FANUC Series 0i-MODEL F Plus. CONNECTION MANUAL (FUNCTION) - page 18

 

  Index      Manuals     FANUC Series 0i-MODEL F Plus. CONNECTION MANUAL (FUNCTION) B-64693EN-1/01

 

Search            copyright infringement  

 

 

 

 

 

 

 

 

 

 

 

Content      ..     16      17      18      19     ..

 

 

 

FANUC Series 0i-MODEL F Plus. CONNECTION MANUAL (FUNCTION) - page 18

 

 

1. AXIS CONTROL

 

 

B-64693EN-1/01

 

- 98 - 

 

- When 

a

A1000S sensors which is separate pulsecoder is used as a separate detector. 

 

- A scale without rotary data 

 

For the following detectors, these are "a scale without rotary data".   

The following detectors are not all of the detector which is "a scale without rotary data". 

 

HEIDENHAIN 

 

 

RCN223F / RCN727F 

 

Magnescale 

 

 

RU77 

 

MITSUBISHI HEAVY INDUSTRIES 

 

 

MPRZ Series   

 

RENISHAW 

 

 

RESOLUTE (rotary encoder) 

 

NOTE 

  Please make sure to confirm the using detector to the detector manufacturers. 

 

  -  Coordinate systems at power-on 

(1)  The machine and workpiece coordinate systems are automatically set. When bit 3 (PPD) of 

parameter No. 3104 is set to 1, the relative position display is preset. When parameter PPD is set to 0, 

it is also possible to preset relative coordinates with machine coordinates by setting bit 5 (PWR) of 

parameter No. 11277 to 1. 

(2)  The amount of shift by coordinate system setting (G92 for the M series or G50 for the T series) or 

local coordinate system setting (G52) is cleared. 

 

  -  Setting the zero point of an absolute position detector 

In the following cases, set the zero point of an absolute position detector (bring the counter value of the 

absolute position detector into correspondence with the reference position): 

 

Primary adjustment is performed (after the reference position is determined). 

 

The reference position is changed. 

 

An absolute position detector is replaced with another. 

 

A servo motor is replaced with another. 

 

Alarm DS0300 is issued. 

 

The file memory is replaced with another. 

 

Parameter data is cleared. 

To set the zero point of an absolute position detector, the following two methods are available: One 

method using manual reference position return and the other using MDI operation. 

 

  -  Manual reference position return 

Follow the procedure below to perform manual reference position return. 

(1)  Set bit 4 (APZ) of parameter No. 1815 to 0. Alarms PW0000 and DS0300 are displayed. 

(2)  Turn the power off, then on again. Alarm DS0300 is displayed. 

(3)  Perform manual reference position return. When manual reference position return is completed, bit 4 

(APZ) of parameter No. 1815 is automatically set to 1. 

(4)  Press the reset button to release alarm DS0300. 

Operation in step (3) can also be performed by reference position setting without DOG, reference point 

setting with mechanical stopper, or reference point setting with mechanical stopper by grid method. 

 

  -  Setting the zero point using MDI operation 

Follow the procedure below to set the zero point using MDI operation. 

(1)  Set bit 4 (APZ) of parameter No. 1815 to 0. Alarms PW0000 and DS0300 are displayed. 

(2)  Turn the power off, then on again. Alarm DS0300 is displayed. 

(3)  Move the tool to the reference position in jog, manual handle, or manual incremental feed. 

(4)  Set bit 4 (APZ) of parameter No. 1815 to 1. Alarm PW0000 is displayed. 

B-64693EN-1/01

 

 

1. AXIS CONTROL

 

- 99 - 

(5)  Turn the power off, then on again. 

 

  CAUTION 

  If setting the zero point using MDI operation causes the reference position to be 

lost for some reason, any FANUC service personnel and end user cannot restore 

the reference position accurately. In this case, you should ask the machine tool 

builder to restore the accurate reference position, which requires an immense 

amount of time for restoration. So, do not use MDI operation to set the zero point. 

For details, see “Reexecuting zero point setting” described later. 

 

  -  Voltage of backup batteries 

Normally, the voltage of the backup batteries for the absolute position detector is 6 V. The voltage drops 

as time goes on. 

 

6V 

Signal 

PBATL 

Signal 

PBATZ 

4.5V

 

1.5V

 

 

 

When the voltage of the backup batteries becomes 4.5 V or less 

 

When the voltage of the backup batteries becomes 4.5 V or less, “APC” is highlighted and blinks in 

the state display area on the screen, and absolute position detector battery voltage low alarm signal 

PBATL <Fn172.7> is set to “1”. 

 

When the power to the CNC is turned off, then on again without replacing the backup batteries and 

the counter value data of the absolute position detector is retained, alarm DS0307, “APC ALARM: 

BATTERY LOW 1” is displayed. Signal PBATL remains set to “1”. 

  In this status, when emergency stop is canceled or the reset key is pressed, alarm DS0307 is released, 

but “APC” is highlighted and blinks in the state display area on the screen. Signal PBATL remains 

set to “1”. 

 

When the batteries are replaced with ones the voltage of which is higher than or equal to the rating 

and the reset key is pressed, “APC” in the status display area on the screen goes out and signal 

PBATL is set to “0”. 

 

  CAUTION 

  If a battery voltage low alarm is displayed, replace the batteries with new ones 

immediately. If the batteries are not replaced, the counter value data of the 

absolute position detector is lost. 

 

When the voltage of the backup batteries becomes 1.5 V or less 

 

When the voltage of the backup batteries is 1.5 V or less, if the power to the CNC is turned off, the 

battery voltage is assumed to be 0, and the counter value data of the absolute position detector is lost. 

When the power to the CNC is turned on again, alarm DS0300, “APC ALARM: NEED REF 

RETURN” and alarm DS0306, “APC ALARM: BATTERY VOLTAGE 0” are displayed, and 

absolute position detector battery voltage zero alarm signal PBATZ <Fn172.6> is set to “1”. 

At this time, bit 4 (APZ) of parameter No. 1815, which indicates that the correspondence between 

the machine position and the position on the absolute position detector is established, is set to 0. 

1. AXIS CONTROL

 

 

B-64693EN-1/01

 

- 100 - 

 

In this status, when emergency stop is canceled or the reset key is pressed, only alarm DS0306 is 

released. Signal PBATZ remains set to “1”. 

 

Follow the procedure below to set the zero point of the absolute position detector. 

  1  Replace the batteries with ones the voltage of which is higher than or equal to the rating. 

  2  Rotate the motor manually at least one turn. 

  3  Turn the power to the CNC and servo amplifier off. 

  4  Turn the power to the CNC and servo amplifier on. 

  5  Set the zero point of the absolute position detector. After that, press the reset key to release 

alarm DS0300. 

 

When the power to the CNC is turned off, then on again after the batteries are replaced with ones the 

voltage of which is higher than or equal to the rating, signal PBATZ is set to “0”. 

 

  -  Reexecuting zero point setting 

If any of the following states occurs after the zero point of an absolute position detector is  set, the 

reference position is lost, which requires the reexecution of zero point setting: 

 

An event occurred, which set any bit of diagnosis data Nos. 310 and 311 to 1. (For example, the 

voltage of the backup batteries became 1.5 V or less, or a parameter was updated, which caused the 

reference position to be lost.) 

 

A failure occurred in the pulse coder or motor, and it was replaced. 

 

In this case, if the zero point is set using MDI operation, any FANUC service personnel and end user 

cannot restore the reference position accurately, and you should ask the machine tool builder to restore 

the accurate reference position, which requires an immense amount of time for restoration. So, do not use 

MDI operation to set the zero point. The following table lists other methods for setting the zero point to 

restore the reference position. 

 

Table 1.4.2 (a)  Reference position restoration 

Zero point 

setting method 

Overview 

Advantages 

Disadvantages 

Manual reference 
position return 

Uses the grid position 
created by the detector and a 
deceleration dog to establish 
the reference position. 

Enables the reference position 
to be restored most reliably. 

Requires a deceleration 
dog. 

Reference 
position setting 
without DOG 

Uses the grid position 
created by the detector and 
starts reference position 
return operation near the 
reference position to 
establish the reference 
position without dogs. 

-  Requires no deceleration 

dog. 

-  Allows the reference 

position to be restored 
easily when the position at 
which to start restoring the 
reference position is clear. 

Cannot restore the 
reference position if the 
position at which to start 
restoring the reference 
position is not clear. 

Reference point 
setting with 
mechanical 
stopper 

Butts the tool against the 
mechanical stopper along an 
axis and makes the tool 
withdraw a set distance from 
the mechanical stopper to 
establish the reference 
position. 

-  Requires no deceleration 

dog. 

-  Allows the reference 

position to be restored very 
easily. 

Lacks the positional 
accuracy of the reference 
position when the following 
factors are taken into 
account: Deformation of the 
part where the tool is 
butted, foreign matters 
attached to the part, etc. 

B-64693EN-1/01

 

 

1. AXIS CONTROL

 

- 101 - 

Zero point 

setting method 

Overview 

Advantages 

Disadvantages 

Reference point 
setting with 
mechanical 
stopper by grid 
method 

Butts the tool against the 
mechanical stopper along an 
axis and makes the tool 
withdraw to the grid position 
created by the detector to 
establish the reference 
position. 

-  Requires no deceleration 

dog. 

-  Allows the reference 

position to be restored very 
easily. 

-  Enables the accurate 

reference position to be 
established since the grid 
position is used. 

 

 

  CAUTION 

1  Do not use MDI operation to set the zero point. It is impossible to restore the 

reference position accurately using this method. 

2  Use manual reference position return using a grid whenever possible. 

3  To use reference position setting without DOG, be sure to place the eye mark 

indicating the start position of reference position return at a position where it can 

be seen without removing the cover and other parts of the machine and make the 

mark last after long-time machine operation. 

4  To use reference point setting with mechanical stopper with using no grid, design 

the machine so that the part where the tool is butted is not deformed and is free 

from chips and other foreign matters. 

5  Be sure to attach a manual which details the method for reference position return 

along each axis to the machine. 

 

  -  Rotary axis A type 

When the increment system (bit 0 to 1 (ISA or ISC) of parameter No. 1013) is changed for an axis in the 

following status, bit 4 (APZ) of parameter No. 1815 is set to 0 to set the status of the correspondence 

between the machine position and the position on the absolute position detector to unestablished: 

 

The zero point is established using the absolute position detector. (Bits 4 (APC) and 5 (APZ) of 

parameter No. 1815 = 1) 

 

Rotary axis A type (Bit 0 (ROT) of parameter No. 1006 = 1, Bit 1 (ROS) of parameter No. 1006 = 0) 

 

Bit 6 (RON) of parameter No. 1815 = 0 

By setting the bit to 0, alarm DS0300 is issued and the zero point of the absolute position detector must 

always be set again, which prevents malfunction caused if zero point setting is not performed again. 

At this time, bit 0 (PR1) of diagnosis data No. 310 is set to 1. 

 

Information of setting the zero point   

The method of setting the zero point can be confirmed by diagnosis data No.3520. 

 

When the servo axis is disabled (bit 4 (KSVx) of parameter No. 11802 is set to 

1) 

An absolute position detector cannot be used (bit 5 (APCx) of parameter No. 1815 cannot be set to 1). 

If an absolute position detector is used, alarm SV0301, "APC ALARM; COMMUNICATION ERROR" 

is issued. 

 

Signal 

Absolute position detector battery voltage low alarm signal PBATL<Fn172.7> 

  [Classification]  Output signal 

 

[Function]  Notifies that the life of the absolute position detector battery is about to expire. 

 

[Operation]  These signal is “1” in the following case: 

1. AXIS CONTROL

 

 

B-64693EN-1/01

 

- 102 - 

The battery voltage for the absolute position detector becomes lower than or equal to 

the rating. The battery need be replaced in the immediate future. 

These signal is “0” in the following case: 

The battery voltage for the absolute position detector is higher than or equal to the 

rating. 

 

Absolute position detector battery voltage zero alarm signal PBATZ<Fn172.6> 

  [Classification]  Output signal 

 

[Function]  Notifies that the life of the absolute position detector battery has expired. 

 

[Operation]  These signals are “1” in the following case: 

The batteries for the absolute position detector have run out. The batteries need be 

replaced in the status in which the power to the machine is on. 

These signals are “0” in the following case: 

The batteries for the absolute position detector feed the voltage required for data 

backup. 

 

Signal address 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

Fn172 

 

PBATL   

PBATZ 

 

 

 

 

 

 

 

Diagnosis data 

Why bit 4 (APZ) of parameter No. 1815 is set to 0 can be checked using diagnosis data Nos. 310 and 311. 

After any bit of diagnosis data Nos. 310 and 311 is set to 1, it remains set to 1 until the zero point of the 

absolute position detector on the axis is set. Each bit of diagnosis data Nos. 310 and 311 is described 

below with its corresponding cause. 

 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

310 

 

 

DTH 

ALP 

 

BZ2 

BZ1 

PR2 

PR1 

 

 

PR1  One of the following parameters were changed: 

No.1815#0, No.1815#1, No.1815#6, No.1817#3, No.1820, No.1821, No.1822, No.1823, 

No.1850, No.1868, No.1869, No.1874, No.1875, No.1876, No.1878, No.1883, No.1884, 

No.2022, No.2084, No.2085, No.2179, increment system for a rotary axis A type (see 

“Explanation” for details.), No.11802#6, No.11810 

 

PR2  The value of bit 1 (ATS) of parameter No. 8303 was changed. Alternatively, when bit 7 

(SMA) of parameter No. 8302 was set to 1, APZ of the relevant axis for synchronous 

operation became 1. 

 

BZ1  A battery voltage of 0 V was detected. (Inductosyn) 

 

BZ2  A battery voltage of 0 V was detected. (separate position detector) 

 

ALP  Although the 

a

 Pulsecoder did not indicate one turn, the zero point was set using MDI 

operation. 

Alternatively, the CNC could not obtain a valid value from the absolute Pulsecoder. 

 

DTH  An axis was released from control by using controlled axis detach signal DTCH 

<Gn124> or bit 7 (RMV) of parameter No. 0012. 

 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

311 

 

 

DUA 

XBZ 

GSG 

AL4 

AL3 

AL2 

AL1 

 

 

AL1  SV alarms SV0301 to SV0305 were issued. 

 

AL2  When bit 1 (CRF) of parameter No. 1819 was 1, soft disconnect alarm SV0445 or 

SV0447 or abnormal analog signal alarm SV0646 was detected. 

 

AL3  A battery voltage of 0 V was detected. (built-in serial Pulsecoder) 

 

AL4  Count miss alarm SV0367 was detected. 

 

GSG  Disconnection alarm ignore signal NDCAL <Gn202> was changed from “1” to “0”. 

B-64693EN-1/01

 

 

1. AXIS CONTROL

 

- 103 - 

 

XBZ  A battery voltage of 0 V or count miss alarm SV0382 was detected. (separate position 

detector installed for each serial method) 

 

DUA  When bit 1 (CRF) of parameter No. 1819 was 1, excess error (semi-full) alarm SV0421 

was detected. 

 

If a battery low alarm is issued, the cause of the issuance can be checked with diagnosis data No. 3019. 

 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

3019 

 

 

 

EXP 

INP 

ABP 

 

 

 

 

 

[Data type]  Axis 

 

ABP  Battery low in the phase A/B 

 

ANP  Battery low in the serial Pulsecoder (built-in position detector) 

 

EXP  Battery low in the serial separate position detector 

 

3520 

 

Information of setting the zero point for absolute position detection 

 

 

[Data type]  Byte axis 

 

[Unit of data]  None 

[Valid data range]  0 to 3 

To set the zero point of absolute position detection: 

0 : is not performed yet. 

1 : was performed by the manual reference position return. 

2 : was performed by MDI operation. 

3 : was performed by the reading of parameter file. 

 

Parameter 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

1803 

 

NFP 

 

 

 

 

 

 

 

 

 

[Input type]  Parameter input 

 

[Data type]  Bit path 

 

 

#7  NFP

  If position matching between the machine position and absolute position detector is not 

performed even once, follow-up operation is: 

0:  Not performed. 

1:  Performed. 

 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

1815 

 

 

RONx 

APCx 

APZx 

 

 

OPTx 

 

 

 

[Input type]  Parameter input 

 

[Data type]  Bit axis 

 

NOTE 

  When at least one of these parameters is set, the power must be 

turned off before operation is continued. 

 

 

#1  OPTx

  The separate position detector is: 

0:  Not to be used (semi-closed system) 

1:  To be used (full-closed system) 

 

1. AXIS CONTROL

 

 

B-64693EN-1/01

 

- 104 - 

NOTE 

  In case of using the absolute position detector (bit 5 (APCx) of 

parameter No.1815 is set to 1), please set the following parameters 

that correspond to the absolute position detector which is actually 

used. 

-  parameter No.1815#6, No.1815#0, No.1817#3, No.1868,   

 No.2275#1, No.2394 

If these parameters are not set correctly, the machine coordinates 

are not correctly established at power-on. 

 

 

#4  APZx

  Machine position and position on absolute position detector when the absolute position 

detector is used   

0:  Not corresponding 

1:  Corresponding 

When an absolute position detector is used, after primary adjustment is performed or after 

the absolute position detector is replaced, this parameter must be set to 0, power must be 

turned off and on, then manual reference position return must be performed. This 

completes the positional correspondence between the machine position and the position 

on the absolute position detector, and sets this parameter to 1 automatically. 

 

 

#5  APCx

  Position detector 

0:  Other than absolute position detector 

1:  Absolute position detector (absolute Pulsecoder) 

 

NOTE 

1  In case of using FANUC absolute pulsecoder as absolute position 

detector for the rotary axis A type that machine coordinate values 

are rounded in 0 to 360°, set bit 6 (RON) of parameter No.1815 to 0. 

If the parameter is not set correctly, the machine coordinates are 

not correctly established at power-on. 

2  In case of using a rotary scale without rotary data made by another 

company as absolute position detector, please refer to 

"CORRESPONDENCE OF ROTARY SCALE WITHOUT ROTARY 

DATA" in this manual and set an appropriate value corresponding 

to the detector. If the parameter is not set correctly, the machine 

coordinates are not correctly established at power-on. 

3  When the servo axis is disabled (bit 4 (KSVx) of parameter No. 

11802 is set to 1), an absolute position detector cannot be used (bit 

5 (APCx) of parameter No. 1815 cannot be set to 1). If an absolute 

position detector is used, alarm SV0301, "APC ALARM; 

COMMUNICATION ERROR" is issued. 

 

 

#6  RONx

  With a rotary axis A type, a rotary encoder for detecting an absolute position within one 

revolution is: 

0:  Not used. 

1:  Used. 

 

B-64693EN-1/01

 

 

1. AXIS CONTROL

 

- 105 - 

NOTE 

1  This parameter is available for only the rotary axis A type with an 

absolute position detector (absolute Pulsecoder).This function 

cannot be used for a rotary scale with distance-coded reference 

marks (serial) or for a distance coded rotary scale interface (phase 

A/B). 

2  Set this parameter to 1 for the rotary axis A type using a rotary scale 

without rotary data such as HEIDENHAIN rotary scale RCN 223F, 

727F, etc. 

  Set this parameter to 0

 

in any other case. If the parameter is not set 

correctly, the machine coordinates are not correctly established at 

power-on. 

3  When this parameter is set, machine position and position on 

absolute position detector become uncorresponding. Consequently, 

the bit 4 (APZ) parameter No. 1815 (indicating that the 

correspondence is established) is set to 0, and alarm DS0300 is 

issued. Why the parameter bit 4 (APZ) parameter No. 1815 is set to 

0 can be checked using bit 0 of diagnosis data No. 310. 

 

 

 

#7 

#6 

#5 

#4 

#3 

#2 

#1 

#0 

1817 

 

 

 

 

 

SCRx 

 

 

 

 

 

[Input type]  Parameter input 

 

[Data type]  Bit axis 

 

NOTE 

  When at least one of these parameters is set, the power must be 

turned off before operation is continued. 

 

 

#3  SCRx

  Specifies whether to convert scale data by using threshold position (parameter No. 1868) 

so that rotary axis B type is available, in the case of the axis B type that use a rotary scale 

without data (the number of rotation), whose movable range is under one rotation: 

0 :  Not to convert. 

1 :  To convert. 

 

NOTE 

1  This parameter is available for only the rotary axis B type with an 

absolute position detector (absolute Pulsecoder) or a rotary scale 

with distance-coded reference marks (serial). This function cannot 

be used for distance coded rotary scale interface (phase A/B). 

2  Don't set this parameter in the case of no uncontinuous point within 

movable range of rotary axis even if the rotary axis B type. 

3  When this parameter is set, machine position and position on 

absolute position detector become uncorresponding. Consequently, 

the bit 4 (APZ) of parameter No. 1815 (indicating that the 

correspondence is established) is set to 0, and alarm DS0300 is 

issued. Why the bit 4 (APZ) of parameter No. 1815 is set to 0 can be 

checked using bit 0 of diagnosis data No. 310. 

 

 

 

 

 

 

 