Frelander 2. Manual - part 15

 

  Index      Land Rover     Land Rover Frelander 2 - service repair manual 2006-2010 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  13  14  15  16   ..

 

 

Frelander 2. Manual - part 15

 

 

DTC

Description

Possible Cause

Action

U3000-98 Control module

Component or system over
temperature

Check for additional DTCs and refer to relevant DTC Index,
check/monitor system for re-occurrence

U3003-62 Battery voltage

Mis-match in voltage, of 2
volts or more, between
integrated control module
and CJB

Carry out pinpoint tests associated with this DTC using the
manufacturer approved diagnostic system

General Information - Diagnostic Trouble Code (DTC) IndexDTC: Auxiliary
Heater Control Module (AHCM)

Description and Operation

• NOTE: If a control module or component is suspect and the vehicle remains under manufacturer warranty, refer to the
Warranty Policy and Procedures manual (section B1.2), or determine if any prior approval program is in operation, before
the replacement of a component.

• NOTE: Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the scan
tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra information read by the
manufacturer-approved diagnostic system).

• NOTE: When performing voltage or resistance tests, always use a digital multimeter (DMM) accurate to three decimal
places, and with an up-to-date calibration certificate. W hen testing resistance always take the resistance of the DMM
leads into account.

• NOTE: Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests.

• NOTE: Inspect connectors for signs of water ingress, and pins for damage and/or corrosion.

• NOTE: If DTCs are recorded and, after performing the pinpoint tests, a fault is not present, an intermittent concern may
be the cause. Always check for loose connections and corroded terminals.

Description And Operation

For a detailed description of the fuel fired booster heater contol system, refer to the relevant Description and Operation
section in the workshop manual.
For additional information, refer to: 

Fuel Fired Booster Heater

 (412-02B Auxiliary Climate Control, Description and

Operation).

• NOTE: Where an 'on demand self-test' is referred to, this can be accessed via the 'DTC Monitor' tab on the manufacturers
approved diagnostic system.

DTC

Description

Possible Causes

Action

B1D22-11 Coolant Temperature

Sensor - circuit short
to ground

Fuel fired booster heater
coolant temperature sensor
internal fault

Check and install a new fuel fired booster
heater coolant temperature sensor
Using the manufacturer approved diagnostic
system, record then clear any stored diagnostic
trouble codes then conduct the fuel fired
booster heater operation test (Setup and
configuration/auxiliary heater/operation test)
Check for stored diagnostic trouble codes
Check for correct operation

B1D22-15 Coolant Temperature

Sensor - circuit short
to battery or open

Fuel fired booster heater
coolant temperature sensor
internal fault

Check and install a new fuel fired booster
heater coolant temperature sensor
Using the manufacturer approved diagnostic
system, record then clear any stored diagnostic
trouble codes then conduct the fuel fired
booster heater operation test (Setup and
configuration/auxiliary heater/operation test)
Check for stored diagnostic trouble codes
Check for correct operation

B1D23-13 Overheat Sensor -

circuit open

Fuel fired booster heater
coolant temperature sensor
internal fault

Check and install a new fuel fired booster
heater coolant temperature sensor
Using the manufacturer approved diagnostic
system, record then clear any stored diagnostic
trouble codes then conduct the fuel fired
booster heater operation test (Setup and
configuration/auxiliary heater/operation test)
Check for stored diagnostic trouble codes
Check for correct operation

B1D24-11 Glow Plug - circuit

short to ground

Fuel fired booster heater
glow plug internal fault

Carry out circuit checks, inspect the glow plug
cables and connector. Repair the circuit or check
and install a new fuel fired booster heater glow
plug
 as required For additional information,
refer to: 

Fuel Fired Booster Heater Glow Plug

And Burner Assembly

 (412-02B Auxiliary Climate

Control, Removal and Installation).
Using the manufacturer approved diagnostic
system, record then clear any stored diagnostic
trouble codes then conduct the fuel fired
booster heater operation test (Setup and
configuration/auxiliary heater/operation test)
Check for stored diagnostic trouble codes
Check for correct operation

DTC

Description

Possible Causes

Action

B1D24-15 Glow Plug - circuit

short to battery or
open

Fuel fired booster heater
glow plug internal fault

Carry out circuit checks, inspect the glow plug
cables and connector. Repair the circuit or check
and install a new fuel fired booster heater glow
plug
 as required For additional information,
refer to: 

Fuel Fired Booster Heater Glow Plug

And Burner Assembly

 (412-02B Auxiliary Climate

Control, Removal and Installation).
Using the manufacturer approved diagnostic
system, record then clear any stored diagnostic
trouble codes then conduct the fuel fired
booster heater operation test (Setup and
configuration/auxiliary heater/operation test)
Check for stored diagnostic trouble codes
Check for correct operation

B1D25-11 Heater Fuel Pump -

circuit short to
ground

Heater fuel pump circuit
short to ground
Heater fuel pump failure

Refer to the electrical circuit diagrams and
check the fuel fired booster heater fuel pump
and circuit for short to ground
Repair the circuit or check and install a new fuel
fired booster heater fuel pump as required
For additional information, refer to: 

Fuel Fired

Booster Heater Fuel Pump

 (412-02B Auxiliary

Climate Control, Removal and Installation).
Using the manufacturer approved diagnostic
system, record then clear any stored diagnostic
trouble codes then conduct the fuel fired
booster heater operation test (Setup and
configuration/auxiliary heater/operation test)
Check for stored diagnostic trouble codes
Check for correct operation

B1D25-15 Heater Fuel Pump -

circuit short to
battery or open

Heater fuel pump circuit
short to power, open circuit
Heater fuel pump failure

Refer to the electrical circuit diagrams and
check the fuel fired booster heater fuel pump
and circuit for short to power, open circuit
Repair the circuit or check and install a new fuel
fired booster heater fuel pump as required
For additional information, refer to: 

Fuel Fired

Booster Heater Fuel Pump

 (412-02B Auxiliary

Climate Control, Removal and Installation).
Using the manufacturer approved diagnostic
system, record then clear any stored diagnostic
trouble codes then conduct the fuel fired
booster heater operation test (Setup and
configuration/auxiliary heater/operation test)
Check for stored diagnostic trouble codes
Check for correct operation

B1D26-11 Combustion Air

Blower - circuit short
to ground

Fuel fired booster heater
module failure

Using the manufacturer approved diagnostic
system, record then clear any stored diagnostic
trouble codes then conduct the fuel fired
booster heater operation test (Setup and
configuration/auxiliary heater/operation test)
If the diagnostic trouble code reoccurs check
and install a new fuel fired booster heater
module as required
For additional information, refer to: 

Fuel Fired

Booster Heater

 (412-02B Auxiliary Climate

Control, Removal and Installation).
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the
installation of a new module/component

B1D26-15 Combustion Air

Blower - circuit short
to battery or open

Fuel fired booster heater
module failure

Using the manufacturer approved diagnostic
system, record then clear any stored diagnostic
trouble codes then conduct the fuel fired
booster heater operation test (Setup and
configuration/auxiliary heater/operation test)
If the diagnostic trouble code reoccurs check
and install a new fuel fired booster heater
module as required
For additional information, refer to: 

Fuel Fired

Booster Heater

 (412-02B Auxiliary Climate

Control, Removal and Installation).
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the
installation of a new module/component

B1D26-92 Combustion Air

Blower - performance
or incorrect
operation

Fuel fired booster heater
module failure

Using the manufacturer approved diagnostic
system, record then clear any stored diagnostic
trouble codes then conduct the fuel fired
booster heater operation test (Setup and
configuration/auxiliary heater/operation test)

DTC

Description

Possible Causes

Action

Check for reoccurrence of the diagnostic trouble
code
If the diagnostic trouble code reoccurs check
and install a new fuel fired booster heater
module as required
For additional information, refer to: 

Fuel Fired

Booster Heater

 (412-02B Auxiliary Climate

Control, Removal and Installation).
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the
installation of a new module/component

B1D26-93 Combustion Air

Blower - no
operation

Fuel fired booster heater
module failure

Using the manufacturer approved diagnostic
system, record then clear any stored diagnostic
trouble codes then conduct the fuel fired
booster heater operation test (Setup and
configuration/auxiliary heater/operation test)
Check for reoccurrence of the diagnostic trouble
code
If the diagnostic trouble code reoccurs check
and install a new fuel fired booster heater
module as required
For additional information, refer to: 

Fuel Fired

Booster Heater

 (412-02B Auxiliary Climate

Control, Removal and Installation).
Refer to the warranty policy and procedures
manual, or determine if any prior approval
programme is in operation, prior to the
installation of a new module/component

B1D27-11 Heater Coolant Pump

- circuit short to
ground

Heater coolant pump circuit
short to ground
Heater coolant pump failure

Refer to the electrical circuit diagrams and
check the fuel fired booster heater water pump
and circuit for short to ground
Repair the circuit or check and install a new fuel
fired booster heater water pump as required
For additional information, refer to: 

Fuel Fired

Booster Heater Coolant Pump

 (412-02B

Auxiliary Climate Control, Removal and
Installation).
Using the manufacturer approved diagnostic
system, record then clear any stored diagnostic
trouble codes then conduct the fuel fired
booster heater operation test (Setup and
configuration/auxiliary heater/operation test)
Check for stored diagnostic trouble codes
Check for correct operation

B1D27-15 Heater Coolant Pump

- circuit short to
battery or open

Heater coolant pump circuit
short to power, open circuit
Heater coolant pump failure

Refer to the electrical circuit diagrams and
check the fuel fired booster heater water pump
and circuit for short to power, open circuit
Repair the circuit or check and install a new fuel
fired booster heater water pump as required
For additional information, refer to: 

Fuel Fired

Booster Heater Coolant Pump

 (412-02B

Auxiliary Climate Control, Removal and
Installation).
Using the manufacturer approved diagnostic
system, record then clear any stored diagnostic
trouble codes then conduct the fuel fired
booster heater operation test (Setup and
configuration/auxiliary heater/operation test)
Check for stored diagnostic trouble codes
Check for correct operation

B1D28-11 Fuel Pre-heater -

circuit short to
ground

• NOTE: The pre heat is performed
by the ignition glow plug

Fuel fired booster heater
glow plug internal fault

Carry out circuit checks, inspect the glow plug
cables and connector
Check and install a new fuel fired booster
heater glow plug as required For additional
information, refer to: 

Fuel Fired Booster Heater

Glow Plug And Burner Assembly

 (412-02B

Auxiliary Climate Control, Removal and
Installation).
Using the manufacturer approved diagnostic
system, record then clear any stored diagnostic
trouble codes then conduct the fuel fired
booster heater operation test (Setup and
configuration/auxiliary heater/operation test)
Check for stored diagnostic trouble codes
Check for correct operation

 

 

 

 

 

 

 

Content   ..  13  14  15  16   ..