CHARGING THE PLUG-IN HYBRID VEHICLE
Charging Information
Trickle Charge :
Charging Time Information
Normal Charge :
The plug-in hybrid vehicle can be
Normal Charge :
charged by using household elec-
The plug-in hybrid vehicle is
Takes approximately 2 hours 15
tricity. The electrical outlet in your
charged by plugging into a normal
minutes at room temperature. (Can
home must comply with regulations
charger installed in your home or a
be charged to 100%.)
and can safely accommodate the
public charging station. (For further
Voltage / Current (Amps) / Power
• Trickle Charge :
details, refer to the 'Normal
(Watts) ratings specified on the
For charging at home. Please note
Charge'.)
portable charge.
that Trickle Charger is slower than
the Normal Charger.
Charging Types
Charging Inlet
Category
Charging Connector
Charging Outlet
How to Charge
Charging Time
(Vehicle)
Use normal
Approx. 2 hours
Normal
charger installed
15 minutes (to fully
Charge
in homes or public
charge, 100%)
charging station
OAEEQ016020
OLFP0Q5006K
OLFP0Q4057N
For charging at
home. Please note
Trickle
Use household
that Trickle Charger
Charge
current
is slower than the
Normal Charger.
OAEEQ016020
OLFP0Q5006K
OAEEQ016024
• Depending on the condition and durability of the high voltage battery, charger specifications, and ambient
temperature, the time required for charging the high voltage battery may vary.
• Actual charger image and charging method may vary in accordance with the charger manufacturer.
H4
Charging Status
Operation of Charging Indicator Lamp
Details
(1)
(2)
(3)
 (OFF)
 (OFF)
 (OFF)
Not Charged
Blink
 (OFF)
 (OFF)
0~33%
 (ON)
Blink
 (OFF)
Charging
34~66%
 (ON)
 (ON)
Blink
67~99%
 (ON)
 (ON)
 (ON)
Fully charged (100%)(turns OFF in 5 seconds)
Blink
Blink
Blink
Error while charging
OAEEQ016025
Charging the 12 V auxiliary battery
 (OFF)
 (OFF)
Blink
(Aux. Battery Saver+)
When charging the high voltage bat-
Scheduled charging is operating
tery, the charge level can be checked
 (OFF)
Blink
 (OFF)
(turns OFF after 3 minutes)
from outside the vehicle.
H5
CHARGING THE PLUG-IN HYBRID VEHICLE (CONT.)
Charging Connector
When the Charging Connector
• AUTO mode (button indicator on) :
AUTO / LOCK Mode
is Locked
The connector locks when charg-
ing starts. The connector unlocks
LOCK
AUTO
when charging is complete. This
Before charging
O
X
mode can be used when charging
in a public charging station.
While charging
O
O
Finished charging
O
X
LOCK mode (button indicator off) :
The connector locks when the
charging connector is plugged into
the charging inlet. The connector is
OAEEQ016059
locked until all doors are unlocked
by the driver. This mode can be
You may select when the charging
used to prevent charging cable
connector can be locked and
theft.
unlocked in the charging inlet.
- If the charging connector is
Press the
button to change
unlocked when all doors are
between AUTO mode and LOCK
unlocked, but the charging cable
mode.
is not disconnected within 10 sec-
onds, the connector will be auto-
matically locked again.
- If the charging connector is
unlocked when all doors are
unlocked, but all doors are locked
again, immediately, the connector
will be automatically locked again.
H6
Scheduled Charging
(if equipped)
You can set-up a charging sched-
ule for your vehicle using the AVN
or BlueLink application.
Refer to the Multimedia manual or
the BlueLink manual for detailed
information about setting sched-
uled charging.
Scheduled charging can only be
done when using a normal charger
OAEEQ016026
OAEEQ016027
or the portable charger (ICCB: In-
When scheduled charging is set
If you press the scheduled charg-
Cable Control Box).
and the normal charger or the
ing deactivation
(
) button to
portable charger (ICCB: In-Cable
immediately charge the battery,
Control Box) is connected for
charging must be initiated 3 min-
charging, the indicator lamp in the
utes after the charging cable has
middle blinks
(for
3 minutes) to
been connected.
indicate that scheduled charging is
When you press the scheduled
set.
charging deactivation
(
) button
When scheduled charging is set,
for immediate charging, the sched-
charging is not initiated immediate-
uled charge setting is not com-
ly when the normal charger or
pletely deactivated. If you need to
portable charger (ICCB: In-Cable
completely deactivate the sched-
Control Box) is connected. When
uled charge setting, use the AVN
immediate charging is required,
to finalize the deactivation.
use the AVN to deactivate the
Refer to "Normal Charge or Trickle
scheduled charge setting or press
Charge" for details about connecting
scheduled charging deactivation
the normal charger and the portable
(
) button.
charger (ICCB: In-Cable Control Box).
H7
CHARGING THE PLUG-IN HYBRID VEHICLE (CONT.)
Charging Precautions
WARNING
WARNING
■ Normal Charger
Electromagnetic waves that
Be careful not to touch the
are generated from the charg-
charging connector, charging
er can seriously impact med-
plug, and the charging inlet
ical electric devices such as
when connecting the cable to
an implantable cardiac pace-
the charger and the charging
maker.
inlet on the vehicle.
When using medical electric
Comply with the following in
devices such as an implantable
order to prevent electrical
cardiac pacemaker, make sure
shock when charging:
to ask the medical team and
- Use a waterproof charger.
OLFP0Q4057N
manufacturer whether charg-
- Be careful when touching
ing your electric vehicle will
Actual charger image and charg-
the charging connector and
impact the operation of the
ing method may vary in accor-
charging plug with your
medical electric devices such
dance with the charger manufac-
hands wet, or when standing
as an implantable cardiac
turer.
in water or snow while con-
pacemaker.
necting the charging cable.
Check to make sure there is
- Be careful when there is
no water or dust on the charg-
lightning.
ing cable connector and plug
before connecting to the
- Be careful when the charg-
charger and charging inlet.
ing connector and plug is
Connecting while there is
wet.
water or dust on the charging
cable connector and plug may
cause a fire or electric shock.
H8
Normal Charge
WARNING
CAUTION
■ Normal Charger
Immediately stop charging
Always keep the charging con-
when you find abnormal
nector and charging plug in
symptoms (odor, smoke).
clean and dry condition. Be
Replace the charging cable if
sure to keep the charging
cable in a condition where
the cable coating is damaged
to prevent electrical shock.
there is no water or moisture.
When connecting or removing
Make sure to use the designat-
the charging cable, make sure
ed charger for charging the
to hold the charging connec-
electric vehicle. Using any
tor handle and charging plug.
other charger may cause fail-
ure.
OLFP0Q4057N
If you pull the cable itself
(without using the handle), the
Before charging the battery,
Actual charger image and charg-
internal wires may disconnect
turn the vehicle OFF.
ing method may vary in accor-
or get damaged. This may lead
When the vehicle is switched
dance with the charger manufac-
to electric shock or fire.
OFF while charging, the cool-
turer.
ing fan inside the motor com-
partment may automatically
operate. Do not touch the cool-
ing fan while charging.
Be careful not to drop the
charging connector. The
charging connector can be
damaged.
H9
CHARGING THE PLUG-IN HYBRID VEHICLE (CONT.)
How to Connect Normal
Charger
1. Depress the brake pedal and
apply the parking brake.
2. Turn OFF all switches, shift to P
(Park), and turn OFF the vehicle.
OAEEQ016031
5. Hold the charging connector han-
dle and connect it to the vehicle
normal charging inlet. Push the
connector until you hear a "click-
OAEEQ016030
ing" sound. If the charging con-
3. Press center edge of the charging
nector and charging terminal are
door to open the charging door.
not connected properly, this may
cause a fire.
i
Information
The charging door opens only when
the door is unlocked.
4. Check if there is dust on the
charging connector and charging
inlet.
H10
■ Normal Charger
i
Information
Charging connector AUTO/LOCK
mode
The charging connector is locked in
the inlet at a different period accord-
ing to which mode is selected.
• LOCK mode : The connector locks
when the charging connector is
plugged into the charging inlet.
• AUTO mode : The connector locks
when charging starts.
OLFP0Q4057N
OAEEQ016032
For more details, refer to "Charging
6. Connect the charging plug to the
7. Check if the charging indicator
Connector AUTO/LOCK Mode" in
electric outlet at a normal charg-
light of the high voltage battery on
this chapter.
ing station to start charging.
the instrument cluster is turned
ON. Charging is not done when
the charging indicator lamp is
OFF.
When the charging connector and
charging plug are not connected
properly, reconnect the charging
cable to charge.
H11
CHARGING THE PLUG-IN HYBRID VEHICLE (CONT.)
i
Information
i
Information
Even though charging is possible
Depending on the condition and dura-
with the Engine Start/Stop button in
bility of the high voltage battery,
the ON/START position, for your
charger specifications, and ambient
safety, start charging when the
temperature, the time required for
Engine Start/Stop button is in the
charging the battery may vary.
OFF position and the vehicle shifted
to P
(Park). After charging has
started, you can use electrical com-
ponents such as the radio by press-
ing the Engine Start/Stop button to
OAEPH047193N
the ACC or ON position.
8. After charging has started, the
During normal charging, the radio
estimated charging time is dis-
reception may be bad.
played on the instrument cluster
Moving the shift lever from P (Park)
for about 1 minute.
to R
(Reverse)/N
(Neutral)/D
If you open the driver seat door
(Drive) stops the charging process.
while charging, the estimated
To restart the charging process,
charging time is also displayed on
move the shift lever to P (Park),
the instrument cluster for about 1
place the Engine Start/Stop button
minute.
to the OFF position, and disconnect
When scheduled charging is set,
the charging cable. Then, connect
the estimated charging time is dis-
the charging cable.
played as "--".
H12
Checking Charging Status
Operation of Charging Indicator Lamp
Details
(1)
(2)
(3)
 (OFF)
 (OFF)
 (OFF)
Not Charged
Blink
 (OFF)
 (OFF)
0~33%
 (ON)
Blink
 (OFF)
Charging
34~66%
 (ON)
 (ON)
Blink
67~99%
 (ON)
 (ON)
 (ON)
Fully charged (100%) (turns OFF in 5 seconds)
Blink
Blink
Blink
Error while charging
OAEEQ016025
Charging the 12 V auxiliary battery
 (OFF)
 (OFF)
Blink
(Aux. Battery Saver+)
When charging the high voltage bat-
tery, the charge level can be checked
Scheduled charging is operating
 (OFF)
Blink
 (OFF)
from outside the vehicle.
(turns OFF after 3 minutes)
H13
CHARGING THE PLUG-IN HYBRID VEHICLE (CONT.)
How to Disconnect Normal
i
Information
Charger
To prevent charging cable theft, the
■ Normal Charger
charging connector cannot be discon-
nected from the inlet when the doors
are locked. Unlock all doors to discon-
nect the charging connector from the
inlet.
However, if the vehicle is in the charg-
ing connector AUTO mode, the charg-
ing connector automatically unlocks
from the inlet when charging is com-
OAEEQ016033
pleted.
2. Hold the charging connector han-
For more details, refer to "Charging
dle and pull it while pressing the
OLFP0Q4057N
Connector AUTO/LOCK Mode" in
release button (1).
1. When charging is complete,
this chapter.
remove the charging plug from the
electrical outlet of the normal
charging station.
H14
Unlock Charging Connector in
Trickle Charge
Emergency
■ Portable Charger
OAEEQ016042
OAEPHQ016060
(1) Code and Plug (Code set)
OAEEQ016034
If the charging connector does not
(2) Control Box
disconnect due to battery discharge
3. Make sure to completely close the
(3) Charging Cable and Charging
and failure of the electric wires, open
charging door.
Connector
the hood and slightly pull the emer-
gency cable. The charging connector
will then disconnect.
Trickle Charge can be used when
Normal Charge is not available by
using household electricity.
H15
CHARGING THE PLUG-IN HYBRID VEHICLE (CONT.)
How to set the charge level of
6. When setting the charge level is
the portable charger
complete, start charging accord-
ing to the trickle charge proce-
dure.
Plug
Electric Outlet
OAEEQ018083
4. Press the button (1) on the back of
the control box for more than 1
OAEE046506N
second to adjust the charge level.
1. Check the rated current of the
(Refer to charging cable type and
electric outlet prior to connecting
example for setting the charge
the plug to the outlet.
level.)
2. Connect the plug to a household
5. The display window on the control
electric outlet.
box changes from H and M to L
3. Check the display window on the
every time you press the button
control box.
(1).
H16
❈ Example for setting the ICCB charge level
How to Connect Portable
(The example is only for reference and may vary according to the sur-
Charger (ICCB: In-Cable Control
rounding environment.)
Box)
Outlet current
ICCB charge level
Control box display window
14-16A
12A
13-12A
10A
11-10A
8A
Plug
Electric Outlet
9-8A
6A
OAEE046506N
1. Connect the plug to a household
electric outlet.
H17
CHARGING THE PLUG-IN HYBRID VEHICLE (CONT.)
OAEEQ016043
OAEEQ016031
2. Check if the power lamp (green)
7. Hold the charging connector han-
illuminates on the control box.
dle and connect it to the vehicle
normal charging inlet. Push the
3. Depress the brake pedal and
OAEEQ016030
connector until you hear a "click-
apply the parking brake.
5. Press center edge of the charging
ing" sound. If the charging con-
4. Turn OFF all switches, shift to P
door to open the charging door.
nector and charging terminal are
(Park), and turn OFF the vehicle.
not connected properly, this may
cause a fire.
i
Information
The charging door opens only when
the door is unlocked.
6. Check if there is dust on the
charging connector and charging
inlet.
H18
i
Information
Charging connector AUTO/LOCK
mode
The charging connector is locked in
the inlet at a different period accord-
ing to which mode is selected.
• LOCK mode : The connector locks
when the charging connector is
plugged into the charging inlet.
• AUTO mode : The connector locks
when charging starts.
OAEEQ016045
OAEEQ016032
For more details, refer to "Charging
8. Charging starts automatically
9. Check if the charging indicator
Connector AUTO/LOCK Mode" in
(charging lamp blinks).
light of the high voltage battery on
this chapter.
the instrument cluster is turned
ON. Charging is not done when
the charging indicator lamp is
OFF.
When the charging connector is
not connected properly, reconnect
the charging cable to charge it
again.
H19
CHARGING THE PLUG-IN HYBRID VEHICLE (CONT.)
i
Information
i
Information
Even though charging is possible
Depending on the condition and dura-
with the Engine Start/Stop button in
bility of the high voltage battery,
the ON/START position, for your
charger specifications, and ambient
safety, start charging when the
temperature, the time required for
Engine Start/Stop button is in the
charging the battery may vary.
OFF position and the vehicle shifted
to P (Park).
After charging has started, you can
use electrical components such as
the radio by pressing the Engine
OAEPH047193N
Start/Stop button to ACC or ON
10. After charging has started, the
position.
estimated charging time is dis-
Moving the shift lever from P (Park)
played on the instrument cluster
to R
(Reverse)/N
(Neutral)/D
for about 1 minute. If you open
(Drive) stops the charging process.
the driver seat door while charg-
To restart the charging process,
ing, the estimated charging time
move the shift lever to P (Park),
is also displayed on the instru-
place the Engine Start/Stop button
ment cluster for about 1 minute.
to the OFF position, and disconnect
When scheduled charging is set,
the charging cable. Then, connect
the estimated charging time is
the charging cable.
displayed as "--".
H20

 

 

 

 

 

 

 

Content   ..  30  31  32  33   ..