1. AXIS CONTROL
B-64693EN-1/01
- 138 - NOTE 1 In addition, it is necessary to set FSSB. Refer to Parameter Nos.24000 to 24095 for details. 2 If value of this parameter is larger than the maximum value, the alarm SP1996, "ILLEGAL SPINDLE PARAMETER SETTING" occurs. 3 If the spindle motor is treated as hypothetical Cs axis control or spindle control with servo motor, set this parameter to “0”. 4 In the display order of the parameter No.982, the spindle axes since the spindle axis that 0 is set to this parameter become invalid, too. However, the case that the spindle motor is treated as hypothetical Cs axis control or spindle control with servo motor is excepted. Example) On the following setting, S3 and S4 spindle axes are invalid when the spindle motor of S3 is not treated as hypothetical Cs axis control or spindle control with servo motor. Display order of No.982 Setting value of No.982 Setting value of No.3717 S1 1 1 S2 2 2 S3 1 0 S4 2 3
#7 #6 #5 #4 #3 #2 #1 #0 14476
SSC
[Input type] Parameter input
[Data type] Bit
NOTE When this parameter is set, the power must be turned off before operation is continued.
#5 SSC The number of ATR values for a separate detector interface unit connector is: 0: Only 1. 1: More than 1.
NOTE When this parameter is set to 1, FSSB automatic setting cannot be performed.
24000
ATR value corresponding to slave 01 on first FSSB line
24001
ATR value corresponding to slave 02 on first FSSB line to
to 24031
ATR value corresponding to slave 32 on first FSSB line
|