Geely EC718, EC718RV, EC715, EC715RV. Manual part - 412

 

  Главная      Geely     Geely Emgrand EC718, EC718RV, EC715, EC715RV. Workshop Manual year 2009

 

поиск по сайту          

 

 

 

 

 

 

 

 

 

 

 

 

 

 

содержание   ..   410  411  412  413  ..

 

 

Geely EC718, EC718RV, EC715, EC715RV. Manual part - 412

 

 

11.5.5 Disassemble View
11.5.5.1 Disassemble View

Window Regulator Assembly

3

1

2

FE11-2006b

Legend

1. Window Motor
2. Window Regulator Rail

3. Electric Window

Body Electric

Glasses / Windows / Mirrors

11-161

Outside Rearview Mirror Assembly

1

2

3

4

5

FE11-2007b

Legend

1. Electric Outside Rearview Mirror Turn Signal Lamp
2. Outside Rearview Mirror Cover
3. Outside Rearview Mirror Adjust Motor Bracket
4. Outside Rearview Mirror Adjust Motor

5. Outside Rearview Mirror Adjust Motor Glass (With

Heating Wire)

11-162

Glasses / Windows / Mirrors

Body Electric

11.5.6 Schematic
11.5.6.1 Schematic

Schematic With Express Down (If Equipped)

Window Switch: Up/Down/Automatic

To BCM

Protective 

Circuit

Relay

Input 

Circuit

Hall IC

FE11-2008b

Body Electric

Glasses / Windows / Mirrors

11-163

11.5.7 Diagnostic Information and Procedures
11.5.7.1 Diagnosis Description

Refer to

11.5.2

 

Description and Operation

get familiar with the system functions and operation before start system diagnostics, so

that it will help to determine the correct diagnostic steps, more importantly, it will also help to determine whether the customer
described situation is normal.

11.5.7.2 Visual Inspection

Check installed aftermarket equipments that may affect the power windows and power mirrors operations.

Check the easy to access system components to identify whether there is a significant damage or potential malfunction.

Check whether the window initialization failed.

11.5.7.3 Control Module Diagnostic Information

Power window control module reports the following failures through the LIN bus:

Motor / Relay Malfunction

Hall Sensor Malfunction

Thermal Protection Triggered

Up Button Is Pressed

Down Button Is Pressed

11.5.7.4 Glass Regulator Initialization (If Window Express Down Feature Is Available)

To initialize the system, the glass must be up all the way to the top, and the switch is pressed to lift the window glass until the
control module stops the glass motor (within 1s after the glass reaches the top). Each time the system lost initialization, repeat
these steps to restore the window express down function.

Initialization, all system functions must be operational.

Initialization, the control module voltage should not drop to below 9 V.

When the control module supply voltage drops momentarily, but the voltage is still higher than 6V, the initialization is effective.

Every time the glass is lift to the top till stop using automatic mode (at the top position); system will obtain the latest top position
and overwrite the previous value to calculate the top position.

Note

Only when the new value is in the calibrated value range, it overwrites the original value, otherwise the control
module will ignore the new value.

If the initialization process has not been implemented or have been lost, system does not provide automatic up,
express down and comfort closing function. Manual up, down and auto-down feature can be operated.

In the following circumstances, the initialization will be lost (If window express down is available is equipped)

Power supply is cut off.

When the glass is moving up, the power supply voltage drops below 6 V.

Control module can not detect logical Hall sensor signals.

Window glass moves to a location outside the operating range.

11-164

Glasses / Windows / Mirrors

Body Electric

 

 

 

 

 

 

 

 

содержание   ..   410  411  412  413  ..