HAZARD SWITCH EXL-249 < DTC/CIRCUIT DIAGNOSIS > [HALOGEN HEADLAMP] C D E F G H I J K M A B EXL N O P HAZARD SWITCH Component Function Check INFOID:0000000010121468 1. CHECK HAZARD SWITCH SIGNAL BY CONSULT CONSULT DATA MONITOR 1. Turn power switch ON. 2. Select “HAZARD SW” in “Data Monitor” of “BCM (FLASHER)”. 3. While operating the hazard switch, check the monitor status. Is the inspection result normal? YES >> Hazard switch circuit is normal. NO >> Refer to EXL-249, "Diagnosis Procedure" . Diagnosis Procedure INFOID:0000000010121469 Regarding Wiring Diagram information. Refer to 1. CHECK HAZARD SWITCH SIGNAL INPUT 1. Turn power switch OFF. 2. Disconnect hazard switch connector. 3. Check voltage between hazard switch connector and ground. Is the inspection result normal? YES >> GO TO 4. NO >> GO TO 2. 2. CHECK HAZARD SWITCH SIGNAL OPEN CIRCUIT 1. Disconnect BCM connector. 2. Check continuity between hazard switch harness connector and BCM harness connector. Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace harness. 3. CHECK HAZARD SWITCH SIGNAL SHORT CIRCUIT Check continuity between hazard switch harness connector and ground. Monitor item Condition Monitor status HAZARD SW Hazard switch ON On OFF Off (+) ( −) Voltage (Approx.) Hazard switch Connector Terminal M45 2 Ground Battery voltage Hazard switch BCM Continuity Connector Terminal Connector Terminal M45 2 M24 29 Yes Hazard switch Ground Continuity Connector Terminal M45 2 No |