NC variables
3.2 NC variable descriptions
see VDI interface NCK->PLC axis-specific
DBB64 Bit6 and Bit7 (Bit6 = motion command-, Bit7 = motion command+)
Event occurs if both bits are set to 0 and one of them was previously active.
Acyclic events related to channel influence:
6 = NC_START
NC start (if detected in NC)
7 = NC_STOP
NC stop (if detected in NC, axes may still be traversed)
60 = CHAN_STATE
The channel state changes (from SW $[[SW991806]])
61 = PROG_STATE
The program state changes (from SW $[[SW991806]])
Acyclic events related to part program processing:
8 = BLOCK_BEG_1 and
Block start (first IPO cycle of a block) without intermediate blocks, all program
levels
52 = BLOCK_BEG_1a
9 = BLOCK_BEG_2 and Block start (first IPO cycle of a block) with intermediate blocks, all program levels
20 = BLOCK_BEG_2a
56 = BLOCK_BEG_2b
57 = BLOCK_BEG_2c
10 = BLOCK_BEG_3 Block start (first IPO cycle of a block) without intermediate blocks, only main program
level and MDI level
16 = BLOCK_BEG_S1 and Block start (search run with computation) with intermediate blocks, all program
levels
22 = BLOCK_BEG_S1a
11 = BLOCK_END_1 Block end (first IPO cycle of a block) without intermediate blocks, all program levels
12 = BLOCK_END_2 and Block end (first IPO cycle of a block) with intermediate blocks, all program levels
21 = BLOCK_END_2a
13 = BLOCK_END_3 Block end (first IPO cycle of a block) without intermediate blocks, only main program
level and MDI level
17 = BLOCK_END_S1 Block end (search run with computation)
with intermediate blocks, all program
levels
31 = BLOCK_END_P1
Block end (run in)
(from SW $[[SW530000]])
32 = BLOCK_END_P1a
Block end (run in)
(from SW $[[SW530000]])
44 = BLOCK_END_I1
Block end (interpreter)
(from SW $[[SW510300]])
43 = NC_LEVEL_CHG
Level change during part program processing (from SW $[[SW510300]])
Acyclic events triggered by part program command WRTPR
NC variables
118
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
23 = PROT_TXT_REQ
Logging a WRTPR text
24 = PROT_TXT_REQ_S1
Logging a WRTPR text (search run with computation)
33 = PROT_TXT_REQ_P1
Logging a WRTPR text (run in) (from SW $[[SW510300]])
Acyclic events triggered by the logging process itself
14 = PROT_FILE_BEG
Start logging related to a log file.
29 = PROT_START_TRIG
Start trigger has triggered
(from SW $[[SW510300]])
30 = PROT_STOP_TRIG
Stop trigger has triggered
(from SW $[[SW510300]])
46 = PROT_START
Start logging
(from SW $[[SW510300]])
45 = PROT_STOP
Stop logging
(from SW $[[SW510300]])
Acyclic events triggered by buttons
42 = CANCEL_BUTTON
The Cancel button was pressed
(from SW $[[SW510300]])
Acyclic events triggered by alarms
41 = ALARM_REPORTED
An alarm has occurred
(from SW $[[SW510300]])
Acyclic events triggered by synchronized action
36 = SYNC_ACT_ACTIV
Activating synchronized action
(from SW $[[SW510300]])
37 = SYNC_ACT_DEACT
Deactivating synchronized action
(from SW $[[SW510300]])
38 = SYNC_ACT_FIRE
Synchronized action triggers
(from SW $[[SW510300]])
Acyclic events triggered by tool
25 = TOOL_CHANGE
tool change
(from SW $[[SW420000]])
27 = TOOL_CHANGE_S1
tool change (search run with computation) (from SW $[[SW440000]])
34 = TOOL_CHANGE_P1
tool change (run in)
(from SW $[[SW510300]])
26 = CUTTEDGE_CHANGE
cutting edge change
(from SW $[[SW420000]])
28 = CUTTEDGE_CHANGE_S1 cutting edge change (search run with computation) (from SW $[[SW440000]])
35 = CUTTEDGE_CHANGE_P1 cutting edge change (run in)
(from SW $[[SW510300]])
Acyclic events triggered by PLC
39 = PLC_OB_1
PLC OB1 started
(from SW $[[SW510300]])
40 = PLC_OB40
PLC OB40 started
(from SW $[[SW510300]])¶
asciiMode (C, ETP)
Data logging format
Return value
0: Data recorded in binary format with fixed alignment to 8 bytes
1: Data recorded in ASCII format
2: Data recorded in binary format with variable alignment
3: Data recorded in binary format with variable alignment and optimization of two consecutive
data records of the same event. In this case, only the header is logged, not the actual data.
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
119
NC variables
3.2 NC variable descriptions
asciiMode (C, ETP)
-
TYPE_UWORD
0
0
3
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access and write access
countActivated (C, ETP)
Number of occurrences of event
Number of times the event has occurred
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_UWORD
0
Read access
countActivatedL (C, ETP)
Number of times the event has occurred.
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DWORD
0
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access
dataListIndex (C, ETP)
Index of data list
Index of data list to be used
Return value
All valid columns in module ETPD - 1)
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access and write access
dataProtok (C, ETP)
Bytes written to the Fifo file
Number of bytes entered in the Fifo file
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DWORD
0
Read access
NC variables
120
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
dataUploaded (C, ETP)
Bytes read to the Fifo file
Number of bytes already uploaded from the Fifo file
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DWORD
0
Read access
eventActive (C, ETP)
Event state
Return value
0: Not active
1: Active
2: Deactivate and release data set
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
0
2
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access and write access
eventActiveStatus (C, ETP)
State
For diagnosis: Event state
Return value
0: Activated
1: Not activated
2: Cannot be activated because the sum of the variable lengths is too large
3: Cannot be activated because the internal resources are not sufficient
4: Cannot be activated because the protocol file cannot be created
100-...- cannot be activated because the variable specification with the index (value - 100) is
wrong
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
121
NC variables
3.2 NC variable descriptions
headerType (C, ETP)
Type of header in the data record
Return value
0: No header
1: Short header with the following structure:
UDword dataStamp;
// Data record identified by a consecutive number
UWord event;
// Enter type of event that occurred
UWord protCount;
// The number of times the event has been logged
2: Long header with the following structure:
UDword dataStamp;
// Data record identified by a consecutive number
UWord event;
// Enter type of event that occurred
UByte chan;
// Channel in which the event occurred
UByte dummy1;
// Still free
UDword protCount;
// The number of times the event has been logged
UDword dummy2;
// Still free
3: Mid-length header, non-aligned with the following structure:
UDword dataStamp;
// Data record identified by a consecutive number
UWord event;
// Enter type of event that occurred
UByte chan;
// Channel in which the event occurred
UByte dummy1;
// Still free
UDword protCount;
// The number of times the event has been logged
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
1
0
3
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access and write access
maxElementsFastFifoUsed (C, ETP)
Maximum Fifo buffer fill level reached
For diagnosis: Maximum number of entries in the FIFO buffer
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access
maxFileLength (C, ETP)
Maximum length of log file
Maximum length of the log file.
Values less than 1024 are interpreted as KB, larger values as bytes. The minimum permissible length is 3000.
NC variables
122
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
maxFileLength (C, ETP)
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access and write access
maxGrossFileLengthUsed (C, ETP)
Maximum log file size
For diagnosis: Maximum gross size of log file
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access
maxNetFileLengthTooSmall (C, ETP)
Number of bytes log file undersized
For diagnosis: Number of (net) bytes by which log file is undersized
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access
numElementsFastFifoTooSmall (C, ETP)
Number of entries Fifo buffer undersized
For diagnosis: Number of entries by which the Fifo buffer is undersized
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
123
NC variables
3.2 NC variable descriptions
protocolFilename (C, ETP)
Log file name
Name of the log file including the path
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_STRING
0
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access and write access
resultPar1 (C, ETP)
General result value
General result value, the significance is a function of the event.
SYNC_ACT_ACTIVATE, SYNC_ACT_DEACTIVATE, and SYNC_ACT_FIRE: ID of the synchronous action.
All non-stated events do not supply this result value.
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_UWORD
0
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access
skip (C, ETP)
Number of events to be skipped
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access and write access
startTriggerLock (C, ETP)
Processing block for the start trigger
Setting, whether the start trigger is not to be processed during this event.
Return value
0: Trigger is processed
1: Trigger is not processed
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
0
1
Read access and write access
NC variables
124
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
stopTriggerLock (C, ETP)
Processing block for the stop trigger
Setting, whether the stop trigger is not to be processed during this event.
Return value
0: Trigger is processed
1: Trigger is not processed
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
0
1
Read access and write access
suppressProtLock (C, ETP)
$$traceProtocolLock is inactive
Clears the effect of $$traceProtocolLock
Return value
0: The disable is active
1: The disable is canceled for this event
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
0
1
Addressing
Line index:
Max. line index:
1
Read access and write access
timePeriod (C, ETP)
Time base
Time base for cyclic event only
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
ms
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
siehe Bausteinkopf
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
125
NC variables
3.2 NC variable descriptions
3.2.3.7
FA: Active Work Offset
OEM-MMC: LinkItem /Channel/ActualFrame/...
The following frame indices are available:
0: $P_ACTFRAME = current resulting work offset
1: $P_IFRAME = current settable work offset
2: $P_PFRAME = current programmable work offset
3: EXTFRAME = current external work offset
4: TOTFRAME = current total work offset = sum of ACTFRAME and EXTFRAME
5: $P_ACTBFRAME = current total base frame
6: $P_SETFRAME = current 1st system frame (set actual value, scratching)
7: $P_EXTSFRAME = current 2nd system frame (set actual value, scratching)
8: $P_PARTFRAME = current 3rd system frame (TCARR and PAROT with orientable tool carrier)
9: $P_TOOLFRAME = current 4th system frame (TOROT and TOFRAME)
10: $AC_MEASFRAME = result frame for workpiece and tool measurement
11: $P_WPFRAME = current 5th system frame (workpiece reference points) as from SW $[[SW440000]]
12: $P_CYCFRAME = current 6th system frame (cycles) as from SW $[[SW440000]]
13: $P_TRAFRAME = current 7th system frame (transformation) as from SW $[[SW520000]]
14: $P_ISO1FRAME = current ISO system frame for G51.1 mirroring as from SW $[[SW660000]]
15: $P_ISO2FRAME = current ISO system frame for G68 2DROT
as from SW $[[SW660000]]
16: $P_ISO3FRAME = current ISO system frame for G68 3DROT
as from SW $[[SW660000]]
17: $P_ISO4FRAME = current ISO system frame for G51 scale as from SW $[[SW660000]]
18: $P_ACSFRAME = current resulting frame for the SZS (ACS) as from SW $[[SW660000]]
19: $P_RELFRAME = current 12th system frame for relative coordinate systems as from SW $[[SW700000]]
20: $P_TRAFRAME_P = current frame of the workpiece component of an active kinematic (orientation) transfor-
mation as from SW $[[SW900000]]
21: $P_TRAFRAME_T = current frame of the tool component of an active kinematic (orientation) transformation as
from SW $[[SW900000]]
The maximum frame index is 21.
linShift (C, FA)
diverse, siehe Bausteinbescheibung
PA
Translation of an active frame
Translation of an active work offset (the physical unit is defined in basicLengthUnit in module Y in area N).
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
20 * $$numMachAxes
Read access
NC variables
126
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
linShiftFine (C, FA)
diverse, siehe Bausteinbescheibung
Fine offset of an active frame
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
20 * $$numMachAxes
Read access and write access
mirrorImgActive (C, FA)
diverse, siehe Bausteinbescheibung
PA
Mirroring enabled in an active frame
Mirroring enabled in an active work offset
Return value
0 = mirroring not active
1 = mirroring active
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
20 * $$numMachAxes
Read access
rotation (C, FA)
diverse, siehe Bausteinbescheibung
PA
Rotation of an active frame
Rotation of an active work offset
Units and value ranges
Physical unit:
Data type:
Degree
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
20 * $$numMachAxes
Read access
rotationCoordinate (C, FA)
Coordinate rotation of active frames
Rotation around a coordinate of an active work offset
1: Rotation around the first non-existing geometry axis.
Units and value ranges
Physical unit:
Data type:
Degree
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
127
NC variables
3.2 NC variable descriptions
rotationCoordinate (C, FA)
20 * $$numMachAxes
Read access
scaleFact (C, FA)
diverse, siehe Bausteinbescheibung
PA
Scaling factor of an active frame
Scaling factor of an active work offset
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
20 * $$numMachAxes
Read access
3.2.3.8
FB: Base Frame
OEM-MMC: LinkItem /Channel/BaseFrame/...
This only applies if $MC_MM_NUM_BASE_FRAMES > 0.
The maximum frame index is: $MC_MM_NUM_BASE_FRAMES - 1
linShift (C, FB)
$P_CHBFR[x,y,TR] x=FrameNo, y=Axis
PA
Translation of a settable frame
Translation of settable work offset (the physical unit is defined in basicLengthUnit in module Y in area N).
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_BASE_FRAMES * ($$numGeoA-
xes + $$numAuxAxes)
Read access and write access
linShiftFine (C, FB)
$P_CHBFR[x,y,FI] x=FrameNo, y=Axis
Fine offset for frames
Fine offset with frames, expansion of basic frames and settable frames
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
NC variables
128
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
linShiftFine (C, FB)
$P_CHBFR[x,y,FI] x=FrameNo, y=Axis
$MC_MM_NUM_BASE_FRAMES * ($$numGeoA-
xes + $$numAuxAxes)
Read access and write access
mirrorImgActive (C, FB)
$P_CHBFR[x,y,MI] x=FrameNo, y=Axis
PA
Mirroring enabled in a settable frame
Mirroring enabled in a settable work offset
Return value
0: Mirroring not active
1: Mirroring active
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$MC_MM_NUM_BASE_FRAMES * ($$numGeoA-
xes + $$numAuxAxes)
Read access and write access
rotation (C, FB)
$P_CHBFR[x,y,RT] x=FrameNo, y=Axis
PA
Rotation of a settable frame
Rotation of a settable work offset
Units and value ranges
Physical unit:
Data type:
Degree
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_BASE_FRAMES * ($$numGeoA-
xes + $$numAuxAxes)
Read access and write access
rotationCoordinate (C, FB)
Coordinate rotation of settable frames
Rotation around coordinate of a channel base frame
1: Rotation around first non-existing geometry axis.
Units and value ranges
Physical unit:
Data type:
Degree
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_BASE_FRAMES * ($$numGeoA-
xes + $$numAuxAxes)
Read access and write access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
129
NC variables
3.2 NC variable descriptions
scaleFact (C, FB)
$P_CHBFR[x,y,SC] x=FrameNo, y=Axis
PA
Scaling factor of a settable frame
Scaling factor of a settable work offset
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_BASE_FRAMES * ($$numGeoA-
xes + $$numAuxAxes)
Read access and write access
3.2.3.9
FE: External Work Offset
OEM-MMC: LinkItem /Channel/ExternFrame/...
There is exactly one external frame defined by the PLC.
The maximum frame index is: 0
linShift (C, FE)
$AA_ETRANS[x] x = FrameNo
PA
Translation of an external frame
Translation of external work offset (the physical unit is defined in basicLengthUnit in module Y in area N).
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numGeoAxes
Read access and write access
linShiftFine (C, FE)
diverse, siehe Bausteinbescheibung
Fine offset of external frame
Fine offset of external work offset
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numGeoAxes
Read access and write access
NC variables
130
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
mirrorImgActive (C, FE)
diverse, siehe Bausteinbescheibung
PA
Mirroring of an external frame
Mirroring of an external work offset
Return value
0 = mirroring not active
1 = mirroring active
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
20 * $$numMachAxes
Read access
rotation (C, FE)
diverse, siehe Bausteinbescheibung
PA
Rotation of an external frame
Rotation of an external work offset
Units and value ranges
Physical unit:
Data type:
Degree
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
20 * $$numMachAxes
Read access
rotationCoordinate (C, FE)
Coordinate rotation external work offset
Rotation around coordinate of an external work offset
1: Rotation around first non-existing geometry axis.
Units and value ranges
Physical unit:
Data type:
Degree
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
20 * $$numMachAxes
Read access
scaleFact (C, FE)
diverse, siehe Bausteinbescheibung
PA
Scaling factor of external frame
Scaling factor of an external work offset
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
131
NC variables
3.2 NC variable descriptions
scaleFact (C, FE)
diverse, siehe Bausteinbescheibung
PA
Addressing
Line index:
Max. line index:
20 * $$numMachAxes
Read access
3.2.3.10
FG: Frames for grinding applications
OEM-MMC: LinkItem /Channel/GrindingFrame/...
These occur only if $MC_MM_NUM_G_FRAMES > 0 and $MN_MM_NUM_GLOBAL_G_FRAMES = 0, otherwise all
grinding frames are configured globally for the NCU.
The following frame indices are possible:
0: GRAME1
1: GRAME2
2: GRAME3
3: GRAME4
n: GRAMEn
99: GRAME100
The maximum frame index is: $MC_MM_NUM_G_FRAMES - 1
The PI service SETUFR has to be called to activate the grinding frames.
linShift (C, FG)
$P_GFR[x,y,TR] x=FrameNo,y=Axis
PA
Translation of grinding frame
Translation of grinding frame (the physical unit is defined in basicLengthUnit in block Y in area N).
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_G_FRAMES * ($$numGeoAxes
+ $$numAuxAxes)
Read access and write access
linShiftFine (C, FG)
$P_GFR[x,y,FI] x=FrameNo,y=Axis
Fine offset for frames
Fine offset with frames, expansion of basic frames and settable frames
Units and value ranges
Physical unit:
Data type:
NC variables
132
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
linShiftFine (C, FG)
$P_GFR[x,y,FI] x=FrameNo,y=Axis
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_G_FRAMES * ($$numGeoAxes
+ $$numAuxAxes)
Read access and write access
mirrorImgActive (C, FG)
$P_GFR[x,y,MI] x = FrameNo,y=Axis
PA
Mirroring of grinding frame
Mirroring
Return value
0 = mirroring not active
1 = mirroring active
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$MC_MM_NUM_G_FRAMES * ($$numGeoAxes
+ $$numAuxAxes)
Read access and write access
rotation (C, FG)
$P_GFR[x,y,RT] x = FrameNo,y=Axis
PA
Rotation of grinding frame
Rotation
Units and value ranges
Physical unit:
Data type:
Degree
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_G_FRAMES * ($$numGeoAxes
+ $$numAuxAxes)
Read access and write access
rotationCoordinate (C, FG)
Rotation of grinding frame coordinate
Rotation around a coordinate.
1: Rotation around the first non-existent geometry axis.
Units and value ranges
Physical unit:
Data type:
Degree
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
133
NC variables
3.2 NC variable descriptions
rotationCoordinate (C, FG)
$MC_MM_NUM_G_FRAMES * ($$numGeoAxes
+ $$numAuxAxes)
Read access and write access
scaleFact (C, FG)
$P_GFR[x,y,SC] x = FrameNo,y=Axis
PA
Scaling factor of grinding frame
Scaling factor
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_G_FRAMES * ($$numGeoAxes
+ $$numAuxAxes)
Read access and write access
3.2.3.11
FS: System Frame
OEM-MMC: LinkItem /Channel/SystemFrame/...
Those that exist are set by the bits in $MC_MM_SYSTEM_FRAME_MASK.
Consequently, there may be gaps between the active system frames.
The maximum frame index is:
3 up to but excluding SW $[[SW440000]].
5 from and including SW $[[SW440000]].
11 as from and including SW $[[SW660000]].
12 as from and including SW $[[SW700000]].
linShift (C, FS)
$P_SETFR[Achse, TR]
Translation
Units and value ranges
Physical unit:
Data type:
Initial value
mm, inch, user defined
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
12 * ($$numGeoAxes+$$numAuxAxes)
Read access and write access
linShiftFine (C, FS)
$P_SETFR[Achse, FI]
Fine offset of a system frame
Fine offset
NC variables
134
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
linShiftFine (C, FS)
$P_SETFR[Achse, FI]
Units and value ranges
Physical unit:
Data type:
Initial value
mm, inch, user defined
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
12 * ($$numGeoAxes+$$numAuxAxes)
Read access and write access
mirrorImgActive (C, FS)
$P_SETFR[Achse, MI]
Mirroring a system frame
Mirroring
Return value
0: Mirroring not active
1: Mirroring active
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
0
1
Addressing
Line index:
Max. line index:
12 * ($$numGeoAxes+$$numAuxAxes)
Read access and write access
rotation (C, FS)
$P_SETFR[Achse, RT]
Rotation of a system frame
Rotation
Units and value ranges
Physical unit:
Data type:
Initial value
Degree
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
12 * ($$numGeoAxes+$$numAuxAxes)
Read access and write access
rotationCoordinate (C, FS)
Coordinate rotation of a system frame
Rotation around a coordinate of a system frame
1: Rotation around first non-existing geometry axis.
Units and value ranges
Physical unit:
Data type:
Initial value
Degree
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
12 * ($$numGeoAxes+$$numAuxAxes)
Read access and write access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
135
NC variables
3.2 NC variable descriptions
scaleFact (C, FS)
$P_SETFR[Achse, SC]
Scaling factor of a system frame
Scaling factor
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
12 * ($$numGeoAxes+$$numAuxAxes)
Read access and write access
3.2.3.12
FU: Settable Work Offset
OEM-MMC: LinkItem /Channel/UserFrame/...
This only applies if $MC_MM_NUM_USER_FRAMES > 0 and $MN_MM_NUM_GLOBAL_USER_FRAMES = 0, other-
wise all settable frames have an NCU-global configuration.
The following frame indices are possible:
0 = G500
1 = G54
2 = G55
3 = G56
4 = G57
5 = G505
6 = G506
:
n = G5n
:
99 = G599
The maximum frame index is: $MC_MM_NUM_USER_FRAMES - 1
The PI service SETUFR has to be called in order to activate the settable frames.
linShift (C, FU)
$P_UIFR[x,y,TR] x=FrameNo,y=Axis
PA
Translation of a settable frame
Translation of settable work offset (the physical unit is defined in basicLengthUnit in module Y in area N).
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
NC variables
136
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
linShift (C, FU)
$P_UIFR[x,y,TR] x=FrameNo,y=Axis
PA
$MC_MM_NUM_USER_FRAMES * ($$numGeoA-
xes + $$numAuxAxes)
Read access and write access
linShiftFine (C, FU)
$P_UIFR[x,y,FI] x=FrameNo,y=Axis
Fine offset for frames
Fine offset with frames, expansion of basic frames and settable frames
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_USER_FRAMES * ($$numGeoA-
xes + $$numAuxAxes)
Read access and write access
mirrorImgActive (C, FU)
$P_UIFR[x,y,MI] x = FrameNo,y=Axis
PA
Mirroring enabled in a settable frame
Mirroring enabled in a settable work offset
Return value
0 = mirroring not active
1 = mirroring active
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$MC_MM_NUM_USER_FRAMES * ($$numGeoA-
xes + $$numAuxAxes)
Read access and write access
rotation (C, FU)
$P_UIFR[x,y,RT] x = FrameNo,y=Axis
PA
Rotation of a settable frame
Rotation of a settable work offset
Units and value ranges
Physical unit:
Data type:
Degree
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_USER_FRAMES * ($$numGeoA-
xes + $$numAuxAxes)
Read access and write access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
137
NC variables
3.2 NC variable descriptions
rotationCoordinate (C, FU)
Coordinate rotation of settable frames
Rotation around a coordinate of a settable work offset
1: Rotation around first non-existing geometry axis.
Units and value ranges
Physical unit:
Data type:
Degree
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_USER_FRAMES * ($$numGeoA-
xes + $$numAuxAxes)
Read access and write access
scaleFact (C, FU)
$P_UIFR[x,y,SC] x = FrameNo,y=Axis
PA
Scaling factor of a settable frame
Scaling factor of a settable work offset
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_USER_FRAMES * ($$numGeoA-
xes + $$numAuxAxes)
Read access and write access
3.2.3.13
M: Machine data
OEM-MMC: LinkItem /Channel/Drive/...
Channel-specific machine data
ADD_MOVE_ACCEL_RESERVE (C, M)
MD 20610: $MC_ADD_MOVE_ACCEL_RE-
SERVE
MD 20610: $MC_ADD_MOVE_ACCEL_RESERVE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
ALLOW_G0_IN_G96 (C, M)
MD 20750: $MC_ALLOW_G0_IN_G96
MD 20750: $MC_ALLOW_G0_IN_G96
Units and value ranges
Physical unit:
Data type:
NC variables
138
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
ALLOW_G0_IN_G96 (C, M)
MD 20750: $MC_ALLOW_G0_IN_G96
-
TYPE_BOOLEAN
Read access
AUXFU_ASSIGN_EXTENSION (C, M)
MD 22020: $MC_AUXFU_ASSIGN_EXTEN-
SION
MD 22020: $MC_AUXFU_ASSIGN_EXTENSION
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
AUXFU_ASSIGN_GROUP (C, M)
MD 22000: $MC_AUXFU_ASSIGN_GROUP
MD 22000: $MC_AUXFU_ASSIGN_GROUP
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
AUXFU_ASSIGN_TYPE (C, M)
MD 22010: $MC_AUXFU_ASSIGN_TYPE
MD 22010: $MC_AUXFU_ASSIGN_TYPE
Units and value ranges
Physical unit:
Data type:
-
TYPE_STRING
Addressing
Line index:
Max. line index:
2
Read access
AUXFU_ASSIGN_VALUE (C, M)
MD 22030: $MC_AUXFU_ASSIGN_VALUE
MD 22030: $MC_AUXFU_ASSIGN_VALUE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Addressing
Line index:
Max. line index:
2
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
139
NC variables
3.2 NC variable descriptions
AUXFU_AT_BLOCK_SEARCH_END (C, M)
MD 22300: $MC_AUX-
FU_AT_BLOCK_SEARCH_END
MD 22300: $MC_AUXFU_AT_BLOCK_SEARCH_END
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
AUXFU_D_SYNC_TYPE (C, M)
MD 22250: $MC_AUXFU_D_SYNC_TYPE
MD 22250: $MC_AUXFU_D_SYNC_TYPE
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
AUXFU_E_SYNC_TYPE (C, M)
MD 22260: $MC_AUXFU_E_SYNC_TYPE
MD 22260: $MC_AUXFU_E_SYNC_TYPE
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
AUXFU_F_SYNC_TYPE (C, M)
MD 22240: $MC_AUXFU_F_SYNC_TYPE
MD 22240: $MC_AUXFU_F_SYNC_TYPE
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
AUXFU_H_SYNC_TYPE (C, M)
MD 22230: $MC_AUXFU_H_SYNC_TYPE
MD 22230: $MC_AUXFU_H_SYNC_TYPE
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
AUXFU_M_SYNC_TYPE (C, M)
MD 22200: $MC_AUXFU_M_SYNC_TYPE
MD 22200: $MC_AUXFU_M_SYNC_TYPE
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
NC variables
140
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
AUXFU_S_SYNC_TYPE (C, M)
MD 22210: $MC_AUXFU_S_SYNC_TYPE
MD 22210: $MC_AUXFU_S_SYNC_TYPE
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
AUXFU_T_SYNC_TYPE (C, M)
MD 22220: $MC_AUXFU_T_SYNC_TYPE
MD 22220: $MC_AUXFU_T_SYNC_TYPE
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
AXCONF_CHANAX_NAME_TAB (C, M)
MD 20080: $MC_AXCONF_CHA-
NAX_NAME_TAB
MD 20080: $MC_AXCONF_CHANAX_NAME_TAB
Units and value ranges
Physical unit:
Data type:
-
TYPE_STRING
Addressing
Line index:
Max. line index:
2
Read access
AXCONF_GEOAX_ASSIGN_TAB (C, M)
MD 20050: $MC_AXCONF_GEOAX_AS-
SIGN_TAB
MD 20050: $MC_AXCONF_GEOAX_ASSIGN_TAB
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
AXCONF_GEOAX_NAME_TAB (C, M)
MD 20060: $MC_AXCONF_GEO-
AX_NAME_TAB
MD 20060: $MC_AXCONF_GEOAX_NAME_TAB
Units and value ranges
Physical unit:
Data type:
-
TYPE_STRING
Addressing
Line index:
Max. line index:
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
141
NC variables
3.2 NC variable descriptions
AXCONF_GEOAX_NAME_TAB (C, M)
MD 20060: $MC_AXCONF_GEO-
AX_NAME_TAB
2
Read access
AXCONF_MACHAX_USED (C, M)
MD 20070: $MC_AXCONF_MA-
CHAX_USED
MD 20070: $MC_AXCONF_MACHAX_USED
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
CIRCLE_ERROR_CONST (C, M)
MD 21000: $MC_CIRCLE_ERROR_CONST
MD 21000: $MC_CIRCLE_ERROR_CONST
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
CIRCLE_ERROR_FACTOR (C, M)
MD 21010: $MC_CIRCLE_ERROR_FACTOR
MD 21010: $MC_CIRCLE_ERROR_FACTOR
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
COLLECT_TOOL_CHANGE (C, M)
MD 20128: $MC_COL-
LECT_TOOL_CHANGE
MD 20128: $MC_COLLECT_TOOL_CHANGE
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
COMPRESS_BLOCK_PATH_LIMIT (C, M)
MD 20170: $MC_COM-
PRESS_BLOCK_PATH_LIMIT
MD 20170: $MC_COMPRESS_BLOCK_PATH_LIMIT
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
NC variables
142
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
COMPRESS_VELO_TOL (C, M)
MD 20172: $MC_COMPRESS_VELO_TOL
MD 20172: $MC_COMPRESS_VELO_TOL
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
CONST_VELO_MIN_TIME (C, M)
MD 20500: $MC_CONST_VELO_MIN_TIME
MD 20500: $MC_CONST_VELO_MIN_TIME
Units and value ranges
Physical unit:
Data type:
s, user defined
TYPE_DOUBLE
Read access
CONTOUR_ASSIGN_FASTOUT (C, M)
MD 21070: $MC_CONTOUR_ASSIGN_FAS-
TOUT
MD 21070: $MC_CONTOUR_ASSIGN_FASTOUT
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
CONTOUR_TUNNEL_REACTION (C, M)
MD 21060: $MC_CONTOUR_TUNNEL_RE-
ACTION
MD 21060: $MC_CONTOUR_TUNNEL_REACTION
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
CONTOUR_TUNNEL_TOL (C, M)
MD 21050: $MC_CONTOUR_TUNNEL_TOL
MD 21050: $MC_CONTOUR_TUNNEL_TOL
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
COUPLE_AXIS_1 (C, M)
MD 21300: $MC_COUPLE_AXIS_1
MD 21300: $MC_COUPLE_AXIS_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
143
NC variables
3.2 NC variable descriptions
COUPLE_AXIS_1 (C, M)
MD 21300: $MC_COUPLE_AXIS_1
2
Read access
COUPLE_BLOCK_CHANGE_CTRL_1 (C, M)
MD 21320: $MC_COU-
PLE_BLOCK_CHANGE_CTRL_1
MD 21320: $MC_COUPLE_BLOCK_CHANGE_CTRL_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
COUPLE_IS_WRITE_PROT_1 (C, M)
MD 21340: $MC_COUPLE_IS_WRI-
TE_PROT_1
MD 21340: $MC_COUPLE_IS_WRITE_PROT_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
COUPLE_RESET_MODE_1 (C, M)
MD 21330: $MC_COUPLE_RESET_MO-
DE_1
MD 21330: $MC_COUPLE_RESET_MODE_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
COUPLING_MODE_1 (C, M)
MD 21310: $MC_COUPLING_MODE_1
MD 21310: $MC_COUPLING_MODE_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
CPREC_WITH_FFW (C, M)
MD 20470: $MC_CPREC_WITH_FFW
MD 20470: $MC_CPREC_WITH_FFW
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
CUBIC_SPLINE_BLOCKS (C, M)
MD 20160: $MC_CUBIC_SPLINE_BLOCKS
MD 20160: $MC_CUBIC_SPLINE_BLOCKS
NC variables
144
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
CUBIC_SPLINE_BLOCKS (C, M)
MD 20160: $MC_CUBIC_SPLINE_BLOCKS
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
CUTCOM_CORNER_LIMIT (C, M)
MD 20210: $MC_CUTCOM_CORNER_LI-
MIT
MD 20210: $MC_CUTCOM_CORNER_LIMIT
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
CUTCOM_CURVE_INSERT_LIMIT (C, M)
MD 20230: $MC_CUTCOM_CURVE_IN-
SERT_LIMIT
MD 20230: $MC_CUTCOM_CURVE_INSERT_LIMIT
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
CUTCOM_INTERS_POLY_ENABLE (C, M)
MD 20256: $MC_CUTCOM_INTERS_PO-
LY_ENABLE
MD 20256: $MC_CUTCOM_INTERS_POLY_ENABLE
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
CUTCOM_MAXNUM_CHECK_BLOCKS (C, M)
MD 20240: $MC_CUTCOM_MAX-
NUM_CHECK_BLOCKS
MD 20240: $MC_CUTCOM_MAXNUM_CHECK_BLOCKS
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
CUTCOM_MAXNUM_SUPPR_BLOCKS (C, M)
MD 20252: $MC_CUTCOM_MAX-
NUM_SUPPR_BLOCKS
MD 20252: $MC_CUTCOM_MAXNUM_SUPPR_BLOCKS
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
145
NC variables
3.2 NC variable descriptions
CUTCOM_MAX_DISC (C, M)
MD 20220: $MC_CUTCOM_MAX_DISC
MD 20220: $MC_CUTCOM_MAX_DISC
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
CUTCOM_PARALLEL_ORI_LIMIT (C, M)
MD 21080: $MC_CUTCOM_PARAL-
LEL_ORI_LIMIT
MD 21080: $MC_CUTCOM_PARALLEL_ORI_LIMIT
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
CUTCOM_PLANE_ORI_LIMIT (C, M)
MD 21082: $MC_CUTCOM_PLANE_ORI_LI-
MIT
MD 21082: $MC_CUTCOM_PLANE_ORI_LIMIT
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
CUTCOM_PLANE_PATH_LIMIT (C, M)
MD 21084: $MC_CUTCOM_PLA-
NE_PATH_LIMIT
MD 21084: $MC_CUTCOM_PLANE_PATH_LIMIT
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
CUTTING_EDGE_DEFAULT (C, M)
MD 20270: $MC_CUTTING_EDGE_DE-
FAULT
MD 20270: $MC_CUTTING_EDGE_DEFAULT
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
NC variables
146
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
CUTTING_EDGE_RESET_VALUE (C, M)
MD 20130: $MC_CUTTING_EDGE_RE-
SET_VALUE
Cutting edge length offset during run-up
Specifies the selection of the cutting edge (D number) for the tool length offset. The following dependencies exist:
o With run-up, reset or part program end via the setting of MD20110 $MC_RESET_MODE_MASK
o With part program start via MD20112 $MC_START_MODE_MASK
The last tool offset, usually the tool on the spindle, remains active if bits 0 and 6 are set in MD20110 $MC_RESET_MODE_MASK.
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
DIAMETER_AX_DEF (C, M)
MD 20100: $MC_DIAMETER_AX_DEF
MD 20100: $MC_DIAMETER_AX_DEF
Units and value ranges
Physical unit:
Data type:
-
TYPE_STRING
Read access
DIG_A_MAX (C, M)
MD 21460: $MC_DIG_A_MAX
MD 21460: $MC_DIG_A_MAX
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
DIG_A_MAX_MOVE (C, M)
MD 21462: $MC_DIG_A_MAX_MOVE
MD 21462: $MC_DIG_A_MAX_MOVE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
DIG_A_MAX_SCAN (C, M)
MD 21464: $MC_DIG_A_MAX_SCAN
MD 21464: $MC_DIG_A_MAX_SCAN
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
DIG_DELTAPOS (C, M)
MD 21440: $MC_DIG_DELTAPOS
MD 21440: $MC_DIG_DELTAPOS
Units and value ranges
Physical unit:
Data type:
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
147
NC variables
3.2 NC variable descriptions
DIG_DELTAPOS (C, M)
MD 21440: $MC_DIG_DELTAPOS
-
TYPE_DOUBLE
Read access
DIG_L_INKR (C, M)
MD 21424: $MC_DIG_L_INKR
MD 21424: $MC_DIG_L_INKR
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
DIG_L_MIN (C, M)
MD 21430: $MC_DIG_L_MIN
MD 21430: $MC_DIG_L_MIN
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
DIG_L_NORMAL (C, M)
MD 21432: $MC_DIG_L_NORMAL
MD 21432: $MC_DIG_L_NORMAL
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
DIG_L_NOTAUS (C, M)
MD 21434: $MC_DIG_L_NOTAUS
MD 21434: $MC_DIG_L_NOTAUS
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
DIG_L_NOTAUS_EXT (C, M)
MD 21436: $MC_DIG_L_NOTAUS_EXT
MD 21436: $MC_DIG_L_NOTAUS_EXT
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
DIG_L_OFF_Z (C, M)
MD 21422: $MC_DIG_L_OFF_Z
MD 21422: $MC_DIG_L_OFF_Z
NC variables
148
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
DIG_L_OFF_Z (C, M)
MD 21422: $MC_DIG_L_OFF_Z
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
DIG_L_ORDER (C, M)
MD 21420: $MC_DIG_L_ORDER
MD 21420: $MC_DIG_L_ORDER
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
DIG_PROT_VERSION (C, M)
MD 21400: $MC_DIG_PROT_VERSION
MD 21400: $MC_DIG_PROT_VERSION
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
DIG_P_HAND (C, M)
MD 21470: $MC_DIG_P_HAND
MD 21470: $MC_DIG_P_HAND
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
DIG_P_SCAN (C, M)
MD 21472: $MC_DIG_P_SCAN
MD 21472: $MC_DIG_P_SCAN
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
DIG_T_SCAN (C, M)
MD 21474: $MC_DIG_T_SCAN
MD 21474: $MC_DIG_T_SCAN
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
DIG_V_EILGANG (C, M)
MD 21450: $MC_DIG_V_EILGANG
MD 21450: $MC_DIG_V_EILGANG
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
149
NC variables
3.2 NC variable descriptions
DIG_V_EILGANG (C, M)
MD 21450: $MC_DIG_V_EILGANG
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
F_VALUES_ACTIVE_AFTER_RESET (C, M)
MD 22410: $MC_F_VALUES_ACTIVE_AF-
TER_RESET
MD 22410: $MC_F_VALUES_ACTIVE_AFTER_RESET
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
GCODE_GROUPS_TO_PLC (C, M)
MD 22510:
$MC_GCODE_GROUPS_TO_PLC
MD 22510: $MC_GCODE_GROUPS_TO_PLC
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
GCODE_RESET_VALUES (C, M)
MD 20150: $MC_GCODE_RESET_VALUES
MD 20150: $MC_GCODE_RESET_VALUES
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
GEOAX_CHANGE_M_CODE (C, M)
MD 22532: $MC_GEO-
AX_CHANGE_M_CODE
MD 22532: $MC_GEOAX_CHANGE_M_CODE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
GEOAX_CHANGE_RESET (C, M)
MD 20118: $MC_GEOAX_CHANGE_RESET
MD 20118: $MC_GEOAX_CHANGE_RESET
NC variables
150
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
GEOAX_CHANGE_RESET (C, M)
MD 20118: $MC_GEOAX_CHANGE_RESET
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
HANDWH_CHAN_STOP_COND (C, M)
MD 20624:
$MC_HANDWH_CHAN_STOP_COND
MD 20624: $MC_HANDWH_CHAN_STOP_COND
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
HANDWH_GEOAX_MAX_INCR_SIZE (C, M)
MD 20620: $MC_HANDWH_GEO-
AX_MAX_INCR_SIZE
MD 20620: $MC_HANDWH_GEOAX_MAX_INCR_SIZE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
HANDWH_GEOAX_MAX_INCR_VSIZE (C, M)
MD 20622: $MC_HANDWH_GEO-
AX_MAX_INCR_VSIZE
MD 20622: $MC_HANDWH_GEOAX_MAX_INCR_VSIZE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
IGNORE_INHIBIT_ASUP (C, M)
MD 20116: $MC_IGNORE_INHIBIT_ASUP
MD 20116: $MC_IGNORE_INHIBIT_ASUP
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
IGNORE_SINGLEBLOCK_ASUP (C, M)
MD 20117: $MC_IGNORE_SINGLE-
BLOCK_ASUP
MD 20117: $MC_IGNORE_SINGLEBLOCK_ASUP
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
151
NC variables
3.2 NC variable descriptions
LEN_AC_FIFO (C, M)
MD 28264: $MC_LEN_AC_FIFO
MD 28264: $MC_LEN_AC_FIFO
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
LIFTFAST_DIST (C, M)
MD 21200: $MC_LIFTFAST_DIST
MD 21200: $MC_LIFTFAST_DIST
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
LOOKAH_NUM_OVR_POINTS (C, M)
MD 20430: $MC_LOO-
KAH_NUM_OVR_POINTS
MD 20430: $MC_LOOKAH_NUM_OVR_POINTS
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
LOOKAH_OVR_POINTS (C, M)
MD 20440: $MC_LOOKAH_OVR_POINTS
MD 20440: $MC_LOOKAH_OVR_POINTS
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
LOOKAH_RELIEVE_BLOCK_CYCLE (C, M)
MD 20450: $MC_LOOKAH_RELIE-
VE_BLOCK_CYCLE
MD 20450: $MC_LOOKAH_RELIEVE_BLOCK_CYCLE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
LOOKAH_USE_VELO_NEXT_BLOCK (C, M)
MD 20400: $MC_LOOKAH_USE_VE-
LO_NEXT_BLOCK
MD 20400: $MC_LOOKAH_USE_VELO_NEXT_BLOCK
NC variables
152
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
LOOKAH_USE_VELO_NEXT_BLOCK (C, M)
MD 20400: $MC_LOOKAH_USE_VE-
LO_NEXT_BLOCK
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
MAX_LEAD_ANGLE (C, M)
MD 21090: $MC_MAX_LEAD_ANGLE
MD 21090: $MC_MAX_LEAD_ANGLE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
MAX_PATH_JERK (C, M)
MD 20600: $MC_MAX_PATH_JERK
MD 20600: $MC_MAX_PATH_JERK
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
MAX_TILT_ANGLE (C, M)
MD 21092: $MC_MAX_TILT_ANGLE
MD 21092: $MC_MAX_TILT_ANGLE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
MDC_TECHNOLOGY_MODE (C, M)
MD 27800: $MC_MDC_TECHNOLO-
GY_MODE
Alternative name:
TECHNOLOGY_MODE
MD 27800: $MC_MDC_TECHNOLOGY_MODE
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
1
Read access
MDS_CHAN_NAME (C, M)
MD 20000: $MC_MDS_CHAN_NAME
Alternative name:
CHAN_NAME
MD 20000: $MC_MDS_CHAN_NAME
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
153
NC variables
3.2 NC variable descriptions
MDS_CHAN_NAME (C, M)
MD 20000: $MC_MDS_CHAN_NAME
Units and value ranges
Physical unit:
Data type:
-
TYPE_STRING
Addressing
Line index:
Max. line index:
1
Read access
MM_IPO_BUFFER_SIZE (C, M)
MD 28060: $MC_MM_IPO_BUFFER_SIZE
MD 28060: $MC_MM_IPO_BUFFER_SIZE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_IPO_TASK_STACK_SIZE (C, M)
MD 28510:
$MC_MM_IPO_TASK_STACK_SIZE
MD 28510: $MC_MM_IPO_TASK_STACK_SIZE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_LINK_TOA_UNIT (C, M)
MD 28085: $MC_MM_LINK_TOA_UNIT
MD 28085: $MC_MM_LINK_TOA_UNIT
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_LUD_VALUES_MEM (C, M)
MD 28040: $MC_MM_LUD_VALUES_MEM
MD 28040: $MC_MM_LUD_VALUES_MEM
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_MAX_TRACE_DATAPOINTS (C, M)
MD 28180: $MC_MM_MAX_TRACE_DATA-
POINTS
MD 28180: $MC_MM_MAX_TRACE_DATAPOINTS
Units and value ranges
Physical unit:
Data type:
NC variables
154
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
MM_MAX_TRACE_DATAPOINTS (C, M)
MD 28180: $MC_MM_MAX_TRACE_DATA-
POINTS
-
TYPE_DWORD
Read access
MM_NUM_AC_MARKER (C, M)
MD 28256: $MC_MM_NUM_AC_MARKER
MD 28256: $MC_MM_NUM_AC_MARKER
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_NUM_AC_PARAM (C, M)
MD 28254: $MC_MM_NUM_AC_PARAM
MD 28254: $MC_MM_NUM_AC_PARAM
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_NUM_AC_TIMER (C, M)
MD 28258: $MC_MM_NUM_AC_TIMER
MD 28258: $MC_MM_NUM_AC_TIMER
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_NUM_BLOCKS_IN_PREP (C, M)
MD 28070:
$MC_MM_NUM_BLOCKS_IN_PREP
MD 28070: $MC_MM_NUM_BLOCKS_IN_PREP
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_NUM_CC_BLOCK_ELEMENTS (C, M)
MD 28090:
$MC_MM_NUM_CC_BLOCK_ELEMENTS
MD 28090: $MC_MM_NUM_CC_BLOCK_ELEMENTS
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_NUM_CC_BLOCK_USER_MEM (C, M)
MD 28100:
$MC_MM_NUM_CC_BLOCK_USER_MEM
MD 28100: $MC_MM_NUM_CC_BLOCK_USER_MEM
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
155
NC variables
3.2 NC variable descriptions
MM_NUM_CC_BLOCK_USER_MEM (C, M)
MD 28100:
$MC_MM_NUM_CC_BLOCK_USER_MEM
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_NUM_FCTDEF_ELEMENTS (C, M)
MD 28252: $MC_MM_NUM_FCTDEF_ELE-
MENTS
MD 28252: $MC_MM_NUM_FCTDEF_ELEMENTS
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_NUM_LUD_NAMES_TOTAL (C, M)
MD 28020: $MC_MM_NUM_LUD_NA-
MES_TOTAL
MD 28020: $MC_MM_NUM_LUD_NAMES_TOTAL
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_NUM_PROTECT_AREA_ACTIVE (C, M)
MD 28210: $MC_MM_NUM_PRO-
TECT_AREA_ACTIVE
MD 28210: $MC_MM_NUM_PROTECT_AREA_ACTIVE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_NUM_PROTECT_AREA_CHAN (C, M)
MD 28200: $MC_MM_NUM_PRO-
TECT_AREA_CHAN
MD 28200: $MC_MM_NUM_PROTECT_AREA_CHAN
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_NUM_REORG_LUD_MODULES (C, M)
MD 28010: $MC_MM_NUM_RE-
ORG_LUD_MODULES
MD 28010: $MC_MM_NUM_REORG_LUD_MODULES
Units and value ranges
Physical unit:
Data type:
NC variables
156
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
MM_NUM_REORG_LUD_MODULES (C, M)
MD 28010: $MC_MM_NUM_RE-
ORG_LUD_MODULES
-
TYPE_DWORD
Read access
MM_NUM_R_PARAM (C, M)
MD 28050: $MC_MM_NUM_R_PARAM
MD 28050: $MC_MM_NUM_R_PARAM
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_NUM_SYNC_ELEMENTS (C, M)
MD 28250: $MC_MM_NUM_SYNC_ELE-
MENTS
MD 28250: $MC_MM_NUM_SYNC_ELEMENTS
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_NUM_USER_FRAMES (C, M)
MD 28080: $MC_MM_NUM_USER_FRA-
MES
MD 28080: $MC_MM_NUM_USER_FRAMES
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_NUM_VDIVAR_ELEMENTS (C, M)
MD 28150: $MC_MM_NUM_VDIVAR_ELE-
MENTS
MD 28150: $MC_MM_NUM_VDIVAR_ELEMENTS
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_PREP_TASK_STACK_SIZE (C, M)
MD 28500:
$MC_MM_PREP_TASK_STACK_SIZE
MD 28500: $MC_MM_PREP_TASK_STACK_SIZE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
157
NC variables
3.2 NC variable descriptions
MM_REORG_LOG_FILE_MEM (C, M)
MD 28000: $MC_MM_RE-
ORG_LOG_FILE_MEM
MD 28000: $MC_MM_REORG_LOG_FILE_MEM
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MM_TRACE_DATA_FUNCTION (C, M)
MD 22714: $MC_MM_TRACE_DA-
TA_FUNCTION
MD 22714: $MC_MM_TRACE_DATA_FUNCTION
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MODESWITCH_MASK (C, M)
MD 20114: $MC_MODESWITCH_MASK
MD 20114: $MC_MODESWITCH_MASK
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MODE_AC_FIFO (C, M)
MD 28266: $MC_MODE_AC_FIFO
MD 28266: $MC_MODE_AC_FIFO
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
MULTFEED_ASSIGN_FASTIN (C, M)
MD 21220: $MC_MULTFEED_AS-
SIGN_FASTIN
MD 21220: $MC_MULTFEED_ASSIGN_FASTIN
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
MULTFEED_STORE_MASK (C, M)
MD 21230: $MC_MULT-
FEED_STORE_MASK
MD 21230: $MC_MULTFEED_STORE_MASK
Units and value ranges
Physical unit:
Data type:
NC variables
158
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
MULTFEED_STORE_MASK (C, M)
MD 21230: $MC_MULT-
FEED_STORE_MASK
-
TYPE_CHAR
Read access
NIBBLE_PRE_START_TIME (C, M)
MD 26018: $MC_NIBB-
LE_PRE_START_TIME
MD 26018: $MC_NIBBLE_PRE_START_TIME
Units and value ranges
Physical unit:
Data type:
s, user defined
TYPE_DOUBLE
Read access
NIBBLE_PUNCH_CODE (C, M)
MD 26008: $MC_NIBBLE_PUNCH_CODE
MD 26008: $MC_NIBBLE_PUNCH_CODE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Addressing
Line index:
Max. line index:
2
Read access
NIBBLE_PUNCH_INMASK (C, M)
MD 26006: $MC_NIBBLE_PUNCH_INMASK
MD 26006: $MC_NIBBLE_PUNCH_INMASK
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
NIBBLE_PUNCH_OUTMASK (C, M)
MD 26004: $MC_NIBBLE_PUNCH_OUT-
MASK
Mask for fast output bits
The variable defines a signal that triggers the stroke of the stamp in the punching process.
o Bit[0] defines the output bit for the "Trigger stroke" signal
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
159
NC variables
3.2 NC variable descriptions
NIBBLE_SIGNAL_CHECK (C, M)
MD 26020: $MC_NIBBLE_SIGNAL_CHECK
MD 26020: $MC_NIBBLE_SIGNAL_CHECK
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
NUM_AC_FIFO (C, M)
MD 28260: $MC_NUM_AC_FIFO
MD 28260: $MC_NUM_AC_FIFO
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
ONLINE_CUTCOM_ENABLE (C, M)
MD 20254: $MC_ONLINE_CUT-
COM_ENABLE
MD 20254: $MC_ONLINE_CUTCOM_ENABLE
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
ORIENTATION_IS_EULER (C, M)
MD 21100: $MC_ORIENTATION_IS_EULER
MD 21100: $MC_ORIENTATION_IS_EULER
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
PATH_IPO_IS_ON_TCP (C, M)
MD 20260: $MC_PATH_IPO_IS_ON_TCP
MD 20260: $MC_PATH_IPO_IS_ON_TCP
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
PUNCHNIB_ACTIVATION (C, M)
MD 26012: $MC_PUNCHNIB_ACTIVATION
MD 26012: $MC_PUNCHNIB_ACTIVATION
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
NC variables
160
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
PUNCHNIB_ASSIGN_FASTIN (C, M)
MD 26000: $MC_PUNCHNIB_AS-
SIGN_FASTIN
MD 26000: $MC_PUNCHNIB_ASSIGN_FASTIN
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
PUNCHNIB_ASSIGN_FASTOUT (C, M)
MD 26002: $MC_PUNCHNIB_AS-
SIGN_FASTOUT
MD 26002: $MC_PUNCHNIB_ASSIGN_FASTOUT
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
PUNCHNIB_AXIS_MASK (C, M)
MD 26010: $MC_PUNCHNIB_AXIS_MASK
MD 26010: $MC_PUNCHNIB_AXIS_MASK
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
PUNCH_PARTITION_TYPE (C, M)
MD 26016: $MC_PUNCH_PARTITION_TY-
PE
MD 26016: $MC_PUNCH_PARTITION_TYPE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
PUNCH_PATH_SPLITTING (C, M)
MD 26014: $MC_PUNCH_PATH_SPLIT-
TING
MD 26014: $MC_PUNCH_PATH_SPLITTING
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
REFP_NC_START_LOCK (C, M)
MD 20700: $MC_REFP_NC_START_LOCK
MD 20700: $MC_REFP_NC_START_LOCK
Units and value ranges
Physical unit:
Data type:
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
161
NC variables
3.2 NC variable descriptions
REFP_NC_START_LOCK (C, M)
MD 20700: $MC_REFP_NC_START_LOCK
-
TYPE_BOOLEAN
Read access
REORG_LOG_LIMIT (C, M)
MD 27900: $MC_REORG_LOG_LIMIT
MD 27900: $MC_REORG_LOG_LIMIT
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
RESET_MODE_MASK (C, M)
MD 20110: $MC_RESET_MODE_MASK
Spec. init. setting of control after Reset/PP end
Specifies the initial setting of the control after run-up and reset/part program end with regard to the G codes (in particular
current plane and settable work offset), tool length offset and transformation by setting the following bits.
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
SETINT_ASSIGN_FASTIN (C, M)
MD 21210: $MC_SETINT_ASSIGN_FASTIN
MD 21210: $MC_SETINT_ASSIGN_FASTIN
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
SPF_END_TO_VDI (C, M)
MD 20800: $MC_SPF_END_TO_VDI
MD 20800: $MC_SPF_END_TO_VDI
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
SPIND_ASSIGN_TAB_ENABLE (C, M)
MD 20092: $MC_SPIND_AS-
SIGN_TAB_ENABLE
MD 20092: $MC_SPIND_ASSIGN_TAB_ENABLE
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
SPIND_DEF_MASTER_SPIND (C, M)
MD 20090: $MC_SPIND_DEF_MAS-
TER_SPIND
MD 20090: $MC_SPIND_DEF_MASTER_SPIND
NC variables
162
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
SPIND_DEF_MASTER_SPIND (C, M)
MD 20090: $MC_SPIND_DEF_MAS-
TER_SPIND
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
SPLINE_FEED_PRECISION (C, M)
MD 20262: $MC_SPLINE_FEED_PRECISI-
ON
MD 20262: $MC_SPLINE_FEED_PRECISION
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
START_AC_FIFO (C, M)
MD 28262: $MC_START_AC_FIFO
MD 28262: $MC_START_AC_FIFO
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
START_MODE_MASK (C, M)
MD 20112: $MC_START_MODE_MASK
MD 20112: $MC_START_MODE_MASK
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
S_VALUES_ACTIVE_AFTER_RESET (C, M)
MD 22400: $MC_S_VALUES_ACTIVE_AF-
TER_RESET
MD 22400: $MC_S_VALUES_ACTIVE_AFTER_RESET
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
THREAD_AUTO_LIFTFASTANGLE (C, M)
MD 20660: $MC_THREAD_AUTO_LIFTFAS-
TANGLE
MD 20660: $MC_THREAD_AUTO_LIFTFASTANGLE
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
163
NC variables
3.2 NC variable descriptions
THREAD_START_IS_HARD (C, M)
MD 20650:
$MC_THREAD_START_IS_HARD
MD 20650: $MC_THREAD_START_IS_HARD
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
TOCARR_CHANGE_M_CODE (C, M)
MD 22530: $MC_TO-
CARR_CHANGE_M_CODE
MD 22530: $MC_TOCARR_CHANGE_M_CODE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TOOL_CARRIER_RESET_VALUE (C, M)
MD 20126: $MC_TOOL_CARRIER_RE-
SET_VALUE
MD 20126: $MC_TOOL_CARRIER_RESET_VALUE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TOOL_CHANGE_MODE (C, M)
MD 22550: $MC_TOOL_CHANGE_MODE
MD 22550: $MC_TOOL_CHANGE_MODE
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
TOOL_CHANGE_M_CODE (C, M)
MD 22560:
$MC_TOOL_CHANGE_M_CODE
MD 22560: $MC_TOOL_CHANGE_M_CODE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TOOL_GRIND_AUTO_TMON (C, M)
MD 20350: $MC_TOOL_GRIND_AU-
TO_TMON
MD 20350: $MC_TOOL_GRIND_AUTO_TMON
Units and value ranges
Physical unit:
Data type:
NC variables
164
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
TOOL_GRIND_AUTO_TMON (C, M)
MD 20350: $MC_TOOL_GRIND_AU-
TO_TMON
-
TYPE_CHAR
Read access
TOOL_MANAGEMENT_MASK (C, M)
MD 20310: $MC_TOOL_MANAGE-
MENT_MASK
MD 20310: $MC_TOOL_MANAGEMENT_MASK
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TOOL_MANAGEMENT_TOOLHOLDER (C, M)
MD 20124: $MC_TOOL_MANAGE-
MENT_TOOLHOLDER
MD 20124: $MC_TOOL_MANAGEMENT_TOOLHOLDER
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TOOL_PARAMETER_DEF_MASK (C, M)
MD 20360: $MC_TOOL_PARAME-
TER_DEF_MASK
MD 20360: $MC_TOOL_PARAMETER_DEF_MASK
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TOOL_PRESEL_RESET_VALUE (C, M)
MD 20121: $MC_TOOL_PRESEL_RE-
SET_VALUE
MD 20121: $MC_TOOL_PRESEL_RESET_VALUE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TOOL_RESET_NAME (C, M)
MD 20122: $MC_TOOL_RESET_NAME
MD 20122: $MC_TOOL_RESET_NAME
Units and value ranges
Physical unit:
Data type:
-
TYPE_STRING
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
165
NC variables
3.2 NC variable descriptions
TOOL_RESET_VALUE (C, M)
MD 20120: $MC_TOOL_RESET_VALUE
MD 20120: $MC_TOOL_RESET_VALUE
Specifies the selection of the tool (T number) for the tool length offset. The following dependencies exist:
o With run-up, reset or part program end via the setting of MD20110 $MC_RESET_MODE_MASK
o With part program start via MD20112 $MC_START_MODE_MASK.
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TOOL_TIME_MONITOR_MASK (C, M)
MD 20320: $MC_TOOL_TIME_MONI-
TOR_MASK
MD 20320: $MC_TOOL_TIME_MONITOR_MASK
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TRAANG_ANGLE_1 (C, M)
MD 24700: $MC_TRAANG_ANGLE_1
MD 24700: $MC_TRAANG_ANGLE_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRAANG_ANGLE_2 (C, M)
MD 24750: $MC_TRAANG_ANGLE_2
MD 24750: $MC_TRAANG_ANGLE_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRAANG_BASE_TOOL_1 (C, M)
MD 24710: $MC_TRAANG_BASE_TOOL_1
MD 24710: $MC_TRAANG_BASE_TOOL_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
NC variables
166
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
TRAANG_BASE_TOOL_2 (C, M)
MD 24760: $MC_TRAANG_BASE_TOOL_2
MD 24760: $MC_TRAANG_BASE_TOOL_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
TRAANG_PARALLEL_ACCEL_RES_1 (C, M)
MD 24721: $MC_TRAANG_PARALLEL_AC-
CEL_RES_1
MD 24721: $MC_TRAANG_PARALLEL_ACCEL_RES_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRAANG_PARALLEL_ACCEL_RES_2 (C, M)
MD 24771: $MC_TRAANG_PARALLEL_AC-
CEL_RES_2
MD 24771: $MC_TRAANG_PARALLEL_ACCEL_RES_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRAANG_PARALLEL_VELO_RES_1 (C, M)
MD 24720: $MC_TRAANG_PARALLEL_VE-
LO_RES_1
MD 24720: $MC_TRAANG_PARALLEL_VELO_RES_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRAANG_PARALLEL_VELO_RES_2 (C, M)
MD 24770: $MC_TRAANG_PARALLEL_VE-
LO_RES_2
MD 24770: $MC_TRAANG_PARALLEL_VELO_RES_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRACE_SCOPE_MASK (C, M)
MD 22708: $MC_TRACE_SCOPE_MASK
MD 22708: $MC_TRACE_SCOPE_MASK
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
167
NC variables
3.2 NC variable descriptions
TRACE_SCOPE_MASK (C, M)
MD 22708: $MC_TRACE_SCOPE_MASK
Units and value ranges
Physical unit:
Data type:
-
TYPE_STRING
Read access
TRACE_STARTTRACE_EVENT (C, M)
MD 22700: $MC_TRACE_STARTTRA-
CE_EVENT
MD 22700: $MC_TRACE_STARTTRACE_EVENT
Units and value ranges
Physical unit:
Data type:
-
TYPE_STRING
Read access
TRACE_STARTTRACE_STEP (C, M)
MD 22702: $MC_TRACE_STARTTRA-
CE_STEP
MD 22702: $MC_TRACE_STARTTRACE_STEP
Units and value ranges
Physical unit:
Data type:
-
TYPE_STRING
Addressing
Line index:
Max. line index:
2
Read access
TRACE_STOPTRACE_EVENT (C, M)
MD 22704: $MC_TRACE_STOPTRA-
CE_EVENT
MD 22704: $MC_TRACE_STOPTRACE_EVENT
Units and value ranges
Physical unit:
Data type:
-
TYPE_STRING
Read access
TRACE_STOPTRACE_STEP (C, M)
MD 22706: $MC_TRACE_STOPTRA-
CE_STEP
MD 22706: $MC_TRACE_STOPTRACE_STEP
Units and value ranges
Physical unit:
Data type:
-
TYPE_STRING
Addressing
Line index:
Max. line index:
2
Read access
NC variables
168
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
TRACE_VARIABLE_INDEX (C, M)
MD 22712: $MC_TRACE_VARIABLE_IN-
DEX
MD 22712: $MC_TRACE_VARIABLE_INDEX
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Addressing
Line index:
Max. line index:
2
Read access
TRACE_VARIABLE_NAME (C, M)
MD 22710: $MC_TRACE_VARIABLE_NAME
MD 22710: $MC_TRACE_VARIABLE_NAME
Units and value ranges
Physical unit:
Data type:
-
TYPE_STRING
Addressing
Line index:
Max. line index:
2
Read access
TRACLG_CONTACT_LOWER_LIMIT (C, M)
MD 21520: $MC_TRACLG_CONTACT_LO-
WER_LIMIT
MD 21520: $MC_TRACLG_CONTACT_LOWER_LIMIT
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRACLG_CONTACT_UPPER_LIMIT (C, M)
MD 21518: $MC_TRACLG_CONTACT_UP-
PER_LIMIT
MD 21518: $MC_TRACLG_CONTACT_UPPER_LIMIT
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRACLG_CTRLSPI_NR (C, M)
MD 21524: $MC_TRACLG_CTRLSPI_NR
MD 21524: $MC_TRACLG_CTRLSPI_NR
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
169
NC variables
3.2 NC variable descriptions
TRACLG_CTRLSPI_VERT_OFFSET (C, M)
MD 21502:
$MC_TRACLG_CTRLSPI_VERT_OFFSET
MD 21502: $MC_TRACLG_CTRLSPI_VERT_OFFSET
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRACLG_G0_IS_SPECIAL (C, M)
MD 21526: $MC_TRACLG_G0_IS_SPECIAL
MD 21526: $MC_TRACLG_G0_IS_SPECIAL
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
TRACLG_GRINDSPI_HOR_OFFSET (C, M)
MD 21501: $MC_TRACLG_GRIND-
SPI_HOR_OFFSET
MD 21501: $MC_TRACLG_GRINDSPI_HOR_OFFSET
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRACLG_GRINDSPI_NR (C, M)
MD 21522: $MC_TRACLG_GRINDSPI_NR
MD 21522: $MC_TRACLG_GRINDSPI_NR
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
TRACLG_GRINDSPI_VERT_OFFSET (C, M)
MD 21500: $MC_TRACLG_GRIND-
SPI_VERT_OFFSET
MD 21500: $MC_TRACLG_GRINDSPI_VERT_OFFSET
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRACLG_HOR_DIR_SUPPORTAX_1 (C, M)
MD 21510: $MC_TRACLG_HOR_DIR_SUP-
PORTAX_1
MD 21510: $MC_TRACLG_HOR_DIR_SUPPORTAX_1
Units and value ranges
Physical unit:
Data type:
NC variables
170
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
TRACLG_HOR_DIR_SUPPORTAX_1 (C, M)
MD 21510: $MC_TRACLG_HOR_DIR_SUP-
PORTAX_1
-
TYPE_DOUBLE
Read access
TRACLG_HOR_DIR_SUPPORTAX_2 (C, M)
MD 21514: $MC_TRACLG_HOR_DIR_SUP-
PORTAX_2
MD 21514: $MC_TRACLG_HOR_DIR_SUPPORTAX_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRACLG_SUPPORT_HOR_OFFSET (C, M)
MD 21506: $MC_TRACLG_SUP-
PORT_HOR_OFFSET
MD 21506: $MC_TRACLG_SUPPORT_HOR_OFFSET
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRACLG_SUPPORT_LEAD_ANGLE (C, M)
MD 21516: $MC_TRACLG_SUP-
PORT_LEAD_ANGLE
MD 21516: $MC_TRACLG_SUPPORT_LEAD_ANGLE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRACLG_SUPPORT_VERT_OFFSET (C, M)
MD 21504: $MC_TRACLG_SUP-
PORT_VERT_OFFSET
MD 21504: $MC_TRACLG_SUPPORT_VERT_OFFSET
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRACLG_VERT_DIR_SUPPORTAX_1 (C, M)
MD 21508: $MC_TRACLG_VERT_DIR_SUP-
PORTAX_1
MD 21508: $MC_TRACLG_VERT_DIR_SUPPORTAX_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
171
NC variables
3.2 NC variable descriptions
TRACLG_VERT_DIR_SUPPORTAX_2 (C, M)
MD 21512: $MC_TRACLG_VERT_DIR_SUP-
PORTAX_2
MD 21512: $MC_TRACLG_VERT_DIR_SUPPORTAX_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRACYL_BASE_TOOL_1 (C, M)
MD 24820: $MC_TRACYL_BASE_TOOL_1
MD 24820: $MC_TRACYL_BASE_TOOL_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
TRACYL_BASE_TOOL_2 (C, M)
MD 24870: $MC_TRACYL_BASE_TOOL_2
MD 24870: $MC_TRACYL_BASE_TOOL_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
TRACYL_ROT_AX_OFFSET_1 (C, M)
MD 24800: $MC_TRACYL_ROT_AX_OFF-
SET_1
MD 24800: $MC_TRACYL_ROT_AX_OFFSET_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRACYL_ROT_AX_OFFSET_2 (C, M)
MD 24850: $MC_TRACYL_ROT_AX_OFF-
SET_2
MD 24850: $MC_TRACYL_ROT_AX_OFFSET_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
NC variables
172
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
TRACYL_ROT_SIGN_IS_PLUS_1 (C, M)
MD 24810: $MC_TRA-
CYL_ROT_SIGN_IS_PLUS_1
MD 24810: $MC_TRACYL_ROT_SIGN_IS_PLUS_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
TRACYL_ROT_SIGN_IS_PLUS_2 (C, M)
MD 24860: $MC_TRA-
CYL_ROT_SIGN_IS_PLUS_2
MD 24860: $MC_TRACYL_ROT_SIGN_IS_PLUS_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
TRAFO5_BASE_TOOL_1 (C, M)
MD 24550: $MC_TRAFO5_BASE_TOOL_1
MD 24550: $MC_TRAFO5_BASE_TOOL_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
TRAFO5_BASE_TOOL_2 (C, M)
MD 24650: $MC_TRAFO5_BASE_TOOL_2
MD 24650: $MC_TRAFO5_BASE_TOOL_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
TRAFO5_JOINT_OFFSET_1 (C, M)
MD 24560: $MC_TRAFO5_JOINT_OFF-
SET_1
MD 24560: $MC_TRAFO5_JOINT_OFFSET_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
173
NC variables
3.2 NC variable descriptions
TRAFO5_JOINT_OFFSET_1 (C, M)
MD 24560: $MC_TRAFO5_JOINT_OFF-
SET_1
2
Read access
TRAFO5_JOINT_OFFSET_2 (C, M)
MD 24660: $MC_TRAFO5_JOINT_OFF-
SET_2
MD 24660: $MC_TRAFO5_JOINT_OFFSET_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
TRAFO5_NON_POLE_LIMIT_1 (C, M)
MD 24530: $MC_TRAFO5_NON_POLE_LI-
MIT_1
MD 24530: $MC_TRAFO5_NON_POLE_LIMIT_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRAFO5_NON_POLE_LIMIT_2 (C, M)
MD 24630: $MC_TRAFO5_NON_POLE_LI-
MIT_2
MD 24630: $MC_TRAFO5_NON_POLE_LIMIT_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRAFO5_NUTATOR_AX_ANGLE_1 (C, M)
MD 24564: $MC_TRAFO5_NUTA-
TOR_AX_ANGLE_1
MD 24564: $MC_TRAFO5_NUTATOR_AX_ANGLE_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRAFO5_NUTATOR_AX_ANGLE_2 (C, M)
MD 24664: $MC_TRAFO5_NUTA-
TOR_AX_ANGLE_2
MD 24664: $MC_TRAFO5_NUTATOR_AX_ANGLE_2
Units and value ranges
Physical unit:
Data type:
NC variables
174
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
TRAFO5_NUTATOR_AX_ANGLE_2 (C, M)
MD 24664: $MC_TRAFO5_NUTA-
TOR_AX_ANGLE_2
-
TYPE_DOUBLE
Read access
TRAFO5_PART_OFFSET_1 (C, M)
MD 24500: $MC_TRAFO5_PART_OFF-
SET_1
MD 24500: $MC_TRAFO5_PART_OFFSET_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
TRAFO5_PART_OFFSET_2 (C, M)
MD 24600: $MC_TRAFO5_PART_OFF-
SET_2
MD 24600: $MC_TRAFO5_PART_OFFSET_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
TRAFO5_POLE_LIMIT_1 (C, M)
MD 24540: $MC_TRAFO5_POLE_LIMIT_1
MD 24540: $MC_TRAFO5_POLE_LIMIT_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRAFO5_POLE_LIMIT_2 (C, M)
MD 24640: $MC_TRAFO5_POLE_LIMIT_2
MD 24640: $MC_TRAFO5_POLE_LIMIT_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRAFO5_ROT_AX_OFFSET_1 (C, M)
MD 24510: $MC_TRAFO5_ROT_AX_OFF-
SET_1
MD 24510: $MC_TRAFO5_ROT_AX_OFFSET_1
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
175
NC variables
3.2 NC variable descriptions
TRAFO5_ROT_AX_OFFSET_1 (C, M)
MD 24510: $MC_TRAFO5_ROT_AX_OFF-
SET_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
TRAFO5_ROT_AX_OFFSET_2 (C, M)
MD 24610: $MC_TRAFO5_ROT_AX_OFF-
SET_2
MD 24610: $MC_TRAFO5_ROT_AX_OFFSET_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
TRAFO5_ROT_SIGN_IS_PLUS_1 (C, M)
MD 24520: $MC_TRA-
FO5_ROT_SIGN_IS_PLUS_1
MD 24520: $MC_TRAFO5_ROT_SIGN_IS_PLUS_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Addressing
Line index:
Max. line index:
2
Read access
TRAFO5_ROT_SIGN_IS_PLUS_2 (C, M)
MD 24620: $MC_TRA-
FO5_ROT_SIGN_IS_PLUS_2
MD 24620: $MC_TRAFO5_ROT_SIGN_IS_PLUS_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Addressing
Line index:
Max. line index:
2
Read access
NC variables
176
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
TRAFO5_TOOL_ROT_AX_OFFSET_1 (C, M)
MD 24562: $MC_TRA-
FO5_TOOL_ROT_AX_OFFSET_1
MD 24562: $MC_TRAFO5_TOOL_ROT_AX_OFFSET_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
TRAFO5_TOOL_ROT_AX_OFFSET_2 (C, M)
MD 24662: $MC_TRA-
FO5_TOOL_ROT_AX_OFFSET_2
MD 24662: $MC_TRAFO5_TOOL_ROT_AX_OFFSET_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_AXES_IN_1 (C, M)
MD 24110: $MC_TRAFO_AXES_IN_1
MD 24110: $MC_TRAFO_AXES_IN_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_AXES_IN_2 (C, M)
MD 24210: $MC_TRAFO_AXES_IN_2
MD 24210: $MC_TRAFO_AXES_IN_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
177
NC variables
3.2 NC variable descriptions
TRAFO_AXES_IN_3 (C, M)
MD 24310: $MC_TRAFO_AXES_IN_3
MD 24310: $MC_TRAFO_AXES_IN_3
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_AXES_IN_4 (C, M)
MD 24410: $MC_TRAFO_AXES_IN_4
MD 24410: $MC_TRAFO_AXES_IN_4
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_AXES_IN_5 (C, M)
MD 24432: $MC_TRAFO_AXES_IN_5
MD 24432: $MC_TRAFO_AXES_IN_5
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_AXES_IN_6 (C, M)
MD 24442: $MC_TRAFO_AXES_IN_6
MD 24442: $MC_TRAFO_AXES_IN_6
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_AXES_IN_7 (C, M)
MD 24452: $MC_TRAFO_AXES_IN_7
MD 24452: $MC_TRAFO_AXES_IN_7
NC variables
178
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
TRAFO_AXES_IN_7 (C, M)
MD 24452: $MC_TRAFO_AXES_IN_7
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_AXES_IN_8 (C, M)
MD 24462: $MC_TRAFO_AXES_IN_8
MD 24462: $MC_TRAFO_AXES_IN_8
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_CHANGE_M_CODE (C, M)
MD 22534: $MC_TRA-
FO_CHANGE_M_CODE
MD 22534: $MC_TRAFO_CHANGE_M_CODE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TRAFO_GEOAX_ASSIGN_TAB_1 (C, M)
MD 24120: $MC_TRAFO_GEOAX_AS-
SIGN_TAB_1
MD 24120: $MC_TRAFO_GEOAX_ASSIGN_TAB_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_GEOAX_ASSIGN_TAB_2 (C, M)
MD 24220: $MC_TRAFO_GEOAX_AS-
SIGN_TAB_2
MD 24220: $MC_TRAFO_GEOAX_ASSIGN_TAB_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
179
NC variables
3.2 NC variable descriptions
TRAFO_GEOAX_ASSIGN_TAB_2 (C, M)
MD 24220: $MC_TRAFO_GEOAX_AS-
SIGN_TAB_2
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_GEOAX_ASSIGN_TAB_3 (C, M)
MD 24320: $MC_TRAFO_GEOAX_AS-
SIGN_TAB_3
MD 24320: $MC_TRAFO_GEOAX_ASSIGN_TAB_3
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_GEOAX_ASSIGN_TAB_4 (C, M)
MD 24420: $MC_TRAFO_GEOAX_AS-
SIGN_TAB_4
MD 24420: $MC_TRAFO_GEOAX_ASSIGN_TAB_4
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_GEOAX_ASSIGN_TAB_5 (C, M)
MD 24434: $MC_TRAFO_GEOAX_AS-
SIGN_TAB_5
MD 24434: $MC_TRAFO_GEOAX_ASSIGN_TAB_5
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_GEOAX_ASSIGN_TAB_6 (C, M)
MD 24444: $MC_TRAFO_GEOAX_AS-
SIGN_TAB_6
MD 24444: $MC_TRAFO_GEOAX_ASSIGN_TAB_6
Units and value ranges
Physical unit:
Data type:
NC variables
180
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
TRAFO_GEOAX_ASSIGN_TAB_6 (C, M)
MD 24444: $MC_TRAFO_GEOAX_AS-
SIGN_TAB_6
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_GEOAX_ASSIGN_TAB_7 (C, M)
MD 24454: $MC_TRAFO_GEOAX_AS-
SIGN_TAB_7
MD 24454: $MC_TRAFO_GEOAX_ASSIGN_TAB_7
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_GEOAX_ASSIGN_TAB_8 (C, M)
MD 24464: $MC_TRAFO_GEOAX_AS-
SIGN_TAB_8
MD 24464: $MC_TRAFO_GEOAX_ASSIGN_TAB_8
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Addressing
Line index:
Max. line index:
2
Read access
TRAFO_RESET_VALUE (C, M)
MD 20140: $MC_TRAFO_RESET_VALUE
MD 20140: $MC_TRAFO_RESET_VALUE
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
TRAFO_TYPE_1 (C, M)
MD 24100: $MC_TRAFO_TYPE_1
MD 24100: $MC_TRAFO_TYPE_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
181
NC variables
3.2 NC variable descriptions
TRAFO_TYPE_2 (C, M)
MD 24200: $MC_TRAFO_TYPE_2
MD 24200: $MC_TRAFO_TYPE_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TRAFO_TYPE_3 (C, M)
MD 24300: $MC_TRAFO_TYPE_3
MD 24300: $MC_TRAFO_TYPE_3
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TRAFO_TYPE_4 (C, M)
MD 24400: $MC_TRAFO_TYPE_4
MD 24400: $MC_TRAFO_TYPE_4
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TRAFO_TYPE_5 (C, M)
MD 24430: $MC_TRAFO_TYPE_5
MD 24430: $MC_TRAFO_TYPE_5
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TRAFO_TYPE_6 (C, M)
MD 24440: $MC_TRAFO_TYPE_6
MD 24440: $MC_TRAFO_TYPE_6
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TRAFO_TYPE_7 (C, M)
MD 24450: $MC_TRAFO_TYPE_7
MD 24450: $MC_TRAFO_TYPE_7
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
NC variables
182
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
TRAFO_TYPE_8 (C, M)
MD 24460: $MC_TRAFO_TYPE_8
MD 24460: $MC_TRAFO_TYPE_8
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
TRANSMIT_BASE_TOOL_1 (C, M)
MD 24920: $MC_TRANSMIT_BA-
SE_TOOL_1
MD 24920: $MC_TRANSMIT_BASE_TOOL_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
TRANSMIT_BASE_TOOL_2 (C, M)
MD 24970: $MC_TRANSMIT_BA-
SE_TOOL_2
MD 24970: $MC_TRANSMIT_BASE_TOOL_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
2
Read access
TRANSMIT_POLE_SIDE_FIX_1 (C, M)
MD 24911: $MC_TRANSMIT_POLE_SI-
DE_FIX_1
MD 24911: $MC_TRANSMIT_POLE_SIDE_FIX_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
TRANSMIT_POLE_SIDE_FIX_2 (C, M)
MD 24961: $MC_TRANSMIT_POLE_SI-
DE_FIX_2
MD 24961: $MC_TRANSMIT_POLE_SIDE_FIX_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_CHAR
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
183
NC variables
3.2 NC variable descriptions
TRANSMIT_ROT_AX_OFFSET_1 (C, M)
MD 24900: $MC_TRANS-
MIT_ROT_AX_OFFSET_1
MD 24900: $MC_TRANSMIT_ROT_AX_OFFSET_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRANSMIT_ROT_AX_OFFSET_2 (C, M)
MD 24950: $MC_TRANS-
MIT_ROT_AX_OFFSET_2
MD 24950: $MC_TRANSMIT_ROT_AX_OFFSET_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access
TRANSMIT_ROT_SIGN_IS_PLUS_1 (C, M)
MD 24910: $MC_TRANS-
MIT_ROT_SIGN_IS_PLUS_1
MD 24910: $MC_TRANSMIT_ROT_SIGN_IS_PLUS_1
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
TRANSMIT_ROT_SIGN_IS_PLUS_2 (C, M)
MD 24960: $MC_TRANS-
MIT_ROT_SIGN_IS_PLUS_2
MD 24960: $MC_TRANSMIT_ROT_SIGN_IS_PLUS_2
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
WORKAREA_WITH_TOOL_RADIUS (C, M)
MD 21020: $MC_WORKA-
REA_WITH_TOOL_RADIUS
MD 21020: $MC_WORKAREA_WITH_TOOL_RADIUS
Units and value ranges
Physical unit:
Data type:
-
TYPE_BOOLEAN
Read access
X_AXIS_IN_OLD_X_Z_PLANE (C, M)
MD 21110:
$MC_X_AXIS_IN_OLD_X_Z_PLANE
MD 21110: $MC_X_AXIS_IN_OLD_X_Z_PLANE
Units and value ranges
Physical unit:
Data type:
NC variables
184
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
X_AXIS_IN_OLD_X_Z_PLANE (C, M)
MD 21110:
$MC_X_AXIS_IN_OLD_X_Z_PLANE
-
TYPE_BOOLEAN
Read access
MM_ABSBLOCK (C, M)
MD 28400: $MC_MM_ABSBLOCK
MD 28400: $MC_MM_ABSBLOCK
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Addressing
Line index:
Max. line index:
1
Read access
AUXFU_ASSOC_M1_VALUE (C, M)
MD 22256: $MC_AUXFU_ASSOC_M1_VA-
LUE
MD 22256: $MC_AUXFU_ASSOC_M1_VALUE
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Addressing
Line index:
Max. line index:
1
Read access and write access
MM_SYSTEM_DATAFRAME_MASK (C, M)
MD 28083: $MC_MM_SYSTEM_DATAFRA-
ME_MASK
MD 28083: $MC_MM_SYSTEM_DATAFRAME_MASK
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Addressing
Line index:
Max. line index:
1
Read access
MM_PROTOC_NUM_ETP_STD_TYP (C, M)
MD 28302: $MC_MM_PRO-
TOC_NUM_ETP_STD_TYP
MD 28302: $MC_MM_PROTOC_NUM_ETP_STD_TYP
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Addressing
Line index:
Max. line index:
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
185
NC variables
3.2 NC variable descriptions
MM_PROTOC_NUM_ETP_STD_TYP (C, M)
MD 28302: $MC_MM_PRO-
TOC_NUM_ETP_STD_TYP
10
Read access and write access
3.2.3.14
NIB: Nibbling data
OEM-MMC: LinkItem /Channel/Nibbling/...
The module NIB contains technology-specific data for nibbling.
actPunchRate (C, NIB)
N4
Strokes per minute
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Validity:
From NCK version 3.6
Read access
automCutSegment (C, NIB)
N4
Automatic block division
Identifier that indicates which type of automatic block division is active. The division is specified by the commands 'SPP' and 'SPN'
in the part program.
Return value
0 = no block division
1 = number of segments per block ('SNP')
2 = segments of fixed length ('SPP')
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Validity:
From NCK version 3.6
Read access
numStrokes (C, NIB)
N4
Number of strokes
Number of strokes when the instruction 'SPN' divides the block into segments (variable 'automCutSegment' = 1).
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
NC variables