414-03B-24 414-03B-24 High Voltage/Traction Battery — Nickel Metal Hydride DIAGNOSIS AND TESTING (Continued) PINPOINT TEST A: DTC C1835 CURRENT SENSE CIRCUIT FAILURE TEST STEP ACTION TO TAKE No = GO to A9. WARNING: The traction battery contains high-voltage components and wiring. High-voltage insulated safety gloves and face shield must be worn when carrying out the following steps. Failure to follow this warning may result in severe personal injury or death. • Connect Traction Battery High-Voltage Service Cord to traction battery support tray in-line C1935F and in-line C1935M. • Connect Traction Battery Low-Voltage Service Cord to traction battery support tray in-line C1939F and in-line C1939M. • Connect 104-Pin Breakout Box (BOB) to BCM C1986, C1987 using the BCM/TIM BOB Adapter Cable and Overlay; leave the BCM disconnected. • With key ON, measure the voltage between BOB pin A15 and ground (BOB pin A33). • Is the voltage between 5 and 8 volts? A9 CHECK CIRCUITS 3602 (T/Y) AND 3706 (DB) FOR OPEN(S) • With key OFF, disconnect contactor box C1982 and measure the Yes = GO to A10. resistance of the T/Y wire between pin 23 on contactor box C1982 and BOB pin B1. • With key OFF, measure the resistance of the DB wire between pin 15 on No = REPAIR the wire(s) in contactor box C1982 and BOB pin A15. question. • Are the resistances less than 5 ohms? A10 CHECK CIRCUIT 3706 (DB) FOR SHORT TO GROUND • With key OFF, measure the resistance between BOB pin A15 and ground Yes = GO to A11. (BOB pin A33). • Is the resistance greater than 10,000 ohms? No = REPAIR the DB wire. A11 CHECK CIRCUIT 3706 (DB) FOR SHORT TO POWER • With key ON, measure the voltage between BOB pin A15 and ground Yes = REPAIR the DB wire. (BOB pin A33). • Is the voltage greater than 0 volts? No = REPLACE the contactor box. A12 CHECK CURRENT SENSE CONTROL DISABLE SIGNAL • Remove the traction battery and connect Traction Battery High-Voltage Yes = GO to A13. Lockout and Diagnostic Tool to the traction battery high-voltage two-pin C3994M. No = WARNING: The traction battery contains high-voltage components and wiring. High-voltage insulated safety gloves and face shield must be worn when carrying out the following steps. Failure to follow this warning may result in severe personal injury or death. • Connect Traction Battery High-Voltage Service Cord to traction battery support tray in-line C1935F and in-line C1935M. • Connect Traction Battery Low-Voltage Service Cord to traction battery support tray in-line C1939F and in-line C1939M. • Connect 104-Pin Breakout Box (BOB) to BCM and BCM C1986, C1987 using the BCM/TIM BOB Adapter Cable and Overlay. • Enter BCM active command mode BCM PACKETED COMMANDS, set the active command CURRENT S to DISABLE, and measure the voltage between BOB pin B22 and ground (BOB pin A33). • Is the voltage greater than 7.5 volts? A13 CHECK CURRENT SENSE CONTROL ENABLE SIGNAL • Set the active command CURRENT S to ENABLE and measure the Yes = System OK. CHECK wiring voltage between BOB pin B22 and ground (BOB pin A33). for intermittent connections. • Is the voltage less than 1 volt? No = (Continued) |