SINUMERIK 840D sl. Service - Configuring Commissioning. Manual (2011-2020) - page 12

 

  Index      Manuals     SINUMERIK 840D sl. Service - Configuring Commissioning. Manual (2011-2020)

 

Search            copyright infringement  

 

   

 

   

 

Content      ..     10      11      12      13     ..

 

 

 

SINUMERIK 840D sl. Service - Configuring Commissioning. Manual (2011-2020) - page 12

 

 

SINAMICS parameters
3.2 SINAMICS parameters
All objects: A_INF, B_INF, CU_S_AC_DP, CU_S_AC_PN, CU_S120_DP, CU_S120_PN, ENC, HLA,
HUB, R_INF, S_INF, SERVO, SERVO_AC, TB30, TM120, TM15, TM150, TM15DI_DO, TM17, TM31,
TM41, TM54F_MA, TM54F_SL, VECTOR, VECTOR_AC
r0002
Control Unit operating display / CU op_display
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
117
-
r0002
Drive operating display / Drv op_display
HLA
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
r0002
Drive operating display / Drv op_display
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
r0002
Infeed operating display / INF op_display
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
r0002
Infeed operating display / INF op_display
B_INF
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
Machine data and parameters
762
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0002
TM120 operating display / TM120 op_display
TM120
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
r0002
TM15 operating display / TM15 op_display
TM15
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
r0002
TM150 operating display / TM150 op_display
TM150
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
r0002
TM15DI/DO operating display / TM15D op_display
TM15DI_DO
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
r0002
TM17 operating display / TM17 op_display
TM17
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
r0002
TM31 operating display / TM31 op_display
TM31
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
763
SINAMICS parameters
3.2 SINAMICS parameters
r0002
TM41 operating display / TM41 op_display
TM41
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
r0002
TB30 operating display / TB30 op_display
TB30
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
r0002
TM54F operating display / TM54F op_display
TM54F_MA, TM54F_SL Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
r0002
Encoder DO operating display / Enc DO op_disp
ENC
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
r0002
DRIVE-CLiQ Hub Module operating display / Hub op_display
HUB
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
250
-
p0003
BOP access level / BOP acc_level
CU_S_AC_DP,
Can be changed: C1, T, U
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: All groups
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
4
1
Machine data and parameters
764
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0004
BOP display filter / BOP disp_filter
CU_S_AC_DP,
Can be changed: C2(1), T, U
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: All groups
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
99
0
p0005[0...1]
BOP operating display selection / BOP op_disp sel
All objects
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
[0] 2
[1] 0
p0006
BOP operating display mode / BOP op_ disp mode
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN, ENC,
HLA, HUB, TB30,
Not for motor type: -
Scaling: -
Expert list: 1
TM120, TM15, TM150,
Min:
Max:
Factory setting:
TM15DI_DO, TM17,
4
4
4
TM31, TM41,
TM54F_MA, TM54F_SL
p0006
BOP operating display mode / BOP op_ disp mode
A_INF, B_INF, R_INF,
Can be changed: T, U
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: Integer16
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: -
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4
4
p0007
BOP backg6round lighting / BOP lighting
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [s]
2000 [s]
0 [s]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
765
SINAMICS parameters
3.2 SINAMICS parameters
p0008
BOP drive object after booting / BOP DO after boot
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
65535
1
p0009
Device commissioning parameter filter / Dev com par_filt
CU_S_AC_DP,
Can be changed: C1, T
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: All groups
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
10000
1
p0010
Drive commissioning parameter filter / Drv com par_filt
HLA
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
10000
1
p0010
Drive commissioning parameter filter / Drv com par_filt
SERVO, SERVO_AC,
Can be changed: C2(1), T
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: -
Function diagram: 2800, 2818
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
10000
1
p0010
Infeed commissioning parameter filter / INF com par_filt
A_INF, B_INF, R_INF,
Can be changed: C2(1), T
Calculated: -
Access level: 1
S_INF
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
30
1
p0010
TM120 commissioning parameter filter / TM120 com par_filt
TM120
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
30
0
Machine data and parameters
766
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0010
TM15 commissioning parameter filter / TM15 com par_filt
TM15
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
30
0
p0010
TM150 commissioning parameter filter / TM150 com par_filt
TM150
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
30
0
p0010
TM15DI/DO commissioning the parameterizing filter / TM15D com par_filt
TM15DI_DO
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
30
0
p0010
TM17 commissioning parameter filter / TM17 com par_filt
TM17
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
30
0
p0010
TM31 commissioning parameter filter / TM31 com par_filt
TM31
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
30
0
p0010
TM41 commissioning parameter filter / TM41 com par_filt
TM41
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
30
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
767
SINAMICS parameters
3.2 SINAMICS parameters
p0010
TB30 commissioning parameter filter / TB30 com par_filt
TB30
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
30
0
p0010
TM54F commissioning parameter filter / TM54F com par_filt
TM54F_MA
Can be changed: C2(1), T
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: 2891
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
95
0
p0010
TM54F commissioning parameter filter / TM54F com par_filt
TM54F_SL
Can be changed: C2(1), T
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: 2891
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
95
0
p0010
Encoder DO commissioning parameter filter / EncDO com par_filt
ENC
Can be changed: C2(1), T, U
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: All groups
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
30
0
p0011
BOP password entry (p0013) / BOP pw ent p13
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Functions
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p0012
BOP password acknowledgment (p0013) / BOP pw ackn p13
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Functions
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
Machine data and parameters
768
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0013[0...49]
BOP user-defined list / BOP list
All objects
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Functions
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p0015
Macro drive unit / Macro drv unit
CU_S_AC_DP,
Can be changed: C1
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
999999
0
p0015
Macro drive object / Macro DO
A_INF, B_INF, HLA,
Can be changed: C2(1)
Calculated: -
Access level: 1
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, TM120,
P-Group: Commands
Unit group: -
Unit selection: -
TM150, TM15DI_DO,
TM31, VECTOR,
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC
Min:
Max:
Factory setting:
0
999999
0
p0016
Activate BOP user-defined list / BOP user list act
CU_S_AC_DP,
Can be changed: C1, T, U
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: All groups
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
r0018
Control Unit firmware version / CU FW version
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
-
r0019.0...14
CO/BO: Control word BOP / STW BOP
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: 9912
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
769
SINAMICS parameters
3.2 SINAMICS parameters
r0020
Velocity setpoint smoothed / v_set smth
HLA
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r0020
Speed setpoint smoothed / n_set smth
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5020, 6799
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0020
Velocity setpoint smoothed / v_set smth
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5020, 6799
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r0020
Speed setpoint smoothed / n_set smth
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 8
S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 0
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0021
CO: Actual velocity smoothed / v_act smth
HLA
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r0021
CO: Actual speed smoothed / n_act smth
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4700, 4710
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
Machine data and parameters
770
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0021
CO: Actual velocity smoothed / v_act smth
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4700, 4710
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r0021
CO: Actual speed smoothed / n_act smth
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6799
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0021
CO: Actual speed smoothed / n_act smth
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 8
S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 0
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0022
Actual velocity smoothed / v_act smth
HLA
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r0022
Speed actual value rpm smoothed / n_ActV rpm smth
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4700, 4710
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0022
Actual velocity smoothed / v_act smth
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4700, 4710
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
771
SINAMICS parameters
3.2 SINAMICS parameters
r0022
Speed actual value rpm smoothed / n_ActV rpm smth
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6799
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0022
Speed actual value rpm smoothed / n_ActV rpm smth
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 8
S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 0
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0024
Output frequency smoothed / f_outp smooth
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5300, 5730
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
r0024
Output frequency smoothed / f_outp smooth
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6300, 6799
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
r0024
CO: Line supply frequency smoothed / f_line smooth
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8850, 8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
r0025
CO: Output voltage smoothed / U_outp smooth
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6300,
6799
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
Machine data and parameters
772
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0025[0...4]
CO: Input voltage smoothed / U_inp smth
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8850, 8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
r0026
CO: DC link voltage smoothed / Vdc smth
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 8750,
8850, 8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0026
CO: DC link voltage smoothed / Vdc smth
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6799, 8750,
8850, 8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0026
CO: DC link voltage smoothed / Vdc smth
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 2
S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6799,
8750, 8850, 8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0027
CO: Absolute actual current smoothed / I_act AbsV smth
A_INF, R_INF, S_INF,
Can be changed: -
Calculated: -
Access level: 2
SERVO, SERVO_AC,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6799,
VECTOR, VECTOR_AC
8850, 8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
773
SINAMICS parameters
3.2 SINAMICS parameters
r0027
CO: Absolute actual current smoothed / I_act AbsV smth
B_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8750
P-Group: Displays, signals
Unit group: 6_4
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r0028
Modulation depth smoothed / mod_depth smth
A_INF, R_INF, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6799,
VECTOR_AC
8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0028
Modulation depth smoothed / mod_depth smth
S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6799,
8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 0
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0029
Current actual value field-generating smoothed / Id_act smth
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6799
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0029
Reactive current actual value smoothed / I_react smooth
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8850, 8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0030
Current actual value torque-generating smoothed / Iq_act smth
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6799
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
Machine data and parameters
774
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0030
Current actual value force generating smoothed / Iq_act smth
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6799
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0030
Active current actual value smoothed / I_act smth
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8850, 8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0031
Force actual value smoothed / F_ActV smth
HLA
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 8_1
Unit selection: p0505
Not for motor type: -
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [N]
- [N]
- [N]
r0031
Actual torque smoothed / M_act smth
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6799
P-Group: Displays, signals
Unit group: 7_1
Unit selection: p0505
Not for motor type: -
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [Nm]
- [Nm]
- [Nm]
r0031
Force actual value smoothed / F_ActV smth
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6799
P-Group: Displays, signals
Unit group: 8_1
Unit selection: p0505
Not for motor type: -
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [N]
- [N]
- [N]
r0031
Actual torque smoothed / M_act smth
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 8
S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 7_2
Unit selection: p0505
Not for motor type: -
Scaling: p2003
Expert list: 0
Min:
Max:
Factory setting:
- [Nm]
- [Nm]
- [Nm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
775
SINAMICS parameters
3.2 SINAMICS parameters
r0032
CO: Active power actual value smoothed / P_ActV_act smth
A_INF, HLA, R_INF,
Can be changed: -
Calculated: -
Access level: 2
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6799,
SERVO_AC, VECTOR,
8750, 8850, 8950
VECTOR_AC
P-Group: Displays, signals
Unit group: 14_10
Unit selection: p0505
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r0032
CO: Active power actual value smoothed / P_ActV_act smth
B_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6799,
8750, 8850, 8950
P-Group: Displays, signals
Unit group: 14_10
Unit selection: p0505
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r0033
Torque utilization smoothed / M_util smth
HLA
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8012
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0033
Torque utilization smoothed / M_util smth
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8012
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0033
Force utilization smoothed / F_util smth
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8012
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0033
Torque utilization smoothed / M_util smth
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8012
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
Machine data and parameters
776
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0033
Torque utilization smoothed / M_util smth
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 8
S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 0
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0034
CO: Motor utilization thermal / Mot_util therm
HLA
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8017, 8019
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: PERCENT
Expert list: 0
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0034
CO: Motor utilization thermal / Mot_util therm
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8017, 8019
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0035
CO: Motor temperature / Mot temp
HLA
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8016, 8017
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: p2006
Expert list: 0
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r0035
CO: Motor temperature / Mot temp
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8016, 8017
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r0035
CO: Temperature input / Temp_input
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8850, 8950
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
777
SINAMICS parameters
3.2 SINAMICS parameters
r0035
CO: Temperature input / Temp_input
B_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8750
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r0036
CO: Power unit overload I2t / PU overload I2t
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8021
SERVO_AC, VECTOR,
P-Group: Displays, signals
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0037[0...1]
Control Unit temperature / CU temp
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Displays, signals
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r0037[0...1]
CO: HLA temperature / HLA temp
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r0037[0...20]
CO: Power unit temperatures / PU temperatures
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8021
SERVO_AC, VECTOR,
P-Group: Displays, signals
Unit group: 21_1
Unit selection: p0505
VECTOR_AC
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
r0038
Power factor smoothed / Cos phi smooth
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 9
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6799, 8850,
8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
778
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0038
Power factor smoothed / Cos phi smooth
A_INF, R_INF, S_INF,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6799, 8850,
8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0039[0...2]
CO: Energy display / Energy disp
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kWh]
- [kWh]
- [kWh]
p0040
Reset energy consumption display / Energy usage reset
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
r0041
Energy consumption saved / Energy cons saved
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kWh]
- [kWh]
- [kWh]
r0042[0...2]
CO: Process energy display / Proc energy disp
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Wh]
- [Wh]
- [Wh]
p0043
BI: Enable energy usage display / Enab energy usage
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
P-Group: Communications
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
779
SINAMICS parameters
3.2 SINAMICS parameters
r0044
Thermal converter utilization / Conv_util therm
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p0045
Display values smoothing time constant / Disp_val Tc_smth
HLA, S_INF, SERVO,
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4715, 5610,
VECTOR_AC
5730, 6714, 8012
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
10000.00 [ms]
1.00 [ms]
p0045
Display values smoothing time constant / Disp_val Tc_smth
A_INF, R_INF
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ms]
10000.00 [ms]
150.00 [ms]
r0046.0...30
CO/BO: Missing enable signal / Missing enable sig
HLA
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 2634
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0046.0...31
CO/BO: Missing enable signal / Missing enable sig
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 2634
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0046.0...31
CO/BO: Missing enable signal / Missing enable sig
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC (Lin)
Data type: Unsigned32
Dynamic index: -
Function diagram: 2634
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
780
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0046.0...31
CO/BO: Missing enable signal / Missing enable sig
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 2634
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0046.0...29
CO/BO: Missing enable signal / Missing enable sig
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 8834, 8934
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0046.0...29
CO/BO: Missing enable signal / Missing enable sig
B_INF
Can be changed: -
Calculated: -
Access level: 1
Data type: Unsigned32
Dynamic index: -
Function diagram: 8734
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0047
Identification status / ID status
HLA
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
200
-
r0047
Identification status / ID status
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
104
-
r0047
Motor data identification and speed controller optimization / MotID and n_opt
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
300
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
781
SINAMICS parameters
3.2 SINAMICS parameters
r0049[0...3]
Motor data set/encoder data set effective / MDS/EDS effective
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: -
Function diagram: 8565
VECTOR_AC
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0050.0...3
CO/BO: Command Data Set CDS effective / CDS effective
HLA
Can be changed: -
Calculated: -
Access level: 8
Data type: Unsigned8
Dynamic index: -
Function diagram: 8560
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r0050.0...3
CO/BO: Command Data Set CDS effective / CDS effective
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 2
S_INF, SERVO,
Data type: Unsigned8
Dynamic index: -
Function diagram: 8560
SERVO_AC, TM41,
P-Group: Displays, signals
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0051.0...4
CO/BO: Drive Data Set DDS effective / DDS effective
ENC, HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC, TM41,
Data type: Unsigned8
Dynamic index: -
Function diagram: 8565
VECTOR, VECTOR_AC
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0056.1...15
CO/BO: Status word, closed-loop control / ZSW cl-lp ctrl
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2526
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0056.0...15
CO/BO: Status word, closed-loop control / ZSW cl-lp ctrl
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 2526
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
782
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0056.0...13
CO/BO: Status word, closed-loop control / ZSW cl-lp ctrl
VECTOR (F3E),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (F3E)
Data type: Unsigned16
Dynamic index: -
Function diagram: 2526
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0060
CO: Velocity setpoint before the setpoint filter / v_set before filt
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4965
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r0060
CO: Speed setpoint before the setpoint filter / n_set before filt
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2701, 2704,
5020, 6030, 6799
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0060
CO: Velocity setpoint before the setpoint filter / v_set before filt
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2701, 2704,
5020, 6030, 6799
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r0061[0...1]
CO: Actual velocity unsmoothed / v_act unsmoothed
HLA
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4965
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
783
SINAMICS parameters
3.2 SINAMICS parameters
r0061[0...1]
CO: Actual speed unsmoothed / n_act unsmoothed
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4700, 4710,
4715
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0061[0...1]
CO: Actual velocity unsmoothed / v_act unsmoothed
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4700, 4710,
4715
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r0061[0...2]
CO: Actual speed unsmoothed / n_act unsmoothed
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4700, 4710,
4715
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0061
CO: Actual speed unsmoothed / n_act unsmoothed
ENC
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4700, 4710,
4715
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0061
CO: Actual velocity unsmoothed / v_act unsmoothed
ENC (Lin_enc)
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4700, 4710,
4715
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
Machine data and parameters
784
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0062
CO: Velocity setpoint after the filter / v_set after filter
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4965
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r0062
CO: Speed setpoint after the filter / n_set after filter
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5019, 5020,
5030, 5042, 5210
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0062
CO: Velocity setpoint after the filter / v_set after filter
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5019, 5020,
5030, 5042, 5210
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r0062
CO: Speed setpoint after the filter / n_set after filter
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6020, 6030,
6031
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0063
CO: Actual velocity smoothed / v_act smth
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4965
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
785
SINAMICS parameters
3.2 SINAMICS parameters
r0063
CO: Actual speed smoothed / n_act smth
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4700, 4710,
5019, 5300, 8019
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0063
CO: Actual velocity smoothed / v_act smth
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4700, 4710,
5019, 5300, 8019
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r0063[0...2]
CO: Speed actual value / n_ActV
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4702, 4715,
6799
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0063
CO: Speed actual value / n_ActV
TM41
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0064
CO: Velocity controller system deviation / v_ctrl SysDev
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
Machine data and parameters
786
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0064
CO: Speed controller system deviation / n_ctrl SysDev
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040, 6040
P-Group: Displays, signals
Unit group: 3_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [rpm]
- [rpm]
- [rpm]
r0064
CO: Velocity controller system deviation / v_ctrl SysDev
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5040, 6040
P-Group: Displays, signals
Unit group: 4_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [m/min]
- [m/min]
- [m/min]
r0065
Slip frequency / f_slip
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6310, 6700,
6727, 6730, 6732
P-Group: Displays, signals
Unit group: 2_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
r0066
CO: Output frequency / f_outp
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5300, 5730,
6300, 6310, 6730, 6731, 6799
P-Group: Displays, signals
Unit group: 2_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
r0066[0...1]
CO: Line frequency / f_line
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8850, 8864,
8950, 8964
P-Group: Displays, signals
Unit group: 2_1
Unit selection: p0505
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
787
SINAMICS parameters
3.2 SINAMICS parameters
r0067[0...1]
CO: Pressure actual value A / Press ActV A
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4970
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [bar]
- [bar]
- [bar]
r0067
CO: Output current maximum / I_outp max
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5722, 6300,
6301, 6640
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0067[0...1]
Absolute current value permissible / I_AbsV perm
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0068[0...1]
CO: Pressure actual value B / Press ActV B
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4970
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [bar]
- [bar]
- [bar]
r0068
CO: Absolute current actual value / I_act AbsV
A_INF, R_INF, S_INF,
Can be changed: -
Calculated: -
Access level: 3
SERVO, SERVO_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 7017,
8017, 8019, 8021, 8850, 8950
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
Machine data and parameters
788
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0068[0...1]
CO: Absolute current actual value / I_act AbsV
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6300, 6714,
6799, 7017, 8017, 8019, 8029,
8021
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0068
CO: DC current in the DC link / Idc DC link
B_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8021, 8750
P-Group: Displays, signals
Unit group: 6_4
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r0069
CO: System pressure actual value / Sys press ActV
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [bar]
- [bar]
- [bar]
r0069[0...8]
CO: Phase current actual value / I_phase ActV
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5700, 5730,
7008
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
r0069[0...8]
CO: Phase current actual value / I_phase ActV
A_INF, R_INF, S_INF,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6730, 6731,
6732, 7983, 7987, 8850, 8950
P-Group: Displays, signals
Unit group: 6_5
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [A]
- [A]
- [A]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
789
SINAMICS parameters
3.2 SINAMICS parameters
r0070[0...1]
CO: Valve position voltage setpoint before inversion / U_set before inv
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4966
P-Group: Displays, signals
Unit group: 5_2
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0070
CO: Actual DC link voltage / Vdc act val
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730
P-Group: Displays, signals
Unit group: 5_2
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0070
CO: Actual DC link voltage / Vdc act val
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6723, 6724,
6730, 6731, 6799
P-Group: Displays, signals
Unit group: 5_2
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0070
CO: Actual DC link voltage / Vdc act val
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8750, 8850,
8910, 8940, 8950, 8964
P-Group: Displays, signals
Unit group: 5_2
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0071[0...1]
CO: Valve position voltage setpoint / Valve U_set
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4966
P-Group: Displays, signals
Unit group: 5_2
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
Machine data and parameters
790
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0071
Maximum output voltage / U_output max
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6301, 6640,
6700, 6722, 6723, 6724, 6725,
6727
P-Group: Displays, signals
Unit group: 5_1
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
r0072[0...1]
CO: Valve position voltage actual value / Valve U_act
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 5_2
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0072
CO: Output voltage / U_output
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5700, 5730,
6730, 6731, 6799
P-Group: Displays, signals
Unit group: 5_1
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
r0072[0...4]
CO: Input voltage / U_inp
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8850, 8950
P-Group: Displays, signals
Unit group: 5_1
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
r0073[0...1]
Controller valve position voltage setpoint / Valve U_set
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4965, 4970
P-Group: Displays, signals
Unit group: 5_2
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
791
SINAMICS parameters
3.2 SINAMICS parameters
r0073
Maximum modulation depth / mod_depth max
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6723, 6724,
6725
P-Group: Modulation
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0074
CO: Piston position with respect to the piston zero point / Piston pos zero
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0074
CO: Modulation depth / mod_depth
A_INF, R_INF, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6730,
VECTOR_AC
6731, 6799, 8940, 8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0074
CO: Modulation depth / mod_depth
S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6730,
6731, 6799, 8940, 8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 0
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0075
CO: Current setpoint field-generating / Id_set
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5700, 5714,
5722
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: REL
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
Machine data and parameters
792
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0075
CO: Current setpoint field-generating / Id_set
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6700, 6714,
6725
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: REL
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0075
CO: Reactive current setpoint / I_react_set
A_INF, R_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7997, 8945,
8946
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0075
CO: Reactive current setpoint / I_react_set
S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7997, 8945,
8946
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 0
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0076
CO: Current actual value field-generating / Id_act
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5700, 5714,
5730, 6700, 6714, 6799
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0076[0...1]
CO: Current actual value field-generating / Id_act
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5700, 5714,
5730, 6700, 6714, 6799
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
793
SINAMICS parameters
3.2 SINAMICS parameters
r0076
CO: Reactive current actual value / I_reactive_ActV
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8810, 8850,
8910, 8946, 8950
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0077
CO: Current setpoint torque-generating / Iq_set
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5700, 5714,
5722
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: REL
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0077
CO: Current setpoint force-generating / Iq_set
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5700, 5714,
5722
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: REL
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0077
CO: Current setpoint torque-generating / Iq_set
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6700, 6710
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: REL
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0077
CO: Active current setpoint / I_act_set
A_INF, R_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7997, 8910,
8940, 8945
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
Machine data and parameters
794
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0077
CO: Active current setpoint / I_act_set
S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7997, 8910,
8940, 8945
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 0
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0078[0...1]
CO: Current actual value torque-generating / Iq_act
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5700, 5714,
5730
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0078[0...1]
CO: Current actual value force-generating / Iq_act
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5700, 5714,
5730
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0078[0...1]
CO: Current actual value torque-generating / Iq_act
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6310, 6700,
6714, 6799
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0078
CO: Active current actual value / I_active_act
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8810, 8850,
8910, 8946, 8950
P-Group: Displays, signals
Unit group: 6_2
Unit selection: p0505
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
795
SINAMICS parameters
3.2 SINAMICS parameters
r0079
CO: Total force setpoint / F_set total
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4970
P-Group: Displays, signals
Unit group: 8_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [N]
- [N]
- [N]
r0079[0...1]
CO: Torque setpoint total / M_set total
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5610
P-Group: Displays, signals
Unit group: 7_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [Nm]
- [Nm]
- [Nm]
r0079[0...1]
CO: Total force setpoint / F_set total
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5610
P-Group: Displays, signals
Unit group: 8_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [N]
- [N]
- [N]
r0079
CO: Torque setpoint / M_set
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6020, 6060,
6710
P-Group: Displays, signals
Unit group: 7_1
Unit selection: p0505
Not for motor type: REL
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [Nm]
- [Nm]
- [Nm]
r0080[0...1]
CO: Force actual value / F_ActV
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4970
P-Group: Displays, signals
Unit group: 8_1
Unit selection: p0505
Not for motor type: -
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [N]
- [N]
- [N]
r0080
CO: Torque actual value / M_ActV
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730
P-Group: Displays, signals
Unit group: 7_1
Unit selection: p0505
Not for motor type: -
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [Nm]
- [Nm]
- [Nm]
Machine data and parameters
796
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0080
CO: Force actual value / F_ActV
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730
P-Group: Displays, signals
Unit group: 8_1
Unit selection: p0505
Not for motor type: -
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [N]
- [N]
- [N]
r0080[0...1]
CO: Torque actual value / M_ActV
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6714, 6799
P-Group: Displays, signals
Unit group: 7_1
Unit selection: p0505
Not for motor type: -
Scaling: p2003
Expert list: 1
Min:
Max:
Factory setting:
- [Nm]
- [Nm]
- [Nm]
r0081
CO: Torque utilization / M_utilization
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8012
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0081
CO: Force utilization / F_utilization
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8012
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0081
CO: Torque utilization / M_utilization
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8012
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0082[0...1]
CO: Active power actual value / P_act
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730
P-Group: Displays, signals
Unit group: 14_8
Unit selection: p0505
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
797
SINAMICS parameters
3.2 SINAMICS parameters
r0082[0...3]
CO: Active power actual value / P_act
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730
P-Group: Displays, signals
Unit group: 14_5
Unit selection: p0505
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r0082[0...3]
CO: Active power actual value / P_act
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730
P-Group: Displays, signals
Unit group: 14_8
Unit selection: p0505
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r0082[0...2]
CO: Active power actual value / P_act
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6714, 6799
P-Group: Displays, signals
Unit group: 14_5
Unit selection: p0505
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r0082
CO: Active power actual value / P_act
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8750, 8850,
8950
P-Group: Displays, signals
Unit group: 14_7
Unit selection: p0505
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r0082
CO: Active power actual value / P_act
B_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8750, 8850,
8950
P-Group: Displays, signals
Unit group: 14_7
Unit selection: p0505
Not for motor type: -
Scaling: r2004
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r0083
CO: Flux setpoint / Flux set
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5722
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
Machine data and parameters
798
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0083
CO: Flux setpoint / Flux set
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0084
CO: Flux actual value / Flux ActV
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5722
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0084[0...1]
CO: Flux actual value / Flux ActV
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6726, 6730,
6732
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: PERCENT
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
r0087
CO: Actual power factor / Cos phi act
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6714, 6730,
6732, 6799
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0088
CO: DC link voltage setpoint / Vdc setpoint
A_INF, R_INF, SERVO
Can be changed: -
Calculated: -
Access level: 3
(Tech_ctrl), SERVO_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940, 8964
(Tech_ctrl)
P-Group: Displays, signals
Unit group: 5_2
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0088
CO: DC link voltage setpoint / Vdc setpoint
VECTOR (Tech_ctrl),
Can be changed: -
Calculated: -
Access level: 3
VECTOR_AC (Tech_ctrl)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: 5_2
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
799
SINAMICS parameters
3.2 SINAMICS parameters
r0088
CO: DC link voltage setpoint / Vdc setpoint
S_INF
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940, 8964
P-Group: Displays, signals
Unit group: 5_2
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 0
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0089[0...2]
Actual phase voltage / U_phase U ActV
A_INF, R_INF, S_INF,
Can be changed: -
Calculated: -
Access level: 3
SERVO, SERVO_AC,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 5730, 6730
VECTOR, VECTOR_AC
P-Group: Displays, signals
Unit group: 5_3
Unit selection: p0505
Not for motor type: -
Scaling: p2001
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p0092
Clock synchronous operation pre-assignment/check / Clk sync op pre-as
CU_S_AC_DP,
Can be changed: C1(1)
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
r0093
CO: Pole position angle electrically scaled / Pole pos el scale
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4710
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2005
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
r0093
CO: Pole position angle electrically scaled / Pole pos el scale
VECTOR (n/M),
Can be changed: -
Calculated: -
Access level: 8
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4710
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2005
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
r0094
CO: Piston position actual value / Piston pos ActV
HLA
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2005
Expert list: 1
Min:
Max:
Factory setting:
- [mm]
- [mm]
- [mm]
Machine data and parameters
800
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0094
CO: Transformation angle / Transformat_angle
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 4700, 4702,
4710, 6300, 6714, 6730, 6731,
6732
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2005
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
r0094
CO: Transformation angle / Transformat_angle
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8850, 8950
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2005
Expert list: 1
Min:
Max:
Factory setting:
- [°]
- [°]
- [°]
r0095
Maximum number of drive objects / DO qty max
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Data sets
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
24
24
-
p0097
Select drive object type / Select DO type
CU_S_AC_DP,
Can be changed: C1(1)
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Topology
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
24
0
r0098[0...5]
Actual device topology / Device_act topo
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Topology
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0099[0...5]
Device target topology / Device_target topo
CU_S_AC_DP,
Can be changed: C1(1)
Calculated: -
Access level: 1
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Topology
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
801
SINAMICS parameters
3.2 SINAMICS parameters
p0100
IEC/NEMA Standards / IEC/NEMA Standards
HLA
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: SESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0100
IEC/NEMA Standards / IEC/NEMA Standards
SERVO, SERVO_AC
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: SESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0100
IEC/NEMA Standards / IEC/NEMA Standards
VECTOR, VECTOR_AC
Can be changed: C2(1, 2)
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: SESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0101[0...n]
Drive object numbers / DO numbers
CU_S_AC_DP,
Can be changed: C1(1)
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: r0095
Function diagram: -
CU_S120_DP,
P-Group: Topology
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
62
0
r0102[0...1]
Number of drive objects / DO count
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Topology
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0103[0...n]
Application-specific view / Appl_spec view
CU_S_AC_DP,
Can be changed: C1(2)
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned16
Dynamic index: r0095
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
999
0
Machine data and parameters
802
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0103
Application-specific view / Appl_spec view
A_INF, B_INF, HLA,
Can be changed: -
Calculated: -
Access level: 2
R_INF, S_INF, SERVO,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
-
p0105
Activate/deactivate drive object / DO act/deact
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
1
p0105
Activate/deactivate drive object / DO act/deact
A_INF, B_INF, ENC,
Can be changed: T
Calculated: -
Access level: 2
HLA, HUB, R_INF,
Data type: Integer16
Dynamic index: -
Function diagram: -
S_INF, SERVO,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
SERVO_AC, TB30,
TM120, TM150,
Not for motor type: -
Scaling: -
Expert list: 1
TM15DI_DO, TM17,
Min:
Max:
Factory setting:
VECTOR, VECTOR_AC
0
2
1
p0105
Activate/deactivate drive object / DO act/deact
TM15, TM31, TM41
Can be changed: T
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
1
p0105
Activate/deactivate drive object / DO act/deact
TM54F_MA, TM54F_SL Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
803
SINAMICS parameters
3.2 SINAMICS parameters
r0106
Drive object active/inactive / DO act/inact
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 2
CU_S_AC_DP,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S_AC_PN,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, ENC,
Not for motor type: -
Scaling: -
Expert list: 1
HLA, HUB, R_INF,
Min:
Max:
Factory setting:
S_INF, SERVO,
0
1
-
SERVO_AC, TB30,
TM120, TM15, TM150,
TM15DI_DO, TM17,
TM31, TM41, VECTOR,
VECTOR_AC
p0107[0...n]
Drive object type / DO type
CU_S_AC_DP,
Can be changed: C1(2)
Calculated: -
Access level: 2
CU_S_AC_PN
Data type: Integer16
Dynamic index: r0095
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
312
0
p0107[0...n]
Drive object type / DO type
CU_S120_DP,
Can be changed: C1(2)
Calculated: -
Access level: 2
CU_S120_PN
Data type: Integer16
Dynamic index: r0095
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
300
0
r0107
Drive object type / DO type
HLA
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
70
70
-
r0107
Drive object type / DO type
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
11
11
-
Machine data and parameters
804
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0107
Drive object type / DO type
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
12
12
-
r0107
Drive object type / DO type
A_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10
10
-
r0107
Drive object type / DO type
B_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
30
30
-
r0107
Drive object type / DO type
R_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
21
21
-
r0107
Drive object type / DO type
S_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
20
20
-
r0107
Drive object type / DO type
TM120
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
207
207
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
805
SINAMICS parameters
3.2 SINAMICS parameters
r0107
Drive object type / DO type
TM15
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
203
203
-
r0107
Drive object type / DO type
TM150
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
208
208
-
r0107
Drive object type / DO type
TM15DI_DO
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
204
204
-
r0107
Drive object type / DO type
TM17
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
202
202
-
r0107
Drive object type / DO type
TM31
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
200
200
-
r0107
Drive object type / DO type
TM41
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
201
201
-
Machine data and parameters
806
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0107
Drive object type / DO type
TB30
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
100
100
-
r0107
Drive object type / DO type
TM54F_MA
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
205
205
-
r0107
Drive object type / DO type
TM54F_SL
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
206
206
-
r0107
Drive object type / DO type
ENC
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
300
300
-
r0107
Drive object type / DO type
HUB
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
150
150
-
p0108[0...n]
Drive objects function module / DO fct_mod
CU_S_AC_DP,
Can be changed: C1(2)
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: r0095
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
807
SINAMICS parameters
3.2 SINAMICS parameters
r0108
Drive objects function module / DO fct_mod
TB30, TM120, TM150,
Can be changed: -
Calculated: -
Access level: 2
TM15DI_DO, TM31,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
TM41
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0108
Drive objects function module / DO fct_mod
HLA
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0108
Drive objects function module / DO fct_mod
SERVO
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0108
Drive objects function module / DO fct_mod
SERVO_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0108
Drive objects function module / DO fct_mod
VECTOR
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0108
Drive objects function module / DO fct_mod
VECTOR_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
808
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0108
Drive objects function module / DO fct_mod
A_INF, R_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0108
Drive objects function module / DO fct_mod
B_INF, S_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0108
Drive objects function module / DO fct_mod
ENC
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0110[0...2]
Basic sampling times / t_basis
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [µs]
- [µs]
- [µs]
r0111
Basic sampling time selection / t_basis sel
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S_AC_PN,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, HLA,
Not for motor type: -
Scaling: -
Expert list: 1
R_INF, S_INF, SERVO,
Min:
Max:
Factory setting:
SERVO_AC, VECTOR,
-
-
-
VECTOR_AC
p0112
Sampling times pre-setting p0115 / t_samp for p0115
A_INF, B_INF, HLA,
Can be changed: C1(3)
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Integer16
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
5
3
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
809
SINAMICS parameters
3.2 SINAMICS parameters
p0113
Minimum pulse frequency, selection / f_puls min sel
SERVO, SERVO_AC
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
2.000 [kHz]
4.000 [kHz]
4.000 [kHz]
p0113
Minimum pulse frequency, selection / f_puls min sel
SERVO (Dig IO)
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
4.000 [kHz]
4.000 [kHz]
4.000 [kHz]
p0113
Minimum pulse frequency, selection / f_puls min sel
VECTOR, VECTOR_AC
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.000 [kHz]
4.000 [kHz]
2.000 [kHz]
r0114[0...9]
Minimum pulse frequency recommended / f_puls min recom
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kHz]
- [kHz]
- [kHz]
p0115[0]
Sampling time for supplementary functions / t_samp suppl_fct
CU_S_AC_DP,
Can be changed: C1(3)
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
16000.00 [µs]
4000.00 [µs]
Machine data and parameters
810
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0115[0...6]
Sampling times for internal control loops / t_samp int ctrl
HLA
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
16000.00 [µs]
[0] 125.00 [µs]
[1] 125.00 [µs]
[2] 125.00 [µs]
[3] 4000.00 [µs]
[4] 1000.00 [µs]
[5] 4000.00 [µs]
[6] 4000.00 [µs]
p0115[0...6]
Sampling times for internal control loops / t_samp int ctrl
A_INF, B_INF, R_INF,
Can be changed: C1(3)
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
16000.00 [µs]
[0] 125.00 [µs]
[1] 125.00 [µs]
[2] 125.00 [µs]
[3] 4000.00 [µs]
[4] 1000.00 [µs]
[5] 4000.00 [µs]
[6] 4000.00 [µs]
p0115[0...6]
Sampling times for internal control loops / t_samp int ctrl
SERVO (Lin),
Can be changed: C1(3)
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
16000.00 [µs]
[0] 125.00 [µs]
[1] 125.00 [µs]
[2] 125.00 [µs]
[3] 4000.00 [µs]
[4] 1000.00 [µs]
[5] 4000.00 [µs]
[6] 4000.00 [µs]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
811
SINAMICS parameters
3.2 SINAMICS parameters
p0115[0...6]
Sampling times for internal control loops / t_samp int ctrl
VECTOR, VECTOR_AC
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
16000.00 [µs]
[0] 250.00 [µs]
[1] 1000.00 [µs]
[2] 1000.00 [µs]
[3] 1000.00 [µs]
[4] 2000.00 [µs]
[5] 4000.00 [µs]
[6] 4000.00 [µs]
p0115[0]
Sampling time for supplementary functions / t_samp suppl_fct
TM120
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
16000.00 [µs]
4000.00 [µs]
p0115[0]
Sampling time for supplementary functions / t_samp suppl_fct
TB30, TM150,
Can be changed: C1(3)
Calculated: -
Access level: 3
TM15DI_DO, TM31
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
16000.00 [µs]
4000.00 [µs]
p0115[0]
Sampling time for supplementary functions / t_samp suppl_fct
TM41
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
16000.00 [µs]
4000.00 [µs]
p0115[0]
Sampling time for speed detection / t_samp n_det
ENC
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
125.00 [µs]
500.00 [µs]
125.00 [µs]
Machine data and parameters
812
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0116[0...1]
Drive object clock cycle recommended / DO_clock recom
A_INF, B_INF,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_DP,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
CU_S_AC_PN,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
CU_S120_DP,
CU_S120_PN, HLA,
Not for motor type: -
Scaling: -
Expert list: 1
R_INF, S_INF, SERVO,
Min:
Max:
Factory setting:
SERVO_AC, TB30,
- [µs]
- [µs]
- [µs]
TM15, TM15DI_DO,
TM17, TM31, TM41,
VECTOR, VECTOR_AC
p0117
Current controller computing dead time mode / I_ctrl t_dead mode
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Integer16
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
6
6
p0118
Current controller computing dead time / I_ctrl t_dead
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_CON Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
2000.00 [µs]
0.00 [µs]
p0118
Current controller computing dead time / I_ctrl t_dead
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 4
R_INF, S_INF, VECTOR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
2000.00 [µs]
0.00 [µs]
p0120
Number of valve data sets (PDS) / PDS count
HLA
Can be changed: C1(3), C2(15)
Calculated: -
Access level: 2
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
1
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
813
SINAMICS parameters
3.2 SINAMICS parameters
p0120
Number of Power unit Data Sets (PDS) / PDS count
A_INF, B_INF, R_INF,
Can be changed: C1(3), C2(15)
Calculated: -
Access level: 2
S_INF, SERVO,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
SERVO_AC, TM41,
P-Group: Data sets
Unit group: -
Unit selection: -
VECTOR, VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
8
1
p0120
Number of Power unit Data Sets (PDS) / PDS count
ENC
Can be changed: C1(3), C2(15)
Calculated: -
Access level: 8
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
8
1
p0121[0...n]
Power unit component number / PU comp_no
A_INF, B_INF, HLA,
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned8
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Data sets
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
199
0
p0124[0...n]
Main component detection using LED / M_comp detect LED
CU_S_AC_DP,
Can be changed: T, U
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: r0095
Function diagram: -
CU_S120_DP,
P-Group: Converter
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0124[0...n]
Power unit detection via LED / PU detection LED
A_INF, B_INF, HLA,
Can be changed: T, U
Calculated: -
Access level: 2
R_INF, S_INF, SERVO,
Data type: Unsigned8
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Converter
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0125[0...n]
Activate/deactivate power unit components / PU_comp act/deact
A_INF, B_INF, HLA,
Can be changed: C1(4), T
Calculated: -
Access level: 2
R_INF, S_INF, SERVO,
Data type: Integer16
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Data sets
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
1
Machine data and parameters
814
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0126[0...n]
Power unit components active/inactive / PU comp act/inact
A_INF, B_INF, HLA,
Can be changed: -
Calculated: -
Access level: 2
R_INF, S_INF, SERVO,
Data type: Integer16
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Data sets
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
-
r0127[0...n]
Power unit EEPROM data version / PU EEPROM version
A_INF, B_INF, HLA,
Can be changed: -
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Converter
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0128[0...n]
Power unit firmware version / PU FW version
A_INF, B_INF, HLA,
Can be changed: -
Calculated: -
Access level: 3
R_INF, S_INF, SERVO,
Data type: Unsigned32
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Converter
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0130
Number of Motor Data Sets (MDS) / MDS count
HLA
Can be changed: C1(3), C2(15)
Calculated: -
Access level: 2
Data type: Unsigned8
Dynamic index: -
Function diagram: 8575
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
1
1
p0130
Number of Motor Data Sets (MDS) / MDS count
SERVO, SERVO_AC,
Can be changed: C1(3), C2(15)
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned8
Dynamic index: -
Function diagram: 8575
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
16
1
p0131[0...n]
Motor component number / Mot comp_no
HLA, SERVO,
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: MDS, p0130
Function diagram: -
VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
199
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
815
SINAMICS parameters
3.2 SINAMICS parameters
p0133[0...n]
Motor configuration / Motor config
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p0139[0...2]
Copy Motor Data Set MDS / Copy MDS
SERVO, SERVO_AC,
Can be changed: C2(15)
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned8
Dynamic index: -
Function diagram: 8575
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
31
0
p0140
Number of Encoder Data Sets (EDS) / EDS count
HLA, SERVO,
Can be changed: C1(3), C2(15)
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: -
Function diagram: 8570
VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
16
1
p0140
Number of VSM data sets / VSM count
A_INF, R_INF, S_INF
Can be changed: C1(3), C2(15)
Calculated: -
Access level: 4
Data type: Unsigned8
Dynamic index: -
Function diagram: 8570
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
8
1
p0140
Number of Encoder Data Sets (EDS) / EDS count
ENC
Can be changed: C1(3), C2(15)
Calculated: -
Access level: 2
Data type: Unsigned8
Dynamic index: -
Function diagram: 8570
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
1
1
p0141[0...n]
Encoder interface (Sensor Module) component number / Enc_intf comp_no
ENC, HLA, SERVO,
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: EDS, p0140
Function diagram: 4704, 8570
VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
199
0
Machine data and parameters
816
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0141[0...n]
VSM component number / VSM comp_no
A_INF, R_INF, S_INF
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 4
Data type: Unsigned8
Dynamic index: p0140
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
199
0
p0142[0...n]
Encoder component number / Encoder comp_no
ENC, HLA, SERVO,
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: EDS, p0140
Function diagram: 4704
VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
199
0
p0144[0...n]
Sensor Module detection via LED / SM detection LED
ENC, HLA, SERVO,
Can be changed: T, U
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0144[0...n]
Voltage Sensing Module detection via LED / VSM detection LED
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: p0140
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0145[0...n]
Activate/deactivate encoder interface / Enc_intf act/deact
ENC, HLA, SERVO,
Can be changed: C1(4), T, U
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
1
p0145[0...n]
Voltage Sensing Module activate/deactivate / VSM act/deact
A_INF, R_INF, S_INF
Can be changed: C1(4), T
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: p0140
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
817
SINAMICS parameters
3.2 SINAMICS parameters
r0146[0...n]
Encoder interface active/inactive / Enc_intf act/deact
ENC, HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 2
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
-
r0146[0...n]
Voltage Sensing Module active/inactive / VSM act/inact
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: p0140
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
-
r0147[0...n]
Sensor Module EEPROM data version / SM EEPROM version
ENC, HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0147[0...n]
Voltage Sensing Module EEPROM data version / VSM EEPROM version
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: p0140
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0148[0...n]
Sensor Module firmware version / SM FW version
ENC, HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0148[0...n]
Voltage Sensing Module firmware version / VSM FW version
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: p0140
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
818
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0150
Number of VSM data sets / VSM dat_sets qty
VECTOR, VECTOR_AC
Can be changed: C1(3), C2(15)
Calculated: -
Access level: 4
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
2
1
p0150
VSM2 data sets selection / VSM2 dat_sets qty
A_INF, R_INF, S_INF
Can be changed: C1(3), C2(15)
Calculated: -
Access level: 4
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
2
1
p0151[0...n]
Voltage Sensing Module component number / VSM comp_no
VECTOR, VECTOR_AC
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: p0150
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
199
0
p0151[0...n]
Voltage Sensing Module 2 component number / VSM2 comp_no
A_INF, R_INF, S_INF
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 4
Data type: Unsigned8
Dynamic index: p0150
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
199
0
p0151
Terminal Module component number / TM comp_no
TM120, TM15, TM150,
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 3
TM15DI_DO, TM17,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
TM31, TM41,
P-Group: Data sets
Unit group: -
Unit selection: -
TM54F_MA, TM54F_SL
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
199
0
p0151[0...1]
DRIVE-CLiQ Hub Module component number / Hub comp_no
HUB
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
199
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
819
SINAMICS parameters
3.2 SINAMICS parameters
p0154[0...n]
Voltage Sensing Module detection via LED / VSM detection LED
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: Unsigned8
Dynamic index: p0150
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
1
0
p0154[0...n]
Voltage Sensing Module 2 detection via LED / VSM2 detection LED
A_INF, R_INF, S_INF
Can be changed: T, U
Calculated: -
Access level: 4
Data type: Unsigned8
Dynamic index: p0150
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0154
Terminal Module detection via LED / TM detection LED
TM120, TM15, TM150,
Can be changed: T, U
Calculated: -
Access level: 2
TM15DI_DO, TM17,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
TM31, TM41,
P-Group: Terminals
Unit group: -
Unit selection: -
TM54F_MA, TM54F_SL
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0154
DRIVE-CLiQ Hub Module detection via LED / Hub detection LED
HUB
Can be changed: T, U
Calculated: -
Access level: 2
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0155[0...n]
Voltage Sensing Module activate/deactivate / VSM act/deact
VECTOR, VECTOR_AC
Can be changed: C1(4), T
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: p0150
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
1
p0155[0...n]
Voltage Sensing Module 2 activate/deactivate / VSM2 act/deact
A_INF, R_INF, S_INF
Can be changed: C1(4), T
Calculated: -
Access level: 4
Data type: Integer16
Dynamic index: p0150
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
1
Machine data and parameters
820
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0155[0...1]
Activate/deactivate DRIVE-CLiQ Module Hub / Hub act/deact
HUB
Can be changed: C1(4), T
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
1
r0156[0...n]
Voltage Sensing Module active/inactive / VSM act/inact
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: p0150
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
-
r0156[0...n]
Voltage Sensing Module 2 active/inactive / VSM2 act/inact
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 4
Data type: Integer16
Dynamic index: p0150
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
-
r0156[0...1]
DRIVE-CLiQ Hub Module active/inactive / Hub act/inact
HUB
Can be changed: -
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
-
r0157[0...n]
Voltage Sensing Module EEPROM data version / VSM EEPROM version
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: p0150
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0157[0...n]
Voltage Sensing Module 2 EEPROM data version / VSM2 EEPROM vers
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned32
Dynamic index: p0150
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
821
SINAMICS parameters
3.2 SINAMICS parameters
r0157
Terminal Module EEPROM data version / TM EEPROM version
TM120, TM15, TM150,
Can be changed: -
Calculated: -
Access level: 3
TM15DI_DO, TM17,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
TM31, TM41,
P-Group: Terminals
Unit group: -
Unit selection: -
TM54F_MA, TM54F_SL
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0157
DRIVE-CLiQ Hub Module EEPROM data version / Hub EEPROM version
HUB
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0158[0...n]
Voltage Sensing Module firmware version / VSM FW version
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: p0150
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0158[0...n]
Voltage Sensing Module 2 firmware version / VSM2 FW version
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned32
Dynamic index: p0150
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0158
Terminal Module firmware version / TM FW version
TM120, TM15, TM150,
Can be changed: -
Calculated: -
Access level: 3
TM15DI_DO, TM17,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
TM31, TM41,
P-Group: Terminals
Unit group: -
Unit selection: -
TM54F_MA, TM54F_SL
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0158
DRIVE-CLiQ Hub Module firmware version / Hub FW version
HUB
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
822
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0161
Valve component number / Valve comp_no
HLA
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
199
0
p0161
HF Damping Module component number / HF Damp comp_no
SERVO, SERVO_AC
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 4
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
199
0
p0161
Option board component number / Opt board comp_no
TB30
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 4
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
199
0
p0162
HF Choke Module component number / HF Choke comp_no
SERVO, SERVO_AC
Can be changed: C1(4)
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Terminals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
199
0
p0165
Activate/deactivate filter module / FM act/deact
SERVO, SERVO_AC
Can be changed: C1(4), T
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
1
r0166
Filter module active/inactive / FM act/inact
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
823
SINAMICS parameters
3.2 SINAMICS parameters
p0170
Number of Command Data Sets (CDS) / CDS count
HLA, TM41
Can be changed: C1(3)
Calculated: -
Access level: 2
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
1
1
p0170
Number of Command Data Sets (CDS) / CDS count
A_INF, B_INF, R_INF,
Can be changed: C1(3)
Calculated: -
Access level: 2
S_INF, SERVO,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
SERVO_AC
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
2
1
p0170
Number of Command Data Sets (CDS) / CDS count
VECTOR, VECTOR_AC
Can be changed: C1(3)
Calculated: -
Access level: 2
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
2
4
2
p0170
Number of Command Data Sets (CDS) / CDS count
ENC
Can be changed: C1(3)
Calculated: -
Access level: 8
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Commands
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
1
1
p0171[0...n]
Drive objects function module 1 / DO fct_mod 1
CU_S_AC_DP,
Can be changed: C1(2)
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: r0095
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
r0171
Drive objects function module 1 / DO fct_mod 1
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
824
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0171
Drive objects function module 1 / DO fct_mod 1
A_INF, B_INF, ENC,
Can be changed: -
Calculated: -
Access level: 2
HLA, R_INF, S_INF,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
TB30, TM120, TM150,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
TM15DI_DO, TM31,
TM41, VECTOR,
Not for motor type: -
Scaling: -
Expert list: 1
VECTOR_AC
Min:
Max:
Factory setting:
-
-
-
p0172[0...n]
Drive objects function module 2 / DO fct_mod 2
CU_S_AC_DP,
Can be changed: C1(2)
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: r0095
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
r0172
Drive objects function module 2 / DO fct_mod 2
A_INF, B_INF, ENC,
Can be changed: -
Calculated: -
Access level: 2
HLA, R_INF, S_INF,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO, SERVO_AC,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
TB30, TM120, TM150,
TM15DI_DO, TM31,
Not for motor type: -
Scaling: -
Expert list: 1
TM41, VECTOR,
Min:
Max:
Factory setting:
VECTOR_AC
-
-
-
p0173[0...n]
Drive objects function module 3 / DO fct_mod 3
CU_S_AC_DP,
Can be changed: C1(2)
Calculated: -
Access level: 2
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: r0095
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
r0173
Drive objects function module 3 / DO fct_mod 3
A_INF, B_INF, ENC,
Can be changed: -
Calculated: -
Access level: 2
HLA, R_INF, S_INF,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO, SERVO_AC,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
TB30, TM120, TM150,
TM15DI_DO, TM31,
Not for motor type: -
Scaling: -
Expert list: 1
TM41, VECTOR,
Min:
Max:
Factory setting:
VECTOR_AC
-
-
-
p0180
Number of Drive Data Sets (DDS) / DDS count
HLA, SERVO,
Can be changed: C1(3), C2(15)
Calculated: -
Access level: 2
SERVO_AC, TM41,
Data type: Unsigned8
Dynamic index: -
Function diagram: 8565
VECTOR, VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
32
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
825
SINAMICS parameters
3.2 SINAMICS parameters
p0185[0...n]
Power unit Data Set (PDS) number / PDS number
HLA, SERVO,
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 8
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: DDS, p0180
Function diagram: -
VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
99
0
p0186[0...n]
Motor Data Sets (MDS) number / MDS number
HLA, SERVO,
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: DDS, p0180
Function diagram: 8575
VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
15
0
p0187[0...n]
Encoder 1 encoder data set number / Enc 1 EDS number
SERVO, SERVO_AC
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: DDS, p0180
Function diagram: 4700, 8570
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
99
99
p0187[0...n]
Encoder 1 encoder data set number / Enc 1 EDS number
HLA, VECTOR,
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 3
VECTOR_AC
Data type: Unsigned8
Dynamic index: DDS, p0180
Function diagram: 4700, 8570
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
99
99
p0188[0...n]
Encoder 2 encoder data set number / Enc 2 EDS number
HLA, SERVO,
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: DDS, p0180
Function diagram: 4700, 8570
VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
99
99
p0189[0...n]
Encoder 3 encoder data set number / Enc 3 EDS number
HLA, SERVO,
Can be changed: C1(4), C2(15)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: DDS, p0180
Function diagram: 4700, 8570
VECTOR_AC
P-Group: Data sets
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
99
99
Machine data and parameters
826
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0192
Power unit firmware properties 1 / PU FW properties 1
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0192
Power unit firmware properties 1 / PU FW properties 1
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0193
Power unit firmware properties 2 / PU FW properties 2
HLA
Can be changed: -
Calculated: -
Access level: 8
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-
-
-
r0193
Power unit firmware properties 2 / PU FW properties 2
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Converter
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0194[0...n]
VSM properties / VSM properties
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned32
Dynamic index: p0150
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0194[0...n]
VSM properties / VSM properties
A_INF, R_INF, S_INF
Can be changed: -
Calculated: -
Access level: 4
Data type: Unsigned32
Dynamic index: p0140
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
827
SINAMICS parameters
3.2 SINAMICS parameters
r0196[0...255]
Topology component status / Top comp stat
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 3
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0197[0...1]
Bootloader version / Bootloader vers
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0198[0...2]
BIOS/EEPROM data version / BIOS/EEPROM vers
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: Closed-loop control
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0199[0...24]
Drive object name / DO name
All objects
Can be changed: C1
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
r0200[0...n]
Power unit code number actual / PU code no act
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: Unsigned16
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Converter
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0201[0...n]
Power unit code number / PU code no
SERVO, SERVO_AC,
Can be changed: C2(2)
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
Machine data and parameters
828
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0201[0...n]
Power unit code number / PU code no
A_INF, B_INF, R_INF,
Can be changed: C2(2)
Calculated: -
Access level: 3
S_INF
Data type: Unsigned16
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
r0203[0...15]
Firmware package name / FW pkg name
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 4
CU_S_AC_PN,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0203[0...n]
Actual power unit type / PU actual type
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: Integer16
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Converter
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
2
400
-
r0204
Power unit hardware properties / PU HW properties
CU_S_AC_DP,
Can be changed: -
Calculated: -
Access level: 8
CU_S_AC_PN,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
CU_S120_DP,
P-Group: -
Unit group: -
Unit selection: -
CU_S120_PN
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0204[0...n]
Power unit hardware properties / PU HW properties
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: Unsigned32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0204[0...n]
Power unit hardware properties / PU HW properties
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF
Data type: Unsigned32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
829

 

 

 

 

 

 

 