Hyundai Santa Fe (2006 year). Manual - part 147

 

  Index      Hyundai     Hyundai Santa Fe - service repair manual 2006 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  145  146  147  148   ..

 

 

Hyundai Santa Fe (2006 year). Manual - part 147

 

 

KEYLESS ENTRY AND BURGLAR ALARM

BE -49

7.

AUTO-LOCK TIMER1

CONDITION 1

State

Description

Initial Condition

ARM state

Transition Condition

TX UNLOCK INPUT

Operating

-

Entry into the AUTO-LOCK TIMER1 state

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START the AUTOLOCK TIMER1

CONDITION 2

State

Description

Initial Condition

REARM state

Transition Condition

-

AUTO-LOCK TIMER1 state.

-

TX UNLOCK INPUT.

Operating

-

keep the AUTO-LOCK TIMER1 state

-

CASE1: AUTOLOCK TIMER1 COMPLETION LOCK ATTEMPT.

-

CASE2: TX UNLOCK

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times

-

RESTART THE AUTOLOCK TIMER1

CONDITION 3

State

Description

Initial Condition

ARM WAIT state

Transition Condition

TX UNLOCK INPUT

Operating

-

Entry into the AUTO-LOCK TIMER1 state

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START THE AUTOLOCK TIMER

CONDITION 4

State

Description

Initial Condition

The DISARM state and 4DOOR, T/GATE and HOOD are closed and IGN KEY OUT

Transition Condition

TX UNLOCK INPUT

Operating

-

Entry into the AUTO-LOCK TIMER1 STATE

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START THE AUTOLOCK TIMER1

CONDITION 5

State

Description

Initial Condition

ALARM state, and 4DOOR, T/GATE and HOOD CLOSE state

Transition Condition

TX UNLOCK INPUT

Operating

-

Entry into the AUTO-LOCK TIMER1 STATE

-

B/ALARM RELAY OFF

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START THE AUTOLOCK TIMER1

BE -50

BODY ELECTRICAL SYSTEM

CONDITION 6

State

Description

Initial Condition

REARM state

Transition Condition

TX UNLOCK INPUT

Operating

-

Entry into the AUTO-LOCK TIMER1 STATE

-

B/ALARM RELAY OFF

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START THE AUTOLOCK TIMER1

8.

AUTO-LOCK TIMER 2

CONDITION 1

State

Description

Initial Condition

AUTO-LOCK TIMER2 state

Transition Condition

-

AUTOLOCK TIMER2 COMPLETION.

-

TX UNLOCK INPUT.

Operating

-

keep the AUTO-LOCK TIMER2 state

-

CASE1: AUTOLOCK TIMER1 COMPLETION LOCK ATTEMPT.

-

CASE2: TX UNLOCK

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times

-

RESTART THE AUTOLOCK TIMER1

CONDITION 2

State

Description

Initial Condition

REARM state

Transition Condition

DISARM state AND 4DOOR & T/GATE CLOSE & HOOD OPEN AND IGN KEY OUT

Operating

-

Entry into the AUTO-LOCK TIMER2 STATE

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START THE AUTOLOCK TIMER2

CONDITION 3

State

Description

Initial Condition

ALARM STATE AND 4DOOR & T/GATE CLOSE & HOOD OPEN STATE

Transition Condition

TX UNLOCK INPUT

Operating

-

Entry into the AUTO-LOCK TIMER2 STATE

-

OFF the HORN, B/ALARM OUTPUT

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START THE AUTOLOCK TIMER2

KEYLESS ENTRY AND BURGLAR ALARM

BE -51

CONDITION 4

State

Description

Initial Condition

PREARM START AND 4DOOR & T/GATE CLOSE & HOOD OPEN STATE

Transition Condition

TX UNLOCK INPUT

Operating

-

Entry into the AUTO-LOCK TIMER2 STATE

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START THE AUTOLOCK TIMER2

9.

PREARM

CONDITION 1

State

Description

Initial Condition

AUTO-LOCK TIMER2 state

Transition Condition

-

LOCK SUCCESS after the LOCK attempt by the AUTO LOCK.

-

LOCK SUCCESS after the LOCK attempt by the TX LOCK.

-

LOCK SUCCESS after the LOCK attempt by the DRIVER KEY
LOCK (T/GATE KEY LOCK) INPUT.

Operating

-

Entry into the PREARM state

CONDITION 2

State

Description

Initial Condition

DISARM state & IGN KEY OUT

Transition Condition

-

LOCK SUCCESS after the LOCK ATTEMPT by the TX LOCK in the state
that 4 DOOR or T/GATE or HOOD is opened.

-

LOCK SUCCESS after the LOCK ATTEMPT by the DRIVER KEY LOCK (T/GATE
KEY LOCK) INPUT in the state that 4 DOOR or T/GATE or HOOD is opened.

-

The DOOR is turned to the CLOSE state from the OPEN state in the state
that all doors are locked. But, the HOOD is opened.

Operating

-

Entry into the PREARM state

CONDITION 3

State

Description

Initial Condition

ALARM state & IGN KEY OUT & 4DOOR or T/GATE or HOOD OPEN

Transition Condition

-

LOCK SUCCESS after the LOCK attempt by the TX LOCK.

-

LOCK SUCCESS after the LOCK attempt by the DRIVER KEY
LOCK (T/GATE KEY LOCK) INPUT.

Operating

-

Entry into the PREARM state

-

OFF the HORN, HAZARD, B/ALARM OUTPUT

BE -52

BODY ELECTRICAL SYSTEM

10. RESET

CONDITION 1

State

Description

Initial Condition

ALARM, REARM state

Transition Condition

Insert after the BATTERY is withdrawn

Operating

-

The B/ALARM RELAY shall be ON and the HORN ALARM shall be
output three times again (EC SPEC ONCE).

CONDITION 2

State

Description

Initial Condition

ARM state

Transition Condition

Insert after the BATTERY is withdrawn

Operating

-

Keep the ARM state.

 

 

 

 

 

 

 

Content   ..  145  146  147  148   ..