FANUC Series 30i/300i/300is-MODEL A. Machining Center System. User's manual - page 253

 

  Index      Manuals     FANUC Series 30i/300i/300is-MODEL A. Machining Center System. User's manual (B-63944EN/03)

 

Search            copyright infringement  

 

 

 

 

 

 

 

 

 

 

 

Content      ..     251      252      253      254     ..

 

 

 

FANUC Series 30i/300i/300is-MODEL A. Machining Center System. User's manual - page 253

 

 

1.ROUTINE MAINTENANCE

 MAINTENANCE 

B-63944EN/03

 

 

- 1980 - 

 

 CAUTION 

1  The connector of the battery can be connected with 

either of CX5X and CX5Y. 

2  Attaching the battery from the cable outlet applies 

tension to the cable.    Therefore, attach the cable 
from another place to prevent the cable from being 
stretched.    If this cable is connected on a stretch 
condition, a bad conductivity may be occurred. 

 

 - Used batteries 

Old batteries should be disposed as "INDUSTRIAL WASTES" 
according to the regulations of the country or autonomy where your 
machine has been installed. 
 
 

 

 

 
 
 
 
 
 
 
 
 

APPENDIX 

 

B-63944EN/03

 APPENDIX 

A.PARAMETERS

 

 

- 1983 - 

PARAMETERS 

 
This manual describes all parameters indicated in this manual. 
For those parameters that are not indicated in this manual and other 
parameters, refer to the parameter manual. 
 

NOTE 

 

A parameter that is valid with only one of the path 
control types for the lathe system (T series) and 
machining center system (M series) is indicated in 
the upper or lower row as described below.    A blank 
represents an unusable parameter. 

 
[Example 1] 
 

The parameter HTG is common to the T series and 
M series, and RTV and ROC are parameters used 
with the T series only. 

 

 

1403

RTV

ROC

HTG

HTG

T series

M series

#7

#6

#5

#4

#3

#2

 

#1

 

#0

 
[Example 2] 
 

The following parameter is used with the M series 
only: 

 

 

1411

Cutting feedrate

T series

M series

 

 

A.PARAMETERS

 APPENDIX 

B-63944EN/03

 

 

- 1984 - 

A.1 

DESCRIPTION OF PARAMETERS 

 

  

#7 #6 #5 #4 #3 #2 #1 #0 

0000 

 

      

ISO 

TVC 

 

 

[Input type]  Setting input 

 

[Data type]  Bit path 

 

        # 0 

TVC

 TV 

check 

0: Not 

performed 

1: Performed 
 

        # 1 

ISO

  Code used for data output 

0: EIA 

code 

1: ISO 

code 

 

NOTE 

 

ASCII code is used at all times for output to the 
memory card. 

 

  

#7 #6 #5 #4 #3 #2 #1 #0 

0001 

 

      

FCV 

 

 

 

[Input type]  Setting input 

 

[Data type]  Bit path 

 

        # 1 

FCV

 Program 

format 

0:  Series 16 standard format 
1:  Series 15 format 
 

NOTE 

1  Programs created in the Series 15 program format 

can be used for operation on the following 
functions: 

1  Subprogram call M98 
2  Thread cutting with equal leads G32 (T series) 
3  Canned cycle G90, G92, G94 (T series) 
4  Multiple repetitive canned cycle G71 to G76 (T 

series) 

5  Drilling canned cycle 

G83.1, G80 to G89 (T series) 
G73, G74, G76, G80 to G89(M series) 

2  When the program format used in the Series 15 is 

used for this CNC, some limits may add. Refer to 
the User’s Manual. 

 

B-63944EN/03

 APPENDIX 

A.PARAMETERS

 

 

- 1985 - 

  

#7 #6 #5 #4 #3 #2 #1 #0 

0010 

 

      

PRM 

 

 

 

[Input type]  Setting input 

 

[Data type]  Bit path 

 

        # 1 

PRM

  When parameters are output, the parameters whose values are 0 are: 

0: Output. 
1: Not 

output. 

 

  

#7 #6 #5 #4 #3 #2 #1 #0 

0012 

 

       

MIRx

 

 

[Input type]  Setting input 

 

[Data type]  Bit axis 

 

        # 0 

MIRx

  Mirror image for each axis 

0:  Mirror image is off. (Normal) 
1:  Mirror image is on. (Mirror) 
 

0020 

 

I/O CHANNEL : Input/output device selection, or interface number for a 

foreground input device 

 

 

[Input type]  Setting input 

 [Data 

type] 

Byte 

  [Valid data range]  0 to 5 

The CNC has the following interfaces for transferring data to and from 
an external input/output device and the host computer: 
 

Input/output device interface (RS-232-C serial ports 1 and 2) 

 

Memory card interface 

 

Data server interface 

 

Embedded Ethernet interface 

By setting bit 0 (IO4) of parameter No. 0110, data input/output can be 
controlled separately. When IO4 is not set, data input/output is 
performed using the channel set in parameter No. 0020. When IO4 is 
set, a channel can be assigned to each of foreground input, foreground 
output, background input, and background output. 
In these parameters, specify the interface connected to each 
input/output device to and from which data is to be transferred. See 
the table below for these settings. 

 

Correspondence between settings and input/output devices 

Setting Description 

0,1 

RS-232-C serial port 1 

RS-232-C serial port 2 

Memory card interface 

Data server interface 

Embedded Ethernet interface 

 

A.PARAMETERS

 APPENDIX 

B-63944EN/03

 

 

- 1986 - 

  

#7 #6 #5 #4 #3 #2 #1 #0 

0100 

 

    

NCR 

 

CTV 

 

 

 

[Input type]  Setting input 

 [Data 

type] 

Bit 
 

        # 1 

CTV

  Character counting for TV check in the comment section of a 

program. 
0: Performed 
1: Not 

performed 

 

        # 3 

NCR

  Output of the end of block (EOB) in ISO code 

0:  LF, CR, CR are output. 
1:  Only LF is output. 
 

  

#7 #6 #5 #4 #3 #2 #1 #0 

0138 

 

MNC 

       

 

 

[Input type]  Parameter input 

 [Data 

type] 

Bit 
 

        # 7 

MNC

  DNC operation from the memory card and external device 

subprogram call from the memory card are: 
0: Not 

performed. 

1: Performed. 
 

0983 

 

Path control type of each path 

 

NOTE 

 

When this parameter is set, the power must be 
turned off before operation is continued. 

 

 

[Input type]  Parameter input 

 

[Data type]  Byte path 

  [Valid data range]  0 to 1 

Set the path control type of each path. 
The following two path control types are available: 
T series (lathe system) 

:  0 

M series (machining system)  :  1 
 

B-63944EN/03

 APPENDIX 

A.PARAMETERS

 

 

- 1987 - 

  

#7 #6 #5 #4 #3 #2 #1 #0 

0984 

 

       

LCP 

 

 

[Input type]  Parameter input 

 

[Data type]  Bit path 

 

NOTE 

 

When this parameter is set, the power must be 
turned off before operation is continued. 

 

        # 0 

LCP

  Set whether the path is a loader control path. 

0:  The path is not a loader control path.   
1:  The path is a loader control path. 
 

  

#7 #6 #5 #4 #3 #2 #1 #0 

1001 

 

       

INM 

 

 

[Input type]  Parameter input 

 

[Data type]  Bit path 

 

NOTE 

 

When this parameter is set, the power must be 
turned off before operation is continued. 

 

        # 0 

INM

  Least command increment on the linear axis 

0:  In mm (metric system machine) 
1:  In inches (inch system machine) 
 

  

#7 #6 #5 #4 #3 #2 #1 #0 

1002 

 

IDG 

  

XIK 

AZR 

  

JAX 

 

 

[Input type]  Parameter input 

 

[Data type]  Bit path 

 

    # 0 

JAX

  Number of axes controlled simultaneously in jog feed, manual rapid 

traverse and manual reference position return 
0: 1 

axis 

1: 3 

axes 

 

 

 

 

 

 

 

 

Content      ..     251      252      253      254     ..