ETACS (ELECTRONIC TIME AND ALARM CONTROL SYSTEM)
BE -69
6)
In LIGHT ON state, in case of the AUTO LIGHT
SENSOR value is the input value of the LIGHT
OFF, LIGHT shall be OFF after 2.5 ± 0.2sec.
7)
If the SENSOR value is the input value of the
TAIL LAMP ON, then TAIL LAMP RELAY shall be
ON only, and if it is the input value of the HEAD
LAMP ON, then HEAD LAMP HIGH RELAY shall
be ON so that HEAD LAMP HIGH can be con-
trolled by TAIL LAMP RELAY, HEAD LAMP RE-
LAY, and multifunction (M/F) SW.
8)
In the condition of LIGHT ON, when AUTO LIGHT
SW is ON, HEAD LAMP RELAY shall be ON im-
mediately, and when AUTO LIGHT SW is OFF,
LIGHT shall be OFF immediately.
The LIGHT ON value of the AUTO LIGHT SEN-
SOR shall be complied with the table below.
TAIL LAMP
HEAD LAMP
ON
0.81 ± 0.05V
0.81 ± 0.05V
OFF
1.41 ± 0.05V
1.41 ± 0.05V
ON
OFF
0V
0.81V
0.41V
SENSOR
VALUE
TAIL LAMP &
HEAD LAMP
CONDITION
SCMBE6159L
9)
The time chart according to filtering time and sen-
sor for each applicable area shall be as follow.
AUTO SW
ON
OFF
TAIL LAMP
CONDITION
ON
OFF
HEAD LAMP
RELAY
ON
OFF
TAIL RELAY
ON
OFF
HEAD LAMP
HIGH RELAY
ON
OFF
IGN 1
ON
OFF
T2
T1
SCMBE6902L
T1 : 2.5±0.2s, T2 : 2.5±0.2s
6.
DAYTIME RUNNING LIGHT
In the case of DRL EUROPE specification, by elim-
inating the SHUNT between the TAIL LAMP RELAY
and the INTERIOR LAMP, the interior lamp is con-
trolled by the DRL RALY.
If the IGN2 & ALT "L" are ON, the Tail Lamp RELAY
and the Head Lamp LOW RELAY shall be ON ;
If TAIL LAMP LOW RELAY is ON by the TAIL SW, the
DRL function shall be canceled.
IGN 2
ON
OFF
ALT'L
ON
OFF
TAIL SW
ON
OFF
TAIL RELAY
ON
OFF
HEAD LAMP
SW
ON
OFF
DRL REALY
ON
OFF
HEAD LAMP
RELAY
ON
OFF
SCMBE6903L