SINUMERIK 840D sl. Service - Configuring Commissioning. Manual (2011-2020) - page 14

 

  Index      Manuals     SINUMERIK 840D sl. Service - Configuring Commissioning. Manual (2011-2020)

 

Search            copyright infringement  

 

   

 

   

 

Content      ..     12      13      14      15     ..

 

 

 

SINUMERIK 840D sl. Service - Configuring Commissioning. Manual (2011-2020) - page 14

 

 

SINAMICS parameters
3.2 SINAMICS parameters
r0481[0...2]
CO: Encoder status word Gn_ZSW / Enc Gn_ZSW
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: -
Function diagram: 4010, 4704,
VECTOR_AC
4730, 4750
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0481
CO: TM41 encoder emulation status word Gn_ZSW / Enc Gn_ZSW
TM41
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 9676
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0481
CO: Encoder status word Gn_ZSW / Enc Gn_ZSW
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 4704, 4730,
4750
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0482[0...2]
CO: Encoder actual position value Gn_XIST1 / Enc Gn_XIST1
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: 4700, 4702,
VECTOR_AC
4704, 4735, 4740, 4750
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0482
CO: TM41 encoder emulation position actual value Gn_XIST1 / Enc Gn_XIST1
TM41
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
900
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0482
CO: Encoder actual position value Gn_XIST1 / Enc Gn_XIST1
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 4704, 4735,
4740, 4750
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0483[0...2]
CO: Encoder actual position value Gn_XIST2 / Enc Gn_XIST2
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: 4704, 4750
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0483
CO: TM41 encoder emulation position actual value Gn_XIST2 / Enc Gn_XIST2
TM41
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0483
CO: Encoder actual position value Gn_XIST2 / Enc Gn_XIST2
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 4704, 4750
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0484[0...2]
CO: Redundant coarse encoder position + CRC / Enc red pos+CRC
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0484
CO: Redundant coarse encoder position + CRC / Enc red pos+CRC
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
901
SINAMICS parameters
3.2 SINAMICS parameters
r0485[0...2]
CO: Measuring gear encoder raw value incremental / Enc raw val incr
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0485
CO: Measuring gear encoder raw value incremental / Enc raw val incr
ENC
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0486[0...2]
CO: Measuring gear encoder raw value absolute / Enc raw val abs
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0486
CO: Measuring gear encoder raw value absolute / Enc raw val abs
ENC
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0487[0...2]
Diagnostic encoder control word Gn_STW / Enc Gn_STW
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: -
Function diagram: 4700, 4704,
VECTOR_AC
4720, 4740
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0487
Diagnostic encoder control word Gn_STW / Enc Gn_STW
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 4700, 4704,
4720, 4740
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
902
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0488[0...2]
Measuring probe 1 input terminal / Meas probe 1 inp
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: -
Function diagram: 4740
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
8
0
p0488[0...2]
Measuring probe 1 input terminal / Meas probe 1 inp
SERVO (Dig IO)
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 4740
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
51
0
p0488
Measuring probe 1 input terminal / Meas probe 1 inp
ENC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 4740
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
8
0
p0489[0...2]
Measuring probe 2 input terminal / Meas probe 2 inp
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: -
Function diagram: 4740
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
8
0
p0489[0...2]
Measuring probe 2 input terminal / Meas probe 2 inp
SERVO (Dig IO)
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 4740
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
51
0
p0489
Measuring probe 2 input terminal / Meas probe 2 inp
ENC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 4740
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
8
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
903
SINAMICS parameters
3.2 SINAMICS parameters
p0490
Invert measuring probe or equivalent zero mark / Pr or ZM_equiv inv
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: 4740
CU_S120_DP,
P-Group: Encoder
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p0491
Motor encoder fault response ENCODER / Fault resp ENCODER
HLA, TM41
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
0
p0491
Motor encoder fault response ENCODER / Fault resp ENCODER
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
0
p0491
Motor encoder fault response ENCODER / Fault resp ENCODER
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
0
p0492
Square-wave encoder max. velocity difference per sampling cycle / v_dif max/samp_cyc
HLA
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
210000.00 [m/min]
0.00 [m/min]
p0492
Square-wave encoder maximum speed difference per sampling cycle / n_dif max/
samp_cyc
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
0.00 [rpm]
Machine data and parameters
904
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0492
Square-wave encoder max. velocity difference per sampling cycle / v_dif max/samp_cyc
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
0.00 [m/min]
p0492
Maximum speed difference per sampling cycle / n_dif max/samp_cyc
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
0.00 [rpm]
p0492
Square-wave encoder maximum speed difference per sampling cycle / n_dif max/
samp_cyc
ENC
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
0.00 [rpm]
p0492
Square-wave encoder max. velocity difference per sampling cycle / v_dif max/samp_cyc
ENC (Lin_enc)
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [m/min]
1000.00 [m/min]
0.00 [m/min]
p0493[0...n]
Zero mark selection input terminal / ZM_sel inp_term
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
8
0
p0493[0...n]
Zero mark selection input terminal / ZM_sel inp_term
SERVO (Dig IO)
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
51
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
905
SINAMICS parameters
3.2 SINAMICS parameters
p0493
Zero mark selection input terminal / ZM_sel inp_term
ENC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
211
0
p0494[0...n]
Equivalent zero mark input terminal / ZM_equiv inp_term
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
8
0
p0494[0...n]
Equivalent zero mark input terminal / ZM_equiv inp_term
SERVO (Dig IO)
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
51
0
p0495[0...2]
Equivalent zero mark input terminal / ZM_equiv input
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: -
Function diagram: 4735
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
8
0
p0495[0...2]
Equivalent zero mark input terminal / ZM_equiv input
SERVO (Dig IO)
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 4735
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
51
0
p0495
Equivalent zero mark input terminal / ZM_equiv input
ENC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 4735
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
8
0
Machine data and parameters
906
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0496[0...2]
Encoder diagnostic signal selection / Enc diag select
HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
86
0
p0496
Encoder diagnostic signal selection / Enc diag select
ENC
Can be changed: T, U
Calculated: -
Access level: 4
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
86
0
r0497[0...2]
CO: Encoder diagnostic signal double word / Enc diag DW
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0497
Encoder diagnostic signal double word / Enc diag DW
ENC
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0498[0...2]
CO: Encoder diagnostic signal low word / Enc diag low word
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0498
Encoder diagnostic signal low word / Enc diag low word
ENC
Can be changed: -
Calculated: -
Access level: 4
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
907
SINAMICS parameters
3.2 SINAMICS parameters
r0499[0...2]
CO: Encoder diagnostic signal high word / Enc diag high word
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0499
Encoder diagnostic signal high word / Enc diag high word
ENC
Can be changed: -
Calculated: -
Access level: 4
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0500
Technology application / Tec application
SERVO, SERVO_AC
Can be changed: C2(1), T
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Applications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
100
103
100
p0500
Technology application / Tec application
VECTOR, VECTOR_AC
Can be changed: C2(1), T
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Applications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
1
p0505
Selecting the system of units / Unit sys select
A_INF, B_INF, ENC,
Can be changed: C2(5)
Calculated: -
Access level: 1
HLA, R_INF, S_INF,
Data type: Integer16
Dynamic index: -
Function diagram: -
SERVO, SERVO_AC,
P-Group: Applications
Unit group: -
Unit selection: -
TM41, VECTOR,
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
4
1
p0514[0...9]
Scaling-specific reference values / Scal spec ref val
A_INF, B_INF, HLA,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
R_INF, S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Communications
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000001
10000000.000000
1.000000
Machine data and parameters
908
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0515[0...19]
Scaling specific parameters referred to p0514[0] / Scal spec p514[0]
A_INF, B_INF, HLA,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Communications
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
0
p0516[0...19]
Scaling specific parameters referred to p0514[1] / Scal spec p514[1]
A_INF, B_INF, HLA,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Communications
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
0
p0517[0...19]
Scaling specific parameters referred to p0514[2] / Scal spec p514[2]
A_INF, B_INF, HLA,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Communications
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
0
p0518[0...19]
Scaling specific parameters referred to p0514[3] / Scal spec p514[3]
A_INF, B_INF, HLA,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Communications
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
0
p0519[0...19]
Scaling specific parameters referred to p0514[4] / Scal spec p514[4]
A_INF, B_INF, HLA,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Communications
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
0
p0520[0...19]
Scaling specific parameters referred to p0514[5] / Scal spec p514[5]
A_INF, B_INF, HLA,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Communications
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
909
SINAMICS parameters
3.2 SINAMICS parameters
p0521[0...19]
Scaling specific parameters referred to p0514[6] / Scal spec p514[6]
A_INF, B_INF, HLA,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Communications
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
0
p0522[0...19]
Scaling specific parameters referred to p0514[7] / Scal spec p514[7]
A_INF, B_INF, HLA,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Communications
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
0
p0523[0...19]
Scaling specific parameters referred to p0514[8] / Scal spec p514[8]
A_INF, B_INF, HLA,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Communications
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
0
p0524[0...19]
Scaling specific parameters referred to p0514[9] / Scal spec p514[9]
A_INF, B_INF, HLA,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Communications
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
0
p0528
Controller gain system of units / Ctrl_gain unit_sys
ENC, HLA, SERVO,
Can be changed: C2(5)
Calculated: -
Access level: 4
SERVO_AC, TM41
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Applications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0528
Controller gain system of units / Ctrl_gain unit_sys
VECTOR, VECTOR_AC
Can be changed: C2(5)
Calculated: -
Access level: 4
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Applications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
1
Machine data and parameters
910
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0528
Controller gain system of units / Ctrl_gain unit_sys
A_INF, B_INF, R_INF,
Can be changed: C2(5)
Calculated: -
Access level: 8
S_INF
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Applications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
1
0
p0530[0...n]
Bearing version selection / Bearing vers sel
SERVO, SERVO_AC,
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
104
0
p0531[0...n]
Bearing code number selection / Bearing codeNo sel
SERVO, SERVO_AC,
Can be changed: C2(3)
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p0532[0...n]
Bearing maximum speed / Bearing n_max
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [rpm]
210000.0 [rpm]
0.0 [rpm]
p0532[0...n]
Bearing maximum velocity / Bearing v_max
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [m/min]
1300.0 [m/min]
0.0 [m/min]
p0532[0...n]
Bearing maximum speed / Bearing n_max
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [rpm]
210000.0 [rpm]
0.0 [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
911
SINAMICS parameters
3.2 SINAMICS parameters
p0541[0...n]
Load gearbox code number / Load grbx code no
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
1
p0541[0...n]
Load gearbox code number / Load grbx code no
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: Unsigned32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
1
p0541[0...n]
Load gearbox code number / Load grbx code no
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: Unsigned32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
1
p0542[0...n]
Load gearbox maximum speed / Load grbx n_max
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [rpm]
210000.0 [rpm]
0.0 [rpm]
p0542[0...n]
Load gearbox maximum speed / Load grbx n_max
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [m/min]
210000.0 [m/min]
0.0 [m/min]
p0542[0...n]
Load gearbox maximum speed / Load grbx n_max
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [rpm]
210000.0 [rpm]
0.0 [rpm]
Machine data and parameters
912
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0543[0...n]
Load gearbox maximum torque / Load grbx M_max
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 7_4
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
1000000.00 [Nm]
0.00 [Nm]
p0543[0...n]
Load gearbox maximum torque / Load grbx M_max
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 8_4
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [N]
1000000.00 [N]
0.00 [N]
p0543[0...n]
Load gearbox maximum torque / Load grbx M_max
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 7_4
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
1000000.00 [Nm]
0.00 [Nm]
p0544[0...n]
Load gearbox overall ratio numerator / Load grbx ratio N
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: Integer32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2147483647
0
p0544[0...n]
Load gearbox overall ratio numerator / Load grbx ratio N
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: Integer32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2147483647
0
p0544[0...n]
Load gearbox overall ratio numerator / Load grbx ratio N
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: Integer32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2147483647
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
913
SINAMICS parameters
3.2 SINAMICS parameters
p0545[0...n]
Load gearbox overall ratio denominator / Load grbx ratio D
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: Integer32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2147483647
0
p0545[0...n]
Load gearbox overall ratio denominator / Load grbx ratio D
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: Integer32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2147483647
0
p0545[0...n]
Load gearbox overall ratio denominator / Load grbx ratio D
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: Integer32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2147483647
0
p0546[0...n]
Load gearbox direction of rotation inversion / Load grbx dir inv
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: Integer32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2147483647
0
p0546[0...n]
Load gearbox direction of rotation inversion / Load grbx dir inv
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: Integer32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2147483647
0
p0546[0...n]
Load gearbox direction of rotation inversion / Load grbx dir inv
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: Integer32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2147483647
0
Machine data and parameters
914
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0547[0...n]
Load gearbox moment of inertia / Load grbx m_inert
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 25_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000000 [kgm²]
100000.000000 [kgm²]
0.000000 [kgm²]
p0547[0...n]
Load gearbox moment of inertia / Load grbx m_inert
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 27_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000000 [kg]
100000.000000 [kg]
0.000000 [kg]
p0547[0...n]
Load gearbox moment of inertia / Load grbx m_inert
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 25_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000000 [kgm²]
100000.000000 [kgm²]
0.000000 [kgm²]
p0550[0...n]
Brake version / Brake version
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p0550[0...n]
Brake version / Brake version
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p0550[0...n]
Brake version / Brake version
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
915
SINAMICS parameters
3.2 SINAMICS parameters
p0551[0...n]
Brake code number / Brake code no
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
1
p0551[0...n]
Brake code number / Brake code no
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: Unsigned32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
1
p0551[0...n]
Brake code number / Brake code no
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: Unsigned32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
1
p0552[0...n]
Maximum brake speed / Brake n_max
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [rpm]
210000.0 [rpm]
0.0 [rpm]
p0552[0...n]
Maximum brake speed / Brake n_max
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [m/min]
210000.0 [m/min]
0.0 [m/min]
p0552[0...n]
Maximum brake speed / Brake n_max
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [rpm]
210000.0 [rpm]
0.0 [rpm]
Machine data and parameters
916
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0553[0...n]
Brake holding torque / Brake M_hold
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 7_4
Unit selection: p0100
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
1000000.00 [Nm]
0.00 [Nm]
p0553[0...n]
Brake holding torque / Brake M_hold
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 8_4
Unit selection: p0100
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [N]
1000000.00 [N]
0.00 [N]
p0553[0...n]
Brake holding torque / Brake M_hold
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 7_4
Unit selection: p0100
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
1000000.00 [Nm]
0.00 [Nm]
p0554[0...n]
Brake moment of inertia / Brake m_inert
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 25_1
Unit selection: p0100
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kgm²]
- [kgm²]
- [kgm²]
p0554[0...n]
Brake moment of inertia / Brake m_inert
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 27_1
Unit selection: p0100
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kg]
- [kg]
- [kg]
p0554[0...n]
Brake moment of inertia / Brake m_inert
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 25_1
Unit selection: p0100
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000000 [kgm²]
100000.000000 [kgm²]
0.000000 [kgm²]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
917
SINAMICS parameters
3.2 SINAMICS parameters
r0555[0...n]
Brake voltage overexcitation / Brake U_overex
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0555[0...n]
Brake voltage overexcitation / Brake U_overex
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0556[0...n]
Brake voltage opened / Brake U opened
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0556[0...n]
Brake voltage opened / Brake U opened
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0557[0...n]
Open brake overexcitation time / Brake t_overex
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
r0557[0...n]
Open brake overexcitation time / Brake t_overex
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
Machine data and parameters
918
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0558[0...n]
Brake configuration / Brake config
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0000 bin
r0565[0...15]
CO: Probe time stamp / Probe t_stamp
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0566[0...3]
CO: Probe time stamp reference / Probe t_stamp name
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0567
CO: Probe diagnostics word / Probe diag_word
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0570
Inhibit list values effective number / Inhib list no
TM41
Can be changed: T, U
Calculated: -
Access level: 8
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Applications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
50
0
p0570
Inhibit list values effective number / Inhib list no
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Applications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
50
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
919
SINAMICS parameters
3.2 SINAMICS parameters
p0571[0...49]
Inhibit list motor/closed-loop control parameter calculation / Inhib list calc
TM41
Can be changed: T, U
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Applications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
2142
0
p0571[0...49]
Inhibit list motor/closed-loop control parameter calculation / Inhib list calc
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Applications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2142
0
p0571[0...49]
Inhibit list motor/closed-loop control parameter calculation / Inhib list calc
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Applications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2142
0
p0572[0...n]
Activate/deactivate inhibit list / Inh_list act/deact
TM41
Can be changed: T, U
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Applications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
1
0
p0572[0...n]
Activate/deactivate inhibit list / Inh_list act/deact
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Applications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0573
Inhibit automatic reference value calculation / Inhibit calc
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 2
R_INF, S_INF, SERVO,
Data type: Integer16
Dynamic index: -
Function diagram: -
SERVO_AC, TM41,
P-Group: Applications
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
920
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0578[0...n]
Calculate technology-dependent parameters / Calc tec par
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Applications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
r0579
List of drive objects number / List of DO qty
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Data sets
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
25
25
-
p0580
Measuring probe input terminal / MT input terminal
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
8
0
p0581
Measuring probe edge / MT edge
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0582
Measuring probe pulses per revolution / MT pulses per rev
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
12
1
p0583
Measuring probe maximum measuring time / MT t_meas max
HLA, SERVO, SERVO_AC Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.040 [s]
10.000 [s]
10.000 [s]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
921
SINAMICS parameters
3.2 SINAMICS parameters
r0586
CO: Measuring probe speed actual value / MT n_act
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0586
CO: Measuring probe velocity actual value / MT v_act
HLA, SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r0587
CO: Measuring probe measuring time measured / MT t_meas measured
HLA, SERVO, SERVO_AC Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0588
CO: Measuring probe pulse counter / MT pulse counter
HLA, SERVO, SERVO_AC Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0589
Measuring probe delay time / MT t_delay
HLA, SERVO, SERVO_AC Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0595
Technological unit selection / Tec unit sel
SERVO (Tech_ctrl),
Can be changed: C2(5)
Calculated: -
Access level: 1
SERVO_AC (Tech_ctrl),
Data type: Integer16
Dynamic index: -
Function diagram: -
VECTOR (Tech_ctrl),
P-Group: Applications
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
32
1
Machine data and parameters
922
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0596
Technological unit reference quantity / Tec unit ref qty
SERVO (Tech_ctrl),
Can be changed: T
Calculated: -
Access level: 1
SERVO_AC (Tech_ctrl),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR (Tech_ctrl),
P-Group: -
Unit group: -
Unit selection: -
VECTOR_AC (Tech_ctrl)
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.01
340.28235E36
1.00
p0600[0...n]
Motor temperature sensor for monitoring / Mot temp_sensor
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 2
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
21
1
p0600[0...n]
Motor temperature sensor for monitoring / Mot temp_sensor
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 2
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
21
0
p0601[0...n]
Motor temperature sensor type / Mot_temp_sens type
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
11
2
p0601
Temperature sensor, sensor type / Temp_sens type
A_INF, B_INF, R_INF,
Can be changed: T, U
Calculated: -
Access level: 2
S_INF
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
0
p0602
Par_connection power unit number, temperature sensor / PU_no temp_sensor
VECTOR (Parallel),
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR_AC (Parallel)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
10
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
923
SINAMICS parameters
3.2 SINAMICS parameters
p0603
CI: Motor temperature signal source / Mot temp s_s
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0604[0...n]
Mot_temp_mod 2: sensor alarm threshold / Mod 2: sens A_thr
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8016
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [°C]
200.0 [°C]
120.0 [°C]
p0604[0...n]
Mot_temp_mod 2: sensor alarm threshold / Mod 2: sens A_thr
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8016
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [°C]
200.0 [°C]
130.0 [°C]
p0605[0...n]
Mot_temp_mod 1/2 sensor threshold and temperature value / Mod 1/2 sens thr_T
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8016, 8017
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [°C]
240.0 [°C]
145.0 [°C]
p0606[0...n]
Mot_temp_mod 2: sensor timer / Mod 2:sens timer
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
600.000 [s]
240.000 [s]
p0606[0...n]
Mot_temp_mod 2: sensor timer / Mod 2:sens timer
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
600.000 [s]
0.000 [s]
Machine data and parameters
924
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0607[0...n]
Temperature sensor fault timer / Sensor fault time
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
600.000 [s]
0.100 [s]
p0608[0...3]
CI: Motor temperature signal source 2 / Mot_temp s_s 2
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0609[0...3]
CI: Motor temperature signal source 3 / Mot_temp s_s 3
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 8016
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0610[0...n]
Motor overtemperature response / Mot temp response
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: 8016, 8017,
8018, 8019
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
12
12
p0611[0...n]
I2t motor model thermal time constant / I2t MotMod Tc
SERVO, SERVO_AC,
Can be changed: C2(1), T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8017
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [s]
20000 [s]
0 [s]
p0612[0...n]
Mot_temp_mod activation / Mot_temp_mod act
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: 8017, 8018,
8019
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0010 0000 0010 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
925
SINAMICS parameters
3.2 SINAMICS parameters
p0613[0...n]
Mot_temp_mod 1/3 ambient temperature / Mod 1/3 amb_temp
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8017, 8019
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-40 [°C]
100 [°C]
40 [°C]
p0613[0...n]
Mot_temp_mod 1/3 ambient temperature / Mod 1/3 amb_temp
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8017, 8019
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-40 [°C]
100 [°C]
20 [°C]
p0614[0...n]
Thermal resistance adaptation reduction factor / Therm R_adapt red
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [%]
100 [%]
30 [%]
p0615[0...n]
Mot_temp_mod 1 (I2t) fault threshold / I2t F thr
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8017
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [°C]
220.0 [°C]
180.0 [°C]
p0616[0...n]
Motor overtemperature alarm threshold 1 / Mot temp alarm 1
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8016
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [°C]
200.0 [°C]
195.0 [°C]
p0616[0...n]
Motor overtemperature alarm threshold 1 / Mot temp alarm 1
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8016
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [°C]
200.0 [°C]
130.0 [°C]
Machine data and parameters
926
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0617[0...n]
Stator thermally relevant iron component / Stat therm iron
SERVO, SERVO_AC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8018
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
100.0 [%]
40.0 [%]
p0617[0...n]
Stator thermally relevant iron component / Stat therm iron
VECTOR, VECTOR_AC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8018
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
100.0 [%]
40.0 [%]
p0618[0...n]
Stator thermally relevant copper component / Stat therm copper
SERVO, SERVO_AC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8018
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
100.0 [%]
15.0 [%]
p0618[0...n]
Stator thermally relevant copper component / Stat therm copper
VECTOR, VECTOR_AC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8018
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
100.0 [%]
15.0 [%]
p0619[0...n]
Rotor thermally relevant weight / Rotor therm weight
SERVO, SERVO_AC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8018
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
100.0 [%]
20.0 [%]
p0619[0...n]
Rotor thermally relevant weight / Rotor therm weight
VECTOR, VECTOR_AC
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8018
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
100.0 [%]
20.0 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
927
SINAMICS parameters
3.2 SINAMICS parameters
p0620[0...n]
Thermal adaptation, stator and rotor resistance / Mot therm_adpt R
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
2
p0620[0...n]
Thermal adaptation, stator and rotor resistance / Mot therm_adpt R
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 2
Data type: Integer16
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
1
p0621[0...n]
Identification stator resistance after restart / ID rst restart
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 2
VECTOR_AC (n/M)
Data type: Integer16
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
p0622[0...n]
Motor excitation time for Rs_ident after switching on again / t_excit Rs_id
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
20.000 [s]
0.000 [s]
r0623
Rs identification stator resistance after switch on again / Rs-id Rs aft sw-on
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor identification
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
p0624[0...n]
Motor temperature offset PT100 / Mot T_offset PT100
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8016
P-Group: Motor
Unit group: 21_2
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100.0 [K]
100.0 [K]
0.0 [K]
Machine data and parameters
928
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0625[0...n]
Motor ambient temperature during commissioning / Mot amb_temp com
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8017, 8018
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-40 [°C]
80 [°C]
20 [°C]
p0626[0...n]
Motor overtemperature, stator core / Mot T_over core
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8018
P-Group: Motor
Unit group: 21_2
Unit selection: p0505
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10 [K]
200 [K]
50 [K]
p0627[0...n]
Motor overtemperature, stator winding / Mot T_over stator
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8017, 8018
P-Group: Motor
Unit group: 21_2
Unit selection: p0505
Not for motor type: SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
15 [K]
200 [K]
80 [K]
p0628[0...n]
Motor overtemperature rotor / Mot T_over rotor
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8018
P-Group: Motor
Unit group: 21_2
Unit selection: p0505
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
20 [K]
200 [K]
100 [K]
p0629[0...n]
Stator resistance reference / R_stator ref
VECTOR (n/M),
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [ohm]
2000.00000 [ohm]
0.00000 [ohm]
r0630[0...n]
Mot_temp_mod ambient temperature / Mod T_ambient
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 4
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8018
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: SESM, REL
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
929
SINAMICS parameters
3.2 SINAMICS parameters
r0631[0...n]
Mot_temp_mod stator iron temperature / Mod T_stator
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 4
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8018, 8019
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: SESM, REL
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r0632[0...n]
Mot_temp_mod stator winding temperature / Mod T_winding
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8017, 8018,
8019
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: SESM, REL
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r0633[0...n]
Mot_temp_mod rotor temperature / Mod rotor temp
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 4
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8018, 8019
P-Group: Motor
Unit group: 21_1
Unit selection: p0505
Not for motor type: SESM, REL
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
p0634[0...n]
Q flux flux constant unsaturated / PSIQ KPSI UNSAT
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.000 [Vsrms]
100.000 [Vsrms]
0.000 [Vsrms]
p0634[0...n]
Q flux flux constant unsaturated / PSIQ KPSI UNSAT
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [Vsrms]
100.000 [Vsrms]
0.000 [Vsrms]
p0635[0...n]
Q flux quadrature axis current constant unsaturated / PSIQ KIQ UNSAT
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
Machine data and parameters
930
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0635[0...n]
Q flux quadrature axis current constant unsaturated / PSIQ KIQ UNSAT
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
p0636[0...n]
Q flux direct axis current constant unsaturated / PSIQ KID UNSAT
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
p0636[0...n]
Q flux direct axis current constant unsaturated / PSIQ KID UNSAT
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
p0637[0...n]
Q flux flux gradient saturated / PSIQ Grad SAT
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [mH]
10000.00 [mH]
0.00 [mH]
p0637[0...n]
Q flux flux gradient saturated / PSIQ Grad SAT
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [mH]
10000.00 [mH]
0.00 [mH]
p0638[0...n]
Removed /
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [mH]
340.28235E36 [mH]
0.00000 [mH]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
931
SINAMICS parameters
3.2 SINAMICS parameters
p0639[0...n]
Removed /
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [mH]
340.28235E36 [mH]
0.00000 [mH]
p0640[0...n]
Current limit / Current limit
SERVO, SERVO_AC,
Can be changed: C2(1), T, U
Calculated: CALC_MOD_ALL
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 5722, 6640
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
p0641[0...n]
CI: Current limit scaling signal source / I_lim scal s_s
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 6300, 6640
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p0642[0...n]
Encoderless operation current reduction / Encoderl op I_red
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
100.00 [%]
100.00 [%]
p0643[0...n]
Overvoltage protection for synchronous motors / U_over_protect
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0643[0...n]
Overvoltage protection for synchronous motors / U_over_protect
VECTOR (n/M),
Can be changed: C2(3)
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Integer16
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
932
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0644[0...n]
Current limit excitation induction motor / Imax excit ASM
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.0 [%]
300.0 [%]
300.0 [%]
p0645[0...n]
Motor kT characteristic kT1 / Mot kT char kT1
SERVO (Ext M_ctrl, Lin),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Ext M_ctrl,
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
Lin)
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [N/Arms]
200.000 [N/Arms]
0.000 [N/Arms]
p0645[0...n]
Motor kT characteristic kT1 / Mot kT char kT1
SERVO (Ext M_ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Ext M_ctrl)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [Nm/A]
200.000 [Nm/A]
0.000 [Nm/A]
p0646[0...n]
Motor kT characteristic kT3 / Mot kT char kT3
SERVO (Ext M_ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Ext M_ctrl)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0647[0...n]
Motor kT characteristic kT5 / Mot kT char kT5
SERVO (Ext M_ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Ext M_ctrl)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0648[0...n]
Motor kT characteristic kT7 / Mot kT char kT7
SERVO (Ext M_ctrl),
Can be changed: T, U
Calculated: -
Access level: 1
SERVO_AC (Ext M_ctrl)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
933
SINAMICS parameters
3.2 SINAMICS parameters
p0650[0...n]
Actual motor operating hours / Mot t_op act
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: MDS, p0130
Function diagram: -
VECTOR_AC
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [h]
4294967295 [h]
0 [h]
p0651[0...n]
Motor operating hours maintenance interval / Mot t_op maint
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: MDS, p0130
Function diagram: -
VECTOR_AC
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [h]
150000 [h]
0 [h]
p0652[0...n]
Motor stator resistance scaling / Mot R_stator scal
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
p0652[0...n]
Motor stator resistance scaling / Mot R_stator scal
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
p0653[0...n]
Motor stator leakage inductance scaling / Mot L_S_leak scal
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
p0653[0...n]
Motor stator leakage inductance scaling / Mot L_S_leak scal
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
Machine data and parameters
934
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0655[0...n]
Motor magnetizing inductance d axis saturated scaling / Mot L_m d sat scal
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
p0655[0...n]
Motor magnetizing inductance d axis saturated scaling / Mot L_m d sat scal
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
p0656[0...n]
Motor magnetizing inductance q axis saturated scaling / Mot L_m q sat scal
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
p0656[0...n]
Motor magnetizing inductance q axis saturated scaling / Mot L_m q sat scal
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
p0657[0...n]
Motor damping inductance d axis scaling / Mot L_damp d scal
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
p0657[0...n]
Motor damping inductance d axis scaling / Mot L_damp d scal
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
935
SINAMICS parameters
3.2 SINAMICS parameters
p0658[0...n]
Motor damping inductance q axis scaling / Mot L_damp q scal
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
p0658[0...n]
Motor damping inductance q axis scaling / Mot L_damp q scal
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
p0659[0...n]
Motor damping resistance d axis scaling / Mot R_damp d scal
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
p0659[0...n]
Motor damping resistance d axis scaling / Mot R_damp d scal
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
p0660[0...n]
Motor damping resistance q axis scaling / Mot R_damp q scal
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
p0660[0...n]
Motor damping resistance q axis scaling / Mot R_damp q scal
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
300.0 [%]
100.0 [%]
Machine data and parameters
936
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0680[0...7]
Central measuring probe input terminal / Cen meas inp
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Encoder
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
8
0
p0681
BI: Central measuring probe synchronizing signal signal source / Cen meas sync_sig
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Commands
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0682
CI: Central measuring probe control word signal source / Cen meas STW s_s
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0684
Central measuring probe evaluation technique / Cen meas eval_tech
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Encoder
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
16
0
r0685
Central measuring probe control word display / Cen meas STW disp
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Commands
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0686[0...7]
CO: Central measuring probe measuring time rising edge / CenMeas t_meas 0/1
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
937
SINAMICS parameters
3.2 SINAMICS parameters
r0687[0...7]
CO: Central measuring probe measuring time falling edge / CenMeas t_meas 1/0
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0688
CO: Central measuring probe status word display / Cen meas ZSW disp
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0690[0...n]
Brushless excitation rated current / BLE I_rated
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [A]
1000.00 [A]
0.00 [A]
p0691[0...n]
Reverse field excitation correction factor / RFE correction
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10 [%]
1000 [%]
100 [%]
p0692[0...n]
Reverse field excitation iron resistance / RFE iron R
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100000.00000 [ohm]
100000.00000 [ohm]
0.00000 [ohm]
p0693[0...n]
Brushless excitation inductance d-axis saturated / BLE L_d sat
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00000 [mH]
1000.00000 [mH]
0.00000 [mH]
Machine data and parameters
938
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0694[0...n]
Reverse field excitation leakage inductance / RFE L_leak
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10.00000 [mH]
10.00000 [mH]
0.00000 [mH]
p0696[0...n]
Brushless excitation ratio / BLE ratio
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
1000.000
0.000
p0697[0...n]
Brushless excitation number of pole pairs / BLE PolePair no
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: Unsigned32
Dynamic index: MDS, p0130
Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
20
0
p0698[0...n]
Brushless excitation, excitation resistance / BLE exc_R
VECTOR (n/M),
Can be changed: T, U
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100.00000 [ohm]
100.00000 [ohm]
0.00000 [ohm]
p0699[0...n]
Excitation configuration / Exc config
VECTOR (n/M),
Can be changed: C2(1, 3)
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
20
0
p0700
Macro Binector Input (BI) / Macro BI
CU_S_AC_DP,
Can be changed: C2(1), T
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Commands
Unit group: -
Unit selection: -
CU_S120_PN, TB30,
TM15DI_DO, TM31
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
999999
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
939
SINAMICS parameters
3.2 SINAMICS parameters
p0700[0...n]
Macro Binector Input (BI) / Macro BI
A_INF, B_INF, HLA,
Can be changed: C2(1), T
Calculated: -
Access level: 1
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: CDS, p0170 Function diagram: -
SERVO_AC, VECTOR,
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
999999
0
r0721
CU digital inputs terminal actual value / CU DI term ActV
CU_S120_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S120_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2119, 2120,
2121, 2130, 2131, 2132, 2133
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0721
CU digital inputs terminal actual value / CU DI term ActV
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2019, 2020,
2021, 2030, 2031, 2032, 2033
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0722.0...21
CO/BO: CU digital inputs status / CU DI status
CU_S120_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S120_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2119, 2120,
2121, 2130, 2131, 2132, 2133
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0722.0...22
CO/BO: CU digital inputs status / CU DI status
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2019, 2020,
2021, 2030, 2031, 2032, 2033
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
940
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0723.0...21
CO/BO: CU digital inputs status inverted / CU DI status inv
CU_S120_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S120_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2119, 2120,
2121, 2130, 2131, 2132, 2133
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0723.0...22
CO/BO: CU digital inputs status inverted / CU DI status inv
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2019, 2020,
2021, 2030, 2031, 2032, 2033
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0728
CU set input or output / CU DI or DO
CU_S120_DP,
Can be changed: T
Calculated: -
Access level: 1
CU_S120_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2119, 2030,
2031, 2130, 2131, 2132, 2133
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p0728
CU set input or output / CU DI or DO
CU_S_AC_DP,
Can be changed: T
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2019, 2030,
2031, 2032, 2033
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
r0729
CU digital outputs access authority / CU DO acc_auth
CU_S120_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S120_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2030, 2031,
2130, 2131, 2132, 2133
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
941
SINAMICS parameters
3.2 SINAMICS parameters
r0729
CU digital outputs access authority / CU DO acc_auth
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2030, 2031,
2032, 2033
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0738
BI: CU signal source for terminal DI/DO 8 / CU s_s DI/DO 8
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S120_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2119, 2130
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0738
BI: CU signal source for terminal DI/DO 8 / CU s_s DI/DO 8
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2019, 2030
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0739
BI: CU signal source for terminal DI/DO 9 / CU s_s DI/DO 9
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S120_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2130
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0739
BI: CU signal source for terminal DI/DO 9 / CU s_s DI/DO 9
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2030
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0740
BI: CU signal source for terminal DI/DO 10 / CU s_s DI/DO 10
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S120_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2131
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
942
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0740
BI: CU signal source for terminal DI/DO 10 / CU s_s DI/DO 10
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2031
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0741
BI: CU signal source for terminal DI/DO 11 / CU s_s DI/DO 11
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S120_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2119, 2131
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0741
BI: CU signal source for terminal DI/DO 11 / CU s_s DI/DO 11
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2019, 2031
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0742
BI: CU signal source for terminal DI/DO 12 / CU s_s DI/DO 12
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S120_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2119, 2132
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0742
BI: CU signal source for terminal DI/DO 12 / CU s_s DI/DO 12
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2019, 2032
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0743
BI: CU signal source for terminal DI/DO 13 / CU s_s DI/DO 13
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S120_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2132
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
943
SINAMICS parameters
3.2 SINAMICS parameters
p0743
BI: CU signal source for terminal DI/DO 13 / CU s_s DI/DO 13
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2032
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0744
BI: CU signal source for terminal DI/DO 14 / CU s_s DI/DO 14
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S120_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2133
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0744
BI: CU signal source for terminal DI/DO 14 / CU s_s DI/DO 14
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2033
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0745
BI: CU signal source for terminal DI/DO 15 / CU s_s DI/DO 15
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S120_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2119, 2133
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0745
BI: CU signal source for terminal DI/DO 15 / CU s_s DI/DO 15
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2019, 2033
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0746
BI: CU signal source for terminal DO 16 / CU s_s DO 16
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2019, 2038
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
944
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0746
BI: CU signal source for terminal DO 16 / CU s_s DO 16
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2019, 2038
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r0747
CU digital outputs status / CU DO status
CU_S120_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S120_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2130, 2131,
2132, 2133
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0747
CU digital outputs status / CU DO status
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2030, 2031,
2032, 2033, 2038
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0748
CU invert digital outputs / CU DO inv
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S120_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2030, 2031,
2130, 2131, 2132, 2133
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 bin
p0748
CU invert digital outputs / CU DO inv
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2030, 2031,
2032, 2033, 2038
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
945
SINAMICS parameters
3.2 SINAMICS parameters
r0752[0]
CO: CU analog input input voltage/current actual / CU AI U_input act
CU_S120_DP,
Can be changed: -
Calculated: -
Access level: 9
CU_S120_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r0752[0]
CO: CU analog input input voltage/current actual / CU AI U_input act
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0753[0]
CU analog input smoothing time constant / CU AI Tc_smth
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.0 [ms]
1000.0 [ms]
0.0 [ms]
p0753[0]
CU analog input smoothing time constant / CU AI Tc_smth
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
1000.0 [ms]
0.0 [ms]
r0755[0]
CO: CU analog input actual value in percent / CU AI val in %
CU_S120_DP,
Can be changed: -
Calculated: -
Access level: 9
CU_S120_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9549, 9566
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 0
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0755[0]
CO: CU analog input actual value in percent / CU AI val in %
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2019, 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
Machine data and parameters
946
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0756[0]
CU analog input type / CU AI type
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
5
4
p0756[0]
CU analog input type / CU AI type
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 1
CU_S_AC_PN
Data type: Integer16
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
5
4
p0757[0]
CU analog input characteristic value x1 / CU AI char x1
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-20.000
20.000
0.000
p0757[0]
CU analog input characteristic value x1 / CU AI char x1
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000
20.000
0.000
p0758[0]
CU analog input characteristic value y1 / CU AI char y1
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-1000.00 [%]
1000.00 [%]
0.00 [%]
p0758[0]
CU analog input characteristic value y1 / CU AI char y1
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [%]
1000.00 [%]
0.00 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
947
SINAMICS parameters
3.2 SINAMICS parameters
p0759[0]
CU analog input characteristic value x2 / CU AI char x2
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-20.000
20.000
10.000
p0759[0]
CU analog input characteristic value x2 / CU AI char x2
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000
20.000
10.000
p0760[0]
CU analog input characteristic value y2 / CU AI char y2
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-1000.00 [%]
1000.00 [%]
100.00 [%]
p0760[0]
CU analog input characteristic value y2 / CU AI char y2
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [%]
1000.00 [%]
100.00 [%]
p0761[0]
CU analog input wire breakage monitoring response threshold / CU wire brk thr
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [mA]
20.00 [mA]
2.00 [mA]
p0761[0]
CU analog input wire breakage monitoring response threshold / CU wire brk thr
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [mA]
20.00 [mA]
2.00 [mA]
Machine data and parameters
948
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0762[0]
CU analog input wire breakage monitoring delay time / CU wire brk t_del
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: Unsigned16
Dynamic index: -
Function diagram: 9566
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
100 [ms]
p0762[0]
CU analog input wire breakage monitoring delay time / CU wire brk t_del
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN
Data type: Unsigned16
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
100 [ms]
p0763[0]
CU analog input offset / CU AI offset
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-20.000
20.000
0.000
p0763[0]
CU analog input offset / CU AI offset
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000
20.000
0.000
p0766[0]
CU analog input activate absolute value generation / CU AI AbsV act
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: 9566
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
1
0
p0766[0]
CU analog input activate absolute value generation / CU AI AbsV act
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN
Data type: Integer16
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
949
SINAMICS parameters
3.2 SINAMICS parameters
p0767[0]
BI: CU analog input signal source for inversion / CU AI inv s_s
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9566
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
p0767[0]
BI: CU analog input signal source for inversion / CU AI inv s_s
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0768[0]
CU analog input window to suppress noise / CU AI window
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9566
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [%]
20.00 [%]
0.00 [%]
p0768[0]
CU analog input window to suppress noise / CU AI window
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
20.00 [%]
0.00 [%]
p0769[0]
BI: CU analog input enable signal source / CU AI enab s_s
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9566
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
1
p0769[0]
BI: CU analog input enable signal source / CU AI enab s_s
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
950
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0771[0...2]
CI: Test sockets signal source / Test skt s_s
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 8134
CU_S120_DP,
P-Group: Terminals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r0772[0...2]
Test sockets output signal / TestSktsSignalVal
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8134
CU_S120_DP,
P-Group: Terminals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0774[0...2]
Test sockets output voltage / TestSkts U_output
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Terminals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p0776[0...2]
Test socket mode / Test skt mode
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: 8134
CU_S120_DP,
P-Group: Terminals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
96
99
99
p0777[0...2]
Test socket characteristic value x1 / Test skt char x1
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8134
CU_S120_DP,
P-Group: Terminals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100000.00 [%]
100000.00 [%]
0.00 [%]
p0778[0...2]
Test socket characteristic value y1 / Test skt char y1
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8134
CU_S120_DP,
P-Group: Terminals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [V]
4.98 [V]
2.49 [V]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
951
SINAMICS parameters
3.2 SINAMICS parameters
p0779[0...2]
Test socket characteristic value x2 / Test skt char x2
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8134
CU_S120_DP,
P-Group: Terminals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100000.00 [%]
427.9E9 [%]
100.00 [%]
p0780[0...2]
Test socket characteristic value y2 / Test skt char y2
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8134
CU_S120_DP,
P-Group: Terminals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [V]
4.98 [V]
4.98 [V]
p0783[0...2]
Test sockets offset / Test skt offset
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8134
CU_S120_DP,
P-Group: Terminals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-4.98 [V]
4.98 [V]
0.00 [V]
p0784[0...2]
Test socket limit on/off / TestSktLim on/off
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: 8134
CU_S120_DP,
P-Group: Terminals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
r0786[0...2]
Test socket scaling per volt / TestSktScal/Volt
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8134
CU_S120_DP,
P-Group: Terminals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0788[0...2]
Test sockets physical address / Test skt PhyAddr
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Terminals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 bin
1111 1111 1111 1111 1111
0000 bin
1111 1111 1111 bin
Machine data and parameters
952
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0789[0...2]
Test sockets physical address gain / TestSktPhyAddrGain
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Terminals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-340.28235E36
340.28235E36
1.00000
r0790[0...2]
Test sockets physical address signal value / TestSktsPhyAddrVal
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Terminals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0791[0...1]
CO: Fieldbus analog outputs / Fieldbus AO
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: PERCENT
Expert list: 0
Min:
Max:
Factory setting:
-200.000 [%]
200.000 [%]
0.000 [%]
p0795
CU digital inputs simulation mode / CU DI simulation
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S120_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2020, 2030,
2031, 2100, 2119, 2120, 2130,
2131, 2132, 2133
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
p0795
CU digital inputs simulation mode / CU DI simulation
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2019, 2020,
2021, 2030, 2031, 2032, 2033
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
953
SINAMICS parameters
3.2 SINAMICS parameters
p0796
CU digital inputs simulation mode setpoint / CU DI sim set
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S120_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2020, 2030,
2031, 2100, 2119, 2120, 2130,
2131, 2132, 2133
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
p0796
CU digital inputs simulation mode setpoint / CU DI sim set
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN
Data type: Unsigned32
Dynamic index: -
Function diagram: 2019, 2020,
2021, 2030, 2031, 2032, 2033
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
p0797[0]
CU analog input simulation mode / CU AI sim mode
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: Integer16
Dynamic index: -
Function diagram: 9566
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
1
0
p0797[0]
CU analog input simulation mode / CU AI sim mode
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN
Data type: Integer16
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0798[0]
CU analog input simulation mode setpoint / CU AI sim set
CU_S120_DP,
Can be changed: T, U
Calculated: -
Access level: 9
CU_S120_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-20.000
20.000
0.000
Machine data and parameters
954
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0798[0]
CU analog input simulation mode setpoint / CU AI sim set
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2040
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000
20.000
0.000
p0799[0...2]
CU inputs/outputs sampling time / CU I/O t_samp
CU_S_AC_DP,
Can be changed: C1(3)
Calculated: -
Access level: 3
CU_S_AC_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2020, 2030,
2031
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
5000.00 [µs]
4000.00 [µs]
p0799[0...2]
CU inputs/outputs sampling time / CU I/O t_samp
CU_S120_DP,
Can be changed: C1(3)
Calculated: -
Access level: 3
CU_S120_PN
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2020, 2030,
2031
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
5000.00 [µs]
4000.00 [µs]
p0806
BI: Inhibit master control / PcCtrl inhibit
A_INF, B_INF, HLA,
Can be changed: T
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r0807.0
BO: Master control active / PcCtrl active
A_INF, B_INF, HLA,
Can be changed: -
Calculated: -
Access level: 2
R_INF, S_INF, SERVO,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Displays, signals
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0809[0...2]
Copy Command Data Set CDS / Copy CDS
A_INF, B_INF, HLA,
Can be changed: T
Calculated: -
Access level: 8
R_INF, S_INF, TM41
Data type: Unsigned8
Dynamic index: -
Function diagram: 8560
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
15
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
955
SINAMICS parameters
3.2 SINAMICS parameters
p0809[0...2]
Copy Command Data Set CDS / Copy CDS
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned8
Dynamic index: -
Function diagram: 8560
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
15
0
p0810
BI: Command data set selection CDS bit 0 / CDS sel, bit 0
HLA, TM41
Can be changed: T
Calculated: -
Access level: 8
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 8560
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
p0810
BI: Command data set selection CDS bit 0 / CDS sel, bit 0
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 8560
SERVO_AC, VECTOR,
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0811
BI: Command data set selection CDS bit 1 / CDS sel, bit 1
A_INF, B_INF, HLA,
Can be changed: T
Calculated: -
Access level: 8
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 8560
SERVO_AC, TM41
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
p0811
BI: Command data set selection CDS bit 1 / CDS sel, bit 1
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 8560
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0812
BI: Command data set selection CDS bit 2 / CDS sel, bit 2
A_INF, B_INF, HLA,
Can be changed: T
Calculated: -
Access level: 8
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 8560
SERVO_AC, TM41,
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
956
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0813
BI: Command data set selection CDS bit 3 / CDS sel, bit 3
A_INF, B_INF, HLA,
Can be changed: T
Calculated: -
Access level: 8
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 8560
SERVO_AC, TM41,
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
0
p0819[0...2]
Copy Drive Data Set DDS / Copy DDS
HLA, SERVO,
Can be changed: C2(15)
Calculated: -
Access level: 2
SERVO_AC, TM41,
Data type: Unsigned8
Dynamic index: -
Function diagram: 8565
VECTOR, VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
31
0
p0819[0...2]
Copy Drive Data Set DDS / Copy DDS
ENC
Can be changed: C2(15)
Calculated: -
Access level: 8
Data type: Unsigned8
Dynamic index: -
Function diagram: 8565
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
31
0
p0820[0...n]
BI: Drive Data Set selection DDS bit 0 / DDS sel, bit 0
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, TM41,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 8565, 8575
VECTOR, VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0821[0...n]
BI: Drive Data Set selection DDS bit 1 / DDS sel, bit 1
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, TM41,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 8565, 8570
VECTOR, VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0822[0...n]
BI: Drive Data Set selection DDS bit 2 / DDS sel, bit 2
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, TM41,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 8565
VECTOR, VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
957
SINAMICS parameters
3.2 SINAMICS parameters
p0823[0...n]
BI: Drive Data Set selection DDS bit 3 / DDS sel, bit 3
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, TM41,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 8565
VECTOR, VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0824[0...n]
BI: Drive Data Set selection DDS bit 4 / DDS sel, bit 4
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, TM41,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 8565, 8575
VECTOR, VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0826[0...n]
Motor changeover motor number / Mot_chgov mot no
SERVO, SERVO_AC
Can be changed: C2(3)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: 8575
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
15
0
p0826[0...n]
Motor changeover motor number / Mot_chgov mot no
VECTOR, VECTOR_AC
Can be changed: C2(3)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: 8575
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
15
0
p0827[0...n]
Motor changeover status word bit number / Mot_chg ZSW bit no
SERVO, SERVO_AC,
Can be changed: C2(3)
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: MDS, p0130 Function diagram: 8575
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
15
0
p0828[0...n]
BI: Motor changeover feedback signal / Mot_chgov fdbk sig
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 8575
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
958
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0830.0...15
CO/BO: Motor changeover status word / Mot_chgov ZSW
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: 8575
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0831[0...15]
BI: Motor changeover contactor feedback / Mot_chg cont fdbk
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 8575
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r0832.0...15
CO/BO: Mot. changeover contactor feedback sig. status word / Mot_chgov fdbk ZSW
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned32
Dynamic index: -
Function diagram: 8575
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0833
Data set changeover configuration / DS_chgov config
HLA, SERVO, SERVO_AC Can be changed: C2(15)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 8575
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p0833
Data set changeover configuration / DS_chgov config
VECTOR, VECTOR_AC
Can be changed: C2(15)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 8575
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0010 bin
r0835.2
CO/BO: Data set changeover status word / Data set sw ZSW
ENC, TM41
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 8575
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
959
SINAMICS parameters
3.2 SINAMICS parameters
r0835.0...12
CO/BO: Data set changeover status word / Data set sw ZSW
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: -
Function diagram: 8575
VECTOR_AC
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0836.0...3
CO/BO: Command Data Set CDS selected / CDS selected
HLA
Can be changed: -
Calculated: -
Access level: 8
Data type: Unsigned8
Dynamic index: -
Function diagram: 8560
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r0836.0...3
CO/BO: Command Data Set CDS selected / CDS selected
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 2
S_INF, SERVO,
Data type: Unsigned8
Dynamic index: -
Function diagram: 8560
SERVO_AC, TM41,
P-Group: Displays, signals
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0837.0...4
CO/BO: Drive Data Set DDS selected / DDS selected
ENC, HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC, TM41,
Data type: Unsigned8
Dynamic index: -
Function diagram: 8565
VECTOR, VECTOR_AC
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0838[0...3]
Motor/Encoder Data Set selected / MDS/EDS selected
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: -
Function diagram: 8565
VECTOR_AC
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0839
Motor changeover contactor control delay time / Mot_chg ctrl t_del
SERVO, SERVO_AC,
Can be changed: C2(3)
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
500 [ms]
0 [ms]
Machine data and parameters
960
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0840[0...n]
BI: ON / OFF (OFF1) / ON / OFF (OFF1)
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2501
VECTOR_AC
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0840[0...n]
BI: ON / OFF (OFF1) / ON / OFF (OFF1)
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 3
S_INF
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 8720, 8820,
8920
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0840
BI: ON / OFF (OFF1) / ON / OFF (OFF1)
TM41
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9677
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0844[0...n]
BI: No coast-down / coast-down (OFF2) signal source 1 / OFF2 s_s 1
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2501, 8720,
VECTOR_AC
8820, 8920
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p0844[0...n]
BI: No coast-down / coast-down (OFF2) signal source 1 / OFF2 s_s 1
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 3
S_INF
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 8720, 8820,
8920
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
961
SINAMICS parameters
3.2 SINAMICS parameters
p0844
BI: No coast-down / coast-down (OFF2) / OFF2
TM41
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9677
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p0845[0...n]
BI: No coast-down / coast-down (OFF2) signal source 2 / OFF2 s_s 2
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2501, 8720,
VECTOR_AC
8820, 8920
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p0845[0...n]
BI: No coast-down / coast-down (OFF2) signal source 2 / OFF2 s_s 2
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 3
S_INF
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 8720, 8820,
8920
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p0848[0...n]
BI: No Quick Stop / Quick Stop (OFF3) signal source 1 / OFF3 s_s 1
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2501
VECTOR_AC
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p0848[0...n]
BI: No Quick Stop / Quick Stop (OFF3) signal source 1 / OFF3 s_s 1
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 8
S_INF
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
1
p0848
BI: No Quick Stop / Quick Stop (OFF3) / OFF3
TM41
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9677
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
962
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0849[0...n]
BI: No Quick Stop / Quick Stop (OFF3) signal source 2 / OFF3 s_s 2
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2501
VECTOR_AC
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p0849[0...n]
BI: No Quick Stop / Quick Stop (OFF3) signal source 2 / OFF3 s_s 2
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 8
S_INF
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
1
p0852[0...n]
BI: Enable operation/inhibit operation / Enable operation
A_INF, HLA, R_INF,
Can be changed: T
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2501, 8820,
SERVO_AC, VECTOR,
8920
VECTOR_AC
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p0852
BI: Enable operation/inhibit operation / Enable operation
TM41
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9677
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p0854[0...n]
BI: Control by PLC/no control by PLC / Master ctrl by PLC
A_INF, B_INF, HLA,
Can be changed: T
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2501, 8720,
SERVO_AC, VECTOR,
8820, 8920
VECTOR_AC
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p0854
BI: Control by PLC/no control by PLC / Master ctrl by PLC
TM41
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 9677, 9678
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
963
SINAMICS parameters
3.2 SINAMICS parameters
p0854
BI: Control by PLC/no control by PLC / Master ctrl by PLC
ENC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2501, 8720,
8820, 8920
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p0855[0...n]
BI: Unconditionally release holding brake / Uncond open brake
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2501, 2701,
2707
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0856[0...n]
BI: Enable speed controller / n_ctrl enable
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2501, 2701,
2707
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p0856[0...n]
BI: Enable velocity controller / v_ctrl enable
SERVO (Lin),
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2501, 2701,
2707
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p0857
Power unit monitoring time / PU t_mon
A_INF, B_INF, HLA,
Can be changed: T
Calculated: -
Access level: 2
R_INF, S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8760, 8864,
SERVO_AC, VECTOR,
8964
VECTOR_AC
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
100.0 [ms]
60000.0 [ms]
6000.0 [ms]
Machine data and parameters
964
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0858[0...n]
BI: Unconditionally close holding brake / Uncond close brake
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170 Function diagram: 2501, 2701,
2707
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
10251.13
p0860
BI: Line contactor feedback signal / Line contact fdbk
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2634, 8734,
SERVO_AC, VECTOR,
8834, 8934
VECTOR_AC
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
863.1
p0861
Line contactor monitoring time / Line cont t_mon
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 2
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2634, 8734,
SERVO_AC, VECTOR,
8834, 8934
VECTOR_AC
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
5000 [ms]
100 [ms]
p0862
Power unit ON-delay / PU t_on
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2610, 8732,
SERVO_AC, VECTOR,
8832, 8932
VECTOR_AC
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
65000 [ms]
0 [ms]
r0863.0
CO/BO: System pressure status word / p_sys ZSW
HLA
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
965
SINAMICS parameters
3.2 SINAMICS parameters
r0863.0...2
CO/BO: Drive coupling status word/control word / CoupleZSW/STW
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 2
S_INF, SERVO,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0864
BI: System pressure available / p_sys available
HLA
Can be changed: T
Calculated: -
Access level: 2
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1
p0864
BI: Infeed operation / INF operation
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: 2610, 8710,
8910
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0865
System pressure switch-on threshold / p_sys thr
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [bar]
10000.0 [bar]
0.0 [bar]
p0866
System pressure switch-on threshold hysteresis / p_sys hyst
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
10000.0 [%]
20.0 [%]
p0867
Power unit main contactor holding time after OFF1 / PU t_MC after OFF1
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [ms]
5000.0 [ms]
50.0 [ms]
Machine data and parameters
966
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0868
Power unit debounce time/wait time / PU t_debnc/t_wait
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
65000 [ms]
65000 [ms]
p0869
Sequence control configuration / Seq_ctrl config
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p0869
Sequence control configuration / Seq_ctrl config
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 3
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: 8732, 8832,
8932
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p0870
BI: Close main contactor / Close main cont
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
r0873
CO/BO: Infeed total operation / INF total op
A_INF, R_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: Unsigned16
Dynamic index: -
Function diagram: 8732, 8832
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r0873
CO/BO: Infeed total operation / INF total op
B_INF, S_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: 8732, 8832
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
967

 

 

 

 

 

 

 

Content      ..     12      13      14      15     ..