Subaru Impreza 3 / Impreza WRX / Impreza WRX STI. Manual - part 348

 

  Index      Subaru     Subaru Impreza 3 / Impreza WRX / Impreza WRX STI - service repair manual 2008-2014 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  346  347  348  349   ..

 

 

Subaru Impreza 3 / Impreza WRX / Impreza WRX STI. Manual - part 348

 

 

GD(H4DOTC)-144

Diagnostic Trouble Code (DTC) Detecting Criteria

GENERAL DESCRIPTION

Map 3 (Models without SI-DRIVE)

Intake air (g (oz)/rev)

0.1

(0)

0.25

(0.01)

0.3

(0.01)

1

(0.04)

Threshold value (V)

13

13

3.25

3.25

Map 3 (Models with SI-DRIVE)

Intake air (g (oz)/rev)

0.1

(0)

0.25

(0.01)

0.3

(0.01)

1

(0.04)

Threshold value (V)

100

100

4.5

4.5

Map 4

Secondary 
air pressure 
in the pipe 
when both 
comb. valve 
is closing 
kPa 
(mmHg, 
inHg)
Secondary 
air pressure 
in the pipe 
when LH 
comb. valve 
is closing 
kPa 
(mmHg, 
inHg)

69.3

(520, 
20.5)

74.6

(560, 

22)

80

(600, 
23.6)

85.3

(640, 
25.2)

90.6

(680, 
26.8)

96

(720, 
28.3)

101.3

(760, 
29.9)

106.6

(800, 
31.5)

112

(840, 
33.1)

117.3

(880, 
34.6)

122.6

(920, 
36.2)

128

(960, 
37.8)

133.3

(1000, 

39.4)

138.6

(1040, 

40.9)

144

(1080, 

42.5)

149.3

(1120, 

44.1)

69.3
(520, 20.5)

0

200

400

600

800

1000 1200 1400 1600 1800 2000 2200 2400 2400 2400 2400

74.6
(560, 22)

–200

0

200

400

600

800

1000 1200 1400 1600 1800 2000 2200 2400 2400 2400

80
(600, 23.6)

–400 –200

0

200

400

600

800

1000 1200 1400 1600 1800 2000 2200 2400 2400

85.3
(640, 25.2)

–600 –400 –200

0

200

400

600

800

1000 1200 1400 1600 1800 2000 2200 2400

90.6
(680, 26.8)

–800 –600 –400 –200

0

200

400

600

800

1000 1200 1400 1600 1800 2000 2200

96
(720, 28.3)

–1000 –800 –600 –400 –200

0

200

400

600

800

1000 1200 1400 1600 1800 2000

101.3
(760, 29.9)

–1200 –1000 –800 –600 –400 –200

0

200

400

600

800

1000 1200 1400 1600 1800

106.6
(800, 31.5)

–1400 –1200 –1000 –800 –600 –400 –200

0

200

400

600

800

1000 1200 1400 1600

112
(840, 33.1)

–1600 –1400 –1200 –1000 –800 –600 –400 –200

0

200

400

600

800

1000 1200 1400

117.3
(880, 34.6)

–1800 –1600 –1400 –1200 –1000 –800 –600 –400 –200

0

200

400

600

800

1000 1200

122.6
(920, 36.2)

–2000 –1800 –1600 –1400 –1200 –1000 –800 –600 –400 –200

0

200

400

600

800

1000

128
(960, 37.8)

–2200 –2000 –1800 –1600 –1400 –1200 –1000 –800 –600 –400 –200

0

200

400

600

800

133.3
(1000, 39.4)

–2400 –2200 –2000 –1800 –1600 –1400 –1200 –1000 –800 –600 –400 –200

0

200

400

600

138.6
(1040, 40.9)

–2400 –2400 –2200 –2000 –1800 –1600 –1400 –1200 –1000 –800 –600 –400 –200

0

200

400

GD(H4DOTC)-145

Diagnostic Trouble Code (DTC) Detecting Criteria

GENERAL DESCRIPTION

144
(1080, 42.5)

–2400 –2400 –2400 –2200 –2000 –1800 –1600 –1400 –1200 –1000 –800 –600 –400 –200

0

200

149.3
(1120, 44.1)

–2400 –2400 –2400 –2400 –2200 –2000 –1800 –1600 –1400 –1200 –1000 –800 –600 –400 –200

0

(L/min)

Map 4

Secondary 
air pressure 
in the pipe 
when both 
comb. valve 
is closing 
kPa 
(mmHg, 
inHg)
Secondary 
air pressure 
in the pipe 
when LH 
comb. valve 
is closing 
kPa 
(mmHg, 
inHg)

69.3

(520, 
20.5)

74.6

(560, 

22)

80

(600, 
23.6)

85.3

(640, 
25.2)

90.6

(680, 
26.8)

96

(720, 
28.3)

101.3

(760, 
29.9)

106.6

(800, 
31.5)

112

(840, 
33.1)

117.3

(880, 
34.6)

122.6

(920, 
36.2)

128

(960, 
37.8)

133.3

(1000, 

39.4)

138.6

(1040, 

40.9)

144

(1080, 

42.5)

149.3

(1120, 

44.1)

GD(H4DOTC)-146

Diagnostic Trouble Code (DTC) Detecting Criteria

GENERAL DESCRIPTION

Map 5

Secondary 
air pressure 
in the pipe 
when both 
comb. valve 
is closing 
kPa 
(mmHg, 
inHg)
Secondary 
air pressure 
in the pipe 
when RH 
comb. valve 
is closing 
kPa 
(mmHg, 
inHg)

69.3

(520, 
20.5)

74.6

(560, 

22)

80

(600, 
23.6)

85.3

(640, 
25.2)

90.6

(680, 
26.8)

96

(720, 
28.3)

101.3

(760, 
29.9)

106.6

(800, 
31.5)

112

(840, 
33.1)

117.3

(880, 
34.6)

122.6

(920, 
36.2)

128

(960, 
37.8)

133.3

(1000, 

39.4)

138.6

(1040, 

40.9)

144

(1080, 

42.5)

149.3

(1120, 

44.1)

69.3
(520, 20.5)

0

200

400

600

800

1000 1200 1400 1600 1800 2000 2200 2400 2400 2400 2400

74.6
(560, 22)

–200

0

200

400

600

800

1000 1200 1400 1600 1800 2000 2200 2400 2400 2400

80
(600, 23.6)

–400 –200

0

200

400

600

800

1000 1200 1400 1600 1800 2000 2200 2400 2400

85.3
(640, 25.2)

–600 –400 –200

0

200

400

600

800

1000 1200 1400 1600 1800 2000 2200 2400

90.6
(680, 26.8)

–800 –600 –400 –200

0

200

400

600

800

1000 1200 1400 1600 1800 2000 2200

96
(720, 28.3)

–1000 –800 –600 –400 –200

0

200

400

600

800

1000 1200 1400 1600 1800 2000

101.3
(760, 29.9)

–1200 –1000 –800 –600 –400 –200

0

200

400

600

800

1000 1200 1400 1600 1800

106.6
(800, 31.5)

–1400 –1200 –1000 –800 –600 –400 –200

0

200

400

600

800

1000 1200 1400 1600

112
(840, 33.1)

–1600 –1400 –1200 –1000 –800 –600 –400 –200

0

200

400

600

800

1000 1200 1400

117.3
(880, 34.6)

–1800 –1600 –1400 –1200 –1000 –800 –600 –400 –200

0

200

400

600

800

1000 1200

122.6
(920, 36.2)

–2000 –1800 –1600 –1400 –1200 –1000 –800 –600 –400 –200

0

200

400

600

800

1000

128
(960, 37.8)

–2200 –2000 –1800 –1600 –1400 –1200 –1000 –800 –600 –400 –200

0

200

400

600

800

133.3
(1000, 39.4)

–2400 –2200 –2000 –1800 –1600 –1400 –1200 –1000 –800 –600 –400 –200

0

200

400

600

138.6
(1040, 40.9)

–2400 –2400 –2200 –2000 –1800 –1600 –1400 –1200 –1000 –800 –600 –400 –200

0

200

400

144
(1080, 42.5)

–2400 –2400 –2400 –2200 –2000 –1800 –1600 –1400 –1200 –1000 –800 –600 –400 –200

0

200

149.3
(1120, 44.1)

–2400 –2400 –2400 –2400 –2200 –2000 –1800 –1600 –1400 –1200 –1000 –800 –600 –400 –200

0

(L/min)

GD(H4DOTC)-147

Diagnostic Trouble Code (DTC) Detecting Criteria

GENERAL DESCRIPTION

CI: DTC P0411 SECONDARY AIR INJECTION SYSTEM INCORRECT FLOW DE-

TECTED

1. OUTLINE OF DIAGNOSIS

NOTE:

For the detection standard, refer to DTC P0410. <Ref. to GD(H4DOTC)-139, DTC P0410 SECONDARY AIR

INJECTION SYSTEM, Diagnostic Trouble Code (DTC) Detecting Criteria.>

Map 6

Amount of intake air when RH comb. valve switches (g (oz)/s)
Battery voltage when RH comb. valve switches (V)

10

(0.35)

15

(0.53)

20

(0.71)

25

(0.88)

26

(0.92)

11

0.025

0.025

0.025

0.005

0

12

0.035

0.035

0.035

0.015

0

13

0.05

0.05

0.05

0.025

0

14

0.05

0.05

0.05

0.025

0

(V)

Map 7

Amount of intake air when LH comb. valve switches (g (oz)/s)
Battery voltage when LH comb. valve switches (V)

10

(0.35)

15

(0.53)

20

(0.71)

25

(0.88)

26

(0.92)

11

0.025

0.025

0.025

0.005

0

12

0.035

0.035

0.035

0.015

0

13

0.05

0.05

0.05

0.025

0

14

0.05

0.05

0.05

0.025

0

(V)

Map 8

Amount of intake air when P0R is measuring (g (oz)/s)
Battery voltage when P0R measuring (V)

2

(0.07)

25

(0.88)

11.5

345

345

12.5

345

345

13.5

345

345

14.5

390

390

15.5

420

420

(L/min)

Map 9

Amount of intake air when P0L is measuring (g (oz)/s)
Battery voltage when P0L measuring (V)

2

(0.07)

25

(0.88)

11.5

345

345

12.5

345

345

13.5

345

345

14.5

390

390

15.5

420

420

(L/min)

 

 

 

 

 

 

 

Content   ..  346  347  348  349   ..