|
|
DLK-258 < SYMPTOM DIAGNOSIS > AUTOMATIC BACK DOOR OPERATION DOES NOT OPERATE AUTOMATIC BACK DOOR OPERATION DOES NOT OPERATE ALL SWITCHES INFOID:0000000009175835 Automatic back door open/close function does not operate using all switches. NOTE: Automatic back door open/close operation condition is extremely complicated. During operating confirmations, reconfirm the list above twice in order to ensure proper operation. Refer to ALL SWITCHES : Diagnosis Procedure INFOID:0000000009175836 1. CHECK DTC WITH AUTOMATIC BACK DOOR CONTROL MODULE Check that DTC is not detected with automatic back door control module. YES >> GO TO 2. NO >> Perform trouble diagnosis relevant to DTC indicated. 2. CHECK BACK DOOR AUTO CLOSURE FUNCTION Check back door auto closure function. YES >> GO TO 3. NO >> Refer to DLK-261, "OPEN/CLOSURE FUNCTION : Diagnosis Procedure" . 3. CHECK POWER SUPPLY AND GROUND CIRCUIT Check automatic back door control module power supply and ground circuit. DLK-117, "Diagnosis Procedure" Is the inspection result normal? YES >> GO TO 4. NO >> Repair or replace the malfunctioning parts. 4. CHECK GROUND CIRCUIT Check automatic back door control module ground circuit. DLK-144, "Diagnosis Procedure" . Is the inspection result normal? YES >> GO TO 5. NO >> Repair or replace the malfunctioning parts. 5. CHECK TOUCH SENSOR LH Check touch sensor LH. DLK-126, "Component Inspection" . Is the inspection result normal? YES >> GO TO 6. NO >> Repair or replace the malfunctioning parts. 6. CHECK TOUCH SENSOR RH Check touch sensor RH. DLK-123, "Component Inspection" . Is the inspection result normal? YES >> GO TO 7. NO >> Repair or replace the malfunctioning parts. 7. REPLACE AUTOMATIC BACK DOOR CONTROL MODULE 1. Replace automatic back door control module. Refer to DLK-321, "Removal and Installation" . 2. Confirm the operation after replacement. YES >> Inspection End. |