135
15-MINUTE TIMER -- DITCHING: The 15-minute timer apparently causes really bad fuel economy during those 15
minutes, especially aggravating for owners whose driving patterns happen to have them within those 15 minutes most
of the time they are driving. Craig Sawyers says, “Admittedly, the V12 is thirsty, but a certain amount of that is to do
with the 15-minute timer on the vacuum advance. Before that cuts in I get 14 (UK) mpg. When it cuts out it comes
back to 19-20.” Mike Morrin says, “My weekday commute is only 3.5 miles each way, the thermal switch operates
after about a mile and totally disconnecting the 15 minute circuit gave me a 2 MPG overall improvement.”
If you’re sick of using so much fuel, disconnect the timer! The car will run just fine with full vacuum advance when
cold, it just won’t warm up as quickly. Since the timer energizes the 3-way solenoid valve, the 2-way solenoid valve,
and the supplemental air valve (see page 303) and de-energizes them when the 15 minutes are up, you can merely
disconnect the wires from the timer or the coolant temp switch and the car will never lack vacuum advance again. The
easiest way to disable it is to just pull one of the wires on the thermal switch on the rear end of the right side coolant
manifold. This is obviously easy enough you can try it and see if you like it.
Once you decide to make this change permanent, you can make things neater by removing all of those valves and
plumbing up the vacuum advance system with the same routing that effectively existed after the 15 minutes had
expired. You can also trashcan the timer itself if you want, and replace the coolant sensor with a plug.
The 2-way solenoid valve and the 3-way solenoid valve are involved in killing the vacuum advance at idle during cold
starts, but the purpose of the supplemental air valve is to boost the idle RPM to compensate for the lack of vacuum
advance. Disabling the cold start solenoid valves theoretically eliminates the need for this idle boost (the Auxiliary Air
Valve is intended to provide idle boost for cold starting), but if you find the car idling too slowly when cold you might
consider leaving the supplemental air valve connected and disconnecting the solenoid valves only. In this regard, this
system may serve as a patch for a weak or deteriorating AAV (see page 263).
Also note that, on later cars, the same supplemental air valve was used to boost the idle when the A/C compressor was
engaged. This is a really nice feature, and one might consider keeping the supplemental air valve in place for that
purpose. If your car is an earlier model lacking this A/C idle boost, you might want to wire it up! See page 303.
15-MINUTE TIMER -- MODIFICATION: The only problem with ditching the 15-minute timer is how long the
engine takes to warm up. The vacuum advance makes the engine run efficiently, so it doesn’t generate as much waste
heat. Killing the vacuum makes the engine inefficient so it generates a lot of waste heat and warms up quickly.
Richard Mansell says, “I disconnected mine recently and found that it seemed to take a lot longer to warm up. It is now
reconnected. I may disconnect it again for the summer (if we actually get one this year).” Awwww, little Ricky’s gotta
have his heat!
Craig Sawyers suggests a compromise: “If you unplug the timer and link together the grey and pink/white wires, this
connects the 45°C switch directly to the valves. So the valves will operate until the engine reaches 45°C and then
switch off. I did this with my brother in law's XJS when his module blew.” This is a really neat fix, since it means the
car will get to 45°C in a hurry and then get good fuel economy from then on.
Of course, 45°C isn’t all that hot, so the heater will still not be working as well as some might like. So, there are other
possible fixes. The most obvious would be to replace the coolant temp switch with something with a higher cut-out
temp, like 70°C. It must be stressed that the switch really needs to cut out before the thermostat temp is reached;
otherwise, there’s a chance that the idle vacuum advance will remain disabled indefinitely!
Another idea would be to leave the timer in place but shorten that 15 minutes to something more reasonable. Sawyers
describes how to modify the OEM timer: “The counter is a 14-bit binary counter. The most significant bit is used to
trigger the valves. So you can select a delay of 7.5 minutes by reconnecting diode D1 internally to pin 2 instead of pin
3 on the MC14020 timer chip. Or if you connect to pin 1, you get 3.75 minutes.
Daniel Lethiais elaborates: “You will find inside this unit a small electronic plate with integrated circuits. Near the
HEF4020B is the diode D1. If you want a delay around 4 minute you just have to cut the connexion beetween pin3 to
D1 (with a cutter, knife...) and connect pin 1 to diode D1. It is very easy to do.