EXL-128 < DTC/CIRCUIT DIAGNOSIS > HAZARD SWITCH 3. CHECK HAZARD SWITCH SIGNAL SHORT CIRCUIT Check continuity between hazard switch harness connector and ground. Is the inspection result normal? YES >> Replace BCM. Refer to BCS-80, "Removal and Installation" NO >> Repair or replace the harness or connector. 4. CHECK HAZARD SWITCH GROUND OPEN CIRCUIT Check continuity between hazard switch harness connector and ground. Is the inspection result normal? YES >> Replace hazard switch. Refer to EXL-148, "Removal and Installation" NO >> Repair or replace the harness or connectors. Hazard switch Ground Continuity Connector Terminal M26 2 No Hazard switch Ground Continuity Connector Terminal M26 3 Yes |