DLK-262 < SYMPTOM DIAGNOSIS > AUTOMATIC BACK DOOR OPERATION DOES NOT OPERATE 5. CHECK BACK DOOR CLOSURE MOTOR Check back door closure motor. DLK-222, "Diagnosis Procedure" . Is the inspection result normal? YES >> GO TO 6. NO >> Repair or replace the malfunctioning parts. 6. REPLACE AUTOMATIC BACK DOOR CONTROL MODULE 1. Replace automatic back door control module. Refer to DLK-321, "Removal and Installation" . 2. Confirm the operation after replacement. YES >> Inspection End. NO >> Check intermittent incident. Refer to GI-49, "Intermittent Incident" . OPEN FUNCTION INFOID:0000000009175847 Back door auto closure function does not operate when back door opening operations are performed. OPEN FUNCTION : Diagnosis Procedure INFOID:0000000009175848 1. CONFIRM THE OPERATION 1. Turn ON automatic back door main switch. 2. Confirm the operation. YES >> Automatic back door system is normal. NO >> GO TO 2. 2. CHECK AUTOMATIC BACK DOOR MAIN SWITCH Check automatic back door main switch. DLK-209, "Component Function Check" Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace the malfunctioning parts. 3. CHECK BACK DOOR OPENER SWITCH Check back door opener switch. DLK-199, "Component Function Check" Is the inspection result normal? YES >> GO TO 4. NO >> Repair or replace the malfunctioning parts. 4. REPLACE AUTOMATIC BACK DOOR CONTROL MODULE 1. Replace automatic back door control module. Refer to DLK-321, "Removal and Installation" . 2. Confirm the operation after replacement. YES >> Inspection End. NO >> Check intermittent incident. Refer to GI-49, "Intermittent Incident" . CLOSURE FUNCTION INFOID:0000000009175849 Back door auto closure function does not operate when back door closing operations are performed. |