414-03A-12 414-03A-12 High Voltage/Traction Battery DIAGNOSIS AND TESTING (Continued) PINPOINT TEST A: DTC B1676 BATTERY PACK VOLTAGE OUT OF RANGE TEST STEP ACTION TO TAKE • With key OFF, disconnect traction battery support tray in-line C1939 and Yes = GO to A3. connect 104-Pin Breakout Box (BOB) to traction battery support tray in-line C1939M using Traction Battery Low-Voltage Service Cord; do not connect Traction Battery Low-Voltage Service Cord to in-line C1939F. • With key OFF, measure the resistance between BOB pin 65 and ground. No = REPAIR the BK wire. • Is the resistance less than 5 ohms? A3 CHECK CIRCUIT 57 (BK) FOR OPEN • Disconnect the BOB from in-line C1939M and remove the traction Yes = REPLACE the contactor battery. box. No = REPAIR the BK wire. WARNING: The traction battery contains high-voltage components and wiring. High-voltage insulated safety gloves and face shield must be worn when performing the following steps. Failure to follow this warning may result in severe personal injury or death. • Connect BOB to traction battery support tray in-line C1939F using Traction Battery Low-Voltage Service Cord. • With key OFF, disconnect contactor box C1982 and measure the resistance between pin 8 (BK wire) on contactor box C1982 and BOB pin 65. • Is the resistance less than 5 ohms? A4 CHECK STATUS OF HIGH-VOLTAGE POWER TO TIM • With key ON, monitor TIM PID BAT PV. Yes = System OK. CHECK wiring for intermittent connections. • Turn the ignition key to the START position. No = If less than 50 volts, GO to • Does the BAT PV PID indicate between 50 and 385 volts? A5 CHECK MAIN CONTACTOR RELAY NOTE: The active command PRECHG IN must be sent before sending the Yes = GO to A6. active command POS MAIN. If not, New Generation STAR (NGS) Tester will indicate UNABLE TO PERFORM TEST/FUNCTION. • Enter the TIM active command mode CONTACTOR OUTPUT CONTROL, monitor the TIM PID BAT PV, and set the active commands PRECHG IN and POS MAIN to CLOSE. • Set the active command PRECHG IN to OPEN. No = • Does the BAT PV PID indicate less than 50 volts? A6 CHECK TIM MAIN CONTACTOR CONTROL SIGNAL TO CONTACTOR BOX AT TRACTION BATTERY SUPPORT TRAY • With key OFF, disconnect traction battery support tray in-line C1939 and Yes = connect 104-Pin Breakout Box (BOB) to traction battery support tray in-line C1939F and in-line C1939M using Traction Battery Low-Voltage Service Cord. • Turn the ignition key to the START position and measure the voltage No = GO to A7. between BOB pin 23 and ground (BOB pin 65). • Is the voltage greater than 10 volts? A7 CHECK CIRCUIT 3986 (DG) BETWEEN TIM AND TRACTION BATTERY SUPPORT TRAY FOR OPEN • With key OFF, disconnect TIM C4998 and measure the resistance of the Yes = DG wire between pin 8 on TIM C4998 and BOB pin 23. • Is the resistance less than 5 ohms? No = REPAIR the DG wire. (Continued) |