414-03B-32 414-03B-32 High Voltage/Traction Battery — Nickel Metal Hydride DIAGNOSIS AND TESTING (Continued) PINPOINT TEST A: DTC C1839 LEAKAGE FAULT TEST STEP ACTION TO TAKE NOTE: If there is no continuity between the indicated battery module and No = REPLACE the contactor chassis ground, check for continuity between chassis ground and the box. positive (+) posts of the two battery modules before and after the indicated battery module. • With key OFF, disconnect BCM C1865 and C1866, and check for continuity between the positive (+) post of the indicated battery module and chassis ground. • Is there continuity? A29 CHECK FOR CURRENT LEAKAGE IN HIGH-VOLTAGE NEGATIVE BUS (TB-) (INSIDE TRACTION BATTERY SUPPORT TRAY) NOTE: The BCM active command CHARGER must be sent before the Yes = GO to A30 (leakage is in BCM active command NEG MAIN is sent. contactor box or battery • With key ON, enter BCM active command mode CONTACTOR module voltage sense lines). OUTPUT CONTROL, monitor BCM PID LKRESB-, and set the active command CHARGER to CLOSE. • Set the active command NEG MAIN to OPEN. No = GO to A32. • Wait approximately 50 seconds. • Does the LKRESB- PID indicate less than 50,000 ohms? A30 CHECK FOR CURRENT LEAKAGE IN BATTERY MODULE VOLTAGE SENSE LINES • With key ON, monitor BCM PID LEAK ID and note the indicated Yes = REPLACE high-voltage battery module. harness (10B694) and/or the high-voltage harness (14A280) in question. NOTE: If there is no continuity between the indicated battery module and No = GO to A31. chassis ground, check for continuity between chassis ground and the positive (+) posts of the two battery modules before and after the indicated battery module. • With key OFF, disconnect BCM C1865 and C1866, and check for continuity between the positive (+) post of the indicated battery module and chassis ground. • Is there continuity? A31 CHECK FOR CURRENT LEAKAGE IN CONTACTOR BOX • With key OFF, disconnect the negative contactor box cable leading to the Yes = REPLACE the BCM. traction battery 250A high-voltage fuse. NOTE: The BCM active command CHARGER must be sent before the No = REPLACE the contactor BCM active command NEG MAIN is sent. box. • With key ON, enter BCM active command mode CONTACTOR OUTPUT CONTROL, monitor BCM PID LKRESB-, and set the active command CHARGER to CLOSE. • Set the active command NEG MAIN to OPEN. • Wait approximately 50 seconds. • Does the LKRESB- PID indicate less than 50,000 ohms? A32 CHECK FOR CURRENT LEAKAGE IN TRACTION BATTERY SUPPORT TRAY, TRACTION INVERTER MODULE (TIM), MOTOR/TRANSAXLE, OR IN THE AUXILIARY NEGATIVE BUS FOR THE HIGH-VOLTAGE AUXILIARY LOAD COMPONENTS • With key OFF, disconnect high-voltage auxiliary load in-line C1935 on Yes = the traction battery support tray. contactor box, TIM, or traction motor). (Continued) |