC_MOD_LIM_REF
Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3020
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1037[0...n]
Motorized potentiometer maximum speed / MoP n_max
SERVO (Ext setp),
Can be changed: T, U
Calculated:
Access level: 2
SERVO_AC (Ext setp),
CALC_MOD_LIM_REF
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3020
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
993
SINAMICS parameters
3.2 SINAMICS parameters
p1038[0...n]
Motorized potentiometer minimum velocity / MoP n_min
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated:
Access level: 2
SERVO_AC (Ext setp,
CALC_MOD_LIM_REF
Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3020
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1038[0...n]
Motorized potentiometer minimum speed / MoP n_min
SERVO (Ext setp),
Can be changed: T, U
Calculated:
Access level: 2
SERVO_AC (Ext setp),
CALC_MOD_LIM_REF
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3020
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1039[0...n]
BI: Motorized potentiometer inversion / MoP inv
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 3020
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1040[0...n]
Motorized potentiometer starting value / MoP start value
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3020
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1040[0...n]
Motorized potentiometer starting value / MoP start value
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3020
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1041[0...n]
BI: Motorized potentiometer manual/automatic / MoP manual/auto
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 3020
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
994
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1042[0...n]
CI: Motorized potentiometer automatic setpoint / MoP auto setpoint
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 3020
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1043[0...n]
BI: Motorized potentiometer accept setting value / MoP acc set val
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 3020
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1044[0...n]
CI: Motorized potentiometer setting value / MoP set val
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 3020
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r1045
CO: Mot. potentiom. velocity setp. in front of ramp-fct. gen. / MoP n_set bef RFG
SERVO (Ext setp, Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3020
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1045
CO: Mot. potentiometer speed setp. in front of ramp-fct. gen. / MoP n_set bef RFG
SERVO (Ext setp),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3020
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1047[0...n]
Motorized potentiometer ramp-up time / MoP ramp-up time
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 3020
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
1000.000 [s]
10.000 [s]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
995
SINAMICS parameters
3.2 SINAMICS parameters
p1048[0...n]
Motorized potentiometer ramp-down time / MoP ramp-down time
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 3020
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
1000.000 [s]
10.000 [s]
r1050
CO: Motorized potentiometer setpoint after ramp-function generator / MoP set after RFG
SERVO (Ext setp, Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3020
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1050
CO: Motorized potentiometer setpoint after ramp-function generator / MoP set after RFG
SERVO (Ext setp),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3020
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1051[0...n]
CI: Velocity limit RFG positive direction / v_limit RFG pos
SERVO (ESR, ESR, Ext
Can be changed: T
Calculated: -
Access level: 3
setp, Ext setp, Lin, Lin,
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 3050
Lin), SERVO_AC (ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
ESR, Ext setp, Ext setp,
Lin, Lin, Lin)
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
1083[0]
p1051[0...n]
CI: Speed limit RFG positive direction of rotation / n_limit RFG pos
HLA (ESR), SERVO (ESR,
Can be changed: T
Calculated: -
Access level: 3
ESR, Ext setp, Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 3050
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
1083[0]
p1052[0...n]
CI: Velocity limit RFG negative direction / v_limit RFG neg
SERVO (ESR, ESR, Ext
Can be changed: T
Calculated: -
Access level: 3
setp, Ext setp, Lin, Lin,
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 3050
Lin), SERVO_AC (ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
ESR, Ext setp, Ext setp,
Lin, Lin, Lin)
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
1086[0]
Machine data and parameters
996
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1052[0...n]
CI: Speed limit RFG negative direction of rotation / n_limit RFG neg
HLA (ESR), SERVO (ESR,
Can be changed: T
Calculated: -
Access level: 3
ESR, Ext setp, Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3050
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
1086[0]
p1055[0...n]
BI: Jog bit 0 / Jog bit 0
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2501, 3030
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1056[0...n]
BI: Jog bit 1 / Jog bit 1
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2501, 3030
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1058[0...n]
Jog 1 velocity setpoint / Jog 1 v_set
SERVO (Ext setp, Lin),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3001, 3030
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1058[0...n]
Jog 1 speed setpoint / Jog 1 n_set
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3001, 3030
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1059[0...n]
Jog 2 velocity setpoint / Jog 2 v_set
SERVO (Ext setp, Lin),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3001, 3030
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
997
SINAMICS parameters
3.2 SINAMICS parameters
p1059[0...n]
Jog 2 speed setpoint / Jog 2 n_set
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3001, 3030
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1063[0...n]
Setpoint channel velocity limit / Set_chan v_lim
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3040
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [m/min]
1000.000 [m/min]
1000.000 [m/min]
p1063[0...n]
Setpoint channel speed limit / Set_chan n_lim
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Ext setp)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3040
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [rpm]
210000.000 [rpm]
210000.000 [rpm]
p1063[0...n]
Setpoint channel speed limit / Set_chan n_lim
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3040
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [rpm]
210000.000 [rpm]
40000.000 [rpm]
p1070[0...n]
CI: Main setpoint / Main setpoint
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3001, 3030
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
1024[0]
p1071[0...n]
CI: Main setpoint scaling / Main set scal
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3001, 3030
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
998
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1073
CO: Main setpoint effective / Main setpoint eff
SERVO (Ext setp, Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3030
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1073
CO: Main setpoint effective / Main setpoint eff
SERVO (Ext setp),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3030
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1075[0...n]
CI: Supplementary setp / Suppl set
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3001, 3030
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1076[0...n]
CI: Supplementary setpoint scaling / Suppl set scal
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3001, 3030
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
r1077
CO: Supplementary setpoint effective / Suppl setpoint eff
SERVO (Ext setp, Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3030
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1077
CO: Supplementary setpoint effective / Suppl setpoint eff
SERVO (Ext setp),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3030
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
999
SINAMICS parameters
3.2 SINAMICS parameters
r1078
CO: Total setpoint effective / Total setpoint eff
SERVO (Ext setp, Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3030
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1078
CO: Total setpoint effective / Total setpoint eff
SERVO (Ext setp),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3030
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1079
Interpolator clock cycle for speed setpoints / Interp_cyc n_set
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
127.00 [ms]
0.00 [ms]
p1080[0...n]
Minimum velocity / v_min
SERVO (Ext setp, Lin),
Can be changed: C2(1), T
Calculated: -
Access level: 1
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1080[0...n]
Minimum speed / n_min
SERVO (Ext setp),
Can be changed: C2(1), T
Calculated: -
Access level: 1
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [rpm]
19500.000 [rpm]
0.000 [rpm]
p1081
Maximum speed scaling / n_max scal
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3050, 3095
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
100.00 [%]
105.00 [%]
100.00 [%]
Machine data and parameters
1000
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1081
Maximum velocity scaling / v_max scal
HLA, SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3050, 3095
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
100.00 [%]
105.00 [%]
100.00 [%]
p1082[0...n]
Maximum velocity / v_max
HLA
Can be changed: C2(1), T
Calculated:
Access level: 1
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [m/min]
1000.000 [m/min]
1000.000 [m/min]
p1082[0...n]
Maximum speed / n_max
SERVO, SERVO_AC
Can be changed: C2(1), T
Calculated: CALC_MOD_ALL
Access level: 1
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 2820, 3020,
3050, 3060, 3070, 3095
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [rpm]
210000.000 [rpm]
1500.000 [rpm]
p1082[0...n]
Maximum velocity / v_max
SERVO (Lin),
Can be changed: C2(1), T
Calculated: CALC_MOD_ALL
Access level: 1
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 2820, 3020,
3050, 3060, 3070, 3095
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [m/min]
1300.000 [m/min]
1000.000 [m/min]
p1082[0...n]
Maximum speed / n_max
VECTOR, VECTOR_AC
Can be changed: C2(1), T
Calculated: CALC_MOD_ALL
Access level: 1
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 2820, 3020,
3050, 3060, 3070, 3095
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [rpm]
210000.000 [rpm]
1500.000 [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1001
SINAMICS parameters
3.2 SINAMICS parameters
r1082[0...n]
Encoder emulation maximum speed / Enc_emul n_max
TM41
Can be changed: -
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 9674, 9676
P-Group: -
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1083[0...n]
CO: Velocity limit positive direction / v_limit pos
HLA
Can be changed: T, U
Calculated:
Access level: 2
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [m/min]
1000.000 [m/min]
1000.000 [m/min]
p1083[0...n]
CO: Speed limit in positive direction of rotation / n_limit pos
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050, 3095
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [rpm]
210000.000 [rpm]
210000.000 [rpm]
p1083[0...n]
CO: Velocity limit positive direction / v_limit pos
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050, 3095
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [m/min]
1000.000 [m/min]
1000.000 [m/min]
p1083[0...n]
CO: Speed limit in positive direction of rotation / n_limit pos
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050, 6732
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [rpm]
210000.000 [rpm]
40000.000 [rpm]
r1084
CO: Velocity limit positive effective / v_limit pos eff
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
Machine data and parameters
1002
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1084
CO: Speed limit positive effective / n_limit pos eff
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3050, 3095
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1084
CO: Velocity limit positive effective / v_limit pos eff
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3050, 3095
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1084
CO: Speed limit positive effective / n_limit pos eff
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3050, 3095
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1085[0...n]
CI: Velocity limit positive direction / v_limit pos
SERVO (Ext setp, Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3050
Lin)
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
1083[0]
p1085[0...n]
CI: Speed limit in positive direction of rotation / n_limit pos
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3050
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
1083[0]
p1086[0...n]
CO: Velocity limit negative direction / v_limit neg
HLA
Can be changed: T, U
Calculated:
Access level: 2
CALC_MOD_LIM_REF
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 4965
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
0.000 [m/min]
-1000.000 [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1003
SINAMICS parameters
3.2 SINAMICS parameters
p1086[0...n]
CO: Speed limit in negative direction of rotation / n_limit neg
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050, 3095
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
0.000 [rpm]
-210000.000 [rpm]
p1086[0...n]
CO: Velocity limit negative direction / v_limit neg
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050, 3095
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-1000.000 [m/min]
0.000 [m/min]
-1000.000 [m/min]
p1086[0...n]
CO: Speed limit in negative direction of rotation / n_limit neg
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-210000.000 [rpm]
0.000 [rpm]
-40000.000 [rpm]
r1087
CO: Velocity limit negative effective / v_limit neg eff
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1087
CO: Speed limit negative effective / n_limit neg eff
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3050, 3095
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1087
CO: Velocity limit negative effective / v_limit neg eff
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3050, 3095
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
Machine data and parameters
1004
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1087
CO: Speed limit negative effective / n_limit neg eff
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3050, 3095
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1088[0...n]
CI: Velocity limit negative direction / n_limit neg
SERVO (Ext setp, Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3050
Lin)
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
1086[0]
p1088[0...n]
CI: Speed limit in negative direction of rotation / n_limit neg
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3050
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
1086[0]
p1091[0...n]
Skip velocity 1 / v_skip 1
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1091[0...n]
Skip speed 1 / n_skip 1
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1092[0...n]
Skip velocity 2 / v_skip 2
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1005
SINAMICS parameters
3.2 SINAMICS parameters
p1092[0...n]
Skip speed 2 / n_skip 2
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1093[0...n]
Skip velocity 3 / v_skip 3
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1093[0...n]
Skip speed 3 / n_skip 3
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1094[0...n]
Skip velocity 4 / v_skip 4
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1094[0...n]
Skip speed 4 / n_skip 4
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1098[0...n]
CI: Skip velocity scaling / v_skip scal
SERVO (Ext setp, Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3050
Lin)
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
1006
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1098[0...n]
CI: Skip speed scaling / n_skip scal
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3050
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
r1099.0
CO/BO: Skip band status word / Skip band ZSW
SERVO (Ext setp),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1101[0...n]
Skip velocity bandwidth / v_skip bandwidth
SERVO (Ext setp, Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
p1101[0...n]
Skip speed bandwidth / n_skip bandwidth
SERVO (Ext setp),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3050
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
0.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1106[0...n]
CI: Minimum velocity signal source / v_min s_s
SERVO (Ext setp, Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3050
Lin)
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1106[0...n]
CI: Minimum speed signal source / n_min s_s
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3050
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1007
SINAMICS parameters
3.2 SINAMICS parameters
p1108[0...n]
BI: Total setpoint selection / Total set sel
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 3030
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
p1109[0...n]
CI: Total setpoint / Total setp
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3030
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
p1110[0...n]
BI: Inhibit negative direction / Inhib neg dir
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3040
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1111[0...n]
BI: Inhibit positive direction / Inhib pos dir
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3040
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r1112
CO: Velocity setpoint after minimum limiting / v_set aft min_lim
SERVO (Ext setp, Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3050
Lin)
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1112
CO: Speed setpoint after minimum limiting / n_set aft min_lim
SERVO (Ext setp),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3050
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
Machine data and parameters
1008
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1113[0...n]
BI: Setpoint inversion / Set inv
SERVO (Ext setp),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2441, 2442,
VECTOR, VECTOR_AC
2505, 3040
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r1114
CO: Setpoint after the direction limiting / Set after limit
SERVO (Ext setp, Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3040,
Lin)
3050
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1114
CO: Setpoint after the direction limiting / Set after limit
SERVO (Ext setp),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3040,
VECTOR, VECTOR_AC
3050
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1115
Ramp-function generator selection / RFG selection
HLA (ESR), SERVO (ESR,
Can be changed: T
Calculated: -
Access level: 3
ESR, Ext setp, Ext setp),
Data type: Integer16
Dynamic index: -
Function diagram: 3001, 3080
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
r1119
CO: Ramp-function generator setpoint at the input / RFG set at inp
HLA (ESR)
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1009
SINAMICS parameters
3.2 SINAMICS parameters
r1119
CO: Ramp-function generator setpoint at the input / RFG set at inp
SERVO (ESR, ESR, Ext
Can be changed: -
Calculated: -
Access level: 3
setp, Ext setp, Lin, Lin,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3050,
Lin), SERVO_AC (ESR,
3060, 3070, 6300
ESR, Ext setp, Ext setp,
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Lin, Lin, Lin)
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1119
CO: Ramp-function generator setpoint at the input / RFG set at inp
SERVO (ESR, ESR, Ext
Can be changed: -
Calculated: -
Access level: 3
setp, Ext setp),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3050,
SERVO_AC (ESR, ESR,
3060, 3070, 6300
Ext setp, Ext setp),
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1120[0...n]
Ramp-function generator ramp-up time / RFG ramp-up time
HLA (ESR)
Can be changed: C2(1), T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3060, 3070
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
999999.000 [s]
10.000 [s]
p1120[0...n]
Ramp-function generator ramp-up time / RFG ramp-up time
SERVO (ESR, ESR, Ext
Can be changed: C2(1), T, U
Calculated: -
Access level: 1
setp, Ext setp, Lin, Lin,
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3060, 3070
Lin), SERVO_AC (ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
ESR, Ext setp, Ext setp,
Lin, Lin, Lin)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
999999.000 [s]
10.000 [s]
p1120[0...n]
Ramp-function generator ramp-up time / RFG ramp-up time
SERVO (ESR, ESR, Ext
Can be changed: C2(1), T, U
Calculated: -
Access level: 1
setp, Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3060, 3070
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
999999.000 [s]
10.000 [s]
p1120[0...n]
Ramp-function generator ramp-up time / RFG ramp-up time
VECTOR, VECTOR_AC
Can be changed: C2(1), T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3060, 3070
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
999999.000 [s]
10.000 [s]
Machine data and parameters
1010
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1121[0...n]
Ramp-function generator ramp-down time / RFG ramp-down time
HLA
Can be changed: C2(1), T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
999999.000 [s]
0.000 [s]
p1121[0...n]
Ramp-function generator ramp-down time / RFG ramp-down time
SERVO, SERVO_AC
Can be changed: C2(1), T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 3060, 3070
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
999999.000 [s]
10.000 [s]
p1121[0...n]
Ramp-function generator ramp-down time / RFG ramp-down time
SERVO (Lin),
Can be changed: C2(1), T, U
Calculated: -
Access level: 1
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 3060, 3070
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
999999.000 [s]
0.000 [s]
p1121[0...n]
Ramp-function generator ramp-down time / RFG ramp-down time
VECTOR, VECTOR_AC
Can be changed: C2(1), T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 3060, 3070
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
999999.000 [s]
10.000 [s]
p1122[0...n]
BI: Bypass ramp-function generator / Bypass RFG
HLA (ESR), SERVO (ESR,
Can be changed: T, U
Calculated: -
Access level: 3
ESR, Ext setp, Ext setp),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2505
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1130[0...n]
Ramp-function generator initial rounding-off time / RFG t_start_round
HLA (ESR), SERVO (ESR,
Can be changed: T, U
Calculated: -
Access level: 2
ESR, Ext setp, Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 3070
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
30.000 [s]
0.000 [s]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1011
SINAMICS parameters
3.2 SINAMICS parameters
p1131[0...n]
Ramp-function generator final rounding-off time / RFG t_end_delay
HLA (ESR), SERVO (ESR,
Can be changed: T, U
Calculated: -
Access level: 2
ESR, Ext setp, Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 3070
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
30.000 [s]
0.000 [s]
p1134[0...n]
Ramp-function generator rounding-off type / RFG round-off type
HLA (ESR), SERVO (ESR,
Can be changed: T, U
Calculated: -
Access level: 2
ESR, Ext setp, Ext setp),
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 3070
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1135[0...n]
OFF3 ramp-down time / OFF3 t_RD
HLA, SERVO, SERVO_AC Can be changed: C2(1), T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3060, 3070
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
600.000 [s]
0.000 [s]
p1135[0...n]
OFF3 ramp-down time / OFF3 t_RD
SERVO (Lin),
Can be changed: C2(1), T, U
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3060, 3070
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
600.000 [s]
0.000 [s]
p1135[0...n]
OFF3 ramp-down time / OFF3 t_RD
VECTOR, VECTOR_AC
Can be changed: C2(1), T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3060, 3070
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
600.000 [s]
3.000 [s]
p1136[0...n]
OFF3 initial rounding-off time / RFGOFF3 t_strt_rnd
HLA (ESR), SERVO (ESR,
Can be changed: T, U
Calculated: -
Access level: 2
ESR, Ext setp, Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3070
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
30.000 [s]
0.000 [s]
Machine data and parameters
1012
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1137[0...n]
OFF3 final rounding-off time / RFG OFF3 t_end_del
HLA (ESR), SERVO (ESR,
Can be changed: T, U
Calculated: -
Access level: 2
ESR, Ext setp, Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 3070
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
30.000 [s]
0.000 [s]
p1138[0...n]
CI: Ramp-function generator ramp-up time scaling / RFG t_RU scal
HLA (ESR), SERVO (ESR,
Can be changed: T
Calculated: -
Access level: 3
ESR, Ext setp, Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 3060, 3070
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1139[0...n]
CI: Ramp-function generator ramp-down time scaling / RFG t_RD scal
HLA (ESR), SERVO (ESR,
Can be changed: T
Calculated: -
Access level: 3
ESR, Ext setp, Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 3060, 3070
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1140[0...n]
BI: Enable ramp-function generator/inhibit ramp-function generator / Enable RFG
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2501
VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1140
BI: Enable ramp-function generator/inhibit ramp-function generator / Enable RFG
TM41
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9678
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1141[0...n]
BI: Continue ramp-function generator/freeze ramp-function generator / Continue RFG
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2501
VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1013
SINAMICS parameters
3.2 SINAMICS parameters
p1141
BI: Continue ramp-function generator/freeze ramp-function generator / Continue RFG
TM41
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9678
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1142[0...n]
BI: Enable setpoint/inhibit setpoint / Setpoint enable
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2501
VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1142
BI: Enable setpoint/inhibit setpoint / Setpoint enable
TM41
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9674, 9678
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1143[0...n]
BI: Ramp-function generator, accept setting value / RFG accept set val
HLA (ESR), SERVO (ESR,
Can be changed: T
Calculated: -
Access level: 3
ESR, Ext setp, Ext setp),
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 3060, 3070
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1144[0...n]
CI: Ramp-function generator setting value / RFG setting value
HLA (ESR), SERVO (ESR,
Can be changed: T, U
Calculated: -
Access level: 3
ESR, Ext setp, Ext setp),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 3060, 3070
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1145[0...n]
Ramp-function generator tracking intensity. / RFG track intens
SERVO (ESR, ESR, Ext
Can be changed: T, U
Calculated: -
Access level: 3
setp, Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 3080
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0
50.0
1.3
Machine data and parameters
1014
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1145[0...n]
Ramp-function generator tracking intensity. / RFG track intens
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 3080
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0
50.0
1.3
p1148[0...n]
Ramp-function gen. tolerance for ramp-up and ramp-down active / RFG tol HL/RL act
HLA (ESR), SERVO (ESR,
Can be changed: T, U
Calculated: -
Access level: 3
ESR, Ext setp, Ext setp,
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 3060, 3070
Lin, Lin, Lin),
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
SERVO_AC (ESR, ESR,
Ext setp, Ext setp, Lin,
Not for motor type: -
Scaling: -
Expert list: 1
Lin, Lin)
Min:
Max:
Factory setting:
0.000 [m/min]
10.000 [m/min]
0.200 [m/min]
p1148[0...n]
Ramp-function gen. tolerance for ramp-up and ramp-down active / RFG tol HL/RL act
SERVO (ESR, ESR, Ext
Can be changed: T, U
Calculated: -
Access level: 3
setp, Ext setp),
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 3060, 3070
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [rpm]
1000.000 [rpm]
19.800 [rpm]
r1149
CO: Ramp-function generator acceleration / RFG acceleration
SERVO (ESR, ESR, Ext
Can be changed: -
Calculated: -
Access level: 3
setp, Ext setp, Lin, Lin,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3060, 3070
Lin), SERVO_AC (ESR,
P-Group: Setpoints
Unit group: 22_2
Unit selection: p0505
ESR, Ext setp, Ext setp,
Lin, Lin, Lin)
Not for motor type: -
Scaling: p2007
Expert list: 1
Min:
Max:
Factory setting:
- [m/s²]
- [m/s²]
- [m/s²]
r1149
CO: Ramp-function generator acceleration / RFG acceleration
HLA (ESR), SERVO (ESR,
Can be changed: -
Calculated: -
Access level: 3
ESR, Ext setp, Ext setp),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3060, 3070
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: 39_1
Unit selection: p0505
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: p2007
Expert list: 1
Min:
Max:
Factory setting:
- [rev/s²]
- [rev/s²]
- [rev/s²]
r1150
CO: Ramp-function generator velocity setpoint at the output / RFG v_set at outp
HLA (ESR), SERVO (ESR,
Can be changed: -
Calculated: -
Access level: 3
ESR, Ext setp, Ext setp,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3080
Lin, Lin, Lin),
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
SERVO_AC (ESR, ESR,
Ext setp, Ext setp, Lin,
Not for motor type: -
Scaling: p2000
Expert list: 1
Lin, Lin)
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1015
SINAMICS parameters
3.2 SINAMICS parameters
r1150
CO: Ramp-function generator speed setpoint at the output / RFG n_set at outp
SERVO (ESR, ESR, Ext
Can be changed: -
Calculated: -
Access level: 3
setp, Ext setp),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3080
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1151[0...n]
Ramp-function generator configuration / RFG config
SERVO (ESR, ESR, Ext
Can be changed: T, U
Calculated: -
Access level: 2
setp, Ext setp),
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: -
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p1152
BI: Setpoint 2 enable / Set 2 enab
SERVO (Ext brake),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Ext brake),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2711, 4015
VECTOR (Ext brake),
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR_AC (Ext brake)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
899.15
p1155[0...n]
CI: Speed controller speed setpoint 1 / n_ctrl n_set 1
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3001, 3080,
VECTOR_AC
5030, 6031
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1155[0...n]
CI: Velocity controller velocity setpoint 1 / v_ctrl v_set 1
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3001, 3080,
5030, 6031
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1155
CI: TM41 encoder emulation speed setpoint 1 / Enc_emulat n_set 1
TM41
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 9674
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1016
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1160[0...n]
CI: Speed controller speed setpoint 2 / n_ctrl n_set 2
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 3001, 3080
VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1160[0...n]
CI: Velocity controller velocity setpoint 2 / v_ctrl v_set 2
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170 Function diagram: 3001, 3080
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r1169
CO: Velocity controller velocity setpoints 1 and 2 / v_ctrl v_set 1/2
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1169
CO: Speed controller speed setpoints 1 and 2 / n_ctrl n_set 1/2
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3080
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1169
CO: Velocity controller velocity setpoints 1 and 2 / v_ctrl n_set 1/2
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3080
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1170
CO: Velocity controller setpoint sum / v_ctrl set sum
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1017
SINAMICS parameters
3.2 SINAMICS parameters
r1170
CO: Speed controller setpoint sum / n_ctrl set sum
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3050,
3080, 5019, 5020
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r1170
CO: Velocity controller setpoint sum / v_ctrl set sum
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3050,
3080, 5019, 5020
P-Group: Setpoints
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r1170
CO: Speed controller setpoint sum / n_ctrl set sum
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3080,
6300
P-Group: Setpoints
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
p1189[0...n]
Speed setpoint configuration / n_ctrl config
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: 3080
VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0011 bin
p1189[0...n]
Velocity setpoint configuration / v_ctrl config
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: 3080
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0011 bin
Machine data and parameters
1018
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1189
TM41 encoder simulation configuration / Enc_emulat config
TM41
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 9674
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0010 bin
p1190
CI: DSC position deviation XERR / DSC XERR
HLA, SERVO, SERVO_AC Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: 3001, 3090
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1191
CI: DSC position controller gain KPC / DSC KPC
HLA, SERVO, SERVO_AC Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 3001, 3090
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1192[0...n]
DSC encoder selection / DSC enc selection
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 3090
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
3
1
p1193[0...n]
DSC encoder adaptation factor / DSC enc adpt fact
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3090
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000000.00000
1000000.00000
1.00000
p1194
CI: DSC control word DSC_STW / DSC_STW
SERVO (DSC spline,
Can be changed: T
Calculated: -
Access level: 3
Lin), SERVO_AC (DSC
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 3001, 3090
spline, Lin)
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1019
SINAMICS parameters
3.2 SINAMICS parameters
p1194
CI: DSC control word DSC_STW / DSC_STW
SERVO (DSC spline),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (DSC spline)
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 3001, 3090
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1195
CI: DSC symmetrizing time constant T_SYMM / DSC Tc_SYMM
SERVO (DSC spline,
Can be changed: T
Calculated: -
Access level: 3
Lin), SERVO_AC (DSC
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 3001, 3090
spline, Lin)
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1195
CI: DSC symmetrizing time constant T_SYMM / DSC Tc_SYMM
SERVO (DSC spline),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (DSC spline)
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 3001, 3090
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r1196
CO: DSC position setpoint / DSC x_set
HLA, SERVO, SERVO_AC Can be changed: -
Calculated: -
Access level: 4
Data type: Integer32
Dynamic index: -
Function diagram: 3090
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1197
Fixed velocity setpoint number actual / n_set_fixed no act
SERVO (Ext setp, Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp,
Data type: Unsigned32
Dynamic index: -
Function diagram: 3010
Lin)
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1197
Fixed speed setpoint number actual / n_set_fixed no act
SERVO (Ext setp),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned32
Dynamic index: -
Function diagram: 3010
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1020
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1198.0...15
CO/BO: Control word setpoint channel / STW set chan
SERVO (Ext setp),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Ext setp),
Data type: Unsigned16
Dynamic index: -
Function diagram: 2505
VECTOR, VECTOR_AC
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1199.0...8
CO/BO: Ramp-function generator status word / RFG ZSW
HLA (ESR), SERVO (ESR,
Can be changed: -
Calculated: -
Access level: 3
ESR, Ext setp, Ext setp),
Data type: Unsigned16
Dynamic index: -
Function diagram: 3001, 3080
SERVO_AC (ESR, ESR,
P-Group: Setpoints
Unit group: -
Unit selection: -
Ext setp, Ext setp),
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1200
CI: Position offset incremental/absolute / x_offs inc/abs
HLA
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned32 / Integer32
Dynamic index: -
Function diagram: -
P-Group: Setpoints
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1200[0...n]
Flying restart operating mode / FlyRest op_mode
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 6300
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
0
p1201[0...n]
CI: Position offset incremental/absolute valid / x_offs valid
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Integer16
Dynamic index: CDS, p0170
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1201[0...n]
BI: Flying restart enable signal source / FlyRest enab s_s
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1021
SINAMICS parameters
3.2 SINAMICS parameters
p1202[0...n]
Flying restart search current / FlyRest I_srch
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10 [%]
400 [%]
100 [%]
p1203[0...n]
Flying restart search rate factor / FlyRes v_srch fact
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10 [%]
4000 [%]
100 [%]
r1204.0...15
CO/BO: Flying restart U/f control status / FlyRest Uf st
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1205.0...21
CO/BO: Flying restart vector control status / FlyRest vector st
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1206[0...9]
Automatic restart faults not active / AR fault not act
A_INF, B_INF, R_INF,
Can be changed: T, U
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Functions
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p1207
BI: AR connection following drive object / AR connection DO
A_INF, B_INF, R_INF,
Can be changed: T, U
Calculated: -
Access level: 3
S_INF
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1022
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1208[0...1]
BI: AR modification infeed / AR modification
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1210
Automatic restart mode / AR mode
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
16
0
p1210
Automatic restart mode / AR mode
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
16
0
p1210
Automatic restart mode / AR mode
A_INF, R_INF
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
0
p1210
Automatic restart mode / AR mode
B_INF
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
0
p1210
Automatic restart mode / AR mode
S_INF
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1023
SINAMICS parameters
3.2 SINAMICS parameters
p1211
Automatic restart start attempts / AR start attempts
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
10
3
p1211
Automatic restart start attempts / AR start attempts
A_INF, B_INF, R_INF,
Can be changed: T, U
Calculated: -
Access level: 3
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
10
3
p1212
Automatic restart delay time start attempts / AR t_wait start
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.1 [s]
1000.0 [s]
1.0 [s]
p1212
Automatic restart delay time start attempts / AR t_wait start
A_INF, B_INF, R_INF,
Can be changed: T, U
Calculated: -
Access level: 3
S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.1 [s]
1000.0 [s]
1.0 [s]
p1213[0...1]
Automatic restart monitoring time / AR t_mon
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [s]
10000.0 [s]
0.0 [s]
p1213[0...1]
Automatic restart monitoring time / AR t_mon
A_INF, B_INF, R_INF,
Can be changed: T, U
Calculated: -
Access level: 3
S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [s]
10000.0 [s]
0.0 [s]
Machine data and parameters
1024
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1214.0...15
CO/BO: Automatic restart status / AR status
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r1214.0...15
CO/BO: Automatic restart status / AR status
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1215
Motor holding brake configuration / Brake config
HLA
Can be changed: T
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: 2701, 2707,
2711
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
3
0
p1215
Motor holding brake configuration / Brake config
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: -
Function diagram: 2701, 2707,
2711
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
p1216
Motor holding brake opening time / Brake t_open
HLA
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2701
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0 [ms]
10000 [ms]
100 [ms]
p1216
Motor holding brake opening time / Brake t_open
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2701, 2711
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
10000 [ms]
100 [ms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1025
SINAMICS parameters
3.2 SINAMICS parameters
p1217
Motor holding brake closing time / Brake t_close
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2701, 2711
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
10000 [ms]
100 [ms]
p1218[0...1]
BI: Open motor holding brake / Open brake
SERVO (Ext brake),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Ext brake),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2707
VECTOR (Ext brake),
P-Group: Functions
Unit group: -
Unit selection: -
VECTOR_AC (Ext brake)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1219[0...3]
BI: Immediately close motor holding brake / Close brake
SERVO (Ext brake),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Ext brake),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2707
VECTOR (Ext brake),
P-Group: Functions
Unit group: -
Unit selection: -
VECTOR_AC (Ext brake)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
[0] 0
[1] 0
[2] 0
[3] 1229.9
p1220
CI: Open motor holding brake signal source threshold / Open brake thr
SERVO (Ext brake),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Ext brake),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 2707
VECTOR (Ext brake),
P-Group: Functions
Unit group: -
Unit selection: -
VECTOR_AC (Ext brake)
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1221
Open motor holding brake threshold / Open brake thr
SERVO (Ext brake),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Ext brake),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2707
VECTOR (Ext brake),
P-Group: Functions
Unit group: -
Unit selection: -
VECTOR_AC (Ext brake)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
200.00 [%]
0.00 [%]
Machine data and parameters
1026
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1222
BI: Motor holding brake feedback signal brake closed / Brake fdbk closed
SERVO (Ext brake),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Ext brake),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2711
VECTOR (Ext brake),
P-Group: Functions
Unit group: -
Unit selection: -
VECTOR_AC (Ext brake)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1223
BI: Motor holding brake feedback signal brake open / Brake fdbk open
SERVO (Ext brake),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Ext brake),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2711
VECTOR (Ext brake),
P-Group: Functions
Unit group: -
Unit selection: -
VECTOR_AC (Ext brake)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p1224[0...3]
BI: Close motor holding brake at standstill / Brk close standst
SERVO (Ext brake),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Ext brake),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2704
VECTOR (Ext brake),
P-Group: Functions
Unit group: -
Unit selection: -
VECTOR_AC (Ext brake)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1225
CI: Standstill detection threshold value / Standstill thr
SERVO (Ext brake),
Can be changed: T
Calculated: -
Access level: 2
SERVO_AC (Ext brake),
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 2704
VECTOR (Ext brake),
P-Group: Functions
Unit group: -
Unit selection: -
VECTOR_AC (Ext brake)
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
-
-
63[0]
p1226[0...n]
Standstill detection velocity threshold / v_standst v_thr
HLA
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Functions
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
0.20 [m/min]
p1226[0...n]
Threshold for zero speed detection / n_standst n_thr
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 2701, 2704
P-Group: Functions
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
20.00 [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1027
SINAMICS parameters
3.2 SINAMICS parameters
p1226[0...n]
Standstill detection velocity threshold / v_standst v_thr
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 2701, 2704
P-Group: Functions
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
0.20 [m/min]
p1227
Zero speed detection monitoring time / Standst_id t_mon
HLA
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
300.000 [s]
4.000 [s]
p1227
Zero speed detection monitoring time / n_standst t_mon
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2701, 2704
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
300.000 [s]
4.000 [s]
p1228
Pulse suppression delay time / Pulse suppr t_del
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2701, 2704
VECTOR_AC
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
299.000 [s]
0.000 [s]
r1229.1...11
CO/BO: Motor holding brake status word / Brake ZSW
SERVO (Ext brake),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Ext brake),
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR (Ext brake),
P-Group: Functions
Unit group: -
Unit selection: -
VECTOR_AC (Ext brake)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p1230[0...n]
BI: Armature short-circuit / DC braking activation / ASC/DC brk act
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 7014, 7016,
7017
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
1028
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1231[0...n]
Armature short-circuit / DC braking configuration / ASC/DCBRK config
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: 7014, 7016,
7017
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
14
0
p1232[0...n]
DC braking braking current / DCBRK I_brake
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 7017
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
p1232[0...n]
DC braking braking current / DCBRK I_brake
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 7017
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
p1233[0...n]
DC braking time / DCBRK time
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 7017
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [s]
3600.0 [s]
1.0 [s]
p1234[0...n]
Speed at the start of DC braking / DCBRK n_start
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 7017
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
210000.00 [rpm]
p1234[0...n]
DC braking starting velocity / DCBRK v_start
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 7017
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1300.00 [m/min]
1000.00 [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1029
SINAMICS parameters
3.2 SINAMICS parameters
p1234[0...n]
Speed at the start of DC braking / DCBRK n_start
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 7017
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
40000.00 [rpm]
p1235[0...n]
BI: External armature short-circuit contactor feedback signal / ASC ext feedback
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: ASM, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p1236[0...n]
Ext. armature short-cct. contactor feedback signal monit. time / ASC ext t_mon
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: ASM, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
200 [ms]
p1237[0...n]
External armature short-circuit delay time when opening / ASC ext t_wait
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: ASM, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
200 [ms]
r1238
CO: Armature short-circuit external state / EASC state
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: -
Function diagram: 2610
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
-
r1239.0...13
CO/BO: Armature short-circuit / DC braking status word / ASC/DCBRK ZSW
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
1030
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1240[0...n]
Vdc controller or Vdc monitoring configuration / Vdc ctrl config
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: 3082, 5650
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
9
0
p1240[0...n]
Vdc controller or Vdc monitoring configuration / Vdc ctrl config
VECTOR (F3E, n/M),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E, n/M)
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: 6220
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
0
0
p1240[0...n]
Vdc controller or Vdc monitoring configuration / Vdc ctrl config
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: 6220
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
1
p1241[0...n]
Vdc_max controller switch-in level / Vdc_max on_level
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
100 [%]
118 [%]
118 [%]
p1241
Vdc_max controller switch-in level / Vdc_max on_level
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
70.0 [%]
100.0 [%]
100.0 [%]
r1242
Vdc_max controller switch-in level / Vdc_max on_level
VECTOR (F3E, n/M),
Can be changed: -
Calculated: -
Access level: 8
VECTOR_AC (F3E, n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6220
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1031
SINAMICS parameters
3.2 SINAMICS parameters
r1242
Vdc_max controller switch-in level / Vdc_max on_level
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6220
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p1243[0...n]
Vdc_max controller dynamic factor / Vdc_max dyn_factor
VECTOR (F3E, n/M),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 8
VECTOR_AC (F3E, n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6220
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [%]
10000 [%]
100 [%]
p1243[0...n]
Vdc_max controller dynamic factor / Vdc_max dyn_factor
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6220
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [%]
10000 [%]
100 [%]
p1244[0...n]
DC link voltage threshold upper / Vdc upper thr
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 5650
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
165 [V]
1200 [V]
750 [V]
p1245[0...n]
Vdc_min controller switch-in level (kinetic buffering) / Vdc_min on_level
VECTOR (F3E, n/M),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E, n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
65 [%]
150 [%]
76 [%]
p1245[0...n]
Vdc_min controller switch-in level (kinetic buffering) / Vdc_min on_level
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
65 [%]
150 [%]
76 [%]
Machine data and parameters
1032
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1245
Vdc_min controller switch-in level / Vdc_min on_level
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
100.0 [%]
200.0 [%]
100.0 [%]
r1246
Vdc_min controller switch-in level (kinetic buffering) / Vdc_min on_level
VECTOR (F3E, n/M),
Can be changed: -
Calculated: -
Access level: 8
VECTOR_AC (F3E, n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6220
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r1246
Vdc_min controller switch-in level (kinetic buffering) / Vdc_min on_level
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6220
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p1247[0...n]
Vdc_min controller dynamic factor (kinetic buffering) / Vdc_min dyn_factor
VECTOR (F3E, n/M),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 8
VECTOR_AC (F3E, n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6220
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [%]
10000 [%]
100 [%]
p1247[0...n]
Vdc_min controller dynamic factor (kinetic buffering) / Vdc_min dyn_factor
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 6220
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [%]
10000 [%]
100 [%]
p1248[0...n]
DC link voltage threshold lower / Vdc lower thr
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: 5650
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50 [V]
1000 [V]
285 [V]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1033
SINAMICS parameters
3.2 SINAMICS parameters
p1249[0...n]
Vdc_max controller speed threshold / Vdc_max n_thr
VECTOR (F3E, n/M),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
VECTOR_AC (F3E, n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Functions
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
10.00 [rpm]
p1249[0...n]
Vdc_max controller speed threshold / Vdc_max n_thr
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Functions
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
10.00 [rpm]
p1250[0...n]
Vdc controller proportional gain / Vdc_ctrl Kp
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 5650
P-Group: Functions
Unit group: 19_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [A/V]
100.00 [A/V]
1.00 [A/V]
p1250[0...n]
Vdc controller proportional gain / Vdc_ctrl Kp
VECTOR (F3E, n/M),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E, n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
1.00
p1250[0...n]
Vdc controller proportional gain / Vdc_ctrl Kp
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
1.00
p1250
Vdc controller proportional gain / Vdc_ctrl Kp
A_INF (Line droop ctrl),
Can be changed: T, U
Calculated: -
Access level: 4
R_INF (Line droop ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
100.00
0.00
Machine data and parameters
1034
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p1251[0...n]
Vdc controller integral time / Vdc_ctrl Tn
VECTOR (F3E, n/M),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E, n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6220
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
10000 [ms]
0 [ms]
p1251[0...n]
Vdc controller integral time / Vdc_ctrl Tn
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6220
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
10000 [ms]
0 [ms]
p1252[0...n]
Vdc controller rate time / Vdc_ctrl Tv
VECTOR (F3E, n/M),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E, n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6220
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
0 [ms]
p1252[0...n]
Vdc controller rate time / Vdc_ctrl Tv
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 6220
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
0 [ms]
p1254
Vdc_max controller automatic ON level detection / Vdc_max SenseOnLev
VECTOR (F3E, n/M),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E, n/M)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
1
p1254
Vdc_max controller automatic ON level detection / Vdc_max SenseOnLev
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1035
SINAMICS parameters
3.2 SINAMICS parameters
p1255[0...n]
Vdc_min controller time threshold / Vdc_min t_thr
VECTOR (F3E, n/M),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E, n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
10000.000 [s]
0.000 [s]
p1255[0...n]
Vdc_min controller time threshold / Vdc_min t_thr
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
10000.000 [s]
0.000 [s]
p1256[0...n]
Vdc_min controller response (kinetic buffering) / Vdc_min response
VECTOR (F3E, n/M),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (F3E, n/M)
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1256[0...n]
Vdc_min controller response (kinetic buffering) / Vdc_min response
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p1257[0...n]
Vdc_min controller speed threshold / Vdc_min n_thr
VECTOR (F3E, n/M),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 8
VECTOR_AC (F3E, n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
50.00 [rpm]
p1257[0...n]
Vdc_min controller speed threshold / Vdc_min n_thr
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Functions
Unit group: 3_1
Unit selection: p0505
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
50.00 [rpm]
Machine data and parameters
1036
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r1258
CO: Vdc controller output / Vdc_ctrl output
VECTOR (F3E, n/M),
Can be changed: -
Calculated: -
Access level: 8
VECTOR_AC (F3E, n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6220
P-Group: Functions
Unit group: 6_2
Unit selection: p0505
Not for motor type: REL
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r1258
CO: Vdc controller output / Vdc_ctrl output
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6220
P-Group: Functions
Unit group: 6_2
Unit selection: p0505
Not for motor type: REL
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
p1260
Bypass configuration / Bypass config
SERVO (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
3
0
p1260
Bypass configuration / Bypass config
VECTOR (Tech_ctrl),
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR_AC (Tech_ctrl)
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
r1261.0...13
CO/BO: Bypass control/status word / Bypass STW / ZSW
SERVO (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 8
SERVO_AC (Tech_ctrl)
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r1261.0...12
CO/BO: Bypass control/status word / Bypass STW / ZSW
VECTOR (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 2
VECTOR_AC (Tech_ctrl)
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
1037

 

 

 

 

 

 

 

Content      ..     13      14      15      16     ..