SINAMICS parameters
3.2 SINAMICS parameters
p0205[0...n]
Valve rated voltage / Valve Un
HLA
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.500 [V]
15.000 [V]
10.000 [V]
p0205
Power unit application / PU application
A_INF, B_INF, R_INF,
Can be changed: C2(1, 2)
Calculated: -
Access level: 8
S_INF, SERVO,
Data type: Integer16
Dynamic index: -
Function diagram: -
SERVO_AC
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
7
6
p0205
Power unit application / PU application
VECTOR, VECTOR_AC
Can be changed: C2(1, 2)
Calculated: -
Access level: 2
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
7
6
p0206[0...n]
Valve transition point flow rate / Valve trans flow
HLA
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.2 [%]
95.0 [%]
10.0 [%]
r0206[0...4]
Rated power unit power / PU P_rated
A_INF, B_INF, S_INF,
Can be changed: -
Calculated: -
Access level: 2
SERVO, SERVO_AC,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR, VECTOR_AC
P-Group: Converter
Unit group: 14_6
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r0206[0...4]
Rated power unit power / PU P_rated
R_INF
Can be changed: -
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: 14_6
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
Machine data and parameters
830
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0207[0...n]
Valve transition point voltage / Valve trans U
HLA
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.2 [%]
95.0 [%]
10.0 [%]
r0207[0...4]
Rated power unit current / PU PI_rated
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8021
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0207[0...4]
Rated power unit current / PU PI_rated
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 2
S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8021
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
p0208[0...n]
Valve rated flow rate / Valve Vn
HLA
Can be changed: C2(1, 2)
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [ltr/min]
1000.000 [ltr/min]
0.000 [ltr/min]
r0208
Rated power unit line supply voltage / PU U_rated
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 2
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Converter
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
p0209[0...n]
Valve rated pressure drop / Valve Pn
HLA
Can be changed: C2(1, 2)
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.0 [bar]
300.0 [bar]
35.0 [bar]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
831
SINAMICS parameters
3.2 SINAMICS parameters
r0209[0...4]
Power unit maximum current / PU I_max
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 2
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8750, 8850,
SERVO_AC, VECTOR,
8950
VECTOR_AC
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
p0210
Drive unit line supply voltage / U_connect
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [V]
63000 [V]
600 [V]
p0210
Drive unit line supply voltage / U_connect
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [V]
63000 [V]
600 [V]
p0210
Drive unit line supply voltage / U_connect
A_INF, R_INF, S_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8860, 8960
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
70 [Vrms]
1000 [Vrms]
400 [Vrms]
p0210
Drive unit line supply voltage / U_connect
B_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8760
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
70 [Vrms]
1000 [Vrms]
400 [Vrms]
p0211[0...n]
Valve, flow rate ratio A to B side / Flowrate_ratio A/B
HLA
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.500
2.000
1.000
Machine data and parameters
832
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0211
Rated line frequency / Rated line freq
VECTOR (n/M),
Can be changed: T
Calculated: -
Access level: 4
VECTOR_AC (n/M)
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10 [Hz]
100 [Hz]
60 [Hz]
p0211
Rated line frequency / Rated line freq
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8864, 8964
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10 [Hz]
100 [Hz]
50 [Hz]
p0212
Power unit configuration / PU config
SERVO, SERVO_AC
Can be changed: C2(2)
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p0212
Power unit configuration / PU config
VECTOR, VECTOR_AC
Can be changed: C2(2)
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 bin
p0212
Power unit configuration / PU config
VECTOR (n/M),
Can be changed: C2(2)
Calculated: -
Access level: 3
VECTOR_AC (n/M)
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 bin
p0212
Power unit configuration / PU config
A_INF, R_INF, S_INF
Can be changed: C2(2)
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 bin
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
833
SINAMICS parameters
3.2 SINAMICS parameters
p0212
Power unit configuration / PU config
B_INF
Can be changed: C2(2)
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 bin
p0213
BI: 1-phase emergency operation activation signal source / Emerg op act s_s
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 8
S_INF, SERVO,
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Commands
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0216[0...n]
Valve natural frequency / Valve fn
HLA
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: 4966
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.0 [Hz]
1000.0 [Hz]
150.0 [Hz]
r0216[0...7]
Bake voltage level / Brake U_level
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0216[0...7]
Bake voltage level / Brake U_level
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
p0217[0...n]
Valve damping / Valve D
HLA
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.400
1.000
0.800
Machine data and parameters
834
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0218[0...n]
Cylinder safety configuration / Cyl safety config
HLA
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0111 bin
p0220
Hydraulic oil modulus of elasticity / Hydr_oil e_module
HLA
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1000.0 [bar]
21000.0 [bar]
11000.0 [bar]
p0220[0...1]
Infeed line filter type / INF line filt type
A_INF, R_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 8950
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
119
0
p0220[0...1]
Infeed line filter type / INF line filt type
S_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: 8950
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
119
0
p0221
System pressure / p_system
HLA
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [bar]
10000.0 [bar]
0.0 [bar]
p0221[0...1]
Infeed filter capacitance / INF C_filter
A_INF, R_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8950
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µF]
100000.00 [µF]
0.00 [µF]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
835
SINAMICS parameters
3.2 SINAMICS parameters
p0221[0...1]
Infeed filter capacitance / INF C_filter
S_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8950
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [µF]
100000.00 [µF]
0.00 [µF]
p0222[0...n]
Valve precontrol pressure / Valve p_prectrl
HLA
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [bar]
350.0 [bar]
0.0 [bar]
p0222[0...1]
Infeed filter resistance / INF R_filter
A_INF, R_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [ohm]
100.00000 [ohm]
0.00000 [ohm]
p0222[0...1]
Infeed filter resistance / INF R_filter
S_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00000 [ohm]
100.00000 [ohm]
0.00000 [ohm]
p0223
Infeed inductance between filter and power unit / INF L filter/PU
A_INF, R_INF, S_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8850, 8950
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001 [mH]
1000.000 [mH]
2.100 [mH]
p0224
Infeed resistance between filter and power unit / INF R filter/PU
A_INF, R_INF, S_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8850, 8950
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [ohm]
100.00000 [ohm]
0.00100 [ohm]
Machine data and parameters
836
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0225
Infeed inductance between line supply and filter / INF L line/filter
A_INF, R_INF, S_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8850, 8950
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.001 [mH]
1000.000 [mH]
0.001 [mH]
p0226
Infeed resistance between line supply and filter / INF R line/filter
A_INF, R_INF, S_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8850, 8950
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [ohm]
100.00 [ohm]
0.00 [ohm]
p0227
Infeed DC link capacitance, power unit / INF C
A_INF, R_INF, S_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8850, 8950
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.20 [mF]
1000.00 [mF]
1.00 [mF]
p0228
Infeed filter inductance line side / INF L_filt L side
A_INF, R_INF, S_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8850, 8950
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [mH]
1000.000 [mH]
0.000 [mH]
p0230[0...n]
Manipulated variable inhibit time / Manip var t_inhib
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
1000 [ms]
300 [ms]
p0230
Drive filter type motor side / Drv filt type mot
SERVO, SERVO_AC
Can be changed: C2(1, 2)
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
3
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
837
SINAMICS parameters
3.2 SINAMICS parameters
p0230
Drive filter type motor side / Drv filt type mot
VECTOR, VECTOR_AC
Can be changed: C2(1, 2)
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4
0
p0231[0...n]
Power enable inhibit time / Pow_enab t_inhib
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
300 [ms]
100 [ms]
r0231[0...1]
Power cable length maximum / Cable length max
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [m]
- [m]
- [m]
r0231[0...1]
Power cable length maximum / Cable length max
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 8
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [m]
- [m]
- [m]
p0232[0...n]
Valve monitoring time / Valve t_mon
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [ms]
1000 [ms]
50 [ms]
p0233
Power unit motor reactor / PU mot reactor
SERVO, SERVO_AC
Can be changed: C2(1), T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [mH]
1000.000 [mH]
0.000 [mH]
Machine data and parameters
838
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0233
Power unit motor reactor / PU mot reactor
VECTOR, VECTOR_AC
Can be changed: C2(1), T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [mH]
1000.000 [mH]
0.000 [mH]
p0234
Power unit sine-wave filter capacitance / PU sine filter C
SERVO, SERVO_AC
Can be changed: C2(1), T, U
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [µF]
2000.000 [µF]
0.000 [µF]
p0234
Power unit sine-wave filter capacitance / PU sine filter C
VECTOR, VECTOR_AC
Can be changed: C2(1), T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [µF]
2000.000 [µF]
0.000 [µF]
p0235
Motor reactor in series number / L_mot in SeriesQty
SERVO, SERVO_AC
Can be changed: C2(1, 2)
Calculated: -
Access level: 8
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1
3
1
p0235
Motor reactor in series number / L_mot in SeriesQty
VECTOR, VECTOR_AC
Can be changed: C2(1, 2)
Calculated: -
Access level: 1
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
3
1
r0238
Internal power unit resistance / PU R internal
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
839
SINAMICS parameters
3.2 SINAMICS parameters
p0240[0...n]
Pressure sensor A reference value at 10 V / Sensor A ref 10V
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.0 [bar]
1000.0 [bar]
200.0 [bar]
p0241[0...n]
Pressure sensor A offset correction / Sensor A offset
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-5000.000 [bar]
5000.000 [bar]
0.000 [bar]
p0242[0...n]
Pressure sensor B reference value at 10 V / Sensor B ref 10V
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.0 [bar]
1000.0 [bar]
200.0 [bar]
p0243[0...n]
Pressure sensor B offset correction / Sensor B offset
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-5000.000 [bar]
5000.000 [bar]
0.000 [bar]
p0244[0...n]
Pressure sensor P reference value at 10 V / Sensor P ref 10V
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50.0 [bar]
1000.0 [bar]
200.0 [bar]
p0245[0...n]
Pressure sensor P offset correction / Sensor P offs_corr
HLA
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-5000.000 [bar]
5000.000 [bar]
0.000 [bar]
Machine data and parameters
840
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0246
CI: System pressure external / Sys pressure ext
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0247
Voltage measurement configuration / U_mes config
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 bin
p0249
Power unit cooling type / PU cool type
S_INF, SERVO,
Can be changed: C2(1, 2)
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0249
Power unit cooling type / PU cool type
A_INF, R_INF
Can be changed: C2(1, 2)
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
1
0
p0251[0...n]
Power unit heat sink fan operating hours counter / PU fan t_op
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: Unsigned32
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Modulation
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [h]
4294967295 [h]
0 [h]
p0252
Power unit heat sink fan operating time maximum / PU fan t_op max
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 4
S_INF, SERVO,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Modulation
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [h]
500000 [h]
40000 [h]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
841
SINAMICS parameters
3.2 SINAMICS parameters
p0254[0...n]
Operating hours counter power unit fan inside the converter / PU inner fan t_op
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: Unsigned32
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Modulation
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [h]
4294967295 [h]
0 [h]
p0255[0...7]
Power unit contactor monitoring time / PU cont t_mon
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Modulation
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1 [ms]
65535 [ms]
[0] 0 [ms]
[1] 0 [ms]
[2] -1 [ms]
[3] -1 [ms]
[4...7] 0 [ms]
r0256.0...31
CO/BO: Power unit contactor inputs/outputs status / PU cont IO stat
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: 9814
VECTOR_AC
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0260
Cooling unit starting time 1 / RKA start time 1
A_INF (Cool_unit),
Can be changed: T, U
Calculated: -
Access level: 3
B_INF (Cool_unit),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9794, 9795
R_INF (Cool_unit),
P-Group: Converter
Unit group: -
Unit selection: -
S_INF (Cool_unit),
SERVO (Cool_unit),
Not for motor type: -
Scaling: -
Expert list: 1
SERVO_AC (Cool_unit),
Min:
Max:
Factory setting:
VECTOR (Cool_unit),
0.0 [s]
60.0 [s]
5.0 [s]
VECTOR_AC
(Cool_unit)
p0261
Cooling unit starting time 2 / RKA start time 2
A_INF (Cool_unit),
Can be changed: T, U
Calculated: -
Access level: 3
B_INF (Cool_unit),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9794, 9795
R_INF (Cool_unit),
P-Group: Converter
Unit group: -
Unit selection: -
S_INF (Cool_unit),
SERVO (Cool_unit),
Not for motor type: -
Scaling: -
Expert list: 1
SERVO_AC (Cool_unit),
Min:
Max:
Factory setting:
VECTOR (Cool_unit),
0.0 [s]
1200.0 [s]
180.0 [s]
VECTOR_AC
(Cool_unit)
Machine data and parameters
842
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0262
Cooling unit fault conductivity delay time / RKA cond t_del
A_INF (Cool_unit),
Can be changed: T, U
Calculated: -
Access level: 3
B_INF (Cool_unit),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9794, 9795
R_INF (Cool_unit),
P-Group: Converter
Unit group: -
Unit selection: -
S_INF (Cool_unit),
SERVO (Cool_unit),
Not for motor type: -
Scaling: -
Expert list: 1
SERVO_AC (Cool_unit),
Min:
Max:
Factory setting:
VECTOR (Cool_unit),
0.0 [s]
30.0 [s]
0.0 [s]
VECTOR_AC
(Cool_unit)
p0263
Cooling unit fault liquid flow delay time / RKA flow t_del
A_INF (Cool_unit),
Can be changed: T, U
Calculated: -
Access level: 3
B_INF (Cool_unit),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9794, 9795
R_INF (Cool_unit),
P-Group: Converter
Unit group: -
Unit selection: -
S_INF (Cool_unit),
SERVO (Cool_unit),
Not for motor type: -
Scaling: -
Expert list: 1
SERVO_AC (Cool_unit),
Min:
Max:
Factory setting:
VECTOR (Cool_unit),
0.0 [s]
20.0 [s]
3.0 [s]
VECTOR_AC
(Cool_unit)
p0264
Cooling unit run-on time / RKA run-on time
A_INF (Cool_unit),
Can be changed: T, U
Calculated: -
Access level: 3
B_INF (Cool_unit),
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9794, 9795
R_INF (Cool_unit),
P-Group: Converter
Unit group: -
Unit selection: -
S_INF (Cool_unit),
SERVO (Cool_unit),
Not for motor type: -
Scaling: -
Expert list: 1
SERVO_AC (Cool_unit),
Min:
Max:
Factory setting:
VECTOR (Cool_unit),
0.0 [s]
180.0 [s]
30.0 [s]
VECTOR_AC
(Cool_unit)
r0265.0...3
BO: Cooling unit control word / Cool_unit STW
A_INF (Cool_unit),
Can be changed: -
Calculated: -
Access level: 3
B_INF (Cool_unit),
Data type: Unsigned8
Dynamic index: -
Function diagram: -
R_INF (Cool_unit),
P-Group: Commands
Unit group: -
Unit selection: -
S_INF (Cool_unit),
SERVO (Cool_unit),
Not for motor type: -
Scaling: -
Expert list: 1
SERVO_AC (Cool_unit),
Min:
Max:
Factory setting:
VECTOR (Cool_unit),
-
-
-
VECTOR_AC
(Cool_unit)
p0266[0...7]
BI: Cooling unit feedback signals signal source / Cool_unit fdbk s_s
A_INF (Cool_unit),
Can be changed: T, U
Calculated: -
Access level: 3
B_INF (Cool_unit),
Data type: Unsigned32 / Binary
Dynamic index: -
Function diagram: -
R_INF (Cool_unit),
P-Group: Communications
Unit group: -
Unit selection: -
S_INF (Cool_unit),
SERVO (Cool_unit),
Not for motor type: -
Scaling: -
Expert list: 1
SERVO_AC (Cool_unit),
Min:
Max:
Factory setting:
VECTOR (Cool_unit),
-
-
1
VECTOR_AC
(Cool_unit)
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
843
SINAMICS parameters
3.2 SINAMICS parameters
r0267.0...7
BO: Cooling unit status word / Cool_unit ZSW
A_INF (Cool_unit),
Can be changed: -
Calculated: -
Access level: 3
B_INF (Cool_unit),
Data type: Unsigned16
Dynamic index: -
Function diagram: -
R_INF (Cool_unit),
P-Group: Commands
Unit group: -
Unit selection: -
S_INF (Cool_unit),
SERVO (Cool_unit),
Not for motor type: -
Scaling: -
Expert list: 1
SERVO_AC (Cool_unit),
Min:
Max:
Factory setting:
VECTOR (Cool_unit),
-
-
-
VECTOR_AC
(Cool_unit)
r0277[0...n]
Power unit heat sink fan wear counter / PU fan wear_count
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 3
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: PDS, p0120
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Modulation
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [%]
- [%]
- [%]
p0278
DC link voltage undervoltage threshold reduction / Vdc U_under red
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-80 [V]
0 [V]
0 [V]
p0278
DC link voltage undervoltage threshold reduction / Vdc U_under red
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 8
S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-80 [V]
0 [V]
0 [V]
p0279
DC link voltage offset alarm threshold / Vdc offs A thr
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 3
S_INF
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8760, 8864,
8964
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [V]
500 [V]
0 [V]
Machine data and parameters
844
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0280
DC link voltage maximum steady-state / Vdc_max stat
A_INF, R_INF
Can be changed: C2(1), T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940, 8964
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50 [V]
1500 [V]
660 [V]
p0280
DC link voltage maximum steady-state / Vdc_max stat
S_INF
Can be changed: C2(1), T
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8940, 8964
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
50 [V]
1500 [V]
660 [V]
p0281
Line supply overvoltage alarm threshold / U_l_over A thr
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8860, 8960
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
100 [%]
200 [%]
110 [%]
p0281
Line supply overvoltage alarm threshold / U_l_over A thr
B_INF
Can be changed: T
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
100 [%]
200 [%]
110 [%]
p0282
Line supply undervoltage alarm threshold / U_l_under A thr
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8860, 8960
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10 [%]
100 [%]
85 [%]
p0282
Line supply undervoltage alarm threshold / U_l_under A thr
B_INF
Can be changed: T
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
75 [%]
100 [%]
85 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
845
SINAMICS parameters
3.2 SINAMICS parameters
p0283
Line supply undervoltage shutdown (trip) threshold / U_l_under tr_thr
A_INF, R_INF, S_INF
Can be changed: C2(1), T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8860, 8960
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10 [%]
100 [%]
75 [%]
p0283
Line supply undervoltage shutdown (trip) threshold / U_l_under tr_thr
B_INF
Can be changed: C2(1), T
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
60 [%]
100 [%]
75 [%]
p0284
Line supply frequency exceeded alarm threshold / f_l_exc A thr
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8864, 8964
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
100.0 [%]
300.0 [%]
110.0 [%]
p0285
Line supply frequency undershot alarm threshold / f_l_under A thr
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8864, 8964
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
100.0 [%]
90.0 [%]
p0286[0...1]
Line supply voltage voltage step threshold / U_line U_step thr
A_INF, R_INF, S_INF
Can be changed: C2(1), T
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1 [%]
95 [%]
[0] 15 [%]
[1] 4 [%]
Machine data and parameters
846
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0287[0...1]
Ground fault monitoring shutdown threshold / Gnd flt threshold
A_INF, R_INF, S_INF,
Can be changed: T
Calculated: -
Access level: 3
SERVO, SERVO_AC,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR, VECTOR_AC
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
100.0 [%]
[0] 6.0 [%]
[1] 16.0 [%]
r0289
CO: Maximum power unit output current / PU I_outp max
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Displays, signals
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2002
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
p0290
Power unit overload response / PU overl response
SERVO, SERVO_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 8021
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
13
0
p0290
Power unit overload response / PU overl response
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: 8021
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
13
0
p0290
Power unit overload response / PU overl response
A_INF, B_INF, R_INF,
Can be changed: T
Calculated: -
Access level: 8
S_INF
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0
3
1
r0293
CO: Power unit alarm threshold model temperature / PU A_thr mod_temp
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8021
P-Group: Converter
Unit group: 21_1
Unit selection: p0505
Not for motor type: -
Scaling: p2006
Expert list: 1
Min:
Max:
Factory setting:
- [°C]
- [°C]
- [°C]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
847
SINAMICS parameters
3.2 SINAMICS parameters
p0294
Power unit alarm with I2t overload / PU I2t alarm thr
A_INF, R_INF, S_INF,
Can be changed: T, U
Calculated: -
Access level: 3
SERVO, SERVO_AC,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8021
VECTOR, VECTOR_AC
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
100.0 [%]
95.0 [%]
p0294
Power unit alarm with I2t overload / PU I2t alarm thr
B_INF
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 8021
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
100.0 [%]
95.0 [%]
p0295
Fan run-on time / Fan run-on time
A_INF, B_INF, R_INF,
Can be changed: T, U
Calculated: -
Access level: 1
S_INF, SERVO,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
SERVO_AC, VECTOR,
P-Group: Converter
Unit group: -
Unit selection: -
VECTOR_AC
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [s]
600 [s]
0 [s]
r0296
DC link voltage undervoltage threshold / Vdc U_under_thr
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0296
DC link voltage undervoltage threshold / Vdc U_under_thr
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 2
S_INF
Data type: Unsigned16
Dynamic index: -
Function diagram: 8750, 8760,
8850, 8864, 8950, 8964
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
r0297
DC link voltage overvoltage threshold / Vdc U_over_thr
A_INF, B_INF, R_INF,
Can be changed: -
Calculated: -
Access level: 2
S_INF, SERVO,
Data type: Unsigned16
Dynamic index: -
Function diagram: 8750, 8760,
SERVO_AC, VECTOR,
8850, 8864, 8950, 8964
VECTOR_AC
P-Group: Converter
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [V]
- [V]
- [V]
Machine data and parameters
848
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0300[0...n]
Motor type selection / Mot type sel
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
10100
0
p0300[0...n]
Motor type selection / Mot type sel
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: 6310
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
10001
0
p0301[0...n]
Motor code number selection / Mot code no sel
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p0301[0...n]
Motor code number selection / Mot code no sel
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p0301[0...n]
Motor code number selection / Mot code no sel
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
r0302[0...n]
Motor code number of motor with DRIVE-CLiQ / Mot code mot w DQ
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
849
SINAMICS parameters
3.2 SINAMICS parameters
r0302[0...n]
Motor code number of motor with DRIVE-CLiQ / Mot code mot w DQ
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0303[0...n]
Motor with DRIVE-CLiQ status word / Motor w DQ ZSW
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0304[0...n]
Rated motor voltage / Mot U_rated
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [Vrms]
20000 [Vrms]
0 [Vrms]
p0304[0...n]
Rated motor voltage / Mot U_rated
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6301, 6724
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [Vrms]
20000 [Vrms]
0 [Vrms]
p0305[0...n]
Rated motor current / Mot I_rated
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
p0305[0...n]
Rated motor current / Mot I_rated
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6301
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
Machine data and parameters
850
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0306[0...n]
Number of motors connected in parallel / Mot parallel qty
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: Unsigned8
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
10
1
p0306[0...n]
Number of motors connected in parallel / Mot parallel qty
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: Unsigned8
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
50
1
p0307[0...n]
Rated motor power / Mot P_rated
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 14_6
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [kW]
100000.00 [kW]
0.00 [kW]
p0307[0...n]
Rated motor power / Mot P_rated
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 14_6
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-100000.00 [kW]
100000.00 [kW]
0.00 [kW]
p0308[0...n]
Rated motor power factor / Mot cos phi rated
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000
1.000
0.000
p0308[0...n]
Rated motor power factor / Mot cos phi rated
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-0.990
1.000
0.000
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
851
SINAMICS parameters
3.2 SINAMICS parameters
p0309[0...n]
Rated motor efficiency / Mot eta_rated
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.0 [%]
99.9 [%]
0.0 [%]
p0309[0...n]
Rated motor efficiency / Mot eta_rated
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [%]
99.9 [%]
0.0 [%]
p0310[0...n]
Cylinder piston diameter / Cyl piston diam
HLA
Can be changed: C2(1, 3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [mm]
2500.0 [mm]
0.0 [mm]
p0310[0...n]
Rated motor frequency / Mot f_rated
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Hz]
3000.00 [Hz]
0.00 [Hz]
p0310[0...n]
Rated motor frequency / Mot f_rated
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6301
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [Hz]
3000.000 [Hz]
0.000 [Hz]
p0311[0...n]
Cylinder piston rod diameter A side / Cyl PistRodDiam A
HLA
Can be changed: C2(1, 3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [mm]
2400.0 [mm]
0.0 [mm]
Machine data and parameters
852
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0311[0...n]
Rated motor speed / Mot n_rated
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [rpm]
210000.0 [rpm]
0.0 [rpm]
p0311[0...n]
Rated motor velocity / Mot v_rated
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [m/min]
6000.0 [m/min]
0.0 [m/min]
p0311[0...n]
Rated motor speed / Mot n_rated
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [rpm]
210000.00 [rpm]
0.00 [rpm]
p0312[0...n]
Cylinder piston rod diameter B side / Cyl rod diam B
HLA
Can be changed: C2(1, 3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [mm]
2400.0 [mm]
0.0 [mm]
p0312[0...n]
Rated motor torque / Mot M_rated
SERVO, SERVO_AC
Can be changed: C2(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 7_4
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
1000000.00 [Nm]
0.00 [Nm]
p0312[0...n]
Rated motor force / Mot F_rated
SERVO (Lin),
Can be changed: C2(3)
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 8_4
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [N]
1000000.00 [N]
0.00 [N]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
853
SINAMICS parameters
3.2 SINAMICS parameters
p0312[0...n]
Rated motor torque / Mot M_rated
VECTOR, VECTOR_AC
Can be changed: C2(3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [Nm]
1000000.00 [Nm]
0.00 [Nm]
p0313[0...n]
Cylinder piston stroke / Cyl pist stroke
HLA
Can be changed: C2(1, 3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [mm]
6000.0 [mm]
0.0 [mm]
r0313[0...n]
CO: Motor pole pair number, actual (or calculated) / MotPolePair no act
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: MDS, p0130 Function diagram: 5300
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0313[0...n]
CO: Motor pole pair number, actual (or calculated) / MotPolePair no act
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: MDS, p0130 Function diagram: 5300
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0313[0...n]
CO: Motor pole pair number, actual (or calculated) / MotPolePair no act
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: MDS, p0130 Function diagram: 5300
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0314[0...n]
Cylinder dead volume A side / Cyl_dead vol A
HLA
Can be changed: C2(1), T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [cm³]
200000.0 [cm³]
0.0 [cm³]
Machine data and parameters
854
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0314[0...n]
Motor pole pair number / Mot PolePair no
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4000
0
p0314[0...n]
Motor pole pair number / Mot PolePair no
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4000
0
p0314[0...n]
Motor pole pair number / Mot PolePair no
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
0
p0315[0...n]
Cylinder dead volume B side / Cyl_dead vol B
HLA
Can be changed: C2(1), T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [cm³]
200000.0 [cm³]
0.0 [cm³]
p0315[0...n]
Motor pole pair width / Mot PolePair width
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.00 [mm]
1000.00 [mm]
30.00 [mm]
p0315[0...n]
Motor pole pair width / Mot PolePair width
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.00 [mm]
1000.00 [mm]
30.00 [mm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
855
SINAMICS parameters
3.2 SINAMICS parameters
p0315[0...n]
Motor pole pair width / Mot PolePair width
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
1.00 [mm]
1000.00 [mm]
30.00 [mm]
p0316[0...n]
Motor torque constant / Mot kT
SERVO, SERVO_AC
Can be changed: C2(1), T, U
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 28_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [Nm/A]
4000.000 [Nm/A]
0.000 [Nm/A]
p0316[0...n]
Motor force constant / Mot kT
SERVO (Lin),
Can be changed: C2(1), T, U
Calculated: -
Access level: 1
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 29_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [N/Arms]
150000.000 [N/Arms]
0.000 [N/Arms]
p0316[0...n]
Motor torque constant / Mot kT
VECTOR, VECTOR_AC
Can be changed: C2(1), T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 28_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [Nm/A]
400.000 [Nm/A]
0.000 [Nm/A]
p0317[0...n]
Motor voltage constant / Mot kE
SERVO, SERVO_AC
Can be changed: C2(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Vrms]
240000.0 [Vrms]
0.0 [Vrms]
p0317[0...n]
Motor voltage constant / Mot kE
SERVO (Lin),
Can be changed: C2(3)
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [Vrms s/m]
50000.0 [Vrms s/m]
0.0 [Vrms s/m]
Machine data and parameters
856
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0317[0...n]
Motor voltage constant / Mot kE
VECTOR, VECTOR_AC
Can be changed: C2(3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.0 [Vrms]
24000.0 [Vrms]
0.0 [Vrms]
p0318[0...n]
Motor stall current / Mot I_standstill
SERVO, SERVO_AC
Can be changed: C2(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8017
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
p0318[0...n]
Motor stall current / Mot I_standstill
VECTOR, VECTOR_AC
Can be changed: C2(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8017
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
p0319[0...n]
Motor stall torque / Mot M_standstill
SERVO, SERVO_AC
Can be changed: C2(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 7_4
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Nm]
100000.00 [Nm]
0.00 [Nm]
p0319[0...n]
Motor stall force / Mot F_standstill
SERVO (Lin),
Can be changed: C2(3)
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 8_4
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [N]
100000.00 [N]
0.00 [N]
p0319[0...n]
Motor stall torque / Mot M_standstill
VECTOR, VECTOR_AC
Can be changed: C2(3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [Nm]
100000.00 [Nm]
0.00 [Nm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
857
SINAMICS parameters
3.2 SINAMICS parameters
p0320[0...n]
Motor rated magnetizing current/short-circuit current / Mot I_mag_rated
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 5722
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [Arms]
5000.000 [Arms]
0.000 [Arms]
p0322[0...n]
Maximum motor speed / Mot n_max
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [rpm]
210000.0 [rpm]
0.0 [rpm]
p0322[0...n]
Motor maximum velocity / Mot v_max
SERVO (Lin, Lin,
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Spin_diag), SERVO_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
(Lin, Lin, Spin_diag)
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [m/min]
2000.0 [m/min]
0.0 [m/min]
p0322[0...n]
Maximum motor speed / Mot n_max
SERVO (Spin_diag),
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
SERVO_AC (Spin_diag)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [rpm]
260000.0 [rpm]
0.0 [rpm]
p0322[0...n]
Maximum motor speed / Mot n_max
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [rpm]
210000.0 [rpm]
0.0 [rpm]
p0323[0...n]
Maximum motor current / Mot I_max
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 5722
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
20000.00 [Arms]
0.00 [Arms]
Machine data and parameters
858
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0323[0...n]
Maximum motor current / Mot I_max
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
20000.00 [Arms]
0.00 [Arms]
p0324[0...n]
Winding maximum speed / Winding n_max
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [rpm]
210000.0 [rpm]
0.0 [rpm]
p0324[0...n]
Winding maximum velocity / Winding v_max
SERVO (Lin),
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [m/min]
1300.0 [m/min]
0.0 [m/min]
p0324[0...n]
Winding maximum speed / Winding n_max
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [rpm]
210000.0 [rpm]
0.0 [rpm]
p0325[0...n]
Motor pole position identification current 1st phase / Mot PolID I 1st Ph
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [Arms]
10000.000 [Arms]
0.000 [Arms]
p0326[0...n]
Motor stall torque correction factor / Mot M_stall_corr
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
5 [%]
300 [%]
60 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
859
SINAMICS parameters
3.2 SINAMICS parameters
p0326[0...n]
Motor stall force correction factor / Mot F_stall_corr
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
5 [%]
300 [%]
60 [%]
p0326[0...n]
Motor stall torque correction factor / Mot M_stall_corr
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
5 [%]
300 [%]
60 [%]
p0327[0...n]
Optimum motor load angle / Mot phi_load opt
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 5722, 6721
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [°]
135.0 [°]
90.0 [°]
p0328[0...n]
Motor reluctance torque constant / Mot kT_reluctance
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [mH]
1000.00 [mH]
0.00 [mH]
p0328[0...n]
Motor reluctance force constant / Mot kT_reluctance
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-1000.00 [mH]
1000.00 [mH]
0.00 [mH]
p0329[0...n]
Motor pole position identification current / Mot PolID current
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
Machine data and parameters
860
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0330[0...n]
Rated motor slip / Mot slip_rated
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
r0331[0...n]
Actual motor magnetizing current/short-circuit current / Mot I_mag_rtd act
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 5722, 6722,
6724
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Arms]
- [Arms]
- [Arms]
r0332[0...n]
Rated motor power factor / Mot cos phi rated
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0333[0...n]
Rated motor torque / Mot M_rated
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 7_4
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Nm]
- [Nm]
- [Nm]
r0333[0...n]
Rated motor force / Mot F_rated
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 8_4
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [N]
- [N]
- [N]
r0334[0...n]
Actual motor-torque constant / Mot kT act
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 28_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Nm/A]
- [Nm/A]
- [Nm/A]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
861
SINAMICS parameters
3.2 SINAMICS parameters
r0334[0...n]
Actual motor force constant / Mot kT act
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 29_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [N/Arms]
- [N/Arms]
- [N/Arms]
r0334[0...n]
Actual motor-torque constant / Mot kT act
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 28_1
Unit selection: p0100
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Nm/A]
- [Nm/A]
- [Nm/A]
p0335[0...n]
Motor cooling type / Mot cool type
SERVO, SERVO_AC,
Can be changed: C2(1), T
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
128
0
r0336[0...n]
Actual rated motor frequency / Mot f_rated act
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Hz]
- [Hz]
- [Hz]
r0337[0...n]
Rated motor EMF / Mot EMF_rated
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
r0337[0...n]
Rated motor EMF / Mot EMF_rated
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms s/m]
- [Vrms s/m]
- [Vrms s/m]
Machine data and parameters
862
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0338[0...n]
Motor limit current / Mot I_limit
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
p0338[0...n]
Motor limit current / Mot I_limit
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
r0339[0...n]
Rated motor voltage / Mot U_rated
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [Vrms]
- [Vrms]
- [Vrms]
p0340[0...n]
Automatic parameter calculation / Auto par calc
HLA
Can be changed: C2(1), T
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 bin
p0340[0...n]
Automatic calculation motor/control parameters / Calc auto par
SERVO, SERVO_AC,
Can be changed: T
Calculated: -
Access level: 2
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
5
0
p0340
Automatic calculation control parameters / Calc auto par
A_INF, R_INF, S_INF
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
863
SINAMICS parameters
3.2 SINAMICS parameters
p0340
Automatic calculation control parameters / Calc auto par
B_INF
Can be changed: T
Calculated: -
Access level: 8
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
2
1
p0341[0...n]
Cylinder weight / Cyl weight
HLA
Can be changed: C2(1), T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 27_1
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000000 [kg]
100000.000000 [kg]
0.000000 [kg]
p0341[0...n]
Motor moment of inertia / Mot m_inert
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 5042, 5210,
6020, 6030, 6031
P-Group: Motor
Unit group: 25_1
Unit selection: p0100
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kgm²]
- [kgm²]
- [kgm²]
p0341[0...n]
Motor weight / Mot weight
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 5042, 5210
P-Group: Motor
Unit group: 27_1
Unit selection: p0100
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kg]
- [kg]
- [kg]
p0341[0...n]
Motor moment of inertia / Mot m_inert
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_ALL
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 5042, 5210,
6020, 6030, 6031
P-Group: Motor
Unit group: 25_1
Unit selection: p0100
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000000 [kgm²]
100000.000000 [kgm²]
0.000000 [kgm²]
p0342[0...n]
Ratio between the total and motor moment of inertia / Mot m_inert ratio
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 5042, 5210
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.000
10000.000
1.000
Machine data and parameters
864
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0342[0...n]
Ratio between the total and motor moment of inertia / Mot m_inert ratio
SERVO (Lin),
Can be changed: T, U
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 5042, 5210
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.000
10000.000
1.000
p0342[0...n]
Ratio between the total and motor moment of inertia / Mot m_inert ratio
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6020, 6030,
6031
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.000
10000.000
1.000
p0343[0...n]
Valve/cylinder configuration / Valve/cyl config
HLA
Can be changed: C2(1, 3)
Calculated: -
Access level: 2
Data type: Unsigned16
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p0343[0...n]
Rated motor current identified / Mot I_rated ident
VECTOR, VECTOR_AC
Can be changed: T
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
p0344[0...n]
Cylinder mounting position A side / Cyl mount pos A
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-90.0 [°]
90.0 [°]
0.0 [°]
p0344[0...n]
Motor weight (for the thermal motor model) / Mot weightThermMod
SERVO, SERVO_AC,
Can be changed: T
Calculated: CALC_MOD_ALL
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 8018
P-Group: Motor
Unit group: 27_1
Unit selection: p0100
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [kg]
50000.0 [kg]
0.0 [kg]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
865
SINAMICS parameters
3.2 SINAMICS parameters
p0345[0...n]
Required damping controlled axis / Damped ctrl axis
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.200
2.000
0.700
r0345[0...n]
Nominal motor starting time / Mot t_start_rated
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [s]
- [s]
- [s]
r0345[0...n]
Nominal motor starting time / Mot t_start_rated
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 8
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [s]
- [s]
- [s]
r0345[0...n]
Nominal motor starting time / Mot t_start_rated
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [s]
- [s]
- [s]
p0346[0...n]
Line length A side / Line length A
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [mm]
10000.0 [mm]
0.0 [mm]
p0346[0...n]
Motor excitation build-up time / Mot t_excitation
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.000 [s]
20.000 [s]
0.000 [s]
Machine data and parameters
866
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0346[0...n]
Motor excitation build-up time / Mot t_excitation
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-20.000 [s]
20.000 [s]
0.000 [s]
p0347[0...n]
Line length B side / Line length B
HLA
Can be changed: T
Calculated: CALC_MOD_REG
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [mm]
10000.0 [mm]
0.0 [mm]
p0347[0...n]
Motor de-excitation time / Mot t_de-excitat
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
20.000 [s]
0.000 [s]
p0347[0...n]
Motor de-excitation time / Mot t_de-excitat
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [s]
20.000 [s]
0.000 [s]
p0348[0...n]
Internal line diameter / Line_inner diam
HLA
Can be changed: T
Calculated: CALC_MOD_REG
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [mm]
100.0 [mm]
5.0 [mm]
p0348[0...n]
Speed at the start of field weakening Vdc = 600 V / n_strt field weak
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 5722
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [rpm]
210000.0 [rpm]
0.0 [rpm]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
867
SINAMICS parameters
3.2 SINAMICS parameters
p0348[0...n]
Velocity at the start of field weakening Vdc = 600 V / v_strt field weak
SERVO (Lin),
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
SERVO_AC (Lin)
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 5722
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [m/min]
1300.0 [m/min]
0.0 [m/min]
p0348[0...n]
Speed at the start of field weakening Vdc = 600 V / n_strt field weak
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 5722
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.0 [rpm]
210000.0 [rpm]
0.0 [rpm]
p0349
System of units motor equivalent circuit diagram data / Unit_sys mot ESB
SERVO, SERVO_AC,
Can be changed: C2(3)
Calculated: -
Access level: 1
VECTOR, VECTOR_AC
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
2
1
p0350[0...n]
Damping uncontrolled axis / Damp unctrl axis
HLA
Can be changed: T
Calculated: CALC_MOD_EQU
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.010
2.000
0.100
p0350[0...n]
Motor stator resistance cold / Mot R_stator cold
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 2
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [ohm]
2000.00000 [ohm]
0.00000 [ohm]
p0351[0...n]
Piston position natural frequency minimum / Piston pos fn min
HLA
Can be changed: T
Calculated: CALC_MOD_EQU
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.0 [mm]
3000.0 [mm]
0.0 [mm]
Machine data and parameters
868
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0351[0...n]
Motor stator resistance 20 °C / Mot R_stator 20°C
SERVO, SERVO_AC,
Can be changed: T, U
Calculated: -
Access level: 8
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [ohm]
20000.00000 [ohm]
2000.00000 [ohm]
p0352[0...n]
Axis natural frequency A side / Axis fn A
HLA
Can be changed: T
Calculated: CALC_MOD_EQU
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.0 [Hz]
2000.0 [Hz]
1.0 [Hz]
p0352[0...n]
Cable resistance / R_cable
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [ohm]
120.00000 [ohm]
0.00000 [ohm]
p0352[0...n]
Cable resistance / R_cable
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [ohm]
120.00000 [ohm]
0.00000 [ohm]
p0353[0...n]
Axis natural frequency center / Axis fn center
HLA
Can be changed: T
Calculated: CALC_MOD_EQU
Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.0 [Hz]
2000.0 [Hz]
1.0 [Hz]
p0353[0...n]
Motor series inductance / Mot L_series
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [mH]
1000000.000 [mH]
0.000 [mH]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
869
SINAMICS parameters
3.2 SINAMICS parameters
p0353[0...n]
Motor series inductance / Mot L_series
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 2
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.000 [mH]
1000000.000 [mH]
0.000 [mH]
p0354[0...n]
Axis natural frequency B side / Axis fn B
HLA
Can be changed: T
Calculated: CALC_MOD_EQU Access level: 3
Data type: FloatingPoint32
Dynamic index: DDS, p0180 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1.0 [Hz]
2000.0 [Hz]
1.0 [Hz]
p0354[0...n]
Motor rotor resistance cold / damping resistance d axis / Mot R_r cold/R_D d
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [ohm]
300.00000 [ohm]
0.00000 [ohm]
p0354[0...n]
Motor rotor resistance cold / damping resistance d axis / Mot R_r cold/R_D d
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [ohm]
300.00000 [ohm]
0.00000 [ohm]
p0355[0...n]
Motor damping resistance q axis / Mot R_damp q
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00000 [ohm]
300.00000 [ohm]
0.00000 [ohm]
p0355[0...n]
Motor damping resistance q axis / Mot R_damp q
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [ohm]
300.00000 [ohm]
0.00000 [ohm]
Machine data and parameters
870
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0356[0...n]
Motor stator leakage inductance / Mot L_stator leak
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [mH]
1000.00000 [mH]
0.00000 [mH]
p0356[0...n]
Motor stator leakage inductance / Mot L_stator leak
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [mH]
1000.00000 [mH]
0.00000 [mH]
p0357[0...n]
Motor stator inductance d axis / Mot L_stator d
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00000 [mH]
1000.00000 [mH]
0.00000 [mH]
p0357[0...n]
Motor stator inductance d axis / Mot L_stator d
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [mH]
1000.00000 [mH]
0.00000 [mH]
p0358[0...n]
Motor rotor leakage inductance / damping inductance d axis / Mot L_r leak / LDd
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [mH]
1000.00000 [mH]
0.00000 [mH]
p0358[0...n]
Motor rotor leakage inductance / damping inductance d axis / Mot L_r leak / LDd
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [mH]
1000.00000 [mH]
0.00000 [mH]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
871
SINAMICS parameters
3.2 SINAMICS parameters
p0359[0...n]
Motor damping inductance q axis / Mot L_damp q
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00000 [mH]
1000.00000 [mH]
0.00000 [mH]
p0359[0...n]
Motor damping inductance q axis / Mot L_damp q
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [mH]
1000.00000 [mH]
0.00000 [mH]
p0360[0...n]
Motor magnetizing inductance/magn. inductance d axis saturated / Mot Lh/Lh d sat
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [mH]
10000.00000 [mH]
0.00000 [mH]
p0360[0...n]
Motor magnetizing inductance/magn. inductance d axis saturated / Mot Lh/Lh d sat
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [mH]
10000.00000 [mH]
0.00000 [mH]
p0361[0...n]
Motor magnetizing inductance q axis saturated / Mot L_magn q sat
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00000 [mH]
10000.00000 [mH]
0.00000 [mH]
p0361[0...n]
Motor magnetizing inductance q axis saturated / Mot L_magn q sat
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00000 [mH]
10000.00000 [mH]
0.00000 [mH]
Machine data and parameters
872
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0362[0...n]
Motor saturation characteristic flux 1 / Mot sat flux 1
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6723, 6726
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
800.0 [%]
60.0 [%]
p0363[0...n]
Motor saturation characteristic flux 2 / Mot sat flux 2
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6723, 6726
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
800.0 [%]
85.0 [%]
p0364[0...n]
Motor saturation characteristic flux 3 / Mot sat flux 3
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6723, 6726
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
800.0 [%]
115.0 [%]
p0365[0...n]
Motor saturation characteristic flux 4 / Mot sat flux 4
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6723, 6726
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
10.0 [%]
800.0 [%]
125.0 [%]
p0366[0...n]
Motor saturation characteristic I_mag 1 / Mot sat I_mag 1
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6723, 6726
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
5.0 [%]
800.0 [%]
50.0 [%]
p0367[0...n]
Motor saturation characteristic I_mag 2 / Mot sat I_mag 2
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6723, 6726
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
5.0 [%]
800.0 [%]
75.0 [%]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
873
SINAMICS parameters
3.2 SINAMICS parameters
p0368[0...n]
Motor saturation characteristic I_mag 3 / Mot sat I_mag 3
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6723, 6726
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
5.0 [%]
800.0 [%]
150.0 [%]
p0369[0...n]
Motor saturation characteristic I_mag 4 / Mot sat I_mag 4
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6723, 6726
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
5.0 [%]
800.0 [%]
210.0 [%]
r0370[0...n]
Motor stator resistance cold / Mot R_stator cold
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 4
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
r0372[0...n]
Total power unit cable resistance / PU cable R tot
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
r0372[0...n]
Total power unit cable resistance / PU cable R tot
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
r0373[0...n]
Motor rated stator resistance / Mot R_stator rated
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 4
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: PMSM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
Machine data and parameters
874
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0374[0...n]
Motor rotor resistance cold / damping resistance d axis / Mot R_r cold/R_D d
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 4
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
r0375[0...n]
Motor damping resistance q axis / Mot R_damp q
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
r0375[0...n]
Motor damping resistance q axis / Mot R_damp q
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
r0376[0...n]
Rated motor rotor resistance / Mot rated R_rotor
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 4
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
r0377[0...n]
Motor leakage inductance total / Mot L_leak total
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6640
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r0377[0...n]
Motor leakage inductance total / Mot L_leak total
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6640
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
875
SINAMICS parameters
3.2 SINAMICS parameters
r0378[0...n]
Motor stator inductance d axis / Mot L_stator d
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r0378[0...n]
Motor stator inductance d axis / Mot L_stator d
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r0380[0...n]
Motor damping inductance d axis / Mot L_damp d
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r0380[0...n]
Motor damping inductance d axis / Mot L_damp d
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r0381[0...n]
Motor damping inductance q axis / Mot L_damp q
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r0381[0...n]
Motor damping inductance q axis / Mot L_damp q
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
Machine data and parameters
876
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0382[0...n]
Motor magnetizing inductance transformed / Lh d axis saturated / Mot L_m tr/Lhd sat
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 4
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r0383[0...n]
Motor magnetizing inductance q axis saturated / Mot L_magn q sat
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r0383[0...n]
Motor magnetizing inductance q axis saturated / Mot L_magn q sat
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: 15_1
Unit selection: p0349
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [mH]
- [mH]
- [mH]
r0384[0...n]
Motor rotor time constant / damping time constant d axis / Mot Tc_rotor/T_Dd
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 4
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6722
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
r0385[0...n]
Motor damping time constant q axis / Mot L_damping q
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
r0385[0...n]
Motor damping time constant q axis / Mot L_damping q
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
877
SINAMICS parameters
3.2 SINAMICS parameters
r0386[0...n]
Motor stator leakage time constant / Mot Tc_stator leak
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 4
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
r0387[0...n]
Motor stator leakage time constant q axis / Mot Tc_Sleak /T_Sq
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, SESM, REL
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
r0387[0...n]
Motor stator leakage time constant q axis / Mot Tc_Sleak /T_Sq
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ms]
- [ms]
- [ms]
p0388[0...n]
Motor stall torque correction factor for p1402.6 = 1 / Mot M_stallCorrNew
SERVO, SERVO_AC
Can be changed: C2(1), T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
5 [%]
300 [%]
140 [%]
p0389[0...n]
Excitation rated no-load current / Exc I_noload_rated
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [A]
10000.00 [A]
0.00 [A]
p0389[0...n]
Excitation rated no-load current / Exc I_noload_rated
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [A]
10000.00 [A]
0.00 [A]
Machine data and parameters
878
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0390[0...n]
Rated excitation current / Exc I_rated
SERVO, SERVO_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
0.00 [A]
10000.00 [A]
0.00 [A]
p0390[0...n]
Rated excitation current / Exc I_rated
VECTOR, VECTOR_AC
Can be changed: C2(1, 3)
Calculated: -
Access level: 1
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6727
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, PMSM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [A]
10000.00 [A]
0.00 [A]
p0391[0...n]
Current controller adaptation starting point Kp / I_adpt pt Kp
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 5714
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
6000.00 [Arms]
0.00 [Arms]
p0391[0...n]
Current controller adaptation starting point Kp / I_adpt pt Kp
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6714
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
6000.00 [Arms]
0.00 [Arms]
p0392[0...n]
Current controller adaptation starting point Kp adapted / I_adpt pt Kp adpt
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 5714
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
6000.00 [Arms]
0.00 [Arms]
p0392[0...n]
Current controller adaptation starting point Kp adapted / I_adpt pt Kp adpt
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: 6714
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [Arms]
6000.00 [Arms]
0.00 [Arms]
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
879
SINAMICS parameters
3.2 SINAMICS parameters
p0393[0...n]
Current controller adaptation P gain adaptation / I_adpt Kp adpt
SERVO, SERVO_AC
Can be changed: T, U
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 5714
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
1000.00 [%]
100.00 [%]
p0393[0...n]
Current controller adaptation P gain scaling / I_adpt Kp scal
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_REG
Access level: 3
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6714
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [%]
1000.00 [%]
100.00 [%]
r0394[0...n]
Rated motor power / Mot P_rated
SERVO, SERVO_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 14_6
Unit selection: p0100
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r0394[0...n]
Rated motor power / Mot P_rated
VECTOR, VECTOR_AC
Can be changed: -
Calculated: -
Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
P-Group: Motor
Unit group: 14_6
Unit selection: p0100
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [kW]
- [kW]
- [kW]
r0395[0...n]
Actual stator resistance / R_stator act
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6301, 6730,
6731, 6732
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
r0396[0...n]
Actual rotor resistance / R_rotor act
SERVO, SERVO_AC,
Can be changed: -
Calculated: -
Access level: 3
VECTOR, VECTOR_AC
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6730
P-Group: Motor
Unit group: 16_1
Unit selection: p0349
Not for motor type: PMSM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [ohm]
- [ohm]
- [ohm]
Machine data and parameters
880
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0397[0...n]
Angle magnetic decoupling maximum angle / Magn decpl max_ang
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-90.0 [°]
90.0 [°]
90.0 [°]
p0398[0...n]
Angle magn decoupling (cross saturation) coeff 1 / Magn decoupl C1
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-10.000000
10.000000
0.000000
p0398[0...n]
Angle magn decoupling (cross saturation) coeff 1 / Magn decoupl C1
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10.000000
10.000000
0.000000
p0399[0...n]
Angle magn decoupling (cross saturation) coeff 3 / Magn decoupl C3
SERVO, SERVO_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 8
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 0
Min:
Max:
Factory setting:
-10.000000
10.000000
0.000000
p0399[0...n]
Angle magn decoupling (cross saturation) coeff 3 / Magn decoupl C3
VECTOR, VECTOR_AC
Can be changed: T, U
Calculated: CALC_MOD_EQU Access level: 4
Data type: FloatingPoint32
Dynamic index: MDS, p0130 Function diagram: -
P-Group: Motor
Unit group: -
Unit selection: -
Not for motor type: ASM, SESM, REL, RESM
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-10.000000
10.000000
0.000000
p0400[0...n]
Encoder type selection / Enc_type sel
ENC, HLA, SERVO,
Can be changed: C2(1, 4)
Calculated: -
Access level: 1
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: 4700, 4704
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
10100
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
881
SINAMICS parameters
3.2 SINAMICS parameters
p0402[0...n]
Gearbox type selection / Gearbox type sel
ENC, HLA, SERVO,
Can be changed: C2(1, 4)
Calculated: -
Access level: 1
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
10100
9999
p0404[0...n]
Encoder configuration effective / Enc_config eff
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: 4010, 4704
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
p0404[0...n]
Encoder configuration effective / Enc_config eff
VECTOR, VECTOR_AC
Can be changed: C2(4)
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: 4010, 4704
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
p0405[0...n]
Square-wave encoder track A/B / Sq-wave enc A/B
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: 4704
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 1111 bin
p0407[0...n]
Linear encoder grid division / Enc grid div
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: 4010, 4704
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [nm]
250000000 [nm]
16000 [nm]
p0408[0...n]
Rotary encoder pulse number / Rot enc pulse no
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: 4010, 4704
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
16777215
2048
Machine data and parameters
882
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0408
TM41 encoder emulation pulse number / Rot enc pulse no
TM41
Can be changed: C2(4)
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 9674, 9676
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
32
16384
2048
p0410[0...n]
Encoder inversion actual value / Enc inv ActV
HLA
Can be changed: C2(4)
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: 4965
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p0410[0...n]
Encoder inversion actual value / Enc inv ActV
ENC, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: 4704, 4710,
VECTOR_AC
4711, 4715
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p0410[0...n]
Encoder inversion actual value / Enc inv ActV
ENC (Lin_enc), SERVO
Can be changed: C2(4)
Calculated: -
Access level: 3
(Lin), SERVO_AC (Lin)
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: 4704, 4710,
4711, 4715
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p0411[0...n]
Measuring gear configuration / Meas gear config
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 1
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: 4704
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p0412[0...n]
Measuring gear absolute encoder rotary revolutions virtual / Abs rot rev
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 1
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: 4704
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4194303
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
883
SINAMICS parameters
3.2 SINAMICS parameters
p0413[0...n]
Measuring gear position tracking tolerance window / Pos track window
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00
4294967300.00
0.00
p0414[0...n]
Redundant coarse position value relevant bits (identified) / Relevant bits
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
16
16
p0415[0...n]
Gx_XIST1 Coarse position safe most significant bit (identified) / Gx_XIST1 safe MSB
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
31
14
p0416[0...n]
Non safety-relevant meas. steps position value POS1 (detected) / nsrPos1
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
22000
p0417[0...n]
Encoder safety comparison algorithm (detected) / Safety comp_algo
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
255
255
p0418[0...n]
Fine resolution Gx_XIST1 (in bits) / Enc fine Gx_XIST1
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: EDS, p0140
Function diagram: 4010, 4704
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
18
11
Machine data and parameters
884
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0418
TM41 encoder emulation fine resolution Gx_XIST1 (in bits) / Enc fine Gx_XIST1
TM41
Can be changed: C2(4)
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: -
Function diagram: 9674, 9676
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
2
18
11
p0419[0...n]
Fine resolution absolute value Gx_XIST2 (in bits) / Enc fine Gx_XIST2
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: EDS, p0140
Function diagram: 4704, 4710
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
18
9
p0420[0...n]
Encoder connection / Enc_connection
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 4
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 bin
p0421[0...n]
Absolute encoder rotary multiturn resolution / Enc abs multiturn
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: 4704
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
4294967295
4096
p0422[0...n]
Absolute encoder linear measuring step resolution / Enc abs meas step
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: 4704
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [nm]
4294967295 [nm]
100 [nm]
p0423[0...n]
Absolute encoder rotary singleturn resolution / Enc abs singleturn
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: 4704
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1073741823
8192
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
885
SINAMICS parameters
3.2 SINAMICS parameters
p0424[0...n]
Encoder linear zero mark distance / Enc lin ZM_dist
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [mm]
65535 [mm]
20 [mm]
p0425[0...n]
Encoder rotary zero mark distance / Enc rot dist ZM
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: 4704, 8570
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
16777215
2048
p0426[0...n]
Encoder zero mark differential distance / Enc ZM Dif_dist
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
65535
1
p0427[0...n]
Encoder SSI baud rate / Enc SSI baud rate
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [kHz]
65535 [kHz]
100 [kHz]
p0428[0...n]
Encoder SSI monoflop time / Enc SSI t_monoflop
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [µs]
65535 [µs]
30 [µs]
p0429[0...n]
Encoder SSI configuration / Enc SSI config
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 bin
Machine data and parameters
886
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0430[0...n]
Sensor Module configuration / SM config
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1110 0000 0000 1000 0000
0000 0000 0000 bin
p0430[0...n]
Sensor Module configuration / SM config
ENC (Lin_enc), SERVO
Can be changed: C2(4)
Calculated: -
Access level: 3
(Lin), SERVO_AC (Lin)
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
1110 0000 0000 1000 0000
0000 0000 0000 bin
p0431[0...n]
Angular commutation offset / Ang_com offset
HLA, SERVO, SERVO_AC Can be changed: C2(4)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: EDS, p0140
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-180.00 [°]
180.00 [°]
0.00 [°]
p0431[0...n]
Angular commutation offset / Ang_com offset
VECTOR, VECTOR_AC
Can be changed: C2(4)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: EDS, p0140
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: ASM, REL
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-180.00 [°]
180.00 [°]
0.00 [°]
p0432[0...n]
Gearbox factor encoder revolutions / Grbx_fact enc_rev
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Integer32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
1048576
1
p0433[0...n]
Gearbox factor motor/load revolutions / Grbx_fact mot/load
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Integer32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
1
1048576
1
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
887
SINAMICS parameters
3.2 SINAMICS parameters
p0434[0...n]
Encoder SSI error bit / Enc SSI error bit
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p0435[0...n]
Encoder SSI alarm bit / Enc SSI alarm bit
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p0436[0...n]
Encoder SSI parity bit / Enc SSI parity bit
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p0437[0...n]
Sensor Module configuration extended / SM config ext
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0011 0000 0000 0000 0000
1000 0000 0000 bin
p0437[0...n]
Sensor Module configuration extended / SM config ext
ENC (Lin_enc), SERVO
Can be changed: C2(4)
Calculated: -
Access level: 3
(Lin), SERVO_AC (Lin)
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0011 0000 0000 0000 0000
1000 0000 0000 bin
p0438[0...n]
Square-wave encoder filter time / Enc t_filt
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.00 [µs]
100.00 [µs]
0.64 [µs]
Machine data and parameters
888
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
p0439[0...n]
Encoder ramp-up time / Enc ramp-up time
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0 [ms]
65535 [ms]
0 [ms]
p0440[0...n]
Copy encoder serial number / Copy enc ser_no
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
1
0
p0441[0...n]
Encoder commissioning serial number part 1 / Enc com ser_no 1
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: CALC_MOD_ALL
Access level: 4
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p0442[0...n]
Encoder commissioning serial number part 2 / Enc com ser_no 2
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: CALC_MOD_ALL
Access level: 4
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p0443[0...n]
Encoder commissioning serial number part 3 / Enc com ser_no 3
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: CALC_MOD_ALL
Access level: 4
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p0444[0...n]
Encoder commissioning serial number part 4 / Enc com ser_no 4
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: CALC_MOD_ALL
Access level: 4
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
889
SINAMICS parameters
3.2 SINAMICS parameters
p0445[0...n]
Encoder commissioning serial number part 5 / Enc com ser_no 5
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: CALC_MOD_ALL
Access level: 4
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0000 hex
FFFF FFFF hex
0000 hex
p0446[0...n]
Encoder SSI number of bits before the absolute value / Enc SSI bit before
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p0447[0...n]
Encoder SSI number of bits absolute value / Enc SSI bit val
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
25
p0448[0...n]
Encoder SSI number of bits after the absolute value / Enc SSI bit after
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
0
p0449[0...n]
Encoder SSI number of bits filler bits / Enc SSI fill bits
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0
65535
1
r0451[0...2]
Commutation angle factor / Enc commut_factor
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: -
Function diagram: 4710
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
890
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0452[0...2]
Square-wave encoder filter time display / Enc t_filt disp
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [µs]
- [µs]
- [µs]
r0452
Square-wave encoder filter time display / Enc t_filt disp
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [µs]
- [µs]
- [µs]
p0453[0...n]
Pulse encoder evaluation zero speed measuring time / Enc_ev n_0 t_meas
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: FloatingPoint32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
0.10 [ms]
10000.00 [ms]
1000.00 [ms]
p0454[0...n]
Sensor Module configuration extended Part 2 / SM config ext 2
ENC, HLA, SERVO,
Can be changed: C2(4)
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: EDS, p0140
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0000 0000 bin
r0455[0...2]
Encoder configuration recognized / Enc_config recog
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0455
Encoder configuration recognized / Enc_config recog
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
891
SINAMICS parameters
3.2 SINAMICS parameters
r0456[0...2]
Encoder configuration supported / Enc_config sup
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0456
Encoder configuration supported / Enc_config sup
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0457[0...2]
Sensor Module properties extended Part 2 / SM prop ext 2
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0457
Sensor Module properties extended Part 2 / SM prop ext 2
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0458[0...2]
Sensor Module properties / SM properties
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: 4704
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0458[0...2]
Sensor Module properties / SM properties
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32
Dynamic index: -
Function diagram: 4704
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
892
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0458
Sensor Module properties / SM properties
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 4704
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0458
Sensor Module properties / SM properties
ENC (Lin_enc)
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: 4704
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0459[0...2]
Sensor Module properties extended / SM prop ext
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0459[0...2]
Sensor Module properties extended / SM prop ext
SERVO (Lin),
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC (Lin)
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0459
Sensor Module properties extended / SM prop ext
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0459
Sensor Module properties extended / SM prop ext
ENC (Lin_enc)
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
893
SINAMICS parameters
3.2 SINAMICS parameters
r0460[0...2]
Encoder serial number part 1 / Enc ser_no 1
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0460
Encoder serial number part 1 / Enc ser_no 1
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0461[0...2]
Encoder serial number part 2 / Enc ser_no 2
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0461
Encoder serial number part 2 / Enc ser_no 2
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0462[0...2]
Encoder serial number part 3 / Enc ser_no 3
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0462
Encoder serial number part 3 / Enc ser_no 3
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
894
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0463[0...2]
Encoder serial number part 4 / Enc ser_no 4
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0463
Encoder serial number part 4 / Enc ser_no 4
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0464[0...2]
Encoder serial number part 5 / Enc ser_no 5
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0464
Encoder serial number part 5 / Enc ser_no 5
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0465[0...27]
Encoder 1 identification number/serial number / Enc1 ID_no/ser_no
ENC, HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0466[0...27]
Encoder 2 identification number/serial number / Enc2 ID_no/ser_no
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
895
SINAMICS parameters
3.2 SINAMICS parameters
r0467[0...27]
Encoder 3 identification number/serial number / Enc3 ID_no/ser_no
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned8
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0469[0...2]
Absolute encoder linear measuring step / Enc lin meas step
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [nm]
- [nm]
- [nm]
r0469
Absolute encoder linear measuring step / Enc lin meas step
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
- [nm]
- [nm]
- [nm]
r0470[0...2]
Redundant coarse position value valid bits / Valid bits
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0470
Redundant coarse position value valid bits / Valid bits
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0471[0...2]
Redundant coarse position value fine resolution bits / Fine bit
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Integer16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
896
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0471
Redundant coarse position value fine resolution bits / Fine bit
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0472[0...2]
Redundant coarse position value relevant bits / Relevant bits
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0472
Redundant coarse position value relevant bits / Relevant bits
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0473[0...2]
Non safety-relevant measuring steps position value pos1 / nsrPos1
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0473
Non safety-relevant measuring steps position value pos1 / nsrPos1
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0474[0...2]
Redundant coarse position value configuration / Red pos config
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4
897
SINAMICS parameters
3.2 SINAMICS parameters
r0474
Redundant coarse position value configuration / Red pos config
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0475[0...2]
Gx_XIST1 coarse position safety most significant bit / Gx_XIST1 safe MSB
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned16
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0475
Gx_XIST1 coarse position safety most significant bit / Gx_XIST1 safe MSB
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0476[0...n]
Piston zero point calibration value / Piston 0 pt cal
HLA
Can be changed: T
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: EDS, p0140
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-2147483648
2147483647
0
r0477[0...2]
CO: Measuring gear position difference / Meas gear pos diff
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 1
SERVO_AC, VECTOR,
Data type: Integer32
Dynamic index: -
Function diagram: -
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0477
CO: Measuring gear position difference / Meas gear pos diff
ENC
Can be changed: -
Calculated: -
Access level: 1
Data type: Integer32
Dynamic index: -
Function diagram: -
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
Machine data and parameters
898
List Manual, 10/2020, 6FC5397-7AP40-6BA4
SINAMICS parameters
3.2 SINAMICS parameters
r0479[0...2]
CO: Diagnostics encoder position actual value Gn_XIST1 / Diag Gn_XIST1
HLA, SERVO,
Can be changed: -
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Integer32
Dynamic index: -
Function diagram: 4704
VECTOR_AC
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0479
CO: TM41 encoder emulation diagnostics Gn_XIST1 / Diag Gn_XIST1
TM41
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: -
Function diagram: 9674, 9676
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
r0479
CO: Diagnostics encoder position actual value Gn_XIST1 / Diag Gn_XIST1
ENC
Can be changed: -
Calculated: -
Access level: 3
Data type: Integer32
Dynamic index: -
Function diagram: 4704
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
-
p0480[0...2]
CI: Encoder control word Gn_STW signal source / Enc Gn_STW s_s
HLA, SERVO,
Can be changed: T
Calculated: -
Access level: 3
SERVO_AC, VECTOR,
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 4700, 4720,
VECTOR_AC
4750
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
p0480
CI: Encoder control word Gn_STW signal source / Enc Gn_STW s_s
ENC
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / Integer16
Dynamic index: -
Function diagram: 4700, 4720,
4750
P-Group: Encoder
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
Max:
Factory setting:
-
-
0
Machine data and parameters
List Manual, 10/2020, 6FC5397-7AP40-6BA4