controls the roof opening panel. The roof opening panel motor and module are not available 
separately. The roof opening panel may be operated from the roof opening panel switch or the 
global close function. 

Roof Opening Panel Control Switch Operation 

The system operates as follows from the roof opening panel switch: 

 

Press the rear of the switch to the first detent with the roof opening glass in the closed 
position. The roof opening panel glass opens rearward until the roof opening panel 
switch is released or the roof opening panel glass reaches the fully open position.  

o

 

The roof opening panel glass opens rearward until the roof opening panel 
switch is released or the roof opening panel glass reaches the fully open 
position.  

 

Press the rear of the switch to the second detent with the roof opening panel glass in 
the closed position. Activates the 'one touch' open feature. The roof opening panel 
glass will slide rearward until the roof opening panel switch is pressed in any direction 
or the roof opening panel glass reaches the fully open position.  

o

 

Activates the 'one touch' open feature.  

o

 

The roof opening panel glass will slide rearward until the roof opening panel 
switch is pressed in any direction or the roof opening panel glass reaches the 
fully open position.  

 

Press the front of the switch to the first detent with the roof opening panel glass in the 
closed position. The roof opening panel glass will vent up until the roof opening panel 
switch is released or the roof opening panel glass reaches the full vent up position.  

o

 

The roof opening panel glass will vent up until the roof opening panel switch is 
released or the roof opening panel glass reaches the full vent up position.  

 

Press the front of the switch to the second detent with the roof opening panel glass in 
the closed position. The roof opening glass will vent up until the roof opening glass 
reaches the full vent up position or the switch is pressed in any direction.  

o

 

The roof opening glass will vent up until the roof opening glass reaches the full 
vent up position or the switch is pressed in any direction.  

 

Press the front of the switch to the first detent with the roof opening panel glass in the 
fully open position. The roof opening panel glass will slide forward until the roof 
opening panel glass reaches the fully closed position or the switch is released.  

o

 

The roof opening panel glass will slide forward until the roof opening panel 
glass reaches the fully closed position or the switch is released.  

 

Press the front of the switch to the second detent with the roof opening glass in the 
fully open position. The roof opening panel glass will close until the roof opening 
panel switch is pressed in any direction or the roof opening panel glass reaches the 
fully closed position.  

o

 

The roof opening panel glass will close until the roof opening panel switch is 
pressed in any direction or the roof opening panel glass reaches the fully closed 
position.  

 

Press the rear of the switch to the first detent with the roof opening panel glass in the 
vent up position. The roof opening panel glass will close until the roof opening panel 
switch is released or the roof opening panel glass reaches the full closed position.  

o

 

The roof opening panel glass will close until the roof opening panel switch is 
released or the roof opening panel glass reaches the full closed position.  

 

Press the rear of the switch to the second detent with the roof opening panel glass in 
the vent up position. The roof opening panel glass will close until the roof opening 
panel switch is pressed in any direction or the roof opening panel glass reaches the 
fully closed position.  

o

 

The roof opening panel glass will close until the roof opening panel switch is 
pressed in any direction or the roof opening panel glass reaches the fully closed 
position.  

Global Opening And Closing Operation 

The roof opening panel is included in the global open and close operation. This function 
opens or closes the power windows and the roof opening panel automatically. For additional 
information on the global open and close feature for the power windows, refer to <<501-
11>>. The global open function is activated by: 

 

unlocking the drivers door using the remote keyless entry transmitter. Within five 
seconds, press and hold the unlock button.  

 

unlocking the drivers door using the driver door lock cylinder and the key. Hold the 
key in the unlock position.  

The global close function is activated by: 

 

turning the driver door lock cylinder to the lock position and holding.  

Global open and close operation is only available with the ignition in the OFF position and 
the ignition key removed. 
 
When the global open or close operation is selected, the roof opening panel switch is not 
recognized by the roof opening panel control module throughout the operation and five 
seconds after the operation is completed. 
 
Global open and close will operate as follows: 

 

With the roof opening glass in the closed position, activating global open will operate 
the roof opening panel glass to the fully open position.  

 

With the roof opening panel glass in the fully open position, activating global close 
will operate the roof opening panel glass to the closed position.  

 

If a global open is commanded within five seconds of a completed global operation, 
the roof opening panel glass will reverse the previous completed global operation. If 
the roof opening glass was globally closed from the vent position, a global open within 
five seconds would tilt the roof opening panel glass back to the vent position.  

 

If the roof opening panel glass was globally closed from the fully open position, a 
global open within five seconds would slide the roof opening glass back to the fully 
open position.  

 

 

www.

Diagnosis and testing

 

 

Roof Opening Panel   

Principles of operation 

Roof Opening Panel Control Module 

Battery power is continuously supplied to the roof opening panel control module. However, 
the roof opening panel will only operate from the roof opening panel switch with the ignition 
switch with the ignition a switch in the RUN or ACC position. The global open and close 
feature is controlled by two circuits from the REM. The two circuits must be at ground 
potential before the roof opening panel control module will acknowledge the roof opening 
panel switch. When the ignition switch is turned to RUN or ACC, the REM provides ground 
to these circuits. 
 
The roof opening panel control module incorporates soft stops at the end of all travel 
positions. The roof opening panel control module monitors the internal switches to determine 
the roof opening glass position and the soft stops. The internal switches are activated by the 
roof opening panel motor rotation. 
 
The roof opening panel control module supplies the power and ground to the roof opening 
panel motor depending on the ordered function. Power is supplied to the roof opening panel 
for a maximum of 12 seconds. Under normal operation, position is monitored by the roof 
opening panel control module and power is removed from the roof opening panel motor as 
soon as the roof opening panel reaches the commanded position. 

Roof Opening Panel Switch 

Four circuits connect the roof opening panel switch to the roof opening panel control module. 
One circuit is the common return. The other three are control circuits open, close and tilt. The 
roof opening panel control module monitors these lines for voltage fluctuation to determine 
which function was selected. 
 
With the ignition switch in the RUN or ACC position, the roof opening panel supplies a five 
volt reference voltage to three control lines. Activation of the roof opening panel switch 
connects one or more of these lines to the common return which pulls the line low. The roof 
opening panel control module will sense the line or lines being connected to the common line 
and carry out the appropriate function. 
 
The express open function connects the open and tilt circuits to the common return when the 
roof opening panel switch is moved rearward to the second detent position. The operator-
controlled open function connects the open circuit to the common return. The close function 
connects the close circuit to the common causing the roof opening panel to close from a slide 
or vent position. 

Global Open and Close 

Two circuits connect the rear electronics module (REM) to the roof opening panel control 
module for these functions. Global open and close operation for the roof opening panel is 
controlled by one of these two circuits being grounded by the REM. 
 
When the ignition switch is in the RUN or ACC position, the REM grounds both of these 
circuits allowing normal operation of the roof opening panel from the roof opening panel 
switch. Global open and close operation is only available with the ignition in the OFF position 
and the ignition key removed. 
 
When global open or close operation is selected, the roof opening panel switch is not 
recognized by the roof opening panel control module throughout the operation and five 
seconds after the operation is completed. 
 
With the ignition switch in the OFF position, the roof opening panel control module supplies 
a constant voltage to these two circuits. The roof opening panel control module monitors these 
lines for a low state, caused by the REM grounding the line, to determine the ordered global 
function by the REM. 
 
Global open is commanded by the REM grounding control line two. Line one will remain at 
previous voltage. 
 
Global close is commanded by the REM grounding control line one. Line two will remain at 
previous voltage. 
 
If both lines have voltage, the roof opening panel will be inoperative. 

Inspection and Verification 

1 . Verify the customer concern by operating the system.  
 
2 . Visually inspect for obvious signs of mechanical and electrical damage.  

Visual Inspection Chart 

Mechanical  

Electrical  

 

Roof opening panel frame  

 

Roof opening panel glass weatherstrip  

 

Roof opening panel alignment  

 

Motor synchronization  

 

Fuse(s)  

 

Roof opening panel switch  

 

Roof opening panel motor  

 

Wiring harness  

 

Electrical connector(s)  

 
1 . If an obvious cause for an observed or reported concern is found, correct the cause (if 
possible) before proceeding to the next step.  
 
2 . If the concern is not visually evident, verify the Symptom Chart.  