33

FEATURES

Instrumentation

MFD Digital Display Programs

Performance Program
Clock Setting
1. While in the CLOCK display, press

and hold the SET button for five

seconds.

2. When the hour starts flashing press

the SET switch once to advance one

hour, or press and hold the SET

button to advance the hour once

every 0.2 seconds.

3. Press the MODE button to save the hour and flash the minutes.
4. Set the minutes in the same manner.
5. When finished, press the MODE button to save the new setting.

NOTE: If the MODE button is not pressed within ten seconds, the

clock will automatically save the new entry.

Engine Program
The Engine Program automatically displays the engine coolant

temperature, engine hours, electrical system voltage level and fuel

level. On machines equipped with altimeter sensor and ambient air

temperature sensors, altitude and ambient air temperature will display

as additional screens in the engine program. Press the SET button to

display the ambient air temperature and altitude screens (if equipped).
Air Temperature (if equipped)
The MFD displays actual air temperature.

Press and hold the MODE switch for ten

seconds to switch between standard and

metric units of measurement.

34

FEATURES

Instrumentation

MFD Digital Display Programs

Altitude (if equipped)
The rider can calibrate the altimeter for

current atmospheric conditions. Altimeter

accuracy will be +/-300 ft. (91 m) after

adjustment.

NOTE: Press and hold the MODE switch

for ten seconds to switch

between standard and metric units of measurement. When

“ALt” displays, the program is in the metric mode.

1. Enter the Engine Program and select the altimeter display.
2. Press and hold the SET button for five seconds.
3. When the digits begin to flash, press the SET button once to

advance 50 feet (15 m), or press and hold the button to advance

100 ft. (30 m) every 0.1 seconds. Adjust the altitude display to

within 50 ft. (15 m) of current altitude.

NOTE: The gauge reads barometric pressure and allows the rider to

compensate for daily fluctuations in air pressure. The gauge

can adjust the displayed altitude to +/- 1300 ft. (396 m) from

the preset value. It will adjust up to +1300 ft. (396 m) above

the calibrated altitude. Once the +1300 ft. (396 m) offset has

been reached, the next adjustment is -1300 ft. (396 m) from

the calibrated altitude, and 50 ft. (15 m) will be added to the

altitude each time the SET button is pressed.

4. Press the MODE button to hold the reading at the adjusted value. If

it’s not pressed within five seconds, the gauge will automatically

save the new setting.

Hour Meter
The hour meter records the total hours of

engine operation since manufacture. This

meter cannot be reset.

Engine Temperature
A thermometer measures water temperature,

giving an indication of engine temperature.

35

FEATURES

Instrumentation

MFD Digital Display Programs

History Program
The History Program automatically displays electrical system voltage

level and fuel level.
While in the History mode, press the SET button to view maximum

vehicle speed, maximum engine rpm or the current service interval

setting. The gauge automatically logs the maximum speed and engine

rpm even if the History Program is not currently displayed.
The History Program will display the history of the Maximum Speed,

Maximum RPM and Service Interval settings.
Maximum Speed/RPM Reset
While in either the MAX MPH or the

MAX RPM mode, press and hold the

SET button for three seconds to reset

the recorded maximum values for both

MPH and RPM. Both of these values

are reset at the same time. Reset the

MAX MPH/RPM values before each

run to obtain accurate readings.

NOTE: Due to electrical noise, the

MFD may occasionally

display MAX MPH/RPM

values that are not

representative of actual

values.

36

FEATURES

Instrumentation

MFD Digital Display Programs

Service Interval Reminder
The gauge logs the number of engine

hours between service reminders.

When the logged hours reaches the

designated service interval (set by the

user), the gauge provides a reminder

that service is due. “SErVCE” will

flash in the odometer area and “ENG”

will flash in the icon area for five

seconds each time the vehicle is

started until the service reminder is reset.
To reset the reminder at the existing interval:
1. Enter the service interval screen.
2. Press and hold the SET button for ten seconds, continuing to hold

even after the display begins to flash.

3. When the display stops flashing, release the button. The service

interval has been reset.

To reset the reminder at a new interval:
1. Enter the service interval screen.
2. Press and hold the SET button for five seconds, until the hours

begin to flash.

3. Immediately release the button.
4. Press the button again up to five times to advance the reminder in

50-hour increments.

NOTE: The maximum interval is 250 hours.

To disable the service interval reminder, press the SET button once

after reaching 250 hours on the display. The gauge will display

“OFF”.

 

 

 

 

 

 

 

Content   ..  6  7  8  9   ..