DLK-222 < DTC/CIRCUIT DIAGNOSIS > BACK DOOR CLOSURE MOTOR BACK DOOR CLOSURE MOTOR Diagnosis Procedure INFOID:0000000009175784 Regarding Wiring Diagram information, refer to . 1. CHECK BACK DOOR CLOSURE MOTOR INPUT SIGNAL 1. Turn ignition switch OFF. 2. Disconnect back door lock assembly connector. 3. Check voltage between back door lock assembly harness connector and ground. Is the inspection result normal? YES >> Replace back door lock assembly. Refer to DLK-308, "DOOR LOCK : Removal and Installation" NO >> GO TO 2. 2. CHECK BACK DOOR CLOSURE MOTOR CIRCUIT 1. Disconnect automatic back door control module connector. 2. Check continuity between automatic back door control module harness connector and back door lock assembly harness connector. 3. Check continuity between automatic back door control module harness connector and ground. Is the inspection result normal? YES >> Replace automatic back door control module. Refer to DLK-321, "Removal and Installation" . NO >> Repair or replace harness. (+) (–) Condition Voltage (Approx.) Back door lock assembly Connector Terminal D557 1 Ground Back door opener Pressed 16 – 7.8 V 2 Released 0 V Automatic back door control module Back door lock assembly Continuity Connector Terminal Connector Terminal B56 31 D557 1 Yes 38 2 Automatic back door control module Ground Continuity Connector Terminal B56 31 No 38 |