NC variables
3.2 NC variable descriptions
numStrokes (C, NIB)
N4
1
Validity:
From NCK version 3.6
Read access
partDistance (C, NIB)
N4
Length of the path between punches
If the block has been divided in segments with the instruction 'SPP' (variable 'automCutSegment' = 2) the variable specifies the
length of the path between the punches.
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Validity:
From NCK version 3.6
Read access
punchActive (C, NIB)
N4
Punching or nibbling active
Identification of punching or nibbling active. The part program turns off/on punching and nibbling with 'SPOF', 'SON' and 'PON'.
Rapid punching and nibbling are turned on/off with 'SONS' and 'PONS'.
The variable 'punchActive' specified the present state.
Return value
0 = inactive
1 = punching active
2 = nibbling active
3 = rapid punching active
4 = rapid nibbling active
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Validity:
From NCK version 3.6
Read access
punchDelayActive (C, NIB)
N4
Punching with delay active
Identifier that indicates whether punching with delay is active. The part program can turn on/off the delay with the instructions
'PDELAYON' and 'PDELAYOF'. The variable 'PunchDelayActive' indicates the present state.
Return value
0 = inactive
1 = active
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
187
NC variables
3.2 NC variable descriptions
punchDelayActive (C, NIB)
N4
Addressing
Line index:
Max. line index:
1
Validity:
From NCK version 3.6
Read access
punchDelayTime (C, NIB)
SD 42400: PUNCH_DWELL_TIME
N4
Punching delay time
Units and value ranges
Physical unit:
Data type:
ms
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Validity:
From NCK version 3.6
Read access
strokeNr (C, NIB)
Current stroke number
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Validity:
From NCK version 3.6
Read access
3.2.3.15
O: Internal
OEM-MMC: LinkItem /Channel/Drive/...
C-O
LOOKAH_NUM_CHECKED_BLOCKS (C, O)
MD 29000: $OC_LOOKAH_NUM_CHE-
CKED_BLOCKS
MD 29000: $OC_LOOKAH_NUM_CHECKED_BLOCKS
Units and value ranges
Physical unit:
Data type:
-
TYPE_DWORD
Read access
NC variables
188
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
3.2.3.16
PA: Protection zones
OEM-MMC: LinkItem /Channel/ProtectedArea/...
Up to 10 protection zones can be defined. Each protection zone is described by a polygon function consisting of up
to 10 elements. The maximum permissible number of protection zones is specified in "$$numProtArea" in the
module Y in area C. The maximum permissible number of polygon definition elements is specified in "$$numCon-
tourInProtArea" in module Y in area C. Module PA contains the individual coordinates of the polygon elements. The
protection zones are addressed via the variable indices.
The classification as NCK or channel-specific protection zone does not affect the protection zone monitoring func-
tion but simply indicates the area in which the protection zone is registered.
The physical unit actually used for length quantities is defined in "$$/C/SGA/extUnit" in module SGA in area C.
MDD_PA_CENT_ABS_0 (C, PA)
$SC_PA_CENT_ABS[x,0] x = Number pro-
A3
tection zone
Abscissa arc centre of 1st contour element
Absolute abscissa value of arc centre of 1st contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ABS_1 (C, PA)
$SC_PA_CENT_ABS[x,1] x = Number pro-
A3
tection zone
Abscissa arc centre of 2nd contour element
Absolute abscissa value of arc centre of 2nd contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ABS_2 (C, PA)
$SC_PA_CENT_ABS[x,2] x = Number pro-
A3
tection zone
Abscissa arc centre of 3rd contour element
Absolute abscissa value of arc centre of 3rd contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
189
NC variables
3.2 NC variable descriptions
MDD_PA_CENT_ABS_2 (C, PA)
$SC_PA_CENT_ABS[x,2] x = Number pro-
A3
tection zone
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ABS_3 (C, PA)
$SC_PA_CENT_ABS[x,3] x = Number pro-
A3
tection zone
Abscissa arc centre of 4th contour element
Absolute abscissa value of arc centre of 4th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ABS_4 (C, PA)
$SC_PA_CENT_ABS[x,4] x = Number pro-
A3
tection zone
Abscissa arc centre of 5th contour element
Absolute abscissa value of arc centre of 5th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ABS_5 (C, PA)
$SC_PA_CENT_ABS[x,5] x = Number pro-
A3
tection zone
Abscissa arc centre of 6th contour element
Absolute abscissa value of arc centre of 6th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
NC variables
190
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
MDD_PA_CENT_ABS_6 (C, PA)
$SC_PA_CENT_ABS[x,6] x = Number pro-
A3
tection zone
Abscissa arc centre of 7th contour element
Absolute abscissa value of arc centre of 7th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ABS_7 (C, PA)
$SC_PA_CENT_ABS[x,7] x = Number pro-
A3
tection zone
Abscissa arc centre of 8th contour element
Absolute abscissa value of arc centre of 8th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ABS_8 (C, PA)
$SC_PA_CENT_ABS[x,8] x = Number pro-
A3
tection zone
Abscissa arc centre of 9th contour element
Absolute abscissa value of arc centre of 9th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ABS_9 (C, PA)
$SC_PA_CENT_ABS[x,9] x = Number pro-
A3
tection zone
Abscissa arc centre of 10th contour element
Absolute abscissa value of arc centre of 10th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
191
NC variables
3.2 NC variable descriptions
MDD_PA_CENT_ABS_9 (C, PA)
$SC_PA_CENT_ABS[x,9] x = Number pro-
A3
tection zone
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ORD_0 (C, PA)
$SC_PA_CENT_ORD[x,0] x = Number pro-
A3
tection zone
Ordinate arc centre of 1st contour element
Absolute ordinate value of arc centre of 1st contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ORD_1 (C, PA)
$SC_PA_CENT_ORD[x,1] x = Number pro-
A3
tection zone
Ordinate arc centre of 2nd contour element
Absolute ordinate value of arc centre of 2nd contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ORD_2 (C, PA)
$SC_PA_CENT_ORD[x,2] x = Number pro-
A3
tection zone
Odinate arc centre of 3rd contour element
Absolute ordinate value of arc centre of 3rd contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
NC variables
192
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
MDD_PA_CENT_ORD_3 (C, PA)
$SC_PA_CENT_ORD[x,3] x = Number pro-
A3
tection zone
Ordinate arc centre of 4th contour element
Absolute ordinate value of arc centre of 4th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ORD_4 (C, PA)
$SC_PA_CENT_ORD[x,4] x = Number pro-
A3
tection zone
Ordinate arc centre of 5th contour element
Absolute ordinate value of arc centre of 5th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ORD_5 (C, PA)
$SC_PA_CENT_ORD[x,5] x = Number pro-
A3
tection zone
Ordinate arc centre of 6th contour element
Absolute ordinate value of arc centre of 6th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ORD_6 (C, PA)
$SC_PA_CENT_ORD[x,6] x = Number pro-
A3
tection zone
Ordinate arc centre of 7th contour element
Absolute ordinate value of arc centre of 7th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
193
NC variables
3.2 NC variable descriptions
MDD_PA_CENT_ORD_6 (C, PA)
$SC_PA_CENT_ORD[x,6] x = Number pro-
A3
tection zone
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ORD_7 (C, PA)
$SC_PA_CENT_ORD[x,7] x = Number pro-
A3
tection zone
Ordinate arc centre of 8th contour element
Absolute ordinate value of arc centre of 8th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ORD_8 (C, PA)
$SC_PA_CENT_ORD[x,8] x = Number pro-
A3
tection zone
Ordinate arc centre of 9th contour element
Absolute ordinate value of arc centre of 9th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CENT_ORD_9 (C, PA)
$SC_PA_CENT_ORD[x,9] x = Number pro-
A3
tection zone
Ordinate arc centre of 10th contour element
Absolute ordinate value of arc centre of 10th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
NC variables
194
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
MDD_PA_CONT_ABS_0 (C, PA)
$SC_PA_CONT_ABS[x,0] x = Number pro-
A3
tection zone
Abscissa end point of 1st contour element
Absolute abscissa value of end point of 1st contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ABS_1 (C, PA)
$SC_PA_CONT_ABS[x,1] x = Number pro-
A3
tection zone
Abscissa end point of 2nd contour element
Absolute abscissa value of end point of 2nd contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ABS_2 (C, PA)
$SC_PA_CONT_ABS[x,2] x = Number pro-
A3
tection zone
Abscissa end point of 3rd contour element
Absolute abscissa value of end point of 3rd contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ABS_3 (C, PA)
$SC_PA_CONT_ABS[x,3] x = Number pro-
A3
tection zone
Abscissa end point of 4th contour element
Absolute abscissa value of end point of 4th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
195
NC variables
3.2 NC variable descriptions
MDD_PA_CONT_ABS_3 (C, PA)
$SC_PA_CONT_ABS[x,3] x = Number pro-
A3
tection zone
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ABS_4 (C, PA)
$SC_PA_CONT_ABS[x,4] x = Number pro-
A3
tection zone
Abscissa end point of 5th contour element
Absolute abscissa value of end point of 5th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ABS_5 (C, PA)
$SC_PA_CONT_ABS[x,5] x = Number pro-
A3
tection zone
Abscissa end point of 6th contour element
Absolute abscissa value of end point of 6th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ABS_6 (C, PA)
$SC_PA_CONT_ABS[x,6] x = Number pro-
A3
tection zone
Abscissa end point of 7th contour element
Absolute abscissa value of end point of 7th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
NC variables
196
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
MDD_PA_CONT_ABS_7 (C, PA)
$SC_PA_CONT_ABS[x,7] x = Number pro-
A3
tection zone
Abscissa end point of 8th contour element
Absolute abscissa value of end point of 8th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ABS_8 (C, PA)
$SC_PA_CONT_ABS[x,8] x = Number pro-
A3
tection zone
Abscissa end point of 9th contour element
Absolute abscissa value of end point of 9th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ABS_9 (C, PA)
$SC_PA_CONT_ABS[x,9] x = Number pro-
A3
tection zone
Abscissa end point of 10th contour element
Absolute abscissa value of end point of 10th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ORD_0 (C, PA)
$SC_PA_CONT_ORD[x,0] x = Number pro-
A3
tection zone
Ordinate end point of 1st contour element
Absolute ordinate value of end point of 1st contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
197
NC variables
3.2 NC variable descriptions
MDD_PA_CONT_ORD_0 (C, PA)
$SC_PA_CONT_ORD[x,0] x = Number pro-
A3
tection zone
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ORD_1 (C, PA)
$SC_PA_CONT_ORD[x,1] x = Number pro-
A3
tection zone
Ordinate end point of 2nd contour element
Absolute ordinate value of end point of 2nd contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ORD_2 (C, PA)
$SC_PA_CONT_ORD[x,2] x = Number pro-
A3
tection zone
Odinate end point of 3rd contour element
Absolute ordinate value of end point of 3rd contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ORD_3 (C, PA)
$SC_PA_CONT_ORD[x,3] x = Number pro-
A3
tection zone
Ordinate end point of 4th contour element
Absolute ordinate value of end point of 4th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
NC variables
198
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
MDD_PA_CONT_ORD_4 (C, PA)
$SC_PA_CONT_ORD[x,4] x = Number pro-
A3
tection zone
Ordinate end point of 5th contour element
Absolute ordinate value of end point of 5th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ORD_5 (C, PA)
$SC_PA_CONT_ORD[x,5] x = Number pro-
A3
tection zone
Ordinate end point of 6th contour element
Absolute ordinate value of end point of 6th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ORD_6 (C, PA)
$SC_PA_CONT_ORD[x,6] x = Number pro-
A3
tection zone
Ordinate end point of 7th contour element
Absolute ordinate value of end point of 7th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ORD_7 (C, PA)
$SC_PA_CONT_ORD[x,7] x = Number pro-
A3
tection zone
Ordinate end point of 8th contour element
Absolute ordinate value of end point of 8th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
199
NC variables
3.2 NC variable descriptions
MDD_PA_CONT_ORD_7 (C, PA)
$SC_PA_CONT_ORD[x,7] x = Number pro-
A3
tection zone
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ORD_8 (C, PA)
$SC_PA_CONT_ORD[x,8] x = Number pro-
A3
tection zone
Ordinate end point of 9th contour element
Absolute ordinate value of end point of 9th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_CONT_ORD_9 (C, PA)
$SC_PA_CONT_ORD[x,9] x = Number pro-
A3
tection zone
Ordinate end point of 10th contour element
Absolute ordinate value of end point of 10th contour element
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDD_PA_MINUS_LIM (C, PA)
$SC_PA_MINUS_LIM[x] x = Number pro-
A3
tection zone
Lower limit of protection zone, applicate
Limitation in the minus direction of the protection zone in the axis that is perpendicular to the polygon definition (applicate)
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
NC variables
200
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
MDD_PA_PLUS_LIM (C, PA)
$SC_PA_PLUS_LIM[x] x = Number protec-
A3
tion zone
Upper boundary of protection zone, applicate
Limitation of the protection zone in the plus direction of the axis that is perpendicular to the polygon definition (applicate)
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDU_PA_ACTIV_IMMED (C, PA)
$SC_PA_ACTIV_IMMED[x] x = Number
A3
protection zone
Active immediately after referencing
Code for "active immediately after referencing", i.e. the protection zone is active as soon as the control has been started up and
the axes have been referenced
Return value
0 = protection zone is not active immediately
1 = protection zone is active immediately
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDU_PA_CONT_NUM (C, PA)
$SC_PA_CONT_NUM[x] x = Number pro-
A3
tection zone
Number of valid contour elements
Units and value ranges
Physical unit:
Data type:
Minimum value:
Maximum value:
-
TYPE_UWORD
0
$$numContourInProtArea
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDU_PA_CONT_TYP_0 (C, PA)
$SC_PA_CONT_TYP[x,0] x = Number pro-
A3
tection zone
Contour type of 1st contour element
Return value
0 = G1
1 = G2
2 = G3
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
201
NC variables
3.2 NC variable descriptions
MDU_PA_CONT_TYP_0 (C, PA)
$SC_PA_CONT_TYP[x,0] x = Number pro-
A3
tection zone
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDU_PA_CONT_TYP_1 (C, PA)
$SC_PA_CONT_TYP[x,1] x = Number pro-
A3
tection zone
Contour type of 2nd contour element
Return value
0 = G1
1 = G2
2 = G3
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDU_PA_CONT_TYP_2 (C, PA)
$SC_PA_CONT_TYP[x,2] x = Number pro-
A3
tection zone
Contour type of 3rd contour element
Return value
0 = G1
1 = G2
2 = G3
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDU_PA_CONT_TYP_3 (C, PA)
$SC_PA_CONT_TYP[x,3] x = Number pro-
A3
tection zone
Contour type of 4th contour element
Return value
0 = G1
1 = G2
2 = G3
NC variables
202
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
MDU_PA_CONT_TYP_3 (C, PA)
$SC_PA_CONT_TYP[x,3] x = Number pro-
A3
tection zone
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDU_PA_CONT_TYP_4 (C, PA)
$SC_PA_CONT_TYP[x,4] x = Number pro-
A3
tection zone
Contour type of 5th contour element
Return value
0 = G1
1 = G2
2 = G3
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDU_PA_CONT_TYP_5 (C, PA)
$SC_PA_CONT_TYP[x,5] x = Number pro-
A3
tection zone
Contour type of 6th contour element
Return value
0 = G1
1 = G2
2 = G3
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDU_PA_CONT_TYP_6 (C, PA)
$SC_PA_CONT_TYP[x,6] x = Number pro-
A3
tection zone
Contour type of 7th contour element
Return value
0 = G1
1 = G2
2 = G3
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
203
NC variables
3.2 NC variable descriptions
MDU_PA_CONT_TYP_6 (C, PA)
$SC_PA_CONT_TYP[x,6] x = Number pro-
A3
tection zone
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDU_PA_CONT_TYP_7 (C, PA)
$SC_PA_CONT_TYP[x,7] x = Number pro-
A3
tection zone
Contour type of 8th contour element
Return value
0 = G1
1 = G2
2 = G3
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDU_PA_CONT_TYP_8 (C, PA)
$SC_PA_CONT_TYP[x,8] x = Number pro-
A3
tection zone
Contour type of 9th contour element
Return value
0 = G1
1 = G2
2 = G3
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDU_PA_CONT_TYP_9 (C, PA)
$SC_PA_CONT_TYP[x,9] x = Number pro-
A3
tection zone
Contour type of 10th contour element
Return value
0 = G1
1 = G2
2 = G3
NC variables
204
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
MDU_PA_CONT_TYP_9 (C, PA)
$SC_PA_CONT_TYP[x,9] x = Number pro-
A3
tection zone
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDU_PA_LIM_3DIM (C, PA)
$SC_PA_LIM_3DIM[x] x = Number pro-
A3
tection zone
Limitation of protection zone applicate
Code for limitation of protection zone in the axis that is perpendicular to polygon definition (applicate)
Return value
0 = no limitation
1 = limitation in positive direction
2 = limitation in negative direction
3 = limitation in both directions
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
MDU_PA_ORI (C, PA)
$SC_PA_ORI[x] x = Number protection
A3
zone
Plane assignment of protection zone
Code for plane assignment of protection zone
Return value
0 = G17
1 = G18
2 = G19
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
205
NC variables
3.2 NC variable descriptions
MDU_PA_TW (C, PA)
$SC_PA_T_W[x] x = Number protection
A3
zone
Workpiece or tool-related protection zone
Code for workpiece or tool-oriented protection zone
Return value
0 = workpiece-related
1 = reserved
2 = reserved
3 = tool-related
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
$$numProtArea
Validity:
From NCK version 3.6
Read access
collisionAlarm (C, PA)
OD19830 $ON_COLLISION_MASK
Collision of two protection zones
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
3
Read access
acCollPos (C, PA)
Collision position in world coordinates
Contact point between two collision bodies during a collision alarm.
Corresponds with system variable $AC_COLLPOS
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
3
Read access
declarProtObject (C, PA)
Declaration of a variable protection zone
Return value
0=No object
1=WORKPIECE
2=FIXTURE
NC variables
206
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
declarProtObject (C, PA)
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
declarProtObjectString (C, PA)
String parameter(s) of a protection zone
String parameter(s) of the declaration of a variable protection zone
Units and value ranges
Physical unit:
Data type:
-
TYPE_STRING
Addressing
Line index:
Max. line index:
4
Read access
declarProtObjectReal (C, PA)
Real parameter(s) of a protection zone
Real parameters of the declaration of a variable protection zone
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
10
Read access
workpieceStatus (C, PA)
Error status after calling the procedure WORKPIECE
Error status after calling the procedure WORKPIECE
Corresponds to the system variable $P_WP_STAT
Units and value ranges
Physical unit:
Data type:
-
TYPE_WORD
Read access
fixtureStatus (C, PA)
Error status after calling the procedure FIXTURE
Error status after calling the procedure FIXTURE
Corresponds to the system variable $P_FIX_STAT
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
207
NC variables
3.2 NC variable descriptions
fixtureStatus (C, PA)
Units and value ranges
Physical unit:
Data type:
-
TYPE_WORD
Read access
3.2.3.17
RP: Arithmetic parameter
OEM-MMC: LinkItem /Channel/Parameter/...
Arithmetic parameters are special predefined variables which are addressed with the letter R followed by a number.
The contents and meaning of an arithmetic parameter are defined by the programmer of a part program. 100 R
variables are defined by default. The number of R variables can be set via machine data 28050 (MM_NUM_R_PA-
RAM).
rpa (C, RP)
$R[x] x = ParameterNo
PA
Alternative name:
R
R variables
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
MM_NUM_R_PARAM + 1
Validity:
From NCK version 3.6
Read access and write access
3.2.3.18
S: State data
OEM-MMC: LinkItem /Channel/State/...
During NC operation different internal states occur and system-specific data may change during operation. To
distinguish those from system variables, they are classified as state data.
A distinction is made between:
- NCK-specific state data
- Mode-group-specific state data
- Channel-specific state data
- Drive-specific state data (FDD)
- Drive-specific state data (MSD)
NC variables
208
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
G0Mode (C, S)
$AC_G0MODE
G00: Path axes traverse as pos. axes
G00 is active and $MC_G0_LINEAR_MODE is FALSE (Siemens mode) or $MC_EXTERN_G0_LINEAR_MODE is FALSE (ISO mode)
and therefore non-linear interpolation is active with G0, i.e. the path axes are traversed as positioning axes.
Return value
0: G00 not active
1: G00 and linear interpolation active
2: G00 and non-linear interpolation active
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
0
2
Addressing
Line index:
Max. line index:
1
Read access
aGG (C, S)
$A_GG
active G function in synchronized action
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
$$/N/YNCFL/Gruppe_NUM
Read access
aLinkTransRate (C, S)
$A_LINK_TRANS_RATE
Link transfer rate
Link transfer rate
Number of link variables that can still be transferred in the
current IPO cycle via the NCU link communication.
If this variable is read in the context of the lead, it always
outputs the maximum available bandwidth.
Units and value ranges
Physical unit:
Data type:
Minimum value:
-
TYPE_UWORD
0
Addressing
Line index:
Max. line index:
1
Read access
aMonifact (C, S)
$A_MONIFACT
Factor for tool life monitoring
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
209
NC variables
3.2 NC variable descriptions
aMonifact (C, S)
$A_MONIFACT
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DOUBLE
0
0
Addressing
Line index:
Max. line index:
1
Read access
aTcAckC (C, S)
$AC_TC_ACKC
Acknowledgment counter variable
Counter variable: aTcAckC (AcknowledgeCounter) is incremented by 1
every time the PLC acknowledges a tool management command.
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
1
Read access and write access
aTcCmdC (C, S)
$AC_TC_CMDC
Command counter variable
Counter variable: aTcCmdC (CoMmandCounter) is incremented by
1 every time the tool management outputs a command to the PLC.
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
1
Read access and write access
aTcFct (C, S)
$AC_TC_FCT
Command number
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
NC variables
210
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
aTcLfn (C, S)
$AC_TC_LFN
Source location number new tool
Source location number of new tool
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
aTcLfo (C, S)
$AC_TC_LFO
Source location number old tool
Source location number of old tool
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
aTcLmyn (C, S)
$AC_TC_LMYN
Location number of the new tool
Owner location number of the new tool
Units and value ranges
Physical unit:
Data type:
Minimum value:
Maximum value:
-
TYPE_UWORD
-1
32000
Addressing
Line index:
Max. line index:
1
Read access
aTcLtn (C, S)
$AC_TC_LTN
Target location number new tool
Target location number of new tool
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
211
NC variables
3.2 NC variable descriptions
aTcLto (C, S)
$AC_TC_LTO
Target location number old tool
Target location number of old tool
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
aTcMfn (C, S)
$AC_TC_MFN
Source magazine new tool
Source magazine of new tool
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
aTcMfo (C, S)
$AC_TC_MFO
Source magazine old tool
Source magazine number of old tool
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
aTcMmyn (C, S)
$AC_TC_MMYN
Magazine of the new tool
Owner magazine number of the new tool
Units and value ranges
Physical unit:
Data type:
Minimum value:
Maximum value:
-
TYPE_UWORD
-1
32000
Addressing
Line index:
Max. line index:
1
Read access
NC variables
212
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
aTcMtn (C, S)
$AC_TC_MTN
Target magazine new tool
Target magazine number of new tool
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
aTcMto (C, S)
$AC_TC_MTO
Target magazine old tool
Target magazine number of old tool
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
aTcStatus (C, S)
$AC_TC_STATUS
Command status
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
aTcThno (C, S)
$AC_TC_THNO
Number of toolholder
Number of toolholder for new tool
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
213
NC variables
3.2 NC variable descriptions
aTcTno (C, S)
$AC_TC_TNO
T number
T number of new tool
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
aTcToolIs (C, S)
$AC_TC_TOOLIS
Type of distance coding for the multitool
0 = Tool, 1,2,3 = Type of distance coding for the multitool
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
aTcDistance (C, S)
$AC_TC_DISTANCE
Distance of the MT place of the loaded tool
Distance of the multitool place of the loaded tool to the reference point
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
aTcMttn (C, S)
$AC_TC_MTTN
Number of the multitool of the tool
Number of the multitool of the loaded tool
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
NC variables
214
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
aTcMtptn (C, S)
$AC_TC_MTLTN
Number of the multitool place of the tool
Number of the multitool place of the loaded tool
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
aTcNumPlaces (C, S)
$AC_TC_MTNLOC
Number of defined places in the multitool
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
Addressing
Line index:
Max. line index:
1
Read access
aaAccLim (C, S)
Axial acceleration override (ACC)
Display of the axial acceleration override programmed by ACC.
Depending on $MA_DYN_LIMIT_RESET_MASK, the value can remain active after Reset.
The variable always shows the programmed acceleration override and not the currently active acceleration limit.
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
100
1
200
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access
aaAccLimA (C, S)
$AA_ACCLIMA[a]
Axial acceleration overr. main run
Axial acceleration override in main run
Return value
1-200
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
100
1
200
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
215
NC variables
3.2 NC variable descriptions
aaAccLimA (C, S)
$AA_ACCLIMA[a]
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access
aaJerkLim (C, S)
Axial jerk override (JERKLIM)
Display of the axial jerk override programmed by JERKLIM.
Depending on $MA_DYN_LIMIT_RESET_MASK, the value can remain active after Reset.
The variable always shows the programmed jerk override and not the currently active jerk limit.
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
100
1
200
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access
aaVeloLim (C, S)
Axial velocity override (VELOLIM)
Display of the axial velocity override programmed by VELOLIM.
Depending on $MA_DYN_LIMIT_RESET_MASK, the value can remain active after Reset.
The variable always shows the programmed velocity override and not the currently active velocity limit.
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
100
1
200
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access
NC variables
216
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
actCollPosMcsPacked (C, S)
Collision position in MCS
Position of a channel axis with a collision in the MCS.
The positions can be read for all configured channel axes.
Row index corresponds to
1 1st configured channel axis
2 2nd configured channel axis
20
20th configured channel axis
Units and value ranges
Physical unit:
Data type:
Initial value
mm, inch, degree, user defi-
TYPE_DOUBLE
0
ned
Addressing
Line index:
Max. line index:
MAXNUM_AXES_PER_CHAN
Read access
aaEgActive (C, S)
$AA_EG_ACTIVE[a,b]
EG link active
Electronic gear:
Link to the specified master axis is operative, i.e. activated.
Return value
0: Deactivated
1: Activated
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
0
1
Addressing
Line index:
Max. line index:
$$numMachAxes * $$numMachAxes
Read access
aaEgAx (C, S)
$AA_EG_AX[n,a]
EG axis number master axis
Electronic gear:
Axis number of nth master axis (1-n).
(Axis index = axis number - 1)
Return value
1-numMachAxes
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
1
$$numMachAxes
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
217
NC variables
3.2 NC variable descriptions
aaEgAx (C, S)
$AA_EG_AX[n,a]
Addressing
Line index:
Max. line index:
$$numMachAxes * 5
Read access
aaEgDenom (C, S)
$AA_EG_DENOM[a,b]
EG denominator link factor
Electronic gear:
Denominator of link factor for the specified master axis.
The link factor of the gear is the result of $AA_EG_NUMERA[a,b]/$AA_EG_DENOM[a,b].
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DOUBLE
1
Addressing
Line index:
Max. line index:
$$numMachAxes * $$numMachAxes
Read access
aaEgNumLa (C, S)
$AA_EG_NUM_LA[a]
EG number of master axes
Electronic gear:
Number of master axes specified with EGDEF.
If the axis has not been specified with EGDEF as slave axis,
the value is 0.
Return value
0-5
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
0
5
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access
aaEgNumera (C, S)
$AA_EG_NUMERA[a,b]
EG numerator link factor
Electronic gear:
Numerator of link factor for the specified master axis.
The link factor of the gear is the result of $AA_EG_NUMERA[a,b]/$AA_EG_DENOM[a,b].
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
NC variables
218
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
aaEgNumera (C, S)
$AA_EG_NUMERA[a,b]
$$numMachAxes * $$numMachAxes
Read access
aaEgSyn (C, S)
$AA_EG_SYN[a,b]
EG synchronous position of master axis
Electronic gear:
Synchronous position for the specified master axis.
Units and value ranges
Physical unit:
Data type:
Initial value
mm, inch, degree, user defi-
TYPE_DOUBLE
0
ned
Addressing
Line index:
Max. line index:
$$numMachAxes * $$numMachAxes
Read access
aaEgSynFa (C, S)
$AA_EG_SYNFA[a]
EG synchronous position of slave axis
Electronic gear:
Synchronous position for the slave axis.
Units and value ranges
Physical unit:
Data type:
Initial value
mm, inch, degree, user defi-
TYPE_DOUBLE
0
ned
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access
aaEgType (C, S)
$AA_EG_TYPE[a,b]
EG link type
Electronic gear:
Type of link for the specified master axis
Return value
0: Actual-value linkage
1: Setpoint linkage
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
0
1
Addressing
Line index:
Max. line index:
$$numMachAxes * $$numMachAxes
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
219
NC variables
3.2 NC variable descriptions
aaJerkLimA (C, S)
$AA_JERKLIMA[a]
Axial jerk override main run
Axial jerk override in run in
Return value
1-200
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
100
1
200
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access
aaMeasP1Valid (C, S)
$AA_MEAS_P1_VALID
Save axial measuring point 1
Save axial measuring point P1 for workpiece and
tool measurement
Return value
0: Clear axial measuring point
1: Write actual axial values to axial measuring point
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_DWORD
0
0
1
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access and write access
aaMeasP2Valid (C, S)
$AA_MEAS_P2_VALID
Save axial measuring point 2
Save axial measuring point P2 for workpiece and
tool measurement
Return value
0: Clear axial measuring point
1: Write actual axial values to axial measuring point
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_DWORD
0
0
1
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access and write access
NC variables
220
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
aaMeasP3Valid (C, S)
$AA_MEAS_P3_VALID
Save axial measuring point 3
Save axial measuring point P3 for workpiece and
tool measurement
Return value
0: Clear axial measuring point
1: Write actual axial values to axial measuring point
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_DWORD
0
0
1
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access and write access
aaMeasP4Valid (C, S)
$AA_MEAS_P4_VALID
Save axial measuring point 4
Save axial measuring point P4 for workpiece and
tool measurement
Return value
0: Clear axial measuring point
1: Write actual axial values to axial measuring point
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_DWORD
0
0
1
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access and write access
aaMeasPoint1 (C, S)
$AA_MEAS_POINT1
1st measuring point
1st measuring point for workpiece and tool measurement
Units and value ranges
Physical unit:
Data type:
Initial value
mm, inch, user defined
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access and write access
aaMeasPoint2 (C, S)
$AA_MEAS_POINT2
2nd measuring point
2nd measuring point for workpiece and tool measurement
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
221
NC variables
3.2 NC variable descriptions
aaMeasPoint2 (C, S)
$AA_MEAS_POINT2
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access and write access
aaMeasPoint3 (C, S)
$AA_MEAS_POINT3
3rd measuring point
3rd measuring point for workpiece and tool measurement
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access and write access
aaMeasPoint4 (C, S)
$AA_MEAS_POINT4
4th measuring point
4th measuring point for workpiece and tool measurement
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access and write access
aaMeasSetangle (C, S)
$AA_MEAS_SETANGLE
Measurement setpoint angle
Setpoint angle of an axis
Units and value ranges
Physical unit:
Data type:
Degree, user defined
TYPE_DOUBLE
Read access and write access
aaMeasSetpoint (C, S)
$AA_MEAS_SETPOINT
Measurement setpoint position
Setpoint position of edge, corner or hole
Units and value ranges
Physical unit:
Data type:
NC variables
222
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
aaMeasSetpoint (C, S)
$AA_MEAS_SETPOINT
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access and write access
aaMeasSpValid (C, S)
$AA_MEAS_SP_VALID
Save axial setpoint
Save axial setpoint for workpiece and
tool measurement
Return value
0: Clear axial setpoint
1: Validate axial setpoint
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_DWORD
0
0
1
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access and write access
aaVeloLimA (C, S)
$AA_VELOLIMA[a]
Axial velocity overr. main run
Axial velocity override in main run
Return value
1-200
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
100
1
200
Addressing
Line index:
Max. line index:
$$numMachAxes
Read access
acAlarmStat (C, S)
$AC_ALARM_STAT
ESR alarm status
!=0: Alarms are pending, the appropriate coded alarm reactions can be used as source for
"Extended stop and retract".
Return value
The data is bit-coded. Individual states can therefore be masked or
evaluated separately if necessary (bits excluded below produce a value of 0)
Bit2 = 1: NOREADY (active rapid deceleration + cancellation of servo enable)
Bit6 = 1: STOPBYALARM (ramp stop of all channel axes)
Bit9 = 1: SETVDI (VDI interface signal alarm setting)
Bit13 = 1: FOLLOWUPBYALARM (follow-up)
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
223
NC variables
3.2 NC variable descriptions
acAlarmStat (C, S)
$AC_ALARM_STAT
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_UWORD
0
Addressing
Line index:
Max. line index:
1
Read access
acAsup (C, S)
$AC_ASUP
Reason for the activation of an ASUB
Code number for the cause of activation of an ASUB
Return value
The reasons are bit-coded.
BIT0: Activation because of: User interrupt "ASUB with Blsync".
BIT1: Activation because of: User interrupt "ASUB".
BIT2: Activation because of: User interrupt "ASUB from channel state Ready".
BIT3: Activation because of: User interrupt "ASUB in manual mode".
BIT4: Activation because of: Activation because of: User interrupt "ASUB".
BIT5: Activation because of: Abort of the subroutine repetition.
BIT6: Activation because of: Activation of decoding single block.
BIT7: Activation because of: Activation of DDTG.
BIT8: Activation because of: Activation of axis synchronization.
BIT9: Activation because of: Change of operating mode.
BIT10: Activation because of: Program continuation under TeachIn or after TeachIn deactivation.
BIT11: Activation because of: Selection overstore.
BIT12: Activation because of: Alarm with reaction compensation block with REPOS ( COMPB-
LOCKWITHREORG).
BIT13: Activation because of: Retraction motion with G33 and Stop.
BIT14: Activation because of: Activation of dry run feed.
BIT15: Activation because of: Deactivation of dry run feed.
BIT16: Activation because of: Activation of skip block.
BIT17: Activation because of: Deactivation of skip block.
BIT18: Activation because of: Activate machine data.
BIT19: Activation because of: Activate tool offset.
BIT20: Activation because of: System ASUB after search type SERUPRO has reached the search
target.
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DWORD
0
0
Addressing
Line index:
Max. line index:
1
Read access
NC variables
224
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
acAxCtSwA (C, S)
$AC_AXCTSWA[CTn]
Status of axis container
Channel status of axis container rotation
Return value
TRUE: The channel has enabled rotation for the axis container
and rotation is still in progress.
FALSE: Axis container rotation is already finished
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
0
1
Addressing
Line index:
Max. line index:
$$numContainer
Read access
acConeAngle (C, S)
$AC_CONE_ANGLE
Taper angle
Currently effective taper angle for taper turning.
The taper angle is specified by the setting data $SC_CONE_ANGLE and is
effective in the operating mode JOG only.
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
Degree
TYPE_DOUBLE
0
-90
90
Addressing
Line index:
Max. line index:
1
Read access
acDelt (C, S)
$AC_DELT
Stored distance-to-go of the path in the WCS
Stored distance-to-go of the path in the WCS after delete-distance-to-go of the path DELDTG for synchronous action (Note: for
SYNACT only)
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
acDtbb (C, S)
$AC_DTBB
Distance from beginning of the block in the BCS
Distance from the beginning of the block in the BCS (Note: SYNACT only)
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
225
NC variables
3.2 NC variable descriptions
acDtbb (C, S)
$AC_DTBB
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
acDtbw (C, S)
$AC_DTBW
Distance from the beginning of block in the WCS
Distance from the beginning of the block in the WCS
(Note: for SYNACT only)
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
acDteb (C, S)
$AC_DTEB
Distance to the end of the block in the BCS
Distance to the end of the block in the BCS (Note: for SYNACT only)
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
acLookahTest (C, S)
$AC_LOOKAH_TEST[n]
Test variable for LookAhead
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Read access and write access
acSimMode (C, S)
Simulation mode
Variable $AC_SIM_MODE determines the simulation mode. The following values are possible:
0: Simulation not active.
1: Simulation mode active.
NC variables
226
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
acSimMode (C, S)
Units and value ranges
Physical unit:
Data type:
Minimum value:
Maximum value:
-
TYPE_DWORD
0
1
Addressing
Line index:
Max. line index:
1
Read access
acSimTimeBlock (C, S)
Block processing time in the simulation
For the simulation: block processing time in seconds
Units and value ranges
Physical unit:
Data type:
s, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
acSimTimeStep (C, S)
Time step in the simulation
For the simulation: time step in seconds
Units and value ranges
Physical unit:
Data type:
s, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
acTrafoPar (C, S)
$AC_TRAFO_PAR[n]
Parameter(s) of the current transformation
Supplies the value of parameter 'n' of the current transformation, e.g. the cylinder diameter in the case of TRACYL
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
8
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
227
NC variables
3.2 NC variable descriptions
actToolDataBeforeSearch (C, S)
$P_
_BEFORE_SEARCH_RUN
Active tool offset data before the search
Data for determining the active tool offset before the search, that is in reset status before the start of the search.
After reaching the search target, the value is set to the current value for each programming of master tool holder, spindle, D
no or DL no.
-P1: Master tool holder or spindle before the search ($AC_MTHNUM_BEFORE_SEARCH)
Programming "MTH(no)" or "MS(no)" after reaching the search target, this variable then returns the same value as
acMthNum.
-P2: Active D no. before the search (see $P_D_BEFORE_SEARCH)
Programming "D" after reaching the search target, this variable then returns the same value as actDNumber.
-P3: Active DL no. before the search (see $P_DL_BEFORE_SEARCH)
Programming "DL" after reaching the search target, this variable then returns the same value as actDLNumber.
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
$$numSearchRunToolParams
Read access
NC variables
228
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
acsAxFrame (C, S)
Current axial ACS frame
The variable acsAxFrame returns the axial frames of the active ACS (SZS) frames.
The variable has the following structure:
Row index Description
1 - 2
Frame for the 1st channel axis
3 - 4
Frame for the 2nd channel axis
5 - 6
Frame for the 3rd channel axis
7 - 8
Frame for the 4th channel axis
9 - 10
Frame for the 5th channel axis
39 - 40
Frame for the 20th channel axis
The axial frame consists of two values:
Double axSumTrans
Double axScale
For example, to read the first five channel axes, the row index must be entered as = 1 and the maximum row index as 10 ( 5 *
2 ).
The axial frames are returned for all configured channel axes without any axis gaps.
Note:
axSumTrans: Total translation
axScale: Scaling. In the event of a negative value, the axis is mirrored.
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
40
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
229
NC variables
3.2 NC variable descriptions
acsGeoFrame (C, S)
Current ACS contour frame
The variable acsGeoFrame returns the current ACS contour frame.
The variable has the following structure:
Row index Description
1 - 3
Double geoSumTrans[GEODIM]
4 - 6
Double geoScale[GEODIM]
7 - 9
Double geoRot[GEODIM]
10 - 12
Double geoShear[GEODIM]
The maximum row index entered specifies how many values are to be read at any one time.
Example: Row index = 1 and the maximum index = 12: This enables the complete contour frame to be read (12 values).
Note:
GEODIM:
3 (number of geometry axes)
geoSumTrans: Total translation of the 1st to the 3rd geometry axis
geoScale: Scaling of the 1st to the 3rd geometry axis. In the event of a negative value, the axis is mirrored.
geoRot:
Rotation around the 1st to the 3rd geometry axis. The MD has to determine whether the notation is RPY or Euler.
geoShear: Shear angle of the 1st to the 3rd geometry axis (the shear angle is 90 degrees in orthonormal coordinate systems)
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
12
Read access
actOriToolLengthENS (C, S)
X, Y, Z tool components in the SZS
X, Y, Z components in the SZS of the active tool length, taking into account the tool orientation, including adapter data,
mirrorings and TCARR
(orientable tool carrier).
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
3
Read access
NC variables
230
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
actToolBasePosMcsPacked (C, S)
Position of the tool holder in the MCS
Position of a channel axis in the MCS with reference to the tool holder.
The positions can be read for all configured channel axes without any axis gaps.
Row index Corresponds to
1
1st configured channel axis
2
2nd configured channel axis
20
20th configured channel axis
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
MAXNUM_AXES_PER_CHAN
Read access
actToolEdgeCenterPosBcsPacked (C, S)
Position of the edge center in the BCS
Position of a channel axis in the BCS with reference to the edge center.
The positions can be read for all configured channel axes without any axis gaps.
Row index Corresponds to
1
1st configured channel axis
2
2nd configured channel axis
20
20th configured channel axis
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
MAXNUM_AXES_PER_CHAN
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
231
NC variables
3.2 NC variable descriptions
actToolEdgeCenterPosEnsPacked (C, S)
Position of the edge center in the SZS
Position of a channel axis in the SZS coordinate system with reference to the edge center.
The positions can be read for all configured channel axes without any axis gaps.
Row index Corresponds to
1
1st configured channel axis
2
2nd configured channel axis
20
20th configured channel axis
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
MAXNUM_AXES_PER_CHAN
Read access
actToolEdgeCenterPosEnsPathn1 (C, S)
Position of the TCP in the SZS
TCP SZS positions of the path axes with path parameter = 1. Packed for all configured channel axes (without gaps).
The positions do not have to correspond to the programmed positions (TRC, WAB, etc.)
The positions can be read for all configured channel axes without any axis gaps.
Row index Corresponds to
1
1st configured channel axis
2
2nd configured channel axis
20
20th configured channel axis
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
MAXNUM_AXES_PER_CHAN
Read access
NC variables
232
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
cmdToolEdgeCenterPosBcsPathn1 (C, S)
End position of the TCP in the BCS
TCP BCS positions of the path axes with path parameter = 1. Packed for all configured channel axes (without gaps).
The positions do not have to correspond to the programmed positions (TRC, WAB, etc.)
The positions can be read for all configured channel axes without any axis gaps.
Row index Corresponds to
1
1st configured channel axis
2
2nd configured channel axis
20
20th configured channel axis
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
MAXNUM_AXES_PER_CHAN
Read access
cmdToolEdgeCenterPosMcsPathn1 (C, S)
Position of the TCP in the MCS
TCP MCS positions of the path axes with path parameter = 1. Packed for all configured channel axes (without gaps).
The positions do not have to correspond to the programmed positions (TRC, WAB, etc.)
The positions can be read for all configured channel axes without any axis gaps.
Row index Corresponds to
1
1st configured channel axis
2
2nd configured channel axis
20
20th configured channel axis
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
MAXNUM_AXES_PER_CHAN
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
233
NC variables
3.2 NC variable descriptions
auxfu (C, S)
Current auxiliary function
The variable is only used to read the auxiliary function during the output to the PLC.
This variable may only be used with the event AUXFU.
The variable has the following structure:
Double auxFuType;
Double extension;
Double value;
auxFuType is an integer value and can return the following values:
0: GARBAGE
1: M
2: M (generated by system)
3: H
4: S
5: S (generated by system)
6: T
7: D
8: DL
9: F
Value : floating point with S / F / H ($MC_AUXFU_H_TYPE_INT = 0)
Integer value with M / T / D / DL / H ($MC_AUXFU_H_TYPE_INT = 1)
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
3
Read access
NC variables
234
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
axesActiveInChan (C, S)
Bit mask of all active axes in the channel
Bit mask of all active axes in the channel.
There are many types of axes, e.g. geometry axis, positioning axis, command axis, PLC axis etc. In this mask, only those axes
are marked which, in principle, can be interpolated by an interpolator in this channel.
Bit Description
0
1. Channel axis
1
2. Channel axis
20
20. Channel axis
Units and value ranges
Physical unit:
Data type:
-
TYPE_UDWORD
Addressing
Line index:
Max. line index:
1
Read access
blockProgInfo (C, S)
$AC_BLOCK_PROGSTATE
Information of active block in the interpolator
Returns the information of a main run block.
Return value
Bit-coded:
Bit 0: Block is end of main program ( M02, M17, M30 or RET(ASUB) )
Bit 1: Block is end of subprogram
Bit 2: Block is last initializing block
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DWORD
0
0
Addressing
Line index:
Max. line index:
1
Read access
chanAxesIpoAtEnd (C, S)
Channel axis has reached the end of its movement
Bit field of channel axes have reached their end of movement.
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_UDWORD
0
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
235
NC variables
3.2 NC variable descriptions
chanAxesIpoAtEnd (C, S)
Addressing
Line index:
Max. line index:
1
Read access
speedCtrlSpindlesMask (C, S)
Speed-controlled spindles in the channel
Bit array of the speed-controlled spindles of a channel.
If axes in the channel are defined with N20070 $MC_AXCONF_MACHAX_USED[n], speedCtrlSpindlesMask indicates all the
speed-controlled spindles.
For example, if 6 axes are defined in the channel, and axes 4 and 5 are spindles, speedCtrlSpindlesMask returns the 0x18.
Any gaps in the bit array, e.g. if axis 3 is not defined, are closed in the mask.
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_UDWORD
0
Addressing
Line index:
Max. line index:
1
Read access
cmdTrafoParS (C, S)
$P_TRAFO_PAR[n]
Parameter(s) of the programmed transformation
Supplies the value of parameter 'n' of the programmed transformation, e.g. the cylinder diameter in the case of TRACYL
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
8
Read access
acDtew (C, S)
$AC_DTEW
Distance to the end of the block in the WCS
Distance to the end of the block in the WCS
(Note: for SYNACT only)
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
NC variables
236
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
acEsrTrigger (C, S)
$AC_ESR_TRIGGER
Activation of ESR
Activation of "NC-controlled ESR"
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
0
1
Addressing
Line index:
Max. line index:
1
Read access
acFGo (C, S)
$AC_F_G0
Max. rapid traverse rate in the block
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
mm/min, inch/min, user de-
TYPE_DOUBLE
0
0
fined
Addressing
Line index:
Max. line index:
1
Read access
acFct0 (C, S)
$AC_FCT0[x] x = PolynomNo
a0-coeff. nth polynominal for synchonous action
a0-coefficient of the nth polynominal for the synchronous action SYNFCT / function FCTDEF n
(Note: for SYNACT only)
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_FCTDEF_ELEMENTS
Read access
acFct1 (C, S)
$AC_FCT1[x] x = PolynomNo
a1-coeff. nth polynominal for synchonous action
a1-coefficient of the nth polynominal for the synchronous action SYNFCT / function FCTDEF n
(Note: for SYNACT only)
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
237
NC variables
3.2 NC variable descriptions
acFct1 (C, S)
$AC_FCT1[x] x = PolynomNo
$MC_MM_NUM_FCTDEF_ELEMENTS
Read access
acFct2 (C, S)
$AC_FCT2[x] x = PolynomNo
a2-coeff. nth polynominal for synchonous action
a2-coefficient of the nth polynominal for the synchronous action
SYNFCT / function FCTDEF n
(Note: for SYNACT only)
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_FCTDEF_ELEMENTS
Read access
acFct3 (C, S)
$AC_FCT3[x] x = PolynomNo
a3-coeff. nth polynominal for synchonous action
a3-coefficient of the nth polynominal for the synchronous action
SYNFCT / function FCTDEF n
(Note: for SYNACT only)
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_FCTDEF_ELEMENTS
Read access
acFctll (C, S)
$AC_FCTLL[x] x = PolynomNo
Lower limit nth polynominal for synchronous action
Lower limit of the nth polynominal for the synchronous action SYNFCT / function FCTDEF n
(Note: for SYNACT only)
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_FCTDEF_ELEMENTS
Read access
NC variables
238
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
acFctul (C, S)
$AC_FCTUL[x] x = PolynomNo
Upper limit nth polynominal for synchronous action
Upper limit of the nth polynominal for the synchronous action SYNFCT / function FCTDEF n
(Note: for SYNACT only)
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
$MC_MM_NUM_FCTDEF_ELEMENTS
Read access
acIwStat (C, S)
$AC_IW_STAT
Current position of machine
Return value
Bit-coded:
Bit 0: Tool inv. position
Bit 1: Axis 2/3 position
Bit 2: Axis 5 position
Bit 3-31: Not yet assigned
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DWORD
0
Addressing
Line index:
Max. line index:
1
Read access
acIwTu (C, S)
$AC_IW_TU
Current position of channel axes
Return value
Bit-coded:
Bit 0: Channel axis 1 position
Bit 1: Channel axis 2 position
Bit 2: Channel axis 3 position
Bit 3: Channel axis 4 position
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DWORD
0
Addressing
Line index:
Max. line index:
1
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
239
NC variables
3.2 NC variable descriptions
acJogCoord (C, S)
$AC_JOG_COORD
Coordinate system manual travel
Setting the coordinate system for the manual travel
Return value
0: Work
1: SZS
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_DWORD
0
0
1
Read access and write access
acLiftFast (C, S)
$AC_LIFTFAST
Information about LIFTFAST
Information about the execution of LIFTFAST.
At the start of the LIFTFAST operation, the variable
is set internally by the NC to the value "1".
The variable must be reset to the initial state ($AC_LIFTFAST=0)
by the evaluating program (if available), in order to be able to
detect a subsequent LIFTFAST.
Return value
0: Initial state
1: LIFTFAST has been executed
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
0
1
Addressing
Line index:
Max. line index:
1
Read access
acMea (C, S)
$AC_MEA
Touch probe has switched
Return value
No. of touch probe
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
0
1
Addressing
Line index:
Max. line index:
2
Read access
acMeasActPlane (C, S)
$AC_MEAS_ACT_PLANE
Plane setting
Plane setting for measurement calculation
Return value
0: G17, 1: G18, 2: G19
NC variables
240
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
acMeasActPlane (C, S)
$AC_MEAS_ACT_PLANE
Units and value ranges
Physical unit:
Data type:
Minimum value:
Maximum value:
-
TYPE_DWORD
0
2
Addressing
Line index:
Max. line index:
1
Read access and write access
acMeasChbfr (C, S)
$AC_MEAS_CHBFR
Channel basic frame screen form
Channel basic frame screen form for setting up the new frame
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DWORD
0
0
Read access and write access
acMeasChsfr (C, S)
$AC_MEAS_CHSFR
System frame bit screen form
System frame bit screen form for setting up the new frame
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DWORD
0
0
Read access and write access
acMeasCornerAngle (C, S)
$AC_MEAS_CORNER_ANGLE
Corner cutting angle
Calculated cutting angle of corner
Units and value ranges
Physical unit:
Data type:
Degree, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
acMeasCornerSetangle (C, S)
$AC_MEAS_CORNER_SETANGLE
Setpoint cutting angle
User-selectable setpoint cutting angle of corner
Return value
Permissible input range between 0 and 180 degrees
Units and value ranges
Physical unit:
Data type:
Minimum value:
Maximum value:
Degree, user defined
TYPE_DOUBLE
0
180.0
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
241
NC variables
3.2 NC variable descriptions
acMeasCornerSetangle (C, S)
$AC_MEAS_CORNER_SETANGLE
Addressing
Line index:
Max. line index:
1
Read access and write access
acMeasDNumber (C, S)
$AC_MEAS_D_NUMBER
Tool edge number
Selected tool edge number
Units and value ranges
Physical unit:
Data type:
Minimum value:
-
TYPE_DWORD
0
Addressing
Line index:
Max. line index:
1
Read access and write access
acMeasDiameter (C, S)
$AC_MEAS_DIAMETER
Diameter
Calculated diameter
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
acMeasDirApproach (C, S)
$AC_MEAS_DIR_APPROACH
Approach direction
Approach direction towards workpiece
Return value
0: +x 1: -x 2: +y 3: -y 4: +z 5: -z
Units and value ranges
Physical unit:
Data type:
Minimum value:
Maximum value:
-
TYPE_DWORD
0
5
Addressing
Line index:
Max. line index:
1
Read access and write access
NC variables
242
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
acMeasFineTrans (C, S)
$AC_MEAS_FINE_TRANS
Fine offset
Correction in fine offset
Return value
0: Correction in coarse translation
1: Correction in fine translation
Units and value ranges
Physical unit:
Data type:
Minimum value:
Maximum value:
-
TYPE_DWORD
0
1
Addressing
Line index:
Max. line index:
1
Read access and write access
acMeasFrameSelect (C, S)
$AC_MEAS_FRAME_SELECT
Frame selection
The frame calculated during workpiece measurement is
entered in the selected frame.
Return value
0:
$P_SETFR
10.. 25: $P_CHBFR[0..15]
50.. 65: $P_NCBFR[0..15]
100.. 199: $P_UIFR[0..99]
1010..1025: $P_CHBFR[0..15]
1050..1065: $P_NCBFR[0..15]
Units and value ranges
Physical unit:
Data type:
Minimum value:
Maximum value:
-
TYPE_DWORD
0
1065
Addressing
Line index:
Max. line index:
1
Read access and write access
acMeasInput (C, S)
$AC_MEAS_INPUT[n]
Data for measurement
Data for the workpiece and tool measurement
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DOUBLE
0
Addressing
Line index:
Max. line index:
10
Read access and write access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
243
NC variables
3.2 NC variable descriptions
acMeasLatch (C, S)
$AC_MEAS_LATCH
Save measuring point
Save measuring points for workpiece and tool measurement
Return value
0: Clear measuring point
1: Write current axial values to measuring point
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_DWORD
0
0
1
Addressing
Line index:
Max. line index:
4
Read access and write access
acMeasNcbfr (C, S)
$AC_MEAS_NCBFR
Global basic frame screen form
Global basic frame screen form for setting up the new frame
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DWORD
0
0
Read access and write access
acMeasP1Coord (C, S)
$AC_MEAS_P1_COORD
Coordinate system of the 1st measuring point
Return value
0: Work 1: BCS 2: MCS
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DWORD
0
0
Read access and write access
acMeasP2Coord (C, S)
$AC_MEAS_P2_COORD
Coordinate system of the 2nd measuring point
Return value
0: Work 1: BCS 2: MCS
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DWORD
0
0
Read access and write access
acMeasP3Coord (C, S)
$AC_MEAS_P3_COORD
Coordinate system of the 3rd measuring point
Return value
0: Work 1: BCS 2: MCS
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
NC variables
244
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
acMeasP3Coord (C, S)
$AC_MEAS_P3_COORD
-
TYPE_DWORD
0
0
Read access and write access
acMeasP4Coord (C, S)
$AC_MEAS_P4_COORD
Coordinate system of the 4th measuring point
Return value
0: Work 1: BCS 2: MCS
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DWORD
0
0
Read access and write access
acMeasPframe (C, S)
$AC_MEAS_PFRAME
Programmable frame
Programmable frame is not included
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_DWORD
0
0
1
Read access and write access
acMeasResults (C, S)
$AC_MEAS_RESULTS[n]
Measurement results
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
10
Read access
acMeasScaleunit (C, S)
$AC_MEAS_SCALEUNIT
Unit of measurement
Unit of measurement for input and output values
Return value
0: Unit of measurement as configured
1: Unit of measurement in relation to active G code G70/G700/G71/G710
Units and value ranges
Physical unit:
Data type:
Minimum value:
-
TYPE_DWORD
0
Addressing
Line index:
Max. line index:
1
Read access and write access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
245
NC variables
3.2 NC variable descriptions
acMeasSema (C, S)
$AC_MEAS_SEMA
Workpiece measurement semaphore
Variable for disabling and enabling the measurement interface
Return value
0: Not assigned
1: Assigned
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_DWORD
0
0
1
Addressing
Line index:
Max. line index:
1
Read access and write access
acMeasSetCoord (C, S)
$AC_MEAS_SET_COORD
Coordinate system of the set point
Return value
0: Work 1: BCS 2: MCS
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DWORD
0
0
Read access and write access
acMeasTNumber (C, S)
$AC_MEAS_T_NUMBER
Tool number
Selected tool number
Units and value ranges
Physical unit:
Data type:
Minimum value:
-
TYPE_DWORD
0
Addressing
Line index:
Max. line index:
1
Read access and write access
acMeasToolLength (C, S)
$AC_MEAS_TOOL_LENGTH
Tool length
Calculated tool length
Units and value ranges
Physical unit:
Data type:
mm, inch, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
NC variables
246
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
acMeasToolMask (C, S)
$AC_MEAS_TOOL_MASK
Tool setting
Tool setting for the measurement calculation
Return value
Bit 0: Tool radius is not included in the calculation
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DWORD
0
0
Read access and write access
acMeasType (C, S)
$AC_MEAS_TYPE
Measurement type
Measurement type specification
Return value
0: Default
1: x edge
2: y edge
3: z edge
4: Corner 1
5: Corner 2,
6: Corner 3
7: Corner 4
8: Hole
9: Shaft
10: Tool length
11: Tool diameter
12: Groove
13: Web
14: Actual value setting for geo and special axes
15: Actual value setting for special axes only
16: Edge_2P
17: Plane_Angles
18: Plane_Normal
19: Dimension_1
20: Dimension_2
21: Dimension_3
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_DWORD
0
0
21
Addressing
Line index:
Max. line index:
1
Read access and write access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
247
NC variables
3.2 NC variable descriptions
acMeasUifr (C, S)
$AC_MEAS_UIFR
Settable data management frame
Settable data management frame for setting up the new frame
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_DWORD
0
0
99
Read access and write access
acMeasValid (C, S)
$AC_MEAS_VALID
Validity bits
Validity bits for measurement input values
Return value
Bit 0: $AA_MEAS_POINT1[axis]
Bit 1: $AA_MEAS_POINT2[axis]
Bit 2: $AA_MEAS_POINT3[axis]
Bit 3: $AA_MEAS_POINT4[axis]
Bit 4: $AA_MEAS_SETPOINT[axis]
Bit 5: $AC_MEAS_WP_SETANGLE
Bit 6: $AC_MEAS_CORNER_SETANGLE
Bit 7: $AC_MEAS_T_NUMBER
Bit 8: $AC_MEAS_D_NUMBER
Bit 9: $AC_MEAS_DIR_APPROACH
Bit 10: $AC_MEAS_ACT_PLANE
Bit 11: $AC_MEAS_FRAME_SELECT
Bit 12: $AC_MEAS_TYPE
Bit 13: $AC_MEAS_FINE_TRANS
Units and value ranges
Physical unit:
Data type:
Minimum value:
-
TYPE_DWORD
0
Addressing
Line index:
Max. line index:
1
Read access and write access
acMeasWpAngle (C, S)
$AC_MEAS_WP_ANGLE
Workpiece position angle
Calculated workpiece position angle
Units and value ranges
Physical unit:
Data type:
Degree, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
NC variables
248
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
acMeasWpSetangle (C, S)
$AC_MEAS_WP_SETANGLE
Setpoint workpiece position angle
User-selectable setpoint workpiece position angle
Return value
Permissible input range less than +/- 90 degrees
Units and value ranges
Physical unit:
Data type:
Minimum value:
Maximum value:
Degree, user defined
TYPE_DOUBLE
-90.0
90.0
Addressing
Line index:
Max. line index:
1
Read access and write access
acMonMin (C, S)
$AC_MONMIN
Actual tool monitoring value to the setpoint
Ratio of the actual tool monitoring value to the setpoint
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DOUBLE
0
0
Addressing
Line index:
Max. line index:
1
Read access
acMsNum (C, S)
$AC_MSNUM
Number of the master spindle
Returns the number of the current master spindle.
Return value
o = no spindle available
o = 1 ... n = number of the master spindle
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
1
Read access
acMthNum (C, S)
$AC_MTHNUM
Number of the current master tool holder
Number of the current master tool holder.
Is only meaningful with active magazine management.
Return value
0: No master tool holder available
1..n: Number of the master tool holder
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
249
NC variables
3.2 NC variable descriptions
acMthNum (C, S)
$AC_MTHNUM
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_UWORD
0
0
Addressing
Line index:
Max. line index:
1
Read access
acOvr (C, S)
$AC_OVR
Path override for synchronous actions
Path override for synchronous actions (Note: for SYNACT only)
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
acPRTimeA (C, S)
Program runtime - downtime
In automatic mode: Exact recording of downtime. For simulation: Estimation of downtime in seconds.
Units and value ranges
Physical unit:
Data type:
s, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access and write access
acPRTimeM (C, S)
Program runtime - machining time
In automatic mode: Exact recording of machining time. For simulation: Estimation of machining time in seconds.
Units and value ranges
Physical unit:
Data type:
s, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access and write access
NC variables
250
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
acPRTimeB (C, S)
Machining time of the block
In automatic mode: Exact recording of machining time of the block. For simulation: Estimation of machining time of the block
in seconds.
Units and value ranges
Physical unit:
Data type:
s, user defined
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
acPathAcc (C, S)
$AC_PATHACC
Path acceleration for real-time events
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
m/s2, 1000 inch/ s2, user de-
TYPE_DOUBLE
0
0
fined
Addressing
Line index:
Max. line index:
1
Read access
acPathJerk (C, S)
$AC_PATHJERK
Path jerk for real-time events
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
mm/s3, 1000 inch / s3, user
TYPE_DOUBLE
0
0
defined
Addressing
Line index:
Max. line index:
1
Read access
acPathn (C, S)
$AC_PATHN
Normalized path parameter
Normalized path parameter (Note: for SYNACT only)
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
251
NC variables
3.2 NC variable descriptions
acPlcOvr (C, S)
$AC_PLC_OVR
PLC override for synchronized actions
Path override for synchronized actions specified by the PLC
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DOUBLE
100
0
Addressing
Line index:
Max. line index:
1
Read access
acPltbb (C, S)
$AC_PLTBB
Path from beginning of the block in the BCS
Path length from the beginning of the block in the BCS (Note: for SYNACT only)
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
acPlteb (C, S)
$AC_PLTEB
Path to the end of the block in the BCS
Path length to the end of the block in the BCS (Note: for SYNACT only)
Units and value ranges
Physical unit:
Data type:
-
TYPE_DOUBLE
Addressing
Line index:
Max. line index:
1
Read access
acProg (C, S)
$AC_PROG
Program status according to $AC_PROG
Program status
(identical to progStatus but with coding that corresponds to $AC_PROG)
Return value
0: aborted (reset)
1: halted (stop)
2: running (active)
3: waiting
4: interrupted
NC variables
252
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
acProg (C, S)
$AC_PROG
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_UWORD
0
Addressing
Line index:
Max. line index:
1
Read access
acPtpSup (C, S)
Cart. PTP travel is supported
Cartesian point-to-point travel (PTP) is supported by transformation
Return value
0: Cart. PTP travel is not supported
1: Cart. PTP travel is supported
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
Maximum value:
-
TYPE_UWORD
0
0
1
Addressing
Line index:
Max. line index:
1
Read access
acStat (C, S)
$AC_STAT
Channel status according to $AC_STAT
Channel status
(identical to chanStatus but with coding that corresponds to $AC_STAT)
Return value
0: reset
1: interrupted
2: active
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_UWORD
0
Addressing
Line index:
Max. line index:
1
Read access
acSynaMem (C, S)
$AC_SYNA_MEM
Free memory for synchronous actions
Free memory for synchronous actions: Shows how many elements of the memory set with $MC_MM_NUM_SYNC_ELEMENTS
are still free.
Units and value ranges
Physical unit:
Data type:
-
TYPE_UWORD
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4
253
NC variables
3.2 NC variable descriptions
acSynaMem (C, S)
$AC_SYNA_MEM
Addressing
Line index:
Max. line index:
1
Read access
acSyncActLoad (C, S)
$AC_SYNC_ACT_LOAD
Current runtime for synchronized actions
Current runtime for synchronized actions of the last IPO cycle in the channel
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DOUBLE
0
0
Addressing
Line index:
Max. line index:
1
Read access
acSyncAverageLoad (C, S)
$AC_SYNC_AVERAGE_LOAD
Average runtime for synchronized actions
Average runtime for synchronized actions of an IPO cycle in the channel
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DOUBLE
0
0
Addressing
Line index:
Max. line index:
1
Read access
acSyncMaxLoad (C, S)
$AC_SYNC_MAX_LOAD
Longest runtime for synchronized actions
Longest runtime for synchronized actions of an IPO cycle in the channel
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DOUBLE
0
0
Addressing
Line index:
Max. line index:
1
Read access
acTaneb (C, S)
$AC_TANEB
Tangent angle at the block end point
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DOUBLE
0
0
NC variables
254
List Manual, 10/2020, 6FC5397-3CP40-6BA4
NC variables
3.2 NC variable descriptions
acTaneb (C, S)
$AC_TANEB
Addressing
Line index:
Max. line index:
1
Read access
acTc (C, S)
$AC_TC
Active tool carrier
Units and value ranges
Physical unit:
Data type:
Initial value
Minimum value:
-
TYPE_DWORD
0
0
Addressing
Line index:
Max. line index:
1
Read access
acTcAckt (C, S)
$AC_TC_ACKT
Trigger variable ACKnowledgeTrigger
Trigger variable ACKnowledgeTrigger always assumes a value of 1
for an IPO cycle when the PLC acknowledges a command of the tool management.
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DWORD
0
Addressing
Line index:
Max. line index:
1
Read access
acTcCmdt (C, S)
$AC_TC_CMDT
Trigger variable: CoMmadTrigger
Trigger variable: CoMmadTrigger always assumes a value of 1 for an
IPO cycle when a new command of the magazine management is output to the PLC.
Units and value ranges
Physical unit:
Data type:
Initial value
-
TYPE_DWORD
0
Addressing
Line index:
Max. line index:
1
Read access
acThreadPitch (C, S)
$AC_THREAD_PITCH
Programmed lead
Units and value ranges
Physical unit:
Data type:
Initial value
NC variables
List Manual, 10/2020, 6FC5397-3CP40-6BA4