414-03A-8 414-03A-8 High Voltage/Traction Battery DIAGNOSIS AND TESTING (Continued) PINPOINT TEST A: DTC C1862 CONTACTOR CIRCUIT FAILURE TEST STEP ACTION TO TAKE • Remove the traction battery and connect Traction Battery High-Voltage No = REPLACE the contactor Lockout and Diagnostic Tool to traction battery high-voltage two-pin box. C3994M. WARNING: The traction battery contains high-voltage components and wiring. High-voltage insulated safety gloves and face shield must be worn when performing the following steps. Failure to follow this warning may result in severe personal injury or death. • Connect Traction Battery High-Voltage Service Cord to traction battery support tray in-line C1935F and in-line C1935M. • Connect BOB to traction battery support tray in-line C1939F using Traction Battery Low-Voltage Service Cord; do not connect Traction Battery Low-Voltage Service Cord to in-line C1939M. • With key OFF, disconnect contactor box C1982. • With key ON, measure the voltage between BOB pin 17 and ground (BOB pin 65). • Is the voltage greater than 0 volts? A13 CHECK AUXILIARY CONTACTOR RELAY FEEDBACK STATUS • With key ON, monitor IAA module AUXCN I. Yes = REPLACE the IAA module. • Does the AUXCN I PID indicate ENABLED? No = System OK. CHECK wiring for intermittent connections. A14 CHECK AUXILIARY CONTACTOR RELAY STATUS SIGNAL (OPEN FAULT) • Connect 104-Pin Breakout Box (BOB) to IAA module and IAA module Yes = System OK. CHECK wiring C1945. for intermittent connections. • Enter IAA module active command mode AUXILIARY SYSTEM No = GO to A15. CONTROL, set the active command AUX CONT to CLOSE, and measure the voltage between BOB pin 26 and ground (BOB pin 80). • Is the voltage greater than 10 volts? A15 CHECK AUXILIARY CONTACTOR RELAY CONTROL SIGNAL (OPEN FAULT) • Enter IAA module active command mode AUXILIARY SYSTEM Yes = CONTROL, set the active command AUX CONT to CLOSE, and measure the voltage between BOB pin 42 and ground (BOB pin 80). • Is the voltage greater than 10 volts? No = GO to A16. A16 CHECK CIRCUIT 3998 (GY) FOR SHORT TO GROUND • Disconnect BOB from IAA module; leave BOB connected to IAA Yes = REPLACE the IAA module. module C1945. • With key OFF, measure the resistance between BOB pin 42 and ground No = GO to A17. (BOB pin 80). • Is the resistance greater than 10,000 ohms? A17 CHECK CIRCUIT 3998 (GY) BETWEEN IAA MODULE AND TRACTION BATTERY SUPPORT TRAY FOR SHORT TO GROUND • With key OFF, disconnect traction battery support tray in-line C1939. Yes = REMOVE the traction battery and REPAIR the GY wire between the contactor box and in-line C1939F. • With key OFF, measure the resistance between BOB pin 42 and ground No = REPAIR the GY wire (BOB pin 80). between the IAA module • Is the resistance greater than 10,000 ohms? and in-line C1939M. (Continued) |