DAF 95XF. Manual - part 568

 

  Index      DAF     DAF 95XF Series - service repair manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  566  567  568  569   ..

 

 

DAF 95XF. Manual - part 568

 

 

8

DIAGNOSIS

Contents

2

1

ǹ 0001

8

Single rear axle 1347

DIAGNOSIS

1-1

1. SINGLE REAR AXLE 1347

1.1 FAULT-FINDING TABLE

FAULT: NOISES IN REAR AXLE AND DRIVE ASSEMBLY

Possible cause

Remedy

Oil level too low

Top up oil

Oil with incorrect viscosity

Drain oil and top up

Loosened attachment bolts or broken
differential-lock parts

Drain oil and check drained oil for presence of
pieces of metal

Pinion-bearing play

Adjust and/or replace

FAULT: OIL LEAKAGE

Possible cause

Remedy

Oil level too high

Drain oil

Oil with incorrect viscosity

Drain oil and top up

Leaking oil sealing ring

Replace oil sealing ring

Bleeding system blocked

Clean or replace the bleeding system

Oil leakage between the differential housing
mating surfaces

Clean mating surfaces and apply new sealing
compound

FAULT: DIFFERENTIAL LOCK IS NOT FUNCTIONING

Possible cause

Remedy

No air pressure at engaging cylinder

Check compressed-air system

Defective pneumatic control

Check or replace pneumatic switch

Defective mechanical switch control

Check switch control

FAULT: DIFFERENTIAL-LOCK WARNING LAMP IS NOT FUNCTIONING

Possible cause

Remedy

Switch on cylinder fitted too high

Readjust switch

Switch on cylinder defective

Replace switch

Fault in electrical circuit

Check electrical circuit

ǹ 0001

1

8

DIAGNOSIS

Single rear axle 1347

1-2

FAULT: VIBRATIONS IN THE DRIVE LINE

Possible cause

Remedy

Lifted trailing axle causes excessive in
spring-leafed models

-

Limit the trailing axle lifting height, see
chapter “Inspection and adjustment”

-

Install a key between the spring assembly
and the spring seat, see chapter “Inspection
and adjustment”

1

ǹ 0001

8

Single rear axle 1354

DIAGNOSIS

2-1

2. SINGLE REAR AXLE 1354

2.1 FAULT-FINDING TABLE

FAULT: NOISES IN REAR AXLE AND DRIVE ASSEMBLY

Possible cause

Remedy

Oil level too low

Top up oil

Oil with incorrect viscosity

Drain oil and top up

Loosened attachment bolts or broken
differential-lock parts

Drain oil and check drained oil for presence of
pieces of metal

Pinion-bearing play

Adjust and/or replace

FAULT: OIL LEAKAGE

Possible cause

Remedy

Oil level too high

Drain oil

Oil with incorrect viscosity

Drain oil and top up

Leaking oil sealing ring

Replace oil sealing ring

Bleeding system blocked

Clean or replace the bleeding system

Oil leakage between the differential housing
mating surfaces

Clean mating surfaces and apply new sealing
compound

FAULT: DIFFERENTIAL LOCK IS NOT FUNCTIONING

Possible cause

Remedy

No air pressure at engaging cylinder

Check compressed-air system

Defective pneumatic control

Check or replace pneumatic switch

Incorrect setting engaging cylinder

Adjust engaging cylinder

Defective mechanical switch control

Check switch control

FAULT: DIFFERENTIAL-LOCK WARNING LAMP IS NOT FUNCTIONING

Possible cause

Remedy

Defective pressure switch

Replace pressure switch

Fault in electrical circuit

Check electrical circuit

1

ǹ 0001

 

 

 

 

 

 

 

Content   ..  566  567  568  569   ..