KEYLESS ENTRY AND BURGLAR ALARM

BE -45

CONDITION 5

State

Description

Initial Condition

AUTOLOCK TIMER2 state

Transition Condition

-

When any one of the 4DOOR, HOOD or T/GATE is opened.

-

In case of KEY IN.

-

LOCK FAIL after the LOCK attempt by the AUTO LOCK.

-

LOCK FAIL after the LOCK attempt by the TX LOCK.

-

LOCK FAIL after the LOCK attempt by the DRIVER KEY LOCK
(In case of B_MECH_KEY=Enable)

Operating

-

ENTRY INTO THE DISARM STATE

CONDITION 6

State

Description

Initial Condition

ARM state

Transition Condition

-

IGN KEY ON

-

DRIVER KEY UNLOCK(T/GATE KEY UNLOCK) input.

Operating

-

ENTRY INTO THE DISARM STATE

CONDITION 7

State

Description

Initial Condition

REARM state

Transition Condition

-

After 30 seconds in the IGN KEY ON state.

-

LOCK FAIL after the LOCK attempt by the TX LOCK.

-

LOCK FAIL after the LOCK attempt by the DRIVER KEY LOCK.

-

When entering DRIVER KEY UNLOCK.

Operating

-

ENTRY INTO THE DISARM STATE

-

B/ALARM RELAY OFF

CONDITION 8

State

Description

Initial Condition

REARM state

Transition Condition

-

In case of TX UNLOCK INPUT in the state that any one of the
4DOOR or T/GATE is opened.

-

In case of KEY IN.

-

In case of the 4DOORor T/GATE or HOOD is closed and at least one door is unlocked.

Operating

-

ENTRY INTO THE DISARM STATE

-

In the case of the TX UNLOCK INPUT, the HAZARD LAMP signal is output
two times with the ON/OFF cycle of 0.5 seconds.

BE -46

BODY ELECTRICAL SYSTEM

3.

ARM

CONDITION 1

State

Description

Initial Condition

ARM state

Transition Condition

When entering TX LOCK

Operating

-

Keep the ARM state

-

The HAZARD LAMP signal is output for 1s once.

CONDITION 2

State

Description

Initial Condition

ARM WAIT state

Transition Condition

After the ARM WAIT TIMER completion

Operating

-

ENTRY INTO THE ARM state

4.

ALARM

CONDITION 1

State

Description

Initial Condition

ARM state

Transition Condition

In case of 4DOOR, T/GATE or HOOD is opened.

Operating

-

ENTRY INTO THE ALARM state

-

The B/ALARM RELAY outputs is ON, and then, inhibit the start.

-

Non-EC area: the Horn alarm shall be output three times with the cycle consisting
of the ON for 27s(±2s) and the OFF for 10s(±1s). (At this time, the Hazard
Lamp signal shall also be output as the Horn alarm.)

-

EC and The Middle EAST: the HORN alarm output shall be ON for 27s(±2s) once. (At
this time, the Hazard Lamp signal output shall also be ON as the Horn alarm.)

CONDITION 2

State

Description

Initial Condition

REARM state

Transition Condition

In case of 4DOOR, T/GATE or HOOD is opened.

Operating

-

ENTRY INTO THE ALARM state

-

Non-EC area: the Horn alarm shall be output three times with the cycle
consisting of the ON for 27s(±2s) and the OFF for 10s(±1s). (At this time, the
Hazard Lamp signal shall also be output as the Horn alarm.)

-

EC and The Middle EAST: the HORN alarm output shall be ON for 27s(±2s) once.
(At this time, the Hazard Lamp signal output shall also be ON as the Horn alarm.)

KEYLESS ENTRY AND BURGLAR ALARM

BE -47

ARM
STATE

ARM/
REARM
DISARM

4DOOR
HOOD
T/GATE

OPEN

CLOSE

B/ALARM
RELAY

ON

OFF

ON

B/HORN
RELAY

OFF

HAZARD
RELAY

ON

OFF

T2

T1

T1

T1

T3

T3

Non-EC SPECIFICATION

SCMBE6124L

T1 : 27 ± 2sec, T2 : 0.4 ~ 0.5 sec,
T3 : 10 ± 1sec.

ARM
STATE

ARM/
REARM
DISARM

4DOOR
HOOD
T/GATE

OPEN

CLOSE

B/ALARM
RELAY

ON

OFF

ON

B/HORN
RELAY

OFF

HAZARD
RELAY

ON

OFF

T2

T1

EC SPECIFICATION

SCMBE6119L

T1 : 27 ± 2sec, T2 : 0.4 ~ 0.5 sec.

5.

ARM WAIT

CONDITION 1

State

Description

Initial Condition

ARM WAIT state

Transition Condition

When entering TX LOCK

Operating

-

Keep ARM WAIT state

-

The HAZARD LAMP signal shall be output for 1s once.

CONDITION 2

State

Description

Initial Condition

DISARM state & IGN KEY OUT & 4DOOR, T/GATE and HOOD CLOSE state

Transition Condition

-

In case of LOCK SUCCESS after the LOCK attempt by the TX LOCK.

-

In case of LOCK SUCCESS after the LOCK attempt by the DRIVER
KEY LOCK (T/GATE KEY LOCK) INPUT.

-

In case of 4DOOR, T/GATE, HOOD OPEN>CLOSE with all doors locked.

Operating

-

Entry into the ARM WAIT state

-

The HAZARD LAMP signal shall be output for 1s once.

-

Start the ARMWAIT TIMER

CONDITION 3

State

Description

Initial Condition

ALARM state & IGN KEY OUT & 4DOOR, T/GATE and HOOD CLOSE state

Transition Condition

-

In case of LOCK SUCCESS after the LOCK attempt by the TX LOCK.

-

In case of LOCK SUCCESS after the LOCK attempt by the DRIVER
KEY LOCK (T/GATE KEY LOCK) INPUT.

Operating

-

Entry into the ARM WAIT state

-

OFF the HORN, B/ALARM output.

-

The HAZARD LAMP signal shall be output for 1s once

-

Start the ARMWAIT TIMER

BE -48

BODY ELECTRICAL SYSTEM

CONDITION 4

State

Description

Initial Condition

AUTOLOCK TIMER1 state

Transition Condition

-

In case of LOCK SUCCESS after the LOCK attempt by the AUTOLOCK.

-

In case of LOCK SUCCESS after the LOCK attempt by the TX LOCK.

-

In case of LOCK SUCCESS after the LOCK attempt by the DRIVER
KEY LOCK (T/GATE KEY LOCK) INPUT

Operating

-

Entry into the ARM WAIT state

-

The HAZARD LAMP signal shall be output for 1s once.

-

Start the ARMWAIT TIMER

CONDITION 5

State

Description

Initial Condition

PREARM state

Transition Condition

-

4DOOR, T/GATE and HOOD are closed and all doors are locked.

Operating

-

Entry into the ARM WAIT state

-

The HAZARD LAMP signal shall be output for 1s once.

-

Start the ARMWAIT TIMER

CONDITION 6

State

Description

Initial Condition

REARM state

Transition Condition

-

LOCK SUCCESS after the LOCK attempt by the TX LOCK.

-

LOCK SUCCESS after the LOCK attempt by the DRIVER KEY LOCK
(T/GATE KEY LOCK) INPUT.

Operating

-

Entry into the ARM WAIT state

-

The HAZARD LAMP signal shall be output for 1s once.

-

B/ALARM RLY OFF

-

Start the ARMWAIT TIMER

6.

REARM

CONDITION 1

State

Description

Initial Condition

ALARM state

Transition Condition

4DOOR, T/GATE and HOOD are closed and after the ALARM PATTERN completion

Operating

-

Entry into the REARM state

 

 

 

 

 

 

 