SINUMERIK 840D sl Hardware. Manual (2011-2020) - page 9

 

  Index      Manuals     SINUMERIK 840D sl Hardware. Manual (2011-2020)

 

Search            copyright infringement  

 

   

 

   

 

Content      ..     7      8      9      10     ..

 

 

 

SINUMERIK 840D sl Hardware. Manual (2011-2020) - page 9

 

 

Table of contents
9.6
PROFIBUS communication
307
9.6.1
Prerequisites
307
9.6.2
Configuring the DP slave MPP 483
308
9.6.3
PLC user program
311
9.7
Maintenance and Service
311
9.8
Diagnostics
312
9.8.1
LED displays
312
9.8.2
Output functions
313
9.8.3
Key test
314
9.9
Technical data
315
9.9.1
MPP 483
315
9.9.2
Input/output interface of individual wiring
316
9.10
Accessories and spare parts
319
9.10.1
Overview
319
9.10.2
Labeling the slide-in labels
319
9.10.3
Handwheel connection
324
9.10.4
Display elements and operator controls
324
10
MCP Interface PN
327
10.1
Description
327
10.2
Interfaces
330
10.2.1
Overview
330
10.2.2
Terminals
331
10.2.3
Switch
342
10.2.4
Input / output images
345
10.3
Mounting
348
10.4
Technical data
349
11
Electronic handwheels
351
11.1
Description
351
11.2
Dimension drawings
353
11.2.1
Encoder with 120 mm x 120 mm front panel, setting wheel (...-5DB01)
353
11.2.2
Encoder with front panel, 76.2 mm x 76.2 mm, setting wheel (...-5DC01)
354
11.2.3
Encoder without front panel, without setting wheel (...-5DF01)
355
11.2.4
Encoder with front panel, 76.2 mm x 76.2 mm, setting wheel (...-5DH01)
356
11.2.5
Encoder without front panel, with setting wheel (...-5DM00)
357
11.3
Connections
358
11.4
Technical data
358
11.5
Accessories
359
12
Rotary override switch
361
12.1
Description
361
12.2
Mounting
362
12.2.1
Dimension drawings
362
12.2.2
Replacing the rotary switch
364
Machine control panels
8
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310C PN
1
1.1
Description
Machine control panel MCP 310C PN (PN = PROFINET) enables user-friendly operation of
the machine functions. It is suitable for machine-level operation of milling, turning, grinding
and special machines)
Note
The IE functionality (IE = Industrial Ethernet) is still included and preset.
Please note the switch position of S2.
All keys are designed with replaceable covers for machine-specific adaptations. The key
covers can be freely inscribed using a laser. Clear key covers can be used as an alternative.
The machine control panel is secured from the rear with special clamps supplied with the panel.
Validity
This description applies to the machine control panel:
Type
Key type
Article number
MCP 310C PN
Mechanical short-stroke keys
6FC5303-0AF23-0AA1
The safety-related accessories / spare parts are marked in the "Accessories and spare parts"
section with a *).
Features
Control elements:
● Mechanical short-stroke keys
● Operating mode and function keys:
-
49 keys with assigned LEDs
– Direction keys for milling machines with rapid traverse override
(Key covers are supplied for direction keys for turning machines.)
For information, refer to Section: "Control and display elements" → "Front").
● Feed control with override feed / rapid traverse (rotary switch with 23 positions)
● Key-operated switch (four positions and three different keys)
Interfaces:
● Ethernet (transfer rate: 10/100 Mbit/s; for IE and PN)
● Nine customer-specific inputs (e.g. for illuminated pushbuttons)
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
11
Machine control panel: MCP 310C PN
1.1 Description
● Six customer-specific outputs
● Connection for two handwheels (Sub-D)
Expansion slots:
Six slots for control devices (d = 16 mm)
(Additional cable set required for control devices, see Section: "Accessories and spare parts".)
Machine control panels
12
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310C PN
1.2 Operator control and display elements
1.2
Operator control and display elements
1.2.1
Front
(1)
Operating modes and machine functions
(2)
16 customer keys
(3)
Spindle control
(4)
Slot for EMERGENCY STOP button or spindle override switch
(5)
Feed control with override switch
(6)
Slots for control devices 16 mm *)
(7)
Program control
(8)
Key-operated switch
*) See slots for control devices
Image 1-1
Arrangement of the MCP 310C PN control elements
EMERGENCY STOP button
If an EMERGENCY STOP button is added: See Chapter "Machine control panel MCP 483
PN", Section "Control and display elements" → "Front".
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
13
Machine control panel: MCP 310C PN
1.2 Operator control and display elements
Slots for control devices
NOTICE
Damage to the front
Do not break the openings for the installation of operating devices (6), but rather drill them to
the required size.
Key covers
All keys of the MCP 310C PN come with changeable key covers.
Refer to the following table for the additional replacement key covers provided for turning
machines in the accessories pack.
Key cover
Symbol number
Key cover
Symbol number
7027
7129
7125
7130
7126
7131
7127
7132
7128
The article numbers for the key covers can be found in Section "Accessories and spare parts".
Machine control panels
14
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310C PN
1.2 Operator control and display elements
1.2.2
Rear side
(1)
Slot for Emergency Stop button or spindle override
(2)
Power supply interface
X10
(3)
Handwheel connection
X60
(4)
Handwheel connection
X61
(5)
switch S1 *)
(6)
Switch S2 *)
(7)
LEDs *)
(8)
Ethernet cable strain relief
(9)
Ethernet connection, port 2
X21
(10)
Ethernet connection, port 1
X20
(11)
Equipotential bonding
(12)
Feed override
(13)
Customer-specific inputs and outputs *)
*) Detailed description under: "Interfaces" → "Overview"
Image 1-2
Rear of the MCP 310C PN with Ethernet connecting cables
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
15
Machine control panel: MCP 310C PN
1.3 Interfaces
1.3
Interfaces
1.3.1
Overview
;
;
;
6
;
;
;
;
;
;
;
;
;
6
+
+
+
Image 1-3
Rear of the MCP 310C PN with interfaces
X10
Power supply interface
X20
Ethernet port 1
X21
Ethernet port 2
X30
Interface for rotary switch feed override
X31
Interface for rotary switch spindle override / Emergency Stop (optional)
X51 / X52 / X55
Interfaces for customer-specific inputs
X53 / X54
Interfaces for customer-specific outputs
X60 / X61
Connections for 2 handwheels (TTL / differential - can be set with switch S1)
S1
Switch for setting the handwheel signal type
S2
Switch for setting the MCP address
(1)
Equipotential bonding
Machine control panels
16
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310C PN
1.3 Interfaces
LEDs
H1
POWER OK (green)
H2
BUSSYNC
H3
BUSFAULT
Equipotential bonding
The equipotential bonding conductor is attached by means of an M5 screw.
1.3.2
Description
Pin assignment
For more detailed information, see "General information and networking", Chapter:
"Connecting".
Switch S1
The handwheel signal type is set with switch S1.
● S1 open: TTL
● S1 closed: Differential interface
Switch S1 is closed when supplied ex works.
Switch S2
MCP set up as PN
Table 1-1
Basic setting of the switch S2
1-8
9
10
Meaning
See Table "Settings of switch S2"
on
on
PN
off
off
IE (default)
The two switches S2-9 and S2-10 must be set to "on" in order for PN functionality to be
supported.
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
17
Machine control panel: MCP 310C PN
1.3 Interfaces
The switches S2-1 to S2-8 define the default device name.
Up to 128 default device names are supported. If these default device names are used, there
is no need for initialization of the MCP.
Note
The default device names cannot be reconfigured using the STEP7 "Device initialization"
function for example.
If you are connecting the MCP to a SINUMERIK control as a PROFINET component, make
sure that this functionality is supported by the control concerned.
DCP mode:
No default device name is available in this mode. The device name must be set by means of
an initialization procedure and remains saved on the MCP. It is deleted again if the factory
setting is restored, e.g. using STEP7.
Table 1-2
Settings of switch S2
1
2
3
4
5
6
7
8
9
10
Meaning
on
on
on
on
on
on
on
on
on
on
DCP mode
on
on
on
on
on
on
on
off
Default device name: mcp-pn127
off
on
on
on
on
on
on
off
Default device name: mcp-pn126
on
off
on
on
on
on
on
off
Default device name: mcp-pn125
off
off
on
on
on
on
on
off
Default device name: mcp-pn124
on
on
off
on
on
on
on
off
Default device name: mcp-pn123
off
on
off
on
on
on
on
off
Default device name: mcp-pn122
on
off
off
on
on
on
on
off
Default device name: mcp-pn121
off
off
off
on
on
on
on
off
Default device name: mcp-pn120
on
on
on
off
on
on
on
off
Default device name: mcp-pn119
off
on
on
off
on
on
on
off
Default device name: mcp-pn118
on
off
on
off
on
on
on
off
Default device name: mcp-pn117
off
off
on
off
on
on
on
off
Default device name: mcp-pn116
on
on
off
off
on
on
on
off
Default device name: mcp-pn115
off
on
off
off
on
on
on
off
Default device name: mcp-pn114
on
off
off
off
on
on
on
off
Default device name: mcp-pn113
off
off
off
off
on
on
on
off
Default device name: mcp-pn112
x
x
x
x
x
x
x
x
"
on
on
on
on
off
off
off
off
Default device name: mcp-pn15
off
on
on
on
off
off
off
off
Default device name: mcp-pn14
on
off
on
on
off
off
off
off
Default device name: mcp-pn13
off
off
on
on
off
off
off
off
Default device name: mcp-pn12
on
on
off
on
off
off
off
off
Default device name: mcp-pn11
Machine control panels
18
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310C PN
1.3 Interfaces
1
2
3
4
5
6
7
8
9
10
Meaning
off
on
off
on
off
off
off
off
Default device name: mcp-pn10
on
off
off
on
off
off
off
off
Default device name: mcp-pn9
off
off
off
on
off
off
off
off
Default device name: mcp-pn8
on
on
on
off
off
off
off
off
Default device name: mcp-pn7
off
on
on
off
off
off
off
off
Default device name: mcp-pn6
on
off
on
off
off
off
off
off
Default device name: mcp-pn5
off
off
on
off
off
off
off
off
Default device name: mcp-pn4
on
on
off
off
off
off
off
off
Default device name: mcp-pn3
off
on
off
off
off
off
off
off
Default device name: mcp-pn2
on
off
off
off
off
off
off
off
Default device name: mcp-pn1
off
off
off
off
off
off
off
off
Default device name: mcp-pn
MCP set up as IE
A logical address can be assigned to the MCP for communication via Ethernet using the 10-
bit switch S2.
Table 1-3
Switch S2 is set as delivered
1
2
3
4
5
6
7
8
9
10
Meaning
off
off
off
off
off
off
on
on
off
off
MCP address 192
The two switches S2-9 and S2-10 must remain set to "off" (IE functionality).
The switches S2-1 to S2-8 define the MCP address in the range of 0 to 255.
The addresses from 192 to 223 count as the default range.
The MCP address is used as a reference for addressing an MCP during PLC parameter
assignment.
Table 1-4
Settings of switch S2
1
2
3
4
5
6
7
8
9
10
Meaning
off
off
on
on
on
on
on
on
on
on
MCP address 255
x
x
x
x
x
x
x
x
"
on
on
on
on
on
off
on
on
MCP address 223
off
on
on
on
on
off
on
on
MCP address 222
on
off
on
on
on
off
on
on
MCP address 221
off
off
on
on
on
off
on
on
MCP address 220
on
on
off
on
on
off
on
on
MCP address 219
off
on
off
on
on
off
on
on
MCP address 218
on
off
off
on
on
off
on
on
MCP address 217
off
off
off
on
on
off
on
on
MCP address 216
on
on
on
off
on
off
on
on
MCP address 215
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
19
Machine control panel: MCP 310C PN
1.3 Interfaces
1
2
3
4
5
6
7
8
9
10
Meaning
off
on
on
off
on
off
on
on
MCP address 214
on
off
on
off
on
off
on
on
MCP address 213
off
off
on
off
on
off
on
on
MCP address 212
on
on
off
off
on
off
on
on
MCP address 211
off
on
off
off
on
off
on
on
MCP address 210
on
off
off
off
on
off
on
on
MCP address 209
off
off
off
off
on
off
on
on
MCP address 208
on
on
on
on
off
off
on
on
MCP address 207
off
on
on
on
off
off
on
on
MCP address 206
on
off
on
on
off
off
on
on
MCP address 205
off
off
on
on
off
off
on
on
MCP address 204
on
on
off
on
off
off
on
on
MCP address 203
off
on
off
on
off
off
on
on
MCP address 202
on
off
off
on
off
off
on
on
MCP address 201
off
off
off
on
off
off
on
on
MCP address 200
on
on
on
off
off
off
on
on
MCP address 199
off
on
on
off
off
off
on
on
MCP address 198
on
off
on
off
off
off
on
on
MCP address 197
off
off
on
off
off
off
on
on
MCP address 196
on
on
off
off
off
off
on
on
MCP address 195
off
on
off
off
off
off
on
on
MCP address 194
on
off
off
off
off
off
on
on
MCP address 193
off
off
off
off
off
off
on
on
MCP address 192
x
x
x
x
x
x
x
x
"
on
off
off
off
off
off
off
off
MCP address 001
off
off
off
off
off
off
off
off
MCP address 000
You can find the settings for the basic PLC program in:
Function Manual, Basic Functions (P3 sl)
Machine control panels
20
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310C PN
1.3 Interfaces
1.3.3
Input / output images
Standard + two handwheels
The specifications for assigning input and output bytes listed in the tables can be changed in
the PLC via parameter assignment.
Note
The following applies in respect of the process input and output images in the tables: n is
defined by means of FB1 parameters in OB100 of the PLC.
Table 1-5
Process input image for MCP 310C PN
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
EB n + 0
* NC
Spindle
Spindle
Spindle +
Single
JOG
MDA
AUTO
Stop
100%
block
EB n + 1
NC
Spindle
* Spindle
Spindle
Key-operat-
REF
REPOS
Teach
start
right
stop
left
ed
IN
switch
position 3
EB n + 2
Feed
* Feed
INC VAR
Key-operat-
INC 1000
INC 100
INC 10
INC 1
start
stop
ed
switch
position 0
EB n + 3
Key-operated switch
Feed override
RESET
Position 2
Position 1
E (24)
D (23)
C (22)
B (21)
A (20)
EB n + 4
Arrow keys
KT-IN5
KT-IN4
KT-IN3
KT-IN2
KT-IN1
+
-
Rapid tra-
X52.2
X52.1
X51.3
X51.2
X51.1
verse
EB n + 5
T16
KT-IN6
Axis selection
X52.3
6
5
4
Z
Y
X
EB n + 6
Unassigned customer keys
Unassigned customer keys
T9
T10
T11
T12
Work
T13
T14
T15
Machine
EB n + 7
Unassigned customer keys
T1
T2
T3
T4
T5
T6
T7
T8
EB n + 8
-
-
-
-
-
-
-
-
EB n + 9
-
-
-
-
-
-
-
-
EB n + 10
KT-IN8
KT-IN7
KT-IN6
KT-IN5
KT-IN4
KT-IN3
KT-IN2
KT-IN1
X55.2
X55.1
X52.3
X52.2
X52.1
X51.3
X51.2
X51.1
EB n + 11
-
-
-
-
-
-
-
KT-IN9
X55.3
EB n + 12
-
-
-
-
-
-
-
-
EB n + 13
-
-
-
X31
X31
X31
X31
X31
pin 6 1)
pin 7 1)
pin 8 1)
pin 9 1)
pin 10 1)
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
21
Machine control panel: MCP 310C PN
1.3 Interfaces
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Signals marked with * are inverse signals.
1)
If the 4-stage rotary spindle override switch on X31 is replaced by a 5-stage rotary switch, the input information here
can be measured in five stages.
Table 1-6
Output image MCP 310C PN
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
AB n + 0
* NC
Spindle
Spindle
Spindle +
Single
JOG
MDA
AUTO
stop
100%
block
AB n + 1
NC
Spindle
* Spindle
Spindle
RESET
REF
REPOS
Teach
start
right
stop
left
IN
AB n + 2
Feed
* Feed
INC VAR
-
INC 1000
INC 100
INC 10
INC 1
start
stop
AB n + 3
-
-
-
-
-
-
-
-
AB n + 4
+
_
Rapid tra-
KT-OUT5
KT-OUT4
KT-OUT3
KT-OUT2
KT-OUT1
verse
X54.2
X54.1
X53.3
X53.2
X53.1
AB n + 5
T16
KT-OUT6
6
5
4
Z
Y
X
X54.3
AB n + 6
Unassigned customer keys
T9
T10
T11
T12
Work
T13
T14
T15
Machine
AB n + 7
Unassigned customer keys
T1
T2
T3
T4
T5
T6
T7
T8
Signals marked with * are inverse signals
Default key assignment
-2*
Spindle
100
Spindle
REP
REF
VAR
7
7
7
Dec.
%
Inc.
MDA
Teach
7
1
7
7
7
Spindle
Spindle
Spindle
IN
Right
Stop
Left
Auto
7
7
10
7
7
7
X
Y
Z
Single
4th
5th
6th
Reset
7
100
7
7
7
Bliock
Axis
Axis
Axis
Cycle
Cycle
WCS
Feed
Feed
1000
-
Rapid
+
Stop
Start
MCS
Stop
Start
,QSXWV LQYHUWHG
7
7
XQODEHOHG NH\V
Image 1-4
Default key assignment of MCP 310C PN
Machine control panels
22
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310C PN
1.4 Mounting
Assignment of the inputs (I) and outputs (O) to the keys and LEDs
,
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
2
,
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
2
,
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
2
,
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
2
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
,QSXWV LQYHUWHG
Image 1-5
Inputs and outputs of the MCP 310C PN keyboard
1.4
Mounting
Dimension drawing
Image 1-6
MCP 310C PN dimension drawing
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
23
Machine control panel: MCP 310C PN
1.5 Connecting
Tension jacks
The machine control panel is attached using 6 tension jacks (tightening torque, 0.5 Nm).
0RXQWLQJ SDQHO
6HDOLQJ DUHD
3UHVVXUH SRLQWV
IRU WHQVLRQ MDFNV
,Q WKH VHDOLQJ DUHD
Image 1-7
Panel cut-out for machine control panel MCP 310C PN
Mounting position
Max. 60° to the vertical.
For mounting positions greater than 60°, a fan must also be installed to keep the ambient
temperature of the machine control panel constantly below 55 °C.
1.5
Connecting
Two equivalent connections (Fast Ethernet) are available for Ethernet/PROFINET transfer.
The Ethernet cables are not included in the scope of delivery. They must be ordered separately.
The following components are recommended:
● Ethernet FastConnect cables
● Ethernet FastConnect connectors
More information on this can be found in the SIEMENS IK PI catalog.
Machine control panels
24
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310C PN
1.6 Maintenance and Service
Securing Ethernet cables
Two cable ties are included in the scope of delivery. These are used to secure the Ethernet
cables on the cover plate at the rear of the machine control panel (see figure in Section: "Control
and display elements" → "Rear side").
NOTICE
Damaged cables caused by chafing edges
Make sure that all cables are routed so that they do not come into contact with chafing edges.
1.6
Maintenance and Service
Cleaning the device
Use a soft cloth moistened either with water or a mild cleaning agent to clean the housing and
operator control elements of the machine control panel.
Checking the device
In order to prevent foreign bodies or liquids entering the machine control panel, regularly check
the device
● that all the housing screws are in place and tight
● for damage to the housing
● for damage to the cable cover or cable entry
Protect the device from environmental effects
Protect the machine control panel against
● direct solar radiation and heat sources
● mechanical vibration and shock
● dust
● moisture, and
● strong magnetic fields
Check of the emergency stop button (if the emergency stop button has been retrofitted)
Check the emergency stop button regularly to ensure that it functions correctly.
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
25
Machine control panel: MCP 310C PN
1.7 Technical data
1.7
Technical data
MCP 310C PN machine control panel
Safety
Safety class
III; PELV according to EN 50178
Degree of protection ac-
Front side: IP54
Rear side: IP00
cording to EN 60529
Approvals
CE / cULus
Electrical data
Input voltage
24 VDC
Power consumption, max.
Board:
Lamps:
Handwheels:
Total:
5 W
14.4 W
2 x 0.9 W
21.2 W
(6 x 2.4 W) *)
Mechanical data
Dimensions
Width: 310 mm
Height: 175 mm
Depth: 85.2 mm
Mounting depth: 29.1 mm
Weight
Approx. 1.2 kg
*)
The outputs for the illuminated pushbuttons (X53/X54) can have a max. permissible current of 0.3 A.
However, the total current consumption of the components must not exceed 1.0 A (24 W).
Note
Information about the climatic and mechanical environmental conditions is contained in the
associated section under:
"General notes and interconnection" → "Operational planning".
Emergency stop button
Rated voltage
24 VDC
Current magnitude, max.
3 A
Current magnitude, min.
1 mA
Switching capacity
DC 13 according to EN 60947-5-1
Conditional rated short-circuit current
10 A gL/gG according to EN 60947-5-1
B10d
500 000
Note
The quantitative assessment of the emergency stop safety function must be based on the
B10d values corresponding to the used standards (e.g. ISO 13849-1) under consideration of
the respective application (frequency of the actuation, service life, diagnostics by the evaluation
unit, etc.). The B10d values only apply when the technical properties of the emergency stop
button are taken into account.
Machine control panels
26
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310C PN
1.8 Accessories and spare parts
1.8
Accessories and spare parts
Table 1-7
Accessories and spare parts for machine control panel 310C PN
Name
Description
Quanti-
Article number
ty
Emergency Stop button
22 mm actuating element, 40mm mushroom pushbutton,
1
3SB3000-1HA20 *)
snap action with tamper protection, latching, red, with hold-
er, unlit
Contact block
With two contact pairs (1 NO + 1 NC), 2-pin, screw terminal
1
3SB3400-0A *)
(3rd contact pair can be connected additionally)
Key
Ten key sets, each with three keys for the keyswitch settings
1 set
6FC5148-0AA03-0AA0
1, 2, 3
Tension jacks
Tension jack set (9 items) for supplementary components
1 set
6FC5248-0AF14-0AA0
with 2.5 mm profile, length 20 mm
Override, spindle
Override spindle / rapid traverse, electronic rotary switch
1
6FC5247-0AF12-1AA0
rotary switch
1x16G, T=24, cap, button, pointer, spindle dials and rapid
traverse
Override, feed
Feed / rapid traverse override, electronic rotary switch
1
6FC5247-0AF13-1AA0
rotary switch
1x23G, T=32, cap, button, pointer, feed and rapid-traverse
dials
Key cover
Square, can be labeled by laser, 1 set of 90, ergo-gray and
1
6FC5248-0AF12-0AA0
20 each of red / green / yellow / medium gray
Key cover
Square, for inscription plates, 1 set of 90, clear
1
6FC5248-0AF21-0AA0
Key cover
Square, can be written with laser, one set with 500 items,
1
6FC5348-0AF00-0AA0
ergo-gray (light basic)
Key cover
Square, can be written with laser, one set with 500 items,
1
6FC5348-0AF01-0AA0
mid-gray (light basic)
Cable set
60 cables for additional MCP control devices, 500 mm long
1 set
6FC5247-0AA35-0AA0
Signal cable, handwheel
Connecting cable for the handwheel, max. length: 5 m
1
6FX8002-2CP00-1Axy
xy is the length code:
x (m) = A (0) ...F (5); y (dm) = 0 ... 8
*) Safety-related
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
27
Machine control panel: MCP 310C PN
1.8 Accessories and spare parts
/HQJWK FRUUHVSRQGLQJ WR WKH OHQJWK FRGH s
3LQ
s
6KLHOG
3
*1
*1
0
*(
<(
$B+:
25
2*
;$B+:
57
5'
%B+:
%/
%8
;%B+:
9,
97
3
%5
%1
0
6:
%.
6KLHOG
① Rating plate of the cable with article no., length in m, manufacturer, month/year of manufacture
② Pin cable lug
③ Ring cable lug
④ Flexible cable 0.75 mm2
Image 1-8
Connection cable for COM board handwheel
Table 1-8
Accessories pack (for delivery ex works)
9
Key covers for turning (labeled)
1
Keyset
30
Ergo gray key covers (for labeling)
30
Clear key covers (for labeling)
1
Yellow backing plate for emergency stop
Machine control panels
28
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310 PN
2
2.1
Description
Machine control panel MCP 310 PN (PN = PROFINET) enables user-friendly operation of the
machine functions, which are clearly laid out for the user. It is suitable for machine-level
operation of milling, turning, grinding and special machines.
Note
The IE functionality (IE = Industrial Ethernet) is still included and preset.
Please note the switch position of S2.
49 keys have user-inscribed slide-in labels for machine-specific adaptations. A DIN A4 film for
labeling the slide-in strips is included in the scope of delivery.
A connecting cable is included in the scope of delivery for connecting the direct keys of the
SINUMERIK operator panel fronts OP 012 / OP 015A and TP 015A.
The machine control panel is secured from the rear using special clamps supplied with the
panel.
Validity
This description applies to the machine control panel:
Type
Key type
Article number
MCP 310 PN
Membrane keys
6FC5303-0AF23-1AA1
The safety-related accessories / spare parts are marked in the "Accessories and spare parts"
section with a *).
Features
Control elements:
● Membrane keys
● Operating mode and function keys:
-
49 keys with assigned LEDs, 16 freely assignable customer keys in the standard
assignment
- Direction keys for milling machines with rapid traverse override
● Feed control with override feed / rapid traverse (rotary switch with 23 positions)
● Key-operated switch (four positions and three different keys)
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
29
Machine control panel: MCP 310 PN
2.1 Description
Interfaces:
● Ethernet (transfer rate: 10/100 Mbit/s; for IE and PN)
● Nine customer-specific inputs (e.g. for illuminated pushbuttons)
● Six customer-specific outputs
● For 16 direct keys of OP 012 / OP 015A / TP 015A (connection cable: 850 mm, included
in scope of delivery)
● Connection for 2 handwheels (Sub-D)
(velocity input and contour handwheel are only possible if connecting through the
handwheel connection module or the MCP PN interface)
Expansion slots:
● Six slots for control devices (d = 16 mm)
(Additional cable set required for control devices, see Section: "Accessories and spare
parts".)
● One slot for emergency stop key or rotary override switch (up to d = 22 cm)
Machine control panels
30
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310 PN
2.2 Operator controls and indicators
2.2
Operator controls and indicators
2.2.1
Front side
Overview
(1)
Operating modes and machine functions
(2)
16 customer keys
(3)
Spindle control
(4)
Slot for emergency stop button or spindle override switch
(5)
Feed control with override switch
(6)
Slots for control devices 16 mm *)
(7)
Program control
(8)
Key-operated switch
*) see slots for control devices
Image 2-1
Position of control elements on machine control panel MCP 310 PN
Emergency stop button
If an emergency stop button is added: see Chapter: "Machine control panel: MCP 483 PN",
Section: "Display and operating elements" → "Front".
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
31
Machine control panel: MCP 310 PN
2.2 Operator controls and indicators
Slots for control devices
NOTICE
Damage to the front
Do not break the openings for the installation of operating devices (6), but rather drill them to
the required size.
With the selection of the control devices, please take care of the surface characteristics of the
MCP:
For technical reasons, the film ② is approximately 0.1 to 0.5 mm lower than the contact surface
of the control device ①. Due to this difference, assess the height of the plastic ring.
Image 2-2
Installation of the control devices 16 mm
Machine control panels
32
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310 PN
2.2 Operator controls and indicators
2.2.2
Rear side
Rear
① Feedrate override
X30
② Slot for emergency stop button or spindle override
③ Power supply interface
X10
④ Customer-specific inputs and outputs *)
⑤ Switch S1 *)
⑥ Handwheel connection
X60
⑦ Handwheel connection
X61
⑧ Ethernet connection, port 1
X20
⑨ Ethernet connection, port 2
X21
⑩ Ethernet cable strain relief
⑪ LEDs *)
⑫ Interface for the connection of the keyswitch
⑬ Switch S2 *)
⑭ Equipotential bonding
*) Detailed description under "Interfaces" → "Description"
Image 2-3
Rear of the MCP 310 PN with Ethernet connecting cables
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
33
Machine control panel: MCP 310 PN
2.3 interfaces
Image 2-4
MCP 310 PN - MAC address/rating plate
2.3
interfaces
2.3.1
Overview
;
;
;
;
;
;
;
;
;
6
+
+
+
6
;
;
;
;
Image 2-5
Rear of the MCP 310 PN with interfaces
(1)
Equipotential bonding
X10
Power supply interface
X20
Ethernet port 1
X21
Ethernet port 2
X30
Interface for rotary switch feed override
X31
Interface for rotary switch spindle override / emergency stop (optional)
X51 / X52 / X55
Interfaces for customer-specific inputs
X53 / X54
Interfaces for customer-specific outputs
X60 / X61
Connections for 2 handwheels (TTL / differential - can be set with switch S1)
X70
Interface for connecting 16 direct keys
Machine control panels
34
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310 PN
2.3 interfaces
S1
Switch for setting the handwheel signal type
S2
Switch for setting the MCP address
LEDs
H1
POWER OK (green)
H2
BUSSYNC
H3
BUSFAULT
Equipotential bonding
The equipotential bonding conductor is attached by means of an M5 screw.
2.3.2
Description
Pin assignment
For more detailed information, see "General information and networking", Chapter:
"Connecting".
Switch S1/S2
Settings, see Chapter "Machine control panel: MCP 310C PN", Section "Interfaces".
2.3.3
Input / output images
Standard + two handwheels
The specifications for assigning input and output bytes listed in the tables can be changed in
the PLC via parameter assignment.
Note
The following applies in respect of the process input and output images in the tables: n is
defined by means of FB1 parameters in OB100 of the PLC.
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
35
Machine control panel: MCP 310 PN
2.3 interfaces
Table 2-1
Process input image for MCP 310 PN
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
EB n + 0
* NC
Spindle
Spindle
Spindle +
Single
JOG
MDA
AUTO
stop
100%
block
EB n + 1
NC
Spindle
* Spindle
Spindle
Keyswitch
REF
REPOS
Teach
start
right
stop
left
IN
position 3
EB n + 2
Feed
* Feed
INC VAR
Keyswitch
INC 1000
INC 100
INC 10
INC 1
start
stop
position 0
EB n + 3
RESET
Key-operated switch
Feedrate override
Position 2
Position 1
E (24)
D (23)
C (22)
B (21)
A (20)
EB n + 4
Arrow keys
KT-IN5
KT-IN4
KT-IN3
KT-IN2
KT-IN1
+
-
Rapid tra-
X52.2
X52.1
X51.3
X51.2
X51.1
verse
EB n + 5
T16
KT-IN6
Axis selection
X52.3
6
5
4
Z
Y
X
EB n + 6
Freely assignable customer keys
Freely assignable customer keys
T9
T10
T11
T12
WCS
T13
T14
T15
MCS
EB n + 7
Freely assignable customer keys
T1
T2
T3
T4
T5
T6
T7
T8
EB n + 8
DT8
DT7
DT6
DT5
DT4
DT3
DT2
DT1
EB n + 9
DT16
DT15
DT14
DT13
DT12
DT11
DT10
DT9
EB n + 10
KT-IN8
KT-IN7
KT-IN6
KT-IN5
KT-IN4
KT-IN3
KT-IN2
KT-IN1
X55.2
X55.1
X52.3
X52.2
X52.1
X51.3
X51.2
X51.1
EB n + 11
-
-
-
-
-
-
-
KT-IN9
X55.3
EB n + 12
-
-
-
-
-
-
-
-
EB n + 13
-
-
-
X31
X31
X31
X31
X31
pin 6 1)
pin 7 1)
pin 8 1)
pin 9 1)
pin 10 1)
Signals marked with * are inverse signals.
1)
If the 4-stage rotary spindle override switch on X31 is replaced by a 5-stage rotary switch, the input information here
can be measured in 5 stages.
Table 2-2
Input image for handwheel data
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
EB n + 14
Handwheel 1 counter status
(16-bit signed, low-order byte equals byte n+14)
EB n + 15
EB n + 16
Handwheel 2 counter status
(16-bit signed, low-order byte equals byte n+16)
EB n + 17
Machine control panels
36
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310 PN
2.3 interfaces
Within the SINUMERIK control, the handwheel data is processed directly by the NCK and is
not available to the PLC.
Table 2-3
Process output image for MCP 310 PN
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
AB n + 0
* NC
Spindle -
Spindle
Spindle +
Single
JOG
MDA
AUTO
stop
100%
block
AB n + 1
NC
Spindle
* Spindle
Spindle
RESET
REF.
REPOS
Teach
start
right
stop
left
IN
AB n + 2
Feed
* Feed
INC VAR
-
INC 1000
INC 100
INC 10
INC 1
start
stop
AB n + 3
-
-
-
-
-
-
-
-
AB n + 4
+
_
Rapid tra-
KT-OUT5
KT-OUT4
KT-OUT3
KT-OUT2
KT-OUT1
verse
X54.2
X54.1
X53.3
X53.2
X53.1
AB n + 5
T16
KT-OUT6
6
5
4
Z
Y
X
X54.3
AB n + 6
Freely assignable customer keys
T9
T10
T11
T12
WCS
T13
T14
T15
MCS
AB n + 7
Freely assignable customer keys
T1
T2
T3
T4
T5
T6
T7
T8
Signals marked with * are inverse signals
Default key assignment
-2*
REP
REF
VAR
7
7
7
Spindle
100
Spindle
Dec.
%
Inc.
MDA
Teach
7
1
7
7
7
Spindle
Spindle
Spindle
IN
Right
Stop
Left
Auto
7
7
10
7
7
7
X
Y
Z
Single
4th
5th
6th
Reset
7
100
7
7
7
Bliock
Axis
Axis
Axis
Cycle
Cycle
WCS
Feed
Feed
1000
-
Rapid
+
Stop
Start
MCS
Stop
Start
,QSXWV LQYHUWHG
7
7
XQODEHOHG NH\V
Image 2-6
Default key assignment of MCP 310 PN
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
37
Machine control panel: MCP 310 PN
2.4 Mounting
Assignment of the inputs (I) and outputs (O) to the keys and LEDs
,
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
2
,
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
2
,
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
2
,
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
2
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
,QSXWV LQYHUWHG
Image 2-7
Inputs and outputs of the MCP 310 PN keyboard
2.4
Mounting
Dimension drawing
Image 2-8
Dimension drawing for machine control panel MCP 310 PN
Machine control panels
38
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310 PN
2.5 Connecting
Tension jacks
The machine control panel is attached by means of 6 tension jacks (0.8 Nm; see dimension
drawing).
0RXQWLQJ SDQHO
6HDOLQJ DUHD
3UHVVXUH SRLQWV
IRU WHQVLRQ MDFNV
,Q WKH VHDOLQJ DUHD
Image 2-9
Panel cutout for machine control panel MCP 310 PN
Mounting position
Max. 60° to the vertical. For mounting positions greater than 60°, a fan must also be installed
to keep the ambient temperature of the machine control panel constantly below 55 °C.
2.5
Connecting
Two equivalent connections (Fast Ethernet) are available for Ethernet/PROFINET transfer.
The Ethernet cables are not included in the scope of delivery. They must be ordered separately.
The following components are recommended:
● Ethernet FastConnect cables
● Ethernet FastConnect connectors
More information on this can be found in the SIEMENS IK PI catalog.
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
39
Machine control panel: MCP 310 PN
2.6 Maintenance and Service
Securing Ethernet cables
Two cable ties are included in the scope of delivery. These are used to secure the Ethernet
cables on the cover plate at the rear of the machine control panel (see figure in Section: "Control
and display elements" → "Rear side").
NOTICE
Damaged cables caused by chafing edges
Make sure that all cables are routed so that they do not come into contact with chafing edges.
2.6
Maintenance and Service
Cleaning the device
Use a soft cloth moistened either with water or a mild cleaning agent to clean the housing and
operator control elements of the machine control panel.
Checking the device
In order to prevent foreign bodies or liquids entering the machine control panel, regularly check
the device
● that all the housing screws are in place and tight
● for damage to the housing
● for damage to the cable cover or cable entry
Protect the device from environmental effects
Protect the machine control panel against
● direct solar radiation and heat sources
● mechanical vibration and shock
● dust
● moisture, and
● strong magnetic fields
Check of the emergency stop button (if the emergency stop button has been retrofitted)
Check the emergency stop button regularly to ensure that it functions correctly.
Machine control panels
40
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310 PN
2.7 Technical data
2.7
Technical data
Machine control panel MCP 310 PN
Safety
Safety class
III; PELV according to EN 50178
Degree of protection ac-
Front side:
Key-operated
Rear side:
cording to EN 60529
IP65
switch:
IP00
IP54
Approvals
CE / cULus
Electrical data
Input voltage
24 VDC
Power consumption, max.
Board:
Lamps:
Handwheels:
Total:
5 W
14.4 W
2 x 0.9 W
21.2 W
(6 x 2.4 W) *)
Mechanical data
Dimensions
Width: 310 mm
Height: 175
Depth: 85.2 mm
mm
Mounting depth: 53.9 mm
Weight
Approx. 1.2 kg
*)
The outputs for the illuminated pushbuttons (X53/X54) can have a max. permissible current of 0.3 A.
However, the total current consumption of the components must not exceed 1.0 A (24 W).
Emergency Stop button
Rated voltage
24 VDC
Current magnitude, max.
3 A
Current magnitude, min.
1 mA
Switching capacity
DC 13 according to EN 60947-5-1
Conditional rated short-circuit current
10 A gL/gG according to EN 60947-5-1
B10d
500 000
Note
The quantitative assessment of the emergency stop safety function must be based on the
B10d values corresponding to the used standards (e.g. ISO 13849-1) under consideration of
the respective application (frequency of the actuation, service life, diagnostics by the evaluation
unit, etc.). The B10d values only apply when the technical properties of the emergency stop
button are taken into account.
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
41
Machine control panel: MCP 310 PN
2.8 Accessories and spare parts
2.8
Accessories and spare parts
2.8.1
Overview
Table 2-4
Accessories and spare parts for machine control panel 310 PN
Name
Description
Quanti-
Article number
ty
Key-operated switch
Key-operated switch with key
1
6FC5247-0AF02-0AA0
Sets of keys
Ten key sets, each with three keys for the keyswitch settings
1
6FC5148-0AA03-0AA0
1, 2, 3
set
Set of tension jacks
Tension jack set (9 items) for supplementary components with
1
6FC5248-0AF14-0AA0
2.5 mm profile, length 20 mm
set
Override, spindle
Override spindle / rapid traverse, electronic rotary switch
1
6FC5247-0AF12-1AA0
rotary switch
1x16G, T=24, cap, button, pointer, spindle dials and rapid tra-
verse
Override, feed
Feed / rapid traverse override, electronic rotary switch 1x23G,
1
6FC5247-0AF13-1AA0
rotary switch
T=32, cap, button, pointer, feed and rapid-traverse dials
Emergency Stop but-
22 mm actuating element, emergency stop mushroom-head
1
3SB3000-1HA20 *)
ton
pushbutton, red, mushroom head and support
Contact block with 2 contacts, 1 NO + 1 NC, 2-pole ,screw ter-
1
3SB3400-0A *)
minal
Slide-in labels
3 DIN A4 films that can be labeled
1 set
6FC5248-0AF23-1AA0
Cable set
60 cables for additional MCP control devices, 500 mm long
1 set
6FC5247-0AA35-0AA0
Signal cable, handwheel
Connecting cable for the handwheel, max. length: 5 m
1
6FX8002-2CP00-1Axy
xy is the length code:
x (m) = A (0) ...F (5); y (dm) = 0 ... 8
For details, see Image 1-8 Connection cable for COM board
handwheel (Page 28).
*) Safety-related
Machine control panels
42
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310 PN
2.8 Accessories and spare parts
2.8.2
Labeling the slide-in labels
You can create your own slide-in labels to label the keys differently. Use the blank films that
can be printed for this purpose.
① Print direction
Image 2-10 Blank film for MCP 310 PN
Files for printing the blank film
The DOConCD or CD included in Catalog NC 61/ NC 62 contains three files for printing the
blank films:
● Template_M_MCP310.doc [defaults for milling - standard shipped file; (A)]
● Template_MCP310.doc (blank template for film: Item No. A5E00205580; (B)]
● Symbols.doc Key symbols as Word file, inscription on labels as jpg file (C)
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
43
Machine control panel: MCP 310 PN
2.8 Accessories and spare parts
①
Outer edges
Image 2-11 Template_M_MCP310.doc for the "Milling" version (A)
Image 2-12 Template_MCP310.doc (acc. to labeling plan /template: Item No. A5E00205580 (B)]
Machine control panels
44
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310 PN
2.8 Accessories and spare parts
Table 2-5
Symbols.doc file (C)
7001
7013
7025
7124
7002
7014
7026
7125
&
7003
7015
7027
7126
;
7004
7016
7028
7127
=
<
7005
7017
7029
7128
=
7006
7018
7030
7129
;
7007
7019
7031
7130
<
7008
7020
7032
7131
=
7009
7021
7033
7132
&
7010
7022
7120
<
7011
7023
7121
;
7012
7024
7123
Creating slide-in labels with the aid of the file: "Template_M_MCP310.doc" (A)
Open the file Template_M_MCP310.doc in the word-processing program MS Word.
To obtain an optimum printing result, remove all separating lines in each slide-in label ②
above, below and between the symbols.
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
45
Machine control panel: MCP 310 PN
2.8 Accessories and spare parts
Do not highlight the slide-in labels using the table symbol
①, but instead:
1. Place the cursor directly before the first symbol on the first slide-in label.
2. Highlight the entire row of the slide-in label by
- pressing and holding the left mouse key and dragging it to the end of the row or
- pressing the F8 key and the cursor key "→" until the entire row is selected.
3. Click on the highlighting with the right mouse key.
4. In the menu that appears, select the entry: "Table properties".
5. On the "Table" tab, select the entry: "Borders and shading…".
6. Select the tab "Borders" and click on "Setting:" in the symbol with the designation: "None".
7. Confirm the selection with "OK" → "OK" and remove the highlighting.
This removes all separating lines (with the exception of the outer edges) from this row.
2XWHU HGJHV
8. Remove the separating lines of the other slide-in labels in the same way.
9. Place the blank film in the printing direction in the slot of your laser printer (see diagram,
"Blank film MCP 310 PN").
10.Select "film" as the printable medium if your printer allows this setting.
11.Start the printing process using MS Word.
Note
For labeling the slide-in labels, HP Color Laser Jet film C2936A is used.
Make a test print on paper before you print on the film.
Allow the film to cool after printing so that the ink can dry.
12.Cut the slide-in labels out of the film along the edges.
13.Round off the corners of the slide-in labels approx. 1.5 mm to facilitate insertion.
Preparing the slide-in labels with the aid of "Template_MCP310.doc" (B)
Inserting symbols with the"Symbols.doc" file (C)
1. Open both the "Template_MCP310.doc" file and the "Symbols.doc" file in MS Word.
2. Copy the desired key symbol from the file "Symbols.doc".
3. Position the cursor in the desired field of the template (B) and add the symbol.
4. If all the desired symbols have been added, remove the separating lines and start the
printing process in accordance with the instructions in Section: Preparing the slide-in labels
with the aid of "Template_M_MCP310.doc".
Machine control panels
46
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310 PN
2.8 Accessories and spare parts
Inserting characters/text
1. Open the "Template_MCP310.doc" file in MS Word.
2. Set the "Arial" font to format characters.
(This font is comparable to the "Univers S57" font, used by Siemens for the key labeling.)
3. Position the cursor in the desired table cell and enter characters/text.
Creating your own symbols
● Printing in a vector program (e.g. Designer, Freehand, CorelDraw):
- Draw a 15 x 15 mm square, fill with the color white and give it an invisible border line.
- Place the symbol in the center of this square.
- Copy the entire image (square and symbol) and paste it into the Word document
(Template_MCP310.doc).
● Drawing in an image editing program (e.g. Photoshop, Picture Publisher, Paint):
- Create a square area (e.g. 100 x 100 pixels) filled with the color white.
- Draw the symbol in the center of this square.
- Copy the entire image (square and symbol) and paste it into the Word document
(Template_MCP310.doc).
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
47
Machine control panel: MCP 310 PN
2.8 Accessories and spare parts
Dimension drawings
The figure shows a dimension drawing for the MCP 310 PN blank template:
1DUURZ ODEHO ZLGWK
FP
KHLJKW
FP
+HLJKW
FP
+HLJKW
FP
+HLJKW
FP
+HLJKW
FP
+HLJKW
FP
+HLJKW
FP
+HLJKW
FP
:LGWK
FP
:LGWK
FP
:LGWK
FP
Image 2-13 Dimension drawing for MCP 310 PN slide-in labels
2.8.3
Inserting the slide-in label "Part1"
The slide-in label "Part1" (8) is located under the grounding bracket (1).
Therefore, first remove the grounding bracket before you pull out or insert the slide-in label
"Part 1".
Machine control panels
48
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310 PN
2.8 Accessories and spare parts
(1)
Grounding bracket
(2)
Fastening screws (M3) for the grounding bracket (housing)
(3)
Fastening screw (M5) for the grounding bracket (COM board)
(4)
Slide-in labels "Part5"
(5)
Slide-in labels "Part4"
(6)
Slide-in labels "Part3"
(7)
Slide-in labels "Part2"
(8)
Slide-in labels "Part1"
Image 2-14 MCP 310 PN - Rear with slide-in labels
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
49
Machine control panel: MCP 310 PN
2.8 Accessories and spare parts
Removing the grounding bracket
1.Remove the fastening screw (M5) using a TX
25 screwdriver.
2.Remove the two fastening screws (M3) using
a TX 10 screwdriver.
3.Take off the grounding bracket.
Machine control panels
50
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310 PN
2.8 Accessories and spare parts
4.Pull out the slide-in label.
Installing the grounding bracket
Secure the grounding bracket after you have inserted the slide-in label by tightening the three
fastening screws.
Note
Observe the proper torque values when tightening the screws:
- M3: 0.8 to 1.3 Nm
- M5: 3.0 to 6.0 Nm
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
51
Machine control panel: MCP 310 PN
2.8 Accessories and spare parts
Machine control panels
52
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310
3
3.1
Description
The machine control panel MCP 310 permits user-friendly and clear operation of the machine
functions. It is suitable for machine-level operation of milling, turning, grinding and special
machines.
49 keys have user-inscribed slide-in labels for machine-specific adaptations. A DIN A4 film for
labeling the slide-in strips is included in the delivery kit.
A connecting cable is included in the scope of delivery for connecting the direct keys of the
SINUMERIK OP 012 / OP 015A and TP 015A operator panel fronts.
The machine control panel is secured from the rear using special clamps supplied with the
panel.
Validity
The description applies to the MCP 310 operator panel front.
Article number: 6FC5203-0AF23-1AA0
The safety-related accessories / spare parts are marked in the "Accessories and spare parts"
section with a *).
Features
Operator controls
● Membrane keys
● Operating mode and function keys:
-
49 keys with LEDs, 16 freely assignable customer keys in the standard assignment
- Direction keys for milling machines with rapid traverse override
● Feed control with override feed / rapid traverse (rotary switch with 23 positions)
● Key-operated switch (four positions and three different keys)
Interfaces:
● PROFIBUS DP
● For 6 control devices (6 inputs / 6 outputs)
(additional cable set required for control devices; see Section: "Accessories and spare
parts".)
● For 16 direct control keys for OP 012 / OP 015A and TP 015A when connected via
PROFIBUS DP (connection cable: 850 mm, included in scope of delivery)
● For 2 handwheels when connected via PROFIBUS DP (max. cable length: 5 m)
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
53
Machine control panel: MCP 310
3.2 Operating and display elements
Expansion slots:
● Six slots for control devices (d = 16 mm)
● One slot for emergency stop button or rotary override switch (to d = 22 cm)
3.2
Operating and display elements
3.2.1
Front side
Overview
① Operating modes and machine functions
② Customer keys (T1 to T16)
③ Spindle control
④ Slot for Emergency-Stop button or spindle override rotary switch
⑤ Feed control with override rotary switch
⑥ Slots for control devices 16 mm
⑦ Program control
⑧ Key-operated switch
Image 3-1
Position of control elements on machine control panel MCP 310
Machine control panels
54
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310
3.2 Operating and display elements
Emergency Stop button
If an EMERGENCY STOP button is added: See Section Front side (Page 120).
Slots for control devices
NOTICE
Damage to the front
The openings for mounting control devices must not be knocked out, but drilled to the required
width.
Information for the installation, or to select control devices, please refer to the following Section:
Front side (Page 31).
3.2.2
Rear side
COM board
The control and display elements on the rear of the MCP 310 are located on the COM board
(shown with a gray backg5round in the illustration).
The detailed cutout under or above the interface name shows the position of pin 1 on the
connectors.
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
55
Machine control panel: MCP 310
3.3 Interfaces
;
;
;
+
+
;
;
;
6
;
&20 %RDUG
(TXLSRWHQWLDO ERQGLQJ
6
H\ RSHUDWHG VZLWFK
;
;
;
;
;
Image 3-2
Rear of the MCP 310 showing the control and display elements and the interfaces
Description of rear control and display elements
See Chapter “Machine control panel MCP 483 (Page 122)”.
3.3
Interfaces
3.3.1
Overview
Location of the interfaces
MCP 310 communication is handled by the COM board where the interfaces are located (see
Rear side (Page 55)).
Machine control panels
56
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310
3.3 Interfaces
Pin assignment
For more detailed information, see "General information and networking", Chapter:
"Connecting".
3.3.2
Settings via DIP switch S3
Delivery condition
Table 3-1
Delivery condition setting
1
2
3
4
5
6
7
8
9
10
Meaning/value
on
off
on
off
on
on
off
off
off
off
Series
Note
The delivery condition setting MUST be changed in accordance with the "Assignment of the
DIP switch S3" table (below).
Connection type: PROFIBUS DP
For PROFIBUS DP, the PROFIBUS address is set using switches 1 to 10:
Table 3-2
Assignment of DIP switch S3
1
2
3
4
5
6
7
8
9
10
Meaning/value
PROFIBUS
off
off
off
off
off
off
off
-
on
on
0
on
off
off
off
off
off
off
-
on
on
1
off
on
off
off
off
off
off
-
on
on
2
on
on
off
off
off
off
off
-
on
on
3
:
:
:
:
:
:
:
-
-
-
: (etc.)
on
off
on
on
on
on
on
-
on
on
125
off
on
on
on
on
on
on
-
on
on
126
3.3.3
Input / output images
The specifications for assigning input and output bytes listed in the tables can be changed in
the PLC via parameter assignment.
Note
The following applies in respect of the process input and output images in the tables: n is
defined by means of FB1 parameters in OB100 of the PLC.
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
57
Machine control panel: MCP 310
3.3 Interfaces
Table 3-3
Input image MCP 310 - standard
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
n + 0
* CYCLE
SPINDLE
100 %
SPINDLE
SINGLE
JOG
MDA
AUTO
STOP
DEC. -
INC. +
BLOCK
n + 1
CYCLE
SPINDLE
* SPINDLE
SPINDLE
Keyswitch
REF.
REPOS
TEACH IN
START
RIGHT
STOP
LEFT
position 3
n + 2
FEED
* FEED
INC [VAR]
Keyswitch
INC 1000
INC 100
INC 10
INC 1
START
STOP
position 0
n + 3
Key-operated switch
Feedrate override
RESET
Position 2
Position 1
OV_VS16
OV_VS8
OV_VS4
OV_VS2
OV_VS1
X30.6
X30.7
X30.8
X30.9
X30.10
n + 4
Traversing direction
RAPID
KT-IN5
KT-IN4
KT-IN3
KT-IN2
KT-IN1
X52.2
X52.1
X51.3
X51.2
X51.1
+
-
n + 5
T16
KT-IN6
Axis selection
X52.3
6
5
4
Z
Y
X
n + 6
Freely assignable customer keys
WCS MCS
Freely assignable customer keys
T9
T10
T11
T12
T13
T14
T15
n + 7
Freely assignable customer keys
T1
T2
T3
T4
T5
T6
T7
T8
*
Inverse signals
Table 3-4
Input image MCP 310 - supplementary I/O
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
m + 0
DT8
DT7
DT6
DT5
DT4
DT3
DT2
DT1
m + 1
DT16
DT15
DT14
DT13
DT12
DT11
DT10
DT9
m + 2
-
-
-
-
-
-
-
-
m + 3
-
-
-
OV_VS16
OV_VS8
OV_VS4
OV_VS2
OV_VS1
X30.6
X30.7
X30.8
X30.9
X30.10
m + 4
-
-
-
OV_SP16
OV_SP8
OV_SP4
OV_SP2
OV_SP1
X31.6 1)
X31.7 1)
X31.8 1)
X31.9 1)
X31.10 1)
1)
The input information about optional spindle override rotary switches, max. 5-stage can be retrieved here.
Table 3-5
Input image MCP 310 - handwheel
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
p + 0
Counter status, handwheel 1 at X60
(16 bits signed, in the big endian format)
p + 1
p + 2
Counter status, handwheel 2 at X61
(16 bits signed, in the big endian format)
p + 3
Machine control panels
58
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310
3.3 Interfaces
Note
Within the SINUMERIK control, the handwheel data is processed directly by the NCK and is
not available to the PLC.
Table 3-6
MCP 310 output image
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
n + 0
CYCLE
SPINDLE
100 %
SPINDLE
SINGLE
JOG
MDA
AUTO
STOP
DEC. -
INC. +
BLOCK
n + 1
CYCLE
SPINDLE
SPINDLE
SPINDLE
RESET
REF.
REPOS
TEACH IN
START
RIGHT
STOP
LEFT
n + 2
FEED
FEED
INC [VAR]
-
INC 1000
INC 100
INC 10
INC 1
START
STOP
n + 3
-
-
-
-
-
-
-
-
n + 4
Traversing direction
RAPID
KT-OUT5
KT-OUT4
KT-OUT3
KT-OUT2
KT-OUT1
X54.2
X54.1
X53.3
X53.2
X53.1
+
-
n + 5
T16
KT-OUT6
6
5
4
Z
Y
X
X54.3
n + 6
Freely assignable customer keys
WCS MCS
Freely assignable customer keys
T9
T10
T11
T12
T13
T14
T15
n + 7
Freely assignable customer keys
T1
T2
T3
T4
T5
T6
T7
T8
Table 3-7
Output image MCP 310 - supplementary I/O
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
m + 0
Reserved
m + 1
Reserved
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
59
Machine control panel: MCP 310
3.3 Interfaces
Default key assignment
-2*
REP
REF
VAR
7
7
7
Spindle
100
Spindle
Dec.
%
Inc.
MDA
Teach
7
1
7
7
7
Spindle
Spindle
Spindle
IN
Right
Stop
Left
Auto
7
7
10
7
7
7
X
Y
Z
Single
4th
5th
6th
Reset
7
100
7
7
7
Bliock
Axis
Axis
Axis
Cycle
Cycle
WCS
Feed
Feed
1000
-
Rapid
+
Stop
Start
MCS
Stop
Start
,QSXWV LQYHUWHG
7
7
XQODEHOHG NH\V
Image 3-3
MCP 310 default key assignment
Assignment of the inputs (I) and outputs (O) to the keys and LEDs
,
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
2
,
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
2
,
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
2
,
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
2
,
,
,
,
,
,
,
,
,
2
2
2
2
2
2
2
2
2
,QSXWV LQYHUWHG
Image 3-4
Inputs and outputs of the MCP 310 keyboard
Machine control panels
60
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310
3.4 Mounting
3.4
Mounting
Dimension drawing
Image 3-5
Dimension drawing for machine control panel MCP 310
Tension jacks
The machine control panel is attached by means of 6 tension jacks (0.8 Nm; see dimension
drawing).
0RXQWLQJ SDQHO
6HDOLQJ DUHD
3UHVVXUH SRLQWV
IRU WHQVLRQ MDFNV
,Q WKH VHDOLQJ DUHD
Image 3-6
Panel cutout for machine control panel MCP 310
Mounting position
Max. 60° to the vertical. For mounting positions greater than 60°, a fan must also be installed
to keep the ambient temperature of the machine control panel constantly below 55° C.
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
61
Machine control panel: MCP 310
3.5 PROFIBUS communication
3.5
PROFIBUS communication
3.5.1
Overview
This section describes:
● Requirements for adding a DP slave MCP to the hardware configuration for a SIMATIC S7
project.
● Configuring a DP slave MCP with STEP7 "HW config."
● Details of how to link the DP slave MCP to the basic PLC program and user program
(optional).
Note
The instructions given in this chapter are essentially limited to the special requirements for
configuring the DP slave MCP. For more details about working with SIMATIC STEP 7
please refer to the relevant SIMATIC documentation or online help.
Note
Both units can be linked up using the supplied 20-pin ribbon cable in order to transfer the
direct key signals of the operator panel front to the COM board of the machine control panel.
The direct key module therefore no longer needs to be connected.
3.5.2
Prerequisites
The following components are needed as prerequisites for adding a DP slave MCP to the
hardware configuration:
● SIMATIC STEP 7 as of Version 5.4, Service Pack 4
● Toolbox 840D sl as of Version 2.6
Hardware configuration
The DP slave MCP is shown in SIMATIC STEP 7 in the hardware catalog of “HW Config” under
the following path:
Profile: Standard
PROFIBUS DP > Other field devices > NC/RC > Motion Control > SINUMERIK MCP
If the module is not displayed, the GSD file must be installed. To do this, in "HW config" use
menu command Tools > Install new GSD file.
Note
The GSD file of the DP slave MCP is located on the Toolbox CD in the directory:
...\8x0d\GSD\MCP_310_483
Machine control panels
62
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310
3.5 PROFIBUS communication
3.5.3
Functions of the machine control panel
The machine control panel offers the following functions:
● Standard
The input/output data of the function keys and user-specific keys and outputs are
transferred:
- Input data: 8 bytes
- Output data: 8 bytes
● Handwheel
The absolute values of the two handwheels that can be connected to the machine control
panel are transferred.
● Additional I/Os
The data of the following non-default inputs/outputs is transferred:
- Direct keys
- Customer keys
- Rotary switch
3.5.4
Configuring the DP slave MCP
This section describes how to configure a DP slave MCP with reference to the hardware
configuration for a SIMATIC S7 project shown in the figure by way of example.
The hardware configuration has the following modules:
● SIMATIC Station 300 with SINUMERIK 840D sl
● SINUMERIK MCP with module: Standard + handwheel + additional I/O
Procedure
Configuring the DP slave MCP as an S7 project involves the following steps:
1. Add the DP slave MCP to the configuration ①.
2. Set the PROFIBUS address.
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
63
Machine control panel: MCP 310
3.5 PROFIBUS communication
3. Add the appropriate module to the DP slave MCP depending on the required functions
②.
4. Set the I/O addresses of the individual slots.
Image 3-7
Configuration with DP slave MCP
Requirements: S7 project
The following status is required for the S7 project to which the DP slave MCP is to be added:
● The S7 project has been created.
● A SIMATIC 300 station with SINUMERIK controller has been defined.
Adding a DP slave MCP
To add a DP slave MCP to the configuration, open the hardware catalog using the menu
command View > Catalog.
The DP slave MCP can be found at profile: Standard
PROFIBUS DP > Other field devices > NC/RC > Motion Control > SINUMERIK MCP
Click with the left mouse button on the DP slave MCP (SINUMERIK MCP) in the hardware
catalog and drag it onto the DP master system in the station window by holding down the left
mouse button.
The DP master system is displayed in the station window with the following symbol:
Machine control panels
64
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310
3.5 PROFIBUS communication
When you release the left mouse button, the DP slave MCP is added to the configuration.
Note
As you drag the DP slave the cursor appears as a circle with a slash through it. When the
cursor is positioned exactly over the DP master system, it changes to a plus sign, and the DP
slave can be added to the configuration.
PROFIBUS parameters
As soon as you have inserted the MCP DP slave into the configuration, the "Properties -
PROFIBUS interface SINUMERIK MCP" dialog box is displayed:
Dialog: Properties - PROFIBUS interface SINUMERIK MCP
Tab card: Parameters
Address: <PROFIBUS address>
Button: "Properties..."
Dialog: PROFIBUS properties
Tab card: Network settings
Data transfer rate: 12 Mbaud
Profile: DP
OK
OK
The following PROFIBUS parameters must either be set or verified:
● PROFIBUS address
● Data transfer rate
● Profile
Note
No automatic comparison of the PROFIBUS address!
The PROFIBUS address of the DP slave MCP set in the S7 project must match the
PROFIBUS address set on the module (DIP switch S3) (see Section: "Settings via DIP
switch S3")
The following data must agree:
1. SIMATIC S7 configuration DP slave MCP: PROFIBUS address
2. Machine control panel DIP switch S3: PROFIBUS address
3. FB1 call in OB100: "MCP1BusAdr := "
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
65
Machine control panel: MCP 310
3.5 PROFIBUS communication
Adding a module
The active functions and hence the number of user data elements to be transferred are chosen
by selecting the appropriate pre-configured module. The following modules are available in
HW Config under "SINUMERIK MCP":
● Universal module (not applicable)
● Standard
● Standard + handwheel
● Standard + additional I/O
● Standard + handwheel + additional I/O
I/O addresses
If you add a module to slot 1 of the DP slave MCP, the I/O addresses are automatically assigned
by STEP 7.
Double clicking with the left mouse button on a slot opens the "Properties - DP Slave" dialog
box. This dialog box can be used to set the start addresses of the I/O data of the slot.
3.5.5
Linking the DP slave MCP
This chapter describes how to link the DP slave MCP
● in the basic PLC program for transferring the standard input/output data in the VDI interface
● to the PLC user program (optional) to implement a user-specific response to a module failure
Note
Processing of additional I/O data is the sole responsibility of the user (machine
manufacturer) and is not supported by the PLC basic program.
PLC basic program
To transfer the standard I/O data of the MCP DP slave via the PLC basic program, the
corresponding I/O range must be entered in the communication parameters of the FB1 function
block.
Function block FB1
The communications parameters of the MCP are called MCPx... (x = 1 or 2) in function block
FB1. A maximum of 2 machine control panels are supported by the basic PLC program.
To synchronize several MCPs, the PLC program must be adapted accordingly. This is the
user's (machine manufacturer's) responsibility.
Machine control panels
66
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310
3.5 PROFIBUS communication
To operate an MCP 310 machine control panel as DP slave, only the parameters listed in the
following table are relevant for the FB1 call in the OB100:
Parameters
Type
Description
Value
MCPNum:
INT
Number of active MCPs
:=1
MCP1In:
POINTER
Start address of the input signals
:= P#E 0.0
MCP1Out:
POINTER
Start address of the output signals
:= P#A 0.0
MCP1StatSend
POINTER
Status data word for sending
:= P#A 8.0
MCP1StatRec
POINTER
Status data word for receiving
:= P#A 12.0
MCP1BusAdr
INT
≙ S3 switch position on the MCP
:=6
MCP1Timeout
S5time
Cyclic sign-of-life monitoring of the MCP
:= S5T#700MS
MCP1Cycl
S5time
Time reference for the cyclic updating of the signals to the MCP
:= S5T#200MS
MCPBusType
BYTE
33 ≙ PROFIBUS (55 ≙ Ethernet)
:= B#16#33
VDI interface parameter assignment
The following function blocks are available for assigning the VDI interface parameters:
● FC 24: Transfer the signals for narrow MCP, M (milling) version
● FC 25: Transfer the MCP signals, T (turning) version
Note
The FC 19, FC 24 and FC 25 function blocks are part of the basic PLC program. It is the
user's (machine manufacturer's) responsibility to call the block correctly and/or assign the
interface the appropriate parameters.
References
A detailed description of the function blocks for transferring the machine control panel signals
is available in:
Function Manual, Basic Functions: P3, Basic PLC Program
PLC user program
If an MCP is connected via PROFIBUS DP, the basic PLC program does not check for module
failure.
In this case the MCP is monitored by a standard mechanism to monitor the active DP slave:
● PLC operating system
● PROFIBUS controller
If a failure of a DP slave MCP is detected, the PLC defaults to STOP.
Customized response
The following organization blocks can be added to the PLC user program to customize the
response to a DP slave MCP failure:
● OB 82: Diagnostics interrupt
● OB 86: Rack failure
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
67
Machine control panel: MCP 310
3.6 Maintenance and Service
Please refer to the corresponding SIMATIC literature for details of linking organization blocks
and evaluating diagnostic data.
Note
In the event of a failure of a connected machine control panel, the PLC basic program performs
the following:
● Alarm "40026x machine control panel (x+1) failure"; with x = 0, 1 is initiated.
● The corresponding interface signal "MCP 1/2 ready" in the DB10.DBB104 is reset.
3.6
Maintenance and Service
Cleaning the device
Use a soft cloth moistened either with water or a mild cleaning agent to clean the housing and
operator control elements of the machine control panel.
Checking the device
In order to prevent foreign bodies or liquids entering the machine control panel, regularly check
the device
● that all the housing screws are in place and tight
● for damage to the housing
● for damage to the cable cover or cable entry
Protect the device from environmental effects
Protect the machine control panel against
● direct solar radiation and heat sources
● mechanical vibration and shock
● dust
● moisture, and
● strong magnetic fields
Check of the emergency stop button (if the emergency stop button has been retrofitted)
Check the emergency stop button regularly to ensure that it functions correctly.
Machine control panels
68
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310
3.7 Diagnostics
3.7
Diagnostics
3.7.1
LED displays
LEDs H1 to H5 on the COM board provide information about the following states:
Diagnostics
H1
H3
H4
H5
Power On
Lights up red
Lights up green
Lights up or-
Lights up red/off
ange
The LEDs light up for approx. 4 s.
GD communication
Off
Lights up green
Flashes orange
Lights up red
(80 Hz)
There is no PROFIBUS com-
Lights up red
Lights up green
Off
Flashes green
munication.
(bus error)
(approx. 25 Hz)
MCP is configured as PROFI-
Off
Lights up green
Off/orange
Lights up green
BUS slave and with cyclic data
exchange.
Fatal error LED display
flashes red
flashes green
flashes orange
flashes green
For fatal software errors and incorrect DIP switch settings, the LEDs
flash very quickly.
LED H2 is reserved for service and is always off.
+
+
+
+
+
Image 3-8
Arrangement of the LEDs on the COM board
3.7.2
Output functions
Preconditions
● The MCP is booting.
● The MCP is not communicating with the control system/ PROFIBUS master, i.e. all of the
LEDs in the keys are flashing.
In this state, the output functions described in the following can be sequentially called.
1. Software version
Simultaneously press the "FEED START" and "FEED STOP" keys.
The software version is output using three digits. The individual digits are expressed by the
number of LEDs in the keys that are switched on.
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
69
Machine control panel: MCP 310
3.7 Diagnostics
)(('
)(('
6723
67$57
①
1. Digit of the software version
②
2. Digit of the software version
③
3. Digit of the software version
Image 3-9
Example: Output of the actual software version "03.01.00.00"
2. Output of the bus address
Keep the FEED keys pressed, and in addition press the WCS MCS" key.
The actual bus address of the MCP is output by the number of LEDs in the keys that are
switched on:
PROFIBUS: Value range 0 … 126
MPI: Value range 0 … 15
)(('
)(('
:&6 0&6
6723
67$57
① Hundreds position of the bus address
② Tens position of the bus address
③ Ones position of the bus address
Image 3-10 Example: Output of PROFIBUS address "28"
3. Output of the bus system
Keep the FEED keys pressed, and press the WCS MCS" key again.
The LEDs in the keys indicate the bus system in which the MCP is integrated: MPI or
PROFIBUS (PB).
Machine control panels
70
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310
3.7 Diagnostics
)(('
)(('
:&6 0&6
6723
67$57
Image 3-11 Example: Output of the bus system "PB" (PROFIBUS)
3.7.3
Key test
Preconditions
● The MCP is booting.
● The MCP is not communicating with the control system/ PROFIBUS master, i.e. all of the
LEDs in the keys are flashing.
In this state, the operating functions described in the following can be executed in the test
mode.
Test mode
● Activation: Press the "RESET" key.
● Automatic deactivation: No operator control was pressed in the last 3 seconds.
● Manual deactivation: Simultaneously press the "CYCLE STOP" and "CYCLE START" keys.
Operating functions
● Function of the keys and their associated LEDs:
When pressing a key, the associated LED is switched on.
● Function of the rotary switch
Each time the rotary switch is turned, an LED is switched on in sequence in the form of a
running light.
● Function of the key-operated switch:
When the key-operated switch is turned, positions 0 - 3 are displayed by 0 up to three LEDs.
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
71
Machine control panel: MCP 310
3.8 Technical data
3.8
Technical data
Machine control panel MCP 310
Safety
Safety class
III; PELV according to EN 50178
Degree of protection accord-
Front side:
Key-operated switch:
Rear side:
ing to EN 60529
IP65
IP54
IP00
Approvals
CE
Electrical data
Input voltage
24 VDC
Power consumption, max.
Board:
Lamps:
Handwheels:
Total:
7 W
14.4 W (6 x 2.4 W) *)
2 x 0.9 W
23.2 W
Mechanical data
Dimensions
Width: 310 mm
Depth: 65 mm
Height: 175 mm
Mounting depth: 33 mm
Distance from NCU/PCU
PROFIBUS DP: 100 m
Weight
Approx. 1.2 kg
*) The outputs for the illuminated pushbuttons (X53/X54) can have a max. permissible current of 0.3 A.
However, the total current consumption of the components must not exceed 1.0 A (24 W).
Note
Information about the climatic and mechanical environmental conditions is contained in the
associated section under:
"General notes and interconnection" → "Operational planning".
Emergency Stop button
Rated voltage
24 VDC
Current magnitude, max.
3 A
Current magnitude, min.
1 mA
Switching capacity
DC 13 according to EN 60947-5-1
Conditional rated short-circuit current
10 A gL/gG according to EN 60947-5-1
B10d
500 000
Note
The quantitative assessment of the emergency stop safety function must be based on the
B10d values corresponding to the used standards (e.g. ISO 13849-1) under consideration of
the respective application (frequency of the actuation, service life, diagnostics by the evaluation
unit, etc.). The B10d values only apply when the technical properties of the emergency stop
button are taken into account.
Machine control panels
72
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310
3.9 Accessories and spare parts
3.9
Accessories and spare parts
3.9.1
Overview
Table 3-8
Accessories and spare parts for machine control panel 310
Name
Description
Qua
Article number
ntity
Keyswitch
Keyswitch with key
1
6FC5247-0AF02-0AA0
Sets of keys
Ten key sets, each with three keys for the
1
6FC5148-0AA03-0AA0
keyswitch settings 1, 2, 3
set
Set of tension jacks
Tension jack set (9 items) for supplementary
1
6FC5248-0AF14-0AA0
components with 2.5 mm profile, length 20
set
mm
Override
Override spindle / rapid traverse, electronic
1
6FC5247-0AF12-1AA0
for rotary
rotary switch 1x16G, T=24, cap, button, point-
spindle switch
er, spindle dials and rapid traverse
Rotary feed
Feed / rapid traverse override, electronic ro-
1
6FC5247-0AF13-1AA0
override
tary switch 1x23G, T=32, cap, button, pointer,
switch
feed and rapid-traverse dials
22 mm actuating element, emergency stop
1
3SB3000-1HA20 *)
Emergency stop
button, red, mushroom head and support
button
Contact block with 2 contacts, 1 NO + 1 NC,
1
3SB3400-0A *)
2-pole ,screw terminal
Slide-in
Slide-in label, (3 films, DIN A4)
1 set
6FC5248-0AF23-1AA0
labels
Cable set for addi-
Cable set for additional control devices
1 set
6FC5247-0AA35-0AA0
tional control devi-
Length: 500 mm
ces
*) Safety-related
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
73
Machine control panel: MCP 310
3.9 Accessories and spare parts
3.9.2
Labeling the slide-in labels
You can create your own slide-in labels to label the keys differently. Use the blank films that
can be printed for this purpose.
① Print direction
Image 3-12 Blank film for MCP 310
Machine control panels
74
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310
3.9 Accessories and spare parts
Files for printing the blank film
The DOConCD or CD included in Catalog NC 61/ NC 62 contains three files for printing the
blank films:
● Template_M_MCP310.doc [defaults for milling - standard shipped file; (A)]
● Template_MCP310.doc (blank template for film: Item No. A5E00205580; (B)]
● Symbols.doc Key symbols as Word file, inscription on labels as jpg file (C)
①
Outer edges
Image 3-13 Template_M_MCP310.doc for the "Milling" version (A)
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
75
Machine control panel: MCP 310
3.9 Accessories and spare parts
Image 3-14 Template_MCP310.doc (acc. to labeling plan /template: Item No. A5E00205580 (B)]
Table 3-9
Symbols.doc file (C)
7001
7013
7025
7124
7002
7014
7026
7125
&
7003
7015
7027
7126
;
7004
7016
7028
7127
=
<
7005
7017
7029
7128
=
7006
7018
7030
7129
;
7007
7019
7031
7130
<
7008
7020
7032
7131
=
7009
7021
7033
7132
&
7010
7022
7120
<
Machine control panels
76
Manual, 03/2016, 6FC5397-1AP40-5BA3
Machine control panel: MCP 310
3.9 Accessories and spare parts
7011
7023
7121
;
7012
7024
7123
Creating slide-in labels with the aid of the file: "Template_M_MCP310.doc" (A)
Open the file Template_M_MCP310.doc in the word-processing program MS Word.
To obtain an optimum printing result, remove all separating lines in each slide-in label ②
above, below and between the symbols.
Do not highlight the slide-in labels using the table symbol ①, but instead:
1. Place the cursor directly before the first symbol on the first slide-in label.
2. Highlight the entire row of the slide-in label by
- pressing and holding the left mouse key and dragging it to the end of the row or
- pressing the F8 key and the cursor key "→" until the entire row is selected.
3. Click on the highlighting with the right mouse key.
4. In the menu that appears, select the entry: "Table properties".
5. On the "Table" tab, select the entry: "Borders and shading…".
6. Select the tab "Borders" and click on "Setting:" in the symbol with the designation: "None".
7. Confirm the selection with "OK" → "OK" and remove the highlighting.
This removes all separating lines (with the exception of the outer edges) from this row.
2XWHU HGJHV
8. Remove the separating lines of the other slide-in labels in the same way.
9. Place the blank film in the printing direction in the slot of your laser printer (see diagram,
"Blank film MCP 310").
10.Select "film" as the printable medium if your printer allows this setting.
11.Start the printing process using MS Word.
Note
For labeling the slide-in labels, HP Color Laser Jet film C2936A is used.
Make a test print on paper before you print on the film.
Allow the film to cool after printing so that the ink can dry.
12.Cut the slide-in labels out of the film along the edges.
13.Round off the corners of the slide-in labels approx. 1.5 mm to facilitate insertion.
Machine control panels
Manual, 03/2016, 6FC5397-1AP40-5BA3
77

 

 

 

 

 

 

 