397
valves to judge the breakdown of the refrigeration system. The inspection shall be made when the air
temperature is between 30 ~35oC and the engine speed is 2000r/min. The fan wind speed is adjusted to the
high gear and the temperature is adjusted to the Max. refrigerating gear. The normal condition is that: the
pressure at the high-pressure side is 1.2Mpa ~ 1.8Mpa and that at the low-pressure side is 0.15 Mpa ~
0.20Mpa; the system may have a failure if it is out of this scope. 7). Other inspection methods
(1) Condenser: the thermometer is used for thermometer under normal operation. When the condenser air-in
temperature is about 35oC, the air-out temperature shall be about 55oC.
(2) Continual reduction of the air volume at the air outlet means the frosting on the evaporator surface.
(3) Dry reservoir: inconsistency of the temperature on upper and lower side of the dry reservoir shell means
there is the block inside the dry reservoir.
Maintenance and diagnoses of electronic power-assisted steering system
No.291 Line inspection of "EPS" indicating lamp (the "EPS" indicator
does not light up when the ignition switch is opened)
1. Battery
2. Main fuse
3. Ignition switch
4. Circuit fuse (15A)
5. Control module
6. EPS lamp
7. Main fuse
8. Control box socket
9. Connector
Step Operation
Yes
No
1
Are the main fuse and the line fuse in good condition
or not ?
Go to step 2
The main fuse and the line fuse is
broken
2
1. Turn on the ignition switch
2. Inspect the voltage between the terminal "A6"
and the module case earthing
3、Is it the battery voltage?
Go to step 3
“B/W” wire is broken or short circuit
3
1. Check the voltage between the terminal "A8" and
the module case earthing
2. Is it the battery voltage?
Go to step 4
"B/R" wire is broken or short circuit
4
1. Turn off the ignition switch and disconnect the
connector 8 from the control module
2. Disconnect the body ground terminal "A3" on the
connector "8" body
3. Turn on the ignition switch again, is the "EPS"
lamp light up?
Go to step 5
The bulb is burnt out or the "V/G" wire is
broken
5
1. Is the connection between the connector "8" and
the control module firm?
Terminal “A6”,“A7”
" A3 " or " A8 " is in
poor contact; the
control module case
is in poor earthing;
"B" wire
+12V is broken
Poor connection