содержание .. 60 61 62 63 64 65 66 67 68 ..
Geely Diagnosis Flow. Manual part - 67
265 Malfunction Cause Solution Power source circuit Inspect +B and GND, which normal value shall be 10V to 14V. When ACC CD-player power switch ① Check the power switch on CD panel; operate the power switch by hand, if there is no response then replace the CD-player CD-player fails to Internal CD-player power ④ Check the voltage of internal CD-player power source end, if the value is between 10~14V as normal, then replace the CD-player assembly
No. 191 CD-player keeps soundless under all modes Malfunction Cause Solution ① CD-player power source malfunction Inspect +B and GND, which normal value shall be 10V to 14V. When ACC and ② Loudspeaker malfunction Check whether the appearance of loudspeaker is damaged, as well as the coil ③ Wires and connector Check loudspeaker and CD-player connection whether there is open/short CD-player keeps ④ CD-player sound controller damaged Check whether CD-player sound controller is damaged, and track adjustment
CD-player fails to work when activating External CD-player power source CD-player switch Internal CD-player power source circuit Abnormal Abnormal Abnormal Inspect the circuit and replace the fuse Replace CD assembly Replace CD assembly Normal Normal |