Index Chrysler Chrysler Sebring, Stratus sedan, Sebring Convertible - service repair manual 2001-2007 year
|
|
Symptom: DIMMING LEVEL SWITCH INPUT FAILURE When Monitored and Set Condition: DIMMING LEVEL SWITCH INPUT FAILURE When Monitored: Continuously. Set Condition: BCM detects an open or short circuit condition for 10 consecutive seconds on the dimming level switch input. POSSIBLE CAUSES INTERMITTENT CONDITION OPEN CIRCUIT SHORT TO GROUND SHORT TO BATTERY FAILED DIMMER SWITCH BODY CONTROL MODULE TEST ACTION APPLICABILITY 1 Turn the ignition on. t, clear all BCM DTC’s. Actuate the Dimming Level Switch. t, read the DTC information. Does the DRBIII t read: Dimming Level Switch Input Failure? All Yes → Go To 2 No → The condition that caused the symptom is currently not present. Inspect the related wiring for a possible intermittent condition. 2 Disconnect the Junction Block C11 Harness Connector from the front of the junction All Yes → Go To 3 No → Repair the open circuit condition. Perform BODY VERIFICATION TEST - VER 1. 385 INTERIOR LIGHTING |